Introduction to Flow Switch

Similar documents
Introduction to Level Switch Solutions

Switch-Pro. AU13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller

Thermo Flo With Compact Junction Box AT17, AT18, AG17 & AG18 Series Manual

INTRODUCTION / TABLE OF CONTENTS

INTRODUCTION / TABLE OF CONTENTS

Thermo-Flo Flow Switches FT10 and GT10 Series Owner s Manual

Centro-Matic Automated Lubrication Systems System Controls

Plug-in Base, Long Range Sensor E3B2

Oxygen (O2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

INTRODUCTION / TABLE OF CONTENTS

Two-Channel Gas Controller

Technical Specification VFD

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

MBCE-110/230UV Flame Sensor Module

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

DataPoint Continuous Relay Controller LC52 Series Manual

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Sitron s CF Line of Flow Switch Monitors

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

Cabinet Cooler Systems

VIBRATION TRANSMITTER MODEL 140T INSTALLATION The mounting orientation can be in any position. This position should be in an area for the best vibrati

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

MBCE-110/230FR Flame Sensor Module

Process Alarm Module RTA 421

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Acessories BROCHURE JUNHO 2013

Continuous Relay Controller LC52 Series Owner s Manual

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

TDS Conductivity Probe In-Line conductivity measurement

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Water Leak Detector. Installation and Troubleshooting. Overview

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Power Supply Display Module PSDM. Installation and Operation Manual

Dräger PointGard 2100 Detection of toxic gases and vapours

T500 Elite - Hotbus Plant Wide Monitoring System for Bucket Elevators & Conveyors

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

High Pressure Conductivity Monitor

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Solid State Relays SOLITRON MIDI Current Sensing Type RJCS, RJCSR

PolyGard 2-channel Gas Controller MGC-03

Duct and Rough Service Carbon Monoxide Sensor

INSTRUCTION & SERVICE MANUAL

Tubular Industrial Process

The Clark-Reliance Corporation TWIP System Installation and Maintenance Instructions - Form E112 -

Pump-Up Controller MODEL 4062

S1L Series: Metal Bottom

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

! WARNING. Before using product, read and understand instructions.

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

Level gauges Series LS Level indicator, switch and transmitter for liquids

Dräger REGARD -1 Control System

Applications and Features

Inductive Conductivity

WFDE Series Waterflow Detector

RF Admittance Technology FACTS

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Pump-Down Controller MODEL 4052

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch

Installation and Operating Instructions

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

Operating Instructions. For. Alarm Control Module. Model SSR 500

Tubular Industrial Process

SUPPLEMENTAL INSTRUCTION SHEET POL S2 POINT OBSTRUCTION LIGHT SINGLE WITH ALARM

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

CM800 Emergency Call System

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

Ultrasonic Switches. Features & Benefits

Ramsey Motion Monitoring Systems

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

! WARNING. Before using product, read and understand instructions.

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

5.0. Photoelectric Sensors. Technical Reference. Introduction

Ultrasonic Point Level Switches

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

Combustible Gas Detection and Control System

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Transcription:

Introduction to TM Solutions Flow Detection, Switching & Control Flow switches detect a change in state from flow or no-flow within pipe or ducting. Correspondingly, the sensor inverts a contact to signal an alarm or control a pump or valve. Flowline general purpose liquid and gas flow switches are offered in sensor and package configurations. Sensors are available in PP-Ryton or PVDF bodies with a 1A SPST relay and adjustable flow switch set point. The sensors are also available in packages with compact relay controllers for pump control or junction boxes for wiring termination. Select the appropriate flow switch type based upon your application media, supply, control and installation requirements. es Relay Controllers Sensors FT10 / GT10 Compact Packages AX1X Controller Page 77 AX1X Junction Box Page 78 FT10 Type LC30 Sensor AX1X Sensor + Controller Class LC8X Page 80 Page 79 GT10 Remote Page 81 AX1X LC30 LC8X Sensor + Junction Compact Controller Remote Controller GP Media Liquid Gas Liquid, Gas Function Low-Flow Alarm Low-Flow Shut Off Low-Flow Alarm Relay(s) (1) SPST (1) SPDT (1) SPST (1) SPDT (1-2) SPDT Optional Optional 120-240 VAC 12-36 VDC Strobe Alarm Supply 12-36 VDC Temperature Pressure Material 76 120-240 VAC 140 F (60 C) 150 PSI (10 bar) PP-Ryton, PVDF --PP www.flowline.com Low-Flow Shut Off Call Us 562.598.3015

Liquid & Gas Offered in liquid and gas sensor types, the general purpose flow switch provides reliable low or no-flow detection of relatively clean, non-coating media with one 1A relay output. Liquid examples include water and acetic acid. Available in Polypropylene-Ryton and PVDF, the short flow sensor is used in pipe or ducting from 1/2 to 1 1/2, and the long flow sensor is used in 2 and up. The flow switch set point may be adjusted from 0.04 to 3 fps in liquids, or 1 to 90 fps in gases as a low-flow alarm. The flow sensor is best applied in applications with relatively constant temperature. Set point range: Repeatability: Response time: Set point adjust.: LED indication: Supply voltage: Consumption: Contact type: Contact rating: Contact output: Process temp.: Ambient temp.: Pressure: Rugged Polypropylene-Ryton or PVDF sensor for corrosive liquids and gases FT10-1305 Sensor rating: Wetted material: Cable jack. mat.: Adjustable set point with LED for flow or no-flow status indication FT10-1405 60VA relay selectable NO or NC via power supply wiring polarity Pulse-point fitting for metering pump applications &DEOH P 137 5S 5(/$< 5HG %ODFN :KLWH 12 1& *UHHQ &20 6KOG &DEOH PP PP PP 137 * P T10 media F Liquid G Gas Sensor material (1) 1 PP / Ryton 5 PVDF Sensor length (2) 3 Short 4 Long Process mount (3) 0 NPT (US) 2 G / Rp (Metric) Liquid FT10 Series www.flowline.com 137 5S 5 PP FT50-5000 137 5S 5(/$< 5HG %ODFN :KLWH 12 1& *UHHQ &20 6KOG PP Solid state sensor is not damaged by over-ranging flow velocities Cable type: Cable length: Process mount: Mount. gasket: Classification: Compliance: PP PP PP 1) To special order a 25' (7.6m) or 50' (15.2 m) flow sensor cable, place the cable length at the end of the part number (ie: FT10-1305-25'). For PP, add $20 for 25' (7.6m) or $40 for 50' (15.2m) to the price. For PFA, add $75 for 25' (7.6m) or $150 for 50' (15.2m) to the price. 2) Order the short flow sensor for use with pipe sizes from 3/4"-1 1/2" (D25-D50) and the long sensor for 2" and higher (D63 up). 3) The metric sensor is offered with straight G threads on the sensing side and conical Rp threads on the cable side of the wrench flat. Email UsFax: 562.431.8507 level.solution@flowline.com FT10: 0.04 to 3 fps (0.012 to 0.91 mps) GT10: 1 to 90 fps (0.3 to 27 mps) ± 0.5% of set point 1-10 seconds Potentiometer Flow status 14-36 VDC 70 ma maximum (1) SPST relay 60 VA, 1A maximum Selectable NO / NC F: 32 to 140 C: 0 to 60 F: -40 to 140 150 psi (10 bar) @ 25º C, derated @ 1.667 psi (0.113 bar) per ºC above 25º C NEMA 4X () -1XX5: PP-Ryton -5XX5: PVDF -1XX5: Polypropylene -5XX5: PFA 4-conductor, shielded 10 (3m) 3/4 NPT (3/4 G) Viton General purpose CE 77 77

with Compact Flow Controller TM Offered in liquid and gas sensor types, the general purpose flow switch package provides reliable no or low-flow detection of relatively clean noncoating media with a 16A compact flow controller for pump or process protection. Liquid examples includes water and sulfuric acid. The optional flash alarm brings attention to low-flow alarm conditions. Available in Polypropylene-Ryton and PVDF, the short flow sensor is used in pipe or ducting from 1/2 to 1 1/2, and the long flow sensor is used in 2 and up. The flow switch set point may be adjusted from 0.04 to 3 fps in liquids, or 1 to 90 fps in gases for low-flow control. The flow sensor is best applied in applications with relatively constant temperature. Rugged Polypropylene-Ryton or PVDF sensor for corrosive liquids and gases Fail-safe relay control of pumps or valves with 0-60 second delay Polypropylene enclosure rated NEMA 4X with swivel base for conduit alignment Optional strobe brings immediate attention to flow alarm conditions AT12-1620 Shown with FT50-1000 fitting Set point range: AT1X: 0.04 to 3 fps (0.012 to 0.91 mps) AG1X: 1 to 90 fps (0.3 to 27 mps) Repeatability: ± 0.5% of set point Response time: 1-10 seconds Set point adjust.: Potentiometer LED indication: Sensor, power & relay Supply voltage: 120 / 240 VAC, 50-60 Hz. Consumption: 0.25A maximum Strobe type: -X61X: Xenon tube -X62X: N/A Strobe flash: -X61X: 1 per second -X62X: N/A Contact type: (1) SPDT relay Contact rating: 250 VAC @ 16A Contact output: Selectable NO / NC Contact delay: 0-60 seconds Process temp.: F: 32 to 140 C: 0 to 60 Ambient temp.: F: -40 to 140 Pressure: 150 psi (10 bar) @ 25º C, derated @ 1.667 psi (0.113 bar) per ºC above 25º C Enclosure rating: NEMA 4X () Enclosure mat.: -X61X: PP, UL94VO & PC -X62X: PP, UL94VO Conduit entrance: 1/2 NPT Wetted material: -16XX: PP-Ryton -36XX: PVDF Process mount: 3/4 NPT (3/4 G) Mount. gasket: Viton Classification: General purpose Compliance: CE Invert switch changes relay state from NO to NC without rewiring Solid state sensor is not damaged by over-ranging flow velocities media T Liquid G Gas Sensor length (1) 2 Short 4 Long Sensor material 1 PP / Ryton 3 PVDF Configuration 1 Controller with Strobe Alert 2 Controller only Process mount 0 NPT (US) 4 G (Metric) A 1-6 1) Select the short sensor for use with pipe sizes from 3/4"-1 1/2" (D25-D50) and the long sensor for 2" and higher (D63 up). 78 www.flowline.com Call Us 562.598.3015

with Compact Junction Box Offered in liquid and gas sensor types, the general purpose flow switch package provides reliable no or low-flow detection of relatively clean non-coating media with a 1A relay output and compact junction box for wiring termination. Liquid examples includes water and acetic acid. Available in PP-Ryton and PVDF, the short flow sensor is used in pipe or ducting from 1/2 to 1 1/2, and the long flow sensor is used in 2 and up. The flow switch set point may be adjusted from 0.04 to 3 fps in liquids, or 1 to 90 fps in gases as a low-flow alarm. The flow sensor is best applied in applications with relatively constant temperature. Rugged Polypropylene-Ryton or PVDF sensor for corrosive liquids and gases Adjustable set point with LED for flow or no-flow status indication Polypropylene enclosure rated NEMA 4X with swivel base and terminal strip AT17-1630 Set point range: AT1X: 0.04 to 3 fps (0.012 to 0.91 mps) AG1X: 1 to 90 fps (0.3 to 27 mps) Repeatability: ±0.5% of set point Response time: 1-10 seconds Set point adjust.: Potentiometer LED indication: Flow status Supply voltage: 14-36 VDC Consumption: 70 ma maximum Contact type: (1) SPST relay Contact rating: 60 VA, 1A maximum Contact output: Selectable NO / NC Process temp.: F: 32 to 140 C: 0 to 60 Ambient temp.: F: -40 to 140 Pressure: 150 psi (10 bar) @ 25º C, derated @ 1.667 psi (0.113 bar) per ºC above 25º C Enclosure rating: NEMA 4X () Enclosure mat.: PP, UL94VO Terminal strip: 6-pole, socket Conduit entrance: 1/2 NPT Wetted material: -163X: PP-Ryton -363X: PVDF Process mount: 3/4 NPT (3/4 G) Mount gasket: Viton Classification: General purpose Compliance: CE 60VA relay selectable NO or NC via power supply wiring polarity Solid state sensor is not damaged by over-ranging flow velocities AT17-3630 media T Liquid G Gas Sensor length (1) 7 Short 8 Long Sensor material 1 PP 3 PVDF Process mount 0 NPT (US) 4 G (Metric) A 1-63 Junction Box 1) Select the short sensor for use with pipe sizes from 3/4"-1 1/2" (D25-D50) and the long sensor for 2" and higher (D63 up). www.flowline.com Email Us Fax: 562.431.8507 level.solution@flowline.com 79

Compact Flow TM Controller The general purpose flow controller accepts one flow sensor input, and provides one 16A relay for low-flow pump or process protection. The optional flash alarm brings attention to low-flow alarm conditions. Package this flow controller with our liquid or gas flow switch sensors. Supply voltage: Consumption: Sensor input: Sensor supply: LED indication: Strobe type: Strobe flash: Contact type: Contact rating: Contact output: Contact delay: Ambient temp.: LC30-1002 Fail-safe relay control of pumps or valves with 0-60 second delay Enclosure rating: Enclosure mat.: Optional strobe brings immediate attention to flow alarm conditions Conduit entrance: Enclosure mount: Classification: Compliance: Approvals: Polypropylene enclosure rated NEMA 4X with swivel base for conduit alignment 120 / 240 VAC, 50-60 Hz. 0.25A maximum (1) flow switch 24 VDC @ 50 ma Sensor, power & relay -10X1: N/A -10X2: Xenon tube -10X1: N/A -10X2: (1) per second (1) SPDT relay 250 VAC @ 16A Selectable NO / NC 0-60 seconds F: -40 to 140 NEMA 4X () 10X1: PP, UL94VO 10X2: PP, UL94VO & PC 1/2 NPT 3/4 NPT (3/4 Rp) General purpose CE CSA, LR 79326 Tech Tip Easy setup with LED indicators for sensor, power and relay status The AC powered relay controller has a 16A relay, adjustable time delay, LED indicators and NO or NC invert switch. The rugged NEMA 4X enclosure is made of UL approved fire retardant polypropylene with a swivel base for easy conduit alignment. Invert switch changes relay state from NO to NC without rewiring Compatible with Flowline liquid and gas flow switch sensors (71mm) Controller 2.8" LC30-1001 1.0" Compact Relay Controller LC30 Series (25mm) 3.2" (81mm) 4.7" (119mm) L C 3 0-10 Enclosure mount 0 NPT (US) 5 Rp (Metric) Configuration (1) 1 Controller only 2 Controller with Strobe Alert 80 www.flowline.com 1) For a liquid tight cable connection, order the LM90-1001 connector. Call Us 562.598.3015

Remote Flow Controller LC80-1001 Supply voltage: 120 / 240 VAC, 50-60 Hz. Consumption: 5 watts maximum Sensor inputs: LC80: (1) flow switch LC82: (2) flow swiitches Sensor supply: 24 VDC @ 50 ma LED indication: Sensor, power & relay Contact type: LC80: (1) SPDT relay LC82: (2) SPDT relays Contact rating: 250 VAC @ 10A Contact output: Selectable NO / NC Contact latch: LC80: N/A LC82: Selectable ON / OFF Contact delay: 0-60 seconds Ambient temp: F: -40 to 140 Enclosure type: 35mm DIN rail Enclosure mat.: PP, UL94VO Classification: General purpose Compliance: CE Approvals: CSA, LR 79326 The general purpose flow controller is offered in two configurations for low-flow pump and process protection. The LC80 accepts one flow sensor input and provides one 10A relay for low flow control. The LC82 accepts two flow sensor inputs and provides two 10A relays for dual low flow control. Package this flow controller with our liquid or gas flow switch sensors. For field mount installation, add a single or dual controller NEMA box. Fail-safe relay control of pumps or valves with 0-60 second delay Easy setup with LED indicators for sensor, power and relay status 35 mm DIN rail mount polypropylene enclosure with removable terminal strips Invert switch changes relay state from NO to NC without rewiring Top View 3.9" (98mm) P OWER INVERT DELAY INVERT DELAY - + - + RELAY 1 RELAY 2 STANDARD CONTROLLER LATCH INPUT 1 INPUT 2A ON OFF INPUT 2B Side View 1.8" (44mm) 2.7" (68mm) es Package the controller with our liquid or gas flow switch sensors. See pages 77 and 79 for more details. LM94-1001 3.1" (79mm) 3.6" (92mm) 35mm DIN Rail Contact(s) / input(s) (1) (2) 0 1 Relay / 1 sensor 2 2 Relays / 2 sensors LC8-1001 1) The flow controller is compatible with liquid and gas flow sensors. 2) For field mount installation in a NEMA 4X polycarbonate enclosure, order the LM94-1001 (single controller box) or the LM95-1001 (two controller box). www.flowline.com Email Us Fax: 562.431.8507 level.solution@flowline.com 81