INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

Similar documents
Heat or Energy Recovery Ventilation System

Limited Lifetime core warranty. 5-year warranty on balance of unit.

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

VENTILATORS VH30100 COMPACT HEAT RECOVERY VENTILATOR VE30100 COMPACT ENERGY RECOVERY VENTILATOR. Installation and Operation Manual.

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Put the V back in HVAC

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

SAFETY AND INSTALLATION MANUAL MODEL 8100

INDOOR AIR QUALITY KITS AND ACCESSORIES /12 Supersedes 05/12

SER Series. fantech. Installation Manual. Energy Recovery Ventilators. ser 1504 ser 1504n ser 2004 ser 2004n ser 3204d ser 3204n

Light commercial models

INDOOR AIR QUALITY KITS AND ACCESSORIES /2014. Supersedes 06/2014

HOME OWNERS GUIDE ERV MODEL PE 7.15 PE SS Product of Imperial Air Technologies

NU800, NU1200 & NU1600

SER Series. Installation Manual. Energy Recovery Ventilators SER 1504 SER 2004 SER 3204D

Installation Guide. MAX Series. 69-MAX-Install Setting a new standard for energy efficient, clean air homes

TR Series - The Ultimate ERV

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704

INSTALLATION AND OPERATION INSTRUCTIONS

Indoor Air Quality Product Brochure.

SER150. Installation Manual. Energy Recovery Ventilators

Energy Recovery Ventilators

HR150, 200; ER150, 200 Perfect Window Fresh Air Ventilation Systems

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

IMPORTANT WARNINGS IMPORTANT SAFETY INSTRUCTIONS

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

SER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

OPERATIONS & MAINTENANCE MANUAL RESIDENTIAL HEAT & ENERGY RECOVERY VENTILATORS TO BE COMPLETED BY CONTRACTOR AFTER INSTALLATION

10-year industry best core warranty. 5-year warranty on balance of unit.

Indoor Air Quality Product Brochure.

Heat Recovery Ventilators models:

SHR & VHR Models. SHR & VHR Series. Installation Manual. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

PW 150 / PW 100. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT INSTALLATION, OPERATION AND MAINTENANCE MANUAL 1

MODELS LT15 & LT20 INSTALLATION INSTRUCTION FOR HEAT RECOVERY VENTILATOR (HRV)

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION GUIDE RESIDENTIAL USE ONLY. Greentek Models SS 3.80 FSD HRV (Item No ) SS 3.80 FSD ERV (Item No )

Summeraire Manufacturing Peterborough, Ontario, Canada, K9J 6X6

Residential Heat & Energy Recovery

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY AND SAVE R3

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL HEAT & ENERGY RECOVERY VENTILATORS FOR MODELS: H/E80 H/E130

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

VHR SERIES VHR 704. Installation Manual. Heat Recovery Ventilator INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

INSTALLER AND USER MANUAL VENTILATION SYSTEM

Ventilation, Makeup and Combustion Air Calculations Submittal Form New Dwellings

ClalrlTech INNOVATIONS. ClairiTech. 120 Hybrid. Installation and Operations Manual Model: H-120 Rev: 1.4

INSTALLATION AND OPERATION MANUAL Model BR70/BR130

HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.

City of Chanhassen. Site address. Ventilation Quantity (Determine quantity by using Table R or Equation R )

INSTALLATION GUIDE VB0180 VB0148

Site address. Ventilation Quantity (Determine quantity by using Table N or Equation 11-1) Continuous ventilation

INSTALLATION AND OPERATION MANUAL MODEL TR70\TR130\TR200\TR300 TOTAL RECOVERY FOR ALL CLIMATES (TR)

Installation Instructions

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Address of your installer

FOR MODELS: VENMAR 1.3, 1.8 & 2.6 HE VENMAR 3055 & 5585 COMPACT vänee 1000, 2000 & 3000 HE

HR150B, HR200B Perfect Window Fresh Air Ventilation Systems

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V

SMART ERV Energy Recovery Ventilator. Build It Tight / Ventilate It Right!

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

USER GUIDE HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+, MODEL ERV 90H-V ECM PLEASE READ AND SAVE THESE INSTRUCTIONS

KHP 6000 KHP MODEL FOR LIGHT COMMERCIAL

Tech to Tech May 07 HRV s & ERV s

Ventilation Solutions IAQ Canada

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

INSTALLATION AND OPERATION MANUAL 90-Series

HEAT RECOVERY VENTILATORS MODELS AVS E15 ECM HRV, AVS E15 HRV, AVS E10 HRV AND ENERGY RECOVERY VENTILATOR MODEL AVS E15 ECM ERV

Ventilation Solutions IAQ Canada

Installation Instructions

HRV / ERV INSTALLATION AND OPERATING INSTRUCTIONS

Why ventilate? Dilute contaminants Control or aggravate humidity Comfort or lack of cooling Odors Provide oxygen

VIGÖR HRV PLUS AND VIGÖR ERV

P.O. Box 2758 Windsor, Nova Scotia, B0N 2T0 Phone: Fax:

Heat Recovery Energy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

PHRV(R) Series. Heat Recovery Ventilator PHRV 140 PHRV 150 PHRV 200 PHRVR 155 PHRVR 160 PHRVR 205 PHRVR 210 PHRVR 305

Installation Instructions

Installation Instructions

IAQ VENTILATION SOLUTIONS

IAQ VENTILATION SOLUTIONS

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

Model 8120 and 8126 Safety & Installation Instructions

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

INSTALLER MANUAL RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

Deluxe Series RHRV-D100P RERV-D100. model: RHRV-D100A. HRV / ERV INSTALLATION AND OPERATING INSTRUCTIONS.

INSTALLATION GUIDE FOR VENMAR AVS UNIT CONSTRUCTO 1.0 HRV AND CONSTRUCTO 1.0 ERV

HEAT RECOVERY VENTILATORS AND ENERGY RECOVERY VENTILATORS CONSTRUCTO 1.0 MODELS: Model no.: (HRV with ports on top)

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES

Ventilation BCBC 9.32 & Richard Kadulski Architect

Transcription:

INSTALLATION GUIDE Horizontal series HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

INSTALLATION GUIDE Peace of Mind All GeneralAire products are backed by the best limited warranty in the industry, for your peace of mind. You benefit from a lifetime warranty on the core, a 10-year warranty (5 years + 5 years prorated) on our ventilation motors, a 5-year warranty on the enthalpic core, and a 5-year warranty on all other components. So you can breathe easy. About Us GeneralAire offers you a complete range of products designed to improve indoor air quality, and that provides a wide selection of accessories to facilitate installation. Our vision To offer a complete range of GeneralAire products that satisfy environmental concerns. Whether your needs involve ventilation, purification, humidification or filtration, GeneralAire has the customized solution for you, with its range of quality products backed by the best warranty in the industry. Installation INFORMATION FOR INSTALLERS 1. Ventilation needs 2. Types of installation 3. GeneralAire HRV/ERV systems 4. Finding a suitable installation area for the HRV or ERV 5. Installation of the HRV/ERV 6. Rigid duct 7. Insulated flex from unit to outside wall 8. Condensation drain line 9. Devoted electric receptacle 10. Outside fresh air and exhaust air hoods 11. Fresh air and exhaust air grilles 12. Benefits of the Duotrol TM system 13. Balancing the unit PAGE 3 3 6 6 7 7 8 9 10 11 12 13 14 Functions and Controls INFORMATION FOR HOME OWNERS AND INSTALLERS 14. Controls and wiring Technical Information INFORMATION FOR HOME OWNERS AND INSTALLERS 15. Troubleshooting 16. Wiring diagram 17. Maintenance 18. Specification and technical information PAGE 15 PAGE 19 20 21 22 2

1.Ventilation Needs Determine your ventilation needs installation How much fresh air do I need? Good air quality is based in part on the capacity of the home s ventilation system. Usually, the HRV s or ERVs capacity is measured in CFM (cubic feet per minute) or L/s (Liters per seconds) of fresh air being distributed in the living space. The room count calculation or the air change per hour method shows you how to determine your ventilation needs. Independent system installation This application uses a devoted duct system for the supply and the exhausting of stale air accumulated in the home. It is recommended to install fresh air grilles in all bedrooms and living areas. Exhaust the stale air from the bathroom, kitchen and laundry room. A. Room count calculation LIVING SPACE Master Bedroom With Basement Without Basement Single Bedroom Living Room Dinning Room Family Room Recreation Room Other Kitchen Bathroom Laundry Room Utility Room B. Air change per hour method TOTAL cu ft x 0.35 per hr = total Take total and divide by 60 to get CFM Example: 2. Types of Installation Independent System Number of Rooms CFM (L/s) CFM Required x 20 cfm (10 L/s)= x 20 cfm (10 L/s)= TOTAL ventilation requirement (add last column)= x 10 cfm (5 L/s)= x 10 cfm (5 L/s)= x 10 cfm (5 L/s)= x 10 cfm (5 L/s)= x 10 cfm (5 L/s)= x 10 cfm (5 L/s)= x 10 cfm (5 L/s)= x 10 cfm (5 L/s)= x 10 cfm (5 L/s)= 25' x 40' house with basement 1,000 sq. ft. x 8' high x 2 (1st floor + basement) = 16,000 cu. ft. 16,000 cu. ft. x 0.35 ACH = 5,600 cu. ft. 5,600 cu. ft./60 minutes = 93 CFM 93 CFM is your ventilation need 1 CFM = 0.47189 L/s 1 L/s = 3.6 m 3 /hr 3

INSTALLATION GUIDE 2. Types of Installation (continued) Exhaust at the source and supply in the return installation There are different practices used to combine HRV or ERV to a forced air system. Exhaust at the source 3' This application uses a devoted duct system for the exhausting of stale air accumulated in the home. The fresh air is dumped into the return air duct and is distributed thru the home by the existing supply air ductwork of the forced air system. Make sure when using this application that your fresh air duct connection to the forced air system return air duct is at least 3' from the forced air system. You should check with your local code or the forced air system s manufacturer. 18" 6' From Bathroom or Kitchen HRV/ERV To living space Forced Air System *For minimum distance between return and forced air system, check with your local building codes and forced air system manufacturer. Indirect Connection - Breathing Tee Indirect Connection - Return Air Grille A Breathing Tee is a ventilation air supply duct with an open tee located before the connection to the return air duct. It allows the HRV to function without supply air flow rates being affected by the forced air system s fan speed. Leaving a gap in the ventilation air supply duct in place of the breather tee is acceptable but not recommended. With the return air grille approach, HRV or ERV ventilation supply air is dumped near a grille (between 4" and 12") in the return air duct upstream of the recirculation fan. 4" to 12" maximum 4 *See your local code before making an installation.

2. Types of installation (continued) Exhaust and supply in the return installation Exhaust and supply in the return 6 3 When using this application make sure that there is at least 6' between the fresh air and exhaust air connections of the HRV or ERV in the return air duct. Supply air from HRV or ERV must be at least 3' from the forced air system. Can be different from a region to an other. You should check with your local code or the forced air system s manufacturer. Note Fresh air must always be down-stream from the exhaust air in the return air duct of the forced air system. Exhaust from the return and supply in supply installation When using this application make sure that the Supply air from HRV or ERV is at least 3' from the forced air system. Can be different from a region to an other. You should check with your local code or the forced air system s manufacturer. 6 18 HRV / ERV Simplified Connection Exhaust from return and supply in supply 6 To living space Forced Air System FOR MINIMUM DISTANCE BETWEEN RETURN AND FORCED AIR SYSTEM Check with your local building codes and force air system manufacturer. 18 HRV / ERV Forced Air System 5

INSTALLATION GUIDE 3. GeneralAire HRV/ERV systems Installation Kit Included in the installation kit: 4 Collars 2 Flexible Vinyl Ducts 1 Condensation Drain Line 1 Drain Adapter with Nut 4 Tie Wraps (30 ) 16 screws (#10 x 5/8") 4 screws (#10 x 1") 4 Washers TIPS Removing the core unit will facilitate your job. Figure 3.1 Pull out the inserts first then use the straps to lift the unit out of the box. Figure 3.2 Installation kit is shipped inside the unit. Figure 3.3 Installation kit. 4. Finding a suitable installation area for HRV or ERV The HRV or ERV units should be installed in a mechanical room or as close to an outside wall as possible. This would assure a short run of insulated flexible duct. The HRV or ERV unit must always be installed in an area where the air is tempered to avoid freezing of the condensate line. The contractor should install the unit in area that is very accessible to allow the homeowner easy access for maintenance. It is very important to install an electric receptacle (115v) near the HRV or ERV, a separate circuit breaker is also recommended. You should have access to a condensate drain near the HRV or ERV to avoid the use of condensate pump. 6

5. Installation of the HRV/ERV The SPM TM system is supplied with the HRV or ERV to allow one person mounting of unit. TM SPM attachment system The entire line of GeneralAire HRV/ERV products is designed for installation by a single person. Single Person Mounting TM will enable you to save time and effort by offering you a variable attachment system and maximizing your basement space. figure 5.1 Place HRV/ERV on a stepladder. TIPS If unit is not level, improper drainage will occur and could lead to moisture and leakage problems. TIPS It is recommended to use approximately 16" of flexible duct (supplied in kit) between the HRV or ERV and your rigid duct (see figure 6.1). The flex duct is mounted the same way to the HRV or ERV as the insulated flex close on step 6 (see figure 6.2). figure 5.2 Attach your four straps to the floor joist making sure that you attach thru the washers and the grommets. 6. Rigid duct figure 5.3 Pull on the middle strap and gently push upward on the unit. Then repeat procedure on other side. figure 5.4 When completing the procedure make sure that the HRV or ERV is leveled. figure 6.1 Mount flex to HRV/ERV. figure 6.2 Mount flex to rigid duct. 7

INSTALLATION GUIDE 7. Insulated Flex from Unit to Outside Wall. ISF TM collar system (Patent Pending Technologies) Quick and simple to install thanks to our revolutionary Insert Slide and Fix TM collar system. The ISF TM collar system enables you to manipulate duct within your reach and then insert the collar to the HRV/ERV by sliding it in place, for a better and quicker installation. TIPS To ensure a better installation and to avoid an undesired bend in the duct, align the duct with the collar before securing over the four hooks. figure 7.1 ISF TM collar system - removable part. The installer can now beneficiate from the ISF TM collar system for its flex duct installation to the unit. Take four collars out of the unit. Insert the flex over the interior flange of the collar. Make sure that flex is pushed all the way, so the four tabs on the collar hooks on to the flex. Seal with tie wrap (4 tie wraps supplied with unit). Pull insulation over the interior flange. Pull vapor barrier over outer flange on the collar and seal with duct tape. figure 7.2 Insert vinyl duct over the hooks and seal with a 30" tie wrap. figure 7.3 Insert insulation inside the collar. figure 7.4 Finish by taping the duct on the collar. Once insulated flex is attached to the collar, slide collar in keeper section, fixed collar to the unit with four screws supplied in installation kit. Insert the threaded drain adapter thru the bottom of the HRV or ERV and hand tighten the plastic nut supplied with the drain kit. 8 figure 7.5 Slide collar on the unit. figure 7.6 Fix and secure with two screws supplied.

8. Condensation Drain Line Sloped Drain Pan drainage system GeneralAire HRV/ERV units are equipped with an easyaccess sloped drain pan. Excess condensation that might accumulate inside the unit migrate to the centre of the drain pan to be evacuated. figure 8.1 Hand screw the drain adapter Insert the threaded drain adapter thru the bottom of the HRV or ERV and hand tighten the plastic nut supplied with the drain kit. Install the condensate line (10 feet included in drain kit). Insert condensate tubing by pushing clear plastic line over drain adapter. Make condensate trap by looping the clear plastic tubing. This procedure is to avoid foul odor to enter the HRV or ERV. figure 8.2 Insert condensate line. figure 8.3 Make a loop in condensate line. figure 8.4 Use a condensate pump if you don t have access to the floor drain. 9

INSTALLATION GUIDE 9. Devoted Electric Receptacle Insert the power cord on top of the unit. Press firmly to make sure the power cord is secure. figure 9.1 HRV/ERV s Power Cord It is recommended that the HRV or ERV have a devoted receptacle with 115v. It is not recommended to connect unit with an extension cord. If no receptacle is available please call an electrical contractor and have one installed. figure 9.2 Electric Wall Outlet 10

10. Outside Fresh Air and Exhaust Air Hoods TIPS To make your installation easier use our double collar to install your flex pipe with the outside hoods (figure 12.2). 72" TIPS We manufacture a wide selection of: Insulated flexpipe Hoods 18" TIPS Extend the sheet metal sleeve 1.5" inside the home. Attach GeneralAire specialty ISF TM collar to sheet metal sleeve. figure 10.1 Locating outside hoods. figure 10.2 Insert vinyl duct over the hooks. Fix the collar on the floor joist. figure 10.3 Insert insulation inside the collar and finish by taping the vapor barrier on the collar. figure 10.4 Install outside hoods. 11

INSTALLATION GUIDE 11. Fresh Air and Exhaust Air Grilles TIPS Note: It is not recommended to exhaust your clothes dryer, your kitchen exhaust hood or your central vacuum cleaner thru your ventilation system. Save Time and Space... with GeneralAire s Stack Head Elbow available to fit your needs. Ask your local distributor for more information on our full range of accessories. We manufacture a wide selection of: Duct Stack Head Elbow Grilles figure 11.1 Grille. It is recommended to install fresh air grilles in all bedrooms and living areas. The exhaust air grilles should be located in the bathrooms, kitchen, laundry room and storage room. Grilles are usually installed 12" from the ceiling. GeneralAire grilles are recommended for quiet air diffusion (4, 5, 6 and 8 inches are offered). The grilles combined with our GeneralAire 4" space saving grille adapters (stack head elbow) makes for easy and time saving installation. figure 11.2 Stack head elbow. figure 11.3 Insert grille. It is recommended to exhaust the stale air from the bathroom, kitchen, laundry room and storage room. These areas have been found to be the most pollutant areas in a home. For the kitchen we recommend the use of GeneralAire s grease filter grilles. 12

12. Benefits of the Duotrol TM System DuoTrol TM balancing system (Patent Pending Technologies) Silent and economical... By reducing motor speed to balance the unit, you avoid the noise that would be produced by balancing dampers. In addition, with this technology the unit will consume less energy. Mode selector Intermittent Continuous Off figure 12.1 Duotrol TM System GeneralAire s Duotrol TM balancing system (patent pending) is state of the art technology simplified for quick and easy installation for the contractor s peace of mind. The Duotrol TM serves two purposes. Acts as a mode selector Intermittent: When the selector switch is in the intermittent position the HRV or ERV will only run when there is a call for ventilation by any control. At that time the unit will run on high speed until the condition is satisfied. Continuous: When the selector switch is in the continuous position the HRV or ERV will run continuously on low speed except when there is a call for override by any control. Off: When the selector switch is in the off position the HRV or ERV will not come on even if there s a call for ventilation by any control. Balancing control Intermittent Continuous Off Acts as a balancing control (see instructions) The Duotrol TM lets contractor set speed of the motors for balancing purposes (Exhaust air, Fresh air and Both motors). INTER.: Selects the exhaust air motor CONT.: Selects both exhaust and fresh air motors OFF: Selects the fresh air motor + Button: Increase the speed of the selected motor. Increase Speed - Button: Decrease the speed of the selected motor. Decrease Speed 13

INSTALLATION GUIDE 13. Balancing the unit TIPS As mentioned in the section, the Duotrol TM System has two different purposes. 1. Mode Selector 2. Balancing Mode The light indicator shows you in which mode the Duotrol TM System is in. GREEN LIGHT Mode Selector YELLOW LIGHT Balancing Mode figure 13.1 Duotrol TM System 14 figure 15.6 Selector Switch Using the Selector Switch When on Balancing Mode, the Selector Switch allows you to choose the motor you want to set. Closed Duotrol Cover 1. INTER (Exhaust Motor) 2. CONT (Both Motors) 3. OFF (Supply Motor) or Open Duotrol Cover 1. UP (Exhaust Motor) 2. MIDDLE (Both Motors) 3. DOWN (Supply Motor) figure 13.2 Magnehelic Gauge with Air Flow Grid figure 13.3 Magnehelic Gauge with Air Flow Grid figure 13.4 Inserting Air flow grid in duct figure 13.5 Seal Air flow grid in duct with duct tape. Step 1: Press the (+) and ( ) buttons simultaneously until you see the yellow light. Once the indicator light turns yellow you are in balancing mode. Step 2: When in balancing mode the selector switch becomes the motor selector switch. INTER (Right Motor), CONT (Both Motors) and OFF (Left Motor) Step 3: Once the total cfm needed is determined, you can start balancing the HRV/ERV. Set your fresh air supply by selecting the OFF position on the Duotrol TM. Install your magnehelic gauge and air flow grid in the fresh air duct. Step 4: Press the ( ) button to decrease the cfm or press the (+) button to increase the CFM. Step 5: Then perform the same operation on the stale air side by selecting the INTER position on the Duotrol TM. Step 6: The CONT position will allow you to adjust the cfm on both motors proportionately (if necessary). Step 7: Once this is completed, you have set the high speed on your HRV/ERV. To lock balancing mode you must press (+) and ( ) buttons simultaneously and release. The indicator light will turn green to indicate normal operation mode. Step 8: Once high speed is set and locked, switch to continuous on the Duotrol TM. By using (+) and (-) buttons set low speed on the HRV/ERV. Step 9: Select the mode of operation. (Intermittent, Recirculation or Continuous Ventilation)

14. Controls and Wiring Range of controls The entire range of GreenThinker TM model controls is offered with features making your ventilation system simple, easy to operate and backed by a 5-year limited warranty. RD-I model TM DEHUMIDISTAT Features Dehumidistat to select the humidity level GeneralAire s RD-I model TM allows the homeowner control of the indoor humidity level. RD-I model TM is compatible with the P, F and SHM models TM. The RD-I model TM is a two wires connection. On the Duotrol TM System and the RD-I model TM use R and G terminal connections on the lower right hand side of the control board. figure 14.1 RD-I model TM figure 14.2 Duotrol TM RD-II model TM DEHUMIDISTAT Features Dehumidistat to select the humidity level Speed Control (Off, Normal and Reduced) Light On Override GeneralAire s RD-II model TM allows the homeowner control of the indoor humidity level by selecting the humidity percentage and fan range (off, normal and reduced). RANGE OFF : NORMAL : REDUCED : DEMAND Light indicator This function allows the HRV or ERV to be shut off by the remote dehumidistat. This function allows the HRV or ERV to operate on balanced low speed. This function allows the HRV or ERV to operate on lower speed, continuous and override. Shows homeowner when HRV or ERV is on override by switching on a display light on the remote dehumidistat or any other control. figure 14.3 RD-II model TM figure 14.4 Duotrol TM 15

INSTALLATION GUIDE 14. Controls and Wiring (continued) RD-IIImodel TM DEHUMIDISTAT PROFESSIONAL Features Dehumidistat to select the humidity level Speed Control (Off, Normal and Reduced) Mode Control (Intermittent and Continuous Ventilation) Light On Override GeneralAire s RD-III model TM allows the homeowner control of the indoor humidity level by offering three selections of operation. The controller allows the homeowner to select humidity percentage, fan speed and operation mode. MODE Intermittent: Recirculation: Continuous: Allows the homeowner to select intermittent or continuous on the Professional model and recalculation on the Deluxe model. Allows HRV or ERV to run only when there is a call for ventilation. Allows HRV or ERV to run continuously on low speed. * See RD-1 and RD-2 for other functions figure 14.5 RD-III model TM figure 14.6 Duotrol TM The above controller have four wires connection. On the Duotrol TM System and RD-III model TM use R, G, B and W terminal connections on the lower right hand side of the control board. GeneralAire s RD-IV model TM allows the homeowner control of the indoor humidity level by offering four selections of operation. The controller allows the homeowner to select the humidity percentage, fan speed, operation mode and cycles per hour. 16

14. Controls and Wiring (continued) RD-IVmodel TM DEHUMIDISTAT PROFESSIONAL Features Dehumidistat to select the humidity level Speed Control (Off, Normal and Reduced) Mode Control (Intermittent and Continuous Ventilation) Cycles per hour (0/0, 20/40 and 30/30) Light On Override Maintenance Light Reminder GeneralAire s RD-IV model TM allows the homeowner control of the indoor humidity level by offering four selections of operation. The controller allows the homeowner to select the humidity percentage, fan speed, operation mode and cycles per hour. CYCLES 0 20/40 30/30 MAINTENANCE Light indicator: Allows the homeowner to select cycles per hour Normal operation mode 20 minutes on high speed and 40 minutes on previously set mode of operation 30 minutes on high speed and 30 minutes on previously set mode of operation Shows homeowner when HRV or ERV needs to be maintain. * See RD-1 and RD-2 for other functions figure 14.7 RD-4P and RD-4D model TM figure 14.8 Duotrol TM The above controller have four wires connection. On the Duotrol TM System and RD-IV model TM use R, G, B and W terminal connections on the lower right hand side of the control board. 17

INSTALLATION GUIDE 14. Controls and Wiring (continued) T-Vmodel TM PUSH-BUTTON TIMER Feature 20/40/60 minutes exchange GeneralAire s Vmodel TM allows the homeowner controls of the indoor humidity level in rooms were more humidity is produced (Ex. bathroom and kitchen). The Vmodel TM allows the homeowner to override the RD model TM to high speed for a determined length of time (20min, 40min and 60min). figure 14.9 Vmodel TM figure 14.10 Duotrol TM The Vmodel TM is a three wires connection. On the low voltage control board use R, G and B terminal connection on the top right hand corner of the board. To operate: Press the PUSH button once, the light indicator will blink one time. The unit will operate at high speed for 20 minutes. Press the indicator light until it blinks twice, the unit will operate at high speed for 40 minutes. Press the indicator light until it blinks 3 times, the unit will operate at high speed for 60 minutes. (Pressing the button gives you the first blink.) 18

15. Troubleshooting Peace of Mind Ensure your comfort in the years to come by using GeneralAire systems and accessories to install any ventilation, humidification, purification or filtration product. Need help? You benefit from certified customer service ready to guide you in the installation or operation of your GeneralAire system. Call: 1-248-476-5100 PROBLEMS HRV or ERV not running Air is too dry SOLUTIONS Verify breaker in electrical box Verify that dehumidistat or switch on HRV or ERV are activated to supply power to unit. Unplug HRV or ERV verify if controller is wired correctly to the connection box on the side of the unit. Verify low voltage box (Duotrol TM )on the unit Increase humidity level on dehumidistat. Switch ventilation mode from continuous to intermittent Install a GeneralAire humidifier Air too humid Reduce the humidity level on the controller. Verify if dryer is venting in basement. Verify if heating wood is stored in basement. Wait for outside temperature to change. Ex. Summer can be extremely humid. Verify balancing of the HRV or ERV. 19

INSTALLATION GUIDE 16. Wiring Diagram Standard Forced Air Interlocking Wiring Standard Forced Air Interlock Wiring A relay is normally used when tying a ventilation system onto forced air distribution system. Our Duotrol System is equipped with an internal relay that will activate the forced air system ventilator when there is a demand from the HRV/ERV. The Duotrol System will activate the INTERLOCK relay during the following modes: Continuous, Override, Recirculation and Defrost. See wiring diagram. Alternate Forced Air Interlocking Wiring Some forced air system thermostat will activate the cooling system when tied using the Standard forced air interlocking wiring. If you have identify this type of thermostat you must proceed with the Alternate forced air wiring. Alternate Forced Air Interlock Wiring Locating the Wiring Diagram Wiring diagram for the entire line of professional and furnace models are placed on the back of each exhaust motor bracket. 20 *Before tying the HRV/ERV to a forced air system,always refer to system s manual or manufacturer.

17. Maintenance FMA TM maintenance system In order to improve air quality and offer the best possible air quality in your home, GeneralAire has developed one of the first maintenance service systems in the industry. The Filter Maintenance Adviser TM will remind you by e-mail when the filter of your HRV/ERV system must be replaced, to maximize its performance and efficiency. For more information call: 1-248-476-5100 When should I Service my HRV/ERV? service and accessories HEAT RECOVERY CORE UNIT Once a year or as needed, vacuum the four surfaces, let soak in warm water for three hours, then spray rinse and let dry. FILTERS Four times a year or as needed, vacuum the filters. Replace filters once a year. INSIDE THE UNIT Once a year or as needed, clean the interior of the unit (walls and drain pan) with a mild and non abrasive soap. It is recommended to use products that are environmentally-friendly. ENERGY RECOVERY CORE UNIT Once a year or as needed, vacuum the four surfaces. Note IMPORTANT : ALWAYS UNPLUG HRV OR ERV DURING SERVICING figure 17.1 Slide Out the Filters figure 17.3 Slide out the Energy Core figure 17.2 Vacuum the Filters figure 17.4 Wash the Walls of the Unit 21

INSTALLATION GUIDE 18. Specification and Technical Information PROFESSIONAL,DELUXE AND FURNACE MODELS Easy Access Door removable top hinge door SPECIFICATIONS Size Heat exchanger (L x H x W) CFM Type of heat exchanger Exchange surface Power consumption Defrost type Certification 8160 8220 23 7/8 " x 21 1/2 " x 11 3/8 " 23 7/8 " x 21 1/2 " x 16 1/2 " 12" x 12" x 10" 12" x 12" x 15" 30 to 160 50 to 220 cross-flow cross-flow 104 ft 2 150 ft 2 130 W 150 W Exhaust Exhaust HVI, C CSA US HVI, C CSA US 8160 11 3 / 8" 8260 16 1 / 2" 3160 11 3 / 8" 3220 16 1 / 2" 23 7 / 8" 21 1 / 2" SPECIFICATIONS Size Heat exchanger (L x H x W) CFM Type of heat exchanger Exchange surface Power consumption Defrost type Certification 3160 3220 23 7/8 " x 21 1/2 " x 11 3/8 " 23 7/8 " x 21 1/2 " x 16 1/2 " 12" x 12" x 10" 12" x 12" x 15" 30 to 160 50 to 220 cross-flow cross-flow 104 ft 2 150 ft 2 130 W 150 W Exhaust Exhaust CCSA US C CSA US Note All GeneralAire products are backed by the best limited warranty on the market. GeneralAire reserves the right to modify a product, without prior notice, whether in design, colour or specifications, in order to offer at all times a quality product that is highly competitive. Please consult local authorities to find out whether the installation of electrical products requires the services of a certified technician or electrician. Certified Products and Proud Member of These Associations * 22