Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

C7 Series Split System Uncased Indoor Coils

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

INSTALLATION INSTRUCTIONS TXV Coils EBD, EBA

INSTALLATION INSTRUCTIONS TXV Coils EBU, EBA

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

User s Information and Installation Instructions

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

EVAPORATOR COILS Installation Manual CCG, VCG, MCG M Series Coils

Installation Instructions

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

NOT DESTROY. PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

GAM SERIES INSTALLATION & OPERATING INSTRUCTIONS MULTI-POSITION AIR HANDLER (ELECTRIC HEAT)

INSTALLATION INSTRUCTIONS TXV Coils EDM, EDD, EDA

Installation Instructions

GAW SERIES INSTALLATION & OPERATING INSTRUCTIONS VERTICAL WALL MOUNT AIR HANDLER (ELECTRIC HEAT)

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

USER'S MANUAL/INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION & OPERATING INSTRUCTIONS AAW SERIES VERTICAL WALL MOUNT AIR HANDLER (ELECTRIC HEAT)

Installation Instructions

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Installation Instructions

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION MANUAL WARNING WARNING FULL-CASED UPFLOW/COUNTERFLOW FOR COOLING/HEAT PUMPS FULL-CASED MULTI-POSITION FOR COOLING/HEAT PUMPS MODELS: CF

Installation Instructions

INSTALLATION INSTRUCTIONS

1. Air Handier Specifications Unit Dimensions Installation Requirements... 5 Minimum Ampacity and Maximum Overcurrent Protection...

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES

Evaporator Coil. Installation Instructions GENERAL

INSTALLATION INSTRUCTIONS

PL Series Premier Indoor Plenum Coils

UPFLOW/DOWNFLOW COILS

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY UIM-C-0214

INSTALLATION & OPERATING INSTRUCTIONS AAC & AEC SERIES CEILING MOUNT AIR HANDLER (ELECTRIC HEAT)

CBX32MV (HFC-410A) SERIES UNITS

Evaporator Coil. Installation Instructions GENERAL

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY

ASSEMBLY and INSTALLATION INSTRUCTIONS. Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key

User s Information/Installation Instructions

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Installation Instructions

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

AVS Series Air Handlers Installation Manual for CLASSIC SERIES SYSTEMS Models SC, SD, and SDH

INSTALLATION GUIDE. AAM and AEM Series - Multi-Position Air Handler (Electric Heat) ! WARNING ! CAUTION. 1. Safety Instruction. 2.

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

TECHNICAL SPECIFICATIONS

Installation Instruction

R-410A. Installer s Guide WARNING: 18-GE04D2-5

EL SERIES INSTALLATION INSTRUCTIONS

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP MODELS: TABLE OF CONTENTS LIST OF FIGURES

USER S MANUAL AND INSTALLATION INSTRUCTIONS IMPORTANT

INSTALLATION GUIDE. AEC & AAC Series - Ceiling Mount Air Handler (Electric Heat) 1. Safety Instruction. 2. Introduction !

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions Replacement R-22 A-Coil Model RCTA- 8060

INSTALLATION INSTRUCTIONS FOR RCQD COILS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

RCTA Horizontal Evaporator Coil Installation Instructions

Installer s Guide Convertible Air Handlers 1-1/2 5 Ton

INSTALLATION INSTRUCTIONS

Installation Instructions

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG7T (C and L Series)

G6RC Series TECHNICAL SPECIFICATIONS

GBW SERIES INSTALLATION & OPERATING INSTRUCTIONS VERTICAL WALL MOUNT AIR HANDLER (HYDRONIC HEAT)

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE. GBM Series - Multi-Position Air Handler (Hydronic Heat) 1. Safety Instruction

Upflow/Downflow A-Coil Specifications

AVS Air Handlers Installation Manual for Classic SC, SD, and SDH

INSTALLER S GUIDE WARNING: TWE-IN-2A 18-GE02D1-3. Convertible 1 ½ - 5 Ton Air Handlers WARNING HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

Fig. 1--Typical Coil Installation

NOT DESTROY. PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

INSTALLATION GUIDE. GBT/GBS Series - Cased/Uncased Ceiling Mount Hydronic Heat Dx Cool Air Handler ! WARNING. 1. Safety Instruction

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

R-410A. NJ-10 thru -20, 4-Pipe Ton, 60 Hertz TABLE OF CONTENTS LIST OF TABLES LIST OF FIGURES

User s Information and Installation Instructions

GFM SERIES INSTALLATION & OPERATING INSTRUCTIONS HIGH EFFICIENCY X13 MULTI-POSITION AIR HANDLER (HYDRONIC HEAT)

VERTICAL MOUNT AIR HANDLERS

INSTALLATION GUIDE. AFM Series - Multi-Position Air Handler (Hydronic Heat) 1. Safety Instruction. 2. Introduction !

INSTALLATION GUIDE. GFT/GFS Series - Cased/Uncased Ceiling Mount Hydronic Heat Dx Cool Air Handler ! WARNING. 1. Safety Instruction. 2.

Transcription:

Split System Indoor Coils Installation Instructions CAUTION: Read the Installation Instructions supplied with furnace/air handler and observe all safety requirements outlined in instructions and/or furnace/air handler markings before proceeding with installation of the coil These instructions are primarily intended to assist qualified individuals experienced in the proper installation of this appliance. Some local and national codes require licensed installation/service personnel for this type of equipment. Read all instructions carefully before starting the installation.

Table of Contents 1. General Information... 3 2. Coil Specifications... 4 3. Coil Installation... 5 Upflow Furnace Downfl ow Furnace Horizontal Furnace Horizontal Ready Coils for Horizontal Left Installation Horizontal Ready Coils for Horizontal Right Installation 4. Verify Pressurization... 6 5. Refrigerant Line Connections... 6 6. Completing the Installation... 7 Condensate Drain Air Filters Close-off Plates and Panels Refrigerant Charging 7. Maintenance and Service... 8 2

1. GENERAL INFORMATION Standard cased coils are designed for upflow/ downflow applications or horizontal applications when used in conjunction with our horizontal drain pan kit (See page 5). Accessory kits are not required for factory ready horizontal coils. Coils are equipped with braze type refrigerant connections for easy installation. Read the installation manual supplied with the outdoor unit for refrigerant line connection procedure, required line sizes, and other information pertaining to the system installation. 1. Make certain that the air delivery of the furnace/air handler is adequate to handle the static pressure drop of the coil, fi lter, and duct work. 2. Check the orifi ce size of the coil s expansion device and confi rm that it is suitable for application with the intended outdoor unit. NOTE: Some coils employ a thermostatic expansion valve (TXV) as the metering device (See page 4). 3. Where precise forming of the refrigerant lines is required, a copper tubing bender designed for the size lines used is recommended. Avoid sharp bends and contact of the refrigerant lines with metal surfaces. 4. Refrigerant lines should be wrapped with pressure sensitive neoprene or other suitable material where they pass through the raw edges of holes. 5. Coil must be level for proper condensate drainage. NOTE: Optional cooling/heating equipment must be properly sized and installed in accordance with the furnace manufacturer s specifications and approved recommendations. Heating only furnace air circulators may have to be replaced with multi-speed Heating/Cooling blowers to upgrade the air delivery (CFM) when an add-on coil is installed. Refer to Coil Specifications for recommended CFM and allow for pressure drop across the coil and filters. 19 3 /4" A 3/4" H 13 3 /8" 15 5 /8 " B 16 5 /8" 20 3 /4" W Figure 1. 3

2. COIL SPECIFICATIONS Coil Model (1) 024C-A 025C-A 030C-A 024C-B 025C-B Nominal Capacity BTUH (2) 24,000 24,000 30,000 24,000 24,000 30,000 36,000 36,000 42,000 48,000 48,000 48,000 60,000 Nominal Airflow CFM 800 800 1000 800 800 1000 1200 1200 1400 1600 1600 1600 2000 Width (in.) W 14 1/4 14 1/4 14 1/4 19 3/4 19 3/4 19 3/4 19 3/4 19 3/4 19 3/4 19 3/4 22 1/2 22 1/2 22 1/2 Height (in.) H (std/horz) 20/26 20/26 20/26 20/26 20/26 20/26 20/26 26/26 26/26 26/26 26/26 29/29 29/29 Top (in.) A 12 7/8 12 7/8 12 7/8 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 21 1/8 21 1/8 21 1/8 Connections Liquid Li Line 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Suction Line 3/4 3/4 3/4 3/4 3/4 3/4 3/4 7/8 7/8 7/8 7/8 7/8 7/8 Installed Orifice Size (in.) (3) 0.050 0.060 0.065 0.050 0.060 0.065 0.075 0.075 0.078 0.089 0.089 0.089 0.099 Horizontal Drain Kit (7) 919318 919318 919318 919318 919318 919318 919318 919319 919319 919319 919319 919320 919320 Coil Case Adapter (4) - - - 913963 913963 913963 913963 913963 913963 913963 913964 913964 913964 Extra Orifice (in.) N/A 0.053 for 1.5-ton condenser N/A N/A 030C-B 036C-B 037C-B 042C-B 048C-B 048C-C 049C-C 060C-C 0.053 for 1.5-ton condenser N/A N/A N/A N/A N/A N/A N/A N/A Coil Model (1) T/X24C-A T25C-A T/X30C-A T/X24C-B T25C-B Nominal Capacity BTUH (2) 24,000 24,000 30,000 24,000 24,000 30,000 36,000 36,000 42,000 48,000 48,000 48,000 60,000 Nominal Airflow CFM 800 800 1000 800 800 1000 1200 1200 1400 1600 1600 1600 2000 Width (in.) W 14 1/4 14 1/4 14 1/4 19 3/4 19 3/4 19 3/4 19 3/4 19 3/4 19 3/4 19 3/4 22 1/2 22 1/2 22 1/2 Height (in.) H (std/horz) 20/26 20/26 20/26 20/26 20/26 20/26 20/26 26/26 26/26 26/26 26/26 29/29 29/29 Top (in.) A 12 7/8 12 7/8 12 7/8 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 18 3/8 21 1/8 21 1/8 21 1/8 Connections Liquid Line 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Suction Line 3/4 3/4 3/4 3/4 3/4 3/4 3/4 7/8 7/8 7/8 7/8 7/8 7/8 Metering Device TXV TXV TXV TXV TXV TXV TXV TXV TXV TXV TXV TXV TXV Horizontal Drain Kit (7) 919318 919318 919318 919318 919318 919318 919318 919319 919319 919319 919319 919320 919320 Coil Case Adapter (4) - - - 913963 913963 913963 913963 913963 913963 913963 913964 913964 913964 T/X30C-B T/X36C-B T37C-B T/X42C-B T/X48C-B T/X48C-C T/X49C-C T/X60C-C Coil Model (1) (5) C4BA X24C-B C4BH X24C-B C4BA X36C-B C4BH X36C-B C4BA X48C-C C4BH X48C-C C4BA X60C-C C4BH X60C-C Nominal Capacity BTUH (2) 24,000 24,000 36,000 36,000 48,000 48,000 60,000 60,000 Nominal Airflow CFM 800 800 1200 1200 1600 1600 2000 2000 Width (in.) W 19 3/4 19 3/4 19 3/4 19 3/4 22 1/2 22 1/2 22 1/2 22 1/2 Height (in.) H 20 26 26 26 29 29 29 29 Top (in.) A 18 3/8 18 3/8 18 3/8 18 3/8 21 1/8 21 1/8 21 1/8 21 1/8 Connections Liquid Line 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Suction Line 3/4 3/4 7/8 7/8 7/8 7/8 7/8 7/8 Metering Device TXV TXV TXV TXV TXV TXV TXV TXV Horizontal Drain Kit (7) 919318-919319 - 919320-919320 - (1) Refer to sales specifi cation sheets for Listed/Certifi ed combinations of equipment and required accessories. (2) Refer to the current ARI Directory for certified ratings of split systems. (3) Orifice size is for 13 SEER R-22 systems. Additional orifices may be supplied with the condenser. (4) Allows application of larger coil cases to smaller furnace cabinet. (5) X in the model description designates factory installed TXV for R-410A refrigerant. (6) T in the model description designates factory installed TXV for R-22 refrigerant. (7) Not required for "H" horizontal ready coils. 4

3. COIL INSTALLATION WARNING: Electric furnaces may be connected to more than one supply circuit. Upflow Furnace 1. Disconnect all electrical power to the furnace. 2. If needed, use one of the coil case adapter kits to match the coil to the furnace air discharge opening. Refer to the Coil Specifications Section for proper kit numbers. 3. Install the coil and level it as needed to ensure proper condensate drainage. (See Figure 2) 4. Seal the enclosure as required to minimize air leakage. 5. Connect the refrigerant lines as outlined in the Refrigerant Lines section. Downflow These coils may be installed in downflow applications. Installation of the coils in these applications only require that the furnace and coil cabinets are securely mounted together before setting in place. Fossil fuel applications require coil to be placed in the supply air stream only. Horizontal Standard coils may also be installed in horizontal applications. Installation of the standard coils in these applications only require that the furnace and coil cabinets are securely mounted together and that a Figure 2. Upflow Furnace Application horizontal drain pan kit be installed. Refer to the Specifications Section for proper kit numbers. To Configure Horizontal Ready Coils for Horizontal LEFT Installations: 1) Remove the coil access door. 2) IMPORTANT: Remove the plug from one of the threaded holes in the horizontal drain pan. Completely remove the webbing located in the threaded holes of the horizontal drain pan. If webbing is not removed, the drain will not function properly and ceiling damage may occur. 3) Insert a plug (from the horizontal drain pan) into the open and unused drain hole in the drain pan at the bottom of the unit to block bypass air. 4) Remove the corresponding drain line knockout from the coil access door to allow access to the horizontal drain. 5) Replace the door. NOTE: Install drainpan extension (supplied) on the following models: C5BH-*60 C4BH-X36 C5BH-*49 C4BH-X48 C4BH-X60 To Configure Horizontal Ready Coils for Horizontal RIGHT Installations: 1) Remove the coil access door. Unscrew the line-set tube close-off plate from the front left cabinet rail. 2) Slide the coil and drain pan assembly out of the unit. 3) IMPORTANT: Remove the plug from one of the threaded holes in the horizontal drain pan. Completely remove the webbing located in the threaded holes of the drain pan. If webbing is not removed, the drain will not function properly and ceiling damage may occur. 4) Remove the sheet metal hairpin covers (if supplied) from the back of the coil and discard. 5) Place the horizontal drain pan on the opposite side of the coil. On units with 2 sets of knockouts, remove the other set of knockouts in the coil spacing plates and insert support rod. 6) Insert a plug (from the horizontal drain pan) into the open and unused drain hole in the drain pan at the bottom of the unit to block bypass air. 7) Slide the coil and the horizontal drain pan assembly back into the unit. Reattach the tube close off plate. 5

8) Remove the corresponding drain line knockout from the coil access door to allow access to the horizontal drain. 9) Replace the door. NOTE: Install drainpan extension (supplied) on the following models: C5BH-*60 C4BH-X36 C5BH-*49 C4BH-X48 C4BH-X60 Note: All condensate pans have primary and secondary drain connections to meet FHA requirements. If the application is located in or above a living space where damage may result from condensate overflow, a separate 3/4 inch drain must be provided from the secondary drain connection and a secondary drain pan must be installed under the entire unit. Run secondary drain lines to a place where they are noticeable if used. 4. VERIFY PRESSURIZATION WARNING: This coil is pressurized with Nitrogen. Avoid direct face exposure or contact with valve when gas is escaping. Always ensure adequate ventilation is present during the depressurization process. Any uncertainties should be addressed before proceeding. VERIFY PRESSURIZATION: NITROGEN HEALTH FLAMMABILITY - Test by depressing Schrader valve and listen for escaping gas - If no pressure is found, test coil for leak - If no leak is found, install coil - If leak is found, clearly mark leak location and return coil to your distributor for processing 1 0 0 REACTIVITY 0 Minimal Hazard 1 Slight Hazard 5. REFRIGERANT LINE CONNECTIONS WARNING: NITROGEN HEALTH FLAMMABILITY REACTIVITY 0 Minimal Hazard 1 Slight Hazard This coil is pressurized with Nitrogen. Avoid direct face exposure or contact with valve when gas is escaping. Always ensure adequate ventilation is present during the depressurization process. Any uncertainties should be addressed before proceeding. NOTE: For coils with factory installed TXV valve proceed to step #8. NOTE: Before proceeding with the connection of the refrigerant lines, confirm that the orifice size meets the requirements outlined in the outdoor unit installation manual. Factory installed orifice sizes are listed in the Specifi cations section. If the restrictor orifice must be replaced, follow the steps below: 1. Remove the valve cap from the end of the liquid line. Relieve all pressure from the coil by depressing the valve. Remove the valve core. Properly dispose of all removed parts. 2. Loosen the orifice/distributor body halves by applying two wrenches and squeezing them together, as shown in Figure 3, to turn the assembly nut counter-clockwise. 3. Continue to unscrew the assembly nut to separate it from the distributor body portion. 4. Insert a light-gauge wire hook between the distributor body and the orifice to lift the orifice out of the body. (See Figure 4) Remove the orifice being careful not to scratch either part. 5. Check the actual size of the new orifice (the size is stamped on the side of the orifice). Do not use pin gauges to measure the orifice diameter. 1 0 0 6

6. Insert the new orifi ce in the distributor body rounded end down as shown in Figure 5. 7. After installing the orifi ce in the distributor body, realign the assembly nut to the distributor body. Mark a line along both bodies after hand tightening and then tighten an additional 1/4 turn. Caution: Do not overtighten! The misalignment of the two lines will show how much the nut is tightened. If a torque wrench is used, tighten to 10-12 ft. lbs. or 14-16 Nm. Line Connections: 8. Making note of orientation, remove the hole grommets and tube close-off insulation from around the coil and refrigerant line set. 9. Remove the valve cap from the end of the liquid line. Relieve all pressure from the coil by depressing the valve. Remove the valve core. Note: On models which use a TXV, it is recommended to wrap a wet rag around the suction line between the sensing bulb and the line set braze joint before applying any heat. 10. Unbraze and remove the cap on the suction line. Unbraze and remove the valve core holder on the liquid line. 11. Cut the line set tubing to the proper length. Be sure that the tubing has been sized in accordance with the outdoor unit specifi cations. 12. Inspect both refrigerant lines. The ends of the lines must be round, clean, and free of any burrs. 13. Place grommets in proper orientation onto line set with suffi cient distance to braze joint. 14. Insert the line set tubes into the coil tube stubs until they bottom out. 15. Braze the individual connections with dry nitrogen fl owing through the joints to eliminate internal oxidation and scaling. NOTE: On models which use a TXV, it is recommended to wrap a wet rag around the suction line between the sensing bulb and the line set braze joint before applying any heat. 16. Check the assembly for leaks. 17. On horizontal applications of models with TXV valve, re-position the sensing bulb on the suction line so it is in the 4 o'clock or 8 o'clock position on the suction tube. 18. Properly dispose of all removed parts. 6. COMPLETING THE INSTALLATION Condensate Drain: CAUTION: The indoor coil must be checked to ensure a level installation. Failure to do so may result in improper condensate disposal, causing structural damage, premature equipment failure, or possible personal injury. 1. The coil condensate pan is furnished with 3/4" NPSC drain connections. Use a PVC or similar material fitting to attach the drain line to the pan. The fitting should be hand tightened only. Overtightening may crack Figure 4. Removal of Orifice Figure 3. Wrenches on Distributor Body and Assembly Nut Figure 5. Restrictor Insertion in Distributor Body 7

the drain pan and cause a condensate leak. 2. Connect the drain line and run to a suitable drain avoiding sharp bends and pinching of the line. Install a condensate trap and prime with water. 3. During the system checkout, inspect the drain line and connections to verify proper condensate disposal. Air Filter Air fi lters are not provided as an integral part of this coil, however, a fi lter must be installed upstream of the coil and inspected frequently. When the fi lter becomes clogged with dust or lint, it should be replaced (disposable type) or cleaned (washable type). The filter should be inspected and replaced or cleaned at least twice during the year, generally at the start of each heating and cooling season. Close-Off Plates and Panels Install the necessary air close-off plates around the refrigerant lines and drain line where required. Reinstall all inner and outer panels of the coil case and furnace that were previously removed to install the indoor coil. Refrigerant Charging These cased indoor coils are not factory charged with refrigerant. It will be necessary to evacuate the indoor coil and line set prior to charging. Refer to the outdoor unit installation manual for detailed charges and instructions. 7. MAINTENANCE AND SERVICE WARNING: Ensure that all electrical power to the furnace and outdoor (condensing) unit is off before performing any maintenance or service on the system. To ensure optimum performance and to minimize possible equipment failure, the following periodic maintenance should be performed on this equipment: 1. The air filter installed with the system should be checked and cleaned or replaced twice per year. 2. Check the coil, drain pan, and condensate drain line for cleanliness at the start of each heating and cooling season. Clean as needed. CAUTION: Do not operate the system without having a suitable filter in place in the return air duct system. Always replace the filter with the same size and type. INSTALLER: PLEASE LEAVE THESE INSTALLATION INSTRUCTIONS WITH THE HOMEOWNER 7087064 7087060 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI 7087060 (Replaces 7086340) O'Fallon, MO Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A. (02/07)