MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Similar documents
HOTLINE:

Thank you for choosing EnviroVent

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent

Wiring the fan correctly...

HOTLINE:

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

ECo 2 Wall INSTALLATION GUIDE FOR ENGINEER / INSTALLER

November This product has been reconfigured Please read these instructions

Wiring the fan correctly...

230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5

ECo 2 Wall USER GUIDE FOR RESIDENT

PIV & MIV Loft Mounted Unit INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Watch the heatsava video

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Installation and Maintenance

Installation and Maintenance

Installation and Maintenance

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Installation and Maintenance

Installation and Maintenance

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

KUDOS. Instruction leaflet

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Installation and Maintenance

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Purge Ventilation Unit. Product Manual. ventilation systems TP625

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Installation and Maintenance

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX

CLASSIC-100. Instruction leaflet. Instruction leaflet

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

Lo-Carbon Quadra Centrifugal Fan

Centrif Duo & Centrif Duo Plus

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

ECO dmev Decentralised MEV

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

FLAT2000L/R. Low Energy Positive Input Ventilation Unit. Installation and Maintenance. Alternative inlet position. 2.1 Spigot Inserts.

Introducing the RetroVent

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

INSTALLATION INSTRUCTIONS USER GUIDE

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

HI-LINE SUPER RC FAN CONVECTOR MODELS: 25-18,

60cm Integrated Turbo Extractor

Unity CV2GIP / CV2SVGIP Decentralised Mechanical Extract Ventilation (dmev) User / Homeowner Guide

Lo-Carbon SELV Tempra

ART cm Island Curved Glass

WC2 & WC3 Installation & Maintenance Instructions

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System User / Homeowner Guide

SLIM-LINE RC FAN CONVECTOR.

COOKER HOOD USER HANDBOOK FOR INSTALLATION AND OPERATION MODELS CRC95

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Fusion HRV2 Mechanical Ventilation with Heat Recovery User / Homeowner Guide

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

BLOW DRY & GO HAIR KIT

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

Stainless Steel and Glass Angled Extractor

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

WHHR Midi & Midi Lite

GUH90 90 cm Canopy Hood

Xpelair Simply Silent TM Contour Fan

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon Quadra Centrifugal Fan

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

HRX-aQ Range. Mechanical Ventilation with Heat Recovery appliances. Installation and Operating Instructions

100cm Chimney Hood GB IE

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

EH0533 Indoor Climate Control

MeacoCool MC Series Portable Air Conditioner

Stainless Steel Chimney Extractor

MODEL: BV400 Part No:

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

PANEL HEATER OPERATING INSTRUCTIONS. For Models: TWFP10000, TWFP PK

HINTS AND TIPS Cleaning and maintenance HELPLINE

Stainless Steel Chimney Extractor

GUH52SD 52 cm GUH75 75 cm Canopy Hood

Warnings, Safety Information and Guidance

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance

fact fact fact result No quibble, 7 year warranty. No strings attached. No fans going to landfill sites Happy tenants Money saved

Lucci Designer Hi Flow Exhaust Fan

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

I tho Advance. Heat recovery ventilation unit. User manual A6_ Ventilator Advance ENGELS.indd /0111/ED

100 FLUEBOOST

Lo-Carbon Quadra SELV

1.8l Rice Cooker. Instruction Manual

Transcription:

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION CHECK LIST Make sure that the unit can physically fit in to the desired location. The MEV Spider unit should be situated so that access for maintenance or replacement of parts is possible. Make the ductwork runs as short as possible. Having the most direct route and using as few bends as possible will reduce air resistance and improve the efficiency of the unit. SAFETY AND RECOMMENDATIONS All wiring must comply with Building Regulations and the current I.E.E. Wiring Regulations (BS7671) or the equivalent standards for your country. The final installation should be examined and tested by a qualified electrician. Precautions must be taken to avoid the back-flow of gases into the dwelling from the open flue of gas or other fuel-burning appliances. Make sure the mains supply complies with the rating label for voltage, frequency and phase. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. 1 MEV Spider SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON: 0345 27 27 810

Wiring Electrical Connections The appliance must be earthed and a double pole switch having a minimum contact separation of 3.0mm must be used to provide isolation for the unit. All wiring must be completed by a qualified electrician. This appliance is suitable for 230V ~ 50Hz single phase supply fused at 3 amps. The appliance is supplied with a 3 core mains flexible cable. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Emergency Shutdown Details Unit to be isolated from the mains by turning it off at the isolating point. Wiring Diagrams Remote control version (MEVS-W) Humidity version (MEVS-H) After Sales Service We recommend you do not dismantle or remove any other parts than those mentioned, as any tampering would automatically cancel the guarantee. If you detect any fault please contact EnviroVent. AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 2

Technical Specifications Dimensions Supply Voltage 230V / 50-60Hz / 70W Max / 0.5 A Max Ø125 30 Dimensions H 198mm x W 440mm x D 198mm 300 357 Ventilation Capacity Weight 135 l/s @ 100pa. Max 151 l/s (545m 3 /h) Boxed 5.8kg Unit 4.3kg 380 440 198 Performance Curve 3 MEV Spider SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON: 0345 27 27 810

Thank you for choosing EnviroVent The fastest growing ventilation company in the UK You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore ensure that this product is treated with care and installed properly i.e. for the life of the building. If the unit is mishandled you might break it! This invalidates the warranty. And remember, if you have any problems please call our dedicated Technical Team. We are always pleased to help and in an emergency will come out to site quickly, completely free of charge. About the unit The EnviroVent MEV Spider is a low-energy, continuous mechanical extract ventilation system designed with multiple extract points to simultaneously draw moisture-laden air out of the wet rooms, whilst minimising the migration of humidity to other rooms. The extract unit is centrally located in, for example, a hallway cupboard, with ducts running from the unit to the kitchen, bathroom, en-suite and other wet zones. The unit is suitable for houses, apartments and communal residences with kitchen plus up to 6 additional wet rooms, providing high centrifugal performance with low running noise. Highly cost effective and value for money, the MEV Spider comes with a full five year guarantee. Exploded view Lid Commissioning panel Electronics assembly Fan scroll and fan Ø100 input Black box Ø125 spigot extract to atmosphere Made in Harrogate UK AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 4

Box Contents Description Quantity Item MEV Spider Unit 1x Spigots 3x Spigot Blank 1x Fixing Kit 1x - Screw 8G X 2.0 4x - Washers 4x - Plasterboard Plugs 4x - Adhesive Foam Pads 8x - Rubber Sleeve 4x 5 MEV Spider SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON: 0345 27 27 810

Installation Instructions Mounting the unit 1. The unit maybe installed in any vertical or horizontal orientation. 2. Use the unit as a guide to mark fixing holes on the mounting surface ensuring clearance around the MEV unit. Drill 4 x Ø8mm holes, position wall plugs in the mounting surface and foam pads on the back of the unit s mounting tabs. 4. Attach fixings 5. Secure the MEV unit on all four corners. 3. Side view of fixings. AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 6

Installation Instructions Connecting the ductwork 1. Scribe around the outer edge of the required spigot blank MAX x 3 (a). Knock out the blank with a light tap (b). 4. Push in spigot and fix with self tapping screws provided. (a) (b) 2. Remove blanks from inside the unit. 5. Ductwork, ridged and flexi must be securely fixed. 3. It may be necessary to remove excess material with a knife. 6. If a blank is removed in error, the spigot hole must be filled with the spare blank provided. Firmly glue in place. To connect unit to mains supply, see pages 1-2 7 MEV Spider SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON: 0345 27 27 810

Controls Intellitrac Humidity Tracking (Automatic) When the MEV unit senses a rise in humidity, caused by increased moisture generation such as through cooking or showering, the extract and supply airflows will slowly begin to increase in direct proportion to the increase in humidity. It will then automatically track back down again when humidity falls. This controls condensation quietly and efficiently. Boost - Wall Switch The MEVS-H comes with a boost switch as standard to activate boost when required. The unit will remain at boost for as long as the switch is on. Boost - Remote Control The MEVS-W unit comes with a remote control switch to activate boost. The unit remains at boost for 20 mins. See page 9 for further information. Commissioning Boost controls The MEV Spider operates continuously on Normal setting to ensure the home is ventilated at the appropriate level although you can boost the system via the wired or remote control switch, if fitted. For remote control switches, press the button once, the green LED will light up and the unit will go to boost. The boost time is set to 20 minutes as standard. Batteries When the battery requires changing, unscrew the switch front cover. The battery is located on the back of the cover. Battery type - 3V Lithium, CR2032. Ensure that the new battery is inserted with the correct polarity and that the exhausted battery is removed and safely disposed of. To pair additional remote control switches (wireless units only) 1. Turn the unit off at the isolation point. 2. Restore power; for 20 seconds from restart the unit will be in pairing mode. 3. Press the remote button once within the 20 seconds and the control will pair to the unit. 4. Successful pairing is indicated by a green light on the control. Remote control Flashing red LED = not paired Constant green LED = paired Remote control button AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 8

Commissioning Setup guide for the MEV Spider The control switch is found behind the front cover. Commissioning mode is chosen by pressing the SET button for 4 seconds, all sensor inputs will be disabled in this mode so that they do not interfere with flow rates. LEDs will light with the Trickle flashing, this indicates that the flow rate may now be increased/ decreased as required. The next press of the SET button will move commissioning to the next setting, Boost. When the unit has been fully commissioned, press the SET button for 4 seconds and this will put the unit back into status mode. If the unit is not put back into status mode after commissioning, it will automatically revert back to status mode after an hour or if the power is turned off. Note: Settings will be retained if the power supply is interrupted. LED Indications Constant LED Flashing LED B - Humidity C - Boost State B - Service required Boost and trickle LED indications Commissioning mode only 9 MEV Spider SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON: 0345 27 27 810

Commissioning Commissioning of a continuous running Multiple Extract Ventilation system - MEV Commissioning of the system is necessary to provide adequate ventilation to the dwelling, as stipulated in Approved Document F (ADF) of the Building Regulations* Conditions All maintenance and development works should be completed prior to the commissioning of the unit, this is to avoid high levels of dust being drawn into the system and general disturbance to the setup. The unit should only be commissioned when fully installed, with power, ductwork, valves and vents in place. See Domestic Ventilation Compliance Guide. Equipment required Anemometer which is capable of measuring l/s or m³/hr. Commissioning method Once the previous conditions are met, boost and trickle rates need to be set. These should be set as outlined in the commissioning guide (pages 8-9). Ensure all internal & external windows and doors are closed. Required background vents are in the open position. See relevant guides. Commissioning guide Boost rate (minimum high rate) Determine the whole building extract ventilation rate. See ADF of the Building Regulations. Open ceiling/wall valves. Measure all extract points summing the individual room rates. Measurements to be carried out with an appropriate anemometer. Adjust using and buttons, press up or down until the total extract rate is met. See the individual product s instruction guide for method (pages 8-9). When the desired overall extract rate is achieved, the individual valves should then be adjusted to draw the appropriate volume of air from each room, typically starting with the largest extract requirement first: kitchen, bathroom, utility room, en-suite and WC. It may be necessary to adjust the fan unit slightly to account for increased pressure. When adjustments are completed the valves should be locked into position to maintain settings. Trickle rate This should be set to the whole building ventilation rate. See ADF of the Building Regulations. As the valves have been commissioned at boost they will not need to be altered further, the trickle buttons should be adjusted up or down, until the lower extract rate is met. See the individual product s instruction guide for method on pages 8-9. For guidance on good installation practice for MEV systems see the latest edition of the of the Domestic Ventilation Compliance Guide*. This guide provides in depth information on all aspects installation, inspection, testing and commissioning. *Applicable in England and Wales. For other countries please refer to your local building regulations. AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 10

Checklist Checklist to ensure Guaranteed Installed Performance MEV Spider installation instructions have been understood Ductwork to the unit is Ø100mm or larger, from the unit is Ø125mm or larger. No more than 10% flexi used (90% rigid) Duct in unheated areas is insulated All ducts, vents and diffusers are securely connected & sealed The unit is securely fixed into position with enough space left for servicing All major building works have been completed prior commissioning Unit has been commissioned to meet Part F of the Building Regulations with a calibrated anemometer Commissioning data has been recorded Inform building owner/user on how to operate and maintain the system These checks are required to ensure the proper function of this unit. For EnviroVent Technical help call 01423 810 810 11 MEV Spider SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON: 0345 27 27 810

Maintenance There are no special requirements for any maintenance within a five year period. The unit is easy to clean by simply removing the lid and motor plate. After carrying out work, make sure all the screws are in place. Cleaning Isolate the unit from electrical mains supply before removing any cover, or servicing the unit. 1. Remove 4 screws on top of the lid. 2. Remove 4 screws on top of motor plate. Pull backwards from the spigot and then lift up. Motor mounting remains attached to the main case via cabling. 3. After maintenance replace all components and fixing screws. AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 12

Warranty Conditions & Exclusions The EnviroVent MEV Spider is covered by a full 5 year warranty which will benefit the occupier over many years. The unit will be set according to the size of the property and will operate continuously. There is no requirement for any maintenance within the 5 year period. What should I do if I have a problem? If, after thoroughly reading this booklet, you feel that your MEV Spider is not working correctly, you can telephone 0345 27 27 810 (operational from 8:00am to 5:00pm Monday to Friday), and ask for technical assistance. You will either be given guidance over the telephone, or an arrangement will be made for an engineer to visit. In any event, please have the following information ready. This will enable your call to be dealt with quickly and efficiently. Please note that proof of purchase by the way of a receipt is required and that any fans bought from an unapproved source, including but not limited to Ebay, will render the guarantee invalid. Serial number of the unit We appreciate you choosing this quality EnviroVent product, which is designed and manufactured to the highest specification in Harrogate, North Yorkshire. We are confident that you will be delighted with the performance of the system and the resulting improvement in air quality in your home after the installation of the unit. Your warranty covers any defect or break down that arises due to faulty materials or construction. Terms of Warranty The system must be correctly installed and operated according to the instructions contained in the user guide supplied. The warranty will be rendered invalid if the system has been serviced, maintained, repaired, taken apart or tampered with by any person not authorised by EnviroVent Ltd. The warranty will be rendered invalid if the unit is turned off. Turning the unit off can damage it. The warranty does not cover accidental damage, misuse or abuse. The warranty is in addition to your statutory or legal rights. The guarantee will only be honoured from approved suppliers. 13 MEV Spider SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON: 0345 27 27 810

Delivering innovative and sustainable ventilation solutions worldwide EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate HG2 8PA T / 01423 810 810 F / 01423 301 022 E / info@envirovent.com W / envirovent.com Please read carefully to ensure simple installation and a long trouble free life for the user. AFTER INSTALLING THIS FAN PLEASE PASS ONTO END USER DO NOT THROW AWAY E&OE MKT ENV230-V10-02.01.18 Due to our policy of continuous innovation and improvement EnviroVent reserves the right to alter products specification and appearance without notice. We want to hear from you Your feedback is important to us as we strive to improve our products, services, and overall customer experience. Please email us to help us serve you better: feedback@envirovent.com