Room Temperature Sensor

Similar documents
Room Temperature Sensors

Room Air Quality Sensors

Room thermostat with Auto Timer, Option External Input

Room Temperature Controller

Room Temperature Sensors

Central apartment unit

Semi flush-mount room thermostat

Central apartment unit with QAX913 consumption data acquisition

Room Temperature Controllers

Room air quality sensors

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Room Temperature Controller with LCD

Room Temperature Controller

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Use. For 2-pipe fan coils

Room thermostat with Auto Timer, Option External Input

Room thermostat with Auto Timer, Option External Input

RVL480. Heating Controller

Room Temperature Controller

Room thermostats with LCD RDD100..

RVL481. Heating Controller. including d.h.w. heating

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Self-learning Room Temperature Controller

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Room thermostat with independent DHW control

Digital Room Thermostat for Heating Applications with 7-Day Time Program

Wireless room thermostat with LCD

Room thermostats with LCD for wall mounting

for relative humidity and temperature with calibration certificates

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

Room thermostat with 24-hour time switch and large LCD

Duct Air Quality Sensors

PRELIMINARY EDITION

Flush-mounted room thermostat

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Flush-mount room sensor KNX S-Mode / KNX LTE- Mode / KNX PL-Link

Preliminary Release. Room Temperature

Duct Temperature Sensors

Flush-mounted room thermostats

Room Units and Sensors for Use in Heating Plants. Siemens Building Technologies HVAC Products SIGMAGYR. Type summary

Wall-mounted room thermostat with LCD

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

The fan is switched to the selected speed via control output Q1, Q2 or Q3.

RVL479. Heating Controller. for use with a partner unit

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Room thermostat with Auto Timer, Option External Input

Flame detector. The QRA4.U is for use with the following types of burner control:

Room thermostat with Auto Timer, independent DHW

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Semi flush-mount room thermostats

RAB21 RAB21.1. For two-pipe fan coils

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

Flame detector. Building Technologies Division Infrastructure & Cities Sector

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

QPM21 Series Duct CO 2 and Air Quality Sensors

REA22 Room Temperature Controller

Thermostatic Actuators

Self-learning Room Temperature Controller

Smart Thermostat RDS110

Climapro 2. Installation. wireless room thermostat without receiver.

Self-learning Room Temperature Controller

No. Icon Name Function

Reference Manual. Ionizer Module for XPR Analytical Balances

Immersion Temperature Controller

Indoor Air Quality Controller

QAW70. Room Unit. Building Technologies. for use with heating controllers

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Flame detector. The QRA4.U is for use with the following types of burner control:

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

Honeywell Temperature & Humidity Sensor with LCD

Semi flush-mount communicating room thermostats

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Frost Protection Thermostat

Self-learning Room Temperature Controller

FDM273 Radio manual call point Mounting

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Radio fire detection system

Weather Light Model: BAR210 / BAR210U / BAR210A USER MANUAL. EU-Declaration of Conformity...7 FCC Statement...7 Declaration of Conformity...

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

QFM21... Duct sensors. Symaro. for relative humidity and temperature

4-Day Weather Forecaster Station Model: WMH601

for relative humidity and temperature

Digital Thermometer with Ice Alert and Radio-Controlled Clock. Model: RMR382 USER MANUAL CONTENTS

Digital Thermometer with Ice Alert and Radio-Controlled Clock Model: RMR682

Product Announcement

Wake-up Vibration Alarm Model : VR101. User Manual

Radio fire warning panel SRC 3000

WIRELESS RAIN GAUGE WITH IN/OUT TEMPERATURE INSTRUCTION MANUAL

Wireless Humidity/ Temperature Monitor Remote Wireless Sensor

Digital Thermometer with Ice Alert and Clock

Synco living Operating Instructions. Edition 3.0 Controller series C CE1B2707en Building Technologies

Duct Temperature Sensors

62 MAX/62 MAX + Infrared Thermometer. Users Manual

Transcription:

2 701 Synco 900 Room Temperature Sensor QAA910 Wireless room temperature sensor for acquiring the room temperature RF communication based on KNX standard (868 MHz, unidirectional) Battery-powered by commercially available 1.5 V batteries Use For integration into the Siemens Synco 900 system For acquiring the room temperature in HVAC plant Especially suited for: Renovation projects (old buildings, museums, churches, historical buildings, etc.) Difficult wall-mounting situations (sanddstone, glass, etc.) Variable floor plans (different décors, other furniture) New construction projects CE1N2701en 11.07.06 Building Technologies HVAC Products

Equipment combinations The QAA910 room temperature sensor is designed for use with the Siemens Synco 900 system. For more detailed information about equipment combinations, refer to the Data Sheet of the central apartment unit (CE1N2707en). Ordering When ordering, please give quantity, product name and type reference. Scope of delivery Each QAA910 is supplied complete with a set of alkaline batteries, fixing material and Mounting Instructions. Product documentation The Operating and Commissioning Instructions for the QAA910 are contained in the product documentation of the central apartment unit. Functions Main function Binding Status query RF binding test Error and maintenance messages During operation, the QAA910 forwards the acquired room temperature to the central apartment unit, either periodically or in the case of changes. The binding is used by the QAA910 to sign on at the central apartment unit, thus integrating it into the RF system. The binding process is triggered via the multifunction button. It is indicated by the multifunction LED. The multifunction button can be used to query the batteries capacity. It is indicated by the multifunction LED. The multifunction button can be used to trigger a binding test. This test is made to check the radio link to the central apartment unit. The RF binding test is indicated by the multifunction LED. All error and maintenance messages are forwarded to the central apartment unit where they appear on the display. The following messages are delivered by the QAA910: Error messages Sensor error (failure of the room temperature sensor) Maintenance message Batteries discharged (battery life 3 months) 2/6

Operating and indicating elements Multifunction LED Multifunction button 2701Z01 Overview of functions of the indicating and operating elements of the QAA910: Multifunction LED Battery state Binding process Multifunction button Battery state query Binding RF binding test For more detailed information about the functions and operation of the QAA910, refer to the product documentation covering the central apartment unit. Notes on engineering and operation Mounting location The QAA910 must be mounted inside the house or building, on an inner wall about 1.5 m above the floor. To ensure that the QAA910 will acquire the room temperature as accurately as possible, the following conditions must be observed: The QAA910 must not be mounted on an outer wall, not in niches, bookshelves, and not behind doors or curtains Temperature acquisition must not be adversely affected by direct solar radiation, air drafts, or other heat or refrigeration sources The permissible environmental conditions must be observed The QAA910 must not be exposed to dripping water 3/6

For notes relating to engineering and mounting RF devices of the Siemens Synco 900 system, refer to Data Sheet CE1N2708en. The base of the QAA910 must be fitted on a flat wall Minimum clearance at the bottom should be 60 mm to ensure that the battery compartment can be easily opened 60 2701Z03 Mounting Commissioning Maintenance / battery change Note Mounting with the base. The QAA910 can be fitted to most commercially available recessed conduit boxes or directly on the wall. Mount the QAA910 first and then insert the batteries. Prior to commissioning, check to ensure that the QAA910 is correctly fitted to the wall and that the batteries are correctly inserted. The QAA910 is maintenance-free. The system indicates when batteries must be replaced. The batteries are located in the battery compartment. Batteries can be changed without removing the sensor from the wall and there is no need to use tools (reversed polarity protection). Disposal In terms of disposal, the QAA910 are classified as electronic scrap conforming to the European Directive 2002/96/EG (WEEE) and must not be disposed of as domestic waste. The relevant national legal regulations must be complied with. The sensor must be disposed of through the relevant channels. Local and currently valid legislation must be observed. Exhausted batteries must be disposed of in compliance with environmental regulations. Warranty Application-related technical data are only warranted in connection with the Siemens Synco 900 system. For equipment combinations, refer to the Data Sheet of the central apartment unit. When using the QAA910 together with third-party devices, correct functioning must be ensured by the user. In that case, Siemens will assume no responsibility for service and warranty. 4/6

Technical data Power supply Type of battery Battery life (capacity 2.5 Ah) 2 x alkaline batteries LR6 (AA) 1.5 V 3 years RF RF Range Protocol 868 MHz (unidirectional) typically m inside buildings KNX RF compatible Temperature sensor Standards Protection Sensing element NTC 10 kohm Measuring range 0 50 C Time constant 20 minutes -conformity to EEC directive - Immunity - Emissions Low-voltage directive - Electrical safety RTTE Radio & Telecom. Equipment - Radio communication Safety class III to EN 607 Housing IP40 1) to EN 60529 Degree of pollution 2 to EN 607 89/336/EC - EN 61000-6-1/2 - EN 61000-6-3/4 73/23/EC - EN 607-1 99/5/EEC - EN 0220-1, EN 0220-3, EN 1489-3 Dimensions Weight Housing material Housing color Unit complete with accessories refer to Dimensions 0.214 kg plastic ASA+PC white NCS S 0502-G Environmental conditions operation transport storage IEC 60721-3-3 EN 60721-3-2 EN 60721-3-1 Climatic conditions class 3K5 class 2K3 class 1K3 Temperature 0 +50 C -25 +70 C -20 +65 C Humidity 5 95 % r.h. <95 % r.h. 5 95 % r.h. (noncondensing) Mechanical conditions class 3M2 class 2M2 class 1M2 Elevation above sea level min. 700 hpa, corresponding to max. 3,000 m above sea level 1) Completely mounted 5/6

Dimensions Dimensions in mm 22 mm 1 mm 84 mm 42 42 28 28 2701M02 2701M01a TOP 76 mm 84 mm 28 28 12 4,2 6/6 2006 Siemens Switzerland Ltd Subject to change