CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

Similar documents
CA 134. Piezoelectric accelerometer. IECEx NEPSI TIIS KGS. » From the Vibro-Meter product line» Vibration monitoring over a wide temperature

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

Gas cylinder scale Model GCS-1

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Technical Data. General specifications. Rated operating distance s n 5 mm

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

Technical Data. Dimensions

Inductive slot sensor

MODEL ACCELEROMETER

Certification Supplement Manual

INSTRUCTION & SERVICE MANUAL

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

MODEL 4000A & 4001A ACCELEROMETER

Technical Data. Dimensions

New Sensing products of Meggitt Group. Moscow - October the 23 rd

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

FDOOT241-A9-Ex Multisensor fire detector

Manual Isolating Barrier D461R1 (Revision 01)

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

OPERATION MANUAL MODEL & ACCELEROMETER

condition monitoring WP4086 Condition Monitoring System The WP4086 CMS System surveys vibrations with up to 8 external accelerometers

Technical Data. Dimensions

WP4086 Condition Monitoring System

Rosemount 3490 Series

FDCL221-Ex Line adapter (Ex)

Product ID. General. TE CONNECTIVITY SENSORS /// EXxxHyy Ex-Atex & NA 09/2017 Page 1

M7100 Pressure Transducer

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

SUBMERSIBLE Flush Diaphragm Liquid Level Sensor AST4520

Temperature Measurement Transmitters for field mounting

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

Manual Isolating Barrier D461 (Revision 05)

OPERATION MANUAL MODEL 4610 ACCELEROMETER

Technical Data. Dimensions

Certification Supplement Manual

Flameproof Manual Call Points Series MCP

MODEL 834M1 ACCELEROMETER

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Universal Tank Alarm Type Installation, Operation & Maintenance

Meggitt Sensing Systems vibration monitoring solutions. Wilcoxon Research short-form catalog

M5800 Pressure Transducer with Rotatable Display

PEPPERL+FUCHS GmbH

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

LOW PRESSURE Intrinsically Safe Transducer AST44LP

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

INSTRUCTION MANUAL (ATEX / IECEx)

Guide to Hazardous Location Approvals:

The information contained in this document is the property of Meggitt Sensing Systems and is proprietary and/or copyright material.

I/A Series 716C 1/16 DIN Temperature Controller

Meggitt Sensing Systems Monitoring the future

OLC(T) 100 FIXED GAS DETECTOR

OOH740-A9-Ex Multi-sensor fire detector

OOH740-A9-Ex Multisensor fire detector

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

HYTEK ATEX APPROVED BUND ALARM

Druck DPI 705/DPI 705 IS Series

OPTIBAR P 1010/2010 C Supplementary instructions

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

DB5 Intrinsically Safe Sounder Type DB-5

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Assembly. Host Sub-D Alarm

Model 144H. Product Data Sheet , Rev DB February Content

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Dräger Polytron 5100 EC Detection of toxic gases and vapors

M5200 Industrial Pressure Transducer

OPERATION MANUAL MODEL 805 ACCELEROMETER

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Indoor/outdoor resistance thermometer Model TR60

1592P01. for liquids in piping DN

U5300 Industrial Pressure Transducer

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Model 144H. Product Data Sheet , Rev DB February Content

DB4 Range - SPEAKERS - Up to 25 Watts

M5800 Pressure Transducer with Rotatable Display

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

DICTATOR Hold-Open Systems for Hazardous Areas

VQ500 Series Combustible Gas Detector Elements

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

UL HAZARDOUS LOCATIONS SERVICES

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

INTRINSICALLY SAFE LIGHTING RANGE

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

Transcription:

Piezoelectric accelerometer with integrated electronics FEATURES» From the Vibro-Meter product line» Designed for medium temperature industrial applications: 55 to 115 C» Sensitivity: 100 mv/ g» Frequency response: 2 Hz to 10 khz» Ground isolated from case» Sealed for harsh environments: IP67 protection rating» Certified for use in potentially explosive atmospheres IECEx DESCRIPTION The is an all-purpose vibration sensor designed for use with machinery in harsh industrial environments and hazardous areas (potentially explosive atmospheres). The output signal has a sensitivity of 100 mv/ g. It uses the industry standard 2-wire voltage transmission technique with a constant current supply. Information contained in this document may be subject to Export Control Regulations of the European Union, USA or other countries. Each recipient of this document is responsible for ensuring that transfer or use of any information contained in this document complies with all relevant Export Control Regulations. ECN N/A. Meggitt SA / 262-050 / Version 1 / 11.04.2017 / E 1 / 5

SPECIFICATIONS Note: Unless otherwise stated, all values listed are typical values, referenced at 23 C (73 F), 24 V DC supply, 6 ma constant current and 120 Hz. Operating Sensitivity : 100 mv/ g ±10 % (at 80 Hz) Dynamic range : 80 g Transverse sensitivity : < 5 % Linearity : < 1 % up to full-scale Frequency response (nominal) 2 Hz to 10 khz : ±5 % 0.8 Hz : 3 db Resonant frequency (nominal) : 18 khz Temperature response (typical deviation) 55 to 115 C ( 67 to 239 F) : ±10 % 55 C ( 67 F) : 10 % 115 C (239 F) : +10 % Electrical Input supply current Supply voltage for current source Bias voltage (nominal) Residual electrical noise (maximum) Output impedance (nominal) Grounding Reversed polarity : 0.5 to 8 ma : 18 to 30 V DC : 12 V DC : 0.1 mg : 150 Ω : Base isolated : Protected Environmental Temperature range : 55 to 115 C ( 67 to 239 F) Protection rating : IP67 (according to IEC 60529) Sinusoidal vibration limit : 1000 g peak Shock limit : 7000 g peak Base strain sensitivity (maximum) : 0.0005 g peak / µε Electromagnetic sensitivity (equivalent) : 50 µg / gauss 2 / 5 Meggitt SA / 262-050 / Version 1 / 11.04.2017 / E

SPECIFICATIONS (continued) Potentially explosive atmospheres Available in Ex approved versions for use in hazardous areas Type of protection Ex i: intrinsic safety Europe EC type examination certificate Baseefa 16 ATEX 0027 X II 1 GD (Zones 0, 1, 2) Ex ia IIC T4 Ga Ex ia IIIC T135 C Da International IECEx certificate of conformity IECEx BAS 16.0030X Ex ia IIC T4 Ga Ex ia IIIC T135 C Da For specific parameters of the mode of protection concerned and special conditions for safe use, refer to the Ex certificates that are available from Meggitt SA. For the most recent information on the Ex certifications that are applicable to this product, refer to the Ex product register (PL-1511) that is available from Meggitt SA. Approvals Conformity : CE marking, European Union (EU) declaration of conformity Environmental management : RoHS compliant Hazardous areas : Ex (see Potentially explosive atmospheres on page 3) Physical Dimensions : See Mechanical drawing on page 4 Weight : 100 g (0.22 lb) approx. Case material : Stainless steel Mounting : 1/4-28UNF stud or adaptor Mounting torque : 8 N m Output connector : MIL-C-5015 type, 2 pin Pin A+ : Power supply and output signal Pin B : Common Mating connector : MIL-C-5015 type such as MS3106F10SL-4S or MS3456L10SL-4S Recommended cables : See Accessories on page 5 Calibration Dynamic calibration at factory. No subsequent calibration necessary. Meggitt SA / 262-050 / Version 1 / 11.04.2017 / E 3 / 5

MECHANICAL DRAWING accelerometer Adaptor studs 5/8-24UNEF-2A Connector mates with MIL-C-5015 13.5 8 M8x1 MARKING 52 6.3 9.5 1/4-28UNF-2B Ø 22.2 Pin B Pin A+ 25 Hex. 4 / 5 Meggitt SA / 262-050 / Version 1 / 11.04.2017 / E

ORDERING INFORMATION To order please specify Type Designation Ordering number Piezoelectric accelerometer VMD CE110 I ACCESSORIES Supplied Item Adaptor studs Type 1/4-28 UNF 1/4-28 UNF to M8x1 Optional Item Type Part number Cables EC 318 922-318-000Dxxx EC 319 922-319-000Dxxx Mounting adaptor MA 122_012 809-122-000-012 1/4-28 UNF to M6 (with conic base) Insulating stud MA 122_021 809-122-000-021 1/4-28 UNF to M6 (with conic base) Headquartered in the UK, Meggitt PLC is a global engineering group specializing in extreme environment components and smart sub-systems for aerospace, defence and energy markets. Meggitt Sensing Systems is the operating division of Meggitt specializing in sensing and monitoring systems, which has operated through its antecedents since 1927 under the names of ECET, Endevco, Ferroperm Piezoceramics, Lodge Ignition, Sensorex, Vibro-Meter and Wilcoxon Research. Today, these operations are integrated under one strategic business unit called Meggitt Sensing Systems, headquartered in Switzerland and providing complete systems, using these renowned brands, from a single supply base. The Meggitt Sensing Systems facility in Fribourg, Switzerland was formerly known as Vibro-Meter SA, but is now Meggitt SA. This site produces a wide range of vibration and dynamic pressure sensors capable of operation in extreme environments, leading-edge microwave sensors, electronics monitoring systems and innovative software for aerospace and land-based turbo-machinery. All statements, technical information, drawings, performance rates and descriptions in this document, whilst stated in good faith, are issued for the sole purpose of giving an approximate indication of the products described in them, and are not binding on Meggitt SA unless expressly agreed in writing. Before acquiring this product, you must evaluate it and determine if it is suitable for your intended application. Unless otherwise expressly agreed in writing with Meggitt SA, you assume all risks and liability associated with its use. Any recommendations and advice given without charge, whilst given in good faith, are not binding on Meggitt SA. Meggitt Sensing Systems takes no responsibility for any statements related to the product which are not contained in a current Meggitt Sensing Systems publication, nor for any statements contained in extracts, summaries, translations or any other documents not authored by Meggitt Sensing Systems. We reserve the right to alter any part of this publication without prior notice. In this publication, a dot (.) is used as the decimal separator and thousands are separated by thin spaces. Example: 12 345.678 90. Sales offices Your local agent Head office Meggitt Sensing Systems has offices in more than 30 countries. For a complete list, please visit our website. ISO 9001 FS 584089 ABCD Meggitt SA Route de Moncor 4 PO Box 1616 CH - 1701 Fribourg Switzerland Tel: +41 26 407 11 11 Fax: +41 26 407 13 01 www.meggittsensingsystems.com www.vibro-meter.com Meggitt SA / 262-050 / Version 1 / 11.04.2017 / E 5 / 5