PRODUCT NUMBER: RD40 Plastic Filters AXP3 XL

Similar documents
PRODUCT NUMBER: Rd40 Aluminium Canister AXP3

PRODUCT NUMBER: Tuff Cut Latex

PRODUCT NUMBER: Quiet (Corded) Easy handling and better fit

PRODUCT NUMBER: Honeywell SuperOne FFP2 NR

Overview. Features & Benefits

PRODUCT NUMBER: QB3HYG Semi-Aural Banded

PRODUCT NUMBER: AirSoft (Red Vinyl Cord)

PRODUCT NUMBER: SP1000 Safety Eyewear, Black Frame, ClearLens

PRODUCT NUMBER: Smartfit Detectable

PRODUCT NUMBER: SmartFit (Corded)

PRODUCT NUMBER: FirePro OVER-PANTS

PRODUCT NUMBER: Laser Lite Single-Use (Corded)

PRODUCT NUMBER: Laser Trak Single-Use Detectable Earplug

PRODUCT NUMBER: Max (Uncorded)

PRODUCT NUMBER: N L

PRODUCT NUMBER: Max LS-500 Refill

PRODUCT NUMBER: FlamePro1 JACKET

PRODUCT NUMBER: FirePro PARKA

PRODUCT NUMBER: Honeywell ICOM

PRODUCT NUMBER: Viking V1 Multiple-Position Earmuff

PRODUCT NUMBER: Leightning L3s Headband Earmuff

PRODUCT NUMBER: SmartFit (Corded)

PRODUCT NUMBER: Leightning L0Ns Neckband Earmuff

PRODUCT NUMBER: Honeywell Adaptec. Frame Size : Wide Frame Color: Blue/Gray Lens Tint: Clear

PRODUCT NUMBER: Thunder T3s Headband Earmuff

PRODUCT NUMBER: Bilsom AM/FM Radio Hi-Vis Earmuff

PRODUCT NUMBER: Clarity C3 Headband Earmuff

CBRN filtration systems

PRODUCT NUMBER: Honeywell Turboshield Headgear

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Powered Air Purifying Respirator (PAPR) SAFETY, COMFORT, FLEXIBILITY. Compact Air 200 Series PAPR No Worry, No Guesswork

3M Safety Solutions - OH&ESD. 3M 3000 Series Half Mask Respirators. Light. face, on your. light. on your budget. The Power to Protect Your World

BUSINESS PLAN CEN/TC 79 RESPIRATORY PROTECTIVE DEVICES EXECUTIVE SUMMARY

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

Lead them to safety. Honeywell Safety Products. Honeywell can help you build an enduring culture of safety.

Page 1 of 5. Product Numbers & Ordering Information. Product Numbers. Details

Product Family Honeywell V-Maxx

Honeywell Safety Products

Multipoint temperature sensor

Firetect C. Fire protective products: Fire protective board

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

Air Purification Systems. Clearing the Air. Air Purification Systems. Air Purification Systems

Product Numbers & Ordering Information

The PPE Directive and the PPE Regulation

HazLoc Essential Guides:

Dryer Systems. Breathing Air Units

Technical Sheet. Heat recovery appliance Renovent Excellent 180 (Plus) Renovent Excellent 180 1

Assessment of plans. DI Thomas Knoll Knoll Planung & Beratung Vienna, Austria

MADEIRA. Normal care / Architectural concepts

REFLOW OVEN FT01 Version REFLOW OVEN FT01. (Article number F31105) User s Manual

The New PPE Regulation (EU) 2016/425

PPE Global Market Access Program

Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

Ariazone 601HD Refrigerant Recovery&Recycling unit

Operating instructions

MARKING EC Directive 97/23 PED (Pressure Equipment Directive)

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

Dräger X-plore 8000 Powered Air-Purifying Respirator (PAPR)

FROTH-PAK ULTRA Premium Foam Insulation Refill Kit and Accessories

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Do you manufacture equipment or protective systems for use in potentially explosive atmospheres? Do you process, trade or import them?

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

- SAFETY MANUAL - DAMPERS

BUSINESS PLAN. CEN/TC 137 Assessment of workplace exposure to chemical and biological agents EXECUTIVE SUMMARY

Operating Instructions

The New EMC Directive 2004/108/EC

MEDIVA LED. Normal care / Horizontal Bed head units. Dynamic Lighting

Miretti DetEx. the active core of Zone 2 Ex-Proof Conversions. Miretti DetEx enables your employees to work in safety

CE MARKING OF WOOD-BASED PANELS

Energy Saving Refrigerated Compressed Air Dryers DES Series 90 to 675 scfm (153 to 1148 nm 3 /h)

The transition requirements of the new Regulation (EU) 2016/425 of the European Parliament and of the Council on personal protective equipment

EUROPUMP ATEX Guideline Part II

Dräger QuadGard Control System

Regulation (EC) 1272/2008 on Classification, labelling and packaging. (CLP Regulation) DG Environment

Environmental Product Declaration

Dräger Configuration and Evaluation Software

The New EMC Directive 2004/108/EC

Part 2-55: Medical electrical equipment. Particular requirements for the basic safety and essential performance of respiratory gas monitors

Dräger Catalytic Ex-Sensors DrägerSensors

PHOENIX PNX DCI WALL MOUNTED RANGE AN AIRWELL GROUP COMPANY

Dry compressed air finally exits via a validated GL after-filter preventing the migration of particles into the downstream compressed air network.

Part No KEMPER Filter-Master XL

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

DECORATIVE WALLCOVERINGS - ROLL AND PANEL FORM PRODUCTS IRISH STANDARD I.S. EN 15102:2007. Price Code. Údarás um Chaighdeáin Náisiúnta na héireann

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

The Impact of Marking Requirements. on Design and Performance of Power Converters and Electrical Drives

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2018/C 209/02)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Dräger X-am 2500 Multi-Gas Detection

OPTIBAR DP 7060 Supplementary Instructions

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

HEATLESS REGENERATED ADSORPTION DRYER ULTRAPAC SMART

Multi line separator module

METHODOLOGY FOR TESTING PERSONAL

KEVA 20, 30 & 45 ATEX ELECTRIC VACUUM CLEANER OPERATOR MANUAL

OPERATING MANUAL UNIT 8 - WHITEBRIDGE INDUSTRIAL ESTATE STONE STAFFORDSHIRE ST15 8LQ ENGLAND TEL: +44 (0) FAX: +44 (0)

Eaton Contamination Control Products FT1555-BM bench mount capping machine operating instructions

Transcription:

Europe / Africa PRODUCT NUMBER: 1788166 RD40 Plastic Filters AXP3 XL Honeywell offers a broad choice of plastic canisters. Its plastic filter range covers many hazardous gases, vapors and /or particulates in many applications. The Honeywell plastic filter range provides a cost-effective protection, without compromise on its quality. This plastic filter is tested according to the EN14387 and the EN143 standard. Overview Reference Number 1788166 Product Type Respiratory Protection Range Reusable APR Brand Honeywell Brand formerly known as FERNEZ by Willson Industry Industry Product Use For use with full-face mask equipped with an RD40 connector For protection against organics gasses and vapours with a boiling point below 65 C and solid and liquid particles. s & Benefits Light and resistant plastic casing. Suitable for use in specific zone as free-metal zone and/or nuclear industry Performance requirements for gas and particles significantly above standard for excellent filtration efficiency over extensive period of time. Canister made of high-grade charcoal, additionally treated for optimal gas absorption. Specific canister structure for low breathing resistance and more comfort for the user Low profile so as not to obstruct the field of vision Page 1 Of 3

Multipurpose and can be used with existing respirators. PLASTIC CANISTER AXP3 XL - 1788166 Technical Description Filters Cartridges Standard Particle filters efficiency (EN143) EN14387 (Gas/vapours and combined filters for respiratory with negative pressure) - Conformed to the requirements of the European Community Directive 89/686/EEC (Personnal Protective Equipment), belongs to the EC Category III and is CE marked, followed by the identification of the certification body (0194), which assure the quality control (according to the article 11B). Protection Type Combination Connection Type RD40 Material ABS material with plastic cover High activated charcoal - Ø106mm - 390gr Certifications E.C. Declaration of Conformity EC Category PPE 3 Quality Assurance ISO 9001 / 2000 EC Certificate Number 0070-236-079-03-06-0008 EC Attestation EC Attestation EC Attestation Number 0070-236-079-03-06-0008 Declaration of conformity APAVE - 1788166 http://www.honeywellsafety.com/supplementary/documents_and_downloads/secured/pic_sku_- _certificates/4294989360/1033.aspx Additional Information User Manual User Manual Filters Maintenance Life Cycle Depends on absorption capacity, concentration of contaminant, humidity and user breathing Storage Information 4 years after date of manufacturing - Store the filters in a cool, dry, location with the caps attached - The maximum permissible storage period is specified on the filter - Storage temperature range: -20 C / +50 C - Maximum humidity during storage: 80% Care Instructions Controls before use Page 2 Of 3

Users must Ensure that the level of protection offered by the respirator is sufficient for the type and concentration of contaminant(s) in the work area Respect the shelf life figuring on the filter Check the seal points Limitations of use For use only by trained and qualified personal Do not use where the oxygen level or the atmosphere is less than 17% After use, an opened canister must be repacked properly with its caps if it is likely to be re-used. It must be replaced no later than within 6 months after opening. If a user identifies the break through of the canister by the smell or taste of a gas, the canister must be replaced immediately If the breathing resistance of the canister increased significantly, it must be changed. Filter with a mass over 300 g may not be used fitted directly onto half-masks AX and AXP3 canister are single use only. They must be replaced after each shift. Disposal PLASTIC CANISTER AXP3 XL - 1788166 Canister must be disposed in accordance with the local waste disposal regulations. Packaging EAN Code 7312557881661 Packaging Specs Individual Box 31 x 26 x 12 Unit of Measure CM Quantity per Box/Pack/Case Sales unit per box of 5 units of 1,950kg Page 3 Of 3

E.C. Declaration of Conformity The manufacturer or its legal representative supplier in the European Community: Honeywell Safety Products Europe Declares that the Personal Protective Equipment described here after conforms to the provisions of the European Council Directive 89/686/CEE: Designation: RD40 Plastic Filters AXP3 XL Reference: 1788166 Standard(s): EN14387 This PPE is the object of the below EC examination certificate n : 0070-236-079-03-06-0008 Delivered by: INRS Avenue de Bourgogne BP 27 54501 Vandoeuvre Cedex France Drawn up in Roissy, on the 02/05/2016 By: Division: Respiratory Protection Zl Paris Nord II 33, rue des Vanesses BP 50288 95958 Roissy CDG France Tel: +33 (0) 49 90 79 79 Fax: +33 (0)1 49 90 79 80 www.honeywellsafety.com