for relative humidity and temperature with calibration certificates

Similar documents
Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Room Temperature Sensors

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Duct Temperature Sensors

for relative humidity and temperature

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

for relative humidity and temperature

Duct Air Quality Sensors

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Room Air Quality Sensors

Room air quality sensors

QPM21 Series Duct CO 2 and Air Quality Sensors

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

PRELIMINARY EDITION

Room Temperature Controller

Duct Temperature Sensors

Room Temperature Controller

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

Differential pressure sensors

Self-learning Room Temperature Controller

Room Temperature Controller with LCD

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

Semi flush-mount room thermostat

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

Room Temperature Sensor

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Immersion Temperature Controller

Preliminary Release. Room Temperature

The fan is switched to the selected speed via control output Q1, Q2 or Q3.

QAW70. Room Unit. Building Technologies. for use with heating controllers

Self-learning Room Temperature Controller

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

Room Temperature Sensors

Room Temperature Controllers

No. Icon Name Function

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Room thermostat with Auto Timer, Option External Input

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

Flame detector. Building Technologies Division Infrastructure & Cities Sector

Flame detector. The QRA4.U is for use with the following types of burner control:

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

Flame Safeguards LFE10. Building Technologies HVAC Products

RVP310. Heating Controller. Building Technologies HVAC Products

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Room thermostat with Auto Timer, Option External Input

Flame detector. The QRA4.U is for use with the following types of burner control:

Ceiling Mount Temperature Sensor

Frost Protection Thermostat

Heating Controller. Building Technologies HVAC Products. Synco 700

Self-learning Room Temperature Controller

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

Room thermostats with LCD for wall mounting

Room Temperature Controller

Use. Functions. Key function. Other functions

C Note! LGI16... Burner Controls. Building Technologies

Heating Element. Building Technologies HVAC Products

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

Room Unit. Building Technologies SYNERGYR

RVL481. Heating Controller. including d.h.w. heating

UV Flame Supervision System

Constant climate chambers

BC3250. Blowdown Controller

Wireless room thermostat with LCD

Self-learning Room Temperature Controller

Motion detector UP 255, UP 256, UP 257, UP 258 5WG AB 5WG AB 5WG HB

Infrared Flame Detectors

RVL479. Heating Controller. for use with a partner unit

TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a

Flame Safeguards LFE10. Building Technologies HVAC Products

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Self-learning Room Temperature Controller

Flush-mounted room thermostat

REA 105 Arc Protection Module. Operator s Manual

RVL480. Heating Controller

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

REA22 Room Temperature Controller

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

HBTS Temperature Sensor For temperature measurement in refrigeration systems

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Flush-mount room sensor KNX S-Mode / KNX LTE- Mode / KNX PL-Link

QRA10... QRA53... QRA55...

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Constant climate chambers

WE INCREASE UPTIME AND EFFICIENCY IN THE REFRIGERATION INDUSTRY

Hygro/hygrothermal transducers (hygrometric)

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Flush-mounted room thermostats

Transcription:

1 859 1859P01 1859P02 QFA4160 AQF4150 Symaro Room Sensor for relative humidity and temperature with calibration certificates QFA4160 Operating voltage AC 24 V or DC 13.5...3 Signal output DC 0...10 V for relative humidity and temperature Very high measuring accuracy across the entire measuring range Capacitive humidity measurement Recalibration service Use The QFA4160 sensor is used in ventilation and air conditioning plants requiring: Very high accuracy and reliability for measuring relative humidity and temperature Regular recalibration and readjustment of the sensors Examples: Storage and production facilities in the paper, textiles, pharmaceutical, chemical, electronics industries, etc. Laboratories Hospitals Computer centers Greenhouses CE1N1859en 26.07.2004 Siemens Building Technologies HVAC Products

Ordering and delivery When ordering, please give name and type reference: Room sensor QFA4160 The circular connector with its screwed plug is delivered uninstalled. Equipment combinations The QFA4160 is for use with all types of systems and devices that can acquire and handle the sensor s DC 0...10 V output signal. Technical design Relative humidity Temperature The sensor acquires relative humidity via its capacitive sensing element whose capacitance varies as a function of the relative humidity of the ambient air. An electronic circuit converts the sensor s signal to a continuous DC 0...10 V signal, corresponding to a relative humidity of 0...100 %. The sensor acquires the temperature via its sensing element whose electrical resistance varies according to the temperature of the ambient air. This variation is converted to an active DC 0...10 V output signal, corresponding to a temperature range of 0...50 C, 35...+35 C, or 0...70 C. The measuring range can be selected. Mechanical design The room sensor consists of housing, printed circuit board, connection terminals, measuring rod and circular connector. The housing consists of 2 parts: Base and removable cover (screwed). A rubber seal is installed between housing and cover in order to satisfy the requirements of IP 65 degree of protection. The measuring circuit and the setting element are accommodated on the printed circuit board inside the cover, the connection terminals on the base. Housing and measuring rod are screwed together. The sensing elements are located at the end of the measuring rod, protected by a screw-on filter cap. Cable entry is made via the circular connector, which consists of coupling piece with M16 thread and connector with screwed plug. The coupling piece is secured to the housing and internally wired. The sensor is designed for wall mounting. Setting element Range 1 2 3 Measuring range 123 Test function active U1 U2 10 V 0 V 10 V 0 V 1859Z03 The setting element is located inside the cover. It consists of 6 pins and a shorting plug. It is used for selecting the required temperature measuring range and for activating the test function. 2/6

The different shorting plug positions have the following meaning: For the active temperature measuring range: Shorting plug in the left position (R1) = 35...+35 C, Shorting plug in the mid position (R2) = 0...50 C (factory setting) Shorting plug in the right position (R3) = 0...70 C For the active test function: Shorting plug in the horizontal position: The values available at the signal output are those given in the table Test function active Behavior in the event of fault Calibration certificates If the temperature sensor is faulty, the voltage at signal output U2 is 0 V and the humidity signal at signal output U1 increases to 10 V If the humidity sensor is faulty, the voltage at signal output U1 is 10 V after 60 seconds; the temperature signal remains active The sensor and its exchangeable AQF4150 measuring tip are numbered, registered and calibrated prior to delivery. The associated calibration certificates are supplied with the sensor. Accessories Name Measuring tip (exchangeable) Filter cap (for replacement) Type reference AQF4150 AQF3101 Engineering notes Use a safety extra low-voltage (SELV) transformer with separate windings designed for 100 % duty. All safety regulations valid at the location of the plant must be observed when sizing and protecting the transformer. When sizing the transformer, the sensor s power consumption must be taken into consideration. For the electrical connection of the sensor, refer to the Data Sheets of the devices with which the sensor is used. The maximum permissible cable lengths must be observed. Cable routing and cable selection For cable routing, it should always be considered that electrical interference is the greater, the longer the cables run parallel and the smaller the distance between them. Use shielded cables if necessary. Twisted pairs of cables are required for the secondary supply lines and the signal lines. Mounting notes Mounting location Caution! Mounting position Mounting Instructions Inside wall (not on outside wall!) of the room to be air conditioned; not in recesses, shelves, behind curtains, above or close to heat sources; not on walls behind which a chimney is located. The sensor must not be exposed to direct solar radiation. Install the sensor in the occupied space about 1.5 m above the floor and at least 50 cm from the next wall. The seal between housing and cover must not be removed, or else degree of protection IP 65 will be no longer ensured. The sensing elements inside the measuring rod are sensitive to shock and impact. Avoid any such impact on mounting. The QFA4160 must not be mounted with the measuring rod pointing upward. Mounting Instructions are printed on the inner side of the package. 3/6

Commissioning notes Prior to switching on power, check wiring. On the sensor, select the required temperature measuring range. Recalibration service SBT HVAC Products provides a recalibration service for used sensors. Recalibration should be performed at 12-month intervals under "normal" conditions, i.e. within the comfort range for humidity and temperature, and at air contamination levels that are not above average. Services provided The recalibration service includes the following: Delivery and invoicing of the new AQF4150 measuring tip complete with calibration certificate Delivery of a calibration certificate for the (old) measuring tip returned to SBT HVAC Products, enabling the customer to assess the time of usage of the measuring tip Technical data Power supply Cable lengths for the measuring signal U1, U2 Functional data Humidity sensor" Functional data "Temperature sensor" Degree of protection Electrical connections Operating voltage Frequency Power consumption Max. perm. cable lengths Copper cable 0.6 mm dia. Copper cable 1 mm 2 Copper cable 1.5 mm 2 Measuring range AC 24 V ±20 % or DC 13.5...3 50/60 Hz 1 VA 50 m 150 m 300 m Measuring accuracy at 23 C 0...100 % r.h. ±2 % Temperature dependency Time constant 0...100 % r.h. 0.05 % r.h./ C approx. 20 s in moving air Output signal, linear (terminal U1) DC 0...10 V 0...100 % r.h., max. ±1 ma Measuring range Sensing element Measuring accuracy in the range of 15...35 C 35...+70 C Time constant Output signal, linear (terminal U2) 0...50 C (R2 = factory setting), 35...+35 C (R1), 0...70 C (R3) Pt 1000 class B ±0.6 K ±0.8 K approx. 20 s in moving air Housing IP 65 to IEC 529 Safety class III to EN 60 730 Connector with screwed plug Screw terminals for Cable entry DC 0...10 V 0...50 C / 35...+35 C / 0...70 C ±1 ma max. Lumberg RSC 4/9 0.75 mm 2 max. 4 8 mm dia. 4/6

Environmental conditions Operation to Climatic conditions Temperature (housing with electronics) Humidity Mechanical conditions Transport to Climatic condition Temperature Humidity Mechanical conditions IEC 721-3-3 class 4K2 40...+70 C 0...100 % r.h. (with condensation) class 3M2 IEC 721-3-2 class 2K3 25...+70 C <95 % r.h. class 2M2 Materials and colors Base polycarbonate, RAL 7001 (silver-grey) Standards Weight Housing cover Scale Filter cap Circular connector Connector with screwed plug Contact carrier and body Knurled nut and contact Coupling piece Contact carrier Casing and contact Sensor (entirely) Packaging polycarbonate, RAL 7035 (light-grey) polycarbonate, RAL 7001 (silver-grey) polycarbonate, RAL 7001 (silver-grey) Lumberg RSC 4/9 PA, black CuZn, nickel-plated Lumberg RKFM 4/0.5 M TPU CuZn, nickel-plated silicon-free corrugated cardboard Product safety Automatic electrical controls for household and similar use EN 60 730-1 Electromagnetic compatibility Emissions Immunity conformity to conformity to Australian EMC framework Radio Interference Emission Standard Incl. packaging EN 61 000-6-1 EN 61 000-6-3 EMC directive 89/336/EEC Radio Communication Act 1992 AS/NZS 3548 0.196 kg Connection terminals G (R1 = 35...+35 C / R2 = 0...50 C / (r.h.) R3 = 0...70 C) G0 U1 U2 1859G01 G0 (3) U1 (2) 3 2 4 1 G (4) U2 (1) 1859G02 Front view: Connector fitted, body removed G, G0 Operating voltage AC 24 V (SELV) or DC 13,5...3 U1 Signal output DC 0...10 V for relative humidity 0...100 % U2 Signal output DC 0...10 V for temperature 0...50 C (R2 = factory setting) or 35...+35 C (R1) or 0...70 C (R3) 5/6

Dimensions 80 39 62,8 60 84 57 1859M01 41 Drilling plan AQF4150 ø 15 10,5 14,5 Dimensions in mm 6/6 2004 Siemens Building Technologies AG Subject to alteration