FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

Similar documents
FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP400

FIRE RESISTANT CABLES FP300

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

LSOH Flexible Cables

STANDARDS INSTALLATION. Certificate No 077m

LSOH Wiring Cables. LSOH Conduit Wire (HO7Z-R) Low Voltage (450/750 V) Cable Approvals. Key Applications. Conductor. Insulation. Core Identification

FIRE PERFORMANCE CABLE

ENHANCED FIRE PERFORMANCE CABLE

High Performance LSZH Fire Resistant Cable

Introduction.

Selecting the AFUMEX range guarantees quality and offers the widest choice and the greatest safety.

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

BS /1000V XLPE Insulation LSZH Sheath Cables

Total Fire Solutions. Includes BS 8519 and the updated BS :

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

Fire Resistant Cables

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Multi-Core Fire Resistant Cable

fire resistant cables

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

Flame Retardant Overall Screened Instrumentation Cables (multicore)

FIRE RESISTANT CABLES

Photovoltaic Cables EN H1Z2Z2-K

LV FIRE RESISTANT CABLES

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

A guide. Part 1: Code of practice for system design, installation, commissioning and maintenance. by T.L. Journeaux

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

The Quality Connection. BETAflam Fire Resistant Safety Cables

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

THE TRUE FIRE SURVIVAL CABLE

Catalogue Telecommunication Cables INTRODUCCIÓN

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Telecommunication Cables

Caledonian Flame Retardant Coaxial Cables

OIL & GAS INDUSTRY OTHER INDUSTRIES

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Tratos Railway Cables

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

Catalogue Power Cables

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Guide to the Specification and Installation of Pyro Mi Wiring Cables

INTERNATIONAL STANDARD

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red


Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Requirements for Electrical Installations

PRODUCT CATALOGUE Norröna

Corporate Presentation. 14 June 2009

For Heavy Duty Commercial and Industrial Environments

Compact Module. Category 6A FTP Cabling System 1.1

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

KUTERLEX & KUTERLEX PLUS PLASTIC COATED COPPER TUBE

Caledonian Fire resistant Coaxial Cables

Cable technology for highest safety requirements

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Cablosam Tapes for Fire-Resistant Cables

Catalogue. Instrumentation & Control Cables

CATEGORY 6A FTP RJ45 SOLUTION

WORLDWIDE CABLE EXPERTS

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

SAS Security and Alarm Safety Cables

Low Voltage Catalogue_Final ai 11/8/09 11:37:27 AM BICC 1 BICC Final Brochure-NEW.indd 1 7/5/10 3:02 PM

Caledonian fire Resistant signal & Data cables

PRODUCT RANGE.

System Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

V3 Intelligent Damper Control and Monitoring System

Havells Fire Survival Cables

Traction Cable Radox 3 GKW

INTERNATIONAL STANDARD

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

3 o/c2 The symbol used to show that a BS 88 device has a motor circuit application is a gg b gm c l z d I 2.

Single core cables with reduced wall thickness

UNIKA Universal Cable Cable Specialist

The Quality Connection. BETAflam safety cables for highest demands

LINEAR HEAT DETECTION SENSOR CABLE ACCESSORIES

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Power Control Cable Iec

DNVGL-CP-0401 Edition February 2016

Transcription:

FIRE RESISTANT CABLES FP PLUS New Generation Now with enhanced Insudite TM insulation

ENHANCED FIRE RESISTANT CABLES FP PLUS BS7629-1:2008 FP PLUS > Certificate No 077g/02 The new generation of FP PLUS TM is a highly durable and dressable, easy to terminate and install fire resistant cable, using an enhanced variant of the unique Insudite TM damage resistant insulation system. It brings to the market for the first time an enhanced fire alarm cable with the unmatched combination of rigidity and ease of bending associated with the market leading FP200 Gold cable. New generation FP PLUS TM sets previously unobtainable levels in ease of installation for an enhanced cable whilst maintaining full compliance with all the necessary test requirements. Approved for fire detection and fire alarm critical signal paths to BS5839-1:2002+A2:2008 and voice alarm systems to BS5839-8:2008 in enhanced application areas and emergency lighting systems to BS5266-1:2005. APPROVALS > In addition to approvals to BS7629-1 and BS6387 Category CWZ, FP PLUS TM has received BASEC and LPCB approval to BS5839-1:2002 for enhanced applications. This includes approval to BS EN 50200 Class PH120 and the new integrated fire, shock and water test BS8434-2 for 120 minutes. All Prysmian FP PLUS TM cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB. DATA CAPABILITY INSTALLATION > > FP PLUS TM has excellent data/signal transmission characteristics making it ideal for voice alarm, addressable and networked systems. In accordance with the new BS5839-1 and BS5266-1 requirements, cables must be supported by a fixing that can withstand the same fire conditions as the cable. To meet this requirement the use of Prysmian AP LSOH coated metal P-clips or the new FP Firefix TM rapid fixing system is recommended. FP PLUS TM should be installed in accordance with BS7671/IEE Wiring Regulations and/or any other appropriate national regulations or codes. It is suitable for indoor and outdoor installation in suitably protected environments and particularly appropriate for surface wiring, direct burial in plaster, tray or other installations requiring a dressable product. CABLE CHARTERISTICS Temperature Range -20 to +70 C Bending Radius Fixed r=6d Mechanical Impact Medium Fire Performance BS EN 60332-1-2 BS EN 50266-2-4 Flexibility Rigid Halogen Free BS EN 50267-2-1 Low Smoke Emissions BS EN 61034-2 Fire Resistance BS 6387 Category CWZ BS EN 50200 PH120 BS 8434-2 120 min

FP PLUS FIRE RESISTANT CABLES 300/500V KEY APPLICATIONS > Fire detection and fire alarm systems for buildings > Voice alarm systems > Emergency lighting > Other essential service circuits CABLE DESCRIPTION CONDUCTOR Plain annealed copper solid circular conductor complying with BS EN 60228 class 1. INSULATION High performance damage resistant enhanced Insudite TM. British Standard Type EI5. CORE IDENTIFICATION HARMONISED CORE IDENTIFICATION: o o brown-blue o o o brown-black-grey o o o o blue-brown-black-grey SCREEN/CPC Laminated aluminium tape screen bonded to sheath and in contact with full size tinned annealed copper circuit protective conductor which provides automatic screen earthing. SHEATH Robust thermoplastic enhanced LSOH sheath; Colour - White or Red. Other colours to special order. For external exposure the use of a white sheath is recommended. Nominal cross sectional area mm 2 Conceptual Construction no./mm Mean overall diameter mm Approximate cable weight kg/km Maximum conductor resistance at 20 C ohms/km rating DC or single phase Enclosed rating DC or single phase Clipped direct Volt drop DC or single phase mv/a/m 1 LSOH fixing clips Recommended accessories Colour - White or Red 2 Nylon LSOH gland FP Firefix TM fixing clips Two core 1.5 1/1.38 9.2 115 12.1 16.5 19.5 29 AP9 251/GL2520 UFPNF04 2.5 1/1.78 11.5 176 7.4 23 27 18 AP11 252/GL2520 - Notes to table 1 Recommended clip spacing 300 mm horizontal and 400mm vertical. 2 Brass glands may be used as an alternative. Minimum recommended installation temperature 0 C. Installation methods for current rating in accordance with BS7671/IEE Wiring Regulations. The tabulated ratings are based upon a 30 C ambient temperature and 70 C operating temperature. For other ambient temperatures or where cables are grouped together, appropriate rating factors should be applied. Temperature ratings factor Ambient Temperature C 25 30 35 40 45 50 Rating factor 1.03 1.00 0.94 0.87 0.79 0.71 Rating Factors for Groupings Number of circuits 2 3 4 5 6 7 Rating factor 0.80 0.70 0.65 0.60 0.57 0.54

Enhanced Fire Resistant Cables Low Voltage (300/500 V) FP Plus TM BS7629-1:2008 Certificate no 077g Key Applications > Fire detection and fire alarm systems for buildings. FP PLUS TM is BASEC and LPCB approved in accordance with the requirements of BS5839-1:2002+A2:2008 Clause 26.2 for enhanced fire resisting cables. Conductor > Plain annealed copper solid conductor complying with BS EN 60228 class 1. Insulation > Cross-linked damage resistant insulation (Type EI5) over mineral ceramic (mica/glass) tape. Screen > Laminated copper tape screen bonded to sheath and in contact with full size tinned annealed copper circuit protective conductor which provides automatic screen earthing. Core Identification oo brown-blue ooo brown-black-grey oooo blue-brown-black-grey Sheath > Robust thermoplastic LSOH sheath Colour - White or Red. Other colours to special order For external exposure the use of a white sheath is recommended Temperature Range -20 to +70 C Bending Radius Fixed r=6d Mechanical Impact Medium Fire Performance BSEN60332-1-2 BSEN50266-2-4 Flexibility Rigid Halogen Free BSEN50267-2-1 Low Smoke Emissions BSEN61034-2 Fire Resistant BS6387 Category CWZ BSEN50200 PH120 BS8434-2 120 min Ref: FPPlus/02/09 Prysmian Cables & Systems Limited, Sales Office, Chickenhall Lane, Eastleigh, Hants, SO50 6YU, UK Commercial Enquiries, Tel +44 (0) 8457 678 345, Fax: +44 (0) 23 8029 5465

FP PLUS TM Fire Resistant Cable Cable Details Nominal cross sectional area mm² Conceptual construction no./mm Mean overall diameter mm Approximate cable weight kg/km Maximum conductor resistance at 20 C ohms/km rating DC or single phase Enclosed rating DC or single phase Clipped direct Volt drop DC or single phase mv/a/m Recommended Accessories LSOH fixing Nylon LSOH clips 1 gland 2 Two Core 1.0 1/1.13 8.5 110 18.1 13 15 44 AP8 251/GL2520 Three Core 1.0 1/1.13 9.0 125 18.1 13 15 44 AP9 251/GL2520 1.5 1/1.38 10.0 150 12.1 16.5 19.5 29 AP10 251/GL2520 Four Core 1.0 1/1.13 10.3 160 18.1 13 15 44 AP10 252/GL2520 1.5 1/1.38 11.0 190 12.1 16.5 19.5 29 AP11 252/GL2520 1 Recommended clip spacing 300mm horizontal and 400mm vertical 2 Brass glands may be used as an alternative Minimum recommended installation temperature 0 C Installation methods for current rating in accordance with BS7671/IEE Wiring Regulations The tabulated ratings are based upon a 30 C ambient temperature and 70 C operating temperature. For other ambient temperatures or where cables are grouped together, the appropriate rating factors should be applied. Temperature ratings factor Ambient Temperature C 25 30 35 40 45 50 Rating factor 1.03 1.00 0.94 0.87 0.79 0.71 Correction factors for groupings Number of circuits 2 3 4 5 6 7 Rating factor 0.80 0.70 0.65 0.60 0.57 0.54 Ref:FPPlus/02/09 Prysmian Cables & Systems Limited, Sales Office, Chickenhall Lane, Eastleigh, Hants, SO50 6YU, UK Commercial Enquiries, Tel +44 (0) 8457 678 345, Fax: +44 (0) 23 8029 5465

Enhanced Fire Resistant Cables Low Voltage (300/500 V) FP Plus Flex BS7629-1:2008 Certificate no 077h Key Applications > Fire detection and fire alarm systems for buildings. FP PLUS Flex is BASEC and LPCB approved in accordance with the requirements of BS5839-1:2002+A2:2008 Clause 26.2 for enhanced fire resisting cables. Ideal for installations where a more flexible cable is required. Conductor > Plain annealed copper solid (1.0-1.5mm²) or stranded (2.5-4.0mm²) conductor complying with BS EN 60228 class 1 or class 2. Insulation > Cross-linked damage resistant insulation (Type EI5) over mineral ceramic (mica/glass) tape. Screen > Helically applied laminated copper tape screen in contact with full size tinned annealed copper circuit protective conductor which provides automatic screen earthing. Core Identification oo brown-blue ooo brown-black-grey oooo blue-brown-black-grey Sheath > Robust thermoplastic LSOH sheath > Colour - White or Red > Other colours to special order > For external exposure the use of a white sheath is recommended Temperature Range -25 to +70 C Bending Radius Fixed r=6d Mechanical Impact Medium Fire Performance BSEN60332-1-2 BSEN50266-2-4 Flexibility Semi Flexible Halogen Free BSEN50267-2-1 Low Smoke Emissions BSEN61034-2 Fire Resistant BS6387 Category CWZ BSEN50200 PH120 BS8434-2 120 min Ref: FPPlusFlex/01/09 Prysmian Cables & Systems Limited, Sales Office, Chickenhall Lane, Eastleigh, Hants, SO50 6YU, UK Commercial Enquiries, Tel +44 (0) 8457 678 345, Fax: +44 (0) 23 8029 5465

FP PLUS FLEX Fire Resistant Cable Cable Details Nominal cross sectional area mm² Conceptual construction no./mm Mean overall diameter mm Approximate cable weight kg/km Maximum conductor resistance at 20 C ohms/km rating DC or single phase Enclosed rating DC or single phase Clipped direct Volt drop DC or single phase mv/a/m Recommended Accessories LSOH fixing Nylon LSOH clips 1 gland 2 Two Core 1.0 1/1.13 8.8 110 18.1 13 15 44 AP8 251/GL2520 1.5 1/1.38 9.4 130 12.1 16.5 19.5 29 AP9 251/GL2520 2.5 7/0.67 11.2 180 7.4 23 27 18 AP11 252/GL2520 4.0 7/0.85 12.6 240 4.6 30 36 11 AP12 252 Three Core 1.0 1/1.13 9.4 130 18.1 13 15 44 AP9 251/GL2520 1.5 1/1.38 10.0 155 12.1 16.5 19.5 29 AP10 252/GL2520 2.5 7/0.67 12.0 220 7.4 23 27 18 AP11 252 4.0 7/0.85 13.4 300 4.6 30 36 11 AP13 254 Four Core 1.0 1/1.13 10.4 160 18.1 13 15 44 AP10 252/GL2520 1.5 1/1.38 11.0 190 12.1 16.5 19.5 29 AP11 252/GL2520 2.5 7/0.67 13.3 280 7.4 23 27 18 AP13 254 4.0 7/0.85 15.0 390 4.6 30 36 11 AP15 254 1 Recommended clip spacing 300mm horizontal and 400mm vertical 2 Brass glands may be used as an alternative Minimum recommended installation temperature 0 C Installation methods for current rating in accordance with BS7671/IEE Wiring Regulations The tabulated ratings are based upon a 30 C ambient temperature and 70 C operating temperature. For other ambient temperatures or where cables are grouped together, the appropriate rating factors should be applied. Temperature ratings factor Ambient Temperature C 25 30 35 40 45 50 Rating factor 1.03 1.00 0.94 0.87 0.79 0.71 Correction factors for groupings Number of circuits 2 3 4 5 6 7 Rating factor 0.80 0.70 0.65 0.60 0.57 0.54 Ref:FPPlusFlex/01/09 Prysmian Cables & Systems Limited, Sales Office, Chickenhall Lane, Eastleigh, Hants, SO50 6YU, UK Commercial Enquiries, Tel +44 (0) 8457 678 345, Fax: +44 (0) 23 8029 5465

UK Sales enquiries Tel: 0845 767 8345 Fax: 023 8029 5465 Overseas Sales enquires Tel: +44 23 5029 5481 Fax: +44 23 8029 5465 UK Technical helpline Tel: 023 8029 5222 Fax: 023 8029 5111 tech.info@prysmian.com Prysmian Cables & Systems Limited Chickenhall Lane Eastleigh Hampshire S050 6YU United Kingdom Overseas Technical helpline Tel: +44 23 8029 5481 Fax: +44 23 8029 5111 Information hotline Tel: +44 (0) 23 8029 5029 Fax: +44 (0) 23 8029 5437 cables.marketing.uk@prysmian.com For further information please see our dedicated FP website: www.fpcables.co.uk Ref:FP PLUS/03/11