m r m,-a Reprodcd 6y DOCUMENT SERVICE CENTER K OTT BUILDING, DAYTON, 2, OHIO

Similar documents
HALON FLIGHTLINE EXTINGUISHER EVALUATION: DATA SUPPORTING STANDARD DEVELOPMENT [INCLUDES NOVEMBER 2007 ADDENDUM]

EEENE. AD-AIII 4"- AIR FORCE OCCUPATIONAL AND ENVIRONMENTAL HEAL.TH LAS --ETC F/S 13/11 r

, 'I... " ENTILATION FOR SWINE / I / / I / I / UNIVERSITY OF flunois / I / SGRICULTUR~.uBRM~ '" ""'... I I \ / I I. , I \ CIRCULA~~G COpy I 1// 1\\

CIRRUS AIRPLANE MAINTENANCE MANUAL

Brine Generation Study

Secador Automatic Desiccator. vs. Comparable Competitor

GATEWAY BUILDING ELEVATOR AND ESCALATOR SERVICES

Fixed Fire Extinguishing Equipment and Systems

ARKANSAS FIRE PROTECTION LICENSING BOARD ACT 743 OF 1977

OHIO. Results of Area Campaigns Against Japanese Beetles in 0 HI 0 AGRICULTURAL EXPERIMENT STATION WOOSTER, OHIO J. B.

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

TESTS OF ADSIL COATING

A AMM - TOILET SYSTEM - DESCRIPTION AND OPERATION

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX

MAKING YOURSELF AT HOME

SMALL MOTOR CONTROLLERS

Environmental Systems

EVAPORATIVE COOLING How an Evaporative Cooler Works

CIRRUS AIRPLANE MAINTENANCE MANUAL

TOILET SYSTEM - DESCRIPTION AND OPERATION

AFRL-RB-WP-TR

THE EVAPORATION AND SPRAY SYSTEMS OF COOLING CREAM 1

Changes of phase usually involve a transfer of energy Evaporation

References: Patent Law (Article 2(3), Article 68, and Article 100) Reasons

District of Sicamous. Fire Department Bylaw No. 126, Effective Date February 26, 1996

COMPACT ADSORPTION CHILLERS WITH COATED ADSORBER HEAT EXCHANGERS

A.C.A. Tit. 20, Subtit. 2, Ch. 22, Subch. 6 Note

CHAPTER 11 AIR CONDITIONING

Definition. Temperature regulation of the human body. Function and problems of clothing

IAFF LOCAL 3499 ORMOND BEACH FIREFIGHTERS ASSOCIATION

PASSIVE HEAT EXCHANGER ANTI-FOULING FOR SOLAR DHW SYSTEMS

Investigation of Separating Small Impurities and Heavy Compounds Using the Cotton Separator Equipment

Investigation Report

Principles of Mechanical Refrigeration

The Emergence of Triboelectric Technology

AC39 Manual Water Softener Operation and Recharging

Refrigerant Installation Quick Reference Guide

TECHNICAL INFORMATION Cyanoacrylate Fuming Chamber Catalog Nos. FR200, FR200220

GASEOUS HYDROGEN SYSTEMS

BYLAW 5542 *******************************************************************************

Article 3: Police Regulated Occupations and Businesses. Division 37: Burglary, Robbery and Emergency Alarm Systems

Manure Pit Ventilation in Confinement Livestock Buildings

3.5 Cryosurface & Cryogenic Feed-through Specification

DASSAULT AVIATION Proprietary Data

CLEANING AND SANITIZING

DASSAULT AVIATION Proprietary Data

TRS TACTICAL RINSE SYSTEM. The Solution is Clear with Riveer SM MODULAR CLEAR WATER RINSE SYSTEMS FOR TAXI-THROUGH AIRCRAFT

Active Dry Air Venting for Water Contamination Control

Selecting an Environmental Test Chamber

Residential Duct Mount Builder s Box Media Air Cleaner

Agency for Health Care Administration

DOUGLAS L. BARRY FIRE CHIEF

The Firefighters Perspective

CBC s Inspection Findings and Possible Remedies Thereto

SERVICE MANUAL. For Service & Parts please call APK THERMAL at or SAFETY INSTRUCTION

Standard Operating Procedure: Outfall Inspections

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

WATER SOFTENER MODEL 801 CODE

Canadair Regional Jet 100/200 - Water & Waste

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

The Corporation of the District of North Cowichan Fire Protection Bylaw Bylaw 3340

Aerating Grain in Storage

Vol. 41, No. 5. Can. Plant Dis. Survey EXPERIMENTS ON THE CHEMICAL CONTROL OF SNOW MOLD IN TURF

ACKNOWLEDGEMENT. IIAR expresses its deepest appreciation to these authors for their contributions for the betterment of the industry.

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

Results of a high density avocado planting

SUN EQUINOX HEATING SYSTEMS

COOLING FOR ELECTRONIC PROCESS CONTROL SYSTEMS IN HOSTILE FACTORY ENVIRONMENTS

Preventative Maintenance Tables

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

Museum Archive Dehumidification in Hot & Humid Climates

Fabrication of Hot and Cold Water Dispenser

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For:

INSTALLATION AND INSTRUCTION MANUAL FOR BAC AERATION CONTROLLER

Induction Furnace Cooling Systems

Water Efficiency. Industry Specific Processes. Metal Finishing. for Commercial, Industrial and Institutional Facilities

Precipitator Solves Dryer Problem

COMPLIANCE WITH THIS PUBLICATION IS MANDATORY

Management of In-Bin Natural Air Grain Drying Systems to Minimize Energy Cost

[Docket No. FAA ; Directorate Identifier 2004-CE-25-AD; Amendment ; AD ]

Authorization to Purchase one Pierce Velocity PUC Pumper NH657 Fire Engine

CHAPTER 3 BASIC STEAM CYCLE

Control Panel For Water Wash Hoods AM2

CIRRUS AIRPLANE MAINTENANCE MANUAL

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

MultiPlex INNOVATIVE COMPRESSED AIR SOLUTIONS LARGE CAPACITY TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS

RV Safety Alarms Education Test

Guide To Troubleshooting INEFFICIENT COOLING FANS

Screw-in heater (EHK)

Section 9. Comparing Energy Consumption: More for Your Money. What Do You See? What Do You Think? Investigate. Learning Outcomes

THOMAS J. BAJZEK, P.E., CFEI PRINCIPAL, DIRECTOR OF ELECTRICAL ENGINEERING

Emergency Procedures Training

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:

Why Do I Need a Water Softener?

Trials of Vexo inhibitor in domestic central. heating systems

ROSWELL INDEPENDENT SCHOOL DISTRICT P.O. Box 1437 Roswell, New Mexico General Bid Conditions

THE DEVELOPMENT OF A GOLD WATER DEAERATOR FOR USE IN THE AFFDL 50 MEGAWATT ELECTRO" GASDYNAMIC FACILITY. Wiley C. Wells. and. Joseph M.

Merrill A. McPeak, General, USAF

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

Transcription:

Armed Services Technical Information Ugency' Because of our limited supply, you are requested to return this copy WHEN IT HAS SERVED YOUR PURPOSE so that it may be made available to other requesters. Your cooperation will be appreciated. m r m,-a NOTICE: WHEN GOVERNMENT OR OTHER DRAWINGS, SPECIFICATIONS OR OTHER DATA M~UEDI FOR ANY PURPOSE OTHER THAN IN CONNECTION WITH A DEFINITELY RELATED GOVERNMENT PROCUREMENT OPERATION, THE U. S. GOVERNMENT THEREBY INCURS NO RESPONSIBILITY, NOR ANY OBLIGATION WHAT SOEVER; AND THE FACT THAT THE GOVERNMENT MAY HAVE FORMULATED, FURNISHED, OR IN ANY WAY SUPPLIED THE SAMD DRAWINGS, SPECIFICATIONS, OR OTHER DATA IS NOT TO BE REGARDED BY IMPICAIONOR OTHERWISE AS IN ANY MANNER LICENSING THE HOLDER OR ANY OTHER PERSON OR CORPORATION, OR CONVEYING ANY RIGHTS. OR -PERMISSION TO MANUFACTURE, USE OR SELL ANY PATENTED INVENTION THAT-MAY IN ANY WAY BE RELATED THERETO. Reprodcd 6y DOCUMENT SERVICE CENTER K OTT BUILDING, DAYTON, 2, OHIO

L-a.- WADC TECHNICAL REPORT 54-94 -.. URINE EVAPORATOR VILLIAM J. McIAIL, 137 LT, USAF AERO MIDICAL LABORATORY FEBRUARY 1954 WRIGHT AIR DEVELOPMENT CENTER AAWP(S 4O,.1 41L1 5 25

WADC TECHNICAL REPORT 54-94 URINE EVAPORATOR Willam J. Mcfeil, 1st Lt, USAf Aero Medical Laboratory February 1954 S90 No. 698-29 Wright Air Development Center Air Research and Development Command United States Air Force Wright-Patterson Air Force Base, Ohio

FORKC Preliminary tests of a urine evaporator were conducted by personnel of the Aero Medical Laboratory, Directorate of Research, Wright Air Development Center, Wright Patterson Air Force Base, Ohio, in October 1951. A performance specification, Exhibit WCRDM-25, was prepared in November 1951, and shortly thereafter bid proposals for the fabrication of the first prototype were received from industry. However, it was not until November of 1952 that a contract for this development was awarded to the 0 and M Machine Company, Los Angeles, California. Performance tests on the first prototype comenced with laboratory tests in late summer, 1953. These tests were completed in November 1953, after the equipment had been in use aboard a C-47 aircraft for a period of one month. Project Engineers for this project have been R. 3. Sheete, l1t Lt, USAP; R. R. Chalquest, lt Lt, USA and W. J. McNeil, lot Lt, USAF, respectively. This project was administered under Service Engineering Order No. 699-29, "Medical and Sanitation Aircraft Equipment." WADe TR 54-94 I~.--.....

ABSTRACT lethods now in use for the disposal of urine aboard USAF aircraft include overboard drains and inboard collection tanks. Both have drawbacks, and neither is entirely satisfactory. In an attempt to overcome the deficiencies of urine disposal techniques, an assembly that evaporates urine prior to overboard venting has been designed, fabricated and tested. This urine evaporator received urine from standard relief facilities. The urine after entering the evaporator was deionized and evaporated. The vapor was vented overboard. laboratory and flight tests indicated that the use of d6ionization resins effectively removed the corrosive properties of urine. However, their use is considered to be impractical because large quantities were required for practical application. Tests further indicated that evaporation of urine does not remove its corrosiveness. Therefore, no benefits can be forseen from the use of the urine evaporator, and there are no plans for the continuation of this project. PUBLICATION REVIEW This report has been reviewed and is approved.?or THE COMMANDERs,* Colonel, USA? (NC) Chief, Aero Medical laboratory Directorate of Research iii WADC TI 54-94/ \

URINE EVAPORATOR INTRODUCTION The USA? Handboo 2t Instructions f Aircraft Designers calls for the installation of separate relief and toilet facilities aboard aircraft having a flight duration in excess of six hours. Aircraft with a flight duration of two to six hours require only relief horns. And aircraft with a flight duration of less than two hours require no sanitation facilities. It is common practice among the commercial airlines to provide toilet facilities only. Urine is removed during regular servicing of the toilets, and the installation of urinals and relief horns is eliminated. Methods of urine disposal aboard Air Force aircraft are overboard vents and inboard collection tanks. Neither method is entirely satisfactory. Drain lines and overboard vents frequently freeze and clog aboard aircraft that fly at high altitudes or in cold weather. Individuals that use relief horns and urinals with frozen drain lines experience extreme discomfort. It is also difficult to so locate the venture on high speed aircraft so that spray will not strike the fuselage or other surfaces. Urine that comes in contact with unprotected metal surfaces builds up unsightly sludge deposits and corrodes. Several corrective measures have been tried. These include use of corrosion resistant paints, frequent washing and coating with plastics. Of these, corrosion resistant paints are most commonly used. But all are time consuming procedures. At best they only inhibit corrosion. An undesirable feature of inboard collection tanks is the necessity for their periodic removal and cleaning. If not serviced frequently, these tanks can become the source of objectionable odors. Such odors have been known to contaminate crew compartments aboard tactical aircraft. HISTORY The Aero Medical laboratory, Directorate of Research, Wright Air Development Center, is investigating new approaches to the problem of inflight disposal of urine. During October, 1951, preliminary tests were conducted by Aero Medical laboratory personnel to determine the feasibility of evaporating urine and venting the vapor overboard. The purpose of these tests was to formulate plans for the development of a small evaporating assembly that WADOC TECHNICAL REPORT 54-94 1

Ao4, ho WADC TECHNICAL RIEPC RT 54-94~

would utilize cabin heated air as the evaporating medium. Tt was thought that urine after passing through an evaporator would lose its corrosive properties and, being a gas, would dissipate without striking the aircraft. Exhibit 'CRDN-25 was prepared on 19 November 1951. This exhibit described an assembly designed to receive urine from standard relief facilities. It further stipulated that the urine was to be absorbed by an expendable wick through which warm air could be passed. A 25 cubic foot/min.ute flow of 120OF air was prescribed to evaporate liquids from the wick. It was assumed that salts and other residue would remain in the wick while innoxious liquids passed overboard in a gaseous state. The developmental program was divided into four phases. included the fabrication of one test item. Each phase (1) Phase 1: One-man Assembly. (2) Phase 2: Three-man assembly. (3) Phase 3: Five-man assembly. (4) Phase 4: Nine-man assembly. The four units were to have the capacity of evaporating normal amounts of urine excreted by one, three, five, and nine men respectively with the prescribed temperature and air flow. A procurement request was initiated on 10 December 1951 for the fabrication of four evaporators. Several proposals were received and evaluated by the Wright Air Development Center, and on 17 November 1952 Contract AF 33(600)- 22516 was awarded to 0 and M Machine Company, Los Angeles, California. The one-man urine evaporator was received by the Wright Air Development Center on 13 July 1953. Due to a utilities failure, laboratory testing of the evaporator was delayed until mid August 1953. After laboratory evaluations were completed, the one-man unit was installed aboard a C-47 aircraft. Flight testing was conducted during the period of 19 October 1953 through 17 November 1953. DESCRIPTION The one-man urine evaporator built under the Air Force contract by 0 and K lachine Company consists basically of three components. These are a de-ioniuation chamber, a storage chamber, and a wick. AU these parts are circular in shape and easily accessible for inspection or servicing. The unit is approximately 13 inches outside diameter and five inches deep. Average diameter of the wick is 11 inches. The lid is attached by a V-band coupling which forms a tight seal. The do-ionization chamber contains a filter of active anion and cation exchange resins for the urine to pass through. It is easily removed and does not hinder evaporation. The resins reduce cationic and anionic properties of urine to water. They do not remove nonionic impurities. Urine, upon entering the evaporator, trickles through the do-ionization chamber and falls to the floor of the container. It then flows into the wick by capillary action. Warm air passes through the wick and evaporates the liquid before vapor is vented overboard. WADC TECHNICAL REPORT 54-94 3

L U, g 0 I i W&DC TECIIIJICAL REPORT 54-94 4

TIt ME3DMWE AJID RRSIMS laboratory evaluations began with some preliminary testing of iou exchange crystals. Testing of the first prototype urine evaporator began in the laboratory on 31 August 1953. Amberlite MB-3, an active anion-cation exchanger, was selected for laboratory evaluation. In general, results showed that fresh crystals effectively removed corrosive properties of urine. However, a large quantity of exchange crystals was needed to d-ionise appreciable amounts of urine. It was also found that Amberlite VB-3 crystals lose their effectiveness too rapidly for practical application. laboratory Data gathered on the urine evaporator included the rate of evaporation of distilled water at various air flows and temperatures. With an average air flow of 11 cubic foot/minimum and an average air temperature of 145oF, the unit evaporated liquids at rates varying from 1.25 milliliters per minute to 1.45 milliliters per minute. These conditions equaled 40 percent of the air flow and 120 percent of the temperature requirements specified in the exhibit. The unit exceeded its required evaporating capacity by 25 to 45 percent when operating under these conditions. No twine was placed in the evaporator during laboratory testing. Only the rate of evaporation of distilled water was measured. Under these test conditions the unit functioned in a highly satisfactory manner. In late October 1953, the urine evaporator was installed in the forward compartment of a C-47 aircraft for service testing. Hot air was piped to the uait from cabin heat ducts, and an overboard vent was placed approximately three feet forward and above the leading edge of the wing. (This was done to simulate the worst operating conditions, i.e. the evaporated urine would have the greatsot possibility of striking the aircraft). A relief horn that drained directly into the. evaporator was also installed. The opening of the overboard vent was placed flush with the fuselage. In this way the corrosiveness of the vapor would show its greatest effect in the shortest interval of time. The aircraft flew at irregular intervals, and during the first two weeks only 400 milliliters of urine was evaporated. No adverse effeets to either the evaporator or the aircraft was noted during this period. However, the ion exchange crystals in the evaporator became exhausted, further evidence that their use is Impractical. An estimated 2800 milliliters of urine was evaporated in the third and fourth weeks of testing. At the end of the fourth week a heavy deposit extending mix feet from the vent opening rearward was observed. This deposit of a yellbwish, gumy substance produced an unsightly streak on the aircraft body. Slight corrosion of the metal was noted. It was obvious that serious damage to the fuselage could result if the evaporator remained in use. Tests were discontinued, and the urine evaporator was immediately disconnected. WADC TECHNICAL IMPORT 54-94

low WYAD TECHNICAL REPCRT 54-946

DISCUSSION AND CONCLUSION Ion exchange crystals remove the corrosive properties of urine. But their use is limited since large quantities are required to de-ionize sufficient quantities of urine for practical use. Furthermore, they require periodic replacement or regeneration. This creates additional servicing problems. The urine evaporator designed and fabricated by the 0 and M Machine Company is well constructed, and it performed its evaporating function in a highly satisfactory manner. However, the vapor upon entering the cold air stream strikes and condenses on the aircraft surfaces. The condensate discolors and corrodes aircraft metals much like untreated urine. Use of the evaporator would require additional protective measures. Either the overboard vent would have to be located so that the condensate would not strike the aircraft or the exposed metals would have to be protected. These are the same protective measures used with the present method of direct venting. Since the evaporation of urine by air at cabin heat temperatures before venting does not prevent corrosion of exposed metal surfaces, this method of disposing urine is, therefore, considered unsatisfactory. Further development of the urine evaporator has been halted, and there are no immediate plans for the continuation of this project. However, other approaches to the problem of inflight urine disposal will be sought. WADC TECHNICAL REPORT 5I-94 7'