SILO PROTECTION SYSTEMS

Similar documents
MICROSENSE FLOW SWITCH

Microwave Doppler Flow Switch. Installation & Operation Manual

Fill Point, Level Gauges, and Control Range

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Installation, Operating and Maintenance Manual

Pump-Down Controller MODEL 4052

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

Process Alarm Module RTA 421

Pump-Up Controller MODEL 4062

PARTICULATE EMISSION MONITORING

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

ACL TC 200 TEMPERATURE CONTROLLER

USER MANUAL & MAINTENANCE GUIDE OG OO

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

MTRA-FSP Level Control Relay. Installation & Operation Manual

Process & TeMPerATUre UniversAl input DigiTAl MeTers

SAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

WARNING FIRE DOOR CLOSING

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Intelligent Security & Fire Ltd

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Service manual. Type: TD25. Contents

APM110 LOW AIR VELOCITY ALARM

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Axiom Technologies L.L.C Telephone: Pennbright Dr., Suite 220 Fax: XP7 USER S MANUAL

The EN54 Part 2 & 4 Fire System

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

EXTINGUISHING AGENT RELEASE MODULE

GAS SUPRESSION CONTROL PANEL:

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

IR FLAME DETECTOR RIV-601/F

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Installation & Start UP

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Belt Conveyor Safety Monitoring Devices

The next generation thermometer from the global leader

Pneumatic Heat Press. Revision: 3 Operators Manual

DISABLED TOILET / EMERGENCY ASSISTANCE ALARMS

DCS-100. intelligent damper control & monitoring system

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

the next generation thermometer from the global leader

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF


INSTALLATION MANUAL. ACL TC 200 Pilotless Burner Control System

ANALOX 3000 Carbon Monoxide Monitor

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

IJ3000 IJ3000 Flushing System N Revision B Installation Instructions Page 1 of 10

INSTRUCTION MANUAL AMS WATER MANAGEMENT SYSTEM (AMS-WMS 230V) INSTRUCTION MANUAL AMS WMS 230V Manual Issue 1 15/10/09 Page 1 of 15

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

DIGITAL ALARM UNIT Model ALU-AP

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

Flostop TS D7E and A8E. Operation Manual

Flopurge TS. Operation Manual

Alarm Tone Generator Model AG17

FCHM Hydromatic Pump Control Module

Specification , July 2015

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

icountms Range Fluid Condition Monitoring Moisture Sensors

Duct and Rough Service Carbon Monoxide Sensor

Intelligent Security & Fire Ltd

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

WD7664 / WD7663 Maxon Burner. Ellis Whisper Dryer Installation & Start UP

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Version 1.03 January-2002 USER S MANUAL

FIRE ALARM CONTROL PANEL FVC01-08

Instruction Manual August sitrans CU 02

LEAKSTOPPER 1 Single zone water leak detection system

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

GV Standard X-Vent Operation and Maintenance Manual

ZXSe Range Data Sheet

TotalPac 3 Firecyle III Deluge Remote controlled system

EMERGENCY ASSISTANCE ALARMS

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

Dual Tower Heat Reactivated Desiccant Air Dryer

FUSION ALARMS TROUBLESHOOTING GUIDE CURRENT LIMIT VOLTAGE LIMIT

Premier Hazard STC Instructions

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Annexure - 1. Detectors: Fire Alarm Control Panel :

Analog Room Pressure Monitor RPC Series

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Ultrasonic Point Level Switches

CLEANROOM MONITOR CR3A Network - Installation Instructions

Transcription:

SILO PROTECTION SYSTEMS HYCONTROL LIMITED, Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, Tel : 01527 406800 Fax : 01527 406810 Email : sales@hycontrol.com Website : www.hycontrol.com

SILO PROTECTION PANEL SPECIFICATION HYCDP500A Silo protection is required to overcome the problems of overfill and over pressurisation of a storage silo during the pneumatic delivery of powder or dry bulk products such as cement. The panel HYCDP500A is designed to be used in conjunction with four other items which, in total, provide the silo protection system. The primary elements are : Pressure sensor FLEX 500 High Level sensor ME11series Pressure relief valve Continuous level gauge Optional equipment : Fill pipe lock off Fill pipe shut off valve This panel will monitor the pressure while filling the silo and give a continuous measurement of contents as well as an ultimate high level alarm. Both the level and pressure sensors are used to initiate audio / visual alarms and if the optional shut off valve is used, shut off the inlet to the silo. The ability to delay closure of the valve from a high level condition is also included. Display Panel mechanical configuration: IP65 GRP enclosure suitable for mounting outdoors. Multi tone siren (IP65) mounted on the panel side. Large flashing alarm beacon mounted on top of the panel. Supply voltage 110v or 230 v 50 hz (for alternative options please ask). Large bar graph and numeric 4 digit display of silo pressure. Large bar graph and numeric 4 digit display of silo continuous level. IP65 protection cover for bar graph display. Key operated silo enable switch for authorised personnel only. Key operated switch for authorised personnel to mute and acknowledge alarm condition if reached. Integral panel heater for frost protection Ground level test facility for level sensor. Ground level test facility for pressure sensor (see note 1) Indicator warning lamps to show : Level sensor fault Pressure sensor fault High level alarm High pressure alarm Power to panel Ok to fill condition Early high level warning

SILO PROTECTION PANEL HYCDPS500A te The above panel is a standard layout that has been designed for operators to view the important parameters when filling a silo. The use of high visibility large LEDS and full 101segment bar graph indicators mean it can be seen clearly at a glance if either the level or pressure is in a high condition.

te 1. There are many silo protection systems available on the market but none that can carry out a true ground level test (GLT) of the silo pressure sensor, which it could be argued is the most important sensing element of the system. Hycontrol is the only company which can test the sensor over its full operating range, clean the sensor, test the output integrity and also confirm if the air to the filters is on (see silo protection brochure). 2. The panel configuration and display is designed to be simple to read and simple to operate using the simple flow diagram attached. 3. Other panel options are available if required please consult Hycontrol for further information. 4. This panel and associated equipment is for use in non-hazardous area locations only. For ATEX certified equipment consult Hycontrol Ltd. HYCDPS500A PANEL OPERATING PROCEDURE The system is designed to provide a safe and practical solution to the risk of over filling or over pressurising a silo, during a delivery from a road tanker. The procedure for receiving a delivery is detailed below. On arrival the tanker driver reports to the site person responsible. The appropriate silo s panel is activated using a key. Without this key the valve in the discharge pipe will not be capable of opening and no delivery will be possible. Once the key has activated the panel, and no alarms are in operation, the driver must press the GROUND LEVEL TEST button and release it. The High Level and High Pressure Alarm lamps and the siren should be active for 5 seconds after the Sensor Test button has been pressed. If the sensors pass the Test the White Ready to Fill lamp will be illuminated, indicating that the discharge valve has opened and delivery can proceed. If either the Level or Pressure sensor fail the test then the appropriate Sensor Fault lamp will be on and the Ready to Fill lamp will be off. If the Level Sensor has failed the test, the Sensor Fault lamp will be flashing. If the Pressure Sensor has failed the test, the Sensor Fault lamp will be on permanently or flashing depending upon the reason for failure.

Refer to the instruction manual for details on Troubleshooting and Fault finding. It will be necessary to determine the reason for failure and rectify it before the delivery can proceed. Reset the system using the key switch and start the procedure again. If the Ready to Fill lamp is illuminated, the delivery can proceed. If a High Level condition is reached, the High Level lamp will illuminate, the siren will sound and the Red beacon will flash. A countdown timer will close the discharge valve after 30 seconds, giving the driver time to cease filling and clear down his line. The siren can be muted using a key held by the site personnel. The High Alarm condition will remain until the level in the silo falls. If a High Pressure condition is reached, the High Pressure lamp will illuminate, the siren will sound and the Red beacon will flash. The discharge valve will be closed immediately. The siren can be muted using a key held by site personnel. The High Pressure alarm will stay on until the pressure falls to a safe value. When delivery is completed the system should be disabled by removing the key from the panel. The bar graph showing level and pressure will remain active but no alarms will be enabled and no deliveries will be possible until the panel is activated again using the key. Any problems contact technical assistance on 01527 406800. Standard protection components PANEL - HYCDP500A HIGH LEVEL PROBE - ME11ADT1000MDG PRESSURE SENSOR FLEX 500 PRESSURE RELIEF VALVE PRV350 (Adaptor may be required POA) LEVEL GAUGE TDR NORMALLY CLOSED 3 BUTTERFLY VALVE NORMALLY CLOSED 4 BUTTERFLY VALVE PILOT valve for above FILL PIPE LOCK OFF c/w microswitch

Enable Silo Filling System using Keyswitch Silo Protection Logic Thursday, September 22, 2005 Is Silo Ready lamp on Reset the System and Start Procedure again Are any alarms active DO NOT PROCEED, SEEK ASSISTANCE Press GLT button Did all Tested functions complete successfully Is a Sensor Fault lamp flashing Press Lamp Test button Did all Lamps light Proceed to fill Silo Check sensor and wiring Change failed lamp Alarms Sound Reset the system and Start Procedure again Reset the System and Start Procedure again Reset the System and Start Procedure again If problem persists contact Hycontrol for Service and Support A Pressure alarm will result in the fill pipe closing immediately. A level alarm will delay closure of fill pipe for 10 seconds allowing lines to be cleared Mute Siren using Keyswitch Complete shut down procedure Disable Silo Filling System using Keyswitch

Silo protection pressure sensor FLEX 500 This sensor monitors the pressure in the silo during fill conditions and transmits a 4-20mA signal back to a control panel to form an essential part of the silo protection system. The unit can be used with a standard Hycontrol silo protection panel or with other manufacturer s equipment capable of powering a 4-20mA transmitter. The FLEX 500 is unique in that it can be tested while in the silo. A true functional test to guarantee it is working satisfactorily, before a powder delivery takes place can be initiated at the press of a button. The test can detect if the sensor is blocked, damaged or faulty and also completes a selfclean operation every time the button is pressed. As this test utilises the same air as the filters it will also detect if the supply to the filters is not on. Performance Specification Measuring Range : 0 100 mbar (0 1000 inches H 2 0 Accuracy : +/- 0.25% full scale Hysteresis : < +/- 0.25% full scale Repeatability : < +/- 0.25% full scale Hardware Specification Sensor power supply : 24 VDC 2 wire loop powered GLT power supply : 110 VAC 50 Hz (24vdc optional) Air supply for GLT : 50 psi min 150 psi max (see note 1) Analogue output : 4-20 ma Ambient Temp range : -20 to +70 deg C Enclosure : IP67 Robust Glass filled Nylon Electrical entry : M20 x 1.5mm cable entry Process connection : 1 BSPP as standard other options available FLEX 500 Pressure sensor with ground level test facility to determine if the sensor is damaged, blocked or faulty. It also detects if the air to the filters is on.

SILO PRESSURE RELIEF VALVE The PRV350 is a combined pressure and vacuum relief valve and is designed to protect silos from the effects of over pressurisation during either a fill or empty condition. The Pressure relief valve can exhaust up to 13000m 3 / hour and is available with a wide range of mounting options. Sized for 13000m 3 / hour outflow Sized for 5000m 3 / hour inflow Quick release cover External springs high tolerance to dust Fully compliant with HSE guidelines Suitable for pressures up to 900mm w.g. (Standard pressure setting is 500mm w.g.) Suitable for vacuum up to 250mm w.g. Stainless steel construction body EPDM gasket material Optional proximity switch for under or over-pressure Optional adaptors available for new and retrofit requirements.

SILO HIGH LEVEL WARNING SENSOR The prime function of this device is to protect the silo from overfilling and blinding the filters. These are available in a wide range of technologies but the most commonly used is capacitance. This is a universal technology for both liquids and solids and can detect a wide range of products. All Hycontrol level probes incorporate the ground level test function. The level probe is available in a rigid rod or flexible cable version depending upon the range required. ME11ADT0250MDG available in lengths up to 1.5m ME50ADT3000MDG available in lengths up to 3.0m Die-cast Aluminium Body/Electrical Housing IP65 housing protection Screw terminal electrical connection 2 x M20 electrical entries Failsafe HI / LO Selectable Power consumption 2w 1" BSP process connection Stainless steel and UPE probe Probe length variable -20 to +80 deg C operating temperature 1 SPDT set of contacts. 5A rating at 240Vac or 30Vdc Adjustable time delay 0 to 6 seconds Integral sensitivity adjustment with adjustment indicator Unit in contact with material indicator Integral ground level test facility 110/220Vac supply voltage