Programmable 5-2 Day Digital Thermostat

Similar documents
Non-Programmable Digital Thermostat

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

HEAT COOL 5+2 DAY PROGRAMMABLE 1-STAGE HEAT, 1-STAGE COOL. Installation Instructions TSTATCCPQ501 TSTATBBPQ501 P Digital Thermostat I2:00

OWNER'S MANUAL T0140. Contents Page #

Programmable 5-2 Day Digital Thermostat

Owner s Manual. Digital Thermostat. Non-Programmable

5+2 DAY INSTALLATION. Digital Thermostat. residential. & 1-cool. up to. 1-heat PROGRAMMABLE HEAT COOL HEAT PUMP THERMOSTAT. Venstar Inc.

5+2 DAY PROGRAMMABLE DIGITAL THERMOSTAT

Installation Instructions

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

Owner s Manual. Digital Thermostat

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

2 - Wire Programmable Digital Thermostat

Thermostat Remote Control & Receiver

Humidity Module OWNER S MANUAL. Complete Control from

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

5+2 Day. up to HEAT COOL

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

7-Day. Digital Thermostat. residential. & 2-cool

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEU22P7S RESIDENTIAL. Model HVAC SERVICE PARTS

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

Small Digital Thermostat Controller Temperature Control

Programmable Digital Thermostat

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Installation Instructions

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Owner s Manual. 5+2 Day Programmable Digital Thermostat

1 For All Programmable Digital Thermostat

Installation Instructions

Installation Instructions

Programmable Digital Thermostat

Legacy Non-Programmable Owner s Manual

TC --- NHP, TC --- NAC Comfort Series Non---Programmable Thermostat. Owner s Manual

5+2 Day. up to HEAT COOL

MULTI HEAT PUMP PANEL CASSETTE TYPE DUCTLESS INVERTER INDOOR UNIT OWNER'S MANUAL. Models: CH12CC230VI CH18CC230VI CH24CC230VI

Performance Non-Programmable Owner s Manual

Installation Instructions HEAT COOL FAN POWER

Installation Instructions

User s Information Manual

user s information manual

Auto-Changeover: Cool Setpoint: Deadband: Differential: Heat Setpoint: Icon: Mode: Non-Programmable Thermostat: Programmable Thermostat:

CT500 Electronic Thermostat

Compatibility. Contents. Necessary Tools

Safety & Installation Instructions

7-DAY or 5/2-DAY PROGRAMMABLE, OR NON-PROGRAMMABLE THERMOSTAT INSTALLATION AND OPERATING INSTRUCTIONS

Performance Non-Programmable Owner's Manual

Installation, Start -Up, and Operating Instructions

Quick Start & Setup Guide

Safety & Installation Instructions

INSTALLER S & OWNER S MANUAL

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Venstar Inc. 08/07

CTS Series. Owner s Manual. Full Color Touch Screen Display. and Installation Instructions. High Resolution Digital Thermostat

WARNING Important Safety Information

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

Installation Instructions

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047

Optima ZigBee Thermostat

NON- INSTALLATION INSTRUCTIONS Venstar Inc. 08/07. Digital Thermostat T2700. commercial. & 2-cool. up to 2-heat PROGRAMMABLE

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

WARNING Important Safety Information

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

CT2700 An Electronic Round Programmable Thermostat

HEAT HEAT HEAT COOL COOL

Installation Instructions

Operation Manual. An investment of a small amount of time to review this manual will ensure proper performance of your Coal-Trol Digital system.

INSTRUCTIONS! DO NOT DISCARD!

7-Day. Digital Thermostat. residential. & 2-cool

WARNING Important Safety Information

ITEM # SAIL STREAM CEILING FAN MODEL #41695

CT2800 Programmable Thermostat

asy Single Day up to 2-heat & 2-cool Stat

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

ITEM # HYDRA CEILING FAN MODEL #41371

Owner s Manual. Premier Series Digital Thermostat. and Installation Instructions. Non-Programmable with Humidity Control COMMERCIAL

DIGITAL THERMOSTAT. I2:00 Su AUTO OPTIONAL HUMIDITY MODULE

Safety & Installation Instructions

MagicStat CT3300 Programmable Thermostat

INSTALLER S & OWNER S MANUAL

Digital Programmable

with Wi-Fi and local API Quick start and setup guide

1 PREPARATION 2 THERMOSTAT MOUNTING DIMENSIONS. CT70A Heat Pump Thermostat. Your Honeywell Thermostat. Recycling Notice. Do-It-Yourself Models

INSTRUCTIONS! DO NOT DISCARD!

Residential Duct Mount Builder s Box Media Air Cleaner

For Quick Set-Up go to Page 14

Home and Building Control Home and Building Control Helping You Control Your World

ITEM # SAIL STREAM CEILING FAN MODEL #40048

TOUCHDOWN 48 CEILING FAN

ITEM # , CARATUK RIVER CEILING FAN MODEL #40046, 40303

Operator: Save these instructions for future use!

1F90-60 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 5 Day/2 Day Electronic Digital Thermostat (for Heat Only Systems)

INSTRUCTIONS! DO NOT DISCARD!

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCNB001 TSTATBBNB001 P Digital Thermostat

WARNING Important Safety Information

OWNER S MANUAL Venstar Inc. 08/07

Transcription:

P/N TSTAT0712 Programmable 5-2 Day Digital Thermostat 1 STAGE HEAT COOL THERMOSTAT SINGLE STAGE HEAT PUMP COMPATILE (Does not control auxiliary heat) Separate rams for weekdays & weekends Large, easy to read, backlit digital display atteries required for 4-wire operation No batteries needed for 5-wire operation 1 stage heat/cool - gas/electric or heat pump Use with most Air Conditioning & Heating Systems including: 1 Stage Electric Cooling & Gas Heating, Heat Pump, Electric or Hydronic Heat. International Comfort Products 2004

Contents Page # Safety Warnings Preparation Remove Old Thermostat Installation/attery Replacement Wire Connections Jumper Configuration Test Operation Troubleshooting Warranty Page 2 Page 2

CAUTION CAUTION Safety Warnings P/N TSTAT0712 Follow Installation Instructions carefully. DISCONNECT POWER TO THE HEATER - AIR CONDITIONER EFORE REMOVING THE OLD THERMOSTAT AND INSTALLING THE NEW THERMOSTAT. WARNING The 2 Alkaline AA batteries must be replaced at least every 12 months to assure proper operation. The thermostat will display the Low attery code (fig. 1) on the display of the thermostat when it is time to replace the batteries. If the thermostat is connected to 24v power, the atteries may still be installed, but are not required. When L8 is displayed the batteries must be replaced immediately. The manufacturer cannot be liable for improper operation of the thermostat if the batteries are not immediately replaced. The annual battery replacement is especially critical in locations subject to freezing temperatures. The thermostat will be unable to turn on the Heat if the batteries are exhausted. This device complies with Part 15 of the FCC rules. Operation is subject to the following 2 conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. International Comfort Products 2004 Page 3 L8 FIG. 1

INSTALLATION INSTRUCTIONS Step #1 Preparation Proper installation of the thermostat will be accomplished by following these step by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance. These tools will be required: Flat lade Screwdriver Wire cutter & Stripper Make sure your Heater/Air Conditioner is working properly before beginning installation of the thermostat. Carefully unpack the thermostat. Save the screws and instructions. Turn the power to the Heating/Air Conditioning system at the main fuse panel. Most residential systems have a separate breaker for disconnecting power to the furnace. Page 4

INSTALLATION INSTRUCTIONS Step #2 Remove & Replace Old Thermostat Remove the cover of the old thermostat. If it does not come easily check for screws. Loosen the screws holding the thermostat base or subbase to the wall, and lift away. Disconnect the wires from the old thermostat. Tape the ends of the wires as you disconnect them, and mark them with the letter of the terminal for easy reconnection to the new thermostat. Keep the old thermostat for reference purposes, until your new thermostat is functioning properly. Page 5

Step #3 Open The New Thermostat Installation / attery Replacement The top of the thermostat housing has two (2) screwdriver slots to assist when seperating. SCREWDRIVER SLOTS To pull the housing apart, insert a small blade screwdriver into the slot and rotate 90. This will release the top housing snaps. Repeat the procedure in the other screw driver slot. Separate the housing halves by pulling the top forward until the pins release, and then lift the bottom out. The batteries must be replaced immediately when the thermostat displays the Low attery code (fig.1). L8 FIG. 1 Page 6

4Z95 INSTALLATION INSTRUCTIONS Step #4 Wire Connections If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below, or the wiring diagrams that follow. Wire from the old thermostat terminal marked Function Install on the new thermostat connector marked W1, W or H Heating W 1 or Cooling Rev. Valve (Energize to Heat) O Rev. Valve O (Energize to Cool) G or F Fan G Rh, R, M, Vr, A Power C Common C (optional) Thermal Insulating Sheet R A label is provided on the backplate that prevents drafts, originating inside the wall, from entering the thermostat. These drafts, left unchecked, may cause incorrect room temperature readings. Please do not remove this label from the thermostat. Insert the wires through the slots provided in the label as shown in Fig. 1 Wire Slots Page 7 C W O G R MODEL: ICP TSTAT0712 97061606 USE SIZE AA ALKALINE ATTERIES MADE IN CHINA Fig. 1

Sample Wiring Diagrams Gas or Electric Heat 4 Wire, 1 Stage Cooling, 1 Stage Gas Heat Residential Gas or Electric Heat *, Electric Cool, split systems & package units Common wire optional* C W O G R 4 Conductor 18 gauge unshielded cable from the thermostat to the equipment. POWER FAN COMPRESSOR GAS VALVE W G R * Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by the two AA Alkaline batteries (page 14). These batteries must be replaced each year or when the Low attery indicator is displayed (page 3, 6). Page 8

Sample Wiring Diagrams Gas or Electric Heat 4 Wire, 1 Stage Cooling, 1 Stage Heat-Heat Pump with O reversing valve. Residential Heat Pumps, split systems & package units, with no auxiliary heat. Common wire optional* C W O G R 4 Conductor 18 gauge unshielded cable from the thermostat to the equipment. POWER FAN REVERSING VALVE * COMPRESSOR G R O Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by the two AA Alkaline batteries (page 14). These batteries must be replaced each year or when the Low attery indicator is displayed (page 3, 6). Page 9

Sample Wiring Diagrams Gas or Electric Heat 4 Wire, 1 Stage Cooling, 1 Stage Heat-Heat Pump with reversing valve. Residential Heat Pumps, split systems & package units, with no auxiliary heat. Common wire optional* C W O G R 4 Conductor 18 gauge unshielded cable from the thermostat to the equipment. POWER FAN REVERSING VALVE * COMPRESSOR G R Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by the two AA Alkaline batteries (page 14). These batteries must be replaced each year or when the Low attery indicator is displayed (page 3, 6). Page 10

Sample Wiring Diagrams Gas or Electric Heat 3 Wire, 1 Stage Heat Residential Gas or Electric Heat units with a separately controlled fan. Common wire optional* C W O G R 3 Conductor 18 gauge unshielded cable from the thermostat to the equipment. POWER FAN GAS VALVE or STRIP HEAT G R W * Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by the two AA Alkaline batteries (page 14). These batteries must be replaced each year or when the Low attery indicator is displayed (page 3, 6). Page 11

Sample Wiring Diagrams Gas or Electric Heat 2 Wire, 1 Stage Gas Heat Residential Gas or Millivolt units. Common wire optional* C W O G R 2 Conductor 18 gauge unshielded cable from the thermostat to the equipment. POWER GAS VALVE W R * Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by the two AA Alkaline batteries (page 14). These batteries must be replaced each year or when the Low attery indicator is displayed (page 3, 6). Page 12

Sample Wiring Diagrams Gas or Electric Heat 3 Wire, 1 Stage Cooling Residential Electric Cool units Common wire optional* C W O G R 3 Conductor 18 gauge unshielded cable from the thermostat to the equipment. POWER FAN COMPRESSOR G R * Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by the two AA Alkaline batteries (page 14). These batteries must be replaced each year or when the Low attery indicator is displayed (page 3, 6). Page 13

INSTALLATION INSTRUCTIONS Step #5 Jumper Configuration IF THERMOSTAT IS NOT SSTEM POWERED REPLACE WITH ALKALINE ATTERIES ONCE EVER EAR USE AA SIZE ALKALINE ATTERIES USE AA SIZE ALKALINE ATTERIES ELEC GAS HP GAS If the HVAC unit has First Stage Electric Heat then jumper should be to ELEC. If the jumper is for ELEC, the fan will energize immediately on a call for heating. For all other applications this jumper should remain to the GAS position. If the HVAC unit is a residential Heat Pump, then jumper should be to HP. For all other applications this jumper should remain to the GAS position. Page 14

INSTALLATION INSTRUCTIONS Step #6 Test Operation Turn on the power to the Heating/Air Conditioning system. Adjust the Slide Switch until it is located under the word HEAT on the thermostat. Press the Up or Down buttons until the temperature is 10 degrees above room temperature. The HVAC unit should energize in the heating mode. Adjust the Slide Switch until it is located under the word COOL on the thermostat. Press the Up or Down buttons until the temperature is 10 degrees below room temperature. The HVAC unit should energize in the cooling mode. Adjust the Slide Switch until it is located under the word OFF. Adjust the other slide switch until it is located under the word Fan On. The fan should turn on and continuously. Page 15

INSTALLATION INSTRUCTIONS Trouble Shooting SMPTOM: The slide switches on the thermostat are very difficult to move. CAUSE: The backplate of the thermostat is deformed by being screwed tightly into a wall that is not perfectly flat. REMED: Loosen the screws holding the thermostat into the wall. SMPTOM: The backlight on the thermostat doesn t work. CAUSE: There is no common wire connected to the thermostat. REMED: In order for the backlight to energize a common wire must be connected to the thermostat. Install a common wire from the 24v transformer powering the thermostat. Page 16

INSTALLATION INSTRUCTIONS Trouble Shooting SMPTOM: The air conditioning does not attempt to turn on. CAUSE: The cooling point is too high or the Mode Switch is not for Cool, or the batteries are too weak. REMED: Consult the Normal Operation section of this manual to lower the cooling point and to correct the Mode Switch position, or replace the batteries. SMPTOM: The heating does not attempt to turn on. CAUSE: The heating point is too low or the Mode Switch is not for Heat, or the batteries are too weak. REMED: Consult the Normal Operation section in this manuals to raise the heating point and to correct the Mode Switch position, or replace the batteries. Page 17

INSTALLATION INSTRUCTIONS Trouble Shooting SMPTOM: The thermostat does not the ram correctly. CAUSE: The Program slide switch is not for RUN or the time periods are not in chronological order. REMED: Please be certain to ram each time period in chronological order to ensure proper rammed operation of the thermostat. For example, if the Morning Start Time is 6:30am, then the Day Start Time MUST be rammed for any time AFTER the 6:30am Morning Start Time. Also, if the Day Start time is for 10:30am, then the Evening Start Time MUST be rammed for any time AFTER the 10:30am Day Start Time. Finally, if the Evening Start Time is for 5:30pm, then the Night Start Time MUST be rammed for any time AFTER the 5:30pm Night Start Time. 4Z95 attery Stat FCc P/N TSTAT0712 Tested to Comply with FCC Standards FOR HOME OR OFFICE USE Page 18 P/N 88-429 Rev. 1

Warranty One-ear Warranty - This Product is warranted to be free from defects in material and workmanship. If it appears within one year from the date of original installation, whether or not actual use begins on that date, that the product does not meet this warranty, a new or remanufactured part, at the manufacturer s sole option, to replace any defective part will be provided without charge for the part itself; PROVIDED the defective part is returned to the distributor through a qualified servicing dealer. THIS WARRANT DOES NOT INCLUDE LAOR OR OTHER COSTS incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either defective parts or replacement parts. Such costs may be covered by a separate warranty provided by the installer. THIS WARRANT APPLIES ONL TO PRODUCTS IN THEIR ORIGINAL INSTALLATION LOCATION AND ECOMES VOID UPON REINSTALLATION. LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES (INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTAILIT) ARE HERE LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANT IS GIVEN. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANT LASTS, SO THE AOVE MA NOT APPL TO OU. THE EXPRESSED WARRANTIES MADE IN THIS WARRANT ARE EXCLUSIVE AND MAN NOT E ALTERED, ENLARGED, OR CHANGED AN DISTRIUTOR, DEALER, OR OTHER PERSON WHATSOEVER. ALL WORK UNDER THE TERMS OF THIS WARRANT SHALL E PERFORMED DURING NORMAL WORKING HOURS. ALL REPLACEMENT PARTS, WHETHER NEW OR REMANUFACTURED, ASSUME AS THEIR WARRANT PERIOD ONL THE REMAINING TIME PERIOD OF THIS WARRANT. THE MANUFACTURER WILL NOT E RESPONSILE FOR: 1. Normal maintenance as outlined in the installation and servicing instructions or owners manual including filter cleaning and/or replacement and lubrication. 2. Damage or repairs required as a consequence of faulty installation, misapplication, abuse, improper servicing, unauthorized alteration or improper operation. 3. Failure to start due to voltage conditions, blown fuses, open circuit breakers or other damages due to the inadequacy or interruption of electrical service. 4. Damage as a result of floods, winds, fires, lightning, accidents, corrosive environments or other conditions beyond the control of the Manufacturer. 5. Parts not supplied or designated by the Manufacturer, or damages resulting from their use. 6. Manufacturer products installed outside the continental U.S.A., Alaska, Hawaii, and Canada. 7. Electricity or fuel costs or increases in electricity or fuel costs from any reason whatsoever including additional or unusual use of supplemental electric heat. 8. AN SPECIAL INDIRECT OR CONSEQUENTIAL PROPERT OR COMMERCIAL DAMAGE OF AN NATURE WHATSOEVER. Some states do not allow the exclusion of incidental or consequential damages, so the above may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which may vary form state to state. Page 19