MODEL AV2-C1D1M Hazardous Duty Class I. Div 1, Multitone Alarm Station

Similar documents
DETCON MODEL AV1/AV2-C1D2M Hazardous Duty Class I. Div 2, Multitone Alarm Station

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station

DETCON MODEL SW-AV2-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

DETCON MODEL SW-AV1-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

Model 100 Duct Mount Kit

Vibratone Horns. Models 350 and 450

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

C1D1 Explosion Proof Horn - Industrial Siren - Programmable Timer - NEMA 4X - Weatherproof

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

The Signal Is Clear TM

Installation and Maintenance Manual. Model 154XST Series Strobe Light for Use in Hazardous Conditions. français...page 21 español...

TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

GAS MONITOR Model Model

120W Explosion Proof Signal Light w/ Audible Alarm - C1D1 - (2) Colored LED Lamps - 55 Horn Tones

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

INSTRUCTION & SERVICE MANUAL

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

Class 1 Division 2 Hazardous Location Stack Light - Signal Traffic Light - Multiple Lamp Colors

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Alarm Tone Generator Model AG17

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Explosion Proof Line Powered Telephone Ringer

INSTRUCTION & SERVICE MANUAL

Street Thunder ST240 SIREN AMPLIFIER INSTALLATION AND OPERATING INSTRUCTIONS

DC Microstrobes AC Microstrobes

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Installation and Operation Manual. Wireless Indoor Strobe

Static Pressure Alarm For Hazardous Location Fume Hoods

Hazardous Location Supervised Warning Light

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

TOLL FREE PHONE FAX

INSTALLATION AND INSTRUCTION MANUAL

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

About Tomar Audible Alarms 1000 & 1100 Power Alarm WEP Explosion Proof Power Alarm Siren

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

Model 9001, Alarm

MODELS 304GC, 304GCX, 314GC, and 314GCX

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

Global Water Instrumentation, Inc.

THUNDER LOW FREQUENCY AMPLIFIER INSTALLATION MANUAL

Pilot devices Stacklights Signal beacons

TrueAlert Multi-Candela Notification Appliances

TOLL FREE PHONE FAX

SELECT-A-HORN/STROBE SERIES

Certificate of Compliance

TrueAlert Addressable Notification Appliances

Feniex Hammer S Distributed By: Feniex Hammer Instruction Manual / feniex.com

380 SERIES REMOTE SIREN ETSA380R

INSTRUCTION MANUAL C-4010 SCAN HERE

Certificate of Compliance

Instruction Manual Model L2 RF Switch

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

SIMPLEX WEATHERPROOF CONTROL PANELS

385 SERIES REMOTE HANDHELD SIREN ETSA385HR

Colibri. Automatic Tank Gauge CL6 Series Installation Guide

Alnor AirGard 410HE Air Flow Monitor for Hazardous Environment Fume Hoods

INSTALLATION INSTRUCTIONS

Model 9001, Alarm

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

SEC 2000 Millenium Infrared Gas Detector

PRM-100 INSTALLATION MANUAL OUTDOOR PARAPET ROOF MOUNT WITH ELL CONDUIT BOX MANUAL NUMBER

Certificate of Compliance

MODELS ASHP, ASHH, ASUP, and ASUH

TrueAlert Multi-Candela Notification Appliances

Detcon MicroSafe Model DM-634C Oxygen Deficiency Sensor (0-25% O2)

OPERATING AND INSTALLATION

SA VOLT SIREN AMPLIFIER

Brasch Hazardous Location Unit Heaters

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

TrueAlert Addressable Notification Appliances

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

SA SIREN AMPLIFIER WITH MECHANICAL TONE

STATUS ALARM HISTORY ALARM RESET

Carson Manufacturing Co., Inc North Rural Street Indianapolis, IN Phone: (888) Fax: (317)

DWA2000. WAAS Annunciator. Installation and Operations Manual. Rev 1.0 August 2014

Series M22 Signaling Beacons and Alarms

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Hazardous Area Telephone Model EP600

Informer100 Speaker Models I-IP100AC and I-IP100DC

STORM PRO Model # - C-4014, C Storm Pro- Instruction Manual V.2. This instruction manual serves as a guide for the Storm Pro.

Model 4001 Series Single Channel Controller

TrueAlert Notification Appliances

Smart Series TAS-05-11, TAS-05-12

Process Protection. MFA 4P Motion Failure Alarm

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

DWA2000. WAAS Annunciator. Installation and Operations Manual. Rev 1.1 December 2014

SA SIREN AMPLIFIER

Eclipse 8 & Eclipse NH

Mounting Kits. LWMB2 6" 6 3 /8" 5 7 /8" 2.6 lbs lbs. LCMB2 6" 5" 5 3 /4 2.3 lbs. 2.5 lbs.

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information

Transcription:

MODEL AV2-C1D1M Hazardous Duty Class I. Div 1, Multitone Alarm Station Operator s Installation and Instruction Manual DETCON, Inc. 3200 Research Forest Dr., The Woodlands, Texas 77387 Ph.281.367.4100 / Fax 281.298.2868 www.detcon.com August 20, 2007 Document #3327 Revision 1.3

This page left intentionally blank AV2-C1D1M Instruction Manual Rev. 1.3 ii

Table of Contents 1.0 Description... 1 1.1 Strobe... 1 1.2 Siren... 2 2.0 Installation... 3 3.0 Spare Parts List... 6 4.0 Warranty... 6 Table of Figures Figure 1 Strobe... 1 Figure 2 SSTX-MV Siren... 2 Figure 3 SSTX-MV printed circuit board... 3 Figure 4 120/240VAC Wiring diagram... 4 Figure 5 24VDC Wiring Diagram... 5 AV2-C1D1M Instruction Manual Rev. 1.3 iii

This page left intentionally blank Shipping Address: 3200 A-1 Research Forest Dr., The Woodlands Texas 77381 Mailing Address: P.O. Box 8067, The Woodlands Texas 77387-8067 Phone: 888.367.4286, 281.367.4100 Fax: 281.292.2860 www.detcon.com sales@detcon.com AV2-C1D1M Instruction Manual Rev. 1.3 iv

1.0 Description AV2-C1D1M Detcon Model AV2-C1D1M audio-visual alarm stations are designed for installation and use in hazardous duty, corrosive work environments. The strobes are UL listed for Class I, Division 2, Groups C and D; Class II, Groups E, F, and G; and Class III. The siren is UL listed for Class I, Groups B, C and D; Class II, Groups E, F, and G. The alarm station consists of two strobe lights and a siren. The station can be wired to control circuit alarm devices for the purpose of warning personnel of hazardous conditions. When used in conjunction with Detcon controllers, the alarm station is typically used to provide a low alarm (strobe) and high alarm (strobe/siren) for pre-determined hazardous environmental gas levels (toxic or flammable) as indicated by remotely mounted sensors. The alarm station strobe lights may be configured with any combination of strobe colors such as amber, blue, clear, green, or red. Dome guards are included. The rugged strobe lights are specifically designed for hazardous locations or corrosive environments where a very bright visual signal is required. 1.1 Strobe Figure 1 Strobe Hazardous location strobe lights are available in voltage ratings of 24VDC, 120 VAC or 240 VAC. The strobe light provides 85 high-intensity flashes per minute. The dome guard fits over the glass dome to protect it against accidental collision with moving equipment. Specifications Strobe Voltage 24VDC, 120 VAC 50/60 HZ, 240 VAC 50/60 HZ Mount Flange Operating Current 0.63Amps at 24 VDC, 0.17 Amps at 120VAC, 0.075 Amps at 240 VAC Strobe Colors Amber/Blue/Clear/Green/Red AV2-C1D1M Instruction Manual Rev. 1.3 Page 1 of 6

Dome Guard Included Operating Temperature Minimum -40 C Operating Temperature Maximum 55 C Flash Rate/Minute 85 Effective Candle Power 200 Enclosure Rating Type 4X, IP 66 Height 13.69 in. Diameter 7.44 in. AV2-C1D1M 1.2 Siren Figure 2 SSTX-MV Siren The explosion proof power alarm siren is available in voltage ratings of 24VDC, 120VAC or 240VAC @ 50/60Hz. and mounts on an omni directional mounting bracket with conduit access Specifications Voltage Mount Operating Current Temperature Rating Sound Output db (A) @ 10 on Axis Wail 108 Yelp 108 Horn 102 Temporal Slow Whoop 102 Enclosure Rating 24VDC, 120 VAC 50/60 HZ, 240 VAC 50/60 HZ Omni Directional Mounting Bracket 0.6Amps at 24 VDC 0.21Amps at120 VAC 0.12Amps at 240 VAC -35 C to +72 C;-31 F to +161 F Type3R, IP44 Height 14.75in. Width 8.88in. Long 14.75in Sound Selectable Positions Listed on Figure 3 AV2-C1D1M Instruction Manual Rev. 1.3 Page 2 of 6

Figure 3 SSTX-MV printed circuit board 2.0 Installation The assembly is a T-shaped aluminum bracket with holes pre-drilled to accommodate (2) U-bolt attachments up to 3 maximum diameter pipe. Overall dimensions are 39 H x 30 W x 18.5 D. The tone for the siren is set using tone selector jumpers, J4 & J5. Each jumper consists of three pins and the selection of appropriate tone is made by placing a jumper on two of the three pins as shown in Figure 3. The alarm comes pre-wired for the appropriate voltage as ordered from the factory. Customer wiring is installed through opening at bottom of lower junction box. Connect wiring in accordance with the wiring diagrams in Figure 4 or Figure 5. Use only 12 to 18 AWG wire for power connections. Strip no more than 0.25-inch of insulation from the ends of the power leads. AV2-C1D1M Instruction Manual Rev. 1.3 Page 3 of 6

STROBE 1 SIREN STROBE 2 L1 N G L1 N G L1 N G BLACK RED BLUE WHITE GREEN GREEN L1 Strobe 1 L1 Siren L1 Strobe 2 Neu (L2) GND Customer Input Wiring Figure 4 120/240VAC Wiring diagram AV2-C1D1M Instruction Manual Rev. 1.3 Page 4 of 6

STROBE 1 SIREN STROBE 2 + - G + - G + - G VDC+ Strobe 1 VDC+ Siren VDC COMMON RED GND RED VDC+ Strobe 2 RED BLACK GREEN Customer Input Wiring Figure 5 24VDC Wiring Diagram AV2-C1D1M Instruction Manual Rev. 1.3 Page 5 of 6

3.0 Spare Parts List AV2-C1D1M Detcon Part # Description 300-679612-ABS 356-889321-MV0 354-3156X4-124 354-3200X4-120 354-3300X4-240 Sub Assembly Replacement Parts OEM Part # Description Six Pin ABS Terminal Block 24 VDC / 120 VAC / 24 VAC Hazardous Location Siren 3150 BEP-FM-Color/BEPG Strobe 12-74VDC (X represents color of lamp) 3200 BEP-FM-Color/BEPG Strobe 120 VAC (X represents color of lamp) 3300 BEP-FM-Color/BEPG Strobe 240 VAC (X represents color of lamp) Strobe colors: Red (2), Amber (4), Green (5), Blue (6), and Clear (9) SA1044 SA1045 SA1046 M0182B FP0017-X K2001177C K140340B 3200 BEP-PSA 120 VAC 50/60 Hz Strobe power supply assembly 3300 BEP-PSA 240 VAC 50/60 Hz Strobe power supply assembly 3150 BEP-PSA 12-74 VDC Strobe power supply assembly Guard BEPG for BEP Strobe 700-R1- (Color) Hermetically sealed lo-profile head (X represents color of lamp) SSTX-MV PC Board Assembly 4-Position Connector 4.0 Warranty Detcon Inc., as manufacturer, warrants under intended normal use each new Model AV2-C1D1M Alarm Station to be free from defects in material and workmanship for a period of one year. The warranty period begins from the date of shipment to the original purchaser and ends one year thereafter. All warranties and service policies are FOB the Detcon Inc. facility located in The Woodlands, Texas. Shipping Address: 3200 A-1 Research Forest Dr., The Woodlands Texas 77381 Mailing Address: P.O. Box 8067, The Woodlands Texas 77387-8067 Phone: 888.367.4286, 281.367.4100 Fax: 281.292.2860 www.detcon.com sales@detcon.com AV2-C1D1M Instruction Manual Rev. 1.3 Page 6 of 6