Wireless PIR Detector Installation Handbook

Similar documents
Wireless PIR Detector Installation Handbook

Masthead Repeater Installation Handbook

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant

Genesis system configurations Handbook. Issue 3.

Quick Reference. Product Guide. Wired PIR Systems for CCTV and Lighting. Wireless PIR Systems for CCTV and Lighting

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

Movement Detector GJD 300

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

D-Tect 2 GJD300 Quad PIR Movement Detector

D-TECT 3 IP. GJD260 IP Motion Detector

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

D-TECT 2 IP. GJD230 IP Motion Detector

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System

5000 INSTALLATION GUIDE

Installation Manual Premier Elite Orbit QD/DT INS483-2

1125 PIR Motion Detector

Architectural and Engineering Specification for a Real-Time Locating System Flare

D-TECT Dual Tech. GJD360 Triple Technology External Detector

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

G.M. Advanced Fencing & Security Technologies Ltd

Architectural and Engineering Specification for a. Flash / Flare

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

SRT321 User and Installation Instructions

1126 Series Ceiling Mount PIR Motion Detector

SMARTWALK DEMENTIA WANDERING SYSTEM

SCS311 / SCS317 Installation Instructions

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

Wireless Call Point ( )

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications.

Home Doorway Alert Kit

Panel XTO210/610/710 GPRS

HDCVI PIR Camera User s Manual

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

DATA CENTER SECURITY. March 2017 Anton Panaitescu

2G & 3G GSM Portable PIR Alarm

IN A BOX. User Manual YOUR HOME SECURITY SYSTEM. curv360.co.uk. Support APP remote arm/disarm, parameter settings and accessories management

Wireless security products

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Advanced DIGITAL Wired PIR Motion Detector

Web Services are based on Apache and Tomcat servers. The html/jsp (tags, beans) are fully customisable and extendable.

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Sensors. Supplied by: User Interfaces. Networked Controls Product Catalogue

FLOOD SERIES DATA SHEET

English. Italiano. Português. Françias. Español

UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION. All in One - All in Touch Video - Alarm System

HRX Technical Manual. Version 1.2

The WAVE Plus Instant Notification System for Schools and Colleges

BATTERY POWERED DETECTOR/ TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTXDCB INSTRUCTIONS

READ ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual

User Guide. HTM Nurse Call. In the event of requiring assistance, please contact your Installer/Supplier.

GUARDIAN : AUTOGUARD. User Manual

WIRELESS NETWORK USER MANUAL MHz RFT-868-PIR Wireless Passive Infrared Sensor

arm wire free solutions nurse call personal security fire alarms

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

Ontech GSM 9040/50. Reference Manual English -1 -

Ion Gateway Cellular Gateway and Wireless Sensors

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

Security made in Germany

Networked Access Control Panel. Installation Guide

Consultant Specification AGILE Wireless Fire Detection System

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

Fratech Multipath-IP

RVRC Training Manual Fast Trace Installer Menu

High-End Wireless Security

Description Supervised Wireless Technology PRODUCT SPECIFICATION SHEET

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

Description. Optex Incorporated

Fiber Optic Cable Fence Disturbance Sensor

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

600 Range Dialer Installation Manual. Version 1.0

Common Questions & Answers

Totally Wireless Video Security

External Wireless Sounder

Lightning Warning System: LWS MK-II. User's Guide. KOREA EMI Technologies Co.,Ltd , Jangam-ri, Majang-myeon, Icheon-si, Gyeonggi-do, Korea

setting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS NFS EN 54-11

Intrusion Outdoor Protection Perimeter

ADPRO PRO Passive Infrared Detector. Webinar November Ben Klösen, PLM

UNC100 Integra Manual

ALARM SECURITY PRODUCTS

Inner Range FE3000S. Serial GSM Modem. P/No: INSTALLATION MANUAL

PERMACONN PM1030 Includes DI300. Installation Manual

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Upgrade of PSTN network Alarm System

Product Data Sheet. Remote Terminals. Features:

Fire / CO Alarm Interface

Panel XT210/610/ Description. Supervised Wireless Technology

WIRELESS SOLUTIONS FOR RESIDENCES. A Group brand

- Basic information of Laser Scan detector

FIRERAY 5000 range USER GUIDE

COMMUNICATOR ET08 / ET081

E529 Smart Digital Thermostat Product Guide

CentaurPlus ZW and HRT4-ZW

Silent Alert Fire Safe System

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL

EviKontroll Silo. Monitor Your Grain Anytime, Anywhere

Network Camera. Quick Guide DC-T1233WHX. Powered by

Transcription:

Luminite Genesis product range Wireless detectors G1 Wireless s 30m x 20m LGWP3020 G1 Wireless s 15m x 20m LGWP1520 G1 Wireless s 40m x 4.5m LGWP4004 G1 Wireless s 12m Horizontal curtain LGWP12HC G1 Wireless s 12m Vertical curtain LGWP12VC G2 Wireless s 30m x 20m LG2WP3020 G2 Wireless s 60m x 4m LG2WP6004 Wireless Accessories IP Masthead/Repeater LGIP MT434 Masthead/Repeater LGMT434 Masthead Relay Unit LGMRU4x4 Relay Expansion Module LGREM4x4 IP Masthead with Relays LGIP MRU4x4 Walk Test Instrument LGWT434 16 way relay unit LGRU16 Relay module LGRM8 16 way relay unit with end of line resistor LGRU16ELR 3 versions Relay module with end of line resistor LGRM8ELR 3 versions High efficiency antenna for mastheads AE434 Magnetic version of the above AE434 MAG Transmitter module LGTX434 Wireless Remote Set/Un-Set Key Point LGKSQ Test transmitter for G2 hard wired detectors LG2TM434 Hard wired detectors G1 Wired s 30m x 20m LGHW3020 G1 Wired 15m x 20m LGHW1520 G1 Wired 40m x 4.5m LGHW4004 G1 Wired 12m horizontal curtain LGHW12HC G1 Wired 12m vertical curtain LGHW12VC G2 Wired s 30m x 20m LG2HW3020 G2 Wired s 60m x 4m LG2HW6004 Wireless Detector Installation Handbook Type: LGWP-15/40/HC/VC Issue 11 2a BELLEVUE ROAD, FRIERN BARNET, LONDON, N11 3ER Tel: 0044 (0) 208 368 7887 Fax: 0044 (0) 208 368 3952 LUMINITE ELECTRONICS LTD, 2a BELLEVUE ROAD, FRIERN BARNET, LONDON, N11 3ER Tel: 0044 (0) 208 368 7887 Fax: 0044 (0) 208 368 3952 Web: www.luminite.co.uk email: sales@luminite.co.uk

PRE-INSTALLATION NOTES Unpacking On receipt, inspect the package and contents for signs of damage. If damage has occurred, advise the carrier and/or suppliers immediately. Inspect the contents to confirm that all items are present and undamaged. If any items are missing or damaged, contact the supplier immediately. It is advisable that the original carton is retained as this forms the safest transport container in the event that a unit has to be returned for any reason. Servicing This unit should not require general servicing. Any repair work should only be undertaken by qualified service personnel. Moisture Do not expose the internal electronics of this unit to moisture i.e. take care during installation or when changing batteries not to allow rain or damp into the product. When the product is sealed it is water resistant to IP67. Box Contents 1 x GENESIS wireless detector 1 x 1/4 wave antenna 1 x sun shield 2x C cell alkaline batteries (May already befitted in detector) 4 x no 8 wall plugs 4 x no 8 2 screws 1 x 3 mm hexagonal key LGWP Wireless Detector Specification. Suitable for BS8418 systems. Grade 2 EN50131-1 Lens types Mounting height Alarms & tampers Compensation Batteries Battery life RF output RF range Encoding Call In 15 metre x 90deg 40 metre x 1deg Horizontal curtain 12 metre 90 deg Vertical curtain 12 metre 90 deg 1.5-4metres Detection / Anti Tamper / Anti Cloaking / Shock/3 Axis inertia Day light and temperature compensation 2 x 1.5 volt alkaline C cells 2 years approximately. ( Depending on number of activations) 434.525Mhz 10m/w 1 Km line of sight Rolling code Every 60-80 seconds Enclosure 3 mm polycarbonate (except for Fresnel lens and wall bracket) IP rating 67 Temperature range 10 to +60 deg C Copyright 2016 Luminite Electronics Ltd All rights reserved. Unauthorised duplication of this handbook by any means mechanical or electrical, is strictly prohibited without the express written permission of Luminite Electronics Ltd. Luminite Electronics Ltd acknowledge all registered trademarks Luminite Electronics Ltd reserve the right to make changes to this handbook and to its products without prior notice in order to improve design or performance characteristics. Types of tamper Front cover micro switch Activated when the cover screw is removed. Shock sensor Piezo sensor detects physical attack of the product. Anti masking Active IR and LDR sense when the front window/lens is obscured. LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 2 LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 19

INDEX page Introduction & How the system works 4 Wireless Genesis System using LGRU16 to interface to NVR s, DVRs and Alarm Panels 5 Lens patterns 6 Positioning, Fixing & Connecting the Batteries 7 Codes & Functions explained 8 Sub Nets with Repeaters 9 Programming 10 Wireless transmission code settings and functions 11 functions 12 Adjustment, Antenna connection & Sun shield 13 Site survey testing 14, 15 Types of receivers 16, 17 Specification 19 LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 18 LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 3

Introduction The LGWP range of wireless Passive Infra Red Detectors () have been designed to meet the newest and most demanding requirements of the CCTV market. These detectors provide the versatility of wireless whilst meeting and surpassing the requirements needed for a BS8418 system. Inside the is a powerful microprocessor which uses a combination of fuzzy logic and look up tables to determine the validity of an activation. With this technology nuisance alarms are greatly reduced. The also contains a shock sensor and light sensor to enhance it s anti-tamper features which now include physical attack and anti-cloaking. A thermal sensor adjusts the parameters of the in extremes of heat and cold to maintain optimum performance. Currently four popular lens patterns are available to cover most situations. (See page 5). A further two special lenses are planned for the near future. The continuously poles in to verify that it is operational. Every time it transmits it also sends other information such as battery condition as well as pulse count settings and software revision number. How the system works At the heart of the system there is a Masthead which receives the data transmitted by the detectors. See Fig 1. Each time a (1) detects movement it transmits data to a masthead (2). This masthead then does two things. Firstly it re-transmits the data and attaches a text string to it which can be received by either a Pager (LGP434) or Walk Test Instrument (LGWT434). (3). These devices will display the ID number and name of the such as Main Gate etc. The walk test unit shows additional information such as the s battery status, pulse count setting and software version as well as the signal strength at the masthead. The second thing that the masthead does is to pass data via an RS232 link to an alarm system such as the LGMRU4x4 (4) Luminite relay unit configurable as 4 alarm & 4 tamper relay outputs or 8 alarm outputs without tampers. Alternatively the LGRU16 (5) relay control unit with up to 64 alarm relay outputs and a further 64 tamper relay outputs may be connected in the same way. This control unit keeps a log of events and provides text for video insertion. Alternatively, the masthead may be connected directly to some popular DVR/ transmission systems (6) thus illuminating complex and costly wiring. Masthead LGIP-MT434 This transceiver is similar to the standard LGMT434 but with the addition of IP connectivity. IP connectivity enables local plug and play connectivity with selected Alarms, DVR's and NVR's as well as a host of remote monitoring software solutions. The IMMIX platform is one of the first to be integrated using the robust SMTP protocol. In addition to this another connection can be opened to provide client TCP/IP connection to the alarm system or DVR/NVR using a selectable protocol depending on the make or manufacture of the product. Panasonic is one of the latest integrations which provides direct communication with up to three PTZ cameras per. The IP Masthead is future proofed by way of a 'Boot Loader' front end that allows remote upgrades of firmware as new releases become available. IP Configurator is a free download from our web site and enables the Masthead to be remotely configured for the appropriate alarm interface as well as installing Masthead firmware updates. A new feature enables up to three email addresses to be configured that will receive alerts such as 'low battery', 'missing call', 'tamper's & alarms'. IP integrations include: Bi3 Dahua Eyelynx Heitel Hikvision IMMIX Mobotics Panasonic Videcon LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 4 LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 17

Types of Receivers (Transceivers) The Genesis Masthead receivers are in actual fact transceivers meaning that they can transmit as well as receive. This feature enables them to act as a repeater to relay information on to another masthead and also send information to the walk test instrument. There are currently three types of Masthead as follows: LED s 1 & 2 Auxilary terminals BNC socket Top board Standard antenna Cable gland Masthead LGMT434 This masthead can be used it s own as a Repeater or can connect to a relay unit such as the LGRU16. It will also interface directly with some third party DVR s and alarm systems without the need for a relay unit. The LGRU16 relay control unit will provide up to 16 relay alarm outputs together with 16 Tamper relay outputs. Four of these units will provide the maximum of 64 relay outputs. * * * * Alarm Contacts RS232 and Power 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Bottom board LED s 1 & 2 12 volts In & RS232 out socket BNC socket BNC plug Cable gland Standard antenna * * * * Masthead Relay Unit LGMRU4x4 The masthead relay unit does everything that a masthead unit can do but also provides 4 alarm and 4 tamper relay outputs. A switch change converts the product to an 8 alarm output without tampers if required. This model is primarily intended to connect directly to a dome camera s pre-set inputs but may also be used to connect to DVR s and alarm systems where a smaller number of relay outputs are required. LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 16 Wireless Genesis System using LGRU16 to interface to NVR s, DVRs and Alarm Panels This typical example shows how the wireless detectors transmit to the LGMT434 Masthead Receiver, which in turn passes the alarm information via a wired link to the Alarm Relay Control Unit LGRU16 which monitors all the s and reports missed call-ins, low battery conditions etc. The LGMT434 Masthead Receiver is normally placed on the outside of the building where it can get the best reception from the transmitters As standard the LGRU16 Alarm Relay Control Unit is supplied with 8 alarm and 8 tamper outputs. It can be expanded up to 16 alarm and 16 tamper outputs by adding an extra module called an LGRM8. These alarms are provided by relay contacts and will interface with virtually any alarm system. LGRU16 control units can be connected together to provide up to 64 outputs. Each alarm output comprises of five coloured ribbon wires. These are made up of common, normally open and normally closed contacts for the alarm and a pair of normally closed contacts for the tamper. LGWP series Wireless detectors Fig 1 LGIP MT434 Masthead transceiver (Passes information to control unit) Features: Up to 64 detectors per system Full supervision from call-ins Battery voltage monitoring Easy relay interface to popular makes of DVR and alarm panels One tamper relay for each alarm relay LED display for alarm events LGRU16 (Alarm Relay Control Unit) Up to 4 control units may be connected together to provide up to 64 outputs. Connection to control Interface using 4 core alarm cable. (RS232) Alarm panel or DVR Ethernet to the world wide web. Walk Test Instrument LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 5

Lens Patterns The LGWP detector is available currently in four detection patterns. 15m x 90deg. 40m x 1deg. 12m vertical curtain. 12m horizontal curtain. ( See diagrams). These lenses are not interchangeable and the correct lens type must be decided before installation. A further two special lenses are planned for the near future. LGWP-1520 LGWP-4004 Step 4 Testing with a Walk test Instrument. Hang the detector on the wall bracket and walk about within the detection area using the Walk Test Instrument. The test instrument will display the unit code and bleep each time detection takes place. In filter mode it will ignore all other unit codes on the site and only respond to the detector under test. Other information will also be displayed such as signal strength and Tamper, Shock and Cloak alarms. NB: The Cloak detection will only work during day light and is not instantaneous. To test this, ensure the detector has been in position for at least 5 minutes and then cover the lens with a bag. After a few minutes the detector will send a Cloak message. Anti Tamper will indicate if the detector is opened. To test the Shock sensor, strike the detector hard with something like the handle of a large screwdriver. Do not hit the Fresnel lens as this may easily be damaged. Step 5 Angle adjustment. There are three angle adjustment screws which must be slackened before the detector can be adjusted to the correct position. Once correct area coverage has been achieved, lock the angle adjustment screws tightly. Finally ft the top and bottom screws to the wall plate to prevent it from being lifted off the wall bracket. If a sun shield is required, fit this in place before fitting the antenna. LGWP-12HC LGWP-12VC LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 6 LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 15

Site survey testing It is recommended that a Walk Test Instrument (LGWT434) should be used to accurately test and set the detectors up. A Masthead should be fitted to enable a full range test of the system. Step 1 Install a Masthead transceiver in a suitable position where it can easily be connected to the NVR, DVR or alarm system. The Masthead should also be positioned where it will get the best radio reception from detectors all around the site. An optional antenna (AE434) is available which will greatly improve radio reception. A temporary test may be made quickly just by connecting a 12 volt battery to the masthead and placing it in it s intended position. Decide on a SITE Code from one of the 32 codes available and set it on the Masthead. Set the SUB NET Code to 1. Switch the Masthead into Walk Test Mode. See Masthead installation and operating instructions for full details. Step 2 Set the same SITE Code on the Walk Test Instrument by following the operating instructions provided with the instrument. Make TEST Transmissions from all the positions where you want to site the detectors and check the signal strength. If signal strength is weak, decide on a different position for the or install a repeater on the site. NB: In a majority of cases a repeater will not be necessary due to the exceptional transmission range from the detectors to the Masthead. The will achieve a better signal strength at the Masthead than the LGWT434 hand held walk test instrument therefore if the reading is marginal, then the will likely work in this position. Step 3 When all positions have been tested and approved the fitting of the detectors can take place. Programme the required Site code, Unit code and Sub net code. Plug the white battery connector on to the white two pin plug positioned on the left hand side of the board. Now fit the front lens housing to the rear battery housing making sure not to trap the battery wires. Fit the two M5 16 mm screws and tighten. Positioning The correct height for the is 2 to 2.5 metres above the ground. Careful consideration when positioning the detector will greatly reduce nuisance alarms. The detector requires a clear view of the area to be covered. Make sure that nothing can move or flutter in front of the detector and avoid facing reflective surfaces. The fixing of the detector must be solid and not sway. Avoid situations where the detector can over shoot the detection area. Fig 2 Banding or Jubilee clip holes One of the two socket fixing screws for securing to wall plate. Connecting the batteries Unscrew the two rear socket screws and remove the whole front of the detector to expose the rear battery compartment. If changing the batteries, fit two 1.5 volt Alkaline C cell s. Always use high power long life types. Observe polarity as shown. Fixing Bracket Anti Tamper spring actuator Positive Tie wraps Wall mounting screw holes Hide the banding screw joints inside the wall plate. Make sure they are in the centre. C cell 1.5 volt Fixing Undo the two socket screws from the wall plate and remove the black fixing bracket. For WALL MOUNTING use the four screws and wall plugs provided. For POST MOUNTING use banding or Jubilee clips. When it is secure, the wall plate may be hung back on the bracket and the two socket screws re-fitted. Positive Fig 3 C cell 1.5 volt Connect Flying Socket to detector circuit board Set the CODE and FUNCTION switches as described later and connect the Flying Socket to the circuit board. Re-fit the to the rear half. Insert the two screws and tighten. LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 14 LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 7

Codes & Functions explained There are three elements to the coding used on this system. SITE codes These separates one site from another. The site is the area covered by all the s on the system. It can be made very far reaching by deploying repeaters. The Masthead and all s as well as any other devises used on the system such as Repeaters, Walk Test Instruments and Pagers must all be set to the same site code. You can have 32 sites all within radio reception range that will not interact with one another if they each have a different Site Code. UNIT codes These codes identify each individual detector on the site. There are 64 unit codes which are the maximum number of s per site. More s can be fitted to a site but another system with a different site code must be installed to accommodate them. Angle Adjustment For left and right movement, slacken the socket screw under the pivot as shown using the 3 mm key provided. For up/down movement, slacken the two socket screws either side of the pivot as shown in Fig 8. Antenna connection Fit the antenna on the screw stud and tighten the dome nut to secure it. (Do not over tighten). If a sun shield is required, fit this first. Sun shield Fit the sun shield to improve performance in strong sun light. The sun shield also helps in keeping snow of the lens. To fit the shield, place the tab over the screw stud and clip both sides of the shield down at the front. SUB NET codes (Only applicable if repeaters are used) These separate the site up into sections. All s and repeaters on the site are set to the same site code but will only communicate with a masthead or repeater which has the same sub net code. Distant s will need to rout through one or more repeaters. Those s must send the receiving sub net code that has been set on the nearest repeater. That repeater then sends a transmitting sub net code to the next repeater or masthead. Repeaters have a separate receiving and a transmitting sub net code. Pagers and Walk Test Instruments will respond to all unit & sub net codes and will receive from anywhere over the site. Up to seven repeaters and one masthead may be deployed on any one site. Some examples are shown on the following page. The first is the most common scenario where all s communicate directly with the masthead without repeaters. Figures 4,5&6 are typical examples of Sub Net usage Fig 8 Optional Sun shield Locate antenna vertically on the screw stud and tighten dome nut. Up/Down adjustment screw Up/Down adjustment screw Wall Plate Left/Right adjustment screw LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 8 LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 13

Pulse count Counts the number of pulses caused when a person walks across the detector s field of view. The greater the number, the more the person has to move to cause an alarm. Pulse count 1 is very sensitive while pulse count 4 is quite insensitive. Experiment with the setting to optimise the results so that persons are detected in good time but not so sensitive that the detector may be prone to false alarm from incidental movement from trees, shrubs, loose materials etc. Sensitivity The normal setting is 0. Low sensitivity is sometimes needed to reduce the detection distance. Higher sensitivity increases distance but also increases the risk of false activation from environmental conditions. AND / OR The Genesis 2 detector uses a Quad in line pyro sensor which acts like two separate sensors side by side. The AND / OR mode can select whether both sensors must detect movement together or whether only one or the other is required. AND gating is the best form of filtering out nuisance alarms from loose materials, foliage and reflections. OR gating is more sensitive and may be selected when fast moving objects are to be detected. Power saving Busy sites such as school playgrounds, car park entrances etc can cause an unnecessarily large number of alarm transmissions. Although these alarms may be ignored during the day time it is still wasteful of battery power and therefore in these circumstances it is recommended that the Power saving mode be selected. There are four types of power saving which may be selected to suit. Fig 4. Fig 4 shows s communicating directly with the Masthead. All Sub Nets are 1. MAST SYSTEM CONTROLLER REP 1 Masthead KEY SUBNET 1 REP KEY SUBNET 1 SUBNET 2 1 Masthead & 2 Repeaters REP MAST SYSTEM CONTROLLER 1 Masthead & 1 Repeater Fig 5. Fig s 5 & 6 show examples where one or more repeaters are used and how the Sub Net Codes separate the system. 1. An alarm can only be sent after 3 minutes of inactivity 2. An alarm can only be sent after 10 minutes of inactivity 3. An alarm can only be sent after 30 minutes of inactivity 4. The same as 3 but with an accumulative timer which can extend the 30 minutes if the site remains very busy. In addition the sleep timer does not initiate after the first alarm but instead after a build up of activity. KEY SUBNET 1 SUBNET 2 SUBNET 3 MAST SYSTEM CONTROLLER Fig 6. LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 12 LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 9

PROGRAMMING This new improved Genesis 1 model now has an LED display and push buttons which makes changing settings much easier and enables extra features. Button functions SELECT M MEMORISE UP DOWN M TAMPER MODE OPTIONS SETTINGS SI SITE 1 to 32 SU SUB NET 1 to 8 Un UNIT NUMBER 1 to 64 PL PULSE COUNTING 1 to 4 SE SENSITIVITY -5..0..+5-5 Lowest, 0 Normal, +5 Highest An AND/OR GATING 0 = OR 1 = AND PS POWER SAVING 0-OFF, 1 to 4 ON (Four modes) Power On When the power is turned on, the display shows momentarily. How to set standard functions Step 1. Enter the settings mode press M until the display shows Step 2. Scroll through mode the options with the select button When the desired mode is reached, wait a moment and then the display will flash the setting. EG: followed by = pulse count 1. To change a setting, select the mode and wait for the setting to flash. Scroll up or down to the desired number. Step 3. Press and hold the M button to store the new number. The display shows followed by Now let go of the button and the new setting is stored. EXAMPLE: M To change more than one setting at a time, follow steps 1 and 2 and after changing the setting press to select the next mode. Press the M button when all changes have been made. NB: The display will automatically turn off after 10 minutes if M is not pressed. LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 10 M WIRELESS TRANSMISSION CODE SETTINGS Site code These codes are used to separate one site from another. There are 32 codes to choose from and any number can be used as long as it is different from other nearby sites that are using Genesis products. The LGWT434 Walk Test Instrument can be used to search for nearby sites and display the site codes used so that you can avoid them. Sub net A division of the site code and usually only used where repeaters are required. See LGMT434 operating instructions for more information. Unit code Each detector must have an individual unit number. Set the first detector as UNIT1 and the second as UNIT2 etc. Do not duplicate numbers or leave gaps. FUNCTIONS Pulse count Counts the number of pulses caused when a person walks across the detector s field of view. The greater the number, the more the person has to move to cause an alarm. Pulse count 1 is very sensitive while pulse count 4 is quite insensitive. Experiment with the setting to optimise the results so that persons are detected in good time but not so sensitive that the detector may be prone to false alarm from incidental movement from trees, shrubs, loose materials etc. LGWP-15/40/VC/HC Wireless Detector Installation Handbook Page 11