MARVAIR COMPAC AIR CONDITIONERS MODELS AVP EXPLODED VIEW PARTS ID

Similar documents
MARVAIR CLASSIC HEAT PUMPS MODELS AVP HP EXPLODED VIEW PARTS ID

MARVAIR MODPAC II AIR CONDITIONERS MODELS AVP EXPLODED VIEW PARTS ID

MARVAIR COMPAC AIR CONDITIONERS MODELS AVP72AC AND AVPA72AC EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS)

MARVAIR MODPAC TM AIR CONDITIONERS MODELS AVPA EXPLODED VIEW PARTS ID

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)

REPLACEMENT PARTS MANUAL

MARVAIR SCHOLAR III HEAT PUMPS & AIR CONDITIONERS MODELS VAIA & VAISA EXPLODED VIEW PARTS ID

DDYZ SERIES - 13 SEER SINGLE PACKAGED GAS/ELECTRIC AIR CONDITIONER (R-410A, STYLE A,B)

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL

CME650 SERVICE PARTS

REPLACEMENT PARTS LIST

SCE170 SERVICE PARTS

REPLACEMENT PARTS MANUAL

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

Spare Parts Catalogue MV1006

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 Includes 50Hz. Units

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0806, ICE1006 Includes 50Hz. and 3 Phase Units

REPLACEMENT PARTS LIST

For more Parts Information:

SERVICE MANUAL FOR 6633 SERIES PACKAGE AIR CONDITIONER

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Assembly

Repair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB. When requesting service or ordering parts, always provide the following information:

Installation and Maintenance Manual Please retain this manual for future reference.

For more Parts Information:

REPAIR PARTS. PTC073G Package Terminal Air Conditioner. This manual is to be used by qualified technicians only. This manual replaces RP-A5067.

SERVICE PARTS MANUAL. The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

NM952 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor...

Nordic Model CCU0150, 0220 Service Parts Manual (Includes 50Hz. Units)

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

REPLACEMENT PARTS MANUAL

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Portable Vertical Air-Conditioning and Heating Systems

SERVICE PARTS MANUAL MODEL-ICE1405, ICE1406 and ICE1407 Version 3 Includes 50Hz.and 3 phase Units

SERVICE PARTS MANUAL MODEL-ICE1806 and ICE1807 Version 3 MODEL-ICE2106 and ICE2107 Version 3

SERVICE PARTS MANUAL MODELS-ICE1806 and ICE1807 Version 4-5 MODELS-ICE2106 and ICE2107 Version 4-5 Includes 3 Phase Units

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

Parts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com

M50SL / M75SL Parts Manual

REPLACEMENT PARTS LIST Dual Fuel Gas Heat Pump DF6SF Series & DF6SF "A" Series 15 SEER Models

Repair Parts List REFRIGERATOR MODEL NUMBER LTF2112ARB. When requesting service or ordering parts, always provide the following information:

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

CMS1402 SERVICE PARTS

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

SERVICE PARTS MANUAL GEM0650A/W/R,GEM0956A/W/R and GEM1256A/W/R GEM0655 Air

CME1056 Service Parts. Table of Contents

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com

FM1500 SERVICE PARTS

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Service Parts for models UF424 and UN324

REPLACEMENT PARTS MANUAL

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

SERVICE MANUAL FOR 6795B,C,D SERIES PACKAGED AIR CONDITIONERS

Advance Release September 2009

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

Commercial High-Efficiency Condensing Units

PRE-WIRED FOR OPTIONAL HEAT PACKAGE

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

RSG16**S1M. Split System Air Conditioner 16 SEER

Product Data. Fig. 1 - Unit 50VR -A

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)

NM1850 SERVICE PARTS

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

ICEU 36 SPARE PARTS LIST REV. 07/2016

COMPACT DRYER GDZ5-1 Training Presentation

Spare Parts Catalogue AC176

Parts List. Modular Crescent Cuber. Models KM-1100MAJ, MWJ, MRJ. hoshizakiamerica.com

50TM TFF COMBINATION HEATING/COOLING UNITS

WALL-MOUNT HEAT PUMPS - (60HZ)

Operation Manual and Parts Directory

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

REPAIR PARTS. GSZ14 R-410A Remote Heat Pumps GSZ140181AA GSZ140241AA GSZ140301AA GSZ140361AA GSZ140421AA GSZ140481AA GSZ140601AA

50TM COMBINATION HEATING/COOLING UNITS

CABINET PARTS For Model: KSSS48QJX00 (Stainless Steel)

C13-Series Engineering Guide

Replacement Parts List For Models COS-20G

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts.

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

CHP/CCP CEILING MOUNTED AIR HANDLER (ALL CAPACITIES) BACK TO INDEX ITEM QTY. DESCRIPTION

Shelleybasic. Parts List For Replacements Parts Only Shelleybasic Is No Longer In Production As Of April 2016

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

Replacement Parts List

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Hoshizaki America, Inc.

RP8.1Y (ERRATA 1) (202) 2 of 8

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

Replacement Parts List

ComPac I and ComPac II Air Conditioner Product Manual

Air Conditioners (Outdoor)

Transcription:

EXTERIOR SHEET METAL (OUTER PANELS) 1 Panel, Back (Galvanized) M/04996-SP 2 Door, Front Top M/01294-XXSP 3 4 Door, Front Bottom w/slots 1,2 (shown) Door, Front Bottom w/ext. Fresh Air Hood (not shown) Fresh Air Hood - Interior 1,3 (shown) Fresh Air Hood & Damper- Exterior (not shown) M/06745-XXSP M/01295-XXSP 06801-XXSP 02109-XXSP 5 Guard, Condenser Coil P/81397 6 Door, Disconnect Access M/01368-XXSP 7 8 Panel, Left Side - ComPac I Panel, Left Side - ComPac II Panel, Right Side - ComPac I Panel, Right Side - ComPac II M/01558-XXSP M/01293-XXSP M/01557-XXSP M/01292-XXSP 9 Panel, Top M/01291-XXSP 10 Door, Heater Access M/01324-XXSP 11 Base Pan M/01680-XXSP 12 Screen, Side P/81396 XX is for color. BG=Beige, GY=Gray, WH=White, BR=Brown, AF=Aluminum, SS=Stainless steel 1 For models with the N ventilation option 2 For models with the Y, Z, C and B ventilation option. These units do not require an internal fresh air hood. 3 Models with the Y, Z, C and B ventilation option do not require an internal fresh air hood. 1 COMPAC PARTS LIST, 09/09

ECONOMIZER ASSEMBLY (COMPAC II A/C ONLY) 1 Economizer Assembly* S/03492 2 Motor, Economizer Damper 40101 *Cannot be field installed. 2 COMPAC PARTS LIST, 09/09

ELECTRICAL CONTROL BOX 1 Compressor Capacitor 208/230 V. 1Ø for Copeland Scroll Compressors Compressor Capacitor 208/230 V. 1Ø for Sanyo Scroll Compressors 50322 50294 50315 (2) n/a n/a 50327 2 Indoor Blower Motor Capacitor (IBMC) 50360 3 Compressor Contactor for All 1Ø Units 50020 50020 50030 Compressor Contactor for All 3Ø Units 50040 4 Outdoor Fan Motor Capacitor - Standard 50240 Outdoor Fan Motor Capacitor - Extreme Duty 50360 5 Fan Cycle Control Relay (FCCR) P/50182 6 Mixed Air Relay* (MAR) 50164 7 Heat Contactor See Electric Heater, Contactor, and Thermal Limit Chart** 8 Air Conditioner Circuit Board 70281 9 H205 Enthalpy Controller* 70230 10 24 Volt Transformer (XFMR) 50141 11 Low Voltage Terminal Board 80786 Disconnect 240 V. 1Ø & 220 V. 1Ø 70178 12 Disconnect 240 V. 3Ø & 220 V. 3Ø 70183 Disconnect 460 V. 3Ø (Cutler Hammer) 70299 Disconnect 460 V. 3Ø (Merlin Gerin P/n NENL34040) 70435 *ComPac II air conditioners with factory installed economizer only. **Electric Heater, Contactor & Thermal Limit Chart located on following page. 3 COMPAC PARTS LIST, 09/09

ELECTRIC HEATER, HEATER CONTACTOR & THERMAL LIMITS Heater Element Dual Limit Control Single Function Limit Switch Heater Contactor KW Volts Part QTY Part QTY Part Part 4 240 70413 1 70006 1 70005 50020 5 240 70412 1 70006 1 70005 50020 6 240 70444 3 70006 1 70005 50040 8 240 70414 2 70006 1 70005 50030 9 240 70445 3 70006 1 70005 50040 10 240 70411 2 70006 1 70005 50030 12 240 70446 3 70006 1 70005 50040 15 240 70410 3 70006 1 70005 50040 6 460 70440 3 70006 1 70005 50040 9 460 70441 3 70006 1 70005 50040 12 460 70442 3 70006 1 70005 50040 15 460 70443 3 70006 1 70005 50040 4 COMPAC PARTS LIST, 09/09

INDOOR BLOWER (BLOWER FILTER) 1 Left Hand Blower Wheel and Housing 30090 2 Right Hand Blower Wheel and Housing 30092 3 Blower Motor Bracket 80428 4 Indoor Blower Motor 40099 40099 40046 5 Drain Pan 02969SP 02930SP 02930SP 6 Bolt to Secure Blower Bracket to Housing 90736 7 Grommet for Blower Bracket 80429 8 Nut for Motor Bracket Clamp 90610 9 Bolt for Motor Bracket Clamp 90550 10 Filter, 2 80162 11 Mixed Air Sensor* 70229 Blower Assembly Includes Motor, Motor Bracket, Left Hand Blower Wheel and Housing and Right Hand Blower Wheel and Housing S/03464SP S/03464SP S/03677SP *ComPac II air conditioners with factory installed economizer only. 5 COMPAC PARTS LIST, 09/09

INDOOR COIL, BLOWER & HEATER (INDOOR COIL BLOWER) 1 Coil, Indoor 60360 60340 60061 2 Distributor, Indoor N/A N/A 20033 Capillary Tube/Strainer Assembly 20318 20297 N/A Orifice (Cooling) N/A N/A 20078 (.088) 3 Heater See Heater Chart 4 Switch, Dual Function Thermal Cut-Out Switch 70006 5 Switch, Single Function Thermal Cut-Out Switch 70005 6 Panel, Back (Galvanized) M/04996-SP 7 Panel, Left - ComPac I N/01558-XXSP 8 Left Hand Blower Wheel & Housing 30090 9 Right Hand Blower Wheel & Housing 30092 10 Filter, 2 80162 11 Mixed Air Sensor* 70229 *ComPac II air conditioners with factory installed economizer only. 6 COMPAC PARTS LIST, 09/09

COMPRESSOR & OUTDOOR COIL (OUTDOOR COIL) Compressor (Copeland), 208-230v. 1ø, 60 Hz 10052 10202 10096 1 Compressor (Sanyo), 208-230v. 1ø, 60 Hz N/A N/A 10348 Compressor, 208-230v. 3ø, 60 Hz 10093 10203 10097 Compressor, 460v. 3ø, 60 Hz 10094 10204 10098 2 High Pressure Switch 70080 70080 70279 3 Low Pressure Switch 70050 4 Filter Drier 70370 70389 70389 5 Low Ambient Fan Cycle Control S/03988* 6 High Pressure Refrigerant Access Valve 20237 7 Low Pressure Refrigerant Access Valve 20237 Continues on next page 7 COMPAC PARTS LIST, 09/09

COMPRESSOR & OUTDOOR COIL (OUTDOOR COIL) Continued from previous page 8 Fan Blade 30135 9 Motor, Outdoor Fan (Standard) 40098 Motor, Outdoor Fan (Extreme Duty) 40051 10 Condenser Coil 60350 60345 60345 11 Outdoor Fan Venturi Panel (Galvanized) 01812-SP 12 Panel, Right Side - ComPac I M/01557-XXSP 13 Bolt, Outdoor Motor Bracket 90550 14 Nut, Outdoor Motor Bracket 90610 15 Bracket, Outdoor Fan Motor 80426 Transformer, 460v. to 230v. Only on 460v. Models. 50147 50147 P/50007 *The S/03988 is the field replacement of the factory installed low ambient fan cycle control, includes swivel tee. Not Shown 8 COMPAC PARTS LIST, 09/09