USER S MANUAL AND OPERATING INSTRUCTIONS

Similar documents
USER S MANUAL AND OPERATING INSTRUCTIONS

USER S MANUAL AND OPERATING INSTRUCTIONS

USER S MANUAL AND OPERATING INSTRUCTIONS

USER S MANUAL AND OPERATING INSTRUCTIONS

PORTABLE FORCED AIR HEATERS USER S MANUAL MODEL : DFA-50 DFA-75T DFA-125C DFA-170CV DFA-210CV

USER S MANUAL AND OPERATING INSTRUCTIONS

PORTABLE FORCED AIR HEATERS USER S MANUAL

USER S MANUAL AND OPERATING INSTRUCTIONS

USER S MANUAL PORTABLE FORCED AIR DIESEL HEATERS MODEL : IH75000, IH125000, IH170000

KEROSENE PORTABLE. HEATER operation manual HK400FW

KEROSENE FORCED AIR HEATER User s Manual & Operating Instructions

User s Manual & Operating Instructions

Owner's Manual and Instructions

Type of Input Pump Fuel Tank Fuel Size Weight Model Fue Rating Pressure Capacity Consumptio L x W x H Lbs. (kg)

MODEL NUMBERS: GAU-PH Series CONSUMER: READ AND SAVE THESE INSTRUCTIONS

KEROSENE FORCED AIR HEATER

Model Numbers MHP-135-KFA / MHP-190-KFA / MHP-215-KFA

User s Manual & Operating Instructions

PORTABLE FORCED AIR HEATER

User s Manual & Operating Instructions

KEROSENE FORCED AIR HEATER

Model #s: PT-45-KFA, PT-70T-KFA, PT-125T-KFA, PT-175T-KFA, PT-215T-KFA

PORTABLE FORCED AIR HEATERS

Model Numbers MHP-135-KFA / MHP-190-KFA / MHP-215-KFA

User s Manual & Operating Instructions

KEROSENE FORCED AIR HEATER User s Manual & Operating Instructions

Model #: PT-125-OFR-A

User s Manual and Operating Instructions. Model #: HH-70-SS. CONSUMER: Retain this manual for future reference.

User s Manual & Operating Instructions

DIESEL SPACE HEATER, DIESEL TYPE 30KW CT2142. Instruction & Assembly SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

PORTABLE FORCED AIR HEATER

PORTABLE FORCED AIR HEATER

PORTABLE FORCED AIR HEATER

infrared paraffin / kerosene / diesel heater

PORTABLE FORCED AIR HEATER

User s Manual & Operating Instructions

Dayton Portable Forced Air Heaters

Model Numbers MH-150T-SDR / MH-220T-SDR CONSUMER: READ AND SAVE THESE INSTRUCTIONS. Safety Information

Model Numbers MH-70-SS-A / MH-125-OFR-A CONSUMER: READ AND SAVE THESE INSTRUCTIONS. Safety Information

TRADESMAN K350 & K600

PORTABLE FORCED AIR HEATERS OWNER S MANUAL

Dayton Portable Forced Air Heater

Oil-Fired Heaters. 2E510F, 2E511F, 3E218F, and 3E219F

diesel HEATERS Warning!

AC-70, AC-115 AND AC-165 SPACE HEATERS

model No: ir20.v2 FUSE

PARAFFIN/DIESEL HEATERS

INSTALLER: Leave this manual with the appliance CONSUMER: Retain this manual for future reference.

SPACE WARMER PARAFfIN /

User s Manual & Operating Instructions Model Number MH-150NGT-GFA-A

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

JAZ. Operator s Manual. Diesel/Kerosene Air Heaters JAZ 42 JAZ 80 JAZ 80 W JAZ 125 JAZ 160

Model No: Little Devil II (inc ss)

OPERATING INSTRUCTIONS AND OWNER S MANUAL

1. GENERAL SAFETY RULES

WARNING. PROPANE FORCED AIR HEATER User s Manual & Operating Instructions. Safety Information

space WARMER PARAFFIN / KEROSENE / DIESEL HEATER

OPERATING INSTRUCTIONS AND OWNER S MANUAL

User s Manual & Operating Instructions Model Numbers MH-40-GFA / MH-60V-GFA-A / MH-125V-GFA-A / MH-150V-GFA-A

Model Numbers MH-16-TTC / MH-32-TTC / MH-47-TTC

Model Numbers PT-16-TTC / PT-32-TTC / PT-47-TTC

OPERATING INSTRUCTIONS AND OWNER S MANUAL

DIESEL/PARAFFIN HEATERS

User s Manual & Operating Instructions Model Number MH-375T-GFA-A

OPERATING INSTRUCTIONS AND OWNER S MANUAL

INSTRUCTIONS FOR: SPACE WARMER PARAFFIN / KEROSENE / DIESEL HEATER MODEL NO: AB458.V3

PROPANE FORCED AIR. HEATER operation manual HL060F HL125F

PROPANE CONSTRUCTION HEATERS

User s Manual and Operating Instructions

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

PARAFFIN/DIESEL HEATER

CYLINDER NOT INCLUDED

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER

Model Numbers REM-80V-LPC-O / REM-200V-LPC-O CONSUMER: READ AND SAVE THESE INSTRUCTIONS

DH-Direct Fired Poultry Farm Diesel Heater

User s Manual and Operating Instructions

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

Construction Heater GENERAL HAZARD WARNING. Failure to comply with

Using it in an enclosed space can kill you.

Construction Heater GENERAL HAZARD WARNING

OPERATING INSTRUCTIONS AND OWNER S MANUAL

PROPANE CONSTRUCTION HEATER

PAULIN PRODUCTS INDOOR HEATER

PROPANE CONSTRUCTION HEATER

OPERATING INSTRUCTIONS AND OWNER S MANUAL PORTABLE BUDDY RADIANT HEATER

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

GAS HEATERS MODEL NOS: DEVIL 700, 900/910SS,1600/ 1610SS & 2100 PART NOS: , , , , , &

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

GAS HEATERS Models: Little Devil (inc ss), Devil 650/660(ss), Devil 850/860(ss), Devil 1250/1260(ss), Devil 1850, Devil 3000 & Devil 3150

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

Construction Heater GENERAL HAZARD WARNING

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

THC-175DF INDUSTRIAL / COMMERCIAL SPACE HEATER. Certified to / Certifié à CGA 2.14 M2011 Conforms to / Conforme à ANSI std Z83.

Transcription:

INDOOR/OUTDOOR PRODUCTS KEROSENE PORTABLE FORCED AIR HEATERS USER S MANUAL AND OPERATING INSTRUCTIONS COMPLIES WITH UL733 AND ANSI A0.0-990 CAN/CSA/B0.0-03 AND CSA B0.8-97 MODEL : RMC-KFA50DGD, RMC-KFA75TDGD, RMC-KFA5TDGD-0 RMC-KFA70TDGD-0, RMC-KFA0TDGD-0 Before the first use of this heater, please read this USER S MANUAL very carefully. This USER S MANUAL has been designed to instruct you as to the proper manner in which to assemble, maintain, store, and most importantly, how to operate the heater in a safe and efficient manner. Please keep this manual for future reference. CONSUMER : Retain this manual for future reference. Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 877-7-78 8:30 a.m. - :30 pm CST, Monday - Friday. or email us at customerservice@ghpgroupinc.com

DANGER: IMPROPER USE OF THIS HEATER CAN RESULT IN SERIOUS INJURY OR DEATH FROM BURNS, FIRE, EXPLOSION, ELECTRICAL SHOCK AND/OR CARBON MONOXIDE POISONING. WARNINGS:. RISK OF INDOOR AIR POLLUTION! Use this heater only in well ventilated areas. Provide at least a three-square foot (,800 sq. cm.) opening of fresh outside air for each 00,000 BTU/hr. of heater rating. People with breathing problems should consult a physician before using the heater. Carbon monoxide poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness and/or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have the heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, or those at high altitudes. Never use this heater in living or sleeping areas.. RISK OF BURNS/FIRE/EXPLOSION! NEVER use any fuel other than -K kerosene, # disel/fuel oil in this heater. NEVER use fuel such as gasoline, benzene, paint thinners or other oil compounds in this heater. (RISK OF FIRE OR EXPLOSION) NEVER use this heater where flammable vapors may be present. NEVER refill the heaters fuel tank while heater is operating or is still hot. CAUTION :Hot while in operation. Do not touch. Keep children, clothing and combustibles away from heater. Minimum Clearances: Outlet: 8 feet (50cm) / Sides, top and rear: feet (5cm) NEVER block air inlet (rear) or air outlet (front) of heater. NEVER use duct work in front or behind of heater. NEVER move, handle, service a hot, operating or plugged in heater. NEVER transport heater with fuel in it s tank. When used with an optional thermostat or if equipped with a thermostat heater may start at any time. ALWAYS locate heater on a stable and level surface. ALWAYS keep children and animals away from heater. Bulk fuel storage should be a minimum of 5 ft. from heaters, torches, portable generators or other sources of ignition. All fuel storage should be in accordance with federal, state or local authorities having jurisdiction. 3. RISK OF ELECTRIC SHOCK! Use only the electrical power (voltage and frequency) specified on the model plate of the heater. Use only a three-prong, grounded outlet and extension cord. ALWAYS install the heater so that it is not directly exposed to water spray, rain, dripping water or wind. ALWAYS unplug the heater when not in use. PROPOSITION 5 WARNING: Fuels used in gas, wood-burning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. MASSACHUSETTS RESIDENTS: Massachusetts state law prohibits the use of this heater in any building which is used in whole or in part for human habitation. Use of this heating device in Massachusetts requires local fire dept. permit (M.E.L.C. 8, Section 0A.) CANADIAN RESIDENTS: Use of this heater shall be in accordance with authorities having jurisdiction and CSA Standard B39. NEW YORK CITY RESIDENTS: For use only at construction sites in accordance with applicable NYC codes under NYCFD certificate of approval # 503 and 5037.

CONTENTS OF USER S MANUAL ITEM PAGE # PRECAUTIONS - SAFETY GUIDE. INTRODUCTION. FEATURES 3. UNPACKING AND ASSEMBLY. KEROSENE (-K OR NO. FUEL OIL) 5. OVERVIEW OF HEATER DESIGN 7. FUELING YOUR HEATER 8 7. OPERATION 8 8. LONG TERM STORAGE OF YOUR HEATER 9 9. MAINTENANCE 0 0. REPLACING FUSE. TROUBLE SHOOTING GUIDE 5. WIRING DIAGRAM 3. SPECIFICATIONS 7. EXPLODED PARTS DRAWING 8 5. PARTS LIST. INTRODUCTION Please read this USER S MANUAL carefully. It will show you how to assemble, maintain, and operate the heater safely and efficiently to obtain full benefits from its many built-in features.. FEATURES Front Guard Hot Air Outlet Lower Shell Upper Shell Handle Fan Guard Fuel Tank Side Cover Lamp Thermostot Knob (75TDGD Model Only) Power/Reset Switch Power Cord (Piggy Back, 75TDGD Model Only) Figure. RMC-KFA50DGD/75TDGD MODELS Fuel Gauge Fuel Cap

Hot Air Outlet Shell Lower Snap Fit Front Handle Upper Shell Snap Fit Rear Handle Cord Wrap Fuel Gauge Fuel Cap Side Cover Lamp Thermostot Knob Room Temp. Display (70TDGD-0 Model Only) Power/Reset Switch 0 Flat Free Wheel BTU Control Switch Pressure Gauge Fan Guard Power Cord (Piggy Back) Fuel Drain Bolt Figure. RMC-KFA5/70TDGD-0 MODELS Electric Outlet Snap Fit Front Handle Hot Air Outlet Shell Lower Upper Shell Snap Fit Rear Handle Cord Wrap Fuel Gauge Fuel Cap Side Cover Lamp Thermostot Knob Room Temp. Display Power/Reset Switch 0 Flat Free Wheel Figure 3. RMC-KFA0TDGD-0 MODEL 3 BTU Control Switch Pressure Gauge Fan Guard Power Cord Fuel Drain Bolt

3. UNPACKING AND ASSEMBLY. REMOVE THE HEATER AND ALL PACKING MATERIALS FROM THE BOX. (Fig. and 5) NOTE : Save the shipping carton and packing materials for future storage. RMC-KFA50DGD RMC-KFA75TDGD RMC-KFA5TDGD-0 RMC-KFA70TDGD-0 RMC-KFA0TDGD-0 Snap Fit Front Leg No Yes Yes Wheel No Yes Yes Threaded Axle No Yes Yes Snap Fit front Handle No Yes Yes Snap Fit Rear Handle No Yes Yes Handle Yes No No Cord Wrap Yes Yes Yes Hardware kit : HW-KFA000 Yes No No Hardware kit : HW-KFA05 No Yes Yes Figure. RMC-KFA50DGD/75TDGD MODELS Handle Hardware Kit HW-KFA000 Figure 5. RMC-KFA5/70/0TDGD-0 MODELS Bushings Cap Nuts Wheels (0 Flat Free) Hardware Kit : HW-KFA05 Snap Fit Front Handle Snap Fit Rear Handle Snap Fit Front Leg Threaded Axle

. ASSEMBLY For RMC-KFA50DGD/75TDGD Models only (Assembly time for this product is 3 minutes) Tools Required Medium Phillips Screwdriver. ) Lift front guard for arrow direction and make sure that guard s wedged portion fits into the slit hole on the upper housing. ) Align the holes in the upper housing with two mounting holes on the handle as shown in Figure. 3) Secure handle with Screws with provided. Handle Screw Front Guard Wedged Portion Slit Hole Figure. Assembling Handle For RMC-KFA5/70/0TDGD-0 Models only (Assembly time for this product is 0 minutes) Tools Required 3/ inch Socket or Adjustable Wrench ) Align and insert snapfit front leg in to the front section of the bottom leg and wheel support. You will need to depress the metal buttons when installing. See Figure 7 below. ) Slide threaded axle through the rear sectioon of the bottom leg and wheel support. 3) Slide one axle bushing on to each side of the axle. Slide one wheel on to each side of the axle. Attach one cap nut on to each side of the threaded axle and tighten well. ) Align and insert snapfit front and rear handles to the top support handle. You will need to depress the metal buttons on each handle when installing. See Figure 7 below. Snap Fit Front Handle Button Snap Fit Rear Handle Hole Top Handle Support Snap Fit Front Leg Bottom Leg And Wheel Support Wheel Cap Nut Threaded Axle Bushing Figure 7. Assembling Handles & Wheels CAUTION : DO NOT OPERATE heater without support frame assembled to tank. NOTE : Heater should be inspected before each use, and at least annually by a qualified service person. 5

. KEROSENE (-K) For optimal performance of this heater, it is strongly suggested that -K kerosene be used. -K kerosene has been refined to virtually eliminate contaminants, such as sulpher. Which can cause a rotten egg odor during the operation of the heater. However, # diesel/fuel oil may also be used if -K kerosene is not available. Be advised that these fuels do not burn as clean as -K kerosene, and care should be taken to provide more fresh air ventilation to accomodate any added contaminants that may be added to the heated space. KEROSENE SHOULD ONLY BE STORED IN A BLUE CONTAINER THAT IS CLEARLY MARKED KEROSENE. NEVER STORE KEROSENE IN A RED CONTAINER. Red containers are associated with gasoline. NEVER store kerosene in the living space. Kerosene should be stored in a well ventilated place outside the living area. NEVER use any fuel other than -K kerosene (# diesel and # oil are acceptable substitutes) NEVER use fuel such as gasoline, benzene, alcohol, white gas, camp stove fuel, paint thinners, or other oil compounds in this heater. These are volatile fuels that can cause an explosion or uncontrolled flames. NEVER store kerosene in direct sunlight or near a source of heat. NEVER use kerosene that has been stored from one season to the next. Kerosene deteriorates over time. OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER.

5. OVERVIEW OF HEATERS DESIGN Fuel System : This heater is equipped with an electric air pump that forces air through the air line connected to the fuel intake and then through a nozzle in the burner head. When the air passes in front of the fuel intake it causes fuel to rise from the tank and into the burner nozzle. This fuel and air mixture is then sprayed into the combustion chamber in a fine mist. Sure Fire Ignition : The electronic ignitor sends voltage to a specially designed spark plug. The spark plug ignites the fuel and air mixture described above. The Air System : The heavy duty motor turns a fan that forces air into and around the combustion chamber. Here the air is heated and then forced out the front of the heater. The Safety System : A. Temperature Limit Control : This heater is equipped with a Temperature Limit Control designed to turn off the heater should the internal temperature rise to an unsafe level. If this device activates and turns your heater off it may require service. MODELS Internal Shut-Off Temp. Reset Temperature Plus/Minus 0 Degrees Plus/Minus 0 Degrees RMC-KFA50DGD/75TDGD 7 F/80 C F/50 C RMC-KFA5/70TDGD-0 30 F/0 C 9 F/90 C RMC-KFA0TDGD-0 9 F/90 C 0 F/0 C Once the temperature falls below the reset temperature you will be able to start your heater. B. Electrical System Protection : This heaters electrical system is protected by a fuse mounted to the PCB assembly that protects it and other electrical components from damage. If your heater fails to operate check this fuse first and replace as needed. FUSE TYPE: All Models 5 volt / 8 amps C. Flame-Out Sensor : Utilizes a photocell to monitor the flame in burn chamber during normal operation. It will cause the heater to shut-off should the burner flame extinguish. 7

. FUELING YOUR HEATER NEVER FILL THE HEATER FUEL TANK IN THE LIVING SPACE : FILL THE TANK OUTDOORS. DO NOT OVERFILL YOUR HEATER AND BE SURE HEATER IS LEVELED. IMPORTANT NOTICE REGARDING FIRST IGNITION OF HEATER : The first time you light the heater, it should be done outdoors. This allows the oils, etc. used in manufacturing the heater to burn off outside. WARNING!! : NEVER REFILL HEATER FUEL TANK WHEN HEATER IS OPERATING OR STILL HOT. 7. OPERATION A.) VENTILATION RISK OF INDOOR AIR POLLUTION/USE HEATER ONLY IN WELL VENTILATED AREAS. Provide a fresh air opening of at least three square feet (,800 sq. cm) for each 00,000 BTU/Hr. rating. Provide extra fresh air if more heaters are being used. Example : A RMC-KFA0TDGD-0 heater requires one of the following: a two-car garage door raised six inches (5. cm) a single-car garage door raised nine inches (.8 cm) two, thirty-inch (7.0 cm) windows raised fifteen inches (38. cm) B.) OPERATION TO START HEATER. Fill fuel tank with kerosene or No. fuel oil.. Attach fuel cap. 3. Plug power cord of heater into three-prong, grounded extension cord. Extension cord must be at least six feet long. Extension Cord Wire Size Requirements to 0 feet (.8 to 3 meters) long, use 8 AWG conductor. to 00 feet (3. to 30.5 meters) long, use AWG conductor. 0 to 00 feet (30.8 to meters) long, use AWG conductor.. Turn THERMOSTAT CONTROL knob to desired setting (setting range : 0 F ~ 0 F) (RMC-KFA75TDGD/RMC-KFA5/70/0TDGD-0 Models Only) 5. Push BTU control Switch to desired level High or LOW (See Figure 8.) (RMC-KFA5/70/0TDGD-0 Models Only). Push Power Switch to ON position, Power lndicator Lamp will light and heater will start. NOTE : Room Temperature display explanations are as follows: (RMC-KFA70/0TDGD-0 Models only) When the room temperature is less 0, the LED display will show Lo When room temp is between 0 and 99, the number shown on the display is the current room temperature. When room temperature is greater than 99, the LED display will show Hi If heater does not start, the thermostat setting may be too low, turn thermostat Control Knob to higher position to start heater. If heater still does not start, turn power switch to OFF and then to ON position. If heater still does not start, see Troubleshootiong Guide on page5. NOTE : User can Select to operate the heater on two different BTU levels(high or Low). The BTU level can be selected before turning the unit on, or while it is in operation by pushing the BTU control switch. Lamp Lamp Room Temp. Display BTU Control Switch BTU Control Switch Push to HIGH Thermostat Control Knob Power/Reset Switch (75TDGD/5TDGD-0 MODELS ONLY) RMC-KFA50DGD/75TDGD/ 5TDGD-0 Models Thermostat Control Knob Power/Reset Switch RMC-KFA70/0TDGD-0 Models Fan Guard Figure 8. Controls for All Models 8 Push to LOW

NOTICE : The major electrical components of this heater are protected by a safety fuse mounted to the PCB board. If your heater fails to start, check this fuse first and replace as necessary. You should also check your power source to insure that proper voltage and frequency are being supplied to the heater. TO STOP HEATER. Turn switch to OFF and unplug power cord. TO RESTART HEATER.Wait 0 seconds after stopping heater.. Repeat steps under to start heater. EXTRA ELECTRIC OUTLET & PIGGYBACK POWER CORD Cover WARNING : SHOCK HAZARD! Always cover electric outlet when not in use. Don t plug and use a appliance more than 0V/0Hz 5A current in this outlet Outlet RMC-KFA0TDGD-0 Model Only Figure 9. Electric Outlet Cover Outlet RMC-KFA75TDGD/5/70TDGD-0 Models only 8. LONG TERM STORAGE OF YOUR HEATER FUEL TANK DRAIN. Drain fuel tank through fuel cap opening. (For RMC-KFA50DGD/75TDGD Models Only). Remove fuel drain bolt from rear bottom side of fuel tank using 3/ socket or adjustable wrench and drain. (For RMC-KFA5/70/0TDGD-0 Models Only. See Figure 0) 3. Using a small amount of kerosene, swirl and rinse the inside of the tank. NEVER mix water with the kerosene as it will cause rust inside the tank. Pour the kerosene out making sure that you remove it all. IMPORTANT : Do not store kerosene over summer months for use during next heating season. Using old fuel could damage heater.. Reinstall fuel cap. Properly dispose of old and dirty fuel. (For RMC-KFA50DGD/75TDGD Models Only) 5. Reinstall fuel drain bolt to Fuel tank and tighten firmly using 3/ socket or adjustable wrench. (For RMC-KFA5/70/0TDGD-0 Models Only. See Figure 0) IMPORTANT : Before reinstalling the fuel drain bolt, make sure the seal is on the bolt. If the seal is not used the bolt cannot be installed correctly and the fuel tank will leak. Seal Fuel Drain Bolt Figure 0. Fuel Drain Bolt. Store heater in dry well ventilated area. Make sure storage place is free of dust and corrosive fumes. 7. Store the heater in the original box with the original packing material and keep the USER S MANUAL with the heater. 9

9. MAINTENANCE WARNING!! : NEVER SERVICE HEATER WHILE IT IS PLUGGED IN OR WHILE HOT! USE ORIGINAL EQUIPMENT REPLACEMENT PARTS. Use of third party or other alternate components will void warranty and may cause unsafe operating conditions. A.) FUEL TANK FLUSH EVERY 00 HOURS OF OPERATION OR AS NEEDED (SEE STORAGE, PAGE 9) B.) AIR INTAKE FILTER WASH AND DRY WITH SOAP AND WATER EVERY 500 HOURS OF OPERATION OR AS NEEDED. - Remove screws along each side of heater using medium phillips screwdriver. - Lift upper shell off. - Remove fan guard. - Wash or replace air intake filter. - Reinstall fan guard and upper shell. C.) AIR OUTPUT FILTER, LINT FILTER REPLACE EVERY 500 HOURS OF OPERATION OR ONCE A YEAR. - Remove upper shell and fan guard (See Air Intake Filter). - Trun Air pressure gauge counter-clock wise and remove. - Remove end filter cover screws using medium phillips screwdriver. - Remove end filter cover. - Replace air output and lint filter. - Reinstall end filter cover and air pressure gauge. - Reinstall fan guard and upper shell. D.) FAN BLADES CLEAN EVERY SEASON OR AS NEEDED. - Remove upper shell (See Air Intake Filter). - Use M allen wrench to loosen set screw which holds fan blade to motor shaft. - Slip fan blade off motor shaft. - Clean fan blade using a soft cloth moistened with kerosene or solvent. - Dry fan blade thoroughly. - Reinstall fan blade on motor shaft. Place fan blade hub flush with end of motor shaft. - Place set screw on flat of shaft. Tighten set screw firmly (0-50 inch-pounds/.5-5. N-m). - Reinstall upper shell. 0 Lint Filter Flush Figure. Air Intake Filter Access Pressure Gauge Air Intake Filter Figure. Air Outprt Filter Access Fan Screw Upper Shell Set screw Motor Shaft Blade Motor Screw Figure 3. Fan Assembly Air Intake Filter Fan Guard Air Output Filter End filter cover

E.) NOZZLE REMOVE DIRT IN NOZZLE AS NEEDED (SEE PAGE ). (For RMC-KFA50DGD/75TDGD/5/70TDGD-0 Models Only) - Remove upper shell (See page 0). - Remove fan blade (See page 0). - Remove fuel and air line hoses from burner head. - Remove ignitor wire from spark plug. - Remove three screws using medium phillips screwdriver and remove burner head from combustion chamber. - Remove spark plug from burner head using medium phillips screwdriver. - Carefully remove nozzle from burner head using 5/8 socket wrench. - Blow compressed air through face of nozzle. (this will remove any dirty in nozzle) - Reinstall nozzle into burner head and tighten firmly. (80~0 inch-pounds) - Reinstall spark plug in burner head. - Attach burner head to combustion chamber. - Attach ignitor wire to spark plug. - Attach fuel and air line hoses to burner head. - Reinstall fan blade and upper shell. (For RMC-KFA0TDGD-0 Model Only) - Remove upper shell (See page 0). - Remove fan (See page 0). - Remove fuel and air line hoses from adaptor-nozzle. - Remove ignitor wire from spark plug. - Remove four screws using medium phillips screwdriver and remove burner-bracket from combustion chamber. - Remove spark plug from burner head using medium phillips screwdriver. - Carefully remove nozzle from adaptor-nozzle using 5/8 socket wrench. - Blow compressed air through face of nozzle. (this will remove any dirt in nozzle) - Reinstall nozzle into adaptor-nozzle and tighten firmly. (80~0 inch-pounds) - Reinstall spark plug in spark-bracket. - Attach burner-bracket to combustion cahmber. - Attach ignitor wire to spark plug. - Attach fuel and air line hoses to adaptor-nozzle. - Reinstall fan blade and upper shell. Nozzle Face Nozzle Fuel Line Fitting Air Line Fitting Fuel Line Air Line Fuel Line Hose Air Line Hose Combustion Chamber Screw Ignitor Wire Burner Head Spark Plug Burner Head Figure. Nozzle Replacement Combusion chamber Burner Bracket Spark Plug Ignitor Wire Screw Bracket Burner Nozzle Face Nozzle Spark Plug Bracket Spark Figure 5. Nozzle Replacement

F.) SPARK PLUG CLEAN AND REGAP EVERY 00 HOURS OPERATION OR REPLACE AS NEEDED. (For RMC-KFA50DGD/75TDGD/5/70TDGD-0 Models Only) - Remove upper shell (See page 0). - Remove fan (See page 0). - Remove ignitor wire from spark plug. - Remove spark plug from burner head using medium phillips screwdriver. - Clean and regap spark plug electrodes to 3.5mm gap. - Reinstall spark plug in burner head. - Attach ignitor wire to spark plug. - Reinstall fan and upper shell. (For RMC-KFA0TDGD-0 Model Only) - Remove upper shell (See page 0). - Remove fan (See page 0). - Remove ignitor wire from spark plug. - Remove spark plug from spark-bracket using medium phillips screwdriver. - Clean and regap spark plug electrodes to 3.5mm gap. (0.38 ) - ReInstall spark plug in spark-bracket. - Attach ignitor wire to spark plug. - Reinstall fan and upper shell. G.) PHOTOCELL CLEAN PHOTOCELL ANNUALLY OR AS NEEDED. - Remove upper shell (See page 0). - Remove fan (See page 0). - Remove photocell from it s mounting. Clean photocell lens with cotton swab. TO REPLACE: - Remove side cover screws using medium phillips screwdriver. - Disconnect switch wires from power switch and remove side cover. - Disconnect wires from circuit board and remove photocell. - Install new photocell and connect wires to circuit board. - Replace switch wires to power switch and side cover. - Replace fan and upper shell. Incorrect GAP Side Cover Power Switch Screw Photocell Wire Brocket Spark Plug Ignitor wire Burner Head Spark Plug Figure. Spark Plug Regap Bracket Burner Bracket Spark Ignitor Wire Spark Plug Figure 7. Spark Plug Regap Correct Switch Wires Photocell Lens Figure 8. Photocell Replacement

H.) FUEL FILTER CLEAN OR REPLACE TWICE A HEATING SEASON OR AS NEED. - Remove side cover screws using medium phillips screwdriver. - Disconnect switch wires from power switch and remove side cover. - Pull fuel line off fuel filter neck. - Turn fuel filter 90 to counter clockwise and pull to remove (RMC-KFA50DGD/75TDGD Models only). - Turn fuel filter 90 to clockwise and pull to remove (RMC-KFA5/70/0TDGD-0 Models only). - Wash fuel filter with clean fuel and replace in tank. - Attach fuel line to fuel filter neck. - Replace switch wires to power switch. - Reinstall side cover. Screw Side Cover Fuel Filter Fuel line Switch Wires Power Switch I.) PUMP PRESSURE ADJUSTMENT NOTE: If the pump pressure needs to be adjusted, make sure the heater is running on the HIGH BTU setting. - Push the BTU CONTROL Switch to HIGH. (See Operation, page 8, RMC-KFA5/70/ 0TDGD-0 Models only) - Remove Pressure Gauge Plug from End Filter Cover. Install accessory Pressure Gauge. (RMC-KFA50DGD/75TDGD Models only) - Start heater (See Operation, page 8) Allow motor to reach full speed - Adjust pressure (Using a flat blade screwdriver) Turn relief valve to clockwise to increase pressure. Turn relief valve to counter clockwise to decreasepressure. - Stop heater (See Operation, page 8) Pump Pressure MODEL High BTU level Low BTU level RMC-KFA50DGD RMC-KFA75TDGD RMC-KFA5TDGD-0 RMC-KFA70TDGD-0 RMC-KFA0TDGD-0 3.8 psi N/A 3.8 psi N/A 5.5 psi 3.5 psi.5 psi.5 psi 8.5 psi.5 psi NOTE : USE ONLY ORIGINAL EQUIPMENT REPLACEMENT PARTS. Use of alternate or third party components will void any warranty and may cause unsafe operating condition. Figure 9. Fuel Filter Replacement Flat blade Screw driver End Filter Cover. Pressure Gauge Plug Pressure Gauge Relief Valve RMC-KFA50DGD/75TDGD Models Only Pressure Gauge BTU Control Switch Relief Valve RMC-KFA5/70/0TDGD-0 Models only Figure 0. Adjusting Pump Pressure 3

0. REPLACING FUSE NOTICE : This heater is fuse protected. If your heater fails to ignite, DO NOT RETURN YOUR HEATER TO THE STORE. Please follow the simple instruction below to inspect and change the fuse. PROCEDURE FOR REPLACING FUSE WARNING : SHOCK HAZARD To prevent personal injury, unplug the power cord before replacing fuse.. Unplug heater.. Remove side cover screws using medium phillips screw driver. 3. Disconnect switch wires from power switch.. Remove fuse from fuse holder.(see Figure.) 5. Replace fuse with enclosed fuse. WARNING : FIRE HAZARD To avoid fire, Do not substitute with a higher or lower current rating.. Replace switch wires to power switch. 7. Replace side cover. NOTE : Specified fuse rating : AC 5/8A Fuse Fuse Holder RMC-KFA75TDGD/5/70/0TDGD-0 Models Screw Side Cover Power Switch Switch Wire Fuse Fuse Holder Figure. Replacing Fuse RMC-KFA50DGD

. TROUBLE SHOOTING GUIDE TROUBLE Heater ignites but MAIN PCB assembly shuts heater off after a short period of time. (Indicator Lamp is flickering and room temp. display indicates " E ") Heater will not ignite but motor runs for a short period of time.(indicator Lamp is flickering and room temp.display indicates " E ") Fan does not turn when heater is plugged in and power switch was in the " ON " Position. (Indicator Lamp is on or flickering) (Indicator Lamp is flickering and room temp. display indicates "E") (Indicator Lamp is flickering and room temp. display indicates "E3") Heater will not turn-on (Indicator Lamp is off) POSSIBLE CAUSE. Wrong pump pressure. Dirty Air Output,Air Intake or Lint Filter. 3. Dirty Fuel Filter.. Dirt in Nozzle. 5. Dirty Photocell Lens.. Photocell Assembly not Properly installed.(not seeing the flame) 7. Bad electrical connection between photocell and MAIN PCB assembly. 8. Defective Photocell.. No fuel in tank.. Wrong pump pressure. 3. Carbon deposits on spark plug and/or improper gap.. Dirty fuel filter. 5. Dirt in Nozzle.. Water in fuel tank. 7. Bad electrical connection between ignitor and MAIN PCB assembly. 8. Ignition wire is not attached to spark plug.. Thermostat setting is too low.. Bad electrical connection between motor and MAIN PCB assembly.. Room Temp. sensor disconnected.. Sensor Failure.. Thermostat switch failure.. Temperature limit safety device is overheated.. No electrical power 3. Blown fuse.. Bad electrical connection between temperature limit safety device and PCB board. 5 CORRECTIVE ACTION. See Pump Pressure Adjustment, Page 3.. See Air Output, Air intake and Lint Filters, page 0. 3. See Fuel Filter, Page 3.. See Nozzle, Page. 5. Clean Photocell Lens, Page.. Make sure photocell boot is properly seated in bracket, Page. 7. Check electrical components See wiring diagram, Page. 8. Replace Photocell, Page.. Fill tank with kerosene.. See Pump Pressure Adjustment, Page 3. 3. See Spark Plug, Page.. See Fuel Filter, Page 3. 5. See Nozzle, Page.. Flush fuel tank with clean kerosene, Page 9. 7. Check electrical components See wiring diagram, Page. 8. Attach ignition wire to spark plug. See Spark Plug, Page.. Turn thermostat control knob to a higher setting.. Check electrical connections, See Wiring Diagram, Page.. Reconnect sensor. See Wiring diagram, Page.. Replace sensor. See Wiring diagram, Page.. Replace switch. See Wiring diagram, Page.. Turn power switch to "OFF" and allow to cool (about 0 min.). Check to insure heater cord and extension cord are plugged in. Check power supply. 3. Replace safety fuse in PCB board.. Check electrical connections See Wiring Diagram, Page.

. WIRING DIAGRAM A) WIRING DIAGRAM (RMC-KFA50DGD Model) B) WIRING DIAGRAM (RMC-KFA75TDGD/5/70TDGD-0 Models) /G WIRE MODEL CAPACITOR COLOR BLACK 75TDGD uf/30vac RED 5TDGD-0 BLACK 30uF/50VAC WHITE BLACK 70TDGD-0 30uF/50VAC BLUE C) WIRING DIAGRAM (RMC-KFA0TDGD-0 Model)

3. SPECIFICATIONS RMC-KFA50DGD/75TDGD Models D W H RMC-KFA5/70/0TDGD-0 Models 5TDGD-0.9"(,03 mm).5"(57 mm) 3."(8 mm) 70TDGD-0 0TDGD-0 7."(,05 mm) 3."(587 mm) 33.5"(850 mm) MODEL BTU/Hr. Fuel Consumption - Gal./Hr(./Hr) Fuel Tank Capacity - Gal.( ) Pump Pressure PSI(kgf/ Volt/Hz Amps. Phase Size(D W H), Inch( ) Weight Lbs.( ) HIGH LOW HIGH LOW HIGH LOW RMC-KFA50DGD RMC-KFA75TDGD RMC-KFA5TDGD-0 RMC-KFA70TDGD-0 RMC-KFA0TDGD-0 75,000 5,000 70,000 0,000 N/A 00,000 35,000 70,000 0.57(.) 0.95(3.0).30(.9).0(.0) N/A 0.7(.90).0(3.79).30(.9) 5.0(8.9) 0.0(37.9) 3.0(9.) 3.0(9.) 3.8(0.7) 5.5(0.39).5(0.) 8.5(0.0) N/A 3.5(0.5).5(0.3).5(0.) 0Vac/0hz 0Vac/0hz 0Vac/0hz 0Vac/0hz..5 3. 3.7 50,000 N/A 0.38(.) N/A 5.0(8.9) 3.8(0.7) N/A 0Vac/0hz. 3.0.7.7 (83 97 ).0(.8) 3.0.7.7 (83 97 ).0(.8).9.5 3. (,03 57 8) 53.(.) 7. 3. 33.5 (,05 587 850) 59.3(.9) 7. 3. 33.5 (,05 587 850) 5.0(9.5) 7

. EXPLODED PARTS DRAWING (RMC-KFA50DGD/75TDGD Models Only) NOTE : SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS. 8

. EXPLODED PARTS DRAWING (RMC-KFA5/70TDGD-0 Models Only) NOTE : SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS. 9

. EXPLODED PARTS DRAWING (RMC-KFA0TDGD-0 Model Only) NOTE : SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS. 0

5. PARTS LIST (RMC-KFA50DGD/75TDGD Models Only) KEY NO. 3 5 7 8 9 0 3 5 7 8 9 0 3 - - -3 - -5 - -7-8 -9-0 - 5 7 7-7- 7-3 DESCRIPTION Fuel Tank Assembly Fuel Drain-Bolt Fuel Gauge Fuel Filter Assembly Fuel Cap Cord Bushing Power Cord Thermostat Button Support Display P.C.B Assembly Shell Lower Clip Nut Bushing-Grommet(S) Bushing-Grommet(L) Air-Line Temperature Limit Assembly Flange-Screw Chamber Assembly Photocell Bracket Screw-BH Photocell Assembly Burner Head Assembly Burner Head Nozzle Washer-Nozzle Seal Spring-Nozzle Seal O-Ring Nipple Nipple Washer-Fiber Spark Plug Washer-Spring Bolt-Flange Fuel Line Motor and Pump Assembly Motor Capacitor Motor Support RMC-KFA50DGD 5-000-00-5-00-00 55-0005-00 5-0003-00 37-003-00 3980-003-00-373-008-00 5A-003-00 3-009-08 39-005-00 33-08-00 33-00-00 33-0-00 33-0007-00 53-0003-00 39-005-00 5-009-00 39-005-00 33-059-00 3-008-00 *SP-KFA007 5-000-00 353-005-00 *SP-KFA0 39-00-00 33-000-00 33-000-00 35-0039-00 35-000-00 39-007-00 *SP-KFA008 3-0009-00 39-003-00 39-005-00 33-0009-00 5-0050-00 3970-003-00 380-0-00 3-089-00 PART NO. RMC-KFA75TDGD 5-0007-00-5-009-00 55-0005-00 5-0003-00 37-003-00 3980-077-00 38C0-005-00 - - 3-009-08 39-005-00 33-08-00 33-00-00 33-0-00 33-0007-00 53-0003-00 39-005-00 5-003-00 39-005-00 33-059-00 3-008-00 *SP-KFA007 5-00-00 353-005-00 *SP-KFA07 39-00-00 33-000-00 33-000-00 35-0039-00 35-000-00 39-007-00 *SP-KFA008 3-0009-00 39-003-00 39-005-00 33-0009-00 5-0050-00 3970-003-00 380-0-00 3-089-00 Quantity 3

5. PARTS LIST (RMC-KFA50DGD/75TDGD Models Only) KEY NO. 7-7-5 7-7-7 7-8 7-9 7-0 7-7- 7-3 7-7-5 7-7-7 7-8 7-9 7-0 7-8 9 30 3 3 33 3 35 3 37 38 39 0 3 5 DESCRIPTION Nut-Hex Holder Capacitor Pump Body Bolt-BH Special Rotor Blade Insert End Pump Cover Nipple Lint Filter Bolt Flange Output Filter End Filter Cover Ball Spring Adjusting Screw Bolt Flange Intake Filter Fan Assembly Bolt Headless Hex Socket Pressure Gauge Main P.C.B Assembly Screw-THS Ignitor Side Cover-Right Power Switch Window Display Side Cover-Left Shell Upper Clip Nut Fan Guard Front Guard RMC-KFA50DGD 33-003-00-35-00-00 3-098-00 *SP-KFA000 See SP-KFA000 See SP-KFA000 353-0008-00 33-05-00 *SP-KFA005 39-00-00 See SP-KFA005 3-009-00 *SP-KFA00 See SP-KFA00 See SP-KFA00 39-00-00 See SP-KFA005 39-005-00 5-000-00 33-000-00 5A-009-00 3-00-00 39E0-0008-00 3-09- 39A0-09-00-39-005-00 3-090-00 39-005-00 3-03-08 33-08-00 3-0050-00 39-005-00 35-00-00 PART NO. RMC-KFA75TDGD 33-003-00-35-00-00 3-098-00 *SP-KFA000 See SP-KFA000 See SP-KFA000 353-0008-00 33-05-00 *SP-KFA005 39-00-00 See SP-KFA005 3-009-00 *SP-KFA00 See SP-KFA00 See SP-KFA00 39-00-00 See SP-KFA005 39-005-00 5-0009-00 33-000-00 - - 5A-00-00 3-00-00 39E0-0008-00 3-03- 39A0-09-00-39-005-00 3-0350-00 39-005-00 3-03-08 33-08-00 3-0050-00 39-005-00 35-00-00 Quantity FOR TECHNICAL ASSISTANCE SEE YOUR LOCAL RETAILER OR CONTACT US AT: Phone : -877-7-78

5. PARTS LIST (RMC-KFA5/70TDGD-0 Models Only) KEY NO. 3 5 7 8 9 0 3 5 7 8 9 0 - - -3 - -5 - -7-8 -9-0 - 3 5 5-5- 5-3 5-5-5 DESCRIPTION Fuel Tank Assembly Fuel Drain-Bolt Fuel Gauge Fuel Filter Assembly Fuel Cap Cord Bushing Power Cord Thermostat Shell Lower Clip Nut Bushing-Grommet(S) Bushing-Grommet(L) Air-Line Temperature Limit Assembly Flange-Screw Chamber Assembly Bracket Photocell Screw-BH Photocell Assembly Burner Head Assembly Burner Head Nozzle Washer-Nozzle Seal Spring-Nozzle Seal O-Ring Nipple Nipple Washer-Fiber Spark Plug Washer-Spring Bolt-Flange Fuel Line Motor and Pump Assembly Motor Capacitor Motor Support Nut-Hex Capacitor Holder PART NO. RMC-KFA5TDGD-0 RMC-KFA70TDGD-0 5-0008-00 5-0009-00 39-007-00 39-007-00 5-0050-00 5-005-00 55-000-00 55-000-00 5-0003-00 5-0003-00 37-003-00 37-003-00 3980-077-00 3980-077-00 38C0-005-00 38C0-005-00 3-00-08 3-0-08 39-005-00 39-005-00 33-08-00 33-08-00 33-00-00 33-00-00 33-0-00 33-0-00 33-000-00 33-000-00 53-000-00 53-000-00 39-005-00 39-005-00 5-00-00 5-009-00 39-005-00 39-005-00 33-059-00 33-059-00 3-008-00 3-008-00 *SP-KFA007 *SP-KFA007 5-000-00 5-0009-00 353-0007-00 353-0009-00 *SP-KFA003 *SP-KFA00 39-00-00 39-00-00 33-000-00 33-000-00 33-000-00 33-000-00 35-000-00 35-000-00 35-000-00 35-000-00 39-007-00 39-007-00 *SP-KFA009 *SP-KFA009 3-0009-00 3-0009-00 39-003-00 39-003-00 39-005-00 39-005-00 33-0008-00 33-0008-00 5-007-00 5-008-00 3970-009-00 3970-0033-00 380-03-00 380-03-00 3-005-00 3-005-00 33-003-00 33-003-00 33-05-00 33-05-00 Quantity 3 3

5. PARTS LIST (RMC-KFA5/70TDGD-0 Models Only) KEY NO. 5-5-7 5-8 5-9 5-0 5-5- 5-3 5-5-5 5-5-7 5-8 5-9 5-0 5-7 8 9 30 3 3 33 3 35 3 37 38 39 0 DESCRIPTION Pump Body Bolt-BH Special Rotor Blade Insert End Pump Cover Nipple Lint Filter Bolt Flange Output Filter End Filter Cover Ball Spring Adjusting Screw Bolt Flange Intake Filter Fan Assembly Bolt Headless Hex Socket Pressure Gauge BTU Control Switch Main P.C.B Assembly Screw-THS Ignitor Side Cover-Right Power Switch Window Display Side Cover-Left Shell Upper Fan Guard PART NO. RMC-KFA5TDGD-0 RMC-KFA70TDGD-0 3970-009-00 35-00-00 3-098-00 3-098-00 *SP-KFA000 *SP-KFA000 See SP-KFA000 See SP-KFA000 See SP-KFA000 See SP-KFA000 353-0008-00 353-0008-00 33-05-00 33-05-00 *SP-KFA005 *SP-KFA005 39-00-00 39-00-00 See SP-KFA005 See SP-KFA005 3-007-00 3-007-00 *SP-KFA00 *SP-KFA00 See SP-KFA00 See SP-KFA00 See SP-KFA00 See SP-KFA00 39-00-00 39-00-00 See SP-KFA005 See SP-KFA005 39-005-00 39-005-00 5-000-00 5-0007-00 33-000-00 33-000-00 370-009-00 370-009-00 5-0070-00 5-0070-00 5A-00-00 5A-003-00 3-00-00 3-00-00 39E0-0005-00 39E0-0007-00 3-035-09 3-0330-0 39A0-09-00 39A0-09-00-33-035-00 39-005-00 39-005-00 3-035-00 3-035-00 39-005-00 39-005-00 3-0-08 3-05-09 3-0075-00 3-0075-00 39-005-00 39-005-00 Quantity FOR TECHNICAL ASSISTANCE SEE YOUR LOCAL RETAILER OR CONTACT US AT: Phone : -877-7-78

5. PARTS LIST (RMC-KFA0TDGD-0 Model Only) KEY NO. 3 5 7 8 9 0 3 5 7 8 9 0 - - -3 - -5 - -7-8 -9-0 - - -3 3 5 5-5- 5-3 5-5-5 DESCRIPTION Fuel Tank Assembly Fuel Drain-Bolt Fuel Gauge Fuel Filter Assembly Fuel Cap Cord Bushing Power Cord Thermostat Shell Lower Clip Nut Bushing-Grommet(S) Bushing-Grommet(L) Air-Line Temperature Limit Assembly Flange-Screw Chamber Assembly Bracket Photocell Screw-BH Photocell Assembly Burner Head Assembly Bracket Burner Nozzle Washer-Nozzle Seal Spring-Nozzle Seal O-Ring Adaptor Nozzle Nipple Retaining Ring Bracket Spark Washer-Fiber Spark Plug Washer-Spring Bolt-Flange Fuel Line Motor and Pump Assembly Motor Capacitor Motor Support Nut-Hex Holder Capacitor PART NO. RMC-KFA0TDGD-0 5-0009-00 39-007-00 5-005-00 55-000-00 5-0003-00 37-003-00 3980-0087-00 38C0-005-00 3-0-0 39-005-00 33-08-00 33-00-00 33-0-00 33-000-00 53-0005-00 39-005-00 5-00-00 39-005-00 33-059-00 3-008-00 *SP-KFA007 5-003-00 3-05-00 *SP-KFA0 39-00-00 33-000-00 33-000-00 33-087-00 35-000-00 3-007-00 33-08-00 39-007-00 *SP-KFA0 3-0009-00 39-003-00 39-005-00 33-009-00 5-009-00 3970-000-00 380-03-00 3-058-00 33-003-00 33-05-00 Quantity 5

5. PARTS LIST (RMC-KFA0TDGD-0 Model Only) KEY NO. 5-5-7 5-8 5-9 5-0 5-5- 5-3 5-5-5 5-5-7 5-8 5-9 5-0 5-7 8 9 30 3 3 33 3 35 3 37 38 39 0 3 5 DESCRIPTION Pump Body Bolt-BH Special Rotor Blade Insert End Pump Cover Elbow Lint Filter Bolt Flange Output Filter End Filter Cover Ball Spring Adjusting Screw Bolt Flange Intake Filter Fan Assembly Bolt - Headless Hex Socket Pressure Gauge BTU Control Switch Main P.C.B Assembly Screw-THS Ignitor Side Cover-Right Power Switch Window Display Side Cover-Left Electric Outlet Assembly Outlet Cover Screw-Top Table Shell Upper Fan Guard Fan Guard Bushing PART NO. RMC-KFA0TDGD-0 35-0050-00 3-098-00 *SP-KFA0 See SP-KFA0 See SP-KFA0 353-0008-00 33-0093-00 *SP-KFA005 39-00-00 See SP-KFA005 3-007-00 *SP-KFA00 See SP-KFA00 See SP-KFA00 39-00-00 See SP-KFA005 39-005-00 5-0007-00 33-000-00 370-009-00 5-0070-00 5A-003-00 3-00-00 39E0-00-00 3-0330- 39A0-09-00 33-03-00 39-005-00 3-039-00 39D0-03-00 33-0-00 39-00-00 39-005-00 3-05-09 35-0078-00 335-000-00 39-005-00 Quantity 3 FOR TECHNICAL ASSISTANCE SEE YOUR LOCAL RETAILER OR CONTACT US AT: Phone : -877-7-78

5. PARTS LIST (WHEELS AND HANDLE) ) RMC-KFA50DGD/75TDGD MODELS KEY NO. DESCRIPTION PART NO. RMC-KFA50DGD RMC-KFA75TDGD Quantity Handle 33-0073-00 33-0073-00 Hardware Kit HW-KFA000 HW-KFA000 ) RMC-KFA5/70/0TDGD-0 MODELS KEY NO. 3 5 7 8 9 0 0-0- DESCRIPTION Snap Fit Front Handle Snap Fit Rear Handle Top Handle Support Bottom Leg And Wheel Support Right Bottom Leg And Wheel Support Left Snap Fit Front Leg Cord Wrap Threaded Axle Wheel Hardware Kit Cap Nut Bushing PART NO. RMC-KFA5TDGD-0 RMC-KFA70/0TDGD-0 355-008-00 355-009-00 355-0070-00 355-0077-00 355-007-00 355-0073-00 355-0077-00 355-0079-00 355-007-00 355-0078-00 355-007-00 355-0075-00 3-00-00 3-00-00 355-0088-00 355-0089-00 370-007-00 370-007-00 HW-KFA05 HW-KFA05 INCLUDED IN HARDWARE.KIT INCLUDED IN HARDWARE.KIT INCLUDED IN HARDWARE.KIT INCLUDED IN HARDWARE.KIT Quantity 3 5 7 9 8 0-0- 7