INSTALLATION, OPERATION AND SERVICE MANUAL MIGHTY ION MODEL MI SERIES

Similar documents
INSTALLATION AND OPERATIONS MANUAL

INDUSTRIAL ELECTROSTATIC AIR CLEANER MODEL: SH-SSP-300

Electronic Air Cleaner Model Number CSC1000 OWNER S MANUAL. Installation Operation Basic Service Guide Technical Repair Guide Repair Parts

Installation Operation Maintenance

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

READ AND SAVE THESE INSTRUCTIONS. Air Boss Model T5200 Custom Packaged Electronic Air Cleaner. TRION

OPERATION & MAINTENANCE MANUAL MODEL SC SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

Eliminator Series. SE400E and SE800E ELECTRONIC AIR PURIFICATION SYSTEM. Electrostatic Precipitators for Commercial Applications

INSTALLATION MANUAL. '»'"',' ','"* Self-contained Ceiling Mount Electronic Air Cleaner.

lectronic Air Cleaner

AIR CLEANER A GUIDE TO OPERATING AND MAINTAINING YOUR ELECTRONIC. NOTE TO INSTALLER: This manual should be left with the equipment owner.

OPERATION INSTRUCTION

Operation And Maintenance Manual MODEL SSC-7 SEMI-FLUSH CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

READ AND SAVE THESE INSTRUCTIONS. SE400E & SE800E Smoke Eliminator. TRION

Infrared Portable Space Heater

Electronic Air Cleaner

IONIZING AIR BLOWER INSTRUCTION MANUAL

Installation, Start-up and Service Instruction ELECTRONIC AIR CLEANER

T-Series Air Conditioner T15 Model

HEATER. Fan Forced IMPORTANT INSTRUCTIONS READ & SAVE OWNER S MANUAL. Model No.: DR W 120V 60Hz DR W 240V 60Hz

PACKAGED ELECTRONIC AIR CLEANER. Air Boss T-Series. Model T5200 INSTALLATION OPERATION SERVICE. Electrostatic Precipitator for Industrial Applications

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

TABLE OF CONTENTS HOW AIRBORNE CONTAMINATION IS REMOVED 3 DIMENSIONS 4 SPECIFICATIONS 6 PLANNING THE INSTALLATION 7 ASSEMBLY & INSTALLATION 10

READ AND SAVE THESE INSTRUCTIONS. Air Boss ATS Series Electrostatic Precipitators Commercial & Industrial Applications. TRION

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Service Manual. Model Number: Compact Fireplace DF203A DF2006. UL Part Number to 800

Gallery Electric Fireplaces

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

The Family Ceramic Heater

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

PARTS & SERVICE MANUAL

Service Manual 23 Compact Fireplace Model Number: DF2305

Decon Scrubber Owner s Manual

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

T-Series Air Conditioner T53 Model

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Eagle 2500 TM OWNER S MANUAL. Electronic Air Purification 110 and 220 volt Systems. EcoQuest International. Application.

PARTS AND SERVICE MANUAL FOR. DIMPLEX PURIFIRE ELECTRIC STOVE Model TDS8515

T1001 Module T2002 Module T1300 T2600. Air Boss T-Series Custom Packaged Electronic Air Cleaner READ AND SAVE THESE INSTRUCTIONS

T-Series Air Conditioner T20 Model

BEFORE OPERATING, READ ALL INSTRUCTIONS IN THIS MANUAL CAREFULLY.

Warranty. Installation Operation Maintenance

Duct Mount Electronic Air Cleaner

TROUBLESHOOTING VANGUARD

HE Plus 1400 HE Plus 2000 Duct Mount Electronic Air Cleaner

18E ELECTRIC FAN HEATER

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

Infrared Portable Space Heater

PERSONAL SIZE FIREPLACE

Dr. Infrared Heater Elite Series

ELECTRIC FLAT PANEL FIREPLACE HEATER

E1.5 ELECTRIC FAN HEATER

- 1 - Updated on 18 March, 2010

Infrared Portable Space Heater

IMPORTANT SAFETY INFORMATION

ELECTRIC STOVE HEATER Models: FS2213B

40E ELECTRIC FAN HEATER

Instruction Manual FEEL THE ENERGY. FEEL THE FRESHNESS.

IMPORTANT SAFETY INFORMATION

IMPORTANT INSTRUCTIONS READ & SAVE

OVHM80 Max Air Purifier

IMPORTANT SAFETY INFORMATION

SPECIFICATIONS - IMPORTANT -

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 02_04 FA SP-ENG OM - 02_04

Convection Panel Heater

IMPORTANT SAFETY INFORMATION

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

Living Air Electronic Air-Purification Systems

- 1 - Updated on 18 March, 2010

Quartz 2 in 1 Convection and Radiant Heater Model : HQ12-15M

Electric Patio Heater Ceiling Type. Operating Instruction. WARNING: This heater is not equipped with a device to control

Wall Mount Electric Fireplace

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

Electric Garage Heater

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

IMPORTANT INSTRUCTIONS OPERATING MANUAL

F116 (Series 16000) Self-Contained Ductable Commercial Air Cleaner

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

Homeowner s Installation Instructions & Operating Manual

BF5000NT BF5000 EF2604 SF2603 DF2603

With Remote Control. English

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

OWNER S MANUAL ELECTRIC FIREPLACE INSERT. Model No.: WESTERN (EF42D-45D) WARNING CAUTION

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

THE flectiionic Alii CLEANER ' --- OIL MIST CONTROL UNITS

Installation, Operation & Maintenance

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Important: Read all instructions and warnings carefully before starting installation. INSTALLATION INSTRUCTIONS GENERAL

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

Transcription:

1135 Lance Road Norfolk, VA 23502-2429 Telephone: 757-461-0077 a.k.a. Universal Air Precipitator Corporation Telefax: 757-461-0808 Quality Equipment and Service Since 1962 email: info@uapc.com INSTALLATION, OPERATION AND SERVICE MANUAL MIGHTY ION MODEL MI SERIES www.uapc.com MANUFACTURER/DESIGN OF AIR & GAS COMPRESSOR SYSTEMS, ELECTROSTATIC PRECIPITATOR SYSTEMS AND RELATED CONTROLS AND ACCESSORIES

TABLE OF CONTENTS 1. OPERATING PRINCIPLE 2. ELECTRICAL CIRCUIT 3. STEPS FOR INSTALLATION A. Determine Location of Precipitator B. Connect Water Wash 4. ELECTRICAL REQUIREMENTS A. No Meter Reading B. Circuit Breaker Switch Trips Off 5. MAINTENANCE 6. PREPARATION FOR CLEANING 7. CLEANING FREQUENCY 8. CLEANING PROCEDURE 9. SOAK-WASHING 10. TROUBLE SHOOTING A. Power Pack Difficulty B. Collecting Cell Difficulty C. Insulator Difficulty D. Meter Reading E. Circuit Breaker Occasionally Trips Off F. Constant or Intermittent Arcing 11. WIRING DIAGRAM AND PARTS LIST

1. OPERATING PRINCIPLE The Universal Air precipitator is composed of four (4) basic components: the ionizing section, the collecting section, the power pack and blower. The first two combine to form the collecting cell. The collecting cell(s), within the air cleaner housing, is ahead of the air moving unit. The dirt particles, carried by the air, pass first through the ionizing section where a high-voltage direct current charge is applied. All dirt particles, as they pass through the ion field, acquire a negative charge. These charged particles then pass into the collecting plate section where an additional electrical field then repels the charged particles to alternately-spaced ground collector plates. Periodically, the collecting cell(s) and mechanical filters must be removed for cleaning. The power pack converts 115 or 220 volts AC to Direct Current. 2. ELECTRICAL CIRCUIT In the primary circuit, 115 or 220 volts, 60 Hertz, single phase, AC enters the power pack through a safety switch that is mechanically operated by the screw retaining the power pack cover, then through a circuit breaker which is used as an on and off switch and which will trip off in the event of a short in either the power pack or the collecting cell. In series is a variable rheostat which is used to obtain the proper operating range. Turning the rheostat slot clockwise increases the operating range and counterclockwise decreases the operating range. When the power pack cover is removed, it opens the safety switch to prevent shock from contact with the circuit. The primary power enters a transformer which produces the necessary voltage for the operation of the precipitator. In series from the transformer is a rectifier which converts the AC output of the transformer to DC. Connected across the DC is a fixed resistor which bleeds off the charge when the circuit is de-energized. A meter in the DC circuit measures the current of the collecting cell(s). Each Universal Air precipitator model has a specified operating range.!! CAUTION!! (I) (ii) The power pack must be grounded when being bench tested. Discharge the secondary circuit with an insulated handle screwdriver before touching any of the components. 3. INSTALLATION A. Determine Location of Precipitator The Mighty Ion can remove only those particles that reach its collecting element(s). It is, therefore, important that the unit(s) are installed near the source of heavy pollution approximately five (5) feet from the inlet. In the case of multiple units, they should be spaced approximately forty (40) feet apart, depending upon the CFM capacity of the units. The unit(s) should be positioned so as to provide a perimeter movement of air. The output of each unit should be directed into the intake of the next unit. If the room is wider than seventy-five (75) feet, it may be necessary to install additional units through the center portion of the room or provide circulation to disperse the air to its perimeter. Airflow should not be directed into heater discharge.

DO NOT locate the air cleaner inlet too close to the corner of a room. Air will bypass the unit and not be cleaned. DO NOT locate the air cleaner outlet too close to a corner or wall. The air will bounce back and restrict recirculation. Whenever space permits, the unit(s) should be hung approximately six (6) feet from the wall and approximately ten (10) feet from the floor using the eye bolts provided. It is better, however, to have a rigid mount for the unit(s) for ease of maintenance. A minimum of twenty-seven (27 ) inches must be provided for collecting cell removal clearance. B. Connect Water Wash For Mighty Ions equipped with an integral water wash system, run a hot water line with a readily accessible hand service valve, to the precipitator water wash manifold. The was water should be approximately 125 o to 140 o F. Install drain assembly (2 IPS). The pipe size should not be reduced from the precipitator drain. A trap must be provided to prevent sewer gas and odor from being drawn into the system. 4. ELECTRICAL REQUIREMENTS The precipitator power pack is equipped for 115V or 220V, single phase operation only. The blower motor can be operated on 115V. Plug in the primary cord. The precipitator is ready for operation by turning the blower switch and power pack circuit breaker on. With the power pack circuit breaker on, the indicating light will glow and the meter will register a reading. If the meter registers above or below the specified range, turn the rheostat adjustment screw to obtain the required meter reading. If a malfunction prevails, it will be indicated by the meter or the circuit breaker switch will trip off. A. No Meter Reading 1. Primary power is not being supplied to the power pack. 2. The power pack safety switch is not activated. 3. High voltage lead is not attached to the panel insulator. B. Circuit Breaker Switch Trips Off 1. Meter reading set too high. 2. Bent or warped collector plate. 3. Foreign metallic object between collector plates. 5. MAINTENANCE Effective air cleaning performance requires regular cleaning of the collecting cells. Prefilters usually require cleaning at the same time. CAUTION: The precipitator collecting cell(s) is a delicate instrument and should be handled gently. Avoid grasping the cell at the plate section or setting it any protruding objects. A bent or warped collecting plate will cause arc frequently and reduce its performance. on the cell to 6. PREPARATION FOR CLEANING Unscrew the time delay screw from the safety interlock box. Unlatch the cell access door and discharge the collecting cell with an insulated handle screwdriver. Remove collecting cell.

7. CLEANING FREQUENCY Cleaning of the collecting cell will vary from one installation to another, depending on many application-related factors. For most common applications, cleaning frequency is from once a week to once a month or when the precipitator begins to arc frequently. With a heavy dirt loading, more frequent washing will usually be required. If a very heavy build-up of dirt is found on the collecting cell(s) after washing, they should be washed more frequently. A wash reminder schedule should be posted after a frequency schedule is established. 8. CLEANING PROCEDURE The best cleaning procedure is usually soak-washing. Recommended cleaning compounds, depending on the character of the contaminant collected, vary. Regular commercial dishwasher detergent is effective in many cases. As an alternate, the standard cleaners used on plant and process equipment may be used if they are inhibited to be safe with aluminum. If the collected contaminant is a dry dust or powder, it can adequately be cleaned by rapping the collecting cell against the side of a dust bin or blowing off the dust with a blast of compressed air. Eventually, it will become necessary to provide a soak-washing. Detergent steam can also be used effectively or a detergent solution under pressure. 9. SOAK-WASHING Provide a suitable soaking container large enough to hold at least one collecting cell completely immersed in solution. Hot water should be used to readily dissolve the selected detergent suitable for local water conditions. CAUSTIC cleaners CANNOT be used. They will destroy the aluminum. Soak the collecting cell and mechanical filters in the dissolved solution for approximately twenty (20) minutes. After soaking, slosh the collecting cell and mechanical filters to remove loosened dirt. Length of soaking should be determined by quantity and tenacity of dirt build-up. Rinse the collecting cell and mechanical filters thoroughly to remove all traces of detergent and allow to drip dry. Examine the collecting cell for broken ionizer wires or bent collector plates, and then replace the cell in the precipitator housing. At this time, it is advisable to clean the insulator which supports the high voltage jumper. Turn on the blower and power pack. If the collecting cell arcs, turn off the power pack and allow the blower to thoroughly dry the collecting cell(s). (A spare collecting cell will eliminate any downtime of the precipitator.)

10. TROUBLE SHOOTING!! CAUTION!! (I) (ii) The power pack must be grounded when being bench tested. Discharge the secondary circuit with an insulated handle screwdriver before touching any of the components. A malfunction is indicated by either an erratic meter reading or the circuit breaker switch will trip off. The difficulty can be isolated to either the power pack or the collecting cell, as follows: (a) (b) (c) (d) (e) (f) Remove power pack cover. Disconnect the high-voltage lead by removing the nut at the through-panel insulator. Pull the high-voltage lead away from any point of contact. Turn range adjustment full clockwise. Turn on circuit breaker switch. Depress the safety switch button and hold for a couple of minutes. If the circuit breaker switch trips off, the difficulty is in the power pack. It if does not trip off, the difficulty is in the collecting cell. The exception would be a defective rectifier. A. Power Pack Difficulty 1. Defective Transformer - To check this possibility: a. Disconnect the secondary lead of the transformer from the insulator to which it is attached and pull it away from any point of contact. b. Turn the rheostat full clockwise. c. Depress the safe switch button. If the circuit breaker trips off, the transformer is defective. Check all primary leads for any bare wire and avoid having them lay across the highvoltage lead or rectifier. 2. Defective Rectifier - With the cell connected (assuming there is no cell difficulty) and the range adjustment turned full counterclockwise, a faulty rectifier will generally allow a partial meter reading but will begin to fade toward zero. If the faulty rectifier does not trip off the circuit breaker within a few minutes a quick check can be made, after de-energizing the circuit, by touching the rectifier. If it is hot, it is failing. A failing rectifier can only be checked by comparison with a known good rectifier. For example, if you had a meter reading of 0.5 with a questionable rectifier and you replaced it with a good rectifier, you would immediately obtain a high meter reading. 3. Defective Meter - A defective meter can be somewhat confusing, but if it registers full scale with a minimum rheostat adjustment, or if it barely moves off the zero position without tripping the circuit breaker, it can be assumed to be defective. Generally speaking, a quarter turn on the rheostat is sufficient to provide the desired secondary voltage. 4. Defective Bleeder Resistor - It will appear blistered or corroded and cause a high meter reading.

5. Defective Rheostat - The winding will be open. Turning the rheostat from the full counterclockwise position, no voltage will be supplied to the transformer until you reach a point beyond the break in the winding when suddenly there is too much voltage. The over-voltage will cause the collecting cell to arc or the circuit breaker to trip off. 6. Defective Capacitor - A defective capacitor will cause erratic behavior of the meter or circuit breaker. Its defect is generally revealed by a ruptured case or traces of oil. The unit will function satisfactorily without the capacitor. B. Collecting Cell Difficulty - Trouble in the collecting cell may be the result of one or more of the following: 1. Collecting cell still wet after washing. 2. Broken or loose ionizing wire(s). 3. Foreign object between collector plates. 4. Extremely dirty collecting cell. 5. Bent or warped collector or end plates. 6. Cracked or porous insulators in collecting plate section. This condition would develop after washing. An OHM meter, in some instances, may provide a reading. 7. On multi-cell units, the jumper must be between the cells. C. Insulator Difficulty - A cracked or porous insulator may cause a ticking sound, cause the meter needle to flick or to read high. The defective insulator can be isolated by energizing the unit for several minutes and touching the insulators. The defective insulator will become warm. 1. A defective stand-off insulator in the power pack can be determined by removing the screw from the ground side. The screw will be corroded. D. Meter Reading 1. A zero meter reading would indicate that primary power is not being supplied or that the safety switch is not actuated. 2. A zero meter reading, or a slight flicker, before the circuit breaker trips off is caused by a defective transformer. 3. A partial or near normal reading before the circuit breaker trips off is caused by: a. Defective rectifier b. Insulator starting to fail 4. A high meter reading before the circuit breaker trips off is caused by: a. Defective insulator b. Foreign object between collector plates c. Broken or loose ionizing wire d. Rheostat adjustment set too high E. Circuit Breaker Occasionally Trips Off 1. Voltage set too high 2. High line voltage during the night hours 3. Insulator starting to fail 4. Coated ionizing wires

F. Constant or Intermittent Arcing 1. Operating range higher than required 2. Loose or defective ionizing wire 3. Excessively dirty collecting cell 4. Bent or warped collecting plate 5. Cracked or porous insulator 6. Coated ionizing wires

POWER PACK WIRING DIAGRAM AND PARTS LIST 1 - Safety Switch 5 - Rectifier 2 - Rheostat 6 - Bleeder Resistor 3 - Circuit Breaker 7 - Milliammeter 4 - Transformer 8 - Capacitor