RACK-MOUNT Air Conditioners

Similar documents
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ USA Phone: web:

Thermal Management INDEX. Management. Thermal TM-1

GENESIS Indoor Air Conditioners

Featured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

Top-Mount Air Conditioners

SPECTRACOOL INDOOR/OUTDOOR

N Volt 1800 BTU/Hr. 527 Watt

PROAIR Harsh Environment/Wash Down Air Conditioners

CHAPTER12. Thermal Management. Featured Products in this Chapter. Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P.

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic

SPECTRACOOL Indoor & Outdoor Air Conditioners

G /6000 BTU/Hr. 1172/1758 Watt

N Volt 1800 BTU/Hr. 527 Watt

5736 N. Michigan Road Indianapolis, IN 46228

5736 N. Michigan Road Indianapolis, IN 46228

G /6000 BTU/Hr. 1172/1758 Watt

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

SPECTRACOOL Indoor & Outdoor Air Conditioners

Quality Enclosures. Service Excellence.

GENESIS AIR CONDITIONERS

KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET

T-Series Air Conditioner T20 Model

T-Series Air Conditioner T15 Model

Quality Products. Service Excellence.

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-Series Air Conditioner T53 Model

D E F E N D E R Datacom Cabinets

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Enclosure Cooling, Venting, Heating & Purging Solutions. Celebrating 20 Years of Excellence

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

ProAir CR29 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

ClimaGuard Outdoor Heat Exchanger All Models

FIGURE 1 Forced Convection Method. Filter & Grille Required. Ambient Air. Filter & Grille Required

ProAir CR23 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

NOREN Products. Compact Cabinet Coolers

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

ProAir CR43 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

E Z S E R I E S " W X 16" H

AIR TO AIR HEAT EXCHANGERS

SEALED ENCLOSURE COOLING

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 500 Btu MODEL # S

Indirect Gas-Fired Make-Up Air

VA G 052 S

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 1500 Btu MODEL # S

Guardian/GuardianX Series NEMA 4 or 4X Rated Air Conditioners. Air Conditioners:

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

MovinCool Classic and Classic Plus Series. The Portable Spot Cooling Solution

VERTICAL FAN COIL UNITS

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

Thermal Management and Signaling Technology

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 400 Btu MODEL # S AAC-140B-4XT-EP AAC-140B-4XT-HC-EP

M52 3-Phase INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

Power to be dissipated (Watts) x 3.17 Maximum Allowable Internal Temperature ( F) - Maximum Ambient Temperature ( F)

VENTLESS DOOR-TYPE DISHWASHER

Quality Enclosures. Service Excellence.

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

Packaged Terminal Air Conditioner (PTAC)

AirV Standard-Profile RV Air Conditioning

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option

Enclosure Cooling Solutions

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13" x 9" baking dish.

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

VariCool VAV Engineering Guide

Advance Release September 2009

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13" x 9" baking dish.

RED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

AM SELECT DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES VOLTAGE. Item # Quantity C.S.I. Section AM15

5) Do not start or stop the unit by inserting or pulling out the power plug.

Packaged Terminal Air Conditioner (PTAC)

SpaceWise Rack Our SpaceWise Rack creates more room so you can cook multiple dishes at once.

KNHX32 SERIES NEMA 4/4X AIR-TO-AIR HEAT EXCHANGERS

PROAIR Air Conditioner

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option

Wall-Mount Cabinets. Pretreated steel coated with light-gray, low-gloss, lightly textured RAL 7035 polyester powder

Wall-Mount Cabinets PROTEK Single-Door and Double-Hinged Cabinets

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

SpaceWise Rack Our SpaceWise Rack creates more room so you can cook multiple dishes at once.

Self-Contained & Split System Reverse Cycle Air Conditioners Models

Preparation Table Raised Condiment Rail models 8000N

Self-Contained & Split System Reverse Cycle Air Conditioners Models

Over-the-Range Microwave professional series

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner ADVANTAGE RP55 SERIES

Packaged Terminal Air Conditioner (PTAC)

Packaged Terminal Air Conditioner (PTAC)

Transcription:

RACK-MOUNT Air Conditioners 2000-10000 BTU/HR. 586-2930 WATTS RCR11 LB16 LB14 FEATURES RCR11 is part of the ProAir Series which combines state-of-the-art design with pleasing aesthetics. This rack mount model is an excellent, high-efficiency model with a patented airflow system that allows it to be mounted anywhere within the enclosure. RCR11 stock models have thermostat control and EMI/RFI noise suppressor. Rack mount models are ideal when it is important to keep an application self-contained within the enclosure. Unique condensate management system evaporates moisture from enclosure to ambient air eliminating drain tubes, buckets and wet floors. High CFM blowers are used for maximum airflow throughout enclosure. 100% functionally tested. Mounting gaskets, drawings and instruction manual furnished. All units use a CFC-free or environmentally safe refrigerant that is universally accepted. Some LB16 Series and LB14 Series models available with UL listing at additional cost. (UL File SA6453) Please contact the factory. NEMA 12 per UL 50 Type 12 approval on all models. OPTIONS (SEE PGS. 80-81) RCR11 LB14 LB16 Thermostat Package Thermostat/Malfunction Package Special Voltage Package Corrosive Environment Package Stainless Steel Package Heater Package N/A McLEAN MIDWEST CLOSED-LOOP COOLING Within the air conditioner, the recirculated clean enclosure air is kept separate from the ambient airflow system. This protects the electronic controls and prevents shutdowns caused by heat, humidity, dust and other contaminants.

WATER-COOLED Air Conditioners 4000-12000 BTU/HR. 1172-3516 WATTS 47WC 33WC LB11WC FEATURES Water-Cooled air conditioners are for especially hostile, dirty environments or where temperatures exceed 125 F/52 C. Varied sizes, capacities and mounting options provide a wide range of choice. 33WC and 47WC Series are side-mount models, and the LB11WC is a rack mount unit. 33WC will mount to 12" deep enclosure. Operate quietly, consume low power, no condenser blower or filter to clean, and have an extra-long operating life. Add no heat to surroundings and require no fresh air ducting. Water regulating valve and water interruption shut-down switch is standard. 100% functionally tested. Mounting gaskets, drawings and instruction manual furnished. All units use a CFC-free or environmentally safe refrigerant that is universally accepted. NEMA 12 per UL 50 Type 12 approval on all models. OTHER UNITS TO CONSIDER 33 Water-Cooled: Genesis 33NSM, pg. 32 47 Water-Cooled: 47N Series, pg. 32 OPTIONS (SEE PGS. 80-81) 33WC 47WC LB11WC Thermostat Package Thermostat/Malfunction Package Condensate Evaporator Package N/A Special Voltage Package Corrosive Environment Package* Stainless Steel Package* Heater Package * Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufactured specifically for demanding applications.

33WC Series 4000 BTU/Hr. (1172 Watts) H x W x D: 34.13" (867) x 12.38" (314) x 8.75" (222) Full BTU/Hr @ Max F/ C Max Water Shipping Load 125 F Enclosure Water Usage Weight Model Voltage Hz Amps Phase Air Temp Temp (GPM)* Lbs/Kgs 33-0416-GW0XX 115 50/60 6.0/5.8 1 3800/4000 90/32 0.5 86/39 33-0426-GW0XX 230 50/60 3.3/3.2 1 3800/4000 90/32 0.5 86/39 *Rated at 90 F inlet water and full air conditioning load. Actual usage will vary. 47WC Series 8000-12000 BTU/Hr. (2344-3516 Watts) H x W x D: 47.25" (1200) x 19" (483) x 10" (254) Full BTU/Hr @ Max F/ C Max Water Shipping Load 125 F Enclosure Water Usage Weight Model Voltage Hz Amps Phase Air Temp Temp (GPM)* Lbs/Kgs 47-0815-W0XX 115 50/60 10.0 1 6600/8000 90/32 2.0 160/73 47-0816-W0XX 115 60 10.0 1 8000 90/32 2.0 155/70 47-0825-W0XX 230 50 5.5 1 8000 90/32 2.0 155/70 47-0826-W0XX 230 60 5.0 1 8000 90/32 2.0 155/70 47-1215-W0XX 115 50/60 14.0 1 10000/12000 90/32 2.0 160/73 47-1216-W0XX 115 60 14.0 1 12000 90/32 2.0 155/70 47-1225-W0XX 230 50 7.0 1 12000 90/32 2.0 155/70 47-1226-W0XX 230 60 7.0 1 12000 90/32 2.0 155/70 *Rated at 90 F inlet water and full air conditioning load. Actual usage will vary. Most models available with Hz selector switch, if desired. Contact factory. The 50/60 Hz units, because of the addition of an autotransformer, cost more that straight 60 Hz models. Units wired for 50 Hz operation when shipped. A single internal wiring change is required for 60 Hz operation. LB11WC Series 4000 BTU/Hr. (1172 Watts) H x W x D: 10.47" (266) x 19" (483) x 19.63" (499) Full BTU/Hr @ Max F/ C Max Water Shipping Load 125 F Enclosure Water Usage Weight Model Voltage Hz Amps Phase Air Temp Temp (GPM)* Lbs/Kgs LB11-0416-GW0XX 115 50/60 9.0 1 3300/4000 90/38 1.0 105/48 LB11-0426-GW0XX 230 50/60 4.5 1 3300/4000 90/38 1.0 100/45 *Rated at 90 F inlet water and full air conditioning load. Actual usage will vary. Clean air flow McLEAN MIDWEST CLOSED-LOOP COOLING Within the air conditioner, the recirculated clean enclosure air is kept separate from the ambient airflow system. This protects the electronic controls and prevents shutdowns caused by heat, humidity, dust and other contaminants. AIR CONDITIONERS 33WC, 47WC, LB11WC WATER-COOLED

1. Cord is routed through the 2" x 11.13" return air opening (top). SIDE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing air-out and air-in openings are required in the enclosure wall. 33WC SERIES 2. Dash lines represent air conditioner. 3. Bottom opening will accommodate air conditioner or heat exchanger. 4. Cut-out dimensions 1. This cord hole may be deleted if the service cord is routed through the 3" x 16.75" return air opening. SIDE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing air-out and air-in openings are required in the enclosure wall. 47WC SERIES 2. Dash lines represent air conditioner. 3. This cut-out accommodates units to 12000 BTU/Hr. 4. Cut-out dimensions LB11WC SERIES 1. Dash lines represent 2. Entire weight of air conditioner is not intended to be supported by the mounting flanges. Slide rails should be installed. 3. Cut-out dimensions RACK MOUNT TO ENCLOSURE Unit may be rack mounted near the bottom of the enclosure as shown, or use cut-out drawing for NEMA type 12 enclosures.

1. Gasket kit for mounting to enclosure 2. Service cord terminated with appropriate plug cap. 3. Condensate drain hose 1. Gasket kit for mounting to enclosure 2. Service cord terminated with appropriate plug cap. 3. Condensate drain hose 4. This 37.06" x 16.75" area is recessed 1.44" from rear surface (referred to as the plenum ). 5. Cool air outlet dimensions for 8000-12000 BTU/Hr units. AIR CONDITIONERS 33WC, 47WC, LB11WC 1. Gasket kit for mounting to enclosure 2. Service cord terminated with appropriate plug cap. 3. Condensate drain hose WATER-COOLED

COMPACT TO FULL-SIZE Air Conditioners 1600-8500 BTU/HR. 469-2490 WATTS TM The Ultimate Line CR43 CR23 CR29 FEATURES Stock models include thermostat control and EMI/RFI noise suppressor. UL/CUL listing is standard on CR23, CR29 and CR43 stock models. The ProAir Series combines state-of-the-art design with pleasing aesthetics. This highly efficient series offers a broad range of sizes and performance capacities. For more sophisticated requirements we offer Levels II and III Smart Control. This microprocessor-based option provides programmable temperature management, digital display of enclosure temperature, as well as remote alarm capabilities. Maintenance is made easy by front cover hinging open for quick access to all components. The Flip Filter design on the CR23 and CR29 uses only 50% of the filter surface so filter can be inverted to double operating time between cleanings/replacements. EZ Mount flanges simplify installation to a two-step, one-person job. Filterless operation possible in many applications. Unique condensate management system evaporates moisture from enclosure and eliminates drain tubes, buckets and wet floors. High performance fans and blowers are ideal for densely packed enclosures. 100% functionally tested. Mounting hardware, gaskets, drawings, mounting template and instruction manual furnished. All units use a CFC-free or environmentally safe refrigerant that is universally accepted. Most models available with UL and CUL listing. (UL File SA6453) CE available upon request. Please contact the factory. NEMA 12 per UL 50 type 12 approval on all models. OTHER UNITS TO CONSIDER CR23: CR23 Stainless Steel, pg. 36; Genesis 17, pg. 20 CR29: CR29 Stainless Steel, pg. 36; Genesis 28, pg. 24 CR43: CR43 Stainless Steel pg. 36 OPTIONS (SEE PGS. 80-81) CR23 CR29 CR43 Smart Control Package Thermostat Package Thermostat/Malfunction Package Special Voltage Package Outdoor Package* Corrosive Environment Package* Stainless Steel Package SEE PAGES 36-39 Heater Package * Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufactured specifically for demanding applications. McLEAN MIDWEST CLOSED-LOOP COOLING Within the air conditioner, the recirculated clean enclosure air is kept separate from the ambient airflow system. This protects the electronic controls and prevents shutdowns caused by heat, humidity, dust and other contaminants.

CR23 1600 BTU/Hr. (469 Watts) H x W x D: 23" (584) x 10" (254) x 8.75" (222) Max Shipping BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight Model Voltage Hz Phase 131 F/131 F* 131 F/131 F 95 F/95 F* 95 F/95 F F/ C Lbs/Kgs CR23-0216-G002 STOCK 115 50/60 1 1400/1600 4.1/4.5 1500/1700 3.8/3.6 131/55 57/26 CR23-0216-G0XX 115 50/60 1 1400/1600 4.1/4.5 1500/1700 3.8/3.6 131/55 57/26 CR23-0226-G002 STOCK 230 50/60 1 1400/1600 2.2/2.2 1500/1700 2.1/1.8 131/55 57/26 CR23-0226-G0XX 230 50/60 1 1400/1600 2.2/2.2 1500/1700 2.1/1.8 131/55 57/26 *Two cooling capacities are listed to demonstrate the consistent performance throughout the typical operating range. TM CR29 2000-4000 BTU/Hr. (586-1172 Watts) H x W x D: 29.50" (749) x 15.75" (400) x 8.63" (219) TM CR23 CR29 CR43 Max Shipping BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight Model Voltage Hz Phase 131 F/131 F* 131 F/131 F 95 F/95 F* 95 F/95 F F/ C Lbs/Kgs CR29-0216-G002 STOCK 115 50/60 1 2000/2200 7.4/7.4 1700/2000 7.0/6.0 131/55 98/44 CR29-0216-G0XX 115 50/60 1 2000/2200 7.4/7.4 1700/2000 7.0/6.0 131/55 98/44 CR29-0226-G002 STOCK 230 50/60 1 2500/2700 4.6/3.9 1900/2300 4.4/3.3 131/55 98/44 CR29-0226-G0XX 230 50/60 1 2500/2700 4.6/3.9 1900/2300 4.4/3.3 131/55 98/44 CR29-0416-G002 STOCK 115 50/60 1 3500/4000 13.5/13.5 2400/2800 10.7/9.6 131/55 118/54 CR29-0416-G0XX 115 50/60 1 3500/4000 13.5/13.5 2400/2800 10.7/9.6 131/55 118/54 CR29-0426-G002 STOCK 230 50/60 1 3500/4000 6.7/6.6 2400/2800 5.9/5.3 131/55 118/54 CR29-0426-G0XX 230 50/60 1 3500/4000 6.7/6.6 2400/2800 5.9/5.3 131/55 118/54 *Because air conditioners provide less cooling at lower operating temperatures, two cooling capacity ratings are listed for each ProAir air conditioner to assist you in your selection. CR43 TM 6000-8500 BTU/Hr. (1758-2490 Watts) H x W x D: 43.31" (1100) x 15.75" (400) x 10.25" (260) Max Shipping BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight Model Voltage Hz Phase 131 F/131 F* 131 F/131 F 95 F/95 F* 95 F/95 F F/ C Lbs/Kgs CR43-0616-002 STOCK 115 60 1 6000 13.7 5100 11.0 131/55 133/60 CR43-0615-0XX 115 50/60 1 5800/6000 14.6/13.7 4800/5100 12.5/11.0 131/55 131/59 CR43-0616-0XX 115 60 1 6000 13.7 5100 11.0 131/55 131/59 CR43-0625-0XX 230 50 1 6000 6.8 5100 5.3 131/55 131/59 CR43-0626-002 STOCK 230 60 1 6000 6.9 5100 5.5 131/55 131/59 CR43-0626-0XX 230 60 1 6000 6.9 5100 5.5 131/55 131/59 CR43-0816-002 STOCK 115 60 1 8500 16.0 7500 12.9 131/55 140/64 CR43-0815-0XX 115 50/60 1 7500/8500 15.0/16.0 6700/7500 13.5/12.9 131/55 138/63 CR43-0816-0XX 115 60 1 8500 16.0 7500 12.9 131/55 138/63 CR43-0825-0XX 230 50 1 7500 8.0 7000 6.1 131/55 138/63 CR43-0826-002 STOCK 230 60 1 8500 8.2 7500 6.3 131/55 138/63 CR43-0826-0XX 230 60 1 8500 8.2 7500 6.3 131/55 138/63 *Because air conditioners provide less cooling at lower operating temperatures, two cooling capacity ratings are listed for each ProAir air conditioner to assist you in your selection. AIR CONDITIONERS CR23, CR29, CR43 TM

1. Dash lines represent SIDE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing air-out and air-in openings are required in the enclosure wall. CR23 2. Cut-out dimensions 3. Full-size mounting template provided. CR43 CR29 TM TM TM 1. Dash lines represent 2. Cut-out dimensions 3. Full-size mounting template provided. 1. Dash lines represent 2. Cut-out dimensions 3. Full-size mounting template provided. SIDE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing air-out and air-in openings are required in the enclosure wall. SIDE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing air-out and air-in openings are required in the enclosure wall.

1. Gasket kit for mounting to enclosure 2. Service cord terminated with appropriate plug cap. 1. Gasket kit for mounting to enclosure 2. Service cord terminated with appropriate plug cap. AIR CONDITIONERS CR23, CR29, CR43 1. Gasket kit for mounting to enclosure TM 2. Service cord terminated with appropriate plug cap.

OUTDOOR/CORROSIVE/STAINLESS STEEL 1600-8500 BTU/HR. 469-2490 WATTS The Ultimate Protection TM CR29 CR43 CR23 FEATURES Constructed of high-grade 16-gauge type 304 stainless steel for increased protection in corrosive and outdoor applications. The Corrosive Environment and Outdoor Option Packages can be ordered separately or together to provide optimum defense against especially harsh conditions. The Corrosive Environment Package protects components exposed to the corrosive environment on the ambient side of the The Outdoor Package includes low temperature controls for operating down to -40 F. The ProAir Series combines state-of-the-art design with pleasing aesthetics. This highly efficient series offers a broad range of sizes and performance capacities. For more sophisticated requirements we offer Levels II and III Smart Control. This microprocessor-based option provides programmable temperature management, digital display of enclosure temperature, as well as remote alarm capabilities. Maintenance is made easy by front cover hinging open for quick access to all components. The Flip Filter design on the CR23 and CR29 uses only 50% of the filter surface so filter can be inverted to double operating time between cleanings/replacements. EZ Mount flanges simplify installation to a two-step, one-person job. Filterless operation possible in many applications. Unique condensate management system evaporates moisture from enclosure and eliminates drain tubes, buckets and wet floors. High performance fans and blowers are ideal for densely packed enclosures. 100% functionally tested. Mounting hardware, gaskets, drawings, mounting template and instruction manual furnished. All units use a CFC-free or environmentally safe refrigerant that is universally accepted. Most models available with UL and CUL listing. CE available upon request. Please contact the factory. (UL File SA6453) NEMA 12 per UL 50 Type 12 approval on all models. NEMA 4X per UL 50 Type 4X optional. OTHER UNITS TO CONSIDER CR23 Stainless Steel: CR23, pg. 16; Genesis 17, pg. 20 CR29 Stainless Steel: CR29, pg. 16; Genesis 28, pg. 24 CR43 Stainless Steel: CR43, pg. 16 OPTIONS (SEE PGS. 80-81) CR23 CR29 CR43 Smart Control Package Thermostat Package Thermostat/Malfunction Package Special Voltage Package Outdoor Package* Corrosive Environment Package* Heater Package NEMA 4X Package (see note on pg. 37) * Must be ordered separately to achieve desired protection.

TM TM TM Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Stainless Steel CR23 1600 BTU/Hr. (469 Watts) H x W x D: 23" (584) x 10" (254) x 8.75" (222) Max Shipping BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight Model Voltage Hz Phase 131 F/131 F* 131 F/131 F 95 F/95 F* 95 F/95 F F/ C Lbs/Kgs CR23-0216-G0ST 115 50/60 1 1400/1600 4.1/4.5 1500/1700 3.8/3.6 131/55 57/26 CR23-0226-G0ST 230 50/60 1 1400/1600 2.2/2.2 1500/1700 2.1/1.8 131/55 57/26-0ST will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers. * Two cooling capacities are listed to demonstrate the consistent performance throughout the typical operating range. TM TM Stainless Steel CR29 2000-4000 BTU/Hr. (586-1172 Watts) H x W x D: 29.50" (749) x 15.75" (400) x 8.63" (219) Max Shipping BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight Model Voltage Hz Phase 131 F/131 F* 131 F/131 F 95 F/95 F* 95 F/95 F F/ C Lbs/Kgs CR23 CR29 CR43 CR29-0216-G0ST 115 50/60 1 2000/2200 7.4/7.4 1700/2000 7.0/6.0 131/55 98/44 CR29-0226-G0ST 230 50/60 1 2500/2700 4.6/3.9 1900/2300 4.4/3.3 131/55 98/44 CR29-0416-G0ST 115 50/60 1 3500/4000 13.5/13.5 2400/2800 10.7/9.6 131/55 118/54 CR29-0426-G0ST 230 50/60 1 3500/4000 6.7/6.6 2400/2800 5.9/5.3 131/55 118/54-0ST will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers. *Because air conditioners provide less cooling at lower operating temperatures, two cooling capacity ratings are listed for each ProAir air conditioner to assist you in your selection. Stainless Steel CR43 6000-8500 BTU/Hr. (1758-2490 Watts) H x W x D: 43.31" (1100) x 15.75" (400) x 10.25" (260) Max Shipping BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight Model Voltage Hz Phase 131 F/131 F* 131 F/131 F 95 F/95 F* 95 F/95 F F/ C Lbs/Kgs CR43-0615-0ST 115 50/60 1 5800/6000 14.6/13.7 4800/5100 12.5/11.0 131/55 131/59 CR43-0616-0ST 115 60 1 6000 13.7 5100 11.0 131/55 131/59 CR43-0625-0ST 230 50 1 6000 6.8 5100 5.3 131/55 131/59 CR43-0626-0ST 230 60 1 6000 6.9 5100 5.5 131/55 131/59 CR43-0815-0ST 115 50/60 1 7500/8500 15.0/16.0 6700/7500 13.5/12.9 131/55 138/63 CR43-0816-0ST 115 60 1 8500 16.0 7500 12.9 131/55 138/63 CR43-0825-0ST 230 50 1 7500 8.0 7000 6.1 131/55 138/63 CR43-0826-0ST 230 60 1 8500 8.2 7500 6.3 131/55 138/63-0ST will be replaced with a two-digit number designating all desired options. Consult the factory for specific model numbers. *Because air conditioners provide less cooling at lower operating temperatures, two cooling capacity ratings are listed for each ProAir air conditioner to assist you in your selection. McLEAN MIDWEST CLOSED-LOOP COOLING Within the air conditioner, the recirculated clean enclosure air is kept separate from the ambient airflow system. This protects the electronic controls and prevents shutdowns caused by heat, humidity, dust and other contaminants. TM NEMA 4X The protective shields illustrated here are required to achieve NEMA 4X. Shield protrudes approximately 2" from the Contact factory for details. OUTDOOR/CORROSIVE/STAINLESS STEEL CR23, CR29, CR43

Stainless Steel CR23 1. Dash lines represent 2. Cut-out dimensions 3. Full-size mounting template provided. SIDE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing air-out and air-in openings are required in the enclosure wall. Stainless Steel CR29 1. Dash lines represent 2. Cut-out dimensions 3. Full-size mounting template provided. SIDE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing air-out and air-in openings are required in the enclosure wall. Stainless Steel CR43 TM TM 1. Dash lines represent 2. Cut-out dimensions 3. Full-size mounting template provided. SIDE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing air-out and air-in openings are required in the enclosure wall. TM

1. Gasket kit for mounting to enclosure 2. Service cord terminated with appropriate plug cap. 4. Dashed lines indicate optional shroud used, along with other special construction features, for NEMA 4X. Please contact factory for details. 1. Gasket kit for mounting to enclosure 2. Service cord terminated with appropriate plug cap. 4. Dashed lines indicate optional shroud used, along with other special construction features, for NEMA 4X. Please contact factory for details. 1. Gasket kit for mounting to enclosure 2. Service cord terminated with appropriate plug cap. 4. Dashed lines indicate optional shroud used, along with other special construction features, for NEMA 4X. Please contact factory for details. OUTDOOR/CORROSIVE/STAINLESS STEEL CR23, CR29, CR43

NARROW Air Conditioners 4000-10000 BTU/HR. 1172-2930 WATTS 47N 36N 33NSM FEATURES Stock models are equipped with a thermostat control that offers convenient digital display of enclosure temperature and high temperature alarm (125ºF/52ºC). Flashing display indicates alarm condition. EMI/RFI noise suppressor and UL/CUL and CE listing are standard on stock models. New Genesis 33NSM and 36N models offer: improved aesthetics with no changes to the major internal components so airflow and performance are the same as the corresponding Slimboy models; unique condensate management system evaporates moisture from enclosure and eliminates drain tubes, buckets and wet floors in typical applications; and EZ Mount flanges simplify installation to a two-step, one-person job. Genesis units are directly interchangeable with the comparable Slimboy Series, however, the Genesis 33NSM does not come equipped with a backplane like the old Slimboy model. Narrow models offer a broad capacity range with the advantage of mounting on narrow enclosures. The 33NSM Series is only 12" wide, and the 36N and 47N Series are only 15" wide. High performance, industrial-grade ball bearing fans in the 33NSM, and high performance blowers in the 36N and 47N, provide maximum heat transfer in densely packed enclosures. Most components accessible by removing air filter. 100% functionally tested. Mounting gaskets, drawings and instruction manual furnished. All units use a CFC-free or environmentally safe refrigerant that is universally accepted. UL/CUL listing and CE standard on all Genesis 33NSM and 36N models. (UL File SA6453) Please contact the factory. NEMA 12 per UL 50 type 12 approval on all models. OTHER UNITS TO CONSIDER Genesis 33NSM: 33 Water-Cooled, pg. 40 47N Series: 47 Water-Cooled, pg. 40 OPTIONS (SEE PGS. 80-81) 33NSM 36N 47N Thermostat Package Thermostat/Malfunction Package Condensate Evaporator Package ** ** Special Voltage Package Outdoor Package* Corrosive Environment Package* Stainless Steel Package* Heater Package * Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufactured specifically for demanding applications. ** A condensate management system is standard. See features.

GENESIS 33NSM Series 4000 BTU/Hr. (1172 Watts) H x W x D: 34.37" (873) x 12" (305) x 9.88" (251) Full BTU/Hr @ Max Shipping Load Max Amb Amb Temp Weight Model Voltage Hz Amps Phase Temp F/ C Lbs/Kgs M33-0416-G010 STOCK 115 50/60 13.0/13.2 1 3700/4000 125/52 105/48 M33-0416-G0XX 115 50/60 13.0/13.2 1 3700/4000 125/52 105/48 M33-0426-G009 STOCK 230 50/60 7.2/7.3 1 3700/4000 125/52 105/48 M33-0426-G0XX 230 50/60 7.2/7.3 1 3700/4000 125/52 105/48 An M in the model number identifies the new Genesis Series of air conditioners. GENESIS 36N Series 6000 BTU/Hr. (1758 Watts) H x W x D: 38.72" (984) x 15" (381) x 11.33" (288) Full BTU/Hr @ Max Shipping Load Max Amb Amb Temp Weight Model Voltage Hz Amps Phase Temp F/ C Lbs/Kgs 33NSM 36N M36-0616-307 STOCK 115 50/60 14.0/14.0 1 5000/6000 125/52 120/54 M36-0616-3XX 115 50/60 14.0/14.0 1 5000/6000 125/52 120/54 M36-0626-306 STOCK 230 50/60 7.0/7.0 1 5000/6000 125/52 120/54 M36-0626-3XX 230 50/60 7.0/7.0 1 5000/6000 125/52 120/54 An M in the model number identifies the new Genesis Series of air conditioners. 47N Series 8000-10000 BTU/Hr. (2344-2930 Watts) H x W x D: 49.13" (1248) x 15" (381) x 10.50" (267) Full BTU/Hr @ Max Shipping Load Max Amb Amb Temp Weight Model Voltage Hz Amps Phase Temp F/ C Lbs/Kgs 47-0815-3XX 115 50/60 18.0 1 6700/8000 125/52 150/68 47-0816-3XX 115 60 18.0 1 8000 125/52 150/68 47-0825-3XX 230 50 9.0 1 8000 125/52 150/68 47-0826-3XX 230 60 9.0 1 8000 125/52 150/68 47-1015-3XX 115 50/60 18.0 1 8300/10000 125/52 155/70 47-1016-3XX 115 60 18.0 1 10000 125/52 155/70 47-1025-3XX 230 50 10.0 1 10000 125/52 155/70 47-1026-3XX 230 60 9.0 1 10000 125/52 155/70 Most models available with Hz selector switch, if desired. Contact factory. The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. A single internal wiring change is required for 60 Hz operation. AIR CONDITIONERS 33NSM, 36N, 47N 47N McLEAN MIDWEST CLOSED-LOOP COOLING Within the air conditioner, the recirculated clean enclosure air is kept separate from the ambient airflow system. This protects the electronic controls and prevents shutdowns caused by heat, humidity, dust and other contaminants. NARROW

GENESIS 33NSM Series 1. Cord is routed through the 2" x 11.12" return air opening (top). 2. Dash lines represent 3. Cut-out dimensions 4. Bottom opening will accommodate air conditioner or heat exchanger. 5. Full-size mounting template provided. SIDE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing air-out and air-in openings are required in the enclosure wall. GENESIS 36N Series 1. Service cord is routed through the 3" x 14" return air opening. 2. Dash lines represent 3. Cut-out dimensions 4. Full-size mounting template provided. SIDE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing air-out and air-in openings are required in the enclosure wall. 1. Dash lines represent 2. Cut-out dimensions SIDE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing air-out and air-in openings are required in the enclosure wall. 47N Series

1. Gasket kit for mounting to enclosure 2. Service cord. 3. This 25.58" x 11" area is recessed 1.12" from rear surface (referred to as the plenum ). 5. Condenser air discharge out front is optional. 1. Gasket kit for mounting to enclosure 2. Service cord. 3. This 14" x 29.13" area is recessed 1.44" from rear surface (referred to as the plenum ). 4. Condenser air discharge out front is optional. 1. Gasket kit for mounting to enclosure 2. Service cord terminated with appropriate plug cap. 3. This 36.13" x 14" area is recessed 1.63" from rear surface (referred to as the plenum ). AIR CONDITIONERS 33NSM, 36N, 47N NARROW

MID-SIZE Air Conditioners 2000-6000 BTU/HR. 586-1758 WATTS 28 36 FEATURES Genesis 28 stock models are equipped with a thermostat control that offers convenient digital display of enclosure temperature and high temperature alarm (125ºF/52ºC). Flashing display indicates alarm condition. 36 Series stock models have an electro-mechanical thermostat. Genesis 28 stock models are UL/CUL and CE standard. Both Series include EMI/RFI noise suppressor on stock models. New Genesis 28 models offer: improved aesthetics with no changes to the major internal components so airflow and performance are the same as the corresponding Slimboy models; unique condensate management system evaporates moisture from enclosure and eliminates drain tubes, buckets and wet floors in typical applications; and EZ Mount flanges simplify installation to a twostep, one-person job. Genesis units are directly interchangeable with the comparable Slimboy Series. A field retrofit plate is needed only when mounting the Genesis 28 to an old Slimboy model cutout. Plate is free upon request. For Slimboy 28 models with side mounting rails, field retrofit plate part number is 28-plate. For other mounting configurations, contact the factory. The Mid-Size models offer universal sizes and a broad performance range making them some of the most popular in the industry. High CFM ball-bearing centrifugal blowers are ideal for densely packaged enclosures. Most components accessible by removing air filter. 100% functionally tested. Mounting gaskets, drawings and instruction manual furnished. All units use a CFC-free or environmentally safe refrigerant that is universally accepted. UL/CUL listing and CE standard on all Genesis 28 models. Certain 36 models available with UL listing. (UL File SA6453). Please contact the factory. NEMA 12 per UL 50 type 12 approval on all models. OTHER UNITS TO CONSIDER Genesis 28: CR29, pg. 16; CR29 Stainless Steel, pg. 36 36 Series: Genesis 36N, pg. 32 OPTIONS (SEE PGS. 80-81) 28 36 Thermostat Package Thermostat/Malfunction Package Condensate Evaporator Package ** Special Voltage Package Outdoor Package* Heater Package Corrosive Environment Package* Stainless Steel Package* * Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufactured specifically for demanding applications. ** A condensate management system is standard. See features.

GENESIS 28 Series 2000-6000 BTU/Hr. (586-1758 Watts) H x W x D: 28.50" (724) x 17" (432) x 11.33" (288) Full BTU/Hr @ Max Shipping Load Max Amb Amb Temp Weight Model Voltage Hz Amps Phase Temp F/ C Lbs/Kgs M28-0216-G013 STOCK 115 50/60 9.8/9.0 1 2200/2200 125/52 98/45 M28-0216-G0XX 115 50/60 9.8/9.0 1 2200/2200 125/52 98/45 M28-0226-G004 STOCK 230 50/60 5.0/4.5 1 2200/2200 125/52 98/45 M28-0226-G0XX 230 50/60 5.0/4.5 1 2200/2200 125/52 98/45 M28-0416-G007 STOCK 115 50/60 14.6/14.0 1 3800/4000 125/52 116/53 M28-0416-G0XX 115 50/60 14.6/14.0 1 3800/4000 125/52 116/53 M28-0426-G032 STOCK 230 50/60 7.4/6.9 1 3800/4000 125/52 116/53 M28-0426-G0XX 230 50/60 7.4/6.9 1 3800/4000 125/52 116/53 M28-0616-0XX 115 50/60 15.0/15.0 1 5400/6000 125/52 120/55 M28-0626-0XX 230 50/60 7.3/7.3 1 5400/6000 125/52 120/55 An M in the model number identifies the new Genesis Series of air conditioners. 36 Series 6000 BTU/Hr. (1758 Watts) H x W x D: 36.69" (932) x 19" (483) x 10.88" (276) Full BTU/Hr @ Max Shipping Load Max Amb Amb Temp Weight Model Voltage Hz Amps Phase Temp F/ C Lbs/Kgs 36-0616-136 STOCK 115 60 14.0 1 6000 125/52 129/59 36-0615-1XX 115 50/60 14.0 1 5000/6000 125/52 131/59 36-0616-1XX 115 60 14.0 1 6000 125/52 126/57 36-0625-1XX 230 50 7.0 1 6000 125/52 126/57 36-0626-113 STOCK 230 60 7.0 1 6000 125/52 126/57 36-0626-1XX 230 60 7.0 1 6000 125/52 126/57 Most models available with Hz selector switch, if desired. Contact factory. The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. A single internal wiring change is required for 60 Hz operation. McLEAN MIDWEST CLOSED-LOOP COOLING Within the air conditioner, the recirculated clean enclosure air is kept separate from the ambient airflow system. This protects the electronic controls and prevents shutdowns caused by heat, humidity, dust and other contaminants. AIR CONDITIONERS 28, 36 Ambient air flow Clean air flow 28 36 MID-SIZE

GENESIS 28 Series 1. Dash lines represent SIDE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing air-out and air-in openings are required in the enclosure wall. 2. Cut-out dimensions 3. This hole may be deleted if the service cord is routed through the 3" x 13.50" return air opening. 4. Full-size mounting template provided. 1. Gasket kit for mounting to enclosure 2. Service cord. 4. This 20.50" x 15.50" area is recessed 1.00" from rear surface (referred to as the plenum ). 5. Condenser air discharge out front is optional.

36 Series 1. This cord hole may be deleted if the service cord is routed through the 3" x 16.75" return air opening. SIDE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing airout and air-in openings are required in the enclosure wall. 2. Dash lines represent 3. Cut-out dimensions 1. Gasket kit for mounting to enclosure 2. Service cord terminated with appropriate plug cap. 3. This 30.06" x 16.75" area is recessed.94" from rear surface (referred to as the plenum ). MID-SIZE AIR CONDITIONERS 28, 36

FULL-SIZE Air Conditioners 6000-20000 BTU/HR. 1758-5860 WATTS 52 52HC FEATURES Stock models are equipped with a thermostat control that offers convenient digital display of enclosure temperature and high temperature alarm (125ºF/52ºC). Flashing display indicates alarm condition. EMI/RFI noise suppressor and UL/CUL and CE are standard on stock models of 6,000 and 8,000 BTU/Hr. models. On 10,000 and 12,000 BTU/Hr. models of the Genesis 52 Series, the 115 volt stock model is UR/CUR recognized. New Genesis 52 models offer: improved aesthetics with no changes to the major internal components so airflow and performance are the same as the corresponding Slimboy models; unique condensate management system evaporates moisture from enclosure and eliminates drain tubes, buckets and wet floors in typical applications; and EZ Mount flanges simplify installation to a twostep, one-person job. Genesis units are directly interchangeable with the comparable Slimboy Series. A field retrofit plate is needed only when mounting the Genesis 52 to an old Slimboy model cutout. Plate is free upon request. For Slimboy 52 models with side mounting rails, field retrofit plate part number is 52-plate. For other mounting configurations, contact the factory. Full-Size models offer the highest cooling capacities in McLean's extensive air conditioner range. McLean s highest performance CFM ball-bearing centrifugal blowers are ideal for densely packed enclosures. Most components accessible by removing air filter. 100% functionally tested. Mounting gaskets, drawings and instruction manual furnished. All units use a CFC-free or environmentally safe refrigerant that is universally accepted. UL/CUL listing and CE standard on most Genesis 52 models, except the 115 volt, Genesis 52 series in the 10,000 and 12,000 BTU/Hr. which are UR/CUR recognized. Certain 52HC models available with UL listing. (UL File SA6453) Please contact the factory. NEMA 12 per UL 50 type 12 approval on all models. OPTIONS (SEE PGS. 80-81) 52 52HC Thermostat Package Thermostat/Malfunction Package Condensate Evaporator Package ** Special Voltage Package Outdoor Package* Corrosive Environment Package* Stainless Steel Package* Heater Package * Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufactured specifically for demanding applications. ** A condensate management system is standard. See features.

GENESIS 52 Series 6000-12000 BTU/Hr. (1758-3516 Watts) H x W x D: 52.63" (1337) x 17.13" (435) x 11.33" (288) Full BTU/Hr @ Max Shipping Load Max Amb Amb Temp Weight Model Voltage Hz Amps Phase Temp F/ C Lbs/Kgs M52-0616-0XX 115 50/60 13.0/13.0 1 5000/6000 125/52 155/70 M52-0626-0XX 230 50/60 6.5/6.5 1 5000/6000 125/52 155/70 M52-0816-032 STOCK 115 50/60 14.5/14.5 1 6700/8000 125/52 160/73 M52-0816-0XX 115 50/60 14.5/14.5 1 6700/8000 125/52 160/73 M52-0826-015 STOCK 230 50/60 8.0/8.0 1 6700/8000 125/52 160/73 M52-0826-0XX 230 50/60 8.0/8.0 1 6700/8000 125/52 160/73 M52-1016-038 STOCK 110/115 50/60 18.9/19.5 1 8300/10000 125/52 165/75 M52-1016-0XX 110/115 50/60 18.9/19.5 1 8300/10000 125/52 165/75 M52-1026-021 STOCK 220/230 50/60 9.5/9.8 1 8300/10000 125/52 165/75 M52-1026-0XX 220/230 50/60 9.5/9.8 1 8300/10000 125/52 165/75 M52-1216-017 STOCK 110/115 50/60 24.0/23.0 1 10000/12000* 125/52 175/79 M52-1216-0XX 110/115 50/60 24.0/23.0 1 10000/12000* 125/52 175/79 M52-1226-034 STOCK 220/230 50/60 12.0/11.6 1 10000/12000* 125/52 175/79 M52-1226-0XX 220/230 50/60 12.0/11.6 1 10000/12000* 125/52 175/79 Most models available with Hz selector, if desired. Contact factory. The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. A single internal wiring change is required for 60 Hz operation. * Based on return air temperature slightly above ambient. An M in the model number identifies the new Genesis Series of air conditioners. 52HC Series 14000-20000 BTU/Hr. (4100-5860 Watts) H x W x D: 52.50" (1333) x 23" (584) x 12.88" (327) Full BTU/Hr @ Max Shipping Load Max Amb Amb Temp Weight Model Voltage Hz Amps Phase Temp F/ C Lbs/Kgs 52-1425-0XX 230 50 14.0 1 14000 125/52 220/100 52-1426-0XX 230 60 14.0 1 14000 125/52 220/100 52-1625-0XX 230 50 16.0 1 16000 125/52 225/102 52-1626-0XX 230 60 17.0 1 16000 125/52 225/102 52-1926-0XX 230 50/60 18.8/18.8 1 17500/20000 125/52 235/107 McLEAN MIDWEST CLOSED-LOOP COOLING Within the air conditioner, the recirculated clean enclosure air is kept separate from the ambient airflow system. This protects the electronic controls and prevents shutdowns caused by heat, humidity, dust and other contaminants. Ambient air flow Clean air flow AIR CONDITIONERS 52, 52HC FULL-SIZE

GENESIS 52 Series 1. Dash lines represent SIDE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing air-out and air-in openings are required in the enclosure wall. 2. Cut-out dimensions 3. This cord hole may be deleted if the service cord is routed through the 4.50" x 15.63" return air opening (except units with electric heat). 4. Full-size mounting template provided. 1. Gasket kit for mounting to enclosure 2. Service cord. 3. This 42.06" x 15.63" area is recessed 1.44" from rear surface (referred to as the plenum ). 4. Condenser air discharge out front is optional.

52HC Series 1. Dash lines represent 2. Cut-out dimensions SIDE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing airout and air-in openings are required in the enclosure wall. Refer to mounting dimensions. 1. Gasket kit for mounting to enclosure 2. This 47" x 20.88" area is recessed 1.69" from rear surface (referred to as the plenum ). 3. Service cord terminated with appropriate plug cap. * Dimensional changes required to accommodate autotransformer on 50/60 Hz units. FULL-SIZE AIR CONDITIONERS 52, 52HC

COMPACT Air Conditioners 1000-1800 BTU/HR. 293-527 WATTS 13 17 FEATURES Stock models are equipped with a thermostat control that offers convenient digital display of enclosure temperature and high temperature alarm (125ºF/52ºC). Flashing display indicates alarm condition. EMI/RFI noise suppressor and UL/CUL and CE are standard on stock models. New Genesis models offer improved aesthetics with no changes to the major internal components so airflow and performance are the same as the corresponding Slimboy models. Genesis units are directly interchangeable with the comparable Slimboy Series. Unique condensate management system evaporates moisture from enclosure and eliminates drain tubes, buckets and wet floors in typical applications. Compact models are ideal for cooling smaller enclosures from 25 cu. ft. to 40 cu. ft. The ultra-narrow 17 Series is only 12" wide making it perfect for enclosures with narrow side walls. EZ Mount flanges simplify installation to a two-step, one-person job. High-performance, industrial-grade ball-bearing fans used to provide maximum heat transfer. Most components accessible by removing grille/filter. 100% functionally tested. Mounting hardware, gaskets, drawings, mounting template and instruction manual furnished. All units use a CFC-free or environmentally safe refrigerant that is universally accepted. UL/CUL listing and CE standard on all models. (UL File SA6453). Please contact the factory. NEMA 12 per UL 50 type 12 approval on all models. OTHER UNITS TO CONSIDER Genesis 17: CR23, pg. 16; CR23 Stainless Steel, pg. 36 OPTIONS (SEE PGS. 80-81) 13 17 Thermostat Package Thermostat/Malfunction Package Special Voltage Package Outdoor Package* Corrosive Environment Package* Stainless Steel Package* * Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufactured specifically for demanding applications.

GENESIS 13 Series 1000 BTU/Hr. (293 Watts) H x W x D: 13.25" (337) x 14.25" (362) x 7.80" (198) Full BTU/Hr @ Max Shipping Load Max Amb Amb Temp Weight Model Voltage Hz Amps Phase Temp F/ C Lbs/Kgs M13-0116-G1014 STOCK 115 50/60 4.0/4.0 1 800/1000 125/52 48/22 M13-0116-G1XXX 115 50/60 4.0/4.0 1 800/1000 125/52 48/22 M13-0126-G1008 STOCK 230 50/60 2.2/2.1 1 800/1000 125/52 48/22 M13-0126-G1XXX 230 50/60 2.2/2.1 1 800/1000 125/52 48/22 -XXX will be replaced with a three-digit number designating all desired options. Consult the factory for specific model numbers. An M in the model number identifies the new Genesis Series of air conditioners. GENESIS 17 Series 1800 BTU/Hr. (527 Watts) H x W x D: 17.65" (448) x 12" (305) x 8.68" (220) Full BTU/Hr @ Max Shipping Load Max Amb Amb Temp Weight Model Voltage Hz Amps Phase Temp F/ C Lbs/Kgs M17-0216-G009 STOCK 110/115 50/60 6.6/6.7 1 1500/1800 125/52 56/25 M17-0216-G0XX 110/115 50/60 6.6/6.7 1 1500/1800 125/52 56/25 M17-0226-G004 STOCK 220/230 50/60 4.2/3.7 1 1500/1800 125/52 56/25 M17-0226-G0XX 220/230 50/60 4.2/3.7 1 1500/1800 125/52 56/25 An "M" in the model number identifies the new Genesis Series of air conditioners. McLEAN MIDWEST CLOSED-LOOP COOLING Within the air conditioner, the recirculated clean enclosure air is kept separate from the ambient airflow system. This protects the electronic controls and prevents shutdowns caused by heat, humidity, dust and other contaminants. Ambient air flow Clean air flow AIR CONDITIONERS 13, 17 13 17 COMPACT

GENESIS 13 Series 1. Dash lines represent 2. Cut-out dimensions SIDE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing air-out and air-in openings are required in the enclosure wall. Generally, the 13 Series is most effective on enclosures up to 25 cu. ft., unless the application is only for spot cooling in a larger enclosure. 3. Full-size mounting template provided. 1. Gasket kit for mounting to enclosure 2. Service cord.

GENESIS 17 Series 1. Dash lines represent 2. Cut-out dimensions 3. Full-size mounting template provided. SIDE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing airout and air-in openings are required in the enclosure wall. Generally, the 17 Series is most effective on enclosures up to 40 cu. ft., unless the application is only for spot cooling in a larger enclosure. 1. Gasket kit for mounting to enclosure 2. Service cord. 3. Condensate from enclosure drains to bottom pan of unit where it is evaporated by condenser heat. COMPACT AIR CONDITIONERS 13, 17

TOP-MOUNT Air Conditioners 2000-9000 BTU/HR. 586-2637 WATTS HB11 HB16 HB30 FEATURES Stock HB11 models are equipped with a thermostat control that offers convenient digital display of enclosure temperature and high temperature alarm (125ºF/52ºC). Flashing display indicates alarm condition. EMI/RFI noise suppressor and UR/CUR and CE are standard on stock models. New Genesis HB11 models offer: improved aesthetics with no changes to the major internal components so airflow and performance are the same as the corresponding Slimboy model. Genesis units are directly interchangeable with the comparable Slimboy Series. HB11 and HB30 models have a unique condensate management system that evaporates moisture from enclosure and eliminates drain tubes, buckets and wet floors in typical applications. Top-Mount air conditioners are ideal for use where there is little or no clearance around the enclosure. High CFM ball-bearing centrifugal blowers are ideal for densely packaged enclosures. 100% functionally tested. Mounting gaskets, drawings and instruction manual furnished. All units use a CFC-free or environmentally safe refrigerant that is universally accepted. UL recognized, CUL recognized and CE standard on all Genesis HB11 models. Certain HB16 models available with UL listing. (UL File SA6453) Please contact the factory. NEMA 12 per UL 50 type 12 approval on all models. OPTIONS (SEE PGS. 80-81) HB11 HB16 HB30 Thermostat Package Thermostat/Malfunction Package Special Voltage Package Corrosive Environment Package* Stainless Steel Package* Heater Package * Please refer to pgs. 36-39 for our air conditioners that have been engineered and manufactured specifically for demanding applications. McLEAN MIDWEST CLOSED-LOOP COOLING Within the air conditioner, the recirculated clean enclosure air is kept separate from the ambient airflow system. This protects the electronic controls and prevents shutdowns caused by heat, humidity, dust and other contaminants.

GENESIS HB11 Series 2000-4000 BTU/Hr. (586-1172 Watts) H x W x D: 10.25" (260) x 17" (432) x 21.08" (535) Full BTU/Hr @ Max Shipping Load Max Amb Amb Temp Weight Model Voltage Hz Amps Phase Temp F/ C Lbs/Kgs MHB11-0216-G306 STOCK 115 50/60 9.7/9.0 1 2200/2200 125/52 90/41 MHB11-0216-G3XX 115 50/60 9.7/9.0 1 2200/2200 125/52 90/41 MHB11-0226-G306 STOCK 230 50/60 5.5/4.6 1 2200/2200 125/52 90/41 MHB11-0226-G3XX 230 50/60 5.5/4.6 1 2200/2200 125/52 90/41 MHB11-0416-G307 STOCK 110/115 50/60 14.7/13.6 1 3300/4000 125/52 108/49 MHB11-0416-G3XX 110/115 50/60 14.7/13.6 1 3300/4000 125/52 108/49 MHB11-0426-G306 STOCK 220/230 50/60 8.0/7.5 1 3300/4000 125/52 108/49 MHB11-0426-G3XX 220/230 50/60 8.0/7.5 1 3300/4000 125/52 108/49 An M in the model number identifies the new Genesis Series of air conditioners. HB16 Series 6000-9000 BTU/Hr. (1758-2637 Watts) H x W x D: 15.72" (399) x 19" (483) x 25.19" (640) Full BTU/Hr @ Max Shipping Load Max Amb Amb Temp Weight Model Voltage Hz Amps Phase Temp F/ C Lbs/Kgs HB16-0615-0XX 115 50/60 13.0 1 5000/6000 125/52 145/66 HB16-0616-0XX 115 60 13.0 1 6000 125/52 140/64 HB16-0625-0XX 230 50 6.5 1 6000 125/52 140/64 HB16-0626-0XX 230 60 6.5 1 6000 125/52 140/64 HB16-0825-0XX 230 50 8.0 1 8000 125/52 145/66 HB16-0915-0XX 115 50/60 17.0 1 8500/9000 125/52 150/68 HB16-0916-0XX 115 60 19.0 1 9000 125/52 145/66 HB16-0926-0XX 230 60 9.5 1 9000 125/52 145/66 Most models available with Hz selector, if desired. Contact factory. The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. A single internal wiring change is required for 60 Hz operation. HB30 Series 6000 BTU/Hr. (1758 Watts) H x W x D: 14.13" (359) x 31.38" (797) x 15" (381) Full BTU/Hr @ Max Shipping Load Max Amb Amb Temp Weight Model Voltage Hz Amps Phase Temp F/ C Lbs/Kgs AIR CONDITIONERS HB11, HB16, HB30 HB30-0615-1XX 115 50/60 14.0 1 5000/6000 125/52 136/62 HB30-0616-1XX 115 60 14.0 1 6000 125/52 131/59 HB30-0625-1XX 230 50 7.0 1 6000 125/52 131/59 HB30-0626-1XX 230 60 7.0 1 6000 125/52 131/59 Most models available with Hz selector, if desired. Contact factory. The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. A single internal wiring change is required for 60 Hz operation. TOP-MOUNT

GENESIS HB11 SERIES 1. Dash lines represent 2. Cut-out dimensions 3. Full-size mounting template provided. TOP SURFACE MOUNT TO ENCLOSURE For NEMA type 12 enclosure, interfacing air-out and air-in openings are required in the enclosure top. HB16 SERIES 1. Dash lines represent 2. Entire weight of air conditioner is not intended to be supported by the mounting flanges. Slide rails should be installed. 3. Cut-out and duct or gasket required on enclosure for condenser air discharge. 4. Cut-out dimensions INTERNAL MOUNT TOP SURFACE MOUNT INTERNAL MOUNT TO ENCLOSURE For internal top mounting to NEMA type 12 enclosures, slide rails should be used. Cool air blows down. TOP SURFACE MOUNT TO ENCLOSURE For top mounting of air conditioner, interfacing air-out and air-in openings are required in the top of the enclosure. Special filter frame required, consult factory about model specifications. HB30 SERIES 1. Dash lines represent 2. Cut-out dimensions TOP SURFACE MOUNT TOP RECESSED MOUNT TOP SURFACE MOUNT TO ENCLOSURE For top mounting of air conditioner, interfacing air-out and air-in openings are required in the enclosure top surface. TOP RECESSED MOUNT TO ENCLOSURE Cool air blows down. Consult factory when ordering Series 30 RM. Air conditioner is 8.5" standard onto the enclosure.

1. Gasket kit for mounting to enclosure 2. Service cord. 3. Condensate from enclosure drains to bottom pan of unit where it is evaporated by condenser heat. 4. Condensate overflow drain hose 1. Gasket kit for mounting to enclosure 2. Service cord terminated with appropriate plug cap. 3. Condensate drain hose with a P trap 1. Gasket kit for mounting to enclosure 2. Service cord terminated with appropriate plug cap. 3. Condensate drain hose 4. Unit is available surface mounted as shown or in partially recessed mount configuration. AIR CONDITIONERS HB11, HB16, HB30 TOP-MOUNT

TM RCR11 Series 2000-4000 BTU/Hr. (586-1172 Watts) H x W x D: 10.47" (266) x 19" (483) x 21.47" (545) Max Shipping BTU/Hr @ Amps @ BTU/Hr @ Amps @ Amb Temp Weight Model Voltage Hz Phase 131 F/131 F* 131 F/131 F 95 F/95 F* 95 F/95 F F/ C Lbs/Kgs RCR11-0216-G002 STOCK 115 50/60 1 1800/2000 9.0/9.0 1800/2000 8.0/7.4 131/55 95/43 RCR11-0216-G0XX 115 50/60 1 1800/2000 9.0/9.0 1800/2000 8.0/7.4 131/55 95/43 RCR11-0226-G0XX 230 50/60 1 1800/2000 5.1/4.7 1800/2000 4.7/3.9 131/55 95/43 RCR11-0416-G002 STOCK 115 50/60 1 3800/4000 12.9/12.9 3500/3500 11.1/9.9 131/55 107/49 RCR11-0416-G0XX 115 50/60 1 3800/4000 12.9/12.9 3500/3500 11.1/9.9 131/55 105/48 RCR11-0426-G0XX 230 50/60 1 3800/4000 7.1/7.1 3500/3500 5.6/5.0 131/55 105/48 *Because air conditioners provide less cooling at lower operating temperatures, two cooling capacity ratings are listed for each ProAir air conditioner to assist you in your selection. LB14 Series 7000 BTU/Hr. (2051 Watts) H x W x D: 14.75" (375) x 19" (483) x 23.63" (600) Full BTU/Hr @ Max Shipping Load Max Amb Amb Temp Weight Model Voltage Hz Amps Phase Temp F/ C Lbs/Kgs LB14-0715-0XX 115 50/60 15.0 1 5800/7000 125/52 140/64 LB14-0716-0XX 115 60 15.0 1 7000 125/52 135/61 LB14-0725-0XX 230 50 8.0 1 7000 125/52 135/61 LB14-0726-0XX 230 60 7.5 1 7000 125/52 135/61 Most models available with Hz selector, if desired. Contact factory. The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. A single internal wiring change is required for 60 Hz operation. LB16 Series 10000 BTU/Hr. (2930 Watts) H x W x D: 15.72" (399) x 19" (483) x 25.19" (640) Full BTU/Hr @ Max Shipping Load Max Amb Amb Temp Weight Model Voltage Hz Amps Phase Temp F/ C Lbs/Kgs LB16-1016-0XX 115 60 20.0 1 10000 125/52 140/64 LB16-1025-0XX 230 50 10.0 1 10000 125/52 140/64 LB16-1026-0XX 230 60 10.0 1 10000 125/52 140/64 Most models available with Hz selector, if desired. Contact factory. The 50/60 Hz units, because of the addition of an autotransformer, cost more than straight 60 Hz models. Units wired for 50 Hz operation when shipped. A single internal wiring change is required for 60 Hz operation. RCR11 LB14 LB16 Ambient air flow Clean air flow AIR CONDITIONERS RCR11, LB14, LB16 RACK-MOUNT