1592P01. for liquids in piping DN

Similar documents
1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

FSW300 Series Flow Switch

Frost Protection Thermostat

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Frost Units for air temperature monitoring

SIKA VK300 OR VK325 SERIES FLOW SWITCH Operating Manual

Electronic timeswitch

Multi line separator module

Room thermostat with 24-hour time switch and large LCD

Room Temperature Controllers

Output module (230 V)

Mimic display driver, LED ribbon cable

Input module, input/output module

Room Temperature Controller

Room thermostats with LCD RDD100..

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Room thermostat with Auto Timer, independent DHW

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

Indoor Air Quality Controller

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Temperature Sensor TRG Original Installation Instructions English

Input module, input/output modules

Flush-mounted room thermostat

Room thermostat with independent DHW control

OH720, OP720, HI720, HI722

Wireless room thermostat with LCD

Semi flush-mount room thermostats

DM1131 / DM1133 / DM1134 Manual call points

Installation, operating and servicing instructions

RVL479. Heating Controller. for use with a partner unit

Interbases. Sinteso FDSB221, FDSB228, FDSB229

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

QAW70. Room Unit. Building Technologies. for use with heating controllers

! WARNING. Before using product, read and understand instructions.

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

Wall-mounted room thermostat with LCD

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

FDOOT221, FDO221, FDT221

KOBOLD PSR/PS FLOW SWITCH

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Flush-mounted room thermostats

! WARNING. Before using product, read and understand instructions.

Room Temperature Sensors

! WARNING. Before using product, read and understand instructions.

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation

Call stations and extensions

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

Room thermostat with Auto Timer, Option External Input

Instructions for the fan motor control system, SILVER C

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Duct Temperature Sensors

Use. For 2-pipe fan coils

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

Conductivity Electrode LRG Original Installation Instructions English

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

District heating controller

FDOOT241-9, FDOOT241-A, FDO241, FDT241

smart mounting Induction Heater IH 070/090 Bedienungsanleitung Instructions for use Mode d emploi Manuale d istruzioni Manual de instrucciones

M7100 Pressure Transducer

Flow Switches. Series VHS, VKS, VH

GESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode

Level Electrode NRG NRG Original Installation Instructions English

FDOOT241-A9-Ex Multisensor fire detector

District heating controller

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

Installation & Operating Instructions

ASA linear smoke detector

OEM Sensors for HVAC manufacturers Heat recovery Chiller

Platen Heater Pad Replacement

WARNING This is a Warning statement that is related to the use of this heater. These statements warn of actions that may result in physical injury.

NRG NRG NRG NRG

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

OEM Sensors for HVAC manufacturers Pool water

Waste water ejection unit

LC3000 Level Controller Installation and Maintenance Instructions

IMPORTANT SAFETY INSTRUCTIONS:

NON-SUBMERSIBLE WATER PUMP

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

VERSAFLOW VORTEX Supplementary instructions

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

TRG 5-6x. GESTRA Steam Systems. Installation Instructions

FDCW241 Radio gateway Mounting

Hakki Pilke Raven spare parts manual

Instructions for the fan motor control system with integrated wiring terminals SILVER C

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

Transcription:

1 594 1592P01 Flow switch for liquids in piping DN 20 200. QVE1901 Contact load / switching capacity: max. AC 230 V, 1 A, 26 VA max. DC 48 V, 1 A, 20 W Nominal pressure PN25 Manual setting of contact type (NO / NC) Housing IP 65 / safety class II Maintenance free Mode of operation Flow monitor of liquid medium in HVAC plants in hydraulic systems, in particular, refrigeration, heat pump and heating plants, e.g. for evaporators, boilers, heat exchangers, etc. Ordering When ordering, please provide the name and product number: Flow switch QVE1901 CM1N1594en 2018-07-30 Building Technologies

Mechanical design Switching value table for water at 20 C The device records the flow of monitored medium via a paddle system (1), which has a permanent magnet (2) attached at its upper end. A reed contact (3) is positioned outside the flow above this magnet. A second magnet (4) with opposite polarity is used to create a reset force. The paddle system moves once it comes into contact with the monitored flow. The magnet (2) changes its position to the reed contact (3). The contact opens/closes depending on the contact type. As soon as the flow is interrupted, the paddle returns to its original position and the reed contact opens/closes depending on the contact type. (See "Adjusting the switching unit" on page 5) 1 V 1594G01 1 V 1 V 1 V 1594G01 2 2 2 2 DN Qmax (m3/h) (m 3 /h) Factory setting (m 3 /h) 20 4 0.9 1.1 0.9 1.1 25 5 1.1 1.3 1.1 1.3 32 8 1.6 1.9 1.6 1.9 40 10 1.8 2.1 1.8 2.1 50 14 2.4 2.7 2.4 2.7 80 30 4.7 5.1 4.7 5.1 100 40 5.8 6.4 5.9 6.4 150 100 14.2 15.5 14.2 15.5 200 180 29.0 30.0 29.0 30.0 Engineering notes On site, a T-junction 1/2" thread per EN DIN 10241 required (steel fittings with threads) and EN DIN 10242 (threaded fitting from malleable casting) required All dimensions and data provided in the table of switching values are based on water at 20 C, the use of T-junctions and horizontal piping Before and after the mounting location of the flow switch, a smoothing path of at least 10 times or 5 times respectively the nominal pipe diameter required 2/8

Flow switch installation Mechanical installation General installation instructions When choosing the installation site, ensure that the specified limit values (see "Technical Data" are not exceeded. Select suitable measures to prevent the medium from freezing. If the flow switch is to be used in ambient temperatures of <4 C, do not carry out any operation beforehand using pure water. Residual water in the flow switch can result in frost damage. First, clean the pipe system where the flow switch is installed and remove any magnetic particles, e.g. wielding residue. The smoothing section in front of and behind the flow switch must be at least 10 times or 5 times respectively. The nominal installation position of the flow switch is "upright standing position" in horizontal pipework. The switches should only be installed in a vertical position; deviation max. of 45. Please make sure that there are no external magnetic fields in the immediate vicinity of the flow switch, since these can impair device operation. There is an arrow on the flow switch. Ensure during installation that the arrow is parallel with the pipe shaft and is facing in the flow direction. DN20 200 The brass connecting nut G¾ has a tightening torque of 25...30 Nm. Nut size 27 external thread G½A, 14mm Welding nipple with female thread G½ 3/8

Installation notes Observe all local regulations from the electrical utilities or waterworks as applicable Allow for an extra loop of the connecting cable to ensure the switching value can be adjusted Electrical connections Warning Danger of death due to electrical voltage! Work on electrical installations may only be carried out by qualified electricians or by instructed persons working under the guidance and supervision of a qualified electrician, in accordance with the electrical regulations. Always de-energize the system before connecting the wires of the mains cable. CAUTION: Ensure that the maximum electrical contact load specified on the type plate is never exceeded; otherwise the reed contact integrated in the switching unit will be damaged. Inductive loads impair switching capacity. Please ask the manufacturer for information on protective circuits. Elbow plug connector EN 175301-803-A Fig. 1 Fig. 2 Fig. 3 Fig. 4 Loosen the central screw (pos. 6) M3x35 and disconnect the junction box EN 175301-803-A (pos. 2) from the connector (pos. 1, Fig. 1). Use a screwdriver or similar tool to press out the core (pos. 8) of the junction box (Fig. 2). Loosen the screw connection PG 9 (pos. 5, Fig. 3). Feed the connecting cable into the junction box via the screw connection (pos. 5), the clamping ring (pos. 10) and the rubber insert (pos. 9) and subsequently connect the wires as displayed in the connection diagram (see Fig. 4). not occupied 4/8 Press the core (pos. 8) until it locks into position in the junction box (pos. 2). Tighten the cable gland PG 9 (pos. 5). Place the junction box (pos. 2) on the connector (pos. 1) and retighten the central screw (pos. 6).

To guarantee the protection class IP 65 per EN 60529, the applied connecting cable has to have a sheathing diameter of between 4.5 and 7 mm. Furthermore, ensure that all the connector seals (pos. 3, 4 and 9) have been correctly inserted. Adjust switching unit Standard contact The switching unit of the control switch enables 2 contact types: 1. Make contact (normally open): RED arrow on the switching unit 2. Break contact (normally closed): WHITE arrow on the switching unit The following table explains the two contact types: Contact type Setting Flow rate Electric contact increasing closing Make contact (NO) RED arrow decreasing opening Break contact (NC) WHITE or BLUE arrow increasing decreasing opening closing Unless otherwise agreed to with the customer, the switching unit is factory set to make contact, i.e. opens if the set switching point is exceeded. In order to adjust the switching unit, open the cover of the switching head Subsequently loosen the locking screw (2.5 hexagon socket screw) and position the switching unit until the red or white arrow are visible at the entry of the switching contact guide for a desired make contact or break contact respectively. You can use the arrow length to make fine adjustments to the switching point: Adjust to the arrowhead means: Switching point is at a lower flow rate. Adjust to the arrow end: Switching point is at a higher flow rate. Carefully retighten the locking screw. We recommend you to use lacquer/thread locker to secure the locking screw of the switching unit after carrying out individual adjustments. Close the cover until it locks into place. 5/8

The switching unit does not need to be adjusted when the customer requests a factory set switching point. Maintenance and repair Disposal The flow switch is maintenance-free and cannot be repaired by the user. In the unlikely event of a defect, the device has to be returned to the manufacturer for repair. The device is considered an electronic device for disposal in accordance with the European Guidelines and may not be disposed of as domestic garbage. Dispose of the device via the channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Technical data Functional data Degree of protection Environmental conditions Field of use Suitable media All liquids (not suitable for ammonia) Piping diameter DN 20 200 Type of switch Reed contact Max. contact rating AC 230 V, 1 A / DC 48 V, 1 A Max. switching capacity AC 26 VA / DC 20 W External supply line protection (EU) Fuse slow max. 10 A or Circuit breaker max. 13 A Characteristic B, C, D according to or Power source with current limitation of max. 10 A Switching point adjustment manual, supplied with minimum switch-off value Tolerance of switching point ranges in the table ±15 % Setting range See switching value table Medium temp. (medium cannot freeze) -20 110 C Nominal pressure PN 25 Protection class III according to EN 60730-1 Housing IP65 according to EN 60529 General environmental conditions Operation and storage -20 80 C Ambient humidity <95 % r.h. 6/8

Standards, directives, and approvals Environmental compatibility Product standard EN 60204-1 Safety of machinery - Electrical equipment of machines EU Conformity (CE) CM1T1594xx *) EAC Conformity Eurasia Conformity The product environmental declaration CM1E1594 *) contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal). Materials / Color Weight Housing Screw-in body G½" excl. packaging Polyamide, black Brass 0.31 kg *) The documents can be downloaded from http://siemens.com/bt/download. 7/8

Dimensions Cutting the paddle DN L 3 (mm) 20 40 ±1 25 46 ±1 32 51 ±1 40 61 ±1 50 71 ±1 80 91 ±1 DN 40 61 ±1 DN 32 51 ±1 DN 25 46 ±1 DN 20 40 ±1 1594Z10 9 15 20 30 40 50 60 DN 50 71 ±1 DN 80 91 ±1 DN 100.. DN200 111 ±1 100 111 ±1 150 111 ±1 70 200 111 ±1 80 Flow switch 74 120 46 12 38 92 ±1 12 G ½ A 9 L3 15 20 30 40 50 60 70 80 1594M02 Dimensions in mm Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Theilerstrasse 1a CH-6300 Zug Switzerland Tel. +41 58-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd 2007 Delivery and technical specifications subject to change 8/8