Guidelines for sizing roof windows

Similar documents
Windows Influence on Room Daylighting in Residential Buildings

Effectiveness of sprinklers in residential premises:

A Review of Hydronic Balancing of Cooling Water Circuit

Library of Birmingham integrated with The REP

DAYLIGHTING ANALYSIS. Generic Design/Analysis Methods (applicable to all sorts of systems)

Residential Cluster, Ahmedabad: Housing based on the traditional Pols

13-15, 2001 USING LIGHTING SIMULATION TO ASSESS THE PERFORMANCE OF AND INDIRECT OFFICE LIGHTING SYSTEMS IN DYNAMIC WORKPLACES

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

Knowledge Based Expert System Computer Aided Climate Responsive Integrated Approach to Architectural Design

1.1. SCOPE OF THE WORK:

Buidling 661 Annual Daylight Performance Modeling Studies

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

DAYLIGHTING PERFORMANCE ON VENETIAN BLIND FOR HEALTHY APARTMENT HOUSING

EFFECT OF COMPACTION ON THE UNSATURATED SHEAR STRENGTH OF A COMPACTED TILL

Compression of Fins pipe and simple Heat pipe Using CFD

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings

Daylight and Whole-Building Energy Analysis Using Radiance in IES <Virtual Environment>

When Precision is not good enough

Evaluation on Residential Energy Efficiency Programs Using the City-Scale End-Use Simulation Model

Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products

On the Architectural Engineering Competences in Architectural Design MSc in Engineering with Specialization in Architecture Kirkegaard, Poul Henning

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Furniture Industry Research Association Project 60th Anniversary Report Design and Innovation Competition in conjunction with Blum UK

Functional Safety: the Next Edition of IEC 61511

FLIGHT UNLOADING IN ROTARY SUGAR DRYERS. P.F. BRITTON, P.A. SCHNEIDER and M.E. SHEEHAN. James Cook University

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

3(iv)(b) TCP/11/16(29)

Prescription of qualifications. ARB Criteria at Part 2

Recent BRANZFIRE enhancements and validation

Reducing the Carbon Footprint of Existing Domestic Heating: A Non-Disruptive Approach

PRELIMINARY ANALYSIS OF THE NUMBER OF OCCUPANTS, FIRE GROWTH, DETECTION TIMES AND PRE-MOVEMENT TIMES FOR PROBABILISTIC RISK ASSESSMENT

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

Shortcut Model for Predicting Refrigeration Cycle Performance

Copyright 2017 Integrated Environmental Solutions Limited. All rights reserved.

OEIRAS MASTERPLAN: A METHODOLOGY TO APPROACH URBAN

PLANNING COMMITTEE. 14 October 2014

Daikin VRV Systems Plugin VE2012 User Guide

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

CERBERUS: A NEW MODEL TO ESTIMATE SIZE AND SPREAD FOR FIRES IN TUNNELS WITH LONGITUDINAL VENTILATION

Air Conditioning for Industrial and Commercial Buildings

Developing Early Design Simulation Tools For Persons with Vision Impairments

Computer Modelling and Simulation of a Smart Water Heater

THREE DIMENSIONAL SLOPE STABILITY

GAS DETECTOR LOCATION. Ø.Strøm and J.R. Bakke, GexCon AS, Norway

Drying principles and general considerations

Victoria & Albert Museum, London Medieval & Renaissance Galleries: A Passive Approach to Humidity Control

NUMERICAL SIMULATION OF FIRE SPREAD IN TERMINAL 2 OF BELGRADE AIRPORT. PO Box 522, Belgrade, Serbia and Montenegro

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

Slope stability assessment

Aalborg Universitet. Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li

Conventional Electric Space Heating Systems

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

Daikin VRV Sizing & Simulation Plug-in User Guide

Clare Hall daylight in window design

Controlled Door Closing Devices

CHAM Case Study Numerical Simulation of a Air-to-air Cross-flow Heat Exchanger

Press Release. How can the efficiency of the dryer section be increased? Dryer Section All Paper Grades. Heimbach wherever paper is made.

Measurement of Attic Temperatures and Cooling Energy Use in Vented and Sealed Attics in Las Vegas, Nevada

FIRE RESISTANCE LEVEL ASSESSMENTS AND DEVELOPMENT OF APPROPRIATE INPUT DATA

English Version. Daylight of buildings

A Simulation Study on the Energy Efficiency of Gas-Burned Boilers in Heating Systems

NRG SYSTEMS, HINESBURG, VT

Electric radiator test

Daylight at home: differences between developers and architectural competition houses

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

POSSIBILITY TO USE SOLAR INDUCED VENTILATION STRATEGIES IN TROPICAL CONDITIONS BY COMPUTATIONAL FLUID DYNAMIC SIMULATION

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

Mango Sheet Drying by the Solar Dryer Combine with Electric Coil

Thick-Film Heater achieves Superior Performance in Thermal Response, Uniformity and Efficiency.

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

Exercise 2-4. Heat Exchangers (Optional Exercise) EXERCISE OBJECTIVE DISCUSSION OUTLINE. Description of a brazed plate heat exchanger DISCUSSION

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

3D-Evaluation Method for Descaling Capability of Hot Strip Mill

Information Bulletin

Effect of Interaction of Object Color and Lighting Color on a Person s Impression of Interiors

Case studies of Color Planning for Urban Renewal

NUMERICAL SIMULATION OF THE NEW SOUTH WALES FIRE BRIGADE COMPARTMENT FIRE BEHAVIOUR TRAINING TEST CELL

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

MODULATING CONTROL OF LOW NO X BURNERS

Performance of Geosynthetics in the Filtration of High Water Content Waste Material

Development Of A Low-Cost Heat Pump Water Heater For Residential Applications

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Fire Performance of external thermal insulation for walls of multistorey buildings

Smart Green Roofs: Cooling with variable insulation

Stability of Inclined Strip Anchors in Purely Cohesive Soil

Distribution systems in apartment buildings

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

A DETAILED ANALYSIS OF SLOPE STABILITY USING FINITE ELEMENT METHOD (FEM)

Case Study of an Innovative HVAC System with Integral Dehumidifier. Florida Solar Energy Center Cocoa, Florida

1. COOL ROOFS. What is a Cool Roof

CFD Model of a Specific Fire Scenario

A Regional Research and Dissemination Programme. Phase III SOLAR BOX DRYER DESIGN, CONSTRUCTION AND OPERATION MANUAL

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Crop Management Details Start from Parameters settings Emergence Planting Seed brand: Settings Parameter settings Hybrid-specific Generic

Transcription:

Eco-Architecture: Harmonisation between Architecture and Nature 351 Guidelines for sizing roof windows S. Robertson & M. Thompson University of East London and the Centre for Alternative Technology, UK Abstract Roof windows are often used as a major glazing element in loft conversion projects and to create a room in the roof space of new residential developments. Selecting the correct size of roof window is subject to a range of potentially competing influences, including the need to satisfy building regulations and planning control legislation. This paper describes a recent investigative project to address a particular research question: When considering the daylighting and energy consumption aspects, how can designers determine the appropriate size and position for roof windows in loft rooms? The primary objective was to identify appropriate roof window size and position for a typical loft room, when based on accepted numerical daylighting criteria. The research method that was adopted used standard calculations, scale modelling under an artificial sky, computer simulations and internal illuminance measurements for real loft rooms. The relative daylighting performance of a dormer window was also determined using similar techniques. By considering an example of typical modern residential construction, it was then possible to illustrate the effect of variation in roof window size on annual energy consumption. Finally, the paper outlines the preliminary development of a simple graphical design tool that exploits the research. This tool is intended to assist homeowners and designers in selecting roof windows that optimise both the daylighting and energy consumption aspects. Keywords: roof windows, dormer windows, loft conversions, daylighting, energy consumption, design tools. 1 Introduction Roof windows are tilting double glazed units that are fitted in the plane of the sloping roof surface. Such windows are often used as a major glazing element in conversion projects for domestic lofts, agricultural barns and former industrial doi:10.2495/arc060351

352 Eco-Architecture: Harmonisation between Architecture and Nature buildings. Modern construction techniques including structural insulated roof panels and planning trends such as the higher density requirements for new residential developments mean that roof windows are also increasingly used to illuminate rooms within the roof space of new build housing. Selecting the appropriate size for roof windows is subject to a range of potentially competing influences, including the need to satisfy building regulations and planning control legislation. For instance, the understandable desire for a well daylit interior with consequently low electric lighting load may well conflict with the need to achieve a low average U value and the associated reduction in the annual heating energy requirement. In relation to the sizing and position of conventional vertical windows, the question of daylighting has been investigated and documented by authors such as Hopkinson et al. [1] and Littlefair [2]. Much of this work on daylighting theory has been embodied in practical guides including the CIBSE Lighting Guide LG10 Daylighting and Window Design [3]. Baker and Steemers [4] have produced material that describes the potential conflict between daylighting and thermal performance requirements and have developed this to provide predictive techniques such as the LT Method. However, there is little independently published work to provide the same degree of guidance for sizing roof windows. Whilst it is possible to determine optimum roof window size using some of the sophisticated lighting and thermal simulation tools that are now available to designers, this level of effort is unlikely to be appropriate for a typical loft conversion or new build project. Consequently, for mainstream construction projects it is common practice to refer to the available industry guidance from industry bodies and manufacturers in order to identify design solutions. As far as the leading manufacturer of such windows is concerned, the available guidance on the topic of roof window sizing has historically used a comparatively simple rule of thumb approach [5]. This proposes a minimum glazed area equivalent to 10% of the floor area in order to achieve adequate natural daylighting levels. It is further suggested that the overall effect is usually improved by increasing this ratio to around 20% of the floor area. An associated common statement is that a roof window will admit 40% more light than the equivalent dormer window. This guidance also appears in a number of texts that are aimed at homeowners who may be considering a loft conversion project [6]. Choosing the correct size of roof window is important both for external aesthetic and building performance reasons. Although normally prevented by compliance with Building Regulations limits, extreme instances of incorrect sizing could actually produce loft rooms that are unusable. This might be due either to the creation of a poorly illuminated, stuffy attic or a loft room with such a large area of glazing that it resembles a solar oven in summer and a cold garret in the winter. Selecting the optimum size of roof window can undoubtedly produce light, airy loft rooms so the objective of the research was to increase the frequency of this situation for future design projects. Estimates of the total number of such roof windows that are being installed each year were derived from sources such as manufacturer revenue data [7] and the English House

Eco-Architecture: Harmonisation between Architecture and Nature 353 Condition Survey [8]. It appears that there are approximately 450,000 roof windows being installed in the UK each year, so any general trend towards inappropriate sizing can reasonably be multiplied by this value to determine the cumulative effect. Therefore the aim of the research was to answer the question: When considering the daylighting and energy consumption aspects, how can designers determine the appropriate size and position for roof windows in loft rooms? 2 Objectives The primary objective was to identify appropriate roof window size and position for a typical loft room, when based on accepted numerical daylighting criteria. Average daylight factor (ADF) is defined as the ratio of average indoor to outdoor illuminance and is the most commonly used indicator of daylighting within a nominated room. The current British Standard BS8206 [9] specifies required daylighting levels based on ADF values of between 1% and 2.5% subject to the intended use of the room in question. However, it is generally accepted that most people now prefer daylighting levels that are approximately twice those defined in this standard [10]. Therefore, this study considered daylighting levels in the range 2% to 5%, with an optimum value of 3.5% at the centre of this ideal range. The particular case of a loft room was selected since it represents one of the most frequent situations in which such windows are used. It also provided a common test case to which a number of different assessment techniques could be applied. The loft room dimensions that were used were consistent with those published in the guidance notes from the leading manufacturer of roof windows [11]. A physical 1:10 scale room was constructed for comparative investigation and a standard CAD toolset was used to create a software representation of the same loft room. In addition, these dimensions matched those of an available full size loft room. It was therefore possible to use a number of different research tactics to determine these indicators and compare them with real world data. Numerical results and observations associated with these different approaches are considered in the following section. 3 Research 3.1 Calculation A proposed calculation method for ADF is described by Littlefair [2] and cited in LG10 [3]. This is a widely accepted single stage technique that is used to calculate ADF from a number of fixed variables. Although this approach is more usually applied to vertical windows, LG10 does show it being applied to sloping glazing and in the absence of any other readily available single stage technique, this method has been used to assess its suitability for sizing roof windows during the loft room design process. This is found using the Littlefair and Plymouth expression:

354 Eco-Architecture: Harmonisation between Architecture and Nature ADF = TA w /A(1-R 2 )% where the terms have the following meanings: T A w A R diffuse transmittance of the glazing net area of the window angle of the visible sky in degrees total area of the room surfaces average internal surface reflectance Based on these calculations, it seems that the predicted ADF for the typical loft room will be approximately x0.35 the ratio of glazing to floor area. This implies that a roof window of 10% of the floor area would result in an ADF of 3.5%, which is in the centre of the ideal range. 3.2 Scale modelling Next, a scale room placed under an artificial sky was used to determine the ADF for a number of test cases. The 1:10 scale room had dimensions equivalent to 4.0m x 2.5m internal floor plan and 2.5m internal ceiling height with a 45 o pitch. The internal finishes of the scale room were generally identical with those of the full size room and the external surfaces of the scale room were finished in black to represent a typical concrete tile or slate roof surface. As is normal practice for such scale rooms, no glazing was installed and a correction factor was then applied in the analysis. This scale room was placed under an artificial sky, of the mirror box type that replicated overcast sky conditions. Internal illuminance levels were measured using a 0.5m scale grid on a working plane at 0.7m scale height. The results suggested that with a 2.0m head height and a typical room profile, installation of a roof window will result in an average daylight factor (ADF) that is 0.46 x the glazing to floor area ratio. Therefore in a typical loft conversion with a 45 o roof pitch, from the scale modeling it appears that an average daylight factor (ADF) of 3.5% can be achieved using a roof window with a glazing to floor area ratio of 7.6%. 3.3 Simulation Daylighting simulation tools such as Radiance [12] and FlucsDL [13] can be used to predict daylighting levels and numerical indicators such as ADF. The simulation model was a single loft room with dimensions of 4.0m x 2.5m internal floor plan, 2.5m internal ceiling height and a 2.0m window head height. All the detailed dimensions of the room were consistent with those of the scale room and with those of the full size loft room. In setting up the simulation, the location and orientation together with all of the internal finishes, glazing type and construction materials were either the default values used within the Radiance and FlucsDL simulation environments or were set to be consistent with those of the scale room. In order to be consistent with the data from the calculation and scale modelling, this daylighting data also used simulated

Eco-Architecture: Harmonisation between Architecture and Nature 355 overcast sky conditions. The Radiance simulation work suggested that installation of a roof window would result in an ADF that is 0.43 times the ratio of glazing to floor area. Within a reasonable margin of simulation error, the work with FlucsDL generally supported these findings and showed that a roof window will result in an ADF that is 0.45 times the ratio of glazing to floor area. Therefore, in a typical loft room with a 45 o roof pitch, the simulation work predicted that an ADF of 3.5% could be achieved using a roof window with a ratio of glazing to floor area of between 8.13% (Radiance) and 7.78% (FlucsDL). 3.4 Measurement Comparing these results with measured data from a full size loft room was also possible since all the dimensions and internal finishes were consistent. This loft room also had plan dimensions of 4.0m x 2.5m and a 45 o roof pitch. In this room, the roof window had a glazed area of 0.82m 2 with a head height of 2.0m. Data was collected for the equivalent grid points as used in the scale room. Based on three sets of data collected, the measured ADF was found to be 4.97%. Applying these findings would imply that in order to achieve an ADF of 3.5% with a fixed head height of 2.0m, it would be necessary to install a roof window with a glazing area of 5.83% of the floor area. 3.5 Summary For the typical loft room that was investigated, the combined calculation, experimental, simulation and measurement data in this study seem to suggest rather lower values for the required glazing area than that which has been identified in the majority of the existing guidance material. The findings are: Method ADF:glazing to floor area ratio Calculation 0.35:1 Scale modelling 0.46:1 Simulation 0.43:1 to 0.45:1 Measurement 0.60:1 Averaging these findings and applying equal weighting to each, it appears that a linear relationship of ADF to glazing to floor area ratio of 0.46:1 will generally apply. This means that in a typical loft room, a roof window with a glazing area of 7.6% of the floor area will normally result in an ADF in the region of 3.5%. If the two extreme values based on the calculation and measurement aspects are ignored then an almost identical linear relationship will still apply. This second approach may be justified on the basis of the potential inapplicability of the Littlefair and Plymouth expression to roof windows and the reduced confidence level for the measurement data due to the inevitably limited number of data points associated with one full size loft room.

356 Eco-Architecture: Harmonisation between Architecture and Nature 3.6 Comparison with dormer windows In visually sensitive situations for historic buildings and conservation areas, it is possible to debate the relative merits of dormer windows as compared with the use of small conservation rooflights. To a degree, any conclusions on this topic are somewhat subjective. However, the internal room qualities can be assessed more objectively. A comparative investigation using the well proven Radiance daylighting simulator has previously been published by Dubois et al. [14]. It indicated a relative ADF for a roof window of approximately 3 times that of a dormer window of equal glazed area, which seems to be at odds with the published guidance from a major roof window manufacturer. The work carried out by the authors generally supported the findings described by Dubois et al. Comparative scale room and simulation data was collected for a dormer window using the same techniques as described above for the roof windows. In particular, the ADF for roof window was found to be 2.9 times that of a dormer window of identical roof aperture size and head height. 3.7 Energy consumption As far as the predicted energy consumption is concerned, the available techniques are rather more limited. Given the project duration, it was impractical to consider collecting data from a real loft room over an extended period. Energy consumption data from scale rooms is generally not considered particularly valuable and in any event it was expected the proportionately small change in energy consumption with changes in roof window area would potentially be masked by experimental error and measurement limitations. The use of the Apache thermal simulator appeared to offer the most promising option for predicting annual energy consumption and was applied to a number of test cases. From this simulation, it was apparent that the range of values for annual energy consumption are much less sensitive to changes in roof window area than is the case for daylighting levels. For the typical example that was analysed, varying the roof window area from zero to 20% of the floor area resulted in a maximum variation in energy consumption between 1830kWh and 2330kWh or 21% of the maximum value. The minimum total annual energy consumption was with a glazing to floor area ratio of between 13% and 17%, depending on the orientation of the loft room. 4 Comparison of tactics Calculation of daylighting levels for loft rooms using a single stage method was comparatively rapid but it appears that the usual calculation method will tend to underestimate the daylighting performance of roof windows. The use of scale rooms under artificial sky conditions provided access to daylighting prediction based on variables that would not routinely be possible in full size rooms. Obvious instances of this flexibility included variation in the window area and the ability to change from a dormer to a roof window at will.

Eco-Architecture: Harmonisation between Architecture and Nature 357 The collection of data under the artificial sky represented a very stable and repeatable test environment, without the variability of weather conditions. The scale room was intuitive to use and provided good quality data, albeit typically at a resolution that was limited by the scale of model and the precision to which the model had been constructed. The majority of these observations are consistent with those described by Littler [15]. In contrast, the simulation techniques allowed for finer resolution and provided photo realistic rendering data. In order to obtain valid data, it was important to construct a CAD model that accurately reflected the room under investigation. The simulation tools also required care during the setting up phase to ensure that the results reflected reality. The use of a common data model within the IES Virtual Environment was also valuable as it facilitated a comparison of the Radiance and FlucsDL results for the same CAD model. The measurement activity generally affirmed the qualitative findings from the calculation, scale modelling and simulation work. It also directly related the findings to a real environment and highlighted some of the intrinsic issues in the measurement of lighting levels in a practical context. Although the data set was small, from the measurement work it did seem that in some cases the actual daylighting performance of roof windows might exceed that predicted by scale rooms or using simulation techniques. From a practical point of view, the challenge in the measurement work was one of normalizing the recorded results in order to try and eliminate the effects of any minor variations in aspects such as reflectance and geometry. 5 Design tool A derived objective of the project was the preliminary development of a simple graphical design tool to exploit the research. This tool is intended to assist homeowners and designers in sizing suitable roof windows that optimise both the daylighting and energy consumption aspects. It is based on two graphs that plot the linear change in predicted ADF and the U shaped variation in energy consumption with increasing roof window area. This tool will apply to a reasonably common set of conditions for aspects such as roof pitch, construction type and location. 6 Conclusions This paper makes a case for amending the current guidance on roof window sizing and also the stated relative performance of such windows in comparison with dormer windows. Rather than suggesting 10% of the floor area as the minimum for adequate daylighting, it appears that for typical loft rooms a roof window sized at 7.6% of the floor area will actually provide optimum daylighting levels. Roof windows have been confirmed to provide daylighting levels that are approximately three times better than equivalent dormer windows, which may sometimes encourage their preferential selection for visually sensitive situations. Lastly, in the case of specifically low energy designs and

358 Eco-Architecture: Harmonisation between Architecture and Nature assuming adequate control mechanisms, roof windows having a glazing area that is between 13% and 17% of the floor area may be the most energy efficient solution. References [1] Hopkinson R G, Petherbridge P and Longmore J., Daylighting, Heinemann, London, pp. 59-107, 1966. [2] Littlefair P J., Site Layout Planning for Daylight and Sunlight: a Guide to Good Practice, Building Research Establishment Report, Watford, 1991. [3] CIBSE., Lighting Guide LG10 Daylighting and Window Design, Elsevier, Oxford, pp. 15-68, 1999. [4] Baker N and Steemers K., Energy and Environment in Architecture, Spon, London, pp. 22-25 and pp. 42-52, 2000. [5] Velux Ltd., Loft Conversion Guide, Velux, Glenrothes, pp. 29-31, 2003. [6] Hymers P., Home Conversions, New Holland, London, p. 85, 2003. [7] Velux Ltd., Directors Report and Financial Statements, Velux, Glenrothes, pp. 3-9, 2004. [8] Office of the Deputy Prime Minister, English House Condition Surveys, 2003 and 2005. [9] British Standards Institution, BS8206 Part 2 Code of Practice for Daylighting, BSI, London, pp. 2-7, 1992. [10] Borer P and Harris C., The Whole House Book, Centre for Alternative Technology, Machynlleth, pp. 35-36, 1998. [11] Velux Ltd., Architects Binder, Velux, Glenrothes, 2005. [12] Ward Larson G and Shakespeare R., Rendering with Radiance The Art and Science of Lighting Visualization, Morgan Kaufmann, San Francisco, 1998. [13] Integrated Environmental Solutions Ltd., Virtual Environment Version 5, Integrated Environmental Solutions, Glasgow, 2003. [14] Dubois M C, Grau K, Traberg-Borup S and Johnsen K., Impact of Three Window Configurations on Daylight Conditions: Simulations with Radiance. Internal Report, Danish Building and Urban Research, Hørsholm, Denmark, 2003. [15] Littler J., Test Cells: Do We Need Them? Building and the Environment, volume 28, Pergamon Press, London, p. 222, 1993.