Fire Risk Assessment

Similar documents
Fire Risk Assessment

Fire Risk Assessment

Fire Risk Assessment

LYHA Fire Safety Policy

NOTTINGHAM CITY HOMES

Fire risk management plan. MH/05/Revised/06/17

TYPE 1 FIRE RISK ASSESSMENT REVIEW (NO DESTRUCTIVE AUDIT)

Fire Safety Protocol

Independent Living Scheme Fire Risk Assessment. Independent living sheltered residential accommodation and public library

FIRE RISK ASSESSMENT NOT KNOWN 15/10/ SOMERTON COURT BROADMOSS DRIVE SIMON ROFFEY

Slight Harm Moderate Harm Extreme Harm Low Trivial Risk Tolerable Risk Moderate Risk Medium Tolerable Risk Moderate Risk Substantial Risk

General needs sleeping accommodation

fire risk assessment For use by landlords of small premises Premises Address

Health & Safety Policy HSP 03 Fire Safety Version Status Date Title of Reviewer Purpose/Outcome

Independent Living Scheme Fire Risk Assessment. Independent Living Sheltered residential accommodation

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

Fire Safety in Communal Areas Policy

WILTSHIRE POLICE FORCE PROCEDURE. Fire Safety Management

NOT PROTECTIVELY MARKED. Fire Legislation

Fire Risk Assessment

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

Fire precautions in dwellings

Independent Living Scheme Fire Risk Assessment. General needs residential sleeping accommodation

Fire Safety Policy. Document Author: Director of Estates, Fleet & Facilities Management

Fire Safety Policy. Billy Hanafin H & S and Operations Officer. Fife Cultural Trust. Version 1.0 October 2013 Page 1

Millfield Schools Fire Risk Prevention Policy

Management Standard: Fire Safety

Fire. This policy applies to all members of our school community, including those within the EYFS setting.

FIRE RISK ASSESSMENT. Hatton House. Page 1 of 21

Fire Risk Assessment Guidance

CYNGOR SIR POWYS COUNTY COUNCIL

Charlotte Building, 17 Gresse Street, London W1T 1QL

Dan Gray, Property Director. Date: November 2017 Review Due Date: November 2020

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

Fire Risk Assessment Guide

Fire Risk Assessment Safety Checklist

Arbour House. Fire Policy and Procedures

Fire Safety Policy Date: 0

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

FIRE RISK ASSESSMENT

Fire Risk Assessment. Index. Part 1 Introduction Part 2 The Fire Risk Assessment Part 3 The Management Action Plan

FIRE RISK ASSESSMENT Self Assessment

Fire Risk Assessment 2017

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Fire safety procedure

FIRE SAFETY LOG BOOK

The Regulatory Reform (Fire Safety) Order Fire Risk Assessment Report

FIRE SAFETY & EMERGENCY EVACUATION STRATEGY AND POLICY

Wellsprings Primary School. Fire Emergency Evacuation Plan

FIRE RISK ASSESSMENT CHECKLIST

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing)

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

HEALTH & SAFETY MANAGEMENT ARRANGEMENTS FOR FIRE SAFETY

FIRE SAFETY POLICY. Executive Management Team. Health, Safety and Fire Steering Group.

Fire Safety Procedures & Risk Assessment Policy

FIRE SAFETY POLICY Revised March 2013

Fire Safety Policy (Communal Areas)

Fire Safety. A TUC guide for trade union activists

HOMES FIRE RISK ASSESSMENT. Hatton House. Page 1 of 24

Fire Safety Management

Fire Safety Strategy

Element C3.5 Means of Escape

St Edward s Oxford FIRE SAFETY POLICY

Allfire Site No. a division of Allsaved Ltd. Fire Safety Log Book. Premises Address: Responsible Person:

KING S HOUSE SCHOOL FIRE RISK MANAGEMENT POLICY & PROCEDURES

FIRE SAFETY POLICY June 2014

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

FIRE EMERGENCY PLAN AND FIRE RISK (PREVENTATION) POLICY

FIRE SAFETY RISK ASSESSMENT

Fire Risk Assessment Guide

Regulatory Reform (Fire Safety) Order 2005 Category of Premises against the FSO 2005: Sleeping Accommodation

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

Electrical Safety Policy and Management System

Fire Risk Assessment Case Study

FIRE SAFETY POLICY. This policy refers to both Wellington Senior School and Wellington Prep School

- CONSTRUCTION FIRE SAFETY STANDARDS

GDST Fire Safety Strategy March 2016

FIRE SAFETY RISK ASSESSMENT

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

FIRE RISK ASSESSMENT Retirement Housing (Independent Living) (v3.november 2016)

Fire Risk Assessment

Fire Safety, Procedures and Risk Assessment Policy

Fire Safety Policy 2018/19

Fire Safety Policy. (The Regulatory Reform (Fire Safety) Order 2005) Last Reviewed: January Next Review: January 2019

Loss Prevention Standards

Q) What should I do if the fire alarm sounds in the building? Q) What do I do if I discover a fire?

Fire Safety Policy. Investing in success. Dukes Centre Dukes Avenue Kingston KT2 5QY 1. Policy

GHS 8-4 Fire Policy and Procedures

Periodic Electrical Testing Policy

Fire Risk Assessment Guide

Fire Safety Management

Annemount School Fire Safety Policy This Policy is for the whole school including the EYFS

June 2017 (Updated 18 January 2018) Fire Safety Policy. Peter Webb, Project Manager Compliance First Choice Homes Oldham Limited

FIRE ALARM SYSTEMS FOR PURPOSE-BUILT FLATS & APARTMENTS: A NEW APPROACH

A GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO)

FIRE POLICY ST.GEORGES AND OUR LADY QUEEN OF PEACE PARISHES OF WORCESTER INTRODUCTION. Fire is one of the most common workplace hazards.

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

Property Health and Safety Compliance at Housing and Education Centres

Statutory Compliance Checklist

Transcription:

Fire Risk Assessment Trinity House HS.F.119 (rev02) delivering promises, improving lives

Contents 1 Premises particulars... 1 2 General statement of policy... 1 3 Management systems... 1 4 General description of premises... 2 5 Fire safety systems within the premises... 3 6 Plan drawing... 3 7 Identify fire hazards... 3 8 Identify people at risk... 4 9 Means of escape - horizontal evacuation... 4 10 Means of escape - vertical evacuation... 4 11 Fire safety signs and notices... 4 12 Fire warning system... 5 13 Emergency lighting system... 5 14 Fire-fighting equipment... 5 15 Management - maintenance... 5 16 Method for calling Fire Service... 6 17 Emergency action plan... 6 18 Training... 6 19 Fire safety deficiencies to be rectified... 7 20 Significant findings... 7 21 Additional hazards... 7 Appendix A: Floor plans... 8 Fire Risk Assessment High Rise HS.F.119 (rev02)

1 Premises particulars Premises name: Trinity House Address: George Street, Wakefield Phone : 07786028581 Date of Risk Assessment: May 2018 Fire Risk Assessment Use of premises: Domestic dwellings Owner / employer/ person in control of the workplace: Kevin Dodd, Chief Executive, WDH Date of Review: May 2019 Name and relevant details of the person who carried out the Fire Risk Assessment: Daniel Boardman, Property Compliance Manager CMIOSH 2 General statement of policy Statement: Good health and safety is integral to good management. We aim to make sure that it continues to be part of the culture of WDH. Employees should have health, safety and welfare objectives agreed with managers and throughout WDH. We recognise that complying with the Health and Safety at Work Act 1974, and the regulations made under it, is a legal duty, not a matter of choice. Our policy should exceed the minimum requirements of the law where possible and to do this we will provide sufficient resources to meet this commitment. We will also ensure that systems are in place that will allow us to maintain, monitor and continuously improve safety performance. Included in these systems will be the means to allow communication and consultation on health and safety matters between all levels within WDH. This risk assessment only covers the common areas within the building and does not cover the inside of individual apartments. 3 Management systems : The Fire Safety Policy is provided for all employees on our intranet Health and Safety pages. This confirms that a fire risk assessment will be undertaken on all premises to which the Regulatory Reform Order (RRO) applies. The Property Compliance Manager has responsibility for fire safety issues which includes fire risk assessments and all matters relating to fire safety. Inspection and servicing of dry riser systems are undertaken twice every year by Chubb engineers. Any repairs to a dry riser are carried out by our Specialist Services Team. Chubb fire services inspect and service all fire-fighting equipment in the building. All common areas are monitored by caretakers on a weekly basis to ensure they are kept sterile. Records are sent to our Property Compliance Team for filing and reported to the Health and Safety Committee. Emergency lighting is tested monthly by our Electrical Team, records of tests are kept on site. Fire Risk Assessment High Rise HS.F.119 (rev03) 1

A programme is in place for the PAT testing of electrical equipment used by caretakers and cleaners. The entrance / exit security system provides for occupants to escape out of the fire exits by a fail to safe system. 4 General description of premises Description Trinity House is a 14 storey high rise residential building with 46 individual apartments. The apartments are let to single tenants or married couples, 10 one bedroom apartments and 36, two bedroom apartments. families are allocated tenancy in these buildings. However, we are not always made aware if children move into the block either through tenants relationships or if the tenant has a child whilst living in the apartment. The building construction consist of, steel pitched roof, concrete and brick construction, PVCu windows, Aluminium Dorma electrically operated main entrance doors, PVCu side entrance doors, steel rubbish chutes and bin store doors. Bin store has a Hardhalls automatic closer to ensure any fires which may start in this area are prevented from entering the common areas of the block. Trinity House is a well maintained building which provides good clear and well illuminated fire exits from the building. These facilities are maintained on a regular basis and monitored weekly by the resident caretaker. Emergency access is provided by a secured key arrangement to the Fire Service. The entrance/exit security system provides for occupants to escape out of the fire exits by a fail to safe system. Each apartment is compartmentalised and only where services pass between storeys would this be compromised. These areas will be checked and seals replaced where required. Cladding Alumasc phenolic insulation boards, glassfibre reinforcing mesh or lath, and spardash or plain render finishes. The systems are classified Class 0 fire rated. Occupancy Times the premises are in use: 24/7 The total number of persons employed within the premises at any one time: 1 The total number of persons who may reside the premises at any one time: 90+ Size Building footprint: 20m x 20m Number of storeys: Ground + 13 Number of stairs: 1 Fire Risk Assessment High Rise HS.F.119 (rev03) 2

5 Fire safety systems within the premises Fire warning system Individual apartments have hard wired detection systems installed. There is no fire detection in the common areas. Emergency lighting Emergency lighting conforming to BS5266 provided throughout the building. Fire doors 60 minute fire rated doors on apartment entrances and 30 minute fire rated doors in all communal areas. Bin chute closers Certificate up to date and available electronically. Dry riser outlets t damaged or tampered with. Smoke ventilation Natural ventilation shaft on each landing. Sprinkler system Alarm system in corridors Key safe in place undamaged and full set of keys in place 6 Plan drawing Full set of drawings attached at Appendix A. 7 Identify fire hazards Sources of ignition hot works on premises, general electrical points present but these are subject to periodic testing in line with the Electrical Regulations 17th Edition. Work processes Any hot works which would take place as part of the repair and maintenance within this building would be managed through the Hot Works Permit system currently in place within WDH. Structural features that could promote the spread of fire, include external cladding Where services pass throughout the building these have fire rated materials to prevent the spread of fire and smoke. External cladding fitted to this building. Alumasc phenolic insulation boards, glassfibre reinforcing mesh or lath, and spardash or plain render finishes. The systems are classified Class 0 fire rated. This is secured direct to the structure of the building and therefore does not have any air gaps between the building and the cladding. Fire Risk Assessment High Rise HS.F.119 (rev03) 3

Items stored within common areas All clear We have a zero tolerance approach to common areas in high all high rise buildings. Is there gas piped into the building? 8 Identify people at risk Identify and specify the location of people at significant risk in case of fire, indicating why they are at risk, and what controls are or need to be in place Tenants living in these buildings are able bodied and any issues would be discussed at start of tenancy, however their health may deteriorate over the life of the tenancy, we would not always be aware of this so our advice to tenants is they should only evacuate if their particular apartment was on fire. All tenants are provided with a leaflet, titled Fire safety in high rise residential buildings ; this provides tenants with actions to take if an emergency occurs within this building. This information is also available on our website with instructions on what action tenants should take in an emergency. This notice is displayed in the foyer in the block. 9 Means of escape - horizontal evacuation In an emergency the lift would go to the ground floor and the doors would open allowing anyone in the lift to exit. The stairways and common areas are maintained as sterile areas so the likelihood of a fire in the common area are low. Evacuation for tenants would be through the stairway. See plans at Appendix A. 10 Means of escape - vertical evacuation The stairways and common areas are maintained as sterile areas so the likelihood of a fire in the common area are low. Tenants would evacuate using the one stairway which leads to two available exit doors. In event of a fire tenants would access central stairs in the centre of the building which is protected at the end of each wing. See Plans at Appendix A. The entrance/exit security system provides for occupants to escape out of the fire exits by a fail to safe system. 11 Fire safety signs and notices The building has an adequate number of signs which comply with the Safety Signs and Signals Regulations 1996. All exit routes are adequately marked along with fire-fighting equipment. Smoking signs are displayed throughout the building. Low level signage is on stairwells to enable the Fire Service to identify which floor they are on if the area is smoke filled. Fire Risk Assessment High Rise HS.F.119 (rev03) 4

12 Fire warning system Individual apartments have hard wired smoke detection. 13 Emergency lighting system The emergency lighting system is serviced and maintained in-house, is adequate and meets the needs of the building. The system is serviced and tested by our Specialist Services engineers. The system complies with BSEN60598.2.22. 14 Fire-fighting equipment Dry riser outlets are serviced by Chubb twice a year and certificates available electronically. CO2 fitted in the lift motor room. All on site fire-fighting equipment has been serviced by Chubb and certificates are available electronically. 15 Management - maintenance Is there a maintenance programme for the fire safety provisions in the premises? Chubb undertake servicing and replacement of all fire-fighting equipment. Smoke detectors are fitted in tenants apartments. Tenants advised to test these regularly. Are regular checks of fire exit doors, walls and partitions carried out? Carried out weekly as part of the caretakers checklist. Are regular checks of escape routes and exit doors carried out? : Carried out weekly as part of the caretakers checklist. Are regular checks of fire safety signs carried out? Carried out weekly as part of the caretakers checklist. Is there a maintenance regime for the fire warning system? ( fire warning system) Weekly by Facilities Management. Annually by in-house team and recorded. Fire Risk Assessment High Rise HS.F.119 (rev03) 5

Is there a maintenance regime for the emergency lighting system? : Electrical Team service and maintain lighting Six Monthly systems Annually Is there maintenance of the fire-fighting equipment by competent persons? : Carried out as part of the caretakers checklist. Annually by Chubb and recorded. Are records kept and their location identified? : A set of CAD drawings are available for the building showing where fire-fighting equipment is located. (See Appendix A). 16 Method for calling Fire Service Specify Tenants or the caretaker would call the Fire Service in the event of an emergency. Caretakers, if on site, would assist and inform OneCALL. 17 Emergency action plan Only tenants who s apartment is directly affected by fire would evacuate. All apartments have been compartmentalised with 60 minute fire rated doors on apartment entrances and 30 minute fire rated doors in all communal areas and fire stoppage in place where services pass horizontally or vertically throughout the building. Our tenants were all provided with a leaflet on sign up around fire safety in high rise residential buildings. This information is available on our website with instructions on what action tenants should take in an emergency. tices in foyers also advise tenants on what action they should take in an emergency. 18 Training Training in fire safety is provided to our employees by the Health and Safety Section. Fire Risk Assessment High Rise HS.F.119 (rev03) 6

19 Fire safety deficiencies to be rectified Deficiency and rectification Ensure any areas which require actions are closed off Priority Date to be rectified Responsibility Date rectified Insert additional pages as required 20 Significant findings Significant finding ne. Control measure and action 21 Additional hazards Specify Need to consult Fire Service Fire Risk Assessment High Rise HS.F.119 (rev03) 7

Appendix A: Floor plans For Fire Service use only Fire Risk Assessment High Rise HS.F.119 (rev03) 8