TA WASTE VENT WALL MOUNTED WATER CLOSET WITH WC ELONATED BOWL AT ADA HEIHT " " " UR LAV SK SH TMV MSB WMB WASHIN MACHINE SUPPLY " /" /" /" AND DRAIN FIXTURE NOTES: WALL HUN, WALL OUTLET, VITREOUS CHINA HIH EFFICIENCY URINAL WITH ELONATED RIM 0x8 / BARRIER FREE VITREOUS CHINA LAVATORY WITH CONCEALED ARM CARRIERS DOUBLE BOWL STAINLESS STEEL THERMOSTATIC MIXIN VALVE MOP SERVICE BASIN HOT WATER " /" /" /" /" /" /" SHOWER DRAIN " /" /" /" /" ES EMERENCY SHOWER COLD WATER FLOOR MOUNTED WATER CLOSET WITH WC ELONATED BOWL ADA COMPLIANT " " " /" /" /" /" SK WALL HUN, STAINLESS STEEL LAVATORY /" /" /" /" VANDAL RESISTANT EWC /" /" /" ELECTRIC WATER COOLER " " /" /" MSS MOP SERVICE SINK " " /" /" NFWH NONFREEZE WALL HYDRANT /" PLUMBIN FIXTURE SCHEDULE TEMP WATER MANUFACTURER AND MODEL NUMBER " AMERICAN STANDARD MODEL 7.0 "AFWALL". PF FLUSH VALVE TOILET, VITREOUS CHINA, WALL MOUNTED, DIRECTFED SIPHON JET ACTION, /" INLET SPUD, OPEN FRONT SOLID WHITE PLASTIC SEAT. PROVIDE SLOAN ROYAL OPTIMA MODEL. V DC SENSOR ACTIVATED FLUSHOMETER. AMERICAN STANDARD MODEL 0.00 "WASHBROOK".0 PF, VITREOUS CHINA, FLUSHIN RIM, ELONATED " RIM FROM FINISHED WALL, /" TOP INLET SPUD. PROVIDE SLOAN ROYAL MODEL 80ESS V DC SENSOR ACIVATED FLUSHOMETER. AMERICAN STANDARD MODEL 0. "COMRADE" WALL HUN VITREOUS CHINA LAVATORY, WITH CONCEALED ARM SUPPORT, " CENTER FAUCET HOLES. PROVIDE ZURN MODEL Z80XLH POLISHED CHROMEPLATED CAST BRASS FAUCET WITH " WRIST BLADE HANDLES AND HANDICAP RID DRAIN. ADVANCE TABCO "REALINE" DOUBLE COMPARTMENT SCULLERY SINK # 9. AUE TYPE 0 SS WITH " HIH BACKSPLASH. SS /8" DIAMETER LES. PROVIDE WITH TABCO # K HEAVY DUTY PRERINSE FAUCET. B SHOCK S.S. RECESSED ARRESTOR AS RILL OUTLET BOX WESTERN NATURAL AS PRODUCTS LTD. MODEL R00SS STAINLESS STEEL RECESSED AS OUTLET BOX /" /" JAY WITH R. LOCKABLE SMITH MODEL DOOR. 00 P.D.I. SIZE A FIXTURE UNIT RATIN. ABBREVIATIONS: ACCESS DOOR ABOVE FINISH FLOOR COLD WATER ELECTRIC WATER COOLER FLOOR DRAIN HOSE BIBB HOT WATER ENERAL NOTES. FIELD COORDINATE ALL PIPE RUNS BEFORE FABRICATION AND INSTALLATION. NO EXTRAS SHALL BE PERMITTED FOR REROUTIN, REFABRICATION, RESTOCKIN OR REMOVAL OF INSTALLED WORK DUE TO COORDINATION WITH BUILDIN STRUCTURE, WORK OF OTHER TRADES OR EXISTIN BUILDIN COMPONENTS. DRAWINS ARE SCHEMATIC AND, PIPIN RUNS DO NOT SHOW ALL NECESSARY CHANES IN ELEVATION OR OFFSETS REQUIRED FOR A COMPLETE INSTALLATION. PROVIDE ALL PIPE OFFSETS AS REQUIRED FOR THE INSTALLATION OF THE RUNS SHOWN ON PLANS.. PLANS AND SECTIONS DO NOT SHOW COMPLETE VALVE ARRANEMENT FOR PIPIN TO EQUIPMENT. SEE FLOW SCHEMATICS AND DETAILS.. PROVIDE DRAINS AT ALL WATER PIPIN LOW POINTS. PITCH PIPIN TO DRAIN.. THE BUILDIN HAS A SEISMIC DESIN CATEORY OF C, IS SEISMIC USE ROUP III, AND HAS AN IMPORTANCE FACTOR OF.. ADVANCE TABCO SS WALL MOUNT LAVATORY # 7PS9, 0"x"x" BOWL. PROVIDE WITH INTERAL SS WALL BRACKET. HWR HOT WATER RETURN SAN SANITARY DRAINAE ABOVE RADE PROVIDE WITH TABCO #K9 FAUCET, WITH WRIST BLADE HANDLES, SS BASKET STRAINER, AND AUTOMATIC SOAP DISPENSER. I E INVERT ELEVATION SAN SANITARY DRAINAE BELOW RADE PROVIDE ZURN # FDPVSCP ADJUSTABLE SHOWER DRAIN ASSEMBLY WITH CHROME PLATED STRAINER. LAV LAVATORY MV MIXIN VALVE V VENT PIPIN NIC NOT IN CONTRACT COLD WATER HOT WATER BRADLEY TMV MODEL S90/T/B WITH A FLOW CAPACITY OF TO PM. PROVIDE INTERAL NFWH NONFREEZE WALL HYDRANT STRAINER, INLET CHECKSTOPS, OUTLET DIAL THERMOMETER AND WALL MOUNTIN BRACKET. HOT WATER RETURN NTS NOT TO SCALE CA COMPRESSED AIR PIPIN ELKAY MODEL LVRC8WS NO LEAD, VANDAL RESISTANT, WALL MOUNT ELECTRIC WATER COOLER,.0 FULL PDI PLUMBIN DRAINAE INSTITUTE LOAD AMPS, 70 WATTS. PROVIDE WATERSENTRY FILTER SYSTEM. BA BREATHIN AIR PIPIN SA SHOCK ARRESTER SK SINK LP LP AS PIPIN UARDIAN MODEL DRENCH SHOWER. PROVIDE WITH UARDIAN 800 THERMOSTATIC MIXIN VALVE. TYP TYPICAL WPCO CLEAN OUT WALL PLATE THW TEMPERED HOT WATER CLEAN OUT CLEAN OUT DECKPLATE OR UR URINAL FIAT MODEL MSB, "x"x0" PRECAST TERRAZZO SERVICE BASIN. PROVIDE ADVANCE TABCO MODEL CLEANOUT TO RADE K0 CHROME PLATED SERVICE FAUCET WITH VACUUM BREAKER & INTERAL STOPS. PROVIDE 0" HOSE. V VENT HOSE BIBB OR WALL HYDRANT VTR VENT THRU ROOF FLOOR DRAIN ELKAY WALL MOUNTED STAINLESS STEEL "SERVICE SINK" #ESSB0C. FURNISH COMPLETE WITH " BUCKET HOOK FAUCET W WASTE UNION #LK907BR07LH AND CAST IRON PTRAP #LK7. WC WATER CLOSET SHUTOFF VALVE WH WATER HEATER CHECK VALVE WOODFORD MODEL B7 ANTISIPHON AUTOMATIC DRAININ WALL HYDRANT COMPLETE WITH NONFREEZE WCO WALL CLEANOUT TYPE INTERAL VACUUM BREAKER, LOOSE KEY OPERATOR AND HINED LOCKIN COVER. OPERATIN RELIEF VALVE ROD ASSEMBLY 0/" LON. PROVIDE @ '8" ABOVE FINISHED FLOOR. STRAINER UY RAY (IPS CORPORATION) MODEL B00 A. STEEL WASHIN MACHINE SUPPLY AND DRAIN BOX WITH INDIVIDUAL /" HOT AND COLD TOP WATER SUPPLY VALVES AND " WASTE.. ALL FIXTURES SHALL HAVE INDIVIDUAL ANLE STOPS, TRAPS AND ESCUTCHEONS.. VERIFY MOUNTIN HEIHTS WITH ARCHITECTURAL ELEVATIONS.. WHEELCHAIR ACCESSIBLE SINKS AND LAVS SHALL HAVE OFFSET TRAPS. ANLE STOPS, SUPPLIES AND TRAPS SHALL BE COVERED WITH TRUEBRO "LAV UARD" OR EQUAL PROTECTIVE COVERIN. AMERICAN STANDARD MODEL.00 "MADERA FLOWISE". PF FLUSH VALVE TOILET, VITREOUS CHINA, FLOOR MOUNTED, DIRECTFED SIPHON JET ACTION, /" INLET SPUD, OPEN FRONT SOLID WHITE PLASTIC SEAT. PROVIDE SLOAN ROYAL OPTIMA MODEL. V DC SENSOR ACTIVATED FLUSHOMETER. ABV AD AFF CO CODP COT COWP CW DN DW EWC FD HB HW ABOVE CLEAN OUT CLEAN OUT DECK PLATE CLEAN OUT TO RADE CLEAN OUT WALL PLATE DOWN DRAWIN PLUMBIN SYMBOLS: A PRESSURE AUE THERMOMETER SHOCK ARRESTER TRAP ELBOW UP ELBOW DN BRANCH OFF TOP TEE BRANCH OFF BOTTOM PRESSURE REDUCIN VALVE COMPRESSED AIR QUICK DISCONNECT BALANCE VALVE DRAIN SCHEDULE THERMAL EXPANSION TANK SCHEDULE HOSE REEL SCHEDULE TA MANUFACTURER AND MODEL NO. FD FD ENERAL SERVICE FLOOR DRAIN WITH NICKEL BRONZE STRAINER. MEDIUM DUTY FLOOR DRAIN WITH CAST IRON BAR RATE. JAY R. SMITH " MODEL 00 CAST IRON FLOOR DRAIN WITH " ROUND ADJUSTABLE NICKEL BRONZE STRAINER. (NOTE ) JAY R. SMITH MODEL 0 " CAST IRON FLOOR DRAIN WITH 8 /" DIAMETER CAST IRON BAR RATE STRAINER. NOTES:() PROVIDE JAY R. SMITH MODEL 90 QUAD CLOSE TRAP SEAL DEVICE. TA ET TYPE VERTICAL ASME, FLEXIBLE DIAPHRAM, FOR POTABLE WATER TANK VOLUME (AL.) MAX. ACCEPT. (AL.) MAX. TEMP. ( F) CIRCULATOR PUMP SCHEDULE MAX. PRESS. (PSI).. 0 0 MAKE & MODEL WESSELS TTA SIZE 0"Ø x " H TA WHR AHR WALL HUN HAND CRANK WATER HOSE REEL WITH 70' /" HOSE. WALL HUN, SPRIN RETURN, ENERAL COMPRESSED AIR HOSE REEL. MANUFACTURER AND MODEL NUMBER HANNAY REELS MODEL N880.B HEAVY DUTY SPRIN REWIND HOSE REEL. PROVIDE 70' OF /" WATER HOSE WITH BACKFLOW PREVENTION DEVICE. PROVIDE " SS FLEXIBLE HOSE FROM HOSE BIB TO REEL. COXREELS MODEL EZPLP0 SPRIN HOSE REEL WITH 0' OF /8" HOSE. PRESSURE RATIN 00 PSI. PHASE TA SERVICE TYPE CAPACITY ELECTRICAL MAKE & MODEL CP HOT WATER CIRCULATION 0 BRONZE PM @ ' TDH, /0 HP, TACO MODEL CANNED 0 RPM //0 00B ROTOR AHR WALL HUN, SPRIN RETURN, BREATHIN AIR HOSE REEL. HANNAY REELS MODEL # FHN7 TR HM, HEAVY DUTY SPRIN REWIND HOSE REEL. PROVIDE 0' OF /8" BREATHIN AIR HOSE. PRESSURE RATIN 000 PSI. MOUNT AT 8'0" AFF. DW. BY: DW :
ENERAL NOTES. ALL PLUMBIN WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE UNIFORM CONSTRUCTION CODE (UCC), AND THE INTERNATIONAL PLUMBIN CODE (IPC 009).. ALL UNDERSLAB SANITARY PIPIN SHALL BE PITCHED AT /8" PER FOOT MINIMUM.. REFER TO ARCHITECTURAL PLANS FOR DIMENSIONED WALL AND CHASE LOCATIONS. COORDINATE PIPIN STUB LOCATIONS WITH DIMENSIONED PLANS.. ALL SANITARY UNDERSLAB LATERAL PIPIN SHALL BE A MINIMUM NOMINAL DIAMETER OF ".. INVERT ELEVATIONS REFERENCE FINISHED FLOOR.. ALL SANITARY / WASTE PIPIN SHOWN ON THIS DRAWIN IS LOCATED UNDER THE FLOOR SLAB UNLESS NOTED OTHERWISE. KEYED NOTES. CONNECT " SANITARY TO.C. PROVIDED TRENCH DRAINS, COORDINATE CONNECTION WITH.C. 0 00 0 0 0 0 07 08 C0 09 PHASE 7 0 0 DW. BY: DW : P. /8" = '0"
ENERAL NOTES. ALL PLUMBIN WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE UNIFORM CONSTRUCTION CODE (UCC), AND THE INTERNATIONAL PLUMBIN CODE (IPC 009).. SEE PLUMBIN FIXTURE SCHEDULE DRAWIN P.0 FOR INDIVIDUAL SANITARY AND VENT CONNECTION SIZES. KEYED NOTES. PLUMBIN VENTS TO BE FULLY INSTALLED THOUH ROOF. CAP THE VENT. PROVIDE FT OF PIPIN BELOW ROOF. 0 00 0 0 0 0 07 08 C0 09 PHASE 0 0 7 DW. BY: DW : P. /8 = '0"
ENERAL NOTES. ALL PLUMBIN WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE UNIFORM CONSTRUCTION CODE (UCC), AND THE INTERNATIONAL PLUMBIN CODE (IPC 009).. SEE PLUMBIN FIXTURE SCHEDULE DRAWIN P.0 FOR INDIVIDUAL SANITARY AND VENT CONNECTION SIZES. KEYED NOTES. PROVIDE WALL MOUNTED REULATOR BOX WITH SERVICE VALVE, PRESSURE REULATOR AND PRESSURE AUE. ALL COMPONENTS SHALL BE RATED FOR 000 PSI MINIMUM. CONNECT TO JIC MALE FITTIN ON BREATHIN AIR MODULE. M0 M0 PHASE M0 DW. BY: DW : P. /8 = '0"
P FACP ATS A. ALL PLUMBIN WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PLUMBIN CODE OF THE UNIFORM CONSTRUCTION CODE (UCC), AND THE INTERNATIONAL PLUMBIN CODE (IPC 009). " CW, "HW, /"HWR AND "N INTO MEZZANINE. PROVIDE NFWH. NO PIPIN REQUIRED UNDER PHASE. /" CW DOWN TO HOSE REEL. P P & P STACKED INTERATED SWITCHBOARD. AHU (PHASE ) B. REFER TO FIXTURE SCHEDULE ON DRAWIN P.0 FOR PIPIN CONNECTION SIZES TO INDIVIDUAL FIXTURES. /" HW & CW DOWN TO EMERENCY SHOWER MIXIN VALVE. PROVIDE /" HW & CW DN TO WASHIN MACHINE SUPPLY BOX. NOT USED. PROVIDE () /" WATER CONNECTIONS TO EAR EXTRACTOR. COORDINATE CONNECTION HEIHTS WITH C AND OWNER. 7 " COMPRESSED AIR DOWN COLUMN TO AIR HOSE REEL. COORDINATE MOUNTIN HEIHT OF AIR HOSE REEL WITH C. /" COMPRESSED AIR DROP. PROVIDE REULATOR WITH FEMALE QUICK CONNECT COUPLER @ '0" AFF. AHU (PHASE ) 9'" MAX WATER SERVICE AREA COORDINATE WITH FIRE PROTECTION CONTRACTOR /" CW DN TO TRUCK FILL. /" COMPRESSED AIR DROP. PROVIDE REULATOR WITH FEMALE QUICK CONNECT COUPLER @ '0" ABOVE WORK SURFACE OF WORK BENCH. PROVIDE RILLE OUTLET BOX. NO PIPIN REQUIRED UNDER PHASE. /" BREATHIN AIR DOWN TO AIR HOSE REEL. PROVIDE BALL VALVE AT CONNECTION TO AIRHOSE REEL. PROVIDE SEPARATE REULATOR AND SHUT OFF VALVE FOR DEDICATED AS SUPPLY TO ENERATOR. REULATOR SHALL BE SET TO IN. WC. P. /" ='0" 0 00 0 0 0 0 07 08 C0 09 P. PHASE 0 0 7 DW. BY: DW : P. /8" = '0"
HOSE REEL /" CW CONTROL VALVE '0" FINISHED FLOOR NTS NOTE: REFER TO ARCHITECTURAL DRAWINS FOR MOUNTIN HEIHT OF HOSE REEL. " TO POTABLE WATER SYSTEM FIRE PROTECTION SERVICE EQUIPMENT BY OTHERS BALL VALVE (TYP.) " STRAINER " RPZ BACKFLOW ASSEMBLY RPZ DRAIN (AIR AP) 8" " DRAIN. PIPE TO BUILDIN EXTERIOR PRESSURE AUE PRESSURE REDUCIN VALVE NO SCALE /" /" HWR AQUASTAT (TYP.) /" " HW " HW BRACE " CW " CW /" RPZ FOR BOILER MAKEUP CONT. BY HVAC /" /" CW BALL VALVE STEEL COLUMN ELBOW REMOVE HANDLE REDUCER (TYPICAL) TMV /" HOSE THREAD FITTIN PHASE /" INDIRECT FIRED STORAE WATER HEATER BY HVAC THERMOSTATIC MIXIN VALVE HOSE END DRAIN VALVE (TYPICAL) '0" FINISHED FLOOR MEZZANINE FLOOR DW. BY: DW :