Wireless Fire & Security Solutions. Fire Product Showcase

Similar documents
Wireless Fire & Security Solutions. Fire Product Showcase

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Product Guide MAN7030-2

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Maintenance Guide EMS Security Group Ltd. All rights reserved. MK154 Iss5 18/11/15 AJM

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

5000 INSTALLATION GUIDE

ZITON RADIO LOOP MODULE

IGD.CO.UK

Solution F2. Fire Alarm Control Panels one step ahead.

Wireless Fire & Security Solutions. Product Catalogue. Prices effective from 01/07/2017 Prices exclude VAT

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Intelligent addressable fire alarm control panel

Consultant Specification AGILE Wireless Fire Detection System

Sita200plus. 200detectors. Single loop analogue addressable System

Addressable and Conventional Fire Protection

Automatisk Branddetekterings- og Alarm-system Automatic Fire Detection and Alarm System

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Wireless Fire Solutions

ZXSe Range Data Sheet

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

EFBW series - BiWire Ultra control panel

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Fire detection and alarm

XP95/Series 90 Test Set

FIRElux Emergency Lighting

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Analogue addressable devices

Touch Screen 1 loop Addressable Fire Alarm Panel

Apollo Accreditation. Need further information? Visit

The EN54 Part 2 & 4 Fire System

Intelligent Addressable Fire Alarm System

Eurofyre Limited range of ProFyre C24 Control and Indicating Equipment (refer to attached appendix for details and conditions) Certification Manager

arm wire free solutions nurse call personal security fire alarms

DS7400Xi Addressable Control/ Communicator

Addressable Carbon Monoxide Detection, Monitoring & Ventilation System

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

Fire control panels FC726 FC726-XA

FC700A Fire detection control unit

CODESEC FIRE ALARM SYSTEMS. security technologies

Evolution Product Range

Scope. Warning sounders except specific requirements. Intercom Systems for Emergency Purposes. Sound Systems for Emergency Purposes

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

FC723 Fire control panel

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

CONTROL PANELS. Tech Data Sheet D01688GB1 10/2012 Fire Detection. Control Panels of the FX 3NET (ALC) Fire Detection System

Cerberus FIT conventional system

A Guide To BS Understanding the selection, spacing and siting of detectors

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

The Kentec driver connects to the Kentec Syncro range of fire detection panels. Available for Commander and ObSys.

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE

FC724 Fire control panel

APPLICATION DATA SHEET

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant

FC724 Fire control panel

APPLICATION DATA SHEET

FC722 Fire control panel

XP95 Sounder VAD Base

1) This manual covers 4400, 5400 and 6400 fire alarm systems. The differences are described in the appropriate sections.

Solution F1. Fire Control Panels the new generation

Basic Fire Alarm SystemTraining. Arman Alnasar

Engineer Paging. Staff Paging. Deaf Alert.

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Desigo Fire Safety Marine Fire and Detection Equipment Models FH-2071-UM, BP-62 and USCG-HPLATE

Different types of Fire Alarm System

Automatic Fire Alarm System

The technological shield of fire safety

Fire control panels FC360

APPLICATION DATA SHEET

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Addressable Fire Alarm Control Panel

FC2020 Fire control panel

Addressable Loop Powered Visual Alarm Devices

The complete conventional fire warning system

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

Intelligent Security & Fire Ltd

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Advanced FireAlarm Panel 1-4Loop

Sinteso TM product catalog.

An introduction to... Sigma

Fire Detection - Addressable

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Intelligent Single Loop Fire Alarm Control Panel

Synova TM product catalog.

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

TrueAlarm Fire Alarm Controls

Reliably Advanced Extinguishing Control

P R O D U C T D ATA S H E E T

AlertWave. visiplex. From a Public Address System to an Emergency Communication System... The AlertWave system advantages:

For Complete Fire and Gas Solutions

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

FC722 Fire control panel

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Transcription:

Wireless Fire & Security Solutions Fire Product Showcase

2

Contents Contents 3 Product Overview 4-5 Control Panels 6-8 Control Panel Accessories / Power Supplies 9-10 Wireless Infrastructure 11-12 Aerials 13 Wireless Detectors 14-15 Audio Visual Alarm Devices 16-18 Manual Call Points 19 I/O Units 20 Survey Equipment 21 FireCell Hybrid (Wired Apollo Devices) 22-28 Batteries 29-30 Pagers 31 Spares 32-33 EMS Support 34-35 3

Wireless Fire & Security Solutions EMS has a number of wireless / hybrid solutions available that can be utilised to meet almost any application. All are fully EN54-25 third party approved products meeting all current standards and carry the CE Mark confirming compliance with all applicable EU directives. EMS wireless solutions are based on 868MHz wireless technology. This product showcase provides specific details with relevant information and data. 31 31 RCC RCC 31 RCC RADIO HUB RCC CONTROL PANEL CONTROL PANEL WIRELESS NETWORKING 31 RADIO LOOP MODULE 31 Based on EMS technology FireCell is fully scalable from standalone smaller single loop systems through to multi building networks. 4

FireCell uses a Hub and Cluster infrastructure and can be either a 100% wireless system or a combination of wired and wireless loops depending on the application. Using a fire resistant cable, the Wireless Hub connects to the loop input/output of the CIE. Each Hub supports up to four wireless loops. Using this option a system can be configured with both wired and wireless loops and a four loop CIE could, for example, have a single wireless loop with three hard wired loops. A FireCell system can be single loop, two loop or four loop and support up to 126 devices per loop and 504 devices per panel (four loops). These can be wired or wireless devices depending on the configuration. Each loop must be dedicated as wired or wireless although Radio Loop Modules (RLMs) can be added to the wired loop for localised wireless devices. Larger systems, with up to eight panels, can be wirelessly networked using the EMS Radio Network Communicator (RNC) and support up to 4,032 devices. CONTROL PANEL The Fusion Radio Loop Module supports any combination of wireless devices up to a total of 31 loop addresses. The RLM itself will take up one additional loop address. RADIO LOOP MODULE Each Fusion RLM is wired on to and powered directly from the loop. All wireless devices, including sounders, have their own power supplies (batteries) and do not need to be included in the loop loading calculations. 31 Each hard wired loop can support a maximum of five RLMs. All EMS supplied hardwired devices are for XP95 protocol integration via XPERT 7 bases. 5

Control Panels FC-LA80161 M2 Syncro AS Lite Analogue Addressable Fire Panel 1 Loop 16 Zone Surface mounted with enable key. Not expandable. Requires 2x batteries - select from pages 29 and 30. FC-A80161 M2 Syncro AS Analogue Addressable Fire Panel 1 Loop 16 Zone Surface mounted with enable key. Optional expansion cards available. Requires 2x batteries - select from pages 29 and 30. FC-A80162 M2 Syncro AS Analogue Addressable Fire Panel 2 Loop 16 Zone Surface mounted with enable key. Optional expansion cards available. Requires 2x batteries - select from pages 29 and 30. FC-ENSA63482 03 Syncro Analogue Addressable Fire Panel 2 Loop 48 Zone Surface mounted with enable key. Optional expansion cards available. Requires 2x batteries - select from pages 29 and 30. 6

FC-ENSA63484 03 Syncro Analogue Addressable Fire Panel 4 Loop 48 Zone Surface mounted with enable key. Optional expansion cards available. Requires 2x batteries - select from pages 29 and 30. FC-ENSA63964 03 Syncro Analogue Addressable Fire Panel 4 Loop 96 Zone Surface mounted with enable key. Optional expansion cards available. Requires 2x batteries - select from pages 29 and 30. FC-K691000 M1 Focus+ Network LCD Repeater Panel Surface mounted with PSU and enable key. Includes network card. Requires 230Vac power. 24Vdc variant also available. Requires 2x batteries - select from pages 29 and 30. FC-K67000 M1 Syncro View Local LCD Repeater Surface mounted with enable key. Simple two-wire connection to control panel. Replicates all Syncro control panel controls. 24Vdc powered, from control panel or local supply. 230Vac variant also available. 7

Control Panel Packages FCX-700-440 Syncro AS Lite Analogue Addressable Fire Panel 1 Loop 16 Zone and FCX-500-004-V3 Radio Hub Surface mounted with enable key. Not expandable. Requires 2x 12V 9Ah batteries. FCX-700-441 Syncro AS Analogue Addressable Fire Panel 1 Loop 16 Zone and FCX-500-004-V3 Radio Hub Surface mounted with enable key. Optional expansion cards available. Requires 2x 12V 9Ah batteries. FCX-750-001 Fusion Lite package includes: 1x FC-LA80161 M2, 1x FCX-532-001, 4x FCX-170-001 Wireless Detector Bases & 4x Detectors. Detectors to be advised at point of order. Choose 4 Detectors from: FCX-175-001 FCX-176-001 FCX-177-001 See Page 14 for more detector information. Requires 2x 12V 9Ah batteries. 8

Control Panel Accessories / Power Supplies FC-K555 Network interface card for wired and wireless networks One required per control panel. FCX-438-001 FireCell Radio Network Communicator For use with FC-K555. One required per control panel. FC-K545 Syncro I/O - 4 way Conventional Detection Zone Module FC-K546 Syncro I/O - 6 Way Sounder Extender Board 9

FC-K16250 M2 I/O Box and Chassis fitted Complete with 2.5A PSU fitted. Accomodates 2x backup batteries (max 9Ah). Other variants available upon request. Requires 2x batteries - select from pages 29 and 30. FC-M2FCLGT Flush Mounting Collar For use with Syncro AS 1 and 2 loop panels. FC-KD25250 03 Dual Output 24Vdc 2.5A PSU 500 (w) x 355 (h) x 117 (d) mm enclosure. Maximum 2x 12Ah batteries. Requires 2x batteries - select from pages 29 and 30. FC-KD25400 15 Dual Output 24Vdc 5.25A PSU 500 (w) x 460 (h) x 190 (d) mm enclosure. Maximum 2x 26Ah batteries. Requires 2x batteries - select from pages 29 and 30. 10

Wireless Infrastructure FCX-500-004-V3 FireCell Radio Hub (Four loop) Includes latest V3 software. FCX-500-444-V3 FireCell Radio Hub (Four loop) with Remote Aerial Facility Remote aerials not included. Includes latest V3 software. FC-555-001-V3 FireCell Wireless Radio Cluster Communicator Includes PSU. Includes latest V3 software. Requires FC-006-004 6V 4Ah standby battery. FC-555-331-V3 FireCell Wireless Radio Cluster Communicator with Remote Aerial Facility Remote aerials not included. Includes PSU and latest V3 software. Requires FC-006-004 6V 4Ah standby battery. 11

FC-555-024-V3 FireCell Wireless Radio Cluster Communicator 24Vdc Includes latest V3 software. Requires 24Vdc power. FCX-532-001 FireCell Fusion Radio Loop Module Loop powered. Up to five per loop using FireCell panel, subject to cable specification. EK-10-0001 Wireless Zone Monitor Kit (Universal) Includes: 1x EC-13-0000 1x EC-41-0200 1x EC-63-0001 12

Aerials (optional) FC-868-A03 FireCell standard vertically mounted dipole aerial (For use with RCCs and Hubs with Remote Aerial Facility) Includes three metres of URM76 coaxial cable and mounting bracket. For internal use only. FC-868-D03 FireCell weather-resistant vertically mounted dipole aerial (For use with RCCs and Hubs with Remote Aerial Facility) Includes three metres of URM76 coaxial cable and mounting bracket. 7329 UHF 3dB high gain aerial for use with Radio Network Communicators For use with FC-438-001. Includes five metres of RG58 cable and mounting bracket. 13

Wireless Detectors FCX-175-001 FireCell Class A1R Heat Detector Only For use with FCX-170-001, FCX-191-000 and FCX-191-200 bases. FCX-176-001 FireCell Class CS Heat Detector Only For use with FCX-170-001, FCX-191-000 and FCX-191-200 bases. FCX-177-001 FireCell Optical Smoke Detector Only For use with FCX-170-001, FCX-191-000 and FCX-191-200 bases. 14

FCX-170-001 FireCell Wireless Detector Base Only Includes 6x AA batteries. Select Detectors from page 14. FCX-191-000 FireCell Wireless Combined Sounder / Detector Base Only Includes 3x AA & 3x C batteries. Select Detectors from page 14. FCX-191-200 FireCell Wireless Combined Sounder with Visual Indicator and Detector Base Only Available with clear Visual Indicator upon request. Includes 3x AA & 3x C batteries. Select Detectors from page 14. 15

Audio Visual Alarm Devices FC-171-002 FireCell Red Wireless Sounder Base Only For use with all audio/visual devices. Includes 3x AA and 3x C batteries. FC-171-001 FireCell White Wireless Sounder Base Only For use with all audio/visual devices. Includes 3x AA and 3x C batteries. FC-172-002 FireCell Red Sounder Only For use with FC-171-001 and FC-171-002 bases. FC-172-001 FireCell White Sounder Only For use with FC-171-001 and FC-171-002 bases. 16

FC-323-WA2 FireCell Red Wall Beacon Only Category W-3.1-11.3 For use with FC-171-001 and FC-171-002 bases. Available in white upon request. FC-323-CA2 FireCell Red Ceiling Beacon Only Category C-3-15 For use with FC-171-001 and FC-171-002 bases. Available in white upon request. FC-315-WA2 FireCell Red Wall Sounder / Beacon Only Category W-3.1-11.3 For use with FC-171-001 and FC-171-002 bases. Available in white upon request. FC-315-CA2 FireCell Red Ceiling Sounder / Beacon Only Category C-3-15 For use with FC-171-001 and FC-171-002 bases. Available in white upon request. 17

FC-178-002 FireCell Red Visual Indicator Only For use with FC-171-001 and FC-171-002 bases. Other colours available upon request. FC-173-002 FireCell Red Sounder Visual Indicator Only For use with FC-171-001 and FC-171-002 bases. Other colours available upon request. FCX-178-001 Wireless Remote Indicator Module Includes wireless base. Includes 6x AA batteries. FC-179-002 FireCell Sounder Weather Resistant Kit Certified to IP55. For use with FC-171-001 and FC-171-002 wireless bases. 18

Manual Call Points FC-200-002 FireCell Red Wireless Manual Call Point Includes wireless base. Includes 6x AA batteries. FC-FGCOVER Protective Cover for Call Points For use with FC-200-002. (Wireless Call Point not included). 19

I/O Units FC-610-001 FireCell Wireless Dual Input and Output Module Includes 6x AA batteries. FC-620-001 FireCell Auxillary Relay Module Includes 2x 230Vac 2A switching relays. For use with FC-610-001. 20

Survey Equipment FC-868-SE2 FireCell Wireless Survey Kit Includes surveyor unit, device and extension rods. Comes in convenient carry case. Training packages available upon request. 21

FireCell Hybrid (Wired Apollo Devices) 45681-210APO XP95 Mounting Base Only Includes XPERT card. 45681-284APO Isolating Base Only Includes XPERT card. 45681-277APO Integrated Base Sounder with Isolator Only Includes XPERT card. 45681-393APO Integrated Base Sounder and Visual Indicator with Isolator Only Includes XPERT card. 22

45681-705APO Cat O. XP95 Sounder VAD Base with Isolator Only Includes XPERT card. 45681-709APO Cat O. XP95 VAD Base with Isolator Only Includes XPERT card. 45681-700APO Cat O. Discovery Sounder VAD Base with Isolator Only Includes XPERT card. 45681-211APO Isolator Base Only For use with 55000-720 isolator. 23

55000-720APO Isolator Only Requires 45681-211APO base. 55000-600APO XP95 Optical Smoke Detector Only Base not included. Select from pages 22 and 23. 55000-885APO XP95 Multisensor Detector Only Base not included. Select from pages 22 and 23. 55000-400APO XP95 Heat Detector Only Base not included. Select from pages 22 and 23. 24

58000-600APO Discovery Optical Smoke Detector Only Base not included. Select from pages 22 and 23. 58000-700APO Discovery Multisensor Detector Only Base not included. Select from pages 22 and 23. 58000-400APO Discovery Heat Detector Only Base not included. Select from pages 22 and 23. 55100-908APO XP95 Manual Call Point with Isolator Red (Surface). 25

58100-908APO Discovery Manual Call Point with Isolator Red (Surface). 58200-950APO Discovery Weatherproof Manual Call Point Red (Surface). Does not include isolator. 55000-740APO Red Cat C. XP95 Loop Powered VAD 15M Only Also available in white. Base not included. Select from pages 22 and 23. 55000-741APO Red Cat W. XP95 Loop Powered VAD 6M Only Also available in white. Base not included. Select from pages 22 and 23. 26

55000-742APO Red Cat C. XP95 Loop Powered VAD 8M Only Also available in white. Base not included. Select from pages 22 and 23. 55000-001APO Discovery Intelligent Open-Area Multi-tone Sounder Red. 55000-298APO Weatherproof Multi-tone Sounder and Visual Indicator Red (Surface). 55000-847APO XP95 Single Input/Output with Isolator 27

55000-875APO XP95 Mains Switching Single Input/Output with Isolator 28

Batteries (for use with FireCell products) FC-809-000 AA 1.5V Alkaline Panasonic Powerline Battery for use with FireCell wireless devices FC-810-000 C 1.5V Alkaline Panasonic Powerline Battery for use with FireCell wireless devices FC-006-004 6V 4Ah Sealed Lead Acid Battery for Radio Cluster Communicator One per unit. FC-012-007 12V 7Ah Sealed Lead Acid Battery 29

FC-012-008 12V 0.8Ah Sealed Lead Acid Battery For use with FC-400-SCO paging kit. FC-012-009 12V 9Ah Sealed Lead Acid Battery FC-012-012 12V 12Ah Sealed Lead Acid Battery FC-012-015 12V 15Ah Sealed Lead Acid Battery 30

Pagers FC-400-EU1 Client Pager Receiver 96 character display with tone and vibration. Includes 1x AAA battery. FC-400-EUC Protective Cover For use with FC-400-EU1. FC-400-SCO Pager Transmitter Includes 12V PSU and aerial. Serial interface and FC-000-KEN lead for FireCell control panel connection. Requires FC-012-008 12V 0.8Ah standby battery. 31

Spares FC-S005 Spare Control Panel Key Set For use with FireCell Syncro and Syncro AS panels. Includes 801, 901, FH001 and KT3001 keys. FC-B2869 Thermal Printer Paper Roll FC-60-1000 6Vdc PSU For use with FireCell RCC. FCX-500-004 FireCell Radio Hub (Four loop) For use with legacy systems, with V2 software. 32

FCX-500-444 FireCell Radio Hub (Four loop) with Remote Aerial Facility Remote aerials not included. For use with legacy systems, with V2 software. FC-555-001 FireCell Wireless Radio Cluster Communicator Includes PSU. Requires FC-006-004 6V 4Ah battery. For use with legacy systems, with V2 software. FC-555-331 FireCell Wireless Radio Cluster Communicator with Remote Aerial Facility Remote aerials not included. Includes PSU. Requires FC-006-004 6V 4Ah battery. For use with legacy systems, with V2 software. FC-555-024 FireCell Wireless Radio Cluster Communicator 24Vdc Requires 24Vdc power. For use with legacy systems, with V2 software. 33

EMS Support FC-000-HUB FireCell Radio Hub Programming Lead FC-000-KEN FireCell Control Panel Programming Lead FC-000-PRG FireCell System Text and Configuration Programming FC-RIT FireCell Radio Communication (Integrity) Network Testing and Inspection Contact us for details on FirePoint 5000 testing & inspection. 34

FC-TRA-001 FireCell Training Course (price per delegate) 35

Wireless Fire & Security Solutions EMS Security Group Ltd Technology House Sea Street, Herne Bay Kent, UK, CT6 8JZ t: +44 (0) 1227 369570 f: +44 (0) 1227 369679 www.emsgroup.co.uk