BUILDING ASSESSMENT REPORT ELECTRICAL SERVICES FOR 75 FOX STREET BUILDING

Similar documents
GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

ELECTRIC SERVICE EVALUATIONS ELECTRICAL / BOILER REPLACEMENTS. Clarkstown Central School District. June Arch Proj. #

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

SECTION 1.02 DETAILED SCOPE OF WORK

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

Palak Parikh, Lalit Lopez GE Digital Energy. Acknowledgment: Scottish and Southern Energy(SSE)

Technical Report 2: Electrical Systems Criteria and Existing Conditions

Corbin Building. Technical Assignment 2. Matthew Trethaway Lighting/ Electrical AE 481W 10/26/2011 Advisor: Ted Dannerth

Telecity. Table of Contents. Page. Section 3.2

Power Plants with Webel Solar Modules

ELECTRICAL AND COMMUNICATION INSTALLATION DESIGN IN AN OFFICE COMPLEX

COMPANY PROFILE Electrical & Instrumentation Contractor

Monitoring of Electrical Equipment Failure Indicators and Alarming

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

Lindsay Frederick. Lighting + Electrical. Ron Dodson Faculty Advisor. Native American Cultural Center Arizona. Technical Report 2

ELECTRICAL SAFETY INSPECTION REPORT

INITIAL ELECTRICAL SAFETY ASSESSMENT - EXPANSION

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

DOMESTIC INSTALLATIONS COMMERCIAL INSTALLATIONS LIGHTING SOLAR PV REPAIRS LANDLORDS SWITCH ON TO SWH ELECTRICAL SOLUTIONS

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

GARCIA GALUSKA DESOUSA Consulting Engineers

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

2009 ELECTRICAL CODE REQUIREMENTS

GeyserWise MAX. Thermostat instruction manual. SANS 181 compliant. All in one hot water management

GeyserWise MAX. Instruction manual. All in one hot water management

MODULAR TRACTION SUBSTATIONS CITY ELECTRIC TRANSPORT

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

NATIONAL TRAINING BOARD (ELECTRICIAN) REGULATIONS 2008 BR 54/2008 NATIONAL OCCUPATIONAL CERTIFICATION ACT :38

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

AQ 100 Series. Arc Flash Protection System

Project Briefing Document. Section 3 Electrical Services design guide and specifications

Section 8 Electrical.

Electrical Design Guidelines Table of Contents

How to light a small storage space rabdesign.ca 1

Comprehensive Inspection Agency (CIA) RESIDENTIAL & COMMERCIAL FEE SCHEDULE

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

Photovoltaic (Solar) Array Installation Guide

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL

2 X 1996 Wartsila 18V mw Each 50hz HFO Generator Sets

Table-1: Clarifications and modification in tender specifications based on Pre-bid meeting discussion

Currently, all electrical upgrades would be voluntary, but there are situations in which upgrades would be required.

A student investigated how much energy from the Sun was incident on the Earth s surface at her location.

User Information Sheet 008 : 2010

Home Energy Management (Device Control): Immersion Heater Controller Use Cases, Application Note

ELECTRICAL SAFETY INSPECTION REPORT ANLIMA TEXTILE LTD, DHAKA, BANGLADESH

PART 1. Executive Summary. The Frederick College of Cardiology

ADVANCE ELECTRICAL MEP CONTRACTING TRADING SERVICES

Installation and Maintenance Manual for Dimako NERM Panels REV 4. NERM Reference Manual NERM Panels 1 of 7

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

Work involving High Voltage (HV) Systems and Maintenance of Plant.

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

Chang Liu Lighting + Electrical M.A.E./B.A.E. Integrated Degree. Technical Assignment 2 October 12, 2012 Faculty Consultants: Ron Dodson

Ground Fault Protection Improvement Study

ENTSO-E response to GB compliance understanding

PROFILE. industrial services rental trading

Comprehensive Inspection. (CIA) RESDENTAL & COMMERCIAL

Element D Services Electrical

Development of standards for MV Switchgear for Arc Flash protection. ABB Group May 20, 2013 Slide 1

Introduction Consultant shall incorporate the material in the DSS into the project specifications.

COSINE DEVELOPMENTS Reg. No. IT 1637/97

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

TIME KNITWEAR (PVT) LTD.

Annexure - D. Station Interface Matrix Power Supply, S&T, AFC,Lift & Escallators,Rolling stock and Track work. Station Civil and E & M Contractor

KTDC HOTELS & RESORTS LIMITED MASCOT SQUARE, TRIVANDRUM - 33

PANELBOARDS & BUILDING DISTRIBUTION

NEW ENERGY IN THE BATTERY INFRASTRUCTURE

FIRE SAFETY INSPECTION REPORT

ABB Medium Voltage Days MEA 2016 Proactive safety ABB medium-voltage switchgear

TONY ESPOSITO LIGHTING/ELECTRICAL TECHNICAL REPORT II SEPTEMBER 15, 2011 HUNTER S POINT SOUTH INTERMEDIATE SCHOOL AND HIGH SCHOOL QUEENS, NY

ESTIMATE SET-UP PACKAGE BID SCHEDULE ENTRY AND MAINTENANCE

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

ILLUMINATOR EM. CENTRAL LIGHTING INVERTER 1000 VA/W through 2800 VA/W 98% Efficiency!

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

BALTIMORE CITY RENTAL LICENSE INSPECTION FORM RENTAL LICENSING INSPECTOR GUIDANCE

Teesside University upgrades its emergency lighting system with Hochiki Europe

Consumer unit replacement in domestic and similar premises

NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies

ELECTRICAL POWER SYSTEMS

Substation Signage. Document Number: 1-11-FR-12

Photovoltaic Specialists: Job Task Analysis

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

Guided Learning Hours (GLH) 8 Invigilated Assessment Hours (IA) 2 Total Qualification Time (TQT) 10

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

V4 15JUNE2016 (COPYRIGHT: DEPARTMENT OF INDUSTRY)

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

ELECTRICAL DESIGN BRIEF

Riverdale NetZero Project Summary of Costs and Expected Performance

Transcription:

GAUTENG DEPARTMENT OF INFRASTRUCTURE DEVELOPMENT BUILDING ASSESSMENT REPORT ELECTRICAL SERVICES FOR 75 FOX STREET BUILDING September 2014

Contents 1. INTRODUCTION... 3 1.1. Design Criteria and Specification... 3 1.2. Scope of the Services Scheme Report... 3 2. PROJECT SUMMARY... 4 2.1. Project Description... 4 3. ELECTRICAL SYSTEMS... 5 3.1. MV Network... 5 3.1.1. Switchgear and Cabling... 5 3.1.2. Transformers... 6 3.2. Main Low Voltage Panel... 7 3.3. Emergency Power... 8 3.3.1. Stand-by Generator... 8 3.3.2. Change-over Panel... 9 3.3.3. Un-interrupted Power Supply... 10 3.4. LV Distribution Boards/Floor DBs... 12 3.5. Lighting Small Power... 13 3.6. Solar System... 15 3.7. Building Earthing Bonding and Lightning Protection... 16 3.8. Power Factor Correction and Harmonic Filter... 17 4. RECOMMENDATIONS... 19 4.1. Imbuba House/75 Fox... 19 4.2. Energy Efficiency considerations... 19 2

1. INTRODUCTION Imbuba House is located on 75 Fox Street, Johannesburg, Gauteng (see Locality Map): Figure 1 - Locality Map The project brief, as issued by Gauteng Funding Agency (GFA), was to conduct an initial assessment of the building electrical infrastructural condition and to provide recommendations regarding the repairs and renovations of the buildings electrical infrastructure of Imbuba House/75Fox Street. 1.1. Design Criteria and Specification This project will be implemented in compliance with all the requirements of the National Building Regulations and SANS10400. 1.2. Scope of the Services Scheme Report This report deals with the condition of existing electrical services and recommendations on electrical services to be implemented based on the existing systems and proposed architectural changes to the building. Remedial work to be carried on the services and equipment affected. It also deals with proposed new works as per the new layouts from the Architects. 3

2. PROJECT SUMMARY 2.1. Project Description The building is currently occupied on all the floors. The electrical installation is still intact, and it s in a good state except for the plant room where there are signs pointing out that there was theft copper earthing cables which now puts the entire electrical installation under danger because it unknown on where exactly this took place; However it was seen that a replacement of copper with anti-theft earthing cable took place. The due diligence involved inspecting the following: MV Network Transformers Main LV Panels Emergency Power and UPS Low Voltage DBs/Floor DBS Lighting and Small power Solar system installed on the roof. Building bonding and Lightning protection Power Factor Correction 4

3. ELECTRICAL SYSTEMS 3.1. MV Network 3.1.1. Switchgear and Cabling The switchgear and its cabling are in the basement in the transformer room. The switchgears are intact but quiet old. Visually they are well maintained in a good condition. The transformer room is well ventilated and clean. Figure 2 11KV Switchgear Figure 3 11KV Switchgear Figure 4 11KV Metering Cubicle Figure 5 MV Network 5

Figure 6 MV Network We recommend that the MV Network (Switchgears and Metering Unit) be replaced with modern equipment because after so many years (above 25years) of existence, the protection ability of the switchgears cannot be relied up on in next coming years. 3.1.2. Transformers There are four 1000KVA transformers in the basement transformer room. All of the transformers are intact and visually they are well maintained in a good condition. The transformer room is well ventilated and clean. Figure 7 11\0.4KV Transformer 1 - Figure 8 11\0.4KV Transformer 2 - Operational Operational 6

Figure 9 Transformer 3&4 Operational Figure 10 Cooling Fans Figure 11 Transformer Feeder Panel (TRF 3&4) We recommend that the transformers undergo maintenance tests; otherwise they are in a good condition. 3.2. Main Low Voltage Panel The Main low voltage panel is in the basement in the LT room. The room was neat and clean. The distribution boards for the main LV panel and its components are very old, however they are intact, well maintained and are in a good working condition. 7

Figure 12 Main LT Room and Panels Figure 13 Main Supply Transformer 1 Figure 14 Main Supply Transformer 2 We recommend that the Main LT equipment be upgraded to modern equipment. 3.3. Emergency Power 3.3.1. Stand-by Generator The building has 2 Generator rooms in the basement, Generator room 1 has 2 of 750kVA generator sets and Generator room 2 has 1 of 1000kVA generator set. All of these generator sets are in a good working condition and do not need replacement or upgrade. 8

Figure 15 Two Generator Sets (750kVA) in Generator Room1 Figure 16 Generator Set (100kVA) in Generator Room2 Figure 17 Generator-A Log Book Figure 18 Generator-B Log Book 3.3.2. Change-over Panel The generator change-over panels are well maintained, in a good condition and they are working. 9

Figure 19 C/O Panel Generator-A Figure 20 C/O Panel Generator-B Figure 21 Generator Controller A Figure 22 Generator Controller-B Figure 23 C/O Panel and Generator DB (100kVA Gen-Set) We recommend that the Generator and Change-Over panels be tested and commissioned. 3.3.3. Un-interrupted Power Supply The UPS System is in the UPS room, it is intact, the condition of the system is good and compliant except for the clumsy cables and earthing cables which are not labelled. 10

Figure 24 UPS Units 1&2 (300kVA) Figure 25 UPS Units 1&2 (630kVA) Figure 26 UPS Return 1&2 (630kVA) Figure 27 UPS Outgoing Supplies to Various DB s Figure 28 UPS Battery Store/Room Figure 29 UPS Room Cable Reticulation (Clumsy) 11

Figure 30 UPS Room Earth Cables (no labels) We recommend that all the cables be contained together, labeled for compliance and the UPS be tested and commissioned. 3.4. LV Distribution Boards/Floor DBs The DBs on most floors are in good working condition; however there are few things to be sorted such as; Containment of wires in the DBs Upgrade the some of the DBs and Panels components to modern technology Remove/clean the DB spaces Label all the cables Figure 31 DB-E14 in the Lifts control room Figure 32 Lift DB 12

Figure 33 Installed Floor DB-XEL14 Figure 34 Installed Bus-bar riser Figure 35 Typical Floor DBs Figure 36 Bus-bar riser (old fuser switch) We recommend that the above mentioned issues be sorted 3.5. Lighting Small Power Most of the building floors have under floor plug points with normal and emergency power. The condition of the plugs is good. The building lighting is good in areas such as the basements, plant rooms, etc, however in the floors there are issues with the lighting and below they are stated; Light fittings are old and some are not working Insufficient light levels in the office areas due the old lights, results to lux levels not meeting minimum office requirements Very Bad connection/ wiring for the lights( connection non-compliant) On fire escapes, it s dark, emergency lights (bulkheads) to be upgraded. 13

Figure 37 Dark office space with some Lights not working Figure 38 Office space (insufficient light levels) Figure 39 Bad and non-compliant connection Figure 40 Office space (insufficient light levels) Figure 41 Parameter lighting 3302/E&E/H/001 14

We recommend that the old light fittings be replaced with new energy efficient lights to achieve minimum requirements lux levels and parameter lighting be sorted out. 3.6. Solar System 20 solar panels were installed on the roof. Total power calculated is about 2.2kw. It could not be ascertained what the system supports since there is no drawing or information on site. The system consists of panels and inverter but no batteries. We recommend that information be made available and the system be maintained in line with energy efficiency. Figure 42 Installed solar panels (east) Figure 43 Installed solar panels (west) 15

Figure 44 Solar PV Array Controller (West) Figure 45 Solar PV Array Controller (East) 3.7. Building Earthing Bonding and Lightning Protection It was seen that the building bonding and lightning protection is not intact and compliant, which in turn pose danger to the building and people in it when there is lightning. Figure 46 Building Earth Figure 47 Clumsy Earth Cables 16

Figure 48 Loose Lightning rod and conductor Figure 49 Lightning rod with no conductor Figure 50 Lightning rod wit h no conductor Figure 51 Lightning Conductor with Intact We recommend that the building bonding and lightning protection should undergo repairs to achieve compliance. 3.8. Power Factor Correction and Harmonic Filter The building has Power Factor Correction Equipment both for normal power and emergency power and Harmonic Filter Equipment in the LT Room. The PFC equipment and Harmonic are intact and in a good working condition. We recommend that these equipments be tested and commissioned, otherwise they seem good. 17

Figure 52 PFC Equipment (normal power) Figure 53 PFC Equipment (emergency power) Figure 54 PFC Equipment (normal power) Figure 55 Harmonic Filter We recommend that these equipments be tested and commissioned, otherwise they seem good. 18

4. RECOMMENDATIONS The remedial work required to meet the minimum national standard and reinstate the building s electrical system and infrastructure is recommended above on each equipment and a high level budgetary cost for the remedial work is presented below. 4.1. Imbuba House/75 Fox All the electrical works to be designed and re-done in accordance to SANS 10142-1 and SANS 10400. Below is a brief summary of the remedial work to be done. 1. Install 4 new 11KV Switchgears and Ring Main Unit 2. Main Low Voltage Board and all its associated equipment be upgraded 3. It is recommended that further examination and testing of transformers is conducted 4. Generator, Change-Over panels and UPS Systems be tested and commissioned 5. Repairing of existing floor DBs 6. Rewire the building (small power and lighting) according to current building and floor layouts 7. Building Bonding and Lighting Protection be repaired 8. We recommend that the PFC and Harmonic Filter equipments be tested and commissioned 4.2. Energy Efficiency considerations The following initiatives will be implemented. 1. Occupancy sensors in storerooms, kitchens, offices and open plan areas. 2. Introducing daylight saving in public areas and offices. 3. Installation of a BMS to control and monitor Air conditioning and lighting. 4. Installation of smart meters on all floors and this will be linked to the BMS. 5. Installation of geyser control systems where water heating is installed. 6. Use of T5 Lamps and LEDs. 7. Use of DALI controlled lights for controlling light fittings. 8. Maintaining the solar system installed and use it on energy lighting 19