SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS

Similar documents
SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A53HW TAN/TAG-A70HW CONTENTS

Part 3 Troubleshooting

Room Air Conditioner CONTENTS CS-E9BKP CU-E9BKP5 CS-E12BKP CU-E12BKP5. Order No: MAC C2

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

Owner's Manual TABLE OF CONTENTS

YC ON-OFF SERIES. Service Manual

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

Service Manual. Room Air Conditioner Split Wall-Mounted Type. Applies to: HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1

OWNER S MANUAL VMH 09/12/18/24

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

Air Conditioner CONTENTS CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU. Order No: MAC C1

DUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)

Air Conditioner CONTENTS

FLOOR CONSOLE / UNDER CEILING DUAL type

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

DESIGN & TECHNICAL MANUAL

Owner s Manual TABLE OF CONTENTS

Ductless Split Air Conditioner

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

TECHNICAL DATA & SERVICE MANUAL

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-10, 13, 18, 24, 30BKS-HK

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

II PCV1 Features

VMI-1102-A SERVICE MANUAL AIRCONDITIONER DC INVERTER MULTI TYPE MSV1I-09HRDN1-M TAS-09MVHN TAS-12MVHN INDOOR VERTU DC INVERTER MULTI SERIES

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

SERVICE MANUAL SPLIT WALL-MOUNTED TYPE MODELS MWCOHC30S/MRCOHC30AS MWCOHC36S/MRCOHC36AS

Owner s Manual TABLE OF CONTENTS

KSD-35 DR11 KUE-35 DVN11

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

CASSETTE type INVERTER MULTI AIR CONDITIONER

Part 5. Troubleshooting. 1. Normal Air Conditioner Phenomenon Air Conditioner Protection in Common

SPLIT SYSTEM AIR CONDITIONER

Operating Instructions Air Conditioner

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

COLDWAVE. Portable Air Conditioner. Model MPPD-12CRN BTU/h 110V/1Ph/60Hz R410A

RAS-07EKH/RAS-07EAH RAS-09EKH/RAS-09EAH

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

CASSETTE TYPE. AUT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N KEEP THIS MANUAL FOR FUTURE REFERENCE AM PM

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: MCAF72R5TA- MCAF92R5TA- MCAF122R5TA-

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

Technical Manual of AUX Air Conditioner CONTENTS. Product Specification...1. Refrigeration Diagram...3. Introductions of Installation.

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

Operating Instructions Air Conditioner

Room Air Conditioner Service and Parts Manual

OPERATION MANUAL. Wireless Remote Controller Kit

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

INDOOR UNIT/OUTDOOR UNIT

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

AIR CONDITIONER (SPLIT TYPE)

Operating Instructions Air Conditioner

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

DESIGN & TECHNICAL MANUAL

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

F SERIES ON-OFF SERIES. Service Manual 2016

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

INDOOR UNIT/OUTDOOR UNIT

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL

INDOOR UNIT/OUTDOOR UNIT

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Cassette type Duct type Ceiling type INVERTER AO* G45LETL AO* G54LETL

KTIR AIR CONDITIONER SERIES TROUBLESHOOTING

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

INDOOR UNIT/OUTDOOR UNIT

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

Owner s Manual Super-Slim Four-Way Cassette

TAC-09CHSA/*** TAC-12CHSA/*** TAC-18CHSA/*** TAC-24CHSA/*** SERVICE MANUAL WALL MOUNTED SPLIT-TYPEAIR CONDITIONERS. No.TE1307.

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

3. INDOOR UNIT OPERATION

Transcription:

SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS SPECIFICATION... 1 FUNCTIONS... 5 SERVICE FUNCTION EXPLANATION... 7 OPERATION DETAILS... 8 TROUBLESHOOTING GUIDE... 13 PERFORMANCE CURVE DIAGRAM... 19 ELECTRIC CIRCUIT DIAGRAM... 22 EXPLODED VIEW (INDOOR UNIT)... 24 EXPLODED VIEW (OUTDOOR UNIT)... 25 PARTS LIST (INDOOR UNIT)... 27 PARTS LIST (OUTDOOR UNIT)... 28

SPECIFICATION Unit INDOOR TAN-A28FWIS OUTDOOR TAG-A28FWIS Cooling Capacity BTU/h 9,000(5,700-10,000) Heating Capacity BTU/h 11,000(5,700-12,500) Moisture Removal L/h 1.6 phase Single Power source V 230 Hz 50 OUTLET SIDE VIEW TOP VIEW Airflow Method INTAKE Air circulation (at High) 3 m/min Cooling ; Heating ; 8.4 8.7 Input Electrical Data Running Current Starting Current Piping Connection Port (Flare piping) Pipe Size (Flare piping) Inner diameter Drain hose Length Length Power Cord Number of core-wire Height Dimensions Width Depth Net Weight W A Cooling ; Heating ; Cooling ; Heating ; 780 860 3.8 4.2 A inch 4.2 L ; Half Union 1/4'' L ; 2-way valve 1/4'' inch G ; Half Union 3/8'' G ; 3-way valve 3/8'' inch L (liquid side) ; 1/4'' L (liquid side) ; 1/4'' inch G (gas side) ; 3/8'' G (gas side) ; 3/8'' mm 14 m 0.6 m 1.4 2 core-wire/ 1 mm mm 265 545 mm 795 710 mm 182 255 kg 8.3 28.0 1

SPECIFICATION Unit INDOOR TAN-A28FWIS OUTDOOR TAG-A28FWIS Air Circulation Heat Exchanger Refrigerant Control Device Refrigerant (R410A ) Thermostat Air Filter Parts Provided Type Motor Type Rated Output W g (oz) Cross-flow Fan Induction (4-pole) Propeller Fan Induction (6-pole) 20 20 Plate fin configuration,forced draft 19.5FPI Electronic Control 19.5 FPI Capillary Tube 860(30.3) Timer Real time dual ON/OFF 7-hour OFF Mold-proof 1 Mounting plate 2 Remote controller 3 Battery (2 pcs.) 4 Remote controller holder 5 Screw cap (2 pcs.) 6 Drain elbow 7 Vibration proof rubber (4 pcs.) 8 Air clean filter (2 pcs.) (Bamboo Charcoal/Photo-catalytic anti-odor filters) Specifications are subject to change without notice. 2

SPECIFICATION Unit INDOOR TAN-A32FWIS OUTDOOR TAG-A32FWIS Cooling Capacity BTU/h 11,000(5,700-12,000) Heating Capacity BTU/h 13,500(5,700-14,500) Moisture Removal L/h 1.7 phase Single Power source V 230 Hz 50 OUTLET SIDE VIEW TOP VIEW Airflow Method INTAKE Air circulation (at High) Input Electrical Data Running Current Starting Current Piping Connection Port (Flare piping) Pipe Size (Flare piping) Inner diameter Drain hose Length Length Power Cord Number of core-wire Height Dimensions Width Depth Net Weight 3 m/min W Cooling ; Heating ; 9.8 10.3 Cooling ; 1,000 Heating ; 1,080 Cooling ; 4.8 A Heating ; 5.2 A inch 5.2 L ; Half Union 1/4'' L ; 2-way valve 1/4'' inch G ; Half Union 3/8'' G ; 3-way valve 3/8'' inch L (liquid side) ; 1/4'' L (liquid side) ; 1/4'' inch G (gas side) ; 3/8'' G (gas side) ; 3/8'' mm 14 m 0.6 m 1.4 2 core-wire/ 1 mm mm 265 545 mm 795 710 mm 182 255 kg 8.3 29.5 3

SPECIFICATION Unit INDOOR TAN-A32FWIS OUTDOOR TAG-A32FWIS Air Circulation Heat Exchanger Refrigerant Control Device Refrigerant (R410A ) Thermostat Air Filter Type Motor Type Rated Output W g (oz) Cross-flow Fan Propeller Fan 20 20 Plate fin configuration,forced draft 19.5FPI 16.9 FPI Capillary Tube 1,100(38.8) Electronic Control Real time dual ON/OFF Timer 7-hour OFF Parts Provided Specifications are subject to change without notice. Induction (4-pole) Induction (6-pole) Mold-proof 1 Mounting plate 2 Remote controller 3 Battery (2 pcs.) 4 Remote controller holder 5 Screw cap (2 pcs.) 6 Drain elbow 7 Vibration proof rubber (4 pcs.) 8 Air clean filter (2 pcs.) (Bamboo Charcoal/Photo-catalytic anti-odor filters) 4

FUNCTIONS REMOTE-CONTROL TRANSMITTER INDOOR UNIT ON/OFF Operation mode selection COOL DRY HEAT AUTOMATIC Air flow selection AUTOMATIC HIGH MEDIUM LOW Negative Ion Room temperature setting 16 C 30 C Timer operation selection CONTINUOUS operation OFF ON Sleep Timer / time setting Operation stops at the set time (OFF timer) Operation starts at the set time (ON timer) 0.5 7.0hours(Sleep timer) Air flow direction control Auto angle selection Auto swing mode Manual mode INDOOR UNIT Sensing the room temperature Room temperature sensor (thermistor) Time delay safety control Restarting is inhibited for approximately 3 minutes. Indoor fan speed control High, Med, Low Operation indication lamps (LED) ELECT (GREEN or RED) Lights up green during operation. Lights up red when negative ions are generated. TIMER (YELLOW) Timer in operation OPERATE (GREEN) Outdoor unit operate Dry operation mode Automatic fan speed control Room temperature control Maintains the room temperature in accordance with the setting temperature. Deice (defrost) control Deicing operation automatically starts when the heating efficiency is declined by the ice formed in the outdoor unit. After deicing operation, heating operation automatically starts with Hot start function. 5

FUNCTIONS OUTDOOR UNIT Hot-start control (heating) The indoor fan stops until the evaporator piping temperature will be reached. Anti-freezing control for the evaporator Compressor will be stopped when the evapolator s piping temperature is below 2 C for one minute. Compressor will be restarted when the evaporator s piping temperature is above 2 C. Airflow direction control Automatic airflow direction control The louver automatically swings up and down (cooling, dry)...horizontal and 35 downward. The louver is set at 70 downward during heating operation. Auto recovery function If there is any power failure during operation, operation status before power failure is memorized. 3 4 minutes after power recovery, the unit restarts automatically with previous operation status memorized. (3 4 minutes is protective time for compressor.) Attention Because of Auto recovery function, if shutting off the power supply during operation, the unit may restart irrespective your intention when turning on the power supply next time. If the unit is not to be used for a long time, shut off the power supply after terminating all operation with remote controller. Inverter control Inverter control reduce the ON/OF times of compressor,so can keep the room temperature changeless during operation. Electricity consumption Inverter control can operate with less electricity consumption than normal air conditioner. 6

EMERGENCY AND TEST OPERATION SERVICE FUNCTION EXPLANATION Emergency Operation Use this operation only when the remote controller is out of order or lost. When the emergency operation switch is pressed, beep starts once, which means the start of this operation. In this operation, the system automatically selects the operation modes, cooling (or heating when available) according to the room temperature, as follows. Beep Temperature Operation mode Designated temperature Timer mode Air flow ABOVE 23 C COOLING 26 C CONTINUOUS AUTOMATIC BELOW 23 C HEATING 23 C CONTINUOUS AUTOMATIC It is not possible to operate in dry mode. Test Operation Test operation switch is same as emergency one. Use this operation only for testing the performance of the machine in the condition where the room temperature is less than 16 C. Continue to press the test operation switch for more than 5 seconds. After you hear twice beep, release your finger from the switch : the cooling operation starts with the air flow speed HI. If the test operation switch is pressed more than 10 seconds, it doesn t work. After 30 minutes, test operation ends automatically. Twice beep HOW TO RELEASE EMERGENCY AND TEST OPERATION In case of releasing during those operations, you can either push emergency operation switch once more or apply operation using remote control. You will hear a beep sound and emergency/ test operation is released. If you release the operation by remote control, operation will continue as setting of the remote control automatically. INTERFERENCE PREVENTION OF SIGNALS FROM THE REMOTE CONTROLLER When two indoor units used in the same room, interference of the signals may happen. To avoid this, alternative signal model B can be selected by the following. (Ex-factory setting is mode A) J1 J1 Remote controller side : Have J1 on the PC board short-circuited by soldering. Indoor unit side : Cut R13 on the PC board. Soldering 7

OPERATION DETAILS TIMER OPERATION ON Timer operation Press the ON/OFF switch. Right after replacing new batteries, set the present time in advance. Set the ON Time : Press the TIME ADJ button twice. Adjust the time with the, button. Press the TIME ADJ button twice.the setting of ON Time is completed and the present time appears on the LCD. Set the ON Timer : Press the Timer fixing button ON. OFF Timer operation Press the ON/OFF switch. Right after replacing new batteries, set the present time in advance. Set the OFF Time : Press the TIME ADJ button 3 times. Adjust the time with the, button. Press the TIME ADJ button once.the setting of OFF Time is completed and the present time appears on the LCD. Set the OFF Timer : Press the Timer fixing button OFF. Sleep Timer operation Press the SLEEP button during the operation. Set the operating period by pressing the SLEEP button until the period designated appears on the LCD. Timer Cancellation ON/OFF Timer : Press the Timer fixing button ON (On Timer) and/or OFF (Off Timer) once again. Sleep Timer : Press the SLEEP button until the operating period on the LCD disappears. AIRFLOW DIRECTION CONTROL Vertical adjustment When ON/OFF switch is pressed, the vertical louver will move to the adequate positions for each operation automatically. Swing of air flow If air flow direction switch is pressed once, the vertical louver will move within the range of figures. Fixing the flow direction If air flow direction switch is pressed again, the vertical louver will be fixed and that position is memorized. From the next operation the louver will be set at previous position automatically. Notes : In Swing Mode, the louver automatically moves up and down within the certain range, as the illustration below. There is two different ranges of louver swinging; one is of cooling & dry mode operation and the other is of heating operation. Standard Position Swing of Air Flow Level Approx.10 degrees (Cooling/Dry) Approx.65 degrees (Heating) Level Approx.10 degrees Cooling Dry Approx.50 degrees Heating Approx.65 degrees 8

OPERATION DETAILS TIME DELAY SAFETY CONTROL FUNCTION - FOR PROTECTION OF COMPRESSOR Compressor will not restart, in any operation modes, for 3 minutes after its stop. Compressor does not stop during the first 6 minutes of its operation even if the room temperature reaches to the designated temperature, except changing setting temperature. COOLING MODE OPERATION The compressor will stop when operational frequency reached the minimum frequency and that condition has been kept for 6 minutes and the room temperature becomes 1 C was set. The compressor will re-start when room temperature becomes 0 C higher than was set. The operational frequency will be set every 1 seconds of operation. The operational frequency setting will be calculated based on the deviation of the room temperature and the set temperature on one end and the deviation factor at the time of previous setting on another. Room temperature Designated temperature 0 C -1 C MAX 2 MAX 2 Frequency of compressor 0 Hz MIN3 MIN3 TAN/ TAG-A28FWIS TAN/ TAG-A32FWIS 1 40 60 2 56Hz 72Hz 3 40Hz 40Hz 9

OPERATION DETAILS DRY MODE OPERATION Compressor stops when the room temperature fall to 0.3 C lower than the designated temperature continuously for 2 minutes. Compressor restarts when room temperature rises to the designated temperature. The operating frequency of the compressor is determined according to the room temperature (see the diagram below). Room temperature Designated temperature 0 C -1 C MAX MAX Frequency of compressor Indoor fan 0 Hz Selected speed Super low MIN OFF (3min.) Super low MIN Selected speed 10

OPERATION DETAILS HEATING MODE OPERATION The compressor will stop when operational frequency reached the minimum frequency and that condition has been kept for 6 minutes and the room temperature becomes 4.7 C was set. The compressor will re-start when room temperature becomes 3.7 C higher than was set. The operational frequency will be set every 1 seconds of operation. The operational frequency setting will be calculated based on the deviation of the room temperature and the set temperature on one end and the deviation factor at the time of previous setting on another. Temperature, indoor heat exchanger 35 C 30 C 15 C Indoor fan Stop Super Low Designate Fan blow Low Low or Super low Designated Fan blow Designated temperature +4.7 Room temperature +3.7 MAX 2 MAX 2 Frequency of compressor 0 Hz MIN3 MIN3 TAN/ TAG-A28FWIS TAN/ TAG-A32FWIS 1 40 60 2 67.3Hz 80.0Hz 3 40.0Hz 40.0Hz 11

OPERATION DETAILS DEFROSTING OPERATION(FOR OUTDOOR UNIT HEAT EXCHANGER) Defrosting operation is controlled by the temperature of outdoor heat exchanger sensed by the thermistor and the timer switch. Defrosting operation starts when the both of the following conditions are met at the same time. a) 40 minutes of continuous run of the compressor after the start of heating operation or after the completion of previous defrosting operation. b) the temperature of the outdoor heat exchanger stays lower than -2 C continuously for two minutes. Defrosting operating is called off if either of the following conditions is met. a) The temperature of outdoor heat exchanger rises to 8 C while 4-way-valve is ON. b) 12 minutes has passed since compressor turned ON. Defrosting starts Defrosting stop Temperature of outdoor heat exchanger 2min. 8 C -2 C 3min. 2min. Compressor Outdoor fan 4way valve 2min. ON OFF 50Hz 67Hz MAX OFF ON ON 10 sec. 50sec. 50sec. ON ON 53sec. Max 12min. 53sec. TAN/ TAG-A28FWIS TAN/ TAG-A32FWIS 60Hz 80Hz 12

TROUBLESHOOTING GUIDE FOR YOUR SAFETY USE TAN : indoor unit TAG : outdoor unit For the safety and proper use and handling of the product, please read and follow the instructions carefully. The meaning of the marks below are as follows. Danger Improper use will cause the significant risk of death or serious injury of the user. Warning Improper use may cause the risk of death or serious injury of the user. Please refer the marks below. Caution High Voltage Off the Plug Prohibited Strict enforcement Connect the earthing cable High Temperatare Danger Be sure to take off the plug when servicing. It may cause the risk of electric shock. If leakage of refrigerant occur in the installation, ventilate a room. If the leaked refrigerant is exposed fire, poisonous gas may be generated. Boosting capacitor make the control box assembly (TAG unit) high voltage. Make the capacitor discharge enough when servicing. Otherwise will be struck by electricity. Check Point Use designated parts or accessories to avoid accidents. In case of gas leakage, not only refill the required amount of the refrigerant gas but also find out the gas leakage point and mend it. If the service work has to be suspended before mending the leakage points, be sure to collect the refrigerant gas in the outdoor unit by using pump then fasten the service ports to avoid any further leakage. Poisonous gas may be generated when the leaked refrigerant is exposed to fire. Clean the pins of the plug and insert the plug completely into the outlet. Be sure to change the cable if it is damaged. Do not use damaged cable. Do not use power supply cord extended or connected in halfway. Warning Check Point Be sure to put the units to earthing works. Be sure to check the insulated resistance, more than 1M Ω. The combinations of three LED indicators (ON/Flashing/OFF) provide the self-diagnosis information as most of them shown in the trouble shooting guide. [Note1] Discharge electricity of the capacitor by making short circuit firstly. Then check the capacitor by tester. Be sure to set up the tester for the measurement of bigger resistance. 13

TROUBLESHOOTING GUIDE INDICATION LAMP Micro computer self-diagnose the points of the troubles and inform it by the combination of the status (On, Flush, or Off) of three lamp indicators on the front panel of the indoor unit. INDICATION LAMP TIMER (yellow) POWER (green) OPERATION (green) ALARM INDICATION TIME APPEARANCE, PORTION, PARTS SEEMED WRONG METHOD OF CHECK (press the ON/OFF button of remote controller in case of reset) OFF OFF OFF POWER SUPPLY REMOTE CONTROL TAN FUSE(3.15A) check the plug inserted into the outlet and the power supply emergency operation (display of remote controller is faint or not) check the electric continuity by tester - - TAN TERMINAL BLOCK check the electric continuity by tester TAN, TAG do not work at all PCB (RECEIVER & DISPLAY) TAN PCB (MAIN) emergency operation other than described above FLASHING OFF OFF SENSOR, TEMP. ROOM check the resistance by tester [see table 1] FLASHING ON ON alarm indication appears short or open of sensor, SENSOR, TEMP. HEAT EXCHANGER check the resistance by tester [see table 2] ON ON immediately when press temperature or incomplete FLASHING operation switch insertion of connector SENSOR, TEMP. DEFROST check the resistance by tester [see table 2] FLASHING ON OFF SENSOR, TEMP. DISCHARGE check the resistance by tester [see table 3] OFF OFF FLASHING MIS-WIRING (TAG-TAN CONNECTING check the wiring connection and rare contact normal lamp indication CABLE) OR RARE CONTACT TAN, TAG don t work at all, error of transmission and after 20 sec., operation turn alarm when CURRENT FUSE. (3A,12A) FUSING check the electric continuity by tester.[see fig. 1] lamp is flashing (2 min. in something is wrong with (ON THE TAG PCB (MAIN)) (if it is no continuity, TAG PCB (main) should be replaced.) case of power on) TAN, TAG FLASHING OFF FLASHING CT disconnection CUTTING OFF CT change the TAG PCB (main) OFF FLASHING OFF 30 40 min. later after compressor start, the yellow lamp is flashing and TAN, TAG stop running sensor discharge operate because temperature of discharge tube beyond 120 C, or sensor discharge is bad quality GAS LEAKAGE VALVE, SERVICE IS CLOSED PIPE SENSOR, TEMP. DISCHARGE check the point of leakage (discharge temperature rise in case of small leakage), measure the pressure of compressor during fixed operation (operation frequency 58 Hz) check the valve by eyes check by eyes check the resistance by tester [see table 3] FLASHING FLASHING OFF FLASHING FLASHING ON FLASHING or OFF ON protective action against excessive AC current once stop running with detection power lamp lighting when something is wrong with TAN, TAG, and start running again after 3 protective action against 20 min. excessive DC current detection later after that in case of or reoccurrence, alarm abnormal revolution of compressor indication appears UNREASONABLE OPERATION UNDER OVERLOAD MOMENTARY STOP OF POWER (IN CASE OF LIGHTNING) DROP OF POWER VOLTAGE UNREASONABLE OPERATION UNDER OVERLOAD MOMENTARY STOP OF POWER (IN CASE OF LIGHTNING) DROP OF POWER VOLTAGE TAG PCB (MAIN) ACCIDENT OF PCB (POWER MODULE) check the place of installation (blockage of air inlet & outlet of TAN, TAG) check the excessive gas check the movement by reoperation check the power voltage (230V) check the place of installation (blockage of air inlet & outlet of TAN, TAG) check the excessive gas check the movement by reoperation check the power voltage (230V) See Flow Chart (P16) COMPRESSOR LOCKING FLASHING FLASHING FLASHING in case of heating operation, after a few minutes operation, all lamps are flashing and TAN, TAG stop running FLASHING ON FLASHING 15 sec. later after main power on, or 60 sec. later after start running through remote controller, alarm indication appears - - - - FILTER IS CHOKED in case of heating operation, a rise of SENSOR, TEMP. HEAT EXCHANGER temperature (above 58 C) of TAN heat exchanger or TAN PCB (MAIN) less quantity of TAG blow FAN MOTOR (TAN) accident of controller not cool down not warm up TAN PCB (MAIN) TAG PCB (MAIN) GAS LEAKAGE SENSOR, TEMP. ROOM SENSOR, TEMP. HEAT EXCHANGER FAN MOTOR (TAN) 4-WAY VALVE SHORT CYCLE (INSUFFICIENT AIR CIRCULATION) check by eyes and clean it check the resistance by tester [see table 2] check the voltage between blue and yellow in connector [see fig.2] if it is not AC 110V 230V, TAN PCB (main) should be replaced other than described above 15 sec. later after main power on, if alarm indication appears, TAN PCB (main) should be replaced 60 sec. later after start running through remote controller, if alarm indication appears, TAG PCB (main) should be replaced check the point of leakage measure the pressure of compressor during fixed operation (operation frequency 58 Hz) check the resistance by tester [see table 1] check the resistance by tester [see table 2] check the voltage between blue and yellow in connector [see fig.2] if it is AC 110V 230V, TAN fan motor should be replaced check the resistance by tester [see fig.3] check the blockage of air inlet & outlet of TAN, TAG - - - - water leakage DRAINAGE MIS-INSTALLATION check the drain hose by eyes (it might be folded or choked) check the TAN whether lean or not - - - - nasty smell FILTER IS CHOKED NO USE FOR A LONG TIME NASTY SMELL (CIGARETTE, FURNITURE, ETC.) check by eyes and clean it use deodorizer - - - - louver doesn' t work LOUVER MOTOR check the resistance by tester [see fig.4] In this table TAN means indoor unit and TAG means outdoor unit. 14

TROUBLESHOOTING GUIDE CHECK A FOLLOWING STEPS fig. 1Continuity of current fuse on the TAG PCB (main) Take off the connector 2 on the TAG PCB (main), and check the continuity. fig. 2Voltage of TAN fan motor on the TAN PCB (main) fig. 3Resistance of 4-way valve coil blue red yellow TAN fan motor connector tester attention electric shock Normal:110V 230V 4-way valve coil 1.5k Normal:1.5kΩ voltage Check the TAN PCB(main) Measure the voltage between the connector pins in the back of TAN PCB(main) Take off the connector and check the Resistance of 4-way valve coil fig. 4Resistance of louver motor fig. 5PCB(Power module) (5) (1) common terminal tester resistance terminal block PCB(Power module) Normal:360 390Ω Take off the connector and check the resistance between the common terminal and each terminal fig. 6Voltage of PCB(Power module) Take off the connectors 1 9 in PCB(Power module) Measure the resistance, between U-V, V-W, W-U, V-U, W-V, U-W, respectively. If all the figures show infinite (more than hundreds of kω) and similar one another( 30%) then the module is normal condition. if not, it is defective. fig. 7Resistance of TAG PCB(main) (3) Measure both voltages as follows without taking off the connectors. between (3) in the 24 and 8 approx. DC 5V 1V between (8) in the 23 and 8 approx. DC 15V 2V (1) (8) (1) TAG PCB(main) Both PCB (Power module) and TAG PCB(main) are normal (3) (1) (8) TAG PCB(main) (1) Measure both resistances as follows after taking off the connectors. between (3) in the 24 and 8 approx. TAG PCB(main) is normal. over 1kΩ between (8) in the 23 and 8 approx. over 1kΩ 15

TROUBLESHOOTING GUIDE METHOD OF CHECK DC excessive current detection and in case of irregular work of compressor Flow Chart check the damage of piping, excess gas check the resistance of PCB(Power module) [see fig.5] normal YES NO accident of PCB(Power module) check the voltage (230V) between 1 and 2 in terminal of TAG normal YES NO check the power supply wiring check the voltage of TAG PCB(main) [see fig.6] normal YES NO take off the connectors 23 & 24 accident of compressor the resistance of TAG PCB(main) [see fig.7] normal YES NO accident of TAG PCB(main) accident of PCB(Power module) 16

TROUBLESHOOTING GUIDE ELECTRIC CHARACTER table 1Sensor, temp. room table 2Sensor, temp. defrost Sensor, temp. heat exchanger table 3Sensor, temp. discharge Temp.( C) Resistance (kω) Temp.( C) Resistance (kω) Temp.( C) Resistance (kω) 10 47 0 31 10 1,000 15 37 5 24 20 600 20 29 10 19 35 300 25 23 15 15 40 250 30 18 20 12 50 160 35 15 25 10 80 50 30 8 35 7 DISPLAY OF ERRORS IN THE PAST Push emergency operation switch and hold for more than 10 seconds while unit is not operated and release the switch when you hear three beeps. You will see the latest error by indication lamp. Further pushing of the switch will make the error indication by reversing cycle up to four latest errors in the past. At any stage, the error indication will disappear after 30 seconds. Hold switch for more than 10 seconds Another push Another push Another push Another push Three beeps Two beeps Three beeps Four beeps One beeps The latest error indication The second latest error indication The third latest error indication The fourth error indication Indication lamp goes off 17

TROUBLESHOOTING GUIDE WIRING DIAGRAM TAN-A28FWIS TAN-A32FWIS TAG-A28FWIS TAG-A32FWIS 18

PERFORMANCE CURVE DIAGRAM REMARKS FOR GAS PRESSURE CHECK AND CHARGING Gas pressure is to be measured at COMPULSORY COOLING OPERATION for cooling or EMERGENCY OPERATION for heating. (It is operated for 30 minutes at 58Hz fixed frequency.) If you find substantial diffrence in performance compared with PERFORMANCE CURVE as shown next, recharge the refrigerant. (In order to avoid excessive charging, purge all the remaining refrigerant first and then evacuate the unit completely with vacuum pump and finally apply rated volume charging of refrigerant.) Charging of refrigerant should be done by cooling operation, because the pressure at service valve will be too high at heating cycle, then the heating performance characteristics must be checked by restarting of heating operation. Piping size Liquid side Gas side 6.35mm 9.52mm Max. tube length Max. height difference 15m 10m 19

PERFORMANCE CURVE DIAGRAM TAN/TAG-A28FWIS COOLING (A) 5.0 4.5 CURRENT 4.0 3.5 3.0 2.5 2.0 ( C) 30 25 TEMPERATURE BLOW OUT 20 15 (MPa) 1.5 SERVICE PORT PRESSURE 10 5 0 1.3 1.1 0.9 0.7 0.5 20 25 30 35 ( C) HUMIDITY60% AIR TEMPERATURE INDOOR-OUTDOOR HEATING (A) 5.0 AIR-TEMPERATURE INDOOR 20 C CURRENT 4.5 4.0 3.5 3.0 ( C) 45 TEMPERATURE BLOW OUT 40 35 (MPa) 1.5 SERVICE PORT PRESSURE 1.0 0.5 0.0 5 10 15 20 ( C) HUMIDITY50% AIR TEMPERATURE-OUTDOOR 20

PERFORMANCE CURVE DIAGRAM TAN/TAG-A32FWIS COOLING (A) 5.0 4.5 CURRENT 4.0 3.5 3.0 2.5 2.0 ( C) 30 25 TEMPERATURE BLOW OUT 20 15 (MPa) 1.5 SERVICE PORT PRESSURE 10 5 0 1.3 1.1 0.9 0.7 0.5 20 25 30 35 ( C) HUMIDITY60% AIR TEMPERATURE INDOOR-OUTDOOR HEATING (A) 5.0 AIR-TEMPERATURE INDOOR 20 C CURRENT 4.5 4.0 3.5 3.0 ( C) 45 TEMPERATURE BLOW OUT 40 35 30 (MPa) 1.5 SERVICE PORT PRESSURE 1.0 0.5 0.0 5 10 15 20 ( C) HUMIDITY50% AIR TEMPERATURE-OUTDOOR 21

TAN-A28FWIS, TAN-A32FWIS ELECTRIC CIRCUIT DIAGRAM INDOOR FAN MOTOR BLACK WHITE RED TERMINAL BLOCK GREEN/ YELLOW TERMINAL BLOCK 1 2 3 (TO OUTDOOR UNIT) 1 3 5 CN7 RL2A C1 RL1TAB1 BLACK WHITE RED CN2 RL1TAB2 D1 CN4 C3 L1 PC2B C2 CF1 ZE1 250V T3.15A RL1A PC1B PC3A R2 (INDOOR UNIT) CN1 THERMISTOR (EVA) THERMISTOR (ROOM) 1 2 3 1 2 3 4 CN9 CN11 PCB(MAIN CONTROLLER) CN8 1 2 3 4 5 6 1 3 CN6 1 3 CN12 LOUVER MOTOR P S TRANSFORMER R21 D2 C11 IONIZER AC CORD 1 2 3 YELLOW RED BLUE 1 3 1 2 BLACK WHITE BROWN R3 PC1A PC2A RL1B RL2B 7 PCB(RECEIVER & DISPLAY) 1 2 3 4 5 6 7 CN1 IONIZER LED ELECT LED TIMER LED OPERATE LED RECEIVER UNIT IC1 PC3B 1 2 3 4 5 RED BLUE MANUAL SW RED BLUE WIRELESS REMOTE CONTROL 22

TAG-A28FWIS, TAG-A32FWIS ELECTRIC CIRCUIT DIAGRAM 23

EXPLODED VIEW (INDOOR UNIT) TAN-A28FWIS TAN-A32FWIS 22 25 26 27 31 28 29 15 23 14 11 24 9 20 13 4 7 1 5 6 2 27 12 3 8 21 21 16 30 19 10 18 17 24

EXPLODED VIEW (OUTDOOR UNIT) TAG-A28FWIS 2 6 7 17 5 10 4 13 23 21 22 1 20 28 26 25 9 14 18 19 24 8 15 16 12 16 16 11 27 4 3 25

EXPLODED VIEW (OUTDOOR UNIT) TAG-A32FWIS 2 6 7 17 5 10 4 13 23 21 22 26 1 20 28 25 9 14 18 19 24 8 15 16 12 16 16 11 27 4 3 26

PARTS LIST (INDOOR UNIT) NO. PARTS NAME TAN-A28FWIS TAN-A32FWIS 1 CONTROLLER ASSY. 20422620 20422630 2 PCB (MAIN) 30055500 30055550 3 PCB (RECEIVER & DISPLAY) 30055510 4 5 SENSOR (TEMP,ROOM & HEAT EXCHAGER) 30013610 30055070 30054290 30021680 6 TRANSFORMER 51955370 30055520 7 TERMINAL BLOCK 51620840 8 CORD,POWER SUPPLY 30021550 9 FRONT PANEL ASSY. 20088200 10 INLET GRILLE 20031020 11 REAR CASE ASSY. RC00300-20003 12 WIRING LID 20044490 13 MOTOR,FAN 14 TANGENTIAL FAN L2-12300 L2-02200 K1-02800 K1-00200 K1-02500 15 BEARING ASSY. RC00100-42000 16 DRAIN PAN ASSY. 20412630 51621270 51621030 17 MOTOR,LOUVER 51621010 30027370 51621040 18 LOUVER (UP-DOWN) 20044450 19 DRAIN HOSE 51620000 20 EVAPORATOR ASSY. 20422600 21 AIR FILTER 20205120 22 MOUNTING PLATE ASSY. RC00100-21003 23 PIPING SUPPORT (1) RC2021-516 24 MOTOR SUPPORT RC2521SV-51800 25 REMOTE CONTROLLER ASSY. 20431840 26 REMOTE CONTROLLER HOLDER 20139550 27 SCREW CAP 20048420 28 BATTERY 30057750 29 DRAIN ELBOW 20148080 30 IONIZER 30055490 31 AIR CLEAN FILTER 30060970 27

PARTS LIST (OUTDOOR UNIT) NO. PARTS NAME TAG-A28FWIS TAG-A32FWIS 1 FRONT PANEL ASSY. 20050670 2 SIDE PANEL ASSY. 20046550 3 BOTTOM PANEL ASSY. 20412770 4 VALVE COVER 20050690 5 PROPELLER FAN 52630380 52630180 6 MOTOR 53501650 53501540 7 BRACKET, MOTOR 20038120 20219780 8 COMPRESSOR 30055600 9 TERMINAL BLOCK 51620820 10 CONDENSER ASSY. 20422250 20422260 11 VALVE,SERVICE (3/8) 51535700 12 VALVE,SERVICE (1/4) 51535330 13 BAFFLE PANEL ASSY. 20421860 14 SOUND PROOF MATERIAL1 20425870 15 SOUND PROOF MATERIAL2 20425880 16 VIBRATION PROOF RUBBER (comp.) 30057790 17 FIXTURE,CORD 20038190 18 4-WAY VALVE ASSY. 20422290-19 COIL,4-WAY VALVE 51202320 20 SOUND PROOF MATERIAL3 20425890 21 REACTOR 30055560 22 CONTROLLER ASSY. 20412790 20412800 51100960 23 SENSOR (TEMP.DEFROST) 51100600 30054280 51100870 24 SENSOR (TEMP.DISCHARGE) 51101350 30054310 25 PCB (MAIN) 30055570 30055580 26 PCB (POWER MODULE) 30055590 27 VIBRATION PROOF RUBBER (UNIT) 20046680 28 SOUND PROOF MATERIAL4 20428920 28

RA-37-[1] ISSUED MAR.2005 Printed in Japan