Owner's Manual TEMP142 / TEMP142CX (2HP) & TEMP143 / TEMP143CC (3HP)

Similar documents
OWNER S MANUAL #DC2000B #DC2000BCF

OWNER S MANUAL #DC2000Y #DC2000YCF 2 HP, 1500 CFM DUST COLLECTOR. VERSION 1 -w/ 6 INLET PORT. Model #DC2000Y Global Rd.

Ductwork Installation And Product Guide For Dust Collection Systems

SPECIFICATIONS FEATURES

3HP MOBILE CYCLONE DUST COLLECTOR MANUAL FILTER CLEANING MANUAL

hp Dust Collector With Vacuum Attachment

Pentz EF5 Installation Guide

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY

7165 Dust Collector Owner s Manual

Operating Instructions

Operator s Manual. 6 Gallon Model No. VQ607SFD FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference

5HP CYCLONE DUST COLLECTOR MANUAL

7140 Dust Collector Owner s Manual

ASSEMBLY AND OPERATING INSTRUCTIONS 3HP DUST EXTRACTOR. FOX Model F50-843

INSTRUCTION MANUAL 4HP WET / DRY VACUUM VC V 60 Hz 7A. Gal

2HP MOBILE CYCLONE DUST COLLECTOR MANUAL

ASSEMBLY AND OPERATING INSTRUCTIONS 1HP DUST EXTRACTOR. FOX Model F50-841

π H-2549 SANITAIRE UPRIGHT VACUUM SAFETY uline.com

Operator s Manual. Floor Vac Model No. VF408 FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference

BLAST-IT-ALL BUMPER BLASTER

OPERATOR S MANUAL FOR YOUR SAFETY. 4 Gallon / Liter Part No. PB408SV

BATTERY POWERED BACKPACK VACUUM

GARAGE VAC OWNERS MANUAL READ BEFORE OPERATING YOUR SYSTEM

DUST COLLECTORS. OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

Super Dust Deputy / Super Dust Deputy XL Super Dust Deputy Deluxe 4 Owner s Manual Made in the USA. .

Owner s Manual CPU-1QD CPU-1 CPU-1T CPU-2 CPU-2T HEAVY DUTY UPRIGHT VACUUMS. Save These Instructions

690 and Power Fishing Systems

User Manual Box Exhaust Fan Series (Belt Drive)

8 lb Lightweight Vacuum Model CK LW 13/1

OWNER S MANUAL CAVS SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER

Wet/Dry Vacuum Kit

READ AND SAVE THESE INSTRUCTIONS

Operator s Manual. 2.5 Gallon Model No. VOM205P FOR YOUR SAFETY. Read and understand this manual before use. Keep this manual for future reference.

ERGO BACKPACK VACUUM OWNER S MANUAL

MC MC MC MC MC833130

DUST COLLECTOR OPERATION AND SAFETY INSTRUCTIONS FM230 CAUTION: READ THE INSTRUCTION MANUAL BEFORE USING THE APPLIANCE

690 Power Fishing System

OWNER S MANUAL CAVN SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

Corn Flame Energy Corn Stove Model 3000

SHOPSMITH DC-330L DUST COLLECTOR OWNER S MANUAL. For more information: For Question or Support: (937)

Dual Suction System Pro-Lite

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

Owner's Manual. Please read this document carefully before installing and/or using your vacuum cleaning system.

Lite Garage Vacuum Instruction Manual

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

MANUAL COVER. To expedite parts ordering or technical questions, please include your Model and Serial Number listed below in all correspondence.

WET & DRY VACUUM CLEANER

GV 8 quart Model BP BATTERY POWERED BACKPACK VACUUM

INSTALLATION AND OPERATING MANUAL

Xaact Spot. Xaact Hot Spot

SSS Speedster 600 (Model SP-600, #56001) SSS Speedster 1000 OPERATION SERVICE PARTS CARE. SSS Speedster 1000 SSS Speedster 600

For cleaning machines, parts & supplies click/visit Electrolux Home Care Products Ltd.

π H-2268 SANITAIRE UPRIGHT VACUUM SAFETY uline.com

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

Specifying a Dust Collector For a School Wood Shop

e Bath Fan with Light User s Guide

Ultra Lightweight Household & Commercial Vacuums

10 GALLON WET/DRY VAC

COBRA -H EXTRACTOR 120V

WARNING USER S MANUAL. Model iq 2000 Series Dust Collector with manual shaker

INSTRUCTION MANUAL Model: SU3022

User s Manual and Operating Instructions

(The chances are you re never going to read me) Owner s Manual HEAVY DUTY SHD-1T.

Canister Vacuum. OWNER S MANUAL Models CV520HB/HR/HY 120V., 60Hz., 10 Amps

MODEL G HP DUST COLLECTOR OWNER'S MANUAL

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

Canister Vacuums S6EVO. Operations and Parts Manual. Models: S6EVO

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

OWNER S MANUAL AVN SERIES RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

UPRIGHT VACUUM 12-INCH CLEANING PATH

Installation Instructions

Operations and Parts Manual

(The chances are you re never going to read me) Owner s Manual. Model S10E.

OPERATOR S MANUAL & PARTS LIST

Pump Out Vacuums Polyethylene & Steel

SINGLE MOTOR UPRIGHT VACUUM CLEANER MODEL C

Operator s Manual Manual Del Usuario

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

The Original. Deluxe Dust Deputy Owner s Manual For Customer Service. Made in the USA

OPERATING INSTRUCTIONS

CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

SAFETY AND INSTALLATION MANUAL MODEL 8100

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Navigator Upright Vacuum NV70 Series

RETRACTOR TOTAL SYSTEM VAC

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

457LAVBP10QT LAVEX HEPA BACKPACK VACUUM CLEANER

Turbo Stick Vac. OWNER S MANUAL Model EP V., 60Hz., 7.5 Amps.

457LAVEXDM15 DUAL MOTOR HEPA UPRIGHT VACUUM CLEANER

Item # Modular Blast CaBinEt instructions

Atrix Back Pack Vacuum

9420* & * Coin Operated Models C* Commercial Models. Product Information. Important Safety Instructions

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

HI Industrial Utility Heater HI Soleus Air International

BLAST-IT-ALL PRESSURE BLAST CABINET

Transcription:

PSI Tempest 14" Impeller Cyclone Dust Collection Systems Owner's Manual TEMP142 / TEMP142CX (2HP) & TEMP143 / TEMP143CC (3HP) TEMP142/143 TEMP143CC TEMP142CX

PSI Woodworking Products Thank you for purchasing one of PSI's growing family of woodworking products. Our Tempest cyclone systems are engineered and manufactured to the highest standards of quality. You will find the Tempest to be a remarkable dust collection machine. Warranty This product is warranted against defects in material and workmanship for a period of five years on the motor and all other components. This warranty applies to the original purchaser of the product and is limited to the repair or replacement of the product or its parts at the discretion of PSI Woodworking Products. Excluded are parts which have been misused, abused, altered, or consumed by normal operation of the machine. Also excluded are direct or consequential damages to persons, properties, or materials. Your invoice serves as proof of purchase and must be referenced to authorize warranty repairs. Call your dealer for proper authorization. Owner is responsible for returning warranty service parts at their expense. Defective parts will be repaired or replaced at the manufacturer's discretion. Safety Do not use this system near flammable or combustible liquids or gases including gasoline or other fuels, cleaners, oil-based paints, natural gas or explosive dusts like coal dust, magnesium, grain dust, or gun powder. Do not vacuum anything that is burning or smoking such as cigarettes or hot ashes. Do not vacuum toxic materials or use near hazardous materials. Do not use outdoors or on wet surfaces. Do not operate with a full waste container. To avoid collapse, use 26 gauge steel or thicker for ductwork. Contents Warranty.....2 Safety.....2 Features...2 Specifications...2 Components......3 Assembling Cyclone...4 Assembling Filters...5 Filter Maintanence...5 Installation and Operation...6 Accessories...7 Install on a stable level surface. Because the Tempest is top-heavy, be certain to secure the motor/blower unit to a wall. If assembled on a stand, make sure the base and supporting structure is stable. Secure the upper portion of the unit with safety wire. Do not use without filter bag or canisters attached. Turn off controls before unplugging. Do not pull cord to unplug, grasp plug and remove from receptacle. Do not operate with the motor/blower off of the cyclone- this could cause severe overheating and/or motor burnout. Do not use with damaged cord, plug, or other parts. Only install to a properly grounded outlet. Do not wear loose clothing in the area of any inlets because high suction could pull and stretch garments into blower If your ductwork consists of only plastic hose or pipe, ground hose or pipe by wrapping bare copper wire around the exterior surface and ground the wire at either end. Keep hands free from spinning impeller. The Tempest is only warranted and guaranteed for the collection of wood dust although it may be quite suitable for other applications. Features Powerful motor blower unit has a proven flawless performance record Able to capture over 99% of all dust and debris before it passes through the motor blower 5-micron filter bag or 1/2- micron filter cartridge for fine filtration Includes wall support brackets Simple operation and easy cleaning of debris from the collection canister With nearly clean filters, system consistently runs at peak performance 14" aluminum impeller provides superior performance "Neutral vane" intake maximizes airflow. Longer cyclone funnel improves separation efficiency Includes convenient heavy-duty on/off switch on power cord Designed to fit under 8 ft. ceiling (with 21" fiber drum). 72" x 24" 5-micron filter bag SPECIFICATIONS Tempest 14" 2HP Tempest 14" 3HP Max CFM Free Air 1900 CFM 2200 CFM VAC, Max Amps (single phase) 220V, 10 amp 220V, 14 amp HP 2 HP 3 HP Max Static Pressure 10.6" 11.4" Impeller Diameter 14" Aluminum 14" Aluminum Sound 75-90 Db 78-93 Db Gauge of Cyclone Body 17 ga 17 ga Weight (motor & cyclone) 146 lbs 165 lbs 2

Components 1) Motor blower unit DC14MB2HP for TEMP142 / TEMP142CX DC14MB3HP for TEMP143 / TEMP 143CC 2) Cyclone assembly consisting of: top cylinder center flange with 9 sets of nuts and bolts bottom cone gasket two screw-mount wall brackets 3) Drum kit consisting of: 2 ea. 7" hose clamps 1 ft. of 7" diameter hose 7" diameter flange 4) Outflow assembly consisting of: 2 each flexible 6" diameter elbows (TEMP142, TEMP143) one 6" hose clamp (TEMP142, TEMP143) 2 each 6" hose clamps (TEMP142CX, TEMP143CC) 4' clear flexible hose (TEMP142CX, TEMP143CC) 5) Filter Packs: TEMPEST Cyclone Manual fig. 1 - Tempest Dimensions 7 1/2" 18" 6" 6" 7" 17 1/2" 94" 22" 26-3/4" Bag Style Cartridge Style Cartridge Style TEMP142/143 (bag filters) TEMP142CX TEMP143CC 1ea. 5 micron bag (BCYC6) 2ea. 26" filter (CYFA) 2ea. 36" filter (CYF36) 2ea. adjustable elbows 1ea. fiber cleanout can 1ea. metal cleanout can (R-90E06) (CYFILCAN3) (CYFILCAN2) 2ea. 6" hose clamp (DBC6) 2ea. 6" hose clamp (DBC6) 2ea. 6" hose clamp (DBC6) 1ea. bell mouth (N-BELL06) 1ea. bell mouth (N-BELL06) 4ft. clear plastic hose 4ft. clear plastic hose (CYH142CC) (CYH142CC) 21" 12" 7" (drum sold separately) fig. 2 - Filter Dimensions 36" 26" 85" 72" 65" 26" 36" 5-micron Filter Bag BCYC6 Used with TEMP142 and TEMP143 24" 1/2-micron Filter Canisters CYFA Used with TEMP142CX 3 13" 13" 1/2-micron Filter Canisters CYF36 Used with TEMP143CC 14" 13"

PSI Woodworking Products Assembly To make the assembly easier, it is suggested that the entire unit be assembled, on the floor, to a sheet of 3/4" plywood and carefully lifted into place. 1) Align the vortex pipe (D) with the screw holes at the top of the upper cyclone body (B) and secure with three M8 x 16 bolts, washers, nuts, and a bead of silicone caulk. Make sure the bolts are first positioned from the top of the upward cyclone body downward. The washers and nuts will be protruding below the three holes of the vortex pipe (D), TIGHTEN. Failure to correctly orient these fasteners may result in damages to the motor blower. 2) Carefully invert the motor blower assembly (A) onto a smooth soft surface (e.g. carpet) and align (B) so that all (8) holes are matched. Adjust the relationship of the inlet and exhaust ports of the cyclone to match your floor plan. Firmly secure A to B with a bead of caulk and 8 pan-head flange bolts (M6 x 12). Carefully, lay the assembly aside at this time. 3) Locate the neutral vane cylinder (C) and slip it into the suction intake of the upper cyclone body (B). The neutral vane cylinder should extend 5" out of the intake port. Secure it with silicon caulk or sheet metal screws (not provided). 4) Locate the adhesive-backed foam strip (G) 64" x 3/8" x 1/16" and carefully attach it to the large flange at the top of the cyclone cone (E). This will assure an airtight seal between the body (B) and the cone (E) sections. Put the cone section in place over the inverted body aligning the 10 holes for the ten M8 x 30 hex head bolts, nuts, and washers. Insert the ten bolts and washers through the bottom of the box flange and secure with the appropriate nuts. (Use the four longer bolts through the holes which will align with the mounting brackets (F).) Do not tighten at this time. The unit is now ready to be fastened to the wall. 5) Determine an appropriate location for your cyclone. Setting the Tempest upright in its final position will require the assistance of another person. The two mounting brackets (F) should be mounted as shown 19-7/8" apart on the centerline of the bolt slots. Take into consideration the height of your ceiling and the height of your barrel and determine the proper height to mount the wall brackets. Depending on the construction of the selected wall, use six best grade 1/4" lag bolts or concrete fasteners. Firmly attach the brackets to the wall and test for strength. 6) Note: Of the 10 bolts holding the body (B) to the cone (E), the four longer ones should be removed at this time. These four bolts, 2 each, located on either side of the unit will be used to connect the unit to its wall brackets. Lift the entire system into position and fasten it to the wall brackets using the four bolts (M8 x 30) taken from the upper flange. Tighten all 10 bolts and nuts. 7) Screw the wall-mounted on/off switch to an appropriate location. Keep in mind small children and your own convenience. Be sure to connect to a 220V power service. 8) Using the 7" waste can flange (H) as a template cut a 7" hole in the lid of your waste can and drill 8 each 3/8" holes for 3/8" hex bolts (not provided). Bolt and seal the flange to the top of the can with a quality silicone sealant (#CYSCAULK). Let this cure for 24 hours before testing. Connect the waste can lid to the bottom cyclone flange with the included 12" x 7" clear flex hose (I) and hose clamps (L). 9) Secure the motor to the wall with the supplied support bracket (K). Carefully remove the two top bolts holding the motor to its support 4 and attach the bracket to the support plate on the motor using these same two bolts. The wall end of the bracket should be mounted to the back wall with the same type of fasteners used for the wall brackets (F). 10) Install filter bag or cartridges as described on page 5. 11) Finally, with the unit operating, inspect all seams and connections for pin-hole leaks. If any appear, they should be filled with a premium silicone caulk and given enough time to fully cure before re-testing. Failure to seal properly will result in excess dust in your final stage filter bag or cartridges. Congratulations, you are ready to use your new PSI Tempest! motor blower assembly neutral vein cylinder extends 5" out of intake upper cyclone body adhesive foam mounting bracket cyclone cone connection hose drum connector flange waste can (sold seperately) fig. 3 - Tempest Components C G J I B E A D H L K motor support bracket long screws vortex pipe F mounting bracket 7" hose clamps

Assembling 5-micron Collection Bags Models TEMP142 and TEMP143 with standard 5-mIcron felt bag (BCYC6) This high filtration bag collects any super fine particles that may pass through the cyclone unit. It has a zipper on the bottom for easy cleaning access. It may hang vertically from the motor blower or positioned anywhere else in the shop, even along the ceiling. Remember, virtually no dust will collect in this bag. It is primarily used to prevent super-fine dust from re-entering the air. Two 6" diameter metal duct elbows connect to the bag from the motor blower. Used on models: TEMP142 and TEMP143 Connecting the 5-Micron bag to the motor blower exhaust port. Fit together two 6-inch adjustable sheet metal elbows (included). Secure the two together with pop rivets, small sheet metal screws, adhesive caulk, or duct tape. Insert corrugated end of elbow into the exhaust port of the motor blower and seal. Now, connect the 72-inch bag to the adjustable elbow with the 6-inch hose clamp provided. Bag Positioning Hang the 5-micron bag vertically, with the zipper on the floor. However, if needed the bag can be suspended horizontally using two hangers (not provided) attached at either end of the bag at the seams. Bag Maintenance Never wash the bag. Water will cause the material to lose its effectiveness. After using the bag for approximately 6 hours, whack the outside of the bag with the equivalent of a wooden yard stick. This will free up most of the fine dust attached to the inside walls. Periodically unzip the bottom and clean out. motor blower TEMPEST Cyclone Manual fig. 4 - Bag Filter Diagram filter bag (2) 6" diameter elbows 6" diameter hose clamp Assembling 1/2-micron Canister Filters Models TEMP142CX and TEMP143CC with 1/2-micron cartridges Refer to the chart below to determine the configuration of your cyclone system. Model Cartridges Hose Cleanout Can #TEMP142CX 2 ea. #CYFA #N-FH063 #CYFILCAN3 (fiber) 26" length x 13" dia. #TEMP143CC 2 ea. #CYF36 #N-FH063 #CYFILCAN2 (steel) 36" length x 14" dia. Assembly of the 1/2-micron Cartridges and Cleanout Can Preparation of Cartridges Apply a large amount of silicone adhesive to the top of the lower cartridge (A). Place the second cartridge on top of the adhesive and firmly press down, making an airtight fit. This adhesive needs a full 24 hours to cure. While curing, apply adhesive around the cartridge neck connector (B). Preparation of Cleanout Cans For CYFILCAN3 (C), cut a 8" hole in the center of the can's lid. Next, use the blast gate to scribe a 4"cutout hole on the side of the can. Cut the hole and use a generous amount of caulk to seal the gate into the hole. Set the cartridge filters on top of the cleanout can. Use a silicone adhesive to seal the bottom of the lower filter to the top of the cleanout can. Cartridge and Cleanout Can Maintenance Keep filters dry at all times. Use compressed air or a shop vacuum to clean the cartridges. Set the compressor to 40 psi and move the air source up and down the outside of the cartridge, aiming towards the center. Take time to clean each pleat of the filter from top to bottom. Very fine dust will fall into the cleanout can and accumulate. Periodically, use your shop vacuum to remove dust from the cleanout can. For best results, insert the suction end of the shop vac into the can via the mounted blast gate or access door and turn it on. Blow the filters clean with the vacuum's exhaust while pulling the dust through the cleanout port on the can. This will prevent fine dust from travelling back through the system. The can should be checked about every six months. fig. 5 - Canister Filter Assembly motor blower connector hose 6" hose clamps neck connector B adhesive upper cartridge A adhesive lower cartridge rubber gasket C cleanout can 5

PSI Woodworking Products Tempest Cyclone Operation and Installation Suggestions 1) Try to maintain the largest possible diameter of ductwork throughout the shop leading up to connections with your machines. The air inlet to the Tempest cyclone is six inches in diameter. Therefore, use 6" ductwork throughout the shop if possible. Because 30ga. galvanized HVAC may collapse under pressure from the vacuum, we suggest using strong (26ga. or heavier) spiral metal pipe as distributed by PSI. 2) Use "Y" or lateral type bleed offs from the main (as opposed to a "T"). This will help to maintain more efficient airflow. The diagram below indicates laterals that feed to 6" extension lines and then to 4" hookup drops for machine connections. 3) Use blast gates at every connection between machinery and ductwork in order to close branches when not in use. 4) Since it is conductive, no grounding is necessary when using galvanized metal ductwork. Check continuity to be sure the entire system is grounded. 5) To maximize airflow, avoid sharp 90 turns and excessive reductions in hose diameter. 6) Poor air flow or excessive dust in the filter bag may be a result of a poorly sealed system. The most common leak is at the drum lid. Check the lid and all other connections at the cyclone to ensure the best performance. fig. 6 - Ductwork Layout Diagram 25 N-BC04 4" SPIRAL DUCTWORK 20 15 10 N-CAP106 7 LAT664 (ROTATED DOWNWARD) 7. MITRE SAW 45E06 5. JOINTER 6. TABLE SAW 5 N-CAP106 4 N-CLAT64 4. PLANER 3. ROUTER TABLE WORK TABLE N-BC06 6" SPIRAL DUCTWORK SEC06 5 1. BAND SAW 6 LAT666 1 LEC06 SEC06 3 N-CLAT64 45E06 N-CLAT66 2. DRILL PRESS LAT664 2 8 LEC06 0 5 10 15 20 25 30 35 SEC06 R 10 1 2 3 4 5 90E06 6 7 8 90E06 LEC06 RED-64 45E04 LEC06 RED-64 5 N-FSW04X 0 5 10 15 20 25 30 35 6

Available Accessories for TEMPEST Cyclones 1. 26ga Snaplock Pipe Snaplock metal pipe is economical, smooth, and practical. It is delivered open and flat snap it together and lock it along the length of the pipe s seam to make your pipe. It is an easy cut to length with shears. Available in 5' lengths only. 2. Heavy Duty Spiral Pipe (24 gauge) The inside of the pipe is very smooth while the continuous outside seam provides superior support and strength. Large ends adapts to small end coupling and fittings. Available in 5' lengths only. 3. Long Ranger Remote Dust Collector Switch - LR220-3 Save yourself the inconvenience of walking over to turn on your cyclone when you find you re in the middle of a critical project. Simply press the transmitter on/off button to easily switch your cyclone on or off. 4. Long Ranger MultiGate Switch System - LRMSET220 Turn on your cyclone when you open your blast gate. Never forget to turn your dust collector on or off. Make it automatic when your cyclone is wired to the MultiGate switch system. 5. Ecogate Automatic Dust Collector and Blast Gate Switch - ECOGATE4 The ECOGATE system opens your blast gate and turns on your cyclone when you turn on your woodworking machine, then shuts the gate and turns off the cyclone when the machine is switched off. For 1HP @ 110V or 1-1/2HP and 2HP @ 220V collectors. 6. Cyclone Muffler - TEMUFF-6 Reduces cyclone sound by 50% (10db) without effecting machine performance. Attaches between cyclone and filter. Requires hose to connect. Length of muffler with flanges is 23-3/4" and has a 6" diameter connection. 7. Dust Level Sensor - BINSENSOR Sounds an alarm when your cyclone's bin is full No more guessing about the dust levels in your cyclone's collection drum. A rotating paddle mounts through the lid of your container and activates the sensor when the paddle is stopped by a high sawdust level. Includes a 110V power cord and a relay connection that can activate an external devise such as a visible light bulb. 8. Dual Drum Kit - CYDDK Double the amount of dust you can collect before you have to empty your drums. Includes: 7" wye and cyclone connector, a 7" connection hose, two flanges, & band clamps. Adds 12" height to cyclone. 9. 26 gal. Fiber Drum - CYDRUM26 A great low profile high capacity container. Lid removes easily with clamp release. 10. Table Saw Dust Collection Guard - TSGUARD This Guard is the ideal solution for table saw safety and dust control. When connected to a dust collection system, the PSI Dust Collection Guard captures the dust thrown up by your table saw blade. The Guard can be used on any table saw with an extension table. It is very easy to install and easily swings out of the way. A unique counter-balance allows for fast and easy positioning. 11. Dust Grabber Downdraft Table - DGTABLE2 The Dust-Grabber sanding table captures the dust before it enters the air you breathe. Non-slip perforated, non-marring surface. Strong, laminated hard board construction. and easy positioning. 7 TEMPEST Cyclone Manual Accessories 1 2 3 4 5 6 7 8 9 10 11

PSI Woodworking Products Notes 2005 PSI Woodworking 9900 Global Road, Philadelphia, PA 19115 V2-0305 8