Ground Breaking Innovation

Similar documents
WIREMOLD 8" Evolution Series Poke-Thru Devices

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures

Evolution Series The most innovative poke-thru devices in the market

Wiremold. Evolution Series Boxes now available for ceilings. Evolution Series Ceiling Boxes

Arrow Hart hospital grade self-test GFCI receptacles

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY

AF/GF dual-purpose receptacles

Hardscape & Landscape

(Refer Slide Time: 03:23)

Introducing a revolutionary new line of 15 and 20 amp devices engineered for fast and easy installation

Gfci Self Test Duplex 20A 125V WH

Road Soil. Curtis F. Berthelot Ph.D., P.Eng. Department of Civil Engineering. Road Soil Introduction

-AIHL NOISE UNIFIED SOIL CLASSIFICATION SYSTEM. Aqx. R CORPS OF ENGINEERS, U. S. ARMY APPENDIX A

Subsoil conditions are examined using test borings, provided by soil engineer (geotechnical).

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Afci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

Arrow Hart specification grade GFCI receptacles

TAILORED S PECTRUM. Commercial Grow Luminaire SQRT670CX1 INSTRUCTION MANUAL

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

Product Code for Zoom: KPLZML1RGBW Product Code for Wall Wash: KPLWWL2RGBW

Afci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions

Installation Instructions

Options for Diesel Fire Pump Controllers

AFCI. RECEPTACLEFAQs. What is an arc fault? What causes arc faults?

Organization Summary and Directory. Standards Organization Summary and Directory Overview. Technical Information: Standards

Wireless DC Voltage Detector

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

Specification Grade Straight Blade Receptacles. Quality solutions that provide reliable connectivity in all applications

DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

IMPORTANT INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS. Electric Wall Panel. Owner s Manual & Installation Instructions L

APW-VAP-150P High Pressure Cleaner Operator Manual

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

EMERGENCY EYEWASH AND SHOWER TECHNOLOGY

Crouse-Hinds Enclosures. High performance, high reliability enclosures for global applications

DRIVABLE GRASS. Permeable, Flexible and Plantable Concrete Pavement System

The most complete line of proven safety solutions.

CUTTING EDGE TURF PRODUCTS

SECTION (16140) - WIRING DEVICES

SECTION AUTOMATIC TRANSFER SWITCHES

Wireless Water Detection Sensors General Description Features of Monnit ALTA Sensors Water Detection Principle of Operation

NEMA Enclosures for Electrical Equipment (1000 Volts Maximum)

VDC. Wireless AC Voltage Detection Sensor. The Leader in Low-Cost, Remote Monitoring Solutions. General Description. Monnit Sensor Core Specifications

VDC. The Leading Enterprise Internet of Things Solution. Wireless DC Voltage Detection Sensors (0-50 VDC) General Description

POU Water Dispenser User Manual

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

SECTION CUSTOM FABRICATED LABORATORY EQUIPMENT. This section specifies necropsy // dissecting tables // and // animalcage

TotalPac X Single interlock SUREFIRE system

Installation Instructions Air Pump

Carlon Floor Boxes. In this section... Carlon. Floor Boxes

30 Misting/Oscillating Fan Model Number 01030

Schneider Electric ibusway for Data Center: Schneider Electric Powerbus Plug-In Busway

Introducing Solar Identification Labels

Installation Instructions for. OmniFount

Wireless Light Detection Sensor

BorAL. PAvErS Build something great. commercial pavers BUILD A TRADITION IN YOUR COMMUNITY WITH BORAL PAVERS.

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

SUPPLEMENTARY INSTRUCTIONS

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

3099-2E. Technical Information

PANELBOARD PROTECTION ON A GLOBAL SCALE

Installation Instructions Wall Ovens

Wireless Duct Temperature Sensor

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

Eseta. Architectural LED Wall Sconce. Area lighting for outdoor wall-mounted applications.

Type VSA Suspended Wet Pit Sewage Pumps BULLETIN 228E-1 September 2014

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

Electric Submersible Pumps

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

MORE PROTECTION. MORE FUNCTIONALITY. IN MORE ENVIRONMENTS.

commercial-type cabling and connectivity products into the industrial landscape.

The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. General Description. Features of Monnit ALTA Sensors

Operating Instructions

The Leading Enterprise Internet of Things Solution. Wireless AC Voltage Detection Sensors ( VAC) VOLTAGE DETECT. General Description

SELF-CONTAINED POWER MISTER

Fiber Distribution Box

Installation Instructions

Applications and Features

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

CLE SERIES Fluid heating for emergency eyewash stations

Model K 520 M Part No

BEFORE OPERATING THE MACHINE: WARNING

Wireless Thermocouple Sensor

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization

The Leading Enterprise Internet of Things Solution. Wireless Dry Contact Sensors. General Description. Features of Monnit ALTA Sensors

User s Manual. For the SHORE POWER CONNECTION MONITOR MODEL 9151

The Leading Enterprise Internet of Things Solution. Wireless Open / Closed Sensors OPEN / CLOSED. Features of Monnit ALTA Sensors. General Description

Selecting an Electrical Enclosure

The Leading Enterprise Internet of Things Solution. Wireless Duct Temperature Sensors. General Description. Features of Monnit ALTA Sensors

Smart Products. Ingenious Solutions.

Your Single Source Partner with Watts for a Comprehensive Suite of Innovative Water Solutions

Bottled Water Dispenser User Manual

Liberty Premium 8. User Instructions

K 3.97 M. Specifications or visit our website: In USA call: Part No

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

INSTALLATION MANUAL. PP1 Ozone System Designed for use within pool skimmer

E R O S I O N C O N T R O L

AIR OPERATED CLUTCH & BRAKE BLEEDING KIT. MODEL NO: CHT637 Part No: OPERATING & MAINTENANCE INSTRUCTIONS GC01/12

Transcription:

, part of the Outdoor Power offering from Legrand Ground Breaking Innovation As the popularity of outdoor activities grows, so does the demand for connected outdoor spaces that include power, communications and A/V. The from Legrand is the first product designed with power and safety in mind. It s the first in-ground product on the market that will deliver permanent power and uses a UL50E Type 6P rated wiring enclosure and has been tested and evaluated by Underwriters Laboratories, Inc. for safe operation year round. The is designed to handle the requirements of the outdoor space while blending into the landscape. It s perfect for spaces such as: outdoor retail shopping centers, corporate campuses, amusement parks, sports fields, hospitality, or any outdoor space power is required. Features & Benefits Air Pocket Design - This innovative design traps and maintains an air pocket protecting the devices, plugs and connections from water, snow, and ice. Allow for safer operation year round. Outdoor-Rated Construction UV and chemical-resistant F1 rated nonmetallic materials, allows the box to hold up for years to come. Three Durable, Premium Finishes Outdoor-rated finishes to complement your space design. Choose from black, brown, or gray. Holds up to 5000 lbs - Has an ANSI/SCTE 77 Tier 5 rating and can hold up to 5,000 lbs of load allowing for the occasional tractor or non-deliberate vehicular traffic. Anti-Float Clips Prevents the cover from floating up when flooded. This preserves the air pocket and ensures safe operation. Smart egress door Egress door auto adjusts to the size of cable, as well as locking in the closed position when not in use. Prevents cable damage and maintains a safer user experience. Secure Includes tamper-resistant lock to prevent unauthorized access. Service feed flexibility Each box comes with two (2) locations that will accept up to 1 1/4" trade size nonmetallic conduit, allowing for services to feed the box as well as to daisy chain to other boxes. Modular design - Boxes are designed to interlock allowing endless number of boxes in the same location. Provides service separation, everything in one location, and easier installation. Flush to the finished ground - The buried box can be made flush with any surface, grass, walkways (brick, pavers, concrete, etc). Reduces trip hazards and allows it to blend in with its surroundings. ADA compliant Meets all specifications for ADA guidelines. culus listed to UL50E Type 6P and IP68 requirements while in use - Tested and listed by Underwriters Laboratories, Inc. to UL2996 and ULC/ORD-C2996:2017 for use in the ground in all weather conditions. Vertical Markets Commercial Hospitality Education Parks Entertainment Healthcare Retail Transit Compliance culus Listed, File Number E486738. Guide QCNL/QCNL7. es (Power Applications) are UL Listed to meet UL50E Type 6P and IP68 requirements. es (Low Voltage Applications) are UL Listed to meet UL50E Type 4X and IP65 requirements. ED1782R3 Updated November 2017 For latest specs visit www.legrand.us/wiremold

Installation Considerations Determine location to install the Ground Box: The location must be in a well drained area, away from inlets and outfalls. Do not install Box at low points or in areas prone to accumulate standing water. Do not install Box in locations where it will be subject to deliberate vehicular traffic. Box is rated for occasional non-deliberate vehicular traffic with a maximum 5,000 lb (22.2 kn) design load (ANSI/SCTE 77 Tier 5). Box should only be installed in locations where the grade is within 1% of level. Box should be installed in sidewalks only where the grade is less than 2% in all directions. Box installation in locations where the seasonally high water table is less than 3 feet (600mm) below finished grade is not recommended. Consultation of a licensed professional engineer knowledgeable of local soils is recommended to determine if unsuitable or poor soils may be encountered at the intended Box location. Do not install Box on unsuitable soils. Unsuitable soils are those with unsatisfactory drainage characteristics and high volume change potential. Unsuitable soils are defined herein as USCS soil groups OL, OH, and PT (organic silts, organic clays, and peat). Installation of Box on poor soils is not recommended without additional drainage improvements. A method for improving drainage and minimizing the potential for heave in frost-susceptible and other poor soils is presented in the product installation instructions. Poor soils are those with poor drainage characteristics. For warm and cold climates, poor soils are defined herein as USCS soil groups ML, MH, CL, and CH (inorganic silts and inorganic clays). Additionally, for cold climates poor soils include USCS soil groups GC and SC (clayey gravels and clayey sands). Poor soils are not a concern for un-irrigated locations where the average annual precipitation is less than 30 inches (762mm). Do not install Box in permafrost areas. Box should not be installed in locations where bedrock is less than 3 feet (600mm) below finished grade. Environmental Code Ratings Type 6P Type 4X Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts to provide a degree of protection against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, hose directed water, and the entry of water during prolonged submersion at a limited depth); that provides an increased level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure. Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose-directed water); that provides an increased level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure. The IP Code is an International Protection Marking per IEC standard 60529. IP 68 Enclosure is dust tight. No ingress of dust; complete protection against contact. Enclosure is protected in immersion beyond 1 meter. The equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer. Normally, this will mean that the equipment is hermetically sealed. However, with certain types of equipment, it can mean that water can enter but only in such a manner that it produces no harmful effects. IP 65 Enclosure is dust tight. No ingress of dust; complete protection against contact. Enclosure is protected from water jets. Water projected by a nozzle (6.3mm) against enclosure from any direction shall have no harmful effects. Glossary of Terms: USCS Unified Soil Classification System OL Organic silts and organic silty clays of low plasticity OH Organic clays of medium to high plasticity, organic silts PT Peat and other highly organic silts ML Inorganic silts and very fine sands, rock flour, clayey silts or fine sands with slight plasticity MH Inorganic silts, micaceous or diatomaceous fine sandy or silty soils, elastic silts CL Inorganic clays of low to medium plasticity, gravely clays, sandy clays, silty clays, lean clays CH Inorganic clays of high plasticity, fat clays GC Clayey gravels, gravel-sand-clay mixtures SC Clayey sands, sand-clay mixtures ED1782R3 Updated November 2017 For latest specs visit www.legrand.us/wiremold 2

XB814 Exterior Ground Box Single service 2-gang nonmetallic ground box. The box is made from f1 rated nonmetallic material and has been designed to withstand harsh outdoor environments. The box can accept up to (2) 1 1/4" trade size PVC conduit feeds. Boxes are designed to be installed separately or ganged together, for greater capacity and flexibility. Works with XB814 cover assembly (sold separately). These boxes are perfect for grass, sidewalks, patio, or any other location where permanent power is needed. TOP 16 1/8" (410mm) 8 1/8" (206mm) 7/8" (22.2mm) FRONT 14 1/8" (359mm) SIDE 10 3/4" (273mm) Tab 6" (152mm) Hook 8 3/4" (222mm) BOTTOM 13 7/8" (352mm) 7 1/2" (191mm) 3/4" - 1 1/4" Trade Size Feed Locations ED1782R3 Updated November 2017 For latest specs visit www.legrand.us/wiremold 3

XB814C520BN XB814C520BK XB814C520GY Exterior Box Cover Assembly 5-20R Exterior box cover assembly prewired with (2) 20A weather resistant duplex receptacles. Both duplex receptacles are wired together on a single circuit. Available in brown (XB814C520BN), black (XB814C520BK), or gray (XB814C520GY). When used in conjunction with the ground box body (XB814) the entire unit has a UL50E Type 6P & IP68 rating in outdoor locations. CAUTION: All ground box electrical circuits must be protected by a Ground Fault Circuit Interrupter upstream from the ground box. NOTE: Cover must be closed while in use. Use only molded plug and cord assemblies that are rated for outdoor use. NOTE: Maximum length of plug allowed at end of cord is 3" (76mm). TOP 11 1/8" (283mm) INSIDE VIEW 7 3/8" (187mm) Components Included: Cover Flange 1 7/8" (48mm) Receptacle, NEMA 5-20R Cover Body Textured Surface Plate Egress Door Handle SOOW Cord NEMA 6P Rated Wiring Enclosure 2 20A Duplex Weather Resistant Receptacles FRONT 6 5/8" (168mm) 14" (356mm) BACK 3/4" (19.1mm) 8" (203mm) Tamper-Resistant Key & Lock NOTE: Lock Nut Tool (XBLNT) sold separately. 19 5/8" (498mm) 2 1/4" (57mm) 5 5/8" (143mm) 4 5/8" (117mm) ED1782R3 Updated November 2017 For latest specs visit www.legrand.us/wiremold 4

XB814C520C2BN XB814C520C2BK XB814C520C2GY Exterior Box Cover Assembly 5-20R (Two-Circuit) Exterior box cover assembly prewired with (2) 20A weather resistant duplex receptacles. Receptacles are wired on separate circuits with a shared neutral. NOTE: Installation requires double pole GFCI circuit breaker. Available in brown (XB814C520C2BN), black (XB814C520C2BK), or gray (XB814C520C2GY). When used in conjunction with the ground box body (XB814) the entire unit has a UL50E Type 6P & IP68 rating in outdoor locations. CAUTION: All ground box electrical circuits must be protected by a Ground Fault Circuit Interrupter upstream from the ground box. NOTE: Cover must be closed while in use. Use only molded plug and cord assemblies that are rated for outdoor use. NOTE: Maximum length of plug allowed at end of cord is 3" (76mm). TOP 11 1/8" (283mm) INSIDE VIEW 7 3/8" (187mm) Components Included: Cover Flange Cover Body 1 7/8" (48mm) Receptacle, NEMA 5-20R Textured Surface Plate Egress Door Handle SOOW Cord NEMA 6P Rated Wiring Enclosure 2 20A Duplex Weather Resistant Receptacles Tamper-Resistant Key & Lock FRONT 6 5/8" (168mm) 14" (356mm) BACK 3/4" (19.1mm) 8" (203mm) NOTE: Lock Nut Tool (XBLNT) sold separately. 19 5/8" (498mm) 2 1/4" (57mm) 5 5/8" (143mm) 4 5/8" (117mm) ED1782R3 Updated November 2017 For latest specs visit www.legrand.us/wiremold 5

XB814CL530BN XB814CL530BK XB814CL530GY Exterior Box Cover Assembly L5-30R Exterior box cover assembly prewired with (1) 30A L5-30R 120V, corrosion-resistant receptacle. Available in brown (XB814CL530BN), black (XB814CL530BK), or gray (XB814CL530GY). When used in conjunction with the ground box body (XB814) the entire unit has a UL50E Type 6P & IP68 rating in outdoor locations. CAUTION: All ground box electrical circuits must be protected by a Ground Fault Circuit Interrupter upstream from the ground box. NOTE: Cover must be closed while in use. Use only molded plug and cord assemblies that are rated for outdoor use. NOTE: Maximum length of plug allowed at end of cord is 3" (76mm). TOP 11 1/8" (283mm) INSIDE VIEW 7 3/8" (187mm) Components Included: Cover Flange 1 7/8" (48mm) Receptacle, NEMA L5-30R Cover Body Textured Surface Plate Egress Door Handle SOOW Cord NEMA 6P Rated Wiring Enclosure L5-30R 30A Locking Corrosion Resistant Receptacle FRONT 6 5/8" (168mm) 14" (356mm) BACK 3/4" (19.1mm) 8" (203mm) Tamper-Resistant Key & Lock NOTE: Lock Nut Tool (XBLNT) sold separately. 19 5/8" (498mm) 2 1/4" (57mm) 5 5/8" (143mm) 4 5/8" (117mm) ED1782R3 Updated November 2017 For latest specs visit www.legrand.us/wiremold 6

XB814CL630BN XB814CL630BK XB814CL630GY Exterior Box Cover Assembly L6-30R Exterior box cover assembly prewired with (1) 30A L6-30R, 240 V corrosion-resistant receptacle. Available in brown (XB814CL630BN), black (XB814CL630BK), or gray (XB814CL630GY). When used in conjunction with the ground box body (XB814) the entire unit has a UL50E Type 6P & IP68 rating in outdoor locations. CAUTION: All ground box electrical circuits must be protected by a Ground Fault Circuit Interrupter upstream from the ground box. NOTE: Cover must be closed while in use. Use only molded plug and cord assemblies that are rated for outdoor use. NOTE: Maximum length of plug allowed at end of cord is 3" (76mm). TOP 11 1/8" (283mm) INSIDE VIEW 7 3/8" (187mm) Components Included: Cover Flange 1 7/8" (48mm) Receptacle, NEMA L6-30R Cover Body Textured Surface Plate Egress Door Handle SOOW Cord NEMA 6P Rated Wiring Enclosure FRONT 14" (356mm) BACK 3/4" (19.1mm) 8" (203mm) L6-30R 30A Locking Corrosion Resistant Receptacle 6 5/8" (168mm) Tamper-Resistant Key & Lock NOTE: Lock Nut Tool (XBLNT) sold separately. 19 5/8" (498mm) 2 1/4" (57mm) 5 5/8" (143mm) 4 5/8" (117mm) ED1782R3 Updated November 2017 For latest specs visit www.legrand.us/wiremold 7

XB814CLVBN XB814CLVBK XB814CLVGY Exterior Box Cover Assembly Low Voltage Exterior box low voltage cover assembly, designed to accept up to 12 communication ports or 8 Legrand AVIP devices. Available in brown (XB814CLVBN), black (XB814CLVBK), or gray (XB814CLVGY). When used in conjunction with the ground box body (XB814) the entire unit has a UL50E Type 4X & IP65 rating in outdoor locations. NOTE: Cover must be closed while in use. Use only cables that are rated for outdoor use. NOTE: Maximum length of connector allowed at end of cable is 2" (51mm). TOP 11 1/8" (283mm) INSIDE VIEWS For AVIP Devices 7 3/8" (187mm) Components Included: Cover Flange Cover Body 1 7/8" (48mm) For MAB Devices Textured Surface Plate Egress Door Handle 1" Trade Size Cable Chase NEMA 4X Rated Wiring Enclosure 8-Port AVIP Device Mounting Plate 12-Port Communications Device Plate Tamper-Resistant Key & Lock SIDE 14" (356mm) FRONT 3/4" (19.1mm) 8" (203mm) NOTE: Lock Nut Tool (XBLNT) sold separately. 6 5/8" (168mm) 19 5/8" (498mm) Corrugated Conduit 2 1/4" (57mm) 5 5/8" (143mm) 4 5/8" (117mm) ED1782R3 Updated November 2017 For latest specs visit www.legrand.us/wiremold 8

Accessories Ordering Information XB814CPBN XB814CPBK XB814CPGY Exterior Box Cover Plate Kit Replacement cover plate. Comes complete with a new handle and all of the mounting hardware required. Available in brown (XB814CPBN), black (XB814CPBK), or gray (XB814CPGY). XB814SP Replacement Egress Door Spring Pin Set Locks the egress door in the closed position when cover is closed. XB814ED Replacement Egress Door Kit Replacement door can be changed out if the door ever wears out or becomes damaged. XBLNT Exterior Box Locknut Tool Exterior Box locknut wrench. Used to tighten the locknut on the junction box. Sold Separately., exterior view, view installed with bricks, and a cross-sectional view of a Ground Box installation. ED1782R3 Updated November 2017 For latest specs visit www.legrand.us/wiremold 9

ED1782R3 Updated November 2017 For latest specs visit www.legrand.us/wiremold 10

ED1782R3 Updated November 2017 For latest specs visit www.legrand.us/wiremold 11

NOTE: All brand and product names referenced in this document are registered trademarks or trademarks of their respective holders. NOTE: The paper used to print this document is an environmentally responsible paper with 10% post consumer waste, with FSC and SFI Chain of Custody certifications, Lacey Act complaint. 100% of the electricity used to manufacture Flo sheets is generated with Green-e certified renewable energy. Legrand, North America 60 Woodlawn Street West Hartford, CT 06110 1.877.BY.LEGRAND (295.3472) www.legrand.us Canada 905.738.9195 www.legrand.ca FOLLOW US ED1782R3 Updated November 2017 For latest specs visit www.legrand.us/wiremold