SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

Similar documents
FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

SINGLE-ROOM ENERGY RECOVERY VENTILATORS

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

KOMFORT EC DB Suspended heat recovery air handling units

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

AIR HANDLING UNIT WITH HEAT RECOVERY

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

SINGLE-ROOM VENTILATION. for schools and public spaces

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Series VENTS VUT R WH ЕС

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Description of components and operating logic of the unit MICRA Ventilation system arrangement example based on the unit MICRA 60...

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Installation manual Mini Comfort 50 S/L 07/ V EN

COMMERCIAL VENTILATION

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

HEAT RECOVERY AIR HANDLING UNITS

Outside Air Requirements... SOLVED!

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

HEAT RECOVERY VENTILATOR

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

Destratification Fan Units DRF-VK & DRF-VKM & DRF-OV

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

USER'S MANUAL. Micra 150 HEAT RECOVERY UNIT

Caution: The fans must not be used in bath or shower enclosures.

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

HEX390 Heat Exchanger

ENERGY SAVING VENTILATION GEO VENTS GEOTHERMAL SYSTEMS

Ventilation Unit Zehnder ComfoAir 350

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

VERSO Air Handling Units

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

USER S MANUAL. VKP Series INLINE FAN

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

Domestic & Commercial Fans

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

VERSO Air Handling Units

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

VENTS КАМ. Series CHIMNEY CENTRIFUGAL FANS

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

WiFi. Roomie One WiFi Roomie Dual WiFi. Assembly and Operation Instructions. Heat recovery single-room reversible ventilation unit EN

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

AIR HANDLING UNITS ver B

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

Axial intelligent fan USER S MANUAL

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

AIR HANDLING UNITS MANDÍK

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

VENTILATION WITH HEAT RECOVERY

CENTRIFUGAL CEILING EXTRACT FAN

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

Overview and Specifications

The Sentinel Kinetic Horizontal Range

TECHNICAL SPECIFICATIONS

Controlled mechanical ventilation GB 03

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

vortice.com RESIDENTIAL VENTILATION VORT HRW 20 MONO RANGE Decentralized heat recovery units NEW

Mini fans MiniVent M1/100

Air handling units with an integrated heat pump and rotary heat exchanger

Tech to Tech May 07 HRV s & ERV s

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Residential Heat & Energy Recovery

Small Room Heat Recovery Ventilation

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

READ AND SAVE THESE INSTRUCTIONS

Kair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery

Ventilation unit Zehnder ComfoAir 200

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Transcription:

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

SINGLE-ROOM HEAT RECOVERY UNITS FRESHBOX 60 Use q Heat recovery single-room air handling unit for supply and exhaust ventilation. q Efficient energy-saving single-room ventilation of flats, houses, cottages, social and commercial premises. q Ideal solution for simple and efficient ventilation of new or refurbished premises. q Heat recovery minimises ventilation heat losses. q Controllable air exchange creates individually set microclimate. Design q The casing is made of polymer coated steel plates, internally filled with 9/16 thermal and sound insulation layer of PE foam. q The hinged front panel of the casing ensures easy access to the internals for maintenance. q The unit is powered via an integrated power pulser with a wide range supply voltage range from 100 to 240 V and frequency from 50 to 60 Hz. q The unit is supplied with a power cord and a plug for connection to power supply. q Compatible with round Ø 4 15 / 16 air ducts. Supply filter Extract filter Fans q Axial fans with EC motors provide air supply and air extract. q EC motor technologies meet the latest engineering demands for saving energy and for high-efficient ventilation. q Low energy demand due to implemented EC technologies. q The fan motors are equipped with a built-in thermal overheating protection and ball bearings for a long service life. Intake air Exhaust air Core Heat recovery q The unit is equipped with a plate counter-flow plastic core with a large surface area and high heat recovery efficiency. q Heat recovery efficiency reaches 79 %. q The air flows are fully separated within the core. Odours and contaminants contained in the extract air are not transferred to the supply air flow. q Heat recovery is based on extract air heat recovery for warming up of suply air. Extract air transfers most of its heat to the intake air flow. Heat recovery reduces heat losses in cold seasons. In summer the core performs reverse and transfers a part of the accumulated coolness from the cooled extract air for cooling down of the intake air. This contributes to better performance of the air conditioner in ventilated premises. q The integrated freezing protection system switches the supply fan off in the cold season in case of a freezing danger communicated by the temperature sensor to enable warming of the core with the warm extract air flow. When a freezing danger is over the supply fan turns on and the unit reverts to the standard operation mode. Air filtration q Supply and extract air cleaning with two MERV 4 filters. q The filters ensure fresh air supply, free of dust, insects and prevent contamination of the unit components. Control q The unit is operated with an external sensor speed switch that enables switching the unit on/off as well as setting low, medium or high speed mode. 2

Mounting q Install one FRESHBOX 60 unit in each room requiring ventilation. q One unit is able to provide efficient ventilation in a premise with area up to 269.1 ft 2. q Surface wall mounting on an outside wall from inside the premise. q Suitable for wall thickness from 3 15 / 16 up to 19 11 / 16. q The hole spacing for Ø 4 15 / 16 air ducts with a master plate included into the delivery set. q Install the AH FRESHBOX 60 outer hood (separate order, ref. accessories) on the outer wall. Technical data Overall and mounting dimensions Parameters FRESHBOX 60 Voltage [V] /50-60 Hz 100-240 Speed 1 2 3 Power [W] 4.2 9.6 15.4 Current [A] 0.02 0.04 0.07 Air capacity [CFM] 17.7 26.5 35.3 RPM 1165 1720 2685 Noise level [Sones] 0.38 0.42 1.0 Max. transported air temperature [ F] -4 up to +122 Filter: extract/supply MERV 4 Heat recovery efficiency [%] 79 74 70 SEC Class B Core type counter-flow Core material polystyrene SEC class B 20 11/16" 4 3/4" 15 1/2" 4 7/8" 6 1/4" 7 3/8" Accessories MS1 FRESHBOX 60 mounting kit: cardboard master plate (2 items); plastic Ø 4 15 / 16, 19 11 / 16 long air duct (2 items). For capital construction or refurbishment. The air ducts are mounted at the preparatory construction stage. The unit and the ventilating hood are mounted during a final construction stage. MS2 FRESHBOX 60 mounting kit: cardboard master plate (1 item); plastic Ø 4 15 / 16, 19 11 / 16 long air duct (2 items); stainless steel outer hood. Fully-featured solution for a complete single-stage unit mounting. 3 AH FRESHBOX 60 ventilation hood: Stainless steel outer hood. For air intake / exhaust and prevention of water and foreign objects ingress into the unit.

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS FRESHBOX 100 Air capacity up to 59 CFM Heat recovery efficiency up to 96 % Use q Heat recovery single-room air handling unit for supply and exhaust ventilation. q Efficient energy-saving single-room ventilation of flats, houses, cottages, social and commercial premises. q Ideal solution for simple and efficient ventilation of new or refurbished premises. q Heat recovery minimises ventilation heat losses. q Controllable air exchange creates individually set microclimate. Design q Polymer coated metal casing decorated with an acrylic front panel. q Heat and noise insulation is ensured by a layer of 3 / 8 cellular synthetic rubber. q The front panel provides convenient access for filter maintenance and has a lock for extra security. q The unit has two Ø 3 15 / 16 pipes for fresh air intake and stale air extraction outside. q The third Ø 3 15 / 16 pipe (included in the scope of delivery) can be additionally fitted to the unit to connect the exhaust air duct from the bathroom. q Electric preheating or post-heating is available for cold climate conditions. Air filtration q Supply air cleaning is provided by the MERV 8 and MERV 15 panel filters (PM2.5 > 75 %). q To meet more stringent air purity requirements the MERV 15 filter can be replacedwith an HEPA Filters (PM2.5 > 95 %) (purchased separately). q Exhaust air is cleaned by the panel filter MERV 8. Fans q The units feature efficient electronically commutated (ЕС) motors with an external rotor and impellers with forward curved blades. q These state-of-the-art motors are the most advanced solution in energy efficiency today. q In addition to that the efficiency of electronically commutated motors reaches very impressive levels of up to 90 %. q The unit is equipped with supply and exhaust air dampers which activate automatically to prevent drafts while the unit is off. MERV 8 Filter MERV 15 Filter Heat recovery q The FRESHBOX 100 units are equipped with a counter-flow polystyrene heat recovery core. q In the cold season the exhaust air heat is captured and transferred to the supply air stream which reduces the ventilation-generated heat losses. Some con densate may form during heat recovery. The condensate is collected in the drain pan and is removed from the exhaust air duct. q In the warm season the intake air heat is transferred to the extract air stream. This allows for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning load. q The FRESHBOX 100 ERV units are equipped with a counter-flow core with an enthalpy membrane at the core. q In the cold season the exhaust air heat and moisture are transferred to the supply air stream through the enthalpy membrane reducing the heat losses through ventilation. Consequently, it is the intake air heat and moisture transferred to the extract air stream through the enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the air conditioning load. Heating q FRESHBOX E-100 units are equipped with an electric preheater which protects the core from freezing. q FRESHBOX E1-100 units feature an electric post-heater to raise the supply air temperature as necessary. q ЕН FRESHBOX 100 heater for condensate freeze protection (optional). Operation in a cold climate may result in condensate freezing in the exhaust air duct and the external hood. Therefore, it is recommended to install the ЕН FRESHBOX 100 heater (pur chased separately) to prevent icing. Control q Freeze protection. There are two types of freeze protection available to protect the core in the cold season. 4

Control q The unit is equipped with a control panel. q The remote control is supplied as standard. Freshbox 100 Freshbox E-100 q Freeze protection. There are two types of freeze protection available to protect the cores in the cold season. q FRESHBOX 100 features an exhaust air temperature sensor downstream of the core which disables the supply fan to let the warm extract air warm up the core. After that the supply fan is turned on and the unit reverts to the normal operation mode. The FRESHBOX E-100 units are equipped with an electric preheater which warms up the supply air upstream of the core to prevent its freezing. Freshbox E1-100 Speed changeover + + Filter replacement indication + + Alarm indication + + Speed setting + + Timer + + Weekly schedule + + Post-heating enabled/disabled + Supply air temperature setup + Mounting q Each space requiring proper ventilation is equipped with one or several FRESHBOX 100 units. q A single unit is capable of ensuring efficient ventilation in spaces with area up to 645.3 ft 2. FRESHBOX 100 application in an office space q The FRESHBOX 100 units can be upgraded with a bathroom exhaust air duct. q To enable such a configuration the units can be additionally equipped with an optional Ø 3 15 / 16 spigot (supplied as standard). Operating principle q The cold outdoor air passes through the filters and the core and then is delivered to the serviced space by the supply centrifugal fan. q Warm stale air from indoors passes through the filter and the core and is discharged outdoors by the centrifugal fan. q The supply and exhaust air flows are fully separated which helps eliminate the possibility of odour or microbial transfer between the streams. FRESHBOX 100 application in a compact residential space 5

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS Technical data Parameters Freshbox 100 Freshbox 100 ERV Freshbox E-100 Freshbox E-100 ERV Freshbox E1-100 Freshbox E1-100 ERV Speed 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 Unit voltage [V /50-60 Hz] 1~120-230 Max. unit power without an electric heater [W] 12 21 45 12 21 45 12 21 45 12 21 45 12 21 45 12 21 45 Preheating power [W] 600 600 Post-heating power [W] 350 350 Max. current consumption w/o electric heater [A] 0,35 0,35 0,35 0,35 0,35 0,35 Max. current consumption with an electric heater [A] 3,08 3,08 1,94 1,94 Maximum air capacity [CFM] 18 36 59 18 36 59 18 36 59 18 36 59 18 36 59 18 36 59 RPM [min -1 ] max 2200 Noise level @ 9.9 ft. [Sones] 0.6 1.1 2.4 0.6 1.1 2.4 0.6 1.1 2.4 0.6 1.1 2.4 0.6 1.1 2.4 0.6 1.1 2.4 Max. transported air temperature [ F] from -13 up to +140 Casing material polymer coated steel Insulation 10 Extract air filter FP 193x158x18 G4 PPI (MERV 8) Intake filter FP 193x158x47 G4 PPI (MERV 8) + FP 193x158x47 F8 (MERV 15). Optional: FP 193x158x47 F8 C (MERV 15), FP 193x158x47 H13 (HEPA Filter). FP 193x158x47 G4 PPI (MERV 8) Connected air duct diameter [in] 3 15/16 Heat recovery efficiency [%] 96 92 87 90 86 80 96 92 87 90 86 80 96 92 87 90 86 80 Core type counter-flow Core material polystyrene enthalpic membrane polystyrene enthalpic membrane polystyrene enthalpic membrane Energy efficiency class А 6

Overall dimensions 23 1/4" 7 7/8" 27 3/16" 3 15/16" 15 3/4" 10 1/8" Freshbox 100 7

HEAT AND ENERGY RECOVERY SINGLE-ROOM UNITS VENTO Expert A50-1 Pro Air capacity up to 29 CFM Heat recovery efficiency up to 97 % Use q Arrangement of efficient energy-saving supply and exhaust single-room ventilation in flats, houses, cottages, social and commercial premises. q Reducing heat losses caused by ventilation due to heat recovery. q Humidity balance and regulated air exchange create individually controlled microclimate. q Coordinated network based on several integrated single-room ventilation units with central control. Design sound insulating material air duct outer ventilation hood decorative front panel reversible fan with EC motor ceramic ERV core filter MERV 15 (optional) sensor operation mode switches filters MERV 7 remote control Easy maintenance. Indoor unit is opened by pressing the latches on both sides. One of the best recovery efficiency on the market due to innovative hexagonal structure of the core cells. Integrated automatic air shutters prevent air back drafting. The specially designed front panel can be closed manually to ensure 100 % air tightness and protect against wind impact. 8

q Unit operating logic in winter period Phase 1 (70 seconds) Air extraction from the premise Phase 2 (70 seconds) Air supply to the room OUTSIDE +68 F INDOOR +62.6 F OUTSIDE +19.4 F +14 F Warm stale air is extracted from the premise, flows through the ceramic core and transfers its heat energy and moisture to it. As the ceramic core gets warmed up, the unit switches to the supply mode. Clean cold intake air flows through the core and absorbs accumulated heat and humidity. When the ceramic core is cooled down, the unit switches to the extract air mode. Control q Control of the unit operation mode is performed by means of sensor control panel located on the unit casing or a remote controller. ON/OFF button 3 unit speeds Speed selection and OFF button Energy recovery mode Ventilation mode Energy recovery mode Night timer: low speed for 8 hours Ventilation mode Party timer: high speed for 4 hours The unit is equipped with a humidity sensor for indoor humidity control. Connection of the units in series ensures balanced ventilation. First unit in the chain becomes the master one. Ventilation mode of the entire system can be controlled by means of the control panel on the master unit. A signal from the remote control is received by the master unit only. VENTO Expert A50-1 Pro VENTO Expert A50-1 Pro VENTO Expert A50-1 Pro VENTO Expert A50-1 Pro remote control ~ 100-230 V control line control line control line power line power line power line 9

HEAT AND ENERGY RECOVERY SINGLE-ROOM UNITS Mounting q The unit is designed for through-the-wall installation inside a prepared hole in an outer wall of the building. q The best ventilation solution is pairwise installation of reverse phase connected units. Some units ensure supply of fresh air to the room and the other units extract air from the premise. This way the most efficient balanced ventilation is arranged. q In case of brand new construction, units are mounted in two stages: Pre-installation at the stage of the indoor finishing and outer decorative wall finishing. It includes installation of an air duct, an outer ventilation hood and cable installation.; Final mounting before commissioning of a house. It includes installation of a core with a fan and filters and mounting and wiring of an indoor unit with a controller and shutters. Balcony Hall Bathroom Kitchen Technical data Speed 1 2 3 Voltage / 50-60 Hz [V] 100-230 Power [W] 3.61 4.15 5.20 Current [A] 0.025 0.030 0.039 RPM [min -1 ] 800 1300 1900 Air capacity in airing mode [CFM] 9 19 29 Air capacity in heat energy recovery [CFM] 4.5 9.5 14.5 Filter MERV 7 (MERV 15 PM2.5 > 75 % option) Temperature of transported air [ o F] -22 +122 Noise level @ 3.3 ft. [Sones] 0.6 1.0 1.2 Noise level @ 9.9 ft. [Sones] 0.3 0.5 0.6 Recovery efficiency [%] in accordance with DIBt LÜ-A 20 97 90 82 SEC class A Ingress protection rating IP24 10

Overall dimensions 11" 12 3/16" 11 13/16" 6 5/16" 9 1/4" 9 1/4" 11 1/4" 9 13/16"-19 11/16" 2 13/16" 11 1/4" 10 1/4" 6 5/16" 5 7/8"-19 11/16" 2 13/16" Accessories Vento Expert A50-1 Pro Vento Expert A50-1 S Pro Accessory name Description Pre-installation Kit VENTO Expert A50-1 q Includes: Air duct; AH 160 outer ventilation hood; Plastic foam plug. Pre-installation Kit VENTO Expert A50-1 S Completion Kit VENTO Expert A50-1 q Includes: Air duct; AH-S 160 outer ventilation hood; Plastic foam plug. q Includes: Internal unit with an energy recovery core, a fan and MERV 7 filters; Indoor unit with a controller and shutters; Remote control. Angular mounting into a wall with standard thickness using KIT BlauPlast 204x60-1 Filters set FP-VE A50 G3 q Includes: Filter 2 pcs. Filter FP-VE A50 F8 q Filtration rate PM2.5 > 75 % MERV 15 filter reduces airflow of the unit down to 24 CFM. FB-VENTO Expert q Remote control unit 11

HEAT AND ENERGY RECOVERY SINGLE-ROOM UNITS VENTO Expert A50-1 W Air capacity up to 29 CFM Heat recovery efficiency up to 97 % Use q Arrangement of efficient energy-saving, supply and exhaust, single-room ventilation in flats, houses, cottages, social and commercial premises. q Reducing heat losses caused by ventilation due to heat recovery. q Humidity balance and regulated air exchange create individually controlled microclimate. q Wi-Fi communication between several single-room ventilation units for coordinated operation. q Controlled by Android or ios smartphone or tablet. Design Fan with reversible EC motor Sound insulating material Air duct External ventilation hood Ceramic ERV core Decorative front panel Filter MERV 7 Filter MERV 7 Filter MERV 15 (Option) WLAN antenna On/Off Energy recovery mode Ventilation mode Humidity sensor Easy maintenance. Indoor unit is opened by pressing the latches on both sides. The specially designed front panel can be closed manually to ensure 100% air tightness and protect against wind impact. Integrated automatic air shutters prevent air back drafting. One of the best recovery efficiency on the market due to innovative hexagonal structure of the core cells. Speed Ventilation mode Energy recovery mode Nigh timer: low speed for 8 hours Party timer: high speed for 4 hours Built-in Wi-Fi for wireless communication between units and Android or ios device control 12

q Unit operating logic in winter period Phase 1 (70 seconds) Air extraction from the room Phase 2 (70 seconds) Air supply to the room OUTSIDE +68 F INDOOR +62.6 F OUTSIDE 19.4 F +14 F Warm stale air is extracted from the premise, flows through the ceramic core and transfers its heat energy and moisture to it. As the ceramic core gets warmed up, the unit switches to the supply mode. Clean cold intake air flows through the core and absorbs accumulated heat and humidity. When the ceramic core is cooled down, the unit switches to the extract air mode. Control q The units can be connected by Wi-Fi for synchronized operation. The units can be connected by Wi-Fi. Blauberg Vento app for Android or ios devices is available at Google Play and App Store. The Vento Expert A50-1 W unit can be connected to a laptop for advanced settings: q Master or slave q Supply or exhaust operation in ventilation mode q Connection through a Wi-Fi router or directly to a smartphone. A humidity sensor is built into the unit An external CO 2 sensor can be connected to the unit 13

HEAT AND ENERGY RECOVERY SINGLE-ROOM UNITS Mounting q The unit is designed for through-the-wall installation inside a pre pared hole in an outer wall of the building. q The best ventilation solution is pairwise installation of reverse phase connected units. Some units ensure supply of fresh air to the room and the other units extract air from the premise. This way the most efficient balanced ventilation is arranged. q In case of brand new construction, units are mounted in two stages: Pre-installation at the stage of the indoor finishing and outer decorative wall finishing. It includes installation of an air duct, an outer ventilation hood and cable installation; Completion of the installation before commissioning of a house. It includes installation of the indoor unit with controller and shutters, the cartridge, the core, the fan and the filters. Vento Expert Balcony Overall dimensions Vento Expert 11" 12 3/16" 11 13/16" 6 5/16 9 1/4 10 1/4" 6 5/16 9 1/4 Vento Expert Hall 11 1/4 5 7/8-19 11/16 11 1/4 Bathroom Kithen Vento Expert Vento Expert DUO Vento Expert DUO 9 13/16-19 11/16 2 13/16 Vento Expert A50-1 W 2 13/16 Vento Expert A50-1 S W (for thin walls) Technical data Parameters VENTO EXPERT A50-1 W / VENTO EXPERT A50-1 S W Speed 1 2 3 Voltage / 50-60 Hz [V] 100-230 Power [W] 4.45 5.08 7.06 Current [A] 0.035 0.040 0.059 RPM [min -1 ] 800 1300 1900 Air capacity in airing mode [CFM] 9 18 29 Air capacity in energy recovery mode [CFM] 4.5 9 14.5 Filter MERV 7 (MERV 15 PM2.5 > 75 % option) Temperature of transported air [ o F] -22 +122 Noise level @ 3.3 ft. [Sones] 0.6 1.0 1.2 Noise level @ 9.9 ft. [Sones] 0.3 0.5 0.6 Recovery efficiency [%] in accordance with DIBt LÜ-A 20 97 90 82 SEC class A Ingress protection rating IP24 Angular mounting into a wall with standard thickness using KIT BlauPlast white 160 / KIT BlauPlast chrome 160 14

Accessories Accessory name Description Pre-installation Kit VENTO Expert A50-1 Includes: Air duct; AH 160 outer ventilation hood; Plastic foam plug. Pre-installation Kit VENTO Expert A50-1 S Completion Kit VENTO Expert A50-1 Includes: Air duct; AH-S 160 outer ventilation hood; Plastic foam plug. Includes: Internal unit with an energy recovery core, a fan and MERV 7 filters; Indoor unit with a controller and shutters; Remote control. KIT BlauPlast white 160 Mounting kit for angular installation in walls with standard thickness FP Vento Expert A50 G3 MERV 7 filters (2 pcs.) FP Vento Expert A50 F8 Includes: Plastic frame (1 pc.) MERV 4 pre-filter (1 pc.) MERV 15 filter (1 pc.) Filtration rate PM2.5 99 %. MERV 15 filter reduces airflow of the unit down to 18 CFM FB Vento Expert Remote control unit CD-1 CO 2 sensor with LED indication and On/Off button CD-2 CO 2 sensor 15

HEAT AND ENERGY RECOVERY SINGLE-ROOM UNITS VENTO Expert DUO A30-1 Pro Air capacity up to 18 CFM Heat recovery efficiency up to 85 % Use q Arrangement of supply and exhaust ventilation with heat recovery in wet rooms like kitchen, bathroom, utility room; q Balanced ventilation due to simultaneous supply and exhaust ventilation; q Protection from outdoor noise; q Reducing heat losses caused by ventilation due to heat recovery; q Humidity control by means of built-in humidity sensor. Design Air duct Air streams separator Decorative front panel Reversible EC fans Ceramic ERV core Outer ventilation hood MERV 7 filters Operation mode switches Remote control One of the best recovery efficiency on the market due to innovative hexagonal structure of the core cells. Easy maintenance. Indoor unit is opened by pressing the latches on both sides. 16

q Unit operating logic in winter period Phase 1 (70 seconds) Phase 2 (70 seconds) +68 F +19.4 F +62,6 F +14 F INDOOR OUTDOOR INDOOR OUTDOOR +62.6 F +14 F +68 F + 19,4 F One fan supplies fresh and cold air from outdoor, which flows through the correspondent part of the ceramic core and absorbs accumulated heat and humidity. At the same time, another fan extracts slate and warm air from indoor, that flows through the other part of the ceramic core and transfers heat energy and moisture to it. After 70 second of operation, fans change their directions of rotations to the opposite ones, and everything happens vice versa. Control q Control of the unit operation mode is performed by means of smartphone, sensor control panel located on the unit casing or a remote controller. ON/OFF button Speed selection and OFF button Energy recovery mode Ventilation mode 3 unit speeds Ventilation mode Energy recovery mode Night timer: low speed for 8 hours Party timer: high speed for 4 hours q Vento Expert DUO either can operate as independent unit, or can be wired with other units in a house to be controlled with a master unit. In this case, only the master unit receives a signal from the remote control. q Vento Expert DUO is equipped with a humidity sensor for indoor humidity control. If humidity will rise higher than set point, than the unit will boost independently from other units in the system. A humidity sensor is built into the unit An external CO 2 sensor can be connected to the unit 17

HEAT AND ENERGY RECOVERY SINGLE-ROOM UNITS Mounting The unit is designed for through-the-wall installation inside a prepared hole in an outer wall of the building. Vento Expert DUO should be installed in each wet room (kitchen, bathroom etc.), which requires ventilation, while Vento Expert should be installed in each living room, which require ventilation. Vento Expert Balcony Vento Expert Vento Expert Hall Bathroom Kitchen Vento Expert DUO Vento Expert DUO Vento Expert Overall dimensions 12 3/16" 6 5/16" 9 1/4" 10 1/4" 11 1/4" 11"-19 11/16" 2 13/16" Vento Expert DUO A30-1 Pro 18

Technical data Parameters VENTO EXPERT DUO A30-1 Pro Speed 1 2 3 Voltage / 50-60 Hz [V] 100-240 Power [W] 2.17 3.66 6.62 Current [A] 0.026 0.039 0.066 RPM [min -1 ] 1600 2200 2500 Air capacity in airing mode [CFM] 6 12 18 Air capacity in energy recovery mode [CFM] 3 6 9 Filter MERV 7 (MERV 15 PM2.5 > 75 % option) Temperature of transported air [ o F] -22 +122 Noise level @ 3.3 ft. [Sones] 1.2 2.0 2.5 Noise level @ 9.9 ft. [Sones] 0.5 1.0 1.2 Recovery efficiency [%] in accordance with DIBt LÜ-A 20 85 80 75 SEC class A Ingress protection rating IP24 Accessories Accessory name FP VENTO Expert DUO A30 G3 FB VENTO Expert A50 Description MERV 7 filter kit (2 pcs.) Remote control 19

HEAT AND ENERGY RECOVERY SINGLE-ROOM UNITS VENTO Expert DUO A30-1 W Air capacity up to 18 CFM Heat recovery efficiency up to 85 % Use q Arrangement of balanced energy saving, supply and exhaust, single-room ventilation in kitchen, bathroom and utility room. q Reducing heat losses caused by ventilation due to heat recovery. q Humidity balance and regulated air exchange create individually controlled microclimate. q Wi-Fi communication between several single-room ventilation units for coordinated operation. q Controlled by Android or ios smartphone or tablet. Design Air duct Air streams separator Decorative front panel Reversible EC fans Ceramic ERV core Outer ventilation hood MERV 7 filters Operation mode switches Remote control One of the best recovery efficiency on the market due to innovative hexagonal structure of the core cells. Built-in Wi-Fi for wireless communication between units and Android or ios device control 20

q Unit operating logic in winter period Phase 1 (70 seconds) Phase 2 (70 seconds) +68 F +19.4 F +62.6 F +14 F INDOOR OUTDOOR INDOOR OUTDOOR One fan supplies fresh and cold air from outdoor, which flows through the correspondent part of the ceramic core and absorbs accumulated heat and humidity. At the same time, another fan extracts slate and warm air from indoor, that flows through the other part of the ceramic core and transfers heat energy and moisture to it. After 70 second of operation, fans change their directions of rotations to the opposite ones, and everything happens vice versa. Control q Control of the unit operation mode is performed by means of smartphone, sensor control panel located on the unit casing or a remote controller. ON/OFF button Speed selection and OFF button Energy recovery mode Ventilation mode 3 unit speeds Ventilation mode Energy recovery mode Night timer: low speed for 8 hours Party timer: high speed for 4 hours q Vento Expert DUO A30-1 W either can operate as independent unit, or can be wired with other units in a house to be controlled with a master unit. In this case, only the master unit receives a signal from the remote control. q Vento Expert DUO A30-1 W is equipped with a humidity sensor for indoor humidity control. If humidity will rise higher than set point, than the unit will boost to high speed independently from other units in the system. A humidity sensor is built into the unit An external CO 2 sensor can be connected to the unit 21

HEAT AND ENERGY RECOVERY SINGLE-ROOM UNITS The units can be connected by Wi-Fi. Blauberg Vento app for Android or ios devices is available at Google Play and App Store. VENTO Expert Duo A30-1 W VENTO Expert A50-1 W q The Vento Expert DUO A30-1 W unit can be connected to a laptop for advanced settings: Master or slave Connection through a Wi-Fi router or directly to a smartphone. Mounting q VENTO Expert A50-1 W units should be installed in the living room and bedrooms while VENTO Expert DUO A30-1 W should be installed in kitchen, bathrooms and utility room. q The unit is designed for through-the-wall installation inside a prepared hole in an outer wall of the building. Vento Expert Balcony Overall dimensions Vento Expert 12 3/16" 6 5/16" 9 1/4" Vento Expert Hall 10 1/4" Bathroom Kithen 11 1/4" Vento Expert DUO Vento Expert DUO 11"-19 11/16" 2 13/16" Vento Expert VENTO Expert DUO A30-1 W 22

Technical data Parameters VENTO EXPERT DUO A30-1 W Speed 1 2 3 Voltage / 50-60 Hz [V] 100-240 Power [W] 2.17 3.66 6.62 Current [A] 0.026 0.039 0.066 RPM [min -1 ] 1600 2200 2500 Air capacity in airing mode [CFM] 6 12 18 Air capacity in energy recovery mode [CFM] 3 6 9 Filter Temperature of transported air [ o F] MERV 7 (MERV 15 PM2.5 > 75 % option) -22 +122 Noise level @ 3.3 ft. [Sones] 1.2 2.0 2.5 Noise level @ 9.9 ft. [Sones] 0.5 1.0 1.2 Recovery efficiency [%] in accordance with DIBt LÜ-A 20 SEC class Ingress protection rating 85 80 75 A IP24 Accessories Accessory name FP VENTO Expert DUO A30 G3 FB VENTO Expert A30 Description MERV 7 filter kit (2 pcs.) Remote control 23

HEAT AND ENERGY RECOVERY SINGLE-ROOM UNITS VENTO Ergo A50 Pro1 VENTO Ergo A50-1 Pro1 Air capacity up to 29 CFM Heat recovery efficiency up to 88 % Use q Arrangement of efficient energy-saving supply and exhaust single-room ventilation in flats, houses, cottages, social and commercial premises. q Heat recovery minimises ventilation heat losses. q Humidity balance and controllable air exchange create individually set microclimate. q Coordinated network based on several integrated single-room ventilation units with central control. Design Plastic telescopic air duct AH-S ventilation outer hood for thin walls (included into VENTO Ergo A50 S Pro1 / Ergo A50-1 S Pro1 delivery set) Ventilation unit with automatic shutters (included into VENTO Ergo A50-1 Pro1 / Ergo A50-1 S Pro1 delivery set) Ceramic ERV core with antibacterial coating Mounting plate Three-position switches MERV 15 Filter (Option) MERV 7 filters with antibacterial coating Ventilation unit with automatic shutters (included into VENTO Ergo A50 Pro1 / Ergo A50 S Pro1 delivery set) Reversible axial fan with EC motor, integrated overheating protection and ball bearings AH outer ventilation hood for standard wall thickness (included into VENTO Ergo A50 Pro1 / Ergo A50-1 Pro1 delivery set) The fan is off (The shutters are CLOSED) The fan is on (The shutters are OPENED) Heat and moisture recovery q High-tech ceramic energy recovery core with heat recovery up to 88 %. q Due to its cellular structure it has a larger heat transfer area surface and high efficiency. The energy recovery core is featured with excellent heatconducting properties and thermal energy storage capacity. 24

q Unit operating logic in winter period Phase 1 (70 seconds) Air extraction from the room Phase 2 (70 seconds) Air supply to the room OUTSIDE +68 F INDOOR +63 F OUTSIDE +19 F +14 F Warm stale air is extracted from the premise, flows through the ceramic core and transfers a part of the accumulated heat and moisture to it. In 70 seconds, after heating of the ceramic core, the unit switches to the supply mode. Clean cold intake air flows through the core and absorbs accumulated heat and humidity. In 70 seconds, after cooling of the ceramic core, the unit is switched to the extract air mode. Control q The unit operation mode control is performed by means of manual three-position switches located on the unit casing or using the remote controller. q The unit is equipped with a humidity sensor for indoor humidity control and regulation. q Connection of the units into one ventilation system provide balanced ventilation and central control. High speed Off Middle speed Ventilation Supply and exhaust ventilation with energy recovery Air supply q Remote control and operation mode selection: Unit activation/deactivation 3 unit speeds Passive air supply mode: The automatic shutters are opened, the fan does not run. Ventilation mode: The integrated units operate in permanent air supply or air extract mode depending on settings during mounting. The unit is set into air extract mode by default. Night mode: In the night the unit is switched to low speed mode by the photo sensor. Air supply mode: The unit operates in permanent air supply mode. Reversible ventilation with heat recovery: The unit switches from supply to extract mode and vice versa in set time periods and transfers the heat and moisture contained in the extract air to cold intake air in winter or the coolness in summer through the ceramic core. Humidity control mode: Set required humidity level (45, 55 or 65 %). The unit automatically maintains the comfortable set indoor humidity point. q Connection of several units in series enables their synchronous control by the first unit. The signal from the remote control is received by the first unit only. VENTO Ergo A50 Pro1 VENTO Ergo A50 Pro1 VENTO Ergo A50 Pro1 VENTO Ergo A50 Pro1 NO.1 NO.10 NO.11 NO.20 Remote control 100-230 V 100-230 V 25

HEAT AND ENERGY RECOVERY SINGLE-ROOM UNITS Mounting q The unit is designed for external through-the-wall installation inside a prepared round hole in the outer wall of the building. q The best ventilation solution is pairwise installation of reverse phase connected units. Some units supply fresh air to the room and the other units extract stale air from the room. This allows to arrange the most efficient balanced ventilation. q In case of brand new construction the units are mounted in two stages: pre-installation at the stage of the indoor finishing and outer decorative wall finishing. It includes installation of the telescopic air ducts, outer ventilation hood and laying out of electric cables. final mounting before commissioning of a house. It includes installation of the core, the filters, connection of the ventilation unit. q If mounting of the ventilation hood on the outer wall is undesirable it may be flush mounted and the external grille may be inserted into the outer window jamb using the KIT BlauPlast 204x60-1 pre-installation kit. Available upon separate order. Balcony VENTO Ergo A50-1 S Pro1 unit installation example into a thin wall VENTO Ergo A50 Pro1 unit installation example into a wall with standard thickness Hall Bathroom Kitchen Technical data Parameters VENTO Ergo A50 Pro1 / Ergo A50-1 Pro1 VENTO Ergo A50 S Pro1 / Ergo A50-1 S Pro1 Speed 1 2 3 Voltage / 50-60 Hz [V] 1 ~ 100-230 Power [W] 4.5 5 7 Current [A] 0.024 0.026 0.039 Air capacity [CFM] 12 19 29 Sound pressure level at 3.3 ft. [Sones] 0.4 0.7 1.0 Sound pressure level at 9.9 ft. [Sones] 0.2 0.4 0.5 Recovery efficiency [%] 88 83 75 Maximum transported air temperature [ F] from -4 to +122 SEC class Ingress protection rating A IP24 Angular mounting into a wall with standard thickness using KIT BlauPlast 204x60-1 26

10 1/4" 11 13/16" 11 13/16" Overall dimensions 11" 11" 12 3/16" 12 3/16" 6 3/16" 6 3/16" 6 3/16" 6 3/16" 8 3/8 9 7/16 8 3/8 10 1/4" 9 7/16 9 7/16-16 3/4 2 1/4" 9 7/16-16 3/4 3 1/8 4 3/4-11 13/16 2 1/4 4 3/4-11 13/16 3 1/8 VENTO Ergo A50 Pro1 VENTO Ergo A50-1 Pro1 VENTO Ergo A50 S Pro1 VENTO Ergo A50-1 S Pro1 Accessories Accessory name Description Pre-installation Kit VENTO Ergo A50 Pro1 Completion Kit VENTO Ergo A50 Pro1 Completion Kit VENTO Ergo A50-1 Pro1 FB-Vento Ergo KIT BlauPlast 204x60-1 FP Vento Ergo A50 G3 FP Vento Ergo A50 F8 AH white 150 AH chrome 150 AH-S grey 150 AH-S chrome 150 q Includes: Round Ø 5 15 / 16" air duct AH 150 outer ventilation hood Plastic foam plug q Includes: Ceramic core Ø 5 15 / 16" VENTO Ergo A50 ventilation unit MERV 7 filters Mounting plate Remote control q Includes: Ceramic core Ø 5 15 / 16" VENTO Ergo A50-1 ventilation unit MERV 7 filters Mounting plate Remote control q Remote control Installation kit for angular mounting q Includes: Plastic ventilation grille 9 1 / 16" x 3 3 / 8" Plastic air duct 8" x 2 3 / 8" Plastic connecting bend from Ø 5 15 / 16" to 8" x 2 3 / 8" q MERV 7 filter kit (2 pcs) q MERV 15 filter (1 pc) q White painted aluminium hood q Brushed stainless steel hood q Grey painted stainless steel hood for thin walls q Brushed stainless steel hood for thin walls 27

HEAT AND ENERGY RECOVERY SINGLE-ROOM UNITS Vento ECO2 A50 S1 Pro Air capacity up to 29 CFM Heat recovery efficiency up to 92 % Filtration PM2.5 up to 99 % Use q Arrangement of efficient energy-saving supply and exhaust single-room ventilation in flats, houses, cottages, social and commercial premises q Air purification with optional MERV 15 filter PM2.5 99 % q Protection from outdoor noise q Reducing heat losses caused by ventilation due to heat recovery q Humidity balance and regulated air exchange create individually controlled microclimate Design VENTO Eco2 A50 S1 Pro consist of two ventilation units and one control panel. Internal grille with manually actuated shutters and a decorative panel Air duct Ceramic ERV core Reversible fan with EC motor Outer grille Noise insulating layer MERV 7 filters 28

Unit operating logic in winter period Phase 1 (70 seconds) Air extraction from the room Phase 2 (70 seconds) Air supply to the room OUTDOOR INDOOR OUTDOOR + 19,4 F +68 F +62,6 F + 14 F Warm stale air is extracted from the premise, flows through the ceramic core and transfers its heat energy and moisture to it. As the ceramic core gets warmed up, the unit switches to the supply mode. Control q Control of the unit operation mode is performed by means of the sensor control panel. Clean cold intake air flows through the core and absorbs accumulated heat and humidity. When the ceramic core is cooled down, the unit switches to the extract air mode. "Party" timer: max speed for 4 hours Energy recovery mode Speed 3 Filter maintenance indication Speed 2 Ventilation mode Speed 1 Alarm indication "Night" timer: min speed for 8 hours ~100-240 V One control panel with sensor buttons is able to operate up to two units. Low voltage (12V) power supply between control panel and Vento Eco units. 29

HEAT AND ENERGY RECOVERY SINGLE-ROOM UNITS Mounting q The unit is designed for through-the-wall installation inside a prepared hole in an outer wall of the building. q One unit can ventilate a room up to 269.1 ft 2. For bigger rooms two or more units must be installed. Vento ECO A50 S1 Pro VENTO Eco2 A50 S1 Balcony VENTO Eco A50 S1 VENTO Eco2 A50 S1 Hall Bathroom Kitchen Vento ECO A50 S Pro VENTO Eco A50 S1 Technical data Parameters VENTO ECO2 A50 S1 PRO Speed 1 2 3 Voltage / 50-60 Hz [V] 100-240 Power [W] 2.07 4.15 10.10 Current [A] 0.030 0.049 0.098 RPM [min -1 ] 1030 1760 2690 Air capacity in airing mode [CFM] 9 18 29 Filter MERV 7, MERV 15 (Option) Temperature of transported air [ o F] -22 +122 Noise level @ 3.3 ft. [Sones] 0.6 1.0 1.2 Noise level @ 9.9 ft. [Sones] 1.3 0.5 0.6 Heat recovery efficiency [%] 92 86 78 Ingress protection rating IP24 30

Overall dimensions Vento ECO2 A50 S1 Pro 9 7/16" 5 9/16" Vento ECO2 A50 S Pro 7 7/8" 3 3/8" 3 3/8" 1/2" 1 1/8" 6 5/16" 1 11/16" 12 3/16"-19 11/16" 6 5/16" 8 1/4"-19 11/16" 7 7/8" 9 1/2" Accessories Accessory name Completion Kit Vento Eco A50 SE Vento Eco A50 Pro Rohr 160-500 Rohr 160-700 AH chrome 160 AH-S chrome 160 Decor 150Fs An white KIT BlauPlast white 160 KIT BlauPlast chrome 160 FP Ventо Eco A50 G3 FP Vento Eco A50 F8 L Vento Eco A50 Description Cartridge with energy recovery core, fan and MERV 7 filters. Square and round indoor grille with manually actuated shutters Sensor control panel 19 11 / 16 air duct 27 9 / 16 air duct Outer hood made of brushed stainless steel Outer hood for thin walls made of brushed stainless steel Outer grille Kit for angular mounting with a white outer grille Kit for angular mounting with a stainless steel outer grille MERV 7 filters (2 pcs.) MERV 5 + MERV 15 filters (1 pc.) Filtration rate PM2.5 99 %. Combination of MERV 5 + MERV 15 filters reduces air flow down to 18 CFM Fan 31

WALL VENTS Solo A35 Series Use q Wall ventilator with heat and energy recovery Application q Supply clean fresh air to the premises q Remove stale extract air from the premise q Clean the air of dust and insects q Prevent penetration of excessive humidity and appearance of mould q Protect against outdoor noise q Recover heat and provide humidity balance inside q Reduce the heating costs in winter and air conditioning costs in summer q Low energy demand +19.4 F +62.6 F 70 s +68 F AIR EXTRACTION +68 F Operation logic q Energy is recovered due to reversing operation of the ventilator, which consists of two cycles: CYCLE I. As warm stale extract air flows through the ceramic core, it heats up and moisturizes the core. In 70 seconds as the ceramic core gets warmed the ventilator automatically switches to Air Supply mode. CYCLE II. Fresh, cold intake air from outside flows through the ceramic core, absorbs accumulated moisture and is heated to the room temperature. In 70 seconds as the core gets cooled down, the ventilator switches to Air Extract mode and the cycle is renewed. q The Air Supply and the Air Extract modes are switched every 70 seconds. Design q Fan Air is supplied or extracted by a reversible axial fan with EC motor. Due to EC technology the fan is distinguished with low energy demand. The motor has overheating protection and ball bearings for longer service life. q Air filters Two built-in filters with total filter class MERV 7 are used to clean supply and extract air flows. The filters ensure fresh air cleaning of dust and insects and prevent the ventilator parts from soiling. The filters are cleaned either with a vacuum cleaner or flushed with water. q Energy core The high-technology energy core is used for extract air heat energy recovery and supply air heating. The Solo A35A S4 Pro P is equipped with the aluminium energy core with recovery efficiency up to 75 %. The Solo A35 S4 Pro P is equipped with the ceramic energy core with recovery efficiency up to 85 %. -14 F Reversible fan Generates air flow by means of the fan rotation AIR SUPPLY 70 s -14 F +19.4 F +62.6 F Filter Cleans the air flowing of dust and foreign objects through the ventilator Core Provides extract air energy recovery for warming up of supply air flow Outer ventilation hood Prevents direct ingress of water and foreign objects into the ventilator Telescopic air duct 32

Technical data Solo A35A S4 Pro P Solo A35 S4 Pro P Speed 1 2 1 2 Voltage [V / 50-60 Hz] 120-230 Power [W] 1.43 1.92 1.36 1.89 Current [A] 0.032 0.034 0.031 0.034 Maximum air capacity [CFM] 14 21 18 27 Sound pressure level at 9.9 ft. distance [Sones] 0.8 1.3 0.8 1.3 Maximum transported air temperature [ F] from -22 up to +122 Heat recovery efficiency [%] 75 85 Core type Aluminum Ceramic Energy efficiency class A A Ingress protection rating IP 24 Overall and mounting dimensions Control Dimensions [in] Ø D B B1 L L1 L2 4 1 / 16 5 15 / 16 6 11 13 / 16-22 13 / 16 1 3 / 16 3 5 / 16 B1 L1 D Switch On/Off Speed switch (speed I-II) L2 B L Extract mode Mounting example Intake mode 33

Blauberg Ventilatoren GmbH Aidenbachstr. 52a D-81379 München info@blaubergventilatoren.de www.blaubergventilatoren.de Sales@ventsus.com VentsUS.com 11013 Kenwood Road, Cincinnati, Ohio 45242 Tel: 888-640-0925 513-348-3853 Fax: 513-268-4597 Sales Technical changes reserved. Illustrations and texts are non-binding. 11/2016