GLOBAL FLOW PRODUCTS

Similar documents
In-Line Air Separators

Pressure Vessels BT Series Replaceable bladder expansion tank with bottom system connection

TECHNICAL. Series 18. Pump Packages

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

Peerless Pump Company

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008

ASME Packaged Indirect Fired Water Heater

EXTROL EXPANSION TANKS

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

InterSeptor Centrifugal Separators Operating & Maintenance Manual

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

ASME and Non-ASME Storage Vessels

Packaged Steam Fired Water Heater

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters

High Capacity Instantaneous Steam Fired Water Heater

Indirect Fired Water Heater

Cemline Steel Tanks. Carbon Steel, Stainless Steel, Galvanized Steel, Copper A.S.M.E. Code, Non-Code

Silhouette. Feedwater Heater. Boiler Feedwater

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Threaded. Flanged. Model PSH. Primary Secondary Header A-451

Taco 00 Series Cartridge Circulators

University of Delaware

5. CONDENSATE PUMPS/UNITS

Hard-hitting Contenders In HVAC Fluid Handling Solutions

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

The Ultimate in Distribution Efficiency. Air Eliminator Dirt Separator Low Loss Header Hydraulic Separator

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Wilo IL Vertical Split-Coupled Inline Pumps

SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

.2 Section Waste Management and Disposal..5 Section Performance Verification of Mechanical Piping Systems.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

A. This Section includes the following domestic water piping specialties:

D Series. Single Tower Deliquescent Dryers FEATURES. No power required. No moving parts. Low pressure drop. 20ºF to 63ºF dew point suppression

DOLPHIN FRESH WATER SHELL AND TUBE EVAPORATOR

Systems and Tanks. 40 H/V 60 H/V 80 V 115 V 139 V Gallon. Applications Sizing System Design

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

ASME Packaged Electric Water Heater

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

YALE Site Specifications AIR VENT SCHEDULE

Division 23 - HVAC Switzerland Beallsville K-12. Section HYDRONIC PIPING SECTION HYDRONIC PIPING PART 1 - GENERAL

Liquid Drainers LIQUID DRAINERS

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION HYDRONIC PIPING

Boiler System Expansion Tanks

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Domestic Pump Condensate Transfer Equipment

Nirvana. Cycling Refrigerated Dryers

Davies Carries Parts for MF & SF Series Glycol Feeders

470 Series Stamped Stainless Steel Pumps

B. Shop Drawings: Detail fabrication of pipe anchors, hangers, special pipe support assemblies, alignment guides, expansion joints and loops,

Nirvana Cycling Refrigerated Dryers

THERMAL EXPANSION ABSORBERS

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

Thermal Devices Inc. Mount Airy, Maryland USA Process Air and Radiant. ADH Typical Installation.

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

Suggested Specifications Prestige Excellence 110

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

BuildingName The Description of the Project P DOCUMENTS

Semi-Instantaneous Indirect Fired Water Heater

CALEFFI. SEP4 combination hydraulic, air, dirt and magnetic separator series 01249/13.1 NA. Replaces 01249/13 NA. Function.

Water Piping and Pumps

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

AIR SENTRY DESICCANT BREATHERS

MODEL P. 2 ft. NPSH Cast Iron Bronze Fitted Low NPSH Centrifugal Pumps. BULLETIN 112 Revised 7/09. PH (Horizontal Flange Mounted)

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Packaged Semi-Instantaneous Steam Fired Water Heater

SINCE Heat Exchangers. Plate and Frame FFW AHRI. Shell and Tube W & S. Brazed FFB cat-2016-he

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

THERM-X-TROL THERMAL EXPANSION ABSORBERS. The Best Solution for Controlling Thermal Expansion. As Seen On

SB Series Brazed Plate Heat Exchanger Installation Manual

Series 1140 and 1141 Temperature Regulators

FUEL-FIRED VERTICAL TUBELESS BOILERS

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

Tepid Water Delivery System

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

UNIVERSITY OF MISSOURI Building Hydronic Piping and Pump Systems 2017 Q3

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

Pipe: ASTM B88, hard drawn copper, Type K. Fittings: ASTM B16.22 Wrought copper and copper alloy.

SECTION ELECTRIC WATER HEATERS

CALEFFI. dirt separator series 01137/16 NA. Replaces 01137/15 NA. Product range. Technical specifications

SECTION PLUMBING EQUIPMENT

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

SPH Series. Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters CEMLINE CORPORATION

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Section H11 BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...H11-3 PRODUCT OFFERING...H11-3 SAMPLE SPECIFICATIONS...H11-11 ILLUSTRATIONS

Hydronic Specialties and Circulator Pumps

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Hoffman Specialty Pump Products

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

LOCAL INVENTORY FOR QUICK SHIPMENT

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

Transcription:

ir Control Products 866-204-5229 GLOL FLOW PODUCTS

Tanks for Hydronic Systems ladder Tanks merican Wheatley offers a large range and several styles of bladder type expansion tanks. The Wheatley WF Series, SME, full acceptance, top entry bladder tanks are offered in sizes from 36 gallon through 10,000 gallon. The WF is SME rated 150 psi through 220 gallon, and is SME rated for 125 psi through 10,000 gallon The WF is standard with a heavy duty replacement butyl rubber bladder. Tanks can be trimmed for potable water. The Wheatley DT Series, SME, bottom entry, full acceptance bladder tanks are offered in sizes 13 gallon through 211 gallon. The DT series is SME rated for 150 psi, and is standard with a replaceable EPDM bladder. Tanks can be trimmed for potable water. WF Series The Wheatley WF Series, SME, bottom entry full acceptance bladder tanks are offered in sizes 220 gallon through 10,000 gallon. The WF series is SME rated for 125 psi, and is standard with a replaceable heavy duty butyl bladder. Tanks can be trimmed for potable water. ll merican Wheatley DT, WF, and WF SME tanks are standard with a replaceable bladder that is suitable for hydronic and domestic water services. ll merican Wheatley SME bladder tanks are POUDLY MDE IN THE US. What is the function of the Tank in a Hydronic System? The tank could arguably be considered the most important component part to the hydronic DT Series system. The tank allows for thermal expansion within the hydronic heating or cooling system. The tank absorbs the expansion and contraction of system fluid due to changes in system temperature. Whether the tank is a bladder type, which contains the system fluid inside the bladder, isolating it completely from the air and prevents waterlogged tanks, or the plain steel type which absorbs the expansion while mixing the air and water, merican Wheatley has the correct tank for your application. DT Series vailable in sizes 13-211 gallon Full acceptance removable and replaceable heavy duty butyl rubber bladder Suitable for potable water 150 PSI SME Constructed and stamped WF Series vailable in sizes 36-10,000 gallon Full acceptance removable and replaceable heavy duty butyl rubber bladder NSF approved bladder 150 PSI through 220 gallon, larger sizes 125 PSI SME Constructed and stamped WF Series vailable in sizes 36-10,000 gallon Full acceptance removable and replaceable heavy duty butyl rubber bladder NSF approved bladder 125 PSI SME Constructed and stamped Options vailable 175, 200, 250, 300 higher working pressures Epoxy coated or S.S. covers for potable water ulls eye sight glass Seismic clips Mounted on legs Horizontal mounted 2

SME ladder Type Expansion Tanks Standard Features: emovable and replaceable heavy-duty butyl rubber bladder Full cceptance Series for large expanded fluid volumes SME constructed and stamped. National oard registered Standard design pressure 150 PSI through WF 800. WF 1000 and above 125 PSI. Optional Features: Higher working pressures available Epoxy-coated covers for potable water California sight glass Seismic mounting WF Series DT Series MODEL GLLON SIZE-INCH MODEL GLLON SIZE-INCH MODEL GLLON SIZE-INCH WF-140 36 20 x 39 1/2 DT-013 13 14 X 28 WF-140 36 20 X 42 WF-215 57 20 x 54 DT-016 16 14 X 32 WF-215 57 20 X 58 WF-300 82 24 x 57 1/8 DT-026 26 16 X 40 WF-300 82 24 X 61 WF-450 120 24 x 78 DT-040 40 20 X 41 WF-450 120 24 X 81 WF-600 165 30 x 69 DT-060 60 24 X 48 WF-600 165 30 X 73 WF-800 220 30 x 88 DT-080 80 24 X 50 WF-800 220 30 X 91 WF-1000 271 36 x 79 1/2 DT-112 112 30 X 52 WF-1000 271 36 X 81 5/8 WF-1200 324 36 x 91 DT-135 135 30 X 59 WF-1200 324 36 X 91 1/4 WF-1400 377 36 x 104 DT-162 162 30 X 61 WF-1400 377 36 X 105 5/8 WF-1600 440 48 x 78 1/8 DT-185 185 30 X 80 WF-1600 440 48 X 80 WF-2000 550 48 x 90 1/8 DT-211 211 32 X 71 WF-2000 550 48 X 94 WF-2500 660 48 x 102 WF-2500 660 48 X 94 WF-3000L 792 48 x 122 WF-3000 792 54 X 86 WF-4000 1056 60 x 102 WF-4000 1050 54 X 132 WF-5000 1320 60 x 125 WF-5000 1320 60 X 110 WF-7500 1980 72 x 127 WF-6000 1590 60 X 140 WF-10000 2640 72 x 159 WF-7500 1980 60 X 174 WF-15000 3963 72 x 233 WF-8000 2100 72 X 134 WF-20000 5250 72 x 240 WF-10000 2640 72 X 159 1 1/2 Inlet System Connect Charging Valve Lifting ing ir Charge Valve ir Charge Valve etaining Nut Lifting ing 1 1/2 FNPT for optional ulls Eye WF Lifting ing Standard design pressure 150 PSI Maximum design temperature 240 F with utyl ladder DT-006 & DT-009 System Connection ir Charge Valve System Connection DT-040 THU DT-211 WF System Connection DT-013, DT-016 & DT-026 3

ir Separation ir is the single worst enemy to any hydronic heating system. Entrained air being present in any hydronic system can cause a myriad of problems, from cold areas due to the system being air bound, to premature equipment failures due to rust, scale, and corrosion. There are two ways to remove air from the system, by the use of an air scoop and by use of a centrifugal type separator. Centrifugal Type The other most common type of air separator is also relatively simple in design and is commonly known as a centrifugal force type. This type of air separator utilizes tangential openings to create a centrifugal action required to create a vortex at the center of the vessel. The air, being lighter than water, is forced to the center of the vortex and rises to the top opening in the air separator where it is vented to atmosphere or directed to the expansion tank. This type of air separator also allows for a smaller vessel to be utilized than is required for a low velocity type. merican Wheatley offers our TS Series less strainer and our TSS Series with removable stainless steel strainer. The TS and TSS are available in sizes 2 through 30. s centrifugal force spins the air entrained water around the outside of the vessel, the air molecules are forced to the center of the vortex created, rises to the top of the vessel and is expelled through the air vent either to atmosphere or to a specified tank. While the operation seems simple, it is a must for all hydronic systems. merican Wheatley offers a tangential design that is constructed and stamped in accordance with SME VIII, Division 1. They are also National oard registered and recognized. merican Wheatley tangential air separators are available in sizes 2 through 30 with standard carbon steel construction. The merican Wheatley Tangential air separator is also available with an optional, removable, stainless steel strainer with 3/16 perforations. Standard construction of 2 through 8 is rated 150 psi, 10 and larger are rated 125 psi. Higher pressure ratings are available. merican Wheatley air separators are also available in stainless steel construction. Consult factory for pricing. SME Tangential ir Separators (less strainer) Features: SME Construction and stamped 8 and under 150 P.S.I. working pressure 10 and larger 125 P.S.I.-working pressure MNPT inlet & outlet on 2 & 2 1/2 3 and larger flanged inlet & outlet Grooved end connections available 32 and above units available upon request Standard units are skirt mounted for vertical floor installation Ceiling and seismic mount available upon request TS Series 4

PT NUME INLET & OUTLET (IN.) (IN.) C (IN.) D (IN.) E (IN.) F (IN.) G (IN.) H (IN.) I (IN.) WEIGHT TS002 2 12 19 1/2 25 1/8 16 5/8 5 1/2 4 5/16 1 1 10 1/4 40 TS025 2 1/2 12 19 1/2 25 1/8 16 5/8 5 1/2 4 1/16 1 1 10 1/4 44 TS003 3 12 19 1/2 25 1/8 19 5 3 1 1 10 1/4 52 TS004 4 14 29 34 5/8 21 9 1/8 4 1/4 1 1/2 1 1/2 12 1/4 94 TS005 5 14 29 34 5/8 21 9 1/8 3 1 1/2 1 1/2 12 1/4 116 TS006 6 20 41 46 5/8 28 13 1/4 6 1/4 1 1/2 1 1/2 17 1/4 201 TS008 8 20 41 46 5/8 28 13 1/4 5 3/16 1 1/2 1 1/2 171/4 296 TS010 10 30 58 63 9/16 41 19 9 1/8 2 2 26 1/4 560 TS012 12 30 58 63 9/16 41 19 8 1/8 2 2 26 1/4 665 TS140 14 36 75 1/2 80 46 3/8 22 10 3/16 2 2 32 1/2 910 TS160 16 48 100 108 60 30 12 1/2 2 2 45 2,200 TS180 18 54 116 124 66 33 13 5/8 2 2 1/2 51 1/2 2,500 TS200 20 60 130 138 72 35 16 2 2 1/2 58 5/8 3,800 TS240 24 72 152 162 84 40 19 2 2 1/2 69 5/8 7,000 TS300 30 72 152 162 86 38 19 7/8 2 2 1/2 69 5/8 7,450 SME Tangential ir Separators (with strainer) Features: SME Construction and stamped 8 and under 150 P.S.I. working pressure 10 and larger 125 P.S.I.-working pressure MNPT inlet & outlet on 2 & 2 1/2 3 and larger flanged inlet & outlet Grooved end connections available 30 and above units available upon request Standard units are skirt mounted for vertical floor installation Ceiling and seismic mount available upon request Quick access to strainer for maintenance TSS PT NUME INLET & OUTLET (IN.) (IN.) C (IN.) D (IN.) E (IN.) F (IN.) G (IN.) H (IN.) I (IN.) WEIGHT TSS002 2 12 19 1/2 22 1/2 16 5/8 5 1/2 4 5/16 1 1 10 1/4 48 TSS025 2 1/2 12 19 1/2 22 1/2 16 5/8 5 1/2 4 1/16 1 1 10 1/4 58 TSS003 3 12 19 1/2 22 1/2 19 5 3 1 1 10 1/4 70 TSS004 4 14 29 32 21 9 1/8 4 1/4 1 1/2 1 1/2 12 1/4 108 TSS005 5 14 29 32 21 9 1/8 3 1 1/2 1 1/2 12 1/4 136 TSS006 6 20 41 44 28 13 1/4 6 1/4 1 1/2 1 1/2 17 1/4 236 TSS008 8 20 41 44 28 13 1/4 5 3/16 1 1/2 1 1/2 17 1/4 356 TSS010 10 30 58 60 1/2 41 19 9 1/8 2 2 26 1/4 660 TSS012 12 30 58 60 1/2 41 19 8 1/8 2 2 26 1/4 870 TSS140 14 36 75 1/2 80 46 3/8 22 10 3/16 2 2 32 1/2 1,220 TSS160 16 48 100 108 60 30 12 1/2 2 2 45 2,700 TSS180 18 54 116 124 66 33 13 5/8 2 2 1/2 51 1/2 3,000 TSS200 20 60 130 138 72 35 16 2 2 1/2 58 5/8 4,000 TSS240 24 72 152 160 84 40 19 2 2 1/2 69 5/8 5,500 TSS300 30 72 152 162 86 38 19 7/8 2 2 1/2 69 5/8 8,000 5

Sediment emoval merican Wheatley also offers a centrifugal type sediment removal separator. While the design is similar to the merican Wheatley TS Series air separator, the SS sediment removal separator also offers the advantage of solids removal. The tangential design allows for sediment removal through the vortex action, which forces suspended sediment to the outside of the vessel and into the bottom sump where it can be easily removed. The tangential action also creates a vortex that forces entrained air into the center, which is then removed through the top opening, vented to the atmosphere or sent to the expansion tanks. Features: Carbon Steel Construction SME design and stamped Standard Design Pressure 125 PSI emoves Sediment and Entrained ir Tangential Design ottom sump and drain Higher Pressures available Larger sizes available ir Scoop / ir Purgers The merican Wheatley S Series air scoop operates on the premise that air will rise in the piping and then into air scoop, being directed to the top opening and out of the system through an air vent or to an expansion tank. Since proper operation of this type of air separator is also dependant on velocity, sizing this type of air separator is a function of proper flow rate. This type of air separation is best suited for residential and light commercial applications. merican Wheatley S Series air scoops are readily available from stock. Features: vailable in heavy cast iron construction in sizes 1 to 3, 4 through 12 are fabricated carbon steel flanged units Taps are provided for expansion tank and air vent connection Maximum working pressure of 125 PSIG Maximum operating temperature of 450 F 6

ir & Dirt Separator-Standard & High Velocity The merican Wheatley HVD high velocity and STD standard velocity, coalescing type air & dirt Separator is intended for use on commercial HVC, Institutional, and industrial applications to remove entrained air and particulate from the system water. merican Wheatley utilizes a coalescing media consisting of 304SS high performance saddle rings. ll merican Wheatley are designed and constructed to SME Section VIII, Division 1 standard. The merican Wheatley HVD & STD series coalescing type air & dirt separator is capable of removing 99.6% free air and 99% of the measurable entrained and dissolved air with continuous circulation. Solids to 20 microns can be eliminated within 100 passes continuous circulation. Features: Constructed in accordance with SME Section VIII, Division I, Latest Edition Carbon Steel Construction Primed Exterior 8 and under 150 P.S.I. working pressure 10 and larger 125 P.S.I. working pressure MNPT inlet & outlet on 2 & 2 1/2 3 and larger flanged inlet and outlet Grooved end connections available 32 and above units available upon request Standard units are skirt mounted for vertical floor installation Dia Flange to Flange Options: Stainless Steel Construction Other lloy Construction Higher pressures available Painted surface top coat / Epoxy coats Magnetic Insert Ceiling clips/seismic clips C C- emovable Cover Dia For automatic air removal, we recommend adding our high capacity air vent part V. Flange to Flange C N- Non emovable Cover 7

Standard Velocity with Non emovable Cover FLNGE TO FLNGE SUFCE E OPTIML PIPE SIZE MODEL NO. DI. (INCH) (INCH) (INCH) C (INCH) D (INCH) (SQ. FT.) WEIGHT (LS) FLOW (GPM) 2 STD-2-N 14 24 13/16 6 15 21-64 85 50 2.5 STD-2.5-N 14 24 13/16 6 15 21-3/8 39 90 75 3 STD-3-N 14 28-7/16 6 15 21-1/4 51 100 115 4 STD-4-N 14 28-7/16 6 15 24 51 110 190 5 STD-5-N 20 39-13/16 6-18- 30 106 190 300 6 STD-6-N 20 39-13/16 6-18- 30 106 205 440 8 STD-8-N 24 47-1/4 7-1/16 21-1/16 34-5/8 187 430 750 10 STD-10-N 30 59-7/16 7-13/16 25-13/16 41-1/4 300 600 1200 12 STD-12-N 30 59-7/16 7-13/16 25-13/16 42-300 650 1700 14 STD-14-N 36 77-13/16 8-1/2 34-1/2 49-5/8 600 870 2040 16 STD-16-N 36 77-13/16 8-1/2 34-1/2 51 600 870 2599 Standard Velocity with emovable Cover FLNGE TO FLNGE SUFCE E OPTIML PIPE SIZE MODEL NO. DI. (INCH) (INCH) (INCH) C (INCH) D (INCH) (SQ. FT.) WEIGHT (LS) FLOW (GPM) 2 STD-2-C 14 27-1/8 6 15 21-38 265 50 2.5 STD-2.5-C 14 27-1/8 6 15 21-3/8 38 270 75 3 STD-3-C 14 30-11/16 6 15 21-1/4 51 280 115 4 STD-4-C 14 30-11/16 6 15 24 51 290 190 5 STD-5-C 20 44-1/16 6-18- 30 106 520 300 6 STD-6-C 20 44-1/16 6-18- 30 106 535 440 8 STD-8-C 24 52-1/2 7-1/16 21-1/16 34-5/8 187 870 750 10 STD-10-C 30 64-9/16 7-13/16 25-13/16 41-1/4 300 1000 1200 12 STD-12-C 30 64-9/16 7-13/16 25-13/16 42-300 1050 1700 14 STD-14-C 36 82-15/16 8-1/2 34-1/2 49-5/8 600 1523 2040 16 STD-16-C 36 82-15/16 8-1/2 34-1/2 51 600 1553 2599 High Velocity with Non emovable Cover FLNGE TO FLNGE SUFCE E OPTIML PIPE SIZE MODEL NO. DI. (INCH) (INCH) (INCH) C (INCH) D (INCH) (SQ. FT.) WEIGHT (LS) FLOW (GPM) 2 HVD-2-N 14 31-11/16 10-15/16 27-15/16 21-65.1 99 108 2.5 HVD-2.5-N 14 31-11/16 10-15/16 27-15/16 21-3/8 65.1 103 163 3 HVD-3-N 14 39-1/8 10-15/16 31-21-1/4 80.6 119 249 4 HVD-4-N 14 39-1/8 10-15/16 31-24 80.6 128 432 5 HVD-5-N 20 56-1/2 11-15/16 41-11/16 30 162.2 253 685 6 HVD-6-N 20 56-1/2 11-15/16 41-11/16 30 162.2 270 988 8 HVD-8-N 24 68-1/16 12-1/8 48-7/8 34-5/8 287 519 1714 10 HVD-10-N 30 84-13/16 12-58-3/16 41-1/4 455 736 2698 12 HVD-12-N 30 84-13/16 12-58-3/16 42-455 783 3831 14 HVD-14-N 36 101-15/16 12-5/8 66-7/8 49-5/8 798.1 1101 4623 16 HVD-16-N 36 101-15/16 12-5/8 66-7/8 51 798.1 1124 6039 High Velocity with emovable Cover FLNGE TO FLNGE SUFCE E OPTIML PIPE SIZE MODEL NO. DI. (INCH) (INCH) (INCH) C (INCH) D (INCH) (SQ. FT.) WEIGHT (LS) FLOW (GPM) 2 HVD-2-C 14 34-1/16 10-15/16 27-7/8 21-64.8 281 108 2.5 HVD-2.5-C 14 34-1/16 10-15/16 27-7/8 21-3/8 64.8 283 163 3 HVD-3-C 14 41-9/16 10-15/16 24-21-1/4 78.7 300 249 4 HVD-4-C 14 41-9/16 10-15/16 24-24 78.7 308 432 5 HVD-5-C 20 60-13/16 11-15/16 42-11/16 30 159 587 685 6 HVD-6-C 20 60-13/16 11-15/16 42-11/16 30 159 598 989 8 HVD-8-C 24 73-1/4 12-1/8 48-7/8 34-5/8 282.2 958 1714 10 HVD-10-C 30 90-1/8 12-58-3/16 41-1/4 448.9 1129 2698 12 HVD-12-C 30 90-1/8 12-58-3/16 42-448.9 1179 3831 14 HVD-14-C 36 108-1/2 12-5/8 66-7/8 49-5/8 787.6 1658 4623 16 HVD-16-C 36 108-1/2 12-5/8 66-7/8 51 787.6 1689 6039 8

Chilled Water uffer Tanks Diameter Optional Features: Manway, Hand hole Higher Pressures Stainless Steel Construction Upper Mounted System Connections Height Center affle Construction Performance Limitations Carbon Steel Max Design Temp: 450F Exterior Primer Painted Max Design Press: 125 PSI Center-line Height ( in inches) for various Connection DI. HGT Face to MODEL GL (IN.) (IN.) 2 NPT 2 1/2 3 FLG 4 FLG 6 FLG 8 FLG 10 FLG 12 FLG Face WCT-120 120 24 60 12 12.25 12.50 13 14 15 16 17 36 WCT-200 200 30 72 14 14.25 14.50 15 16 17 18 19 42 WCT-300 300 36 72 15.75 15.75 16 16.50 17.50 18.5 19.5 20.50 48 WCT-400 400 36 99 24 24 24 25 26 27 28 29 48 WCT-500 500 42 90 17.50 17.75 18 18.5 19.50 20.5 21.5 22.50 54 WCT-750 750 48 106 18.75 19 19.375 19.875 21 21.875 23.5 24.5 60 WCT-850 850 54 96 21 21.25 21.50 22 23 24 25 26 66 WCT-1040 1040 60 96 22.75 23 23.25 23.75 24.75 25.75 26.75 27.75 74 DESCIPTION: merican Wheatley SME Chilled Water uffer Tanks are designed for chilled water systems with insufficient water volume capacity, in relation to the chiller capacity. elatively low water volume systems require additional buffer capacity for the system to eliminate problems such as excessive chiller cycling, poor temperature control, and erratic system operation. The properly sized merican Wheatley CT tank adds the necessary volume to buffer the system. TYPICL SPECIFICTIONS: Furnish and install as shown on plans, an SME Chilled Water uffer Tank as manufactured by merican Wheatley HVC Products. The tank shall in corporate a baffle to promote tank water storage temperature stratification. The system water connections must be inch (NPT/flanged/grooved). The tank must be constructed in accordance with most recent addition of Section VIII of the SME oiler and pressure Vessel Code. Each Chilled Water uffer Tank shall be merican Wheatley Model WCT-. Dimensions are subject to change without notice, please confirm actual dimensions with factory at time of order. F2F Drain 9

Series HS Hot Water Hydraulic Separator/uffer Tanks merican Wheatley HS Series Hot water buffer tanks are designed to operate with modern high efficiency low-mass modular boiler systems. The merican Wheatley hot water buffer tank ensures minimal T and provides the necessary thermal storage to prevent short cycling that could occur during low load conditions. Prevents flow in one circuit from interfering with flow from another circuit Eliminates the need for a primary loop circulating pump, air separator, and strainer, thereby reducing initial cost as well as operating cost Eliminates complicated piping, reduces labor and piping costs Sized for no more than 4 fps, low velocity in the vessel results in low pressure drops Correctly installed hydraulic separation allows the use of multiple circulators to operate independently without interfering with each other Ideal for multiple load systems merican Wheatley manufactures SME hydraulic separators in standard sizes 2 through 14, SME 125 Larger sizes and pressure ratings readily available C Typical Specifications Furnish and install an merican Wheatley HS series, vertical hydraulic buffer tank as described on the drawings or schedule. Inlet and outlet connections shall be flanged unless otherwise noted. Unit shall be constructed of carbon steel and built in accordance with SME Section VIII, Division 1, the nameplate manufacturer shall carry all applicable SME certificates. Exterior shall be primer base coated. MODEL Vent Drain C Weight Optimal NO. SIZE GLLON Diam. (In.) Overall Height (In.) (In.) (In.) Flange to Flange (Lbs.) Flow GPM HS-002 2 9 12 26 NPT 46 65 HS-025 2.5 14 12 36 24 48 65 HS-003 3 36 16 48 28 87 178 HS-004 4 36 16 48 28 90 178 HS-005 5 65 20 57 32 410 300 HS-006 6 100 20 84 32 426 520 HS-008 8 235 30 90 1 1/2 42 700 800 HS-100 10 450 36 118 1 1/2 48 1,200 1,200 HS-120 12 500 42 97 1 1/2 54 1,400 1,400 HS-140 14 500 42 97 1 1/2 54 1,450 1,750 10

Series HSC Coalescing Type Hydraulic Separator merican Wheatley HSC Series Coalescing type Hydraulic Separators/Hot Water uffer Tanks are designed to operate with modern high efficiency low-mass modular boiler systems. The merican Wheatley HSC Series ensures minimal T and provides the necessary thermal storage to prevent short cycling that could occur during low load conditions, along with the added benefit of a coalescing media for superior air and dirt separation. C Prevents flow in one circuit form interfering with flow from another circuit Eliminates the need for a primary loop circulating pump, air separator, and strainer, thereby reducing initial cost as well as operating cost Eliminates complicated piping, reduces labor and piping costs High performance stainless steel ring type coalescing media Correctly installed hydraulic separation allows the use of multiple circulators to operate independently without interfering with each other Ideal for multiple load systems. merican Wheatley manufactures SME hydraulic separators in standard sizes 2 through 14, SME 125 Larger sizes and pressure ratings readily available Typical Specifications Furnish and install an merican Wheatley HSC series, coalescing type vertical hydraulic separator as described on the drawings or schedule. Inlet and outlet connections shall be flanged unless otherwise noted. Unit shall be constructed of carbon steel and built in accordance with SME Section VIII, Division 1, the nameplate manufacturer shall carry all applicable SME certificates. Coalescing media must be stainless steel. Exterior shall be primer base coated. MODEL NO. HSC-40 HSC-120 HSC-200 HSC-300 HSC-400 SIZE GLLON Q STT DIN VENT 2, 2.5, 3 4 40 2, 2.5, 3 4 120 2, 2.5, 3 4 200 2, 2.5, 3 4 300 2, 2.5, 3 4 400 14 24 30 36 36 58.75 65.25 69.31 73.63 96.63 C 29.38 32.63 34.63 36.82 48.31 D 6.60 6.60 6.60 6.60 6.60 E 14.75 18.53 19.56 21.75 21.75 F 42.38 41.38 43.38 43.38 66.38 G 26 36 42 48 48 WT 200 440 630 730 800 Custom built Products merican Wheatley HVC Products can custom fabricate all types and sizes of specialty products and pressure vessels to meet your specifications. Many options of material construction available. 11

Typical Piping Details With ladder Type Tanks (WP/WF Series) Typical Piping Details With Plain Steel Tanks (WPS Series) From oiler ir elease Valve Wheatley educing Valve Cold Water Supply Footring Wheatley Expansion Tank Gauge Glass Opening Sight-gauge available Strainer emoval SME Wheatley ir Separator Drain Wheatley educing Valve Drain Cold Water Supply From oiler SME Wheatley Expansion Tank To System Pump Strainer emoval SME Wheatley ir Separator Drain To System Pump Commitment To ring You The est With more than 37 years experience, Wheatley brand products have established a reputation for providing dependable products to the HVC industry. The Plugaroo/TDV is an industry standard. In addition to our complete line of tanks, strainers and valve products, we are committed to bringing you the latest in HVC technology from all over the world. This commitment is your assurance of receiving the best products the industry has to offer. Other merican Wheatley HVC Products: utterfly Valves Non-slam Check Valves Silent and Dual Disc Styles SME elief Valves Pressure educing Valves Tank Fittings and Tank Drains Custom Tanks Chilled Water uffer Tanks Dual Control Valves ir Scoops Flow Test Kits ir elease Valves all Valves utomated Quarter Turn Valves Specialty ir Separators Fabricated Products MIN OFFICE 2701 W. Concord Street roken rrow, OK 74012 Toll Free: 866-204-5229 PH: 918-317-0401 FX: 918-317-0407 www.wheatleyhvac.com e-mail: sales@globalflowproducts.com 03-18