Multipoint Technical Data

Similar documents
UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

VENTED POINT-OF-USE HOT WATER PRODUCT RANGE

Hotflo. Unvented point of use hot water

ELECTRIC HEATING SOLUTIONS PRODUCT RANGE

Unvented water heating

HOTFLO 10 / 15. Fitting Instructions and User Guide

MECHANICAL VENTILATION & HEAT RECOVERY PRODUCT RANGE

Unvented Water Heaters. September Aqualine. Unvented Electric Water Heating

Streamline Undersink. Fitting Instructions and User Guide

SMART HOT WATER SOLUTIONS PRODUCT RANGE

Multipoint. Unvented point of use hot water

Amptec. Electric flow boiler

Installation and User Instructions HS10U, HS15U.

Cistern-fed water heating

SMART HOT WATER SOLUTIONS PRODUCT RANGE

MULTIPOINT 30 & 50 Litre

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

Ventilation Product range ADVANCE ECO 4 ECO 2

Combined electric boiler and domestic hot water store

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

MULTIPOINT SS H 50/80 & 100

HOTFLO 10 / 15. Fitting Instructions and User Guide

Unvented Electric Water Heater 10/15 litre Undersink

Streamline. Vented point of use hot water

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Installation and User Instructions Aquaheat Unvented Water Heaters Models: SS V 50/80 & 100

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

Express 50 Litres Installation, operation and maintenance manual

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Hand Hygiene. September 2015 EV Instantaneous Handwash

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Stored Water District Heating Interface Units. Heat Interface Units

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

2015 PRODUCT RANGE GUIDE

Unvented water heating

Megaflo eco Unvented hot water cylinders

Electromax. Combined electric boiler and domestic hot water store

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

Powerflow Unvented water heater

Cylinders & Water Heaters

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Handy No Touch Electric Handwash Fitting Instructions

Instructions for Use Installation and Servicing

Unvented Water Heating. Zircon

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

Installation and Servicing Instructions. Alpha GasSaver GS-1

Megaflo Eco Unvented Direct & Indirect Hot Water Cylinders

Megalife Vented Cistern Fed Water Heater Installation manual

Unvented Direct & Indirect Hot Water Cylinders (400L L)

ZIP AquaFlo II. Models: Direct, Indirect and Solar Compatible. Unvented cylinder water heaters

PremierPlus. and PremierPlus SystemFit. Direct and Indirect Unvented Water Heating. Unvented Water Heaters

Installation and Commissioning Manual

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Hotflo Vertical Litres Installation, operation and maintenance manual

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Handy Dri / Hair Drier

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

UNVENTED STAINLESS STEEL CYLINDERS

Unvented Direct & Indirect Hot Water Cylinders (400L L)

Megaflo Eco Unvented Direct & Indirect Solar Hot Water Cylinders

Multipoint ECO Horizontal Litres Installation, operation and maintenance manual

Installation & Technical Guide. Domestic & Commercial.

MEGAFLO HE Iss 1

Supreme 150SS, 165SS, 180SS Fitting Instructions and User Guide

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Megaflo eco. Unvented hot water cylinders

STAINLESSLITE ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

Megaflo Eco Solar PV Ready Unvented Direct & Indirect Hot Water Cylinders 170L - 300L

Megaflo Eco Slimline Unvented Direct & Indirect Hot Water Cylinders 100L - 200L

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

Regulations, Legislation and Byelaws

CI/SfB. (53.3) x. October Unvented Water Heaters. PremierPlus. Unvented Hot Water Cylinders

unistor High performance unvented stainless steel cylinder range

Exceeding the Standard

the electric heating company ELECTRIC BOILER HANDBOOK

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

IMPORTANT: PLEASE READ ALL THESE INSTRUCTIONS BEFORE COMMENCING INSTALLATION

unistor High performance unvented stainless steel cylinder range

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Wall Hung Multipoint Water Heaters Installation & Maintenance Manual

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

FASTflo. Working towards a cleaner future

Zircon Installation Manual

Plus. USER and INSTALLATION INSTRUCTIONS. 30,000-9kW for Heating and Hot Water

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

ZIP VARIPOINT II Direct unvented water heaters.

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for vented systems.

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

A Hot water revolution

Exceeding the Standard

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

EPU - WM30 EPU - WM 50 EPU - WM100

Transcription:

Multipoint Technical Data

Multipoint 10 / 15 Specification DIMENSIONS AND PERFORMANCE Model Multipoint 10 vertical Multipoint 15 vertical Multipoint 10 4.5kW vertical Multipoint 15 4.5kW vertical A - Height (mm) 572 728 572 728 B - Width (mm) 267 267 267 267 C - Depth (mm) 252 252 252 252 A B Product Code 95:050:143 95:050:144 95:050:145 95:050:146 Element Rating @ 240V / @ 240V / 4.5kW @ 240V / 4.1kW @ 230V 4.5kW @ 240V / 4.1kW @ 230V Weight (kg empty) 6.9 8.8 6.9 8.8 Weight (kg full) 16.9 23.8 16.9 23.8 Minimum Operating Pressure (bar) 0.8 0.8 0.8 0.8 Rated Pressure (bar) 6 6 6 6 Connection Size (mm) 15 15 15 15 Pressure Tested (bar) 12 12 12 12 Maximum Supply to PRV (bar) 16 16 16 16 Capacity (litres) 10 15 10 15 Factory fitted Temperature/Pressure relief valve Yes Yes Yes Yes Temperature/Pressure relief valve setting 90ºC / 7 bar 90ºC / 7 bar 90ºC / 7 bar 90ºC / 7 bar ErP rating C C C C C Measurements in mm 2 Specification advice telephone 01603 420220 or email specifier@heatraesadia.com

Multipoint 10 / 15 Installation Installation Requirements/ Limitations: National Wiring rules may contain restrictions concerning the installation of these units in bathrooms. The unit should be vertically wall mounted using the wall bracket supplied. NOTE: Ensure that the wall can support the full weight of the unit (see technical specification). DO NOT install where the unit may freeze. The Multipoint unvented water heater must be fitted with a Pressure Relief Valve. If the static supply pressure exceeds 0.41MPa (4.1 bar) a pressure reducing valve must be fitted to the cold main supply. If a pressure reducing valve is used, an expansion vessel must also be used. The unit is supplied fitted with a 0.75m 3 core 1.5mm 2 flexible cable on the models or a 0.75m 3 core 2.5mm 2 cable on the 4.5kW model. The unit can be used to supply several hot water outlets via conventional taps. It is not recommended for supplying a shower. Warranty: The water heater is under warranty for a period of five years from the data of purchase, with the exception of the immersion heater and thermal controls which are covered for a period of two years. The unit is not covered against damage by frost and the immersion heater is not covered against excessive scale build up. Approvals: Nemko and Kiwa approved. WARNING: This appliance must be earthed. It is suitable for a.c. supply only. Specification advice telephone 01603 420220 or email specifier@heatraesadia.com 3

Multipoint 30 / 50 Specification DIMENSIONS AND PERFORMANCE Model Multipoint 30 vertical Multipoint 50 vertical Multipoint 30 1kW vertical Multipoint 50 1kW vertical Multipoint 30 horiz / wall Multipoint 50 horiz / wall A - Height (mm) 788 1060 788 1060 788 1060 B - Width (mm) 370 370 370 370 370 370 C - Depth (mm) 352 352 352 352 352 352 A Product Code 95:050:150 95:050:151 95:050:152 95:050:153 95:050:154 95:050:157 Element Rating @ 240V / @ 240V / 1kW @ 240V / 0.9kW @ 230V 1kW @ 240V / 0.9kW @ 230V @ 240V / @ 240V / Weight (kg empty) 12.5 19.3 12.5 19.3 12.5 19.3 Weight (kg full) 42.5 69.3 42.5 69.3 42.5 69.3 Minimum Operating Pressure (bar) 0.8 0.8 0.8 0.8 0.8 0.8 Rated Pressure (bar) 6 6 6 6 6 6 Connection Size (mm) 15 15 15 15 15 15 B Pressure Tested (bar) 12 12 12 12 12 12 Maximum Supply to PRV (bar) 16 16 16 16 16 16 Capacity (litres) 30 50 30 50 30 50 Factory fitted Temperature/Pressure relief valve Yes Yes Yes Yes Yes Yes B Temperature/Pressure relief valve setting 90ºC / 7 bar 90ºC / 7 bar 90ºC / 7 bar 90ºC / 7 bar 90ºC / 7 bar 90ºC / 7 bar ErP rating D D D E D D A C Measurements in mm 4 Specification advice telephone 01603 420220 or email specifier@heatraesadia.com

Multipoint 30 / 50 Installation Components: Expansion vessel ¾ BSP male, precharged pressure 0.35 MPa (3.5 bar) c/w wall mounting bracket. Combined Pressure Reducing Valve/ Strainer ½ BSP female, factory set at 0.35MPa (3.5bar). Single Check Valve 15mm x 15mm compression. Pressure (expansion) Relief Valve ½ BSP male inlet, ½ BSP female discharge factory set at 0.6MPa (6 bar). Tundish ½ BSP male inlet, ¾ BSP female outlet. Wall mounting bracket set. Self-adhesive Levelling Feet (2 off) (Vertical models only). Moulded plastic spacer (Vertical models only). Installation Requirements: The Multipoint is factory fitted with a temperature/pressure relief valve. The factory fitted temperature/pressure relief valve must not be removed, blocked or restricted in any way. Expansion must be accommodated within the system. NOTE: Ensure that the wall can support the full weight of the unit (see Technical Specifications) and that there are no hidden services below the surface of the wall. DO NOT install where the unit may freeze. The expansion vessel should be supported on its own wall bracket, do not rely on the pipework alone to support it. The water connections to the unit are 15mm diameter copper tubes suitable for compression fittings. A drain cock must be fitted below the heater in the inlet pipework. It must be sited between the heater and the Check Valve. The unit is supplied fitted with a 1.0m 3 core 1.5mm 2 flexible cable. The electricity supply should be fused 13 Amp for a model and 5 Amp for a 1kW model and be via a double pole isolating switch with a contact separation of at least 3mm in both poles. Warranty: This water heater is under warranty for a period of five years from the date of purchase with the exception of the element and thermal controls which are covered for a period of two years. The unit is not covered against damage by frost and the immersion heater is not covered against excessive scale build up. Approvals: Multipoint 30 / 50 Vertical BEAB and Kiwa approved. Multipoint 30 / 50 Horizontal BEAB approved. Specification advice telephone 01603 420220 or email specifier@heatraesadia.com 5

Multipoint 75 / 100 Specification DIMENSIONS AND PERFORMANCE Model Multipoint 75 vertical Multipoint 75 6kW vertical Multipoint 100 vertical Multipoint 100 6kW vertical A - Height (mm) 1055 1055 1213 1213 B - Width (mm) 729 729 729 729 C - Depth (mm) 430 430 430 430 A Product Code 95:050:170 95:050:171 95:050:172 95:050:173 Element Rating 3 6 3 6 Weight (kg empty) 38 38 50 50 Weight (kg full) 113 113 150 150 Minimum Operating Pressure (bar) 0.8 0.8 0.8 0.8 Rated Pressure (bar) 6 6 6 6 Connection Size (mm) 15 15 15 15 Pressure Tested (bar) 12 12 12 12 Maximum Supply to PRV (bar) 16 16 16 16 Capacity (litres) 75 75 100 100 Factory fitted Temperature/Pressure relief valve Yes Yes Yes Yes Temperature/Pressure relief valve setting 90ºC / 7 bar 90ºC / 7 bar 90ºC / 7 bar 90ºC / 7 bar ErP rating D D D D B C Measurements in mm 6 Specification advice telephone 01603 420220 or email specifier@heatraesadia.com

Multipoint 75 / 100 Installation Components: Combined pressure reducing valve and strainer. Tundish. Mounting brackets. Mounting bracket fixing bolts (x6). Installation Requirements: The Multipoint is factory fitted with two Temperature/Pressure Relief Valves which must not be removed, blocked or restricted in any way. Expansion must be accommodated within the system. The 75/100 incorporates an expansion vessel and check valve for this purpose. The Multipoint must be vertically wall mounted using the bracket provided. The water connections must always be at the bottom of the unit. The water connections to the unit are 15mm diameter copper tubes suitable for compression fittings. The unit is supplied fitted with a 2.0m 3 core 1.5mm 2 flexible cable ( models) or 2.0m 3 core 4.0mm 2 flexible cable (6kW models). The electricity supply should be fused at 13 Amp for a model and 32 Amp for a 6kW model and be via a double pole isolating switch with a contact separation of at least 3mm in both poles. Warranty: This water heater is under warranty for a period of five years from the date of purchase with the exception of the element and thermal controls which are covered for a period of two years. Approvals: Kiwa approved. Ensure that the wall can support the full weight of the unit and that there are no hidden services below the wall. To make the installation easier, the Multipoint 75/100 is supplied with an integral non-return valve, expansion vessel and pressure relief valve. Specification advice telephone 01603 420220 or email specifier@heatraesadia.com 7

Specification DIMENSIONS AND PERFORMANCE A Model 50 Horizontal 80 Horizontal 100 Horizontal 50 Vertical 80 Vertical 100 Vertical A - Height (mm) 700 958 1146 705 963 1151 B - Width (mm) 451 451 451 451 451 451 C - Depth (mm) 472 472 472 472 472 472 B B A Product Code 95:050:175 95:050:177 95:050:179 95:050:181 95:050:183 95:050:185 Element Rating @ 240V / @ 240V / @ 240V / @ 240V / @ 240V / @ 240V / Weight (kg empty) 18 24 30 18 24 30 Weight (kg full) 68 104 130 68 104 130 Minimum Operating Pressure (bar) 1 1 1 1 1 1 Rated Pressure (bar) 6 6 6 6 6 6 Connection Size (mm) 22 22 22 22 22 22 Pressure Tested (bar) 16 16 16 16 16 16 Maximum Supply to PRV (bar) 16 16 16 16 16 16 Capacity (litres) 50 80 100 50 80 100 Heat up times (mins)* 49 76 93 49 81 104 Recovery times (mins)** 36 51 58 32 56 73 Factory fitted Temperature/Pressure relief valve Yes Yes Yes Yes Yes Yes Temperature/Pressure relief valve setting 90ºC / 7 bar 90ºC / 7 bar 90ºC / 7 bar 90ºC / 7 bar 90ºC / 7 bar 90ºC / 7 bar ErP rating D D D D D D *Heat up times are based on heating from 20ºC through 45ºC temperature rise. **Recovery times are based on heating 70% of capacity through 45ºC. C Measurements in mm 8 Specification advice telephone 01603 420220 or email specifier@heatraesadia.com

Installation Components: Expansion vessel ¾" BSP male, precharge pressure 3.5bar. Expansion vessel wall mounting bracket. Pressure reducing valve 3.5bar, 22mm x 22mm compression. Single check valve 22mm x 22mm compression. Installation Requirements: The unvented water heater is factory fitted with a Temperature/Pressure Relief Valve which must not be removed, blocked or restricted in any way. Expansion MUST be accommodated within the system. The expansion vessel & check valve provided in the installation kit must be installed and will fulfil this function. Warranty: The is under warranty against faulty materials and manufacture for a period of 15 years for the inner stainless steel hot water cylinder, with all other components covered for 2 years. The unit is not covered against damage by frost and the immersion heater is not covered against excessive scale build-up. Approvals: Nemko, BEAB and Kiwa approved. Pressure Relief Valve ½" BSP x ½" BSP female, factory set at 6 bar. Tundish, 22mm x 15mm compression. ¾" compression nuts (x2). Ensure that the wall can support the full weight of the unit and that there are no hidden services below the surface of the wall. DO NOT install where the unit may freeze. Copper olive, 22mm (x2). Mounting brackets (x4). DO NOT install in direct sunlight or where the unit is open to the elements. For ease of installation is supplied with a non-return valve, expansion vessel and pressure relief valve. Specification advice telephone 01603 420220 or email specifier@heatraesadia.com 9

ErP Technical data Multipoint 10 / 15 Supplier s name or trade mark Multipoint Supplier s model identifier 10L () 10L (4.5kW) 15L () 15L (4.5kW) Storage volume V in litres 10 10 15 15 Mixed water at 40 C V40 in litres 19 19 27 27 The declared load profile XXS XXS XXS XXS The water heating energy efficiency class of the model C C C C The water heating energy efficiency in % 30.9 30.9 29.6 29.6 The annual electricity consumption in kwh 596 596 622 622 Daily fuel consumption Q fuel in kwh 2.900 2.900 3.050 3.050 The thermostat temperature settings of the water heater, as placed on the market by the supplier 60 C 60 C 60 C 60 C Multipoint 30 / 50 Supplier s name or trade mark Multipoint Supplier s model identifier 30V 50V 30V 1kW 50V 1kW 30H 50H Storage volume V in litres 30.0 50.0 30.0 50.0 30 50 Mixed water at 40 C V40 in litres 46 86 46 79 39 61 The declared load profile S S M M S M The water heating energy efficiency class of the model D D D E D D The water heating energy efficiency in % 30.4 33.9 34.7 30.4 29.3 34.7 The annual electricity consumption in kwh 606 1516 608 1481 629 1482 Daily fuel consumption Q fuel in kwh 2.960 7.220 2.970 7.020 3.090 7.020 The thermostat temperature settings of the water heater, as placed on the market by the supplier 60 C 60 C 60 C 60 C 60 C 60 C 10 Specification advice telephone 01603 420220 or email specifier@heatraesadia.com

ErP Technical data Multipoint 75 / 100 Supplier s name or trade mark Multipoint 75/100 Supplier s model identifier 75/3 75/6 100/3 100/6 Storage volume V in litres 75 75 100 100 Mixed water at 40 C V40 in litres 129 125 162 162 The declared load profile M M L L The water heating energy efficiency class of the model D D D D The water heating energy efficiency in % 33.0 33.2 35.6 35.6 The annual electricity consumption in kwh 1555 1543 2878 2878 Daily fuel consumption Q fuel in kwh 7.450 7.380 13.540 13.540 The thermostat temperature settings of the water heater, as placed on the market by the supplier 60 C 60 C 60 C 60 C Supplier s name or trade mark Multipoint Supplier s model identifier 50L V 50L H 80L V 80L H 100L V 100L H Storage volume V in litres 50 50 80 80 100 100 Mixed water at 40 C V40 in litres 77 82 126 12 157 159 The declared load profile M M M M L L The water heating energy efficiency class of the model D D D D D D The water heating energy efficiency in % 34.6 34.3 34.1 34.5 35.7 34.5 The annual electricity consumption in kwh 1484 1497 1505 1486 2866 2968 Daily fuel consumption Q fuel in kwh 7.030 7.110 7.15 7.04 13.470 14.070 The thermostat temperature settings of the water heater, as placed on the market by the supplier 60 C 60 C 60 C 60 C 60 C 60 C Specification advice telephone 01603 420220 or email specifier@heatraesadia.com 11

UNVENTED POINT-OF-USE HOT WATER SPECIFICATION ADVICE HOTLINE t 01603 420220 e specifier@heatraesadia.com AFTER SALES SERVICE t 0344 871 1535 e heatraesadiaservice@heateam.co.uk w heatraesadia.com MADE IN THE UK 15 YEAR CYLINDER WARRANTY 15 5 YEAR INNER CONTAINER WARRANTY 5 Our nationwide network of Customer Support engineers Heatrae Sadia has its very own dedicated nationwide network of highly trained customer support engineers so you can have peace of mind that we re always here to help. PRODUCT RANGE Full specification details on all our products are available to download from our website. To support our corporate responsibility and sustainability charters and reduce our printed material, we encourage you to download product brochures from our website. In designing these files we have taken into account the need to access data on screen. If you would like to receive a printed copy of our full product catalogue please call our literature hotline on 01603 420127. Heatrae Sadia may introduce modifications to their products from time to time. Consequently, the details given in this brochure are subject to alteration without notice. Please follow us online: Please recycle this product once you have finished with it. PN XXXXXX Issue 1 BJN 204344-106 Heatrae Sadia 2015