Energy Recovery Ventilators MCV CORE Series. Customer for Life: Power of Connections Johnson Controls, Inc Page 1

Similar documents
MiniCore Ventilator (500, 1000) Series Engineering Guide

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)

Residential Heat & Energy Recovery

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

RT-OA TM Rooftop Outdoor-Air (DOAS)

Energy Recovery with Cooling and Heating Model ERCH

TECHNICAL SPECIFICATIONS

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

White Paper. Executive Summary. Overview of Membrane Exchangers CLCH-PRB063A-EN. June 2017

Bill McCullough. Director ERV Products. Dallas, TX

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

P.O. Box 2758 Windsor, Nova Scotia, B0N 2T0 Ph Fax:

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

IT S ABOUT TIME FOR FRESH AIR.

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

************************************************************************************************************************

THE ULTIMATE ROOFTOP SOLUTION

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

************************************************************************************************************************

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

TR Series - The Ultimate ERV

HEAT RECOVERY VENTILATOR

Energy Recovery with Cooling and Heating

Limited Lifetime core warranty. 5-year warranty on balance of unit.

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

ENERGY RECOVERY VENTILATOR WITH OPTIONAL TEMPERING

ENERGY RECOVERY VENTILATOR

SEQUENCE OF OPERATIONS

Submittal Summary Page

IAQ VENTILATION SOLUTIONS

Cultivator & Hybrid Cultivator

Ventilation Solutions IAQ Canada

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Submittal Data Performance Data Electrical Data

Total Recovery for ALL Climates Models TR & TRC

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

62DA,DB,DC,DD,DE,DF07-38

SMART ERV Energy Recovery Ventilator. Build It Tight / Ventilate It Right!

Trane Performance Climate Changer Air Handlers. An air handler for every need.

Indoor Air Quality Product Brochure.

AHRI Guideline W (I-P) 2014 Guideline for Selecting, Sizing, & Specifying Packaged Air-to-Air Energy Recovery Ventilation Equipment

COMMERCIAL VENTILATION

Comfort Series. Energy Recovery Ventilator. Why Fresh Air Ventilation is Vital for Today s Energy-Efficient Homes

Energy Recovery Ventilators

Put the V back in HVAC

SECTION (15733) - DEDICATED OUTDOOR AIR UNITS

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

Scholar III Unit Ventilator

Indoor Air Quality Product Brochure.

SA Series Start up Report

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

IAQ VENTILATION SOLUTIONS

LIGHT COMMERCIAL Heat and Energy Recovery Ventilators

Glass Canopy Wall-Mount Hood

RoofPak Applied Rooftop Systems

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

WE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH.

Ventilation unit Zehnder ComfoAir 200

Energy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation

RT-OA TM Rooftop Outdoor-Air (DOAS)

Direct Gas-Fired Make-Up Air Models DG and DGX

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

BOOK 2 SPECIFICATIONS

Product Data HRV A10299

Gil Rossmiller. In the construction industry for over 30 years. ICC IRC Plumbing & Mechanical Code Development Committee

TABLE OF CONTENTS INTRODUCTION NOMENCLATURE AC P S J 035 C CO AR Q - 2 -

Product Data. ERVCCSVB, ERVCCSHB Energy Recovery Ventilators HRVCCSVB, HRVCCSHB Heat Recovery Ventilators

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Ventilation in Humid Climates: Data from Field Experiments

STEP INSIDE FOR A BREATH OF FRESH AIR. Designed to provide significant outdoor ventilation air to any space.

The ultimate fresh air solution.

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

Max Series 5 Speed Electronics Lifestyle MAX Digital Control included

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

COMMERCIAL HRV OPERATION AND INSTALLATION 69-COMHRV FD/DD, 650FD/DD, 700FD/DD, 1200FD/DD

Building Automation System (BAS) Design Criteria

INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR

THE RIGHT SPEC. RIGHT NOW.

Trane Performance Climate Changer Air Handlers. An air handler for every need.

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

AHU ENERGY RECOVERY VENTILATORS ERV DEDICATED OUTDOOR AIR SYSTEMS DOAS HEATING, COOLING & DEHUMIDIFICATION AHU

Benefits Offered by Passive Dehumidification Wheel Speed Control

Supplying Clean Air to Industry

Q-TEC QC-Series Chilled Water Air Conditioner

48PGD/E/F/L/M/N PG20-28

Outside Air Requirements... SOLVED!

************************************************************************************************************************

APPLICATION, INSTALLATION, AND MAINTENANCE MANUAL CA2XRT, CA3XRT, CA4XRT

Transcription:

Energy Recovery Ventilators MCV CORE Series Page 1

Introducing enervent MCV Static Core Series New Static CORE ERV series 300-1,200 CFM (Indoor Only) CORE differentiation Unique & proprietary heat exchanger Complementary line to newly expanded Mini-Vent series Page 2

Introducing enervent MCV Static CORE Series Page 3

Introducing enervent MCV Static Core Series Approx. Weight (Lbs) Airflow Range (CFM) Model A B C MCV500 42.3 50.9 15.5 200 300-600 MCV1000 42.3 50.9 20.6 235 600-1,200 Page 4

enervent MCV Differentiation Ruskin enervent Competitor 1 Competitor 2 CORE Substrate Polymer Membrane Cellulose Cellulose Washable Yes No No Freeze Tolerant Yes No No ASTM F1671 Viral Penetration Test 0 N/A N/A ISO 846 Test A & C Mold & Bacteria Resistance 0 N/A N/A EATR (Based on AHRI 1060) 0.50% 1% 2.98% Pressure Drop (in. w.g.) @ 100% Rated CFM 0.35 0.65 0.65 Total Effectiveness (Heating / Cooling) @ 100% Rated CFM 62% / 55% 64% / 53% 64% / 53% The Ruskin MCV CORE is uniquely different & superior to the competition Page 5

enervent MCV CORE Differentiation Proprietary Polymer Membrane Water Washable (No Cellulose) Freeze Tolerate (No Cellulose) Lower Frosting Temp & Shorter Defrost Time Avoid Virus Transfer (ASTM F-1671-0 Penetration) Mold & Bacteria Resistant (ISO 846 Rating 0) Crossover EATR < 0.5% (Actual Results 0.1%) Lower Pressure Drop (0.35 in w.g. @ 100% Rated CFM) Sturdy Aluminum Frame Page 6

enervent MCV CORE Differentiation Features Advantages Benefits Proprietary Polymer membrane Paperless (No Cellulose) Aluminum Spacers Installation Flexibility Water Washable Freeze Tolerant Resistant to Mold & Bacteria Improved Humidity & Moisture Control Field-Configurable Supply and Exhaust Connections Improved Reliability & Longevity Low Maintenance Faster Payback Simple & Easy Installation & Various Configurations Low Pressure Drop CORE Less Resistance to Airflow Energy Savings EC Motor Option JCI Metasys Control Option High Efficiency with Variable Speed Capabilities Seamless Integration into existing Building Automation Systems (BAS) & BACnet Integration Energy Savings Easy Set-Up, Installation, Commissioning & Unit Connectivity / Control Page 7

enervent MCV CORE How It Works SUMMER Cooling Season WINTER Heating Season Exhaust to Outside Supply to Inside Exhaust to Outside Supply to Inside Supply from Outside Exhaust from Inside Supply from Outside Exhaust from Inside Page 8

enervent Patented Polymer Membrane Advantage Patented Polymer Membrane allows sensible and latent energy to transfer while completely blocking contaminants such as Odors, VOC s, CO2 and Viruses. Page 9

enervent Patented Polymer Membrane Advantage ASTM F-1671 tested for no virus cross-over (Penetration 0) AATCC & ISO 846 tested for no mold or bacteria growth (Rating 0) Freeze tolerant tested to (40) freeze thaw cycles (-20 C to +20 C) while maintaining energy recovery and 0.5% EATR rating. UL 723 compliant with a flame spread index < 25 and smoke index < 5. Page 10

enervent MCV CORE Performance Rated Flow Rated Flow * CORE operating performance @ 100% Rated CFM Page 11

enervent MCV Mounting Configurations HORIZONTAL SIDE VERTICAL Page 12

enervent MCV Options / Accessories JCI Metasys Controls - BACnet MS/TP JCI MAP Enabling URL / WiFi Connectivity MERV 13-15 Filters EC Motors Backdraft & Motorized Isolation Dampers Page 13

Page 14