kw COOLING kw HEATING

Similar documents
Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

kw. technicalcatalogue

FRIGO SCREW CLA PLUS Packaged water cooled liquid chillers in A+ class energy efficiency for indoor installation. Cooling Capacity: kw

44,9 202,0 kw. technicalcatalogue

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

21,8 222 kw COOLING 25,2 236 kw HEATING

GLIDER EVO GLIDER EVO. rcgroupairconditioning

glider evo cla glider evo cla A-CLASS rcgroupairconditioning

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

kw. technicalcatalogue

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

EQUH PF PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR INDOOR INSTALLATION

pyxis pyxisa NEW rcgroupairconditioning

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

rcgroup.it Flooded evaporator Low noise Minimum starting current EER up to 5,25 ESEER up to 8,88

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

rcgroup.it Flooded evaporator Refrigerant charge HFO1234ze, GWP<1 Low noise Minimum starting current EER up to 5,41 ESEER up to 9,10

pyxis u pyxis ua NEW rcgroupairconditioning

frigo turbo FL Chillers

Kelvin air conditioning. KELVIN Clim W280. Cooling Capacity: 280 ~ 1840 kw

unico pf unico pf rcgroupairconditioning

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

EQPHU PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR OUTDOOR INSTALLATION

Kelvin air conditioning. KELVIN Clim W250. Cooling Capacity: 250 ~ 1240 kw

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

PYXIS U PYXIS U. rcgroupairconditioning

nemo a hp rcgroupairconditioning R410A

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

unico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning

KELVIN Clim F497. Kelvin air conditioning

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

NEXT DL NEXT DL. rcgroupairconditioning

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

next p dw next p dw rcgroupairconditioning

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

turb new unico turbo frigo turbo fl Liquid chiller equipped with magnetic levitation twostage centrifugal compressors RCGROUP SpA C_GNR_0711

Water chillers water/water type SIGMA Technical information manual

next DX.U.S* 052.Z2.H6.DC

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

TCHVZ TCEVZ

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

i-next DX kw FULL INVERTER direct expansion air conditioners for IT Cooling. To be matched with remote air-cooled condenser. rcitcooling.

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running

ARV.

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

COLDPACK_. water cooled chillers / heat pumps and condenserless chillers

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

LZT High efficiency air to water heat pumps with E.V.I. compressors

GLIDER_. air cooled liquid chilled chillers / heat pumps

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Conditioning your ambient, maximising your comfort.

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Aquaflair TRAC-TRAF-TRAH

Blue Box Epsilon Echos +

LZA High efficiency air to water heat pumps with HP compressor

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

WZH Ground source heat pumps

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

next NEXT EVO CW kw UP FLOW DOWN FLOW CHILLED WATER E C CLOSE CONTROL AIR CONDITIONERS FOR CHILLED WATER FEEDING,

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

Ultimate energy saving technology

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

coldpack water cooled chillers / heat pumps and motoevaporating units C_GNR_0508

Kälte Klima. Water cooled water chillers from 200 kw to 1550 kw. Screw Compressor LCWX DE 56 01/16 12/13

TCHE-THHE TCEE

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

H4T R410A. refrigerant

Air-to-water scroll chillers

Transcription:

Heat pump water/water liquid chillers for indoor installation. Inversion on hydraulic circuit. 394 1505 kw COOLING 477 1976 kw HEATING technicalcatalogue T_FRGSCRWP_0913_GB

INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 WORKING LIMITS... 4 COMPONENTS... 5 OPTIONAL ACCESSORIES... 7 TECHNICAL DATA... 8 ACOUSTIC DATA... 10 ELECTRIC DATA... 10 MP.COM: MICROPROCESSOR CONTROL SYSTEM... 11 OPTIONAL ACCESSORIES BRINE A KIT... 13 OPTIONAL ACCESSORIES BRINE B KIT... 13 OPTIONAL ACCESSORIES - PARTIAL HEAT RECOVERY SYSTEM... 14 UNIT DRAWINGS... 15 2 RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a

GENERAL CHARACTERISTICS FRIGO SCREW WP: Packaged heat pump water/water liquid chiller for chilled water production in summer time and hot water production in winter time (inversion on hydraulic circuit at Customer care). The machines are made for indoor installation. Framework with sections of thick steel for high resistance to the greatest stress during handling and transport. Machines supply fully assembled with refrigerant charge and control systems. The installation requires only electrical and hydraulic connections allowing costs and time savings. Final assembly on all machines before shipment including running test, reading and monitoring of operating parameters, alarms simulation and visual check. Design, assembly and test as per the Company Quality Assurance program in full compliance with ISO 9001:2008. RC Group has been the first Italian company in its segment to get the Company Quality Assurance in October 13 th, 1991 with certificate ICIM 0018. Environmental Management System Certification according to ISO 14001:2004. The machines are in full compliance with European Directive 2006/42CE, 2006/95CE, 2004/108CE, 97/23CE and subsequent amendments SERIES IDENTIFICATION FRIGO SCREW WP Packaged heat pump water/water liquid chiller equipped with equipped with screw compressors, shall and tube evaporator and condenser. R134a refrigerant charge. Cooling capacity Heating Capacity 394 1505 kw 477 1976 kw MODEL IDENTIFICATION FRIGO SCREW WP 410 V 2 410 Cooling capacity (kw) at nominal conditions V Twin-screw compressor 2 Compressor number RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a 3

Evaporator water outlet temperature WORKING LIMITS WORKING LIMITS IN COOLING / HEATING MODE ( C) 20 15 10 5 0 Use glycol solution Use glycol solution and BRINE A kit -5-10 -13 Use glycol solution and BRINE B kit 15 20 25 30 35 40 45 50 55 60 65 ( C) Condenser water outlet temperature 3 8 C Δt range between evaporator water inlet/outlet. PARTIAL HEAT RECLAIM Working limits for hot water production from partial heat reclaim system. The system is not regulated and the heating capacity which is supplied depends on the machine working conditions. 40 70 C hot water outlet temperature range 5 15 C Δt range between water inlet/outlet ANTIFREEZE MIXTURES Antifreeze mixtures has to be used when the machine working conditions foresees the chilled outlet liquid temperature as shown in the table: PROPYLENE GLYCOL Chilled outlet liquid temperature from the machine Percentage in weight of the mixture ETHYLENE GLYCOL Chilled outlet liquid temperature from the machine Percentage in weight of the mixture C 4 2 1-2 -4-6 -9-12 % 5 10 15 20 25 30 35 40 C 4 2 0-4 -7-9 -10-13 % 5 10 15 20 25 30 35 40 WARNING The values are referred to machine working temperature and not to freezing temperature of the used liquid. The use of antifreeze mixtures causes a reduction of the machine performance, Please refer to the RC WORLD electronic catalogue to obtain the effective performance. STORING TEMPERATURE If the machine is not installed on receipt and is stored for a long time, store it in a protected place, at temperatures ranging between -20 C and 50 C in absence of superficial condensation and direct sun light. 4 RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a

COMPONENTS FRAMEWORK Base and self supporting frame in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/ASTMB117 and ISO 7253, and painted with epoxy powders. Colour: RAL 9005 COMPRESSORS Twin screw semi-hermetic compressors with highly efficient screw profile and high peripheral speed, optimized for R134a refrigerant. Integrated discharge check valve. Flanged-on oil separator. Integrated overpressure valve. Replaceable cartridge type oil filter. Oil flow switch. Valves for oil filling and discharge. Sight glass Electronic protection device that includes: - Electric motor thermal protection via internal winding temperature sensors. - Phase sequence electronic relay - Sensor on refrigerant discharge for temperature monitoring, 2-pole 3-phase electric motor with Part-Winding starting for models 410 V2 / 460 V2 / 510 V2 / 540 V2 / 610 V2 2-pole 3-phase electric motor with Star / Delta starting for all other machines. Stepless capacity control, 50 100% for each compressor. Crankcase heater. Terminal box with IP54 enclosure class. Rubber supports. EVAPORATOR Shell and tube evaporator optimized for R134a refrigerant. Tubes with a helical rifled internal surface. Intermediate baffles positioned to ensure optimum speed of the fluid and low pressure drops. Single circuit on water side and independent circuits, one for each compressor, on refrigerant side. Shell, header, tube sheets, made of carbon steel, tubes in Cu. Anticondensate insulation made of polyurethane. Temperature sensors on water inlet and outlet. Threaded hydraulic connections or with grooved end arranged for flexible joint (the flexible joint and the adapter pipe are optional accessories). CONDENSER One condenser for each refrigerant circuit: Shell and tube condenser optimized for R134a refrigerant. Shell, header, tube sheets made of carbon steel, tubes in Cu. Insulation made of polyurethane. Temperature sensor on water outlet. Threaded hydraulic connections or with grooved end arranged for flexible joint (the flexible joint and the adapter pipe are optional accessories). REFRIGERANT CIRCUIT Components for each refrigerant circuit: Electronic expansion valve that allows high performance and system efficiency thanks to a timely and accurate response to changes in temperature and pressure. Sight glass. Filter dryer on liquid line. Service valves on liquid line. Service valves on gas discharge. Safety valve on low pressure side. Safety valve on high pressure side. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure and oil pressure. High pressure safety switch with manual reset. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R134a refrigerant charge. RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a 5

ELECTRICALPANEL In accordance with EN60204-1 norms, suitable for indoor installation, complete with: Main switch with door lock safety. Fuses for each compressors. Contactors for each compressors (2 contactors for Part-Winding start system 3 contactors for Star / Delta start system). Compressor Part-Winding start system for model 410 V2 / 460 V2 / 510 V2 / 540 V2 / 610 V2 Compressor Star / Delta start system for all other machines. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Summer / Winter working mode selector. Power supply: 400/3/50. CONTROL SYSTEM MP.COM microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Main components hour-meter. - Integrated Data logger function for the recording of events and alarms. - Non-volatile Flash memory for data storage. - Menu with protection password. - Driver for the additional module. - Additional module 1 for condenser water outlet temperature sensor. HYDRAULIC CONNECTIONS OF HEAT EXCHANGERS Heat exchangers threaded hydraulic connections ISO 228/1 G M, available up to a diameter of 3" included. Pipes threaded hydraulic connections ISO 7/1 R, available up to a diameter of 3" included. The hydraulic connections with flange (FL) are not supplied with counter flange. The hydraulic connections with grooved end are not supplied with flexible joint (optional accessory). 6 RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a

OPTIONAL ACCESSORIES The descriptions of these optional accessories can be found in Chapter ACCESSORIES Brine A kit for chilled water production up to 6 C, Brine B kit for chilled water production lower than 6 C. WARNING With BRINE Kit it is mandatory to use antifreeze mixture. Refer to the paragraph ANTIFREEZE SOLUTION. The use of antifreeze mixtures causes a reduction of the machine performance, Please refer to the RC WORLD electronic catalogue to obtain the effective performance. Partial heat recovery system. OTHER OPTIONAL ACCESSORIES Chilled water safety flow switch. Hydraulic connections of the evaporator and the condensers: - Flexible joint with adapter pipe (solder type). - Flexible joint with adapter for flange connection (FL). The counter-flange is not supplied. The optional is not available for unit with threaded hydraulic connections. Compressor thermal protection relay. Power factor capacitor for motor compressor - cos 0,9. Stop valve on compressor suction. Rubber supports - not installed. Compressor soundproof box (For further information please refer to the units acoustic data) MP.COM microprocessor accessories: - Clock card for alarms date and time displaying and storing. - Serial port RCcom, MBUS/JBUS. - Serial port LON. - Serial port BACnet for Ethernet SNMP TCP/IP. - Serial port BACnet for MS/TP. - Serial port for GSM modem. - Data logger for the memorization of the intervened alarms. - Accessories that can be connected to the additional module 1 : o Water flow measurement / Line voltage indication / Line current indication o Compensation / Line voltage indication / Line current indication o Ambient air temperature - Additional module 2 with the following inlets / outlets: INLETS o External alarm 1 o External alarm 2 o External alarm 3 o External alarm 4 OUTLETS o External alarm 1 o External alarm 2 o General alarm 3 o General alarm 2 WARNING RC GROUP reserves the right to determine the compatibility of combinations of accessories required in the order. RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a 7

TECHNICAL DATA MODEL 410 V2 460 V2 510 V2 540 V2 610 V2 700 V2 790 V2 SUMMER WORKING MODE (1) COOLING CAPACITY kw 394 443 494 551 603 656 740 Compressors power input kw 82,5 92,4 103 109 134 144 163 Compressors operating current [OA] A 148 178 195 202 225 250 273 EVAPORATOR Water flow rate m³/h 67,7 76,1 84,7 94,6 103 113 127 Pressure drop kpa 10 16 17 22 24 14 12 CONDENSER Water flow rate m³/h 82,6 92,8 103 114 128 139 156 Pressure drop kpa 10 12 15 1 23 18 22 WINTER WORKING MODE (2) HEATING CAPACITY kw 477 533 598 666 736 830 963 Compressors power input kw 94,8 106 119 128 144 159 182 Compressors operating current [OA] A 244 247 289 295 240 271 304 EVAPORATOR Water flow rate m³/h 65,7 73,4 82,4 92,6 102 115 134 Pressure drop kpa 13 18 19 22 26 8 6 CONDENSER Water flow rate m³/h 67,7 76,1 84,7 94,6 103 113 127 Pressure drop kpa 7 2 1 4 16 16 17 PARTIAL HEAT RECOVERY (3) HEATING CAPACITY kw 49,7 55,5 62,3 70,0 77,0 87,2 101,0 Heat recovery water flow m³/h 8,56 9,57 10,7 12,1 13,3 15 17,5 Heat recovery pressure drop kpa 4,6 4,2 3,7 3,5 3,3 3,4 3,8 COMPRESSORS twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw Quantity n. 2 2 2 2 2 2 2 Maximum current A 205 236 270 288 330 367 414 Starting current A 383 469 630 639 811 544 568 Stepless capacity control 25...100 25...100 25...100 25...100 25...100 25...100 25...100 EVAPORATOR n. 1 1 1 1 1 1 1 Water volume l 149 142 255 255 255 255 237 Max water flow rate m³/h 95 100 127 127 127 127 154 CONDENSER n. 2 2 2 2 2 2 2 Total water volume l 78 78 99 99 99 99 109 Max water flow rate m³/h 98 98 116 116 116 116 170 PARTIAL HEAT RECOVERY EXCHANGERS n. 2 2 2 2 2 2 2 Total water volume l 14,4 14,4 19,2 19,2 19,2 27,0 37,0 Max water flow rate m³/h 37 37 37 37 37 37 37 REFRIGERANT R134a R134a R134a R134a R134a R134a R134a Total refrigerant charge (optional excluded) kg 65 65 155 155 155 155 142 Gas circuits n. 2 2 2 2 2 2 2 POWER SUPPLY V/Ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 ENERGY EFFICIENCY INDEXES EER - Energy Efficiency Ratio 4,78 4,79 4,80 5,06 4,50 4,56 4,54 COP Coefficient of Performance 5,03 5,03 5,03 5,20 5,11 5,22 5,29 ESEER - Eurovent Standard 5,41 5,34 5,25 5,72 5,12 5,19 5,16 IPLV - ARI Standard 550/590 5,72 5,42 5,39 6,04 5,44 5,51 5,49 SOUND LEVEL Average sound pressure level [LPm] (4) db(a) 74,0 74,0 74,0 74,0 79,0 79,0 79,0 Sound power level [Lw] (5) db(a) 91,8 91,8 91,8 91,8 96,8 96,8 97,6 DIMENSIONS Length mm 3359,5 3359,5 3349,5 3349,5 3435 3514 3894 Width mm 975 975 1013 1013 1007 1060 1210 Height mm 1498 1498 1618 1618 1740 1780 1888 NET WEIGHT kg 3237 3268 3498 3498 3590 3720 3967 HYDRAULIC CONNECTIONS EVAPORATOR Inlet/outlet (OD) (6) Ø mm 168,3 168,3 168,3 168,3 168,3 168,3 219,1 CONDENSER Inlet/outlet (ISO228/1) n x Ø 2 x 3" 2 x 3" 2 x 3" 2 x 3" 2 x 3" 2 x 3" 2 x 3" Inlet/outlet (OD) (6) n x Ømm -- -- -- -- -- -- -- PARTIAL HEAT RECOVERY Inlet/outlet (ISO228/1) n x Ø 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 1. Gross value - Referred to chilled water temperature 12/7 C; water to the condenser 30/35 C. 2. Gross value - Referred to chilled water temperature 15/10 C; water outlet to the condenser 45 C. 3. Gross value - Referred to chilled water temperature 12/7 C; water to the condenser 30/35 C and hot water temperature 40/45 C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 2. 6. With flexible joint predisposition. 8 RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a

TECHNICAL DATA MODEL 940 V2 1050 V2 1110 V2 1140 V2 1310 V2 1460 V2 1610 V2 SUMMER WORKING MODE (1) COOLING CAPACITY kw 880 973 1031 1073 1224 1365 1505 Compressors power input kw 196 218 228 236 269 297 335 Compressors operating current [OA] A 299 349 362 385 463 516 567 EVAPORATOR Water flow rate m³/h 151 167 177 184 210 234 258 Pressure drop kpa 17 24 23 21 24 33 41 CONDENSER Water flow rate m³/h 186 206 218 227 259 288 319 Pressure drop kpa 17 18 23 20 16 17 20 WINTER WORKING MODE (2) HEATING CAPACITY kw 1115 1257 1346 1412 1569 1766 1976 Compressors power input kw 215 240 255 271 298 333 378 Compressors operating current [OA] A 335 386 406 441 516 575 642 EVAPORATOR Water flow rate m³/h 155 175 187 196 218 246 275 Pressure drop kpa 13 25 21 22 20 35 43 CONDENSER Water flow rate m³/h 151 167 177 184 210 234 258 Pressure drop kpa 13 12 15 13 11 12 14 PARTIAL HEAT RECOVERY (3) HEATING CAPACITY kw 117,0 132,0 142,0 148,0 165,0 186,0 208,0 Heat recovery water flow m³/h 20,2 22,8 24,4 25,6 28,5 32,1 35,8 Heat recovery pressure drop kpa 4,6 5,2 7,2 8,3 10,9 13,5 16,5 COMPRESSORS twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw twin-screw Quantity n. 2 2 2 2 2 2 2 Maximum current A 474 536 567 615 710 798 896 Starting current A 611 721 827 903 1058 1182 1324 Stepless capacity control 25...100 25...100 25...100 25...100 25...100 25...100 25...100 EVAPORATOR n. 1 1 1 1 1 1 1 Water volume l 229 276 276 370 368 357 431 Max water flow rate m³/h 172 172 172 220 245 267 312 CONDENSER n. 2 2 2 2 2 2 2 Total water volume l 109 135 135 155 171 182 210 Max water flow rate m³/h 186 216 216 240 260 284 320 PARTIAL HEAT RECOVERY EXCHANGERS n. 2 2 2 2 2 2 2 Total water volume l 32,0 34,0 34,0 39,0 39,0 54,0 54,0 Max water flow rate m³/h 67 67 67 67 67 67 67 REFRIGERANT R134a R134a R134a R134a R134a R134a R134a Total refrigerant charge (optional excluded) kg 136 130 130 121 180 176 172 Gas circuits n. 2 2 2 2 2 2 2 POWER SUPPLY V/Ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 ENERGY EFFICIENCY INDEXES EER - Energy Efficiency Ratio 4,49 4,46 4,52 4,55 4,55 4,60 4,49 COP Coefficient of Performance 5,19 5,24 5,28 5,21 5,27 5,30 5,23 ESEER - Eurovent Standard 5,08 5,06 5,16 5,04 5,04 5,10 4,99 IPLV - ARI Standard 550/590 5,37 5,34 5,46 5,17 5,18 5,24 5,12 SOUND LEVEL Average sound pressure level [LPm] (4) db(a) 82,0 82,0 82,0 82,0 82,0 84,0 84,0 Sound power level [Lw] (5) db(a) 100,6 100,6 101,2 101,2 101,2 103,6 103,6 DIMENSIONS Length mm 3894 3894 3932,5 3874 4273 4273 4352 Width mm 1210 1210 1218 1287 1284 1284 1284 Height mm 1888 1888 1890 1975 2084 2084 2108 NET WEIGHT kg 4071 4835 4949 5031 5549 6407 6537 HYDRAULIC CONNECTIONS EVAPORATOR Inlet/outlet (OD) (6) Ø mm 219,1 219,1 219,1 219,1 219,1 273 273 CONDENSER Inlet/outlet (ISO228/1) n x Ø 2 x 3" 2 x 3" 2 x 3" -- -- -- -- Inlet/outlet (OD) (6) n x Ømm -- -- -- 2 x 114,3 2 x 114,3 2 x 114,3 2 x 141,3 PARTIAL HEAT RECOVERY Inlet/outlet (ISO228/1) n x Ø 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 2 x 2" 1. Gross value - Referred to chilled water temperature 12/7 C; water to the condenser 30/35 C. 2. Gross value - Referred to chilled water temperature 15/10 C; water outlet to the condenser 45 C. 3. Gross value - Referred to chilled water temperature 12/7 C; water to the condenser 30/35 C and hot water temperature 40/45 C. 4. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 5. Sound power level [Lw] according to ISO EN 9614 2. 6. With flexible joint predisposition. RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a 9

ACOUSTIC DATA MODEL 410 V2 460 V2 510 V2 540 V2 610 V2 700 V2 790 V2 Sound power level [Lw] (1) db(a) 91,8 91,8 91,8 96,8 96,8 97,6 100,6 Sound pressure level at [LPm] 1m (2) db(a) 74,0 74,0 74,0 79,0 79,0 79,0 82,0 MODEL 940 V2 1050 V2 1110 V2 1140 V2 1310 V2 1460 V2 1610 V2 Sound power level [Lw] (1) db(a) 100,6 101,2 101,2 101,2 103,6 103,6 103,6 Sound pressure level at [LPm] 1m (2) db(a) 82,0 82,0 82,0 82,0 84,0 84,0 84,0 FRIGO SCREW CLA WITH SOUNDPROOF BOX MODEL 410 V2 460 V2 510 V2 540 V2 610 V2 700 V2 790 V2 Sound power level [Lw] (1) db(a) 85,8 85,8 85,8 90,8 90,8 91,6 94,6 Sound pressure level at [LPm] 1m (2) db(a) 68,0 68,0 68,0 73,0 73,0 73,0 76,0 MODEL 940 V2 1050 V2 1110 V2 1140 V2 1310 V2 1460 V2 1610 V2 Sound power level [Lw] (1) db(a) 94,6 95,2 95,2 95,2 97,6 97,6 97,6 Sound pressure level at [LPm] 1m (2) db(a) 76,0 76,0 76,0 76,0 78,0 78,0 78,0 1. Sound power level according to ISO EN 9614 2 2. Average sound pressure level 1m far according to ISO EN 3744 IMPORTANT For further information about units acoustic data, please refer to The Noise bulletin of RC GROUP technical literature. ELECTRIC DATA MAXIMUM ELECTRIC ABSORPTION CALCULATION This chapter is showing the maximum electrical absorption calculation of unit (A), corresponding to extreme working conditions. The involved components are the following: - Compressors electric motor The electrical data of the various components are indicated in the relative technical data sheets. Calculation for FRIGO SCREW WP 410 V2: MAXIMUM ELECTRIC ABSORPTION [FLA] - Compressors A 205 Maximum electric absorption A 205 10 RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a

MP.COM: MICROPROCESSOR CONTROL SYSTEM The MP.COM microprocessor control system is equipped with 8 keys terminal and back lighted graphic display on which all information in different languages or easily identifiable symbols are displayed. The system disposes of a flash memory that preserves the information even in absence of power supply. M P. C O M g r a p h i c i n t e r f a c e 13:35 - S - nn - 21/01/07 To Ev 07.0 C Ti 12.5 C A L L A R M I 1 2 3 4 5 6 7 8 KEYBOARD FUNCTIONS KEY 1 KEY 2 KEY 3 KEY 4 KEY 5 KEY 6 KEY 7 KEY 8 Switches on/off the unit. Stops the alarm acoustical signal and displays the intervened alarm. Accedes to the parameters of possible units connected in LAN network. LAN connection with 3 wires without additional accessories. It is possible to connect in network different capacity units and with different number of compressors. Home key displays the main screen. Accedes to control and visualization menus as: Unit working status Set-points Alarms reset (protected by password) Service parameters setting (protected by password) Intervened alarms history Setting for main components manual operation (protected by password) Date and time setting Setting of communication system for SMS messages dispatch Scroll the pages inside each menu and decreases the displayed value Scroll the pages inside each menu and increases the displayed value Shift the cursor inside each menu and confirm a parameter insertion RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a 11

MP.COM: MICROPROCESSOR CONTROL SYSTEM REMOTE CONTROLS/ALARMS MP.COM MICROPROCESSOR CONTROL INLETS External enabling Cooling enabling Cooling set-point changeover (xk1 - xk2) Compressor 1 enabling Compressor 2 enabling OUTLETS General alarm 1 ADDITIONAL MODULE 1 Ambient air probe Hot water outlet probe Water flow measurement/voltage/current line Set point compensation ADDITIONAL MODULE 2 (on request) INLETS External alarm 1 External alarm 2 External alarm 3 External alarm 4 OUTLETS External alarm 1 External alarm 2 External alarm 3 General alarm 2 (programmable) remote controls/alarms voltage free controls/alarms 12 RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a

OPTIONAL ACCESSORIES BRINE A KIT The accessory allows the production of glycol solution leaving the machine down to a temperature of -6 C. The kit includes: Set of the working parameters. Compressor oil cooling system through liquid injection. OPTIONAL ACCESSORIES BRINE B KIT The accessory allows the production of glycol solution leaving the machine lower than 6 C. The kit includes: Set of the working parameters. Evaporator in special execution for low temperature. Special thermal insulation of the evaporator. Compressor oil cooling system with welded plate heat exchangers oil / refrigerant liquid. WARNING: With BRINE Kit it is mandatory to use antifreeze mixture. Refer to the paragraph ANTIFREEZE SOLUTION. The use of antifreeze mixtures causes a reduction of the machine performance, Please refer to the RC WORLD electronic catalogue to obtain the effective performance. RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a 13

OPTIONAL ACCESSORIES - PARTIAL HEAT RECOVERY SYSTEM The partial heat recovery exchangers are installed on every refrigerant circuit of the machine before the main condenser. The system is not regulated and the control is ON-OFF type. The heat recovery system s operation is subject to the supply demand of cooling capacity. The system includes: Copper brazed plate type heat exchanger with cover plates, plates and connections in AISI 316 stainless steel. Anticondensate insulation made of polyurethane. The heating capacity which is supplied depends on the kind of refrigerant gas which is used and working temperatures. The heat exchangers can produce hot water up to the maximum temperature of 70 C and according to the working conditions of the unit. PARTIAL HEAT RECOVERY HEAT RECOVERY HYDRAULIC CIRCUIT C-IN C-OUT SC1 A1 SC2 A2 RU1 COM1 RU2 COM2 SUCTION LINES LIQUID LINES COM Compressor RU Valve SC Partial heat recovery exchanger A Main condenser C-IN Water inlet collector C-OUT Water outlet collector 14 RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a

UNIT DRAWINGS Dimensions in mm FRIGO SCREW WP 410 V2 / 460 V2 RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a 15

UNIT DRAWINGS Dimensions in mm FRIGO SCREW WP 510 V2 / 540 V2 16 RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a

UNIT DRAWINGS Dimensions in mm FRIGO SCREW WP 610 V2 RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a 17

UNIT DRAWINGS Dimensions in mm FRIGO SCREW WP 700 V2 18 RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a

UNIT DRAWINGS Dimensions in mm FRIGO SCREW WP 790 V2 / 940 V2 / 1050 V2 RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a 19

UNIT DRAWINGS Dimensions in mm FRIGO SCREW WP 1110 V2 20 RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a

UNIT DRAWINGS Dimensions in mm FRIGO SCREW WP 1140 V2 RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a 21

UNIT DRAWINGS Dimensions in mm FRIGO SCREW WP 1310 V2 / 1460 V2 22 RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a

UNIT DRAWINGS Dimensions in mm FRIGO SCREW WP 1610 V2 RC GROUP S.p.A. T_FRGSCRWP_0913_GB R134a 23

The continuous improvement of products may imply changes in the data shown in this catalogue. RC GROUP S.p.A. Via Roma, 5 27010 Valle Salimbene (PV), Italy www.rcgroup.it Tel. +39 (0) 382 433 811 Fax +39 (0) 382 587 148 T_FRGSCRWP_0913_GB RC Group S.p.A. is a company of