GENERAL CATALOGUE July I talian technology and quality. Heat Pumps. Indirect Cylinders Electric Water Heaters.

Similar documents
Electric Water Heaters. The STRENGTHS of the product range in detail:

Heat Accumulation. thermal stores hot water storage tanks. Energy-saving solutions

Aqua 1 plus Air-water heat pumps for domestic hot water production

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

VERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

SHERPA. Air-water split heat pump. COP > 4 ACS a 60 C

ECO HOT WATER Air-water heat pump for domestic hot water with integrated solar panels and remote control via App GB 02. Ecoenergy.

STORAGE WATER HEATERS

DOMESTIC WATER HEAT PUMPS

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

Industrial and collective. With coil exchanger. Technical data. Initial heat-up. surface area. Exchanger. Exchanger capacity.

Water Heaters and. Storage Vessels. Indirect Water Heaters (mains water systems)

LZT LZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. A + A + VERSIONS ACCESSORIES

NUOS RANGE HEAT PUMP WATER HEATERS

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

RENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05

Air Cooled Scroll Chiller

Industrial cooling solutions

Flamco. Water heaters, storage tanks and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS WATER HEATERS, STORAGE TANKS

Personalized comfort for offices and shopping malls RANGE OPERATING LIMITS

BF1 GLASSLINED CYLINDERS WITH REMOVABLE STAINLESS STEEL HEAT EXCHANGER ( LITRES)

AWR MTD2 XE. Versions

IDU22C, 22C1, 37C, 37C1, 55C, 75C

TERMO Combi Cylinder TECHNICAL INFORMATION

Refrigerated Air Dryers

Refrigerated Air Dryers

S SOLAR RANGE

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

REMKO HYBRID HEAT PUMPS

Refrigerated Air Dryer

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

BF2 GLASSLINED CYLINDERS WITH TWO REMOVABLE STAINLESS STEEL HEAT EXCHANGERS ( LITRES)

pyxis pyxisa NEW rcgroupairconditioning

EXPLORER HEAT PUMP WATER HEATER. A+ in READY Smart heat pump

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

LZT High efficiency air to water heat pumps with E.V.I. compressors

For latest prices and delivery to your door visit MyTub Ltd

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

HEAT PUMP Heat pump air conditioner. Thanks to this feature you can replace traditional heating in intermediate seasons or support it.

pyxis u pyxis ua NEW rcgroupairconditioning

ECOplus Solar Cylinder

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

D O M E S T I C Solar Thermal

Solar Thermal Energy

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual

unico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning

Technical data. Danfoss DHP-H. Extra and hotter hot water. Extra large integrated hot water tank. Can reduce heating costs by more than 50 percent.

New Panasonic Aquarea DHW. Domestic Hot Water Tanks

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

CRIMSON & CRIMSON MAX

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

SHERPA. Air-water split heat pump. COP > 4 DHW 60 C

1 VICTRIX ZEUS Superior kw I features

Knight & Charger Water Heaters

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

Installation, Operating and Servicing Instructions

High performances NEW ELECTRIC STORAGE WATER HEATERS

Smart Collection. April 2012

Sweden s leading air source heat pump

Refrigerated Air Dryer

Since 1960 we have produced your hot water

PYXIS U PYXIS U. rcgroupairconditioning

REMKO Comfort-WP The versatile heat pump

INDIRECT WATER HEATERS

HT V2 HT Split

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

Refrigerated Air Dryers

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

ACCUMULATION OF EUROPEAN CLASS

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG.

Make value of the waste energy from your cooling units and heat water for free

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

WATER HEATERS Range of Products. Everyday comfort.

Specification data Topvex. Rotating or Cross flow heat exchanger.

Installation and Operating Instructions. Hot water heat pump

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

EVI Scroll Air To Water Heat Pumps

Advance Split

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

October Solar Thermal

HOT TAP WATER EXCHANGER with solar pump-group ENSOL IT INSTALLATION AND OPERATION MANUAL WARRANTY CARD

Installation and Operation Manual IDRA N DS. Solar solar storage cylinder. Installation and Operation Manual

WATER HEATERS EN - flyer 03/z/2018 Made in Poland

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Installation and Operation Manual IDRA N DS. Solar solar storage cylinder. Installation and Operation Manual

Condensing, pre-mixed, wall-hung gas boilers with water tank

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

Installation, Operating and Servicing Instructions

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZA High efficiency air to water heat pumps with HP compressor

Introduction...from 3 to 4 Tanks for the production and storage of DHW. Domestic use....from to 8 Tanks for the production and storage of DHW. Industr

Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

=Classic range= Classic range technologies. Magnesium anode. Sheathed heating element

v SELECTION GUIDELINES

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Transcription:

I talian technology and quality NR TOU Heat Pumps as Water Heaters Indirect ylinders lectric Water Heaters uffer ylinders Wood-fired Water Heaters

ontents HT PUMPS Page 4 utura utura: 80-100 6 utura Termo utura: 100 TS 7 HP HP:180-300 8 HP 1/2 oil HP: 180 W- 300 W / 9 utura loor Standing utura: 200-250 -300 11 utura 1 oil utura: 200-250 -300 W 12 utura 2 oil utura: 250-300 13 utura Inox loor Standing utura: 210-270-315 X 15 utura Inox 1 oil utura: 210-270-315 WX 16 utura Inox 2 oil utura: 270-315 X 17 INIRT YINRS Page 18 Undermount ISSWT: 120-160 20 Vertical Wall-Hung V/TS: 80 200 X/SX 21 I ON ISSWH: 300-400-500 22 Multiposition MS: 120 300 23 ree Standing One ISSW: 120 2000 24 ree Standing Two ISS: 200 2000 26 ree Standing One ouble Wound ISSWP : 300 1000 28 ree Standing Two ouble Wound ISSP: 500 1000 30 INIRT YINRS INOX Page 32 ree Standing One Inox ISSWX: 120 500 34 ree Standing Two Inox ISSX: 200 500 36 ree Standing One e Two High Storage Inox ISSWX: 800-1000 ISSX: 800-1000 38 UR YINRS Page 40 PH SO (without inspection hatch) ISPHSO: 200 2000 42 PHW (with one pipe coil) / PH (with two pipe coil) ISPHSW: 600 2000 ISPHS : 600 2000 44 Pipe in Tanks PTS PTSW: 600 2000 PTS: 600 2000 hilled water buffer cylinders ISSR:200 2000 48 46 2

S WTR HTRS Page 49 Natural raught Wall-Hung N: 50 120 50 Natural raught loor Standing /P: 150-200 51 Natural raught loor Standing Medium Size /PR e /PR : 300-500 52 Natural raught loor Standing ig Size /P e /P : 600 1500 53 an lue loor Standing T : 220-300-400 54 TRI WTR HTRS WOO-IR WTR HTRS SSORIS Page 55 Rapidi / Rapidi S Pony :10-15-30 - Pony 10/15/30/S 56 Standard series V and V V 30 200 and V: 30 100 57 Standard S V:50 200 S 58 Standard Termo V/T: 50-80-100 and V/T 120 200 59 Standard with solar heat exchanger V/TS: 80 200 X/SX 60 Horizontal / Horizontal Termo O: 50 200 - O/T 80-100 61 Interline ISS : 120 1000 62 Interline Inox ISSX : 120 500 ISSX : 800-1000 Page 64 loor Standing - - /T 65 Page 66 for electric water heater, indirect and buffer cylinders 66 for heat pumps 68 for gas water heaters 69 63 NR NOTS Page 71 3

Heat Pumps The strengths The features that make this system worthwhile are multiple, but the most obvious advantage is that it is an intrinsically efficient system. It has direct repercussions on the amortisation of the installation cost and on the consumer s utility bills too. Moreover, using a heat pump enables the exploitation of portions of energy which would otherwise be wasted (such as in installations in boiler rooms). astly, this system also provides an easy and convenient integration with other renewable energy sources (solar panels, wood-fired boilers, etc.). Heat pumps are ideally installed in cellars or damp rooms because the humidity in the air is removed during (dehumidifying effect). The Systems The heart of the System is an indirect cylinder with a built-in heat pump that enables the simultaneous or selective use of up to four different energy sources: 1) thermal energy; 2) electricity; 3) solar power; 4) environmental energy. The heat pump is designed to transfer heat from a body at a lower temperature to another body at a higher temperature. This process is the opposite of what happens in nature, and is due to the fact that electricity is supplied to the appliance that heat pumps. The principle of the heat pump is a thermodynamic cycle opposite to refrigeration. The efficiency of a heat pump is represented by its performance coefficient OP, which is the ratio of the heat output yielded to the electrical power utilised. Safety The products are insulated using polyurethane foam which has been certified with a fire resistance class 2 according to IN 4102 (self-extinguishing). 4

The STRNTHS of the product range in detail: Operating principle The heat pump comprises a closed circuit made up of a compressor, a condenser, a lamination valve and an evaporator through which the heat transfer fluid flows. The thermodynamic cycle the fluid experiences consists in an adiabatic compression, a condensation phase, an expansion phase and also evaporation. uring compression, the pressure and temperature of the fluid rise, during the second stage the fluid flows through a heat exchanger (condenser) where it comes into contact with domestic water, to which it yields heat. uring the third stage, the fluid flows through an expansion valve (lamination process) and its pressure and temperature consequently drop. uring the last stage, referred to as evaporation, the fluid switches from its liquid state to gas: the coolant is at very low temperatures, which enable it to absorb heat from the external heat transfer fluid. So during the of the heat pump, the following occurs: electricity is consumed in the compressor, heat is absorbed from the external environment (evaporator) and heat is yielded in the condenser to the liquid that needs to be heated. The advantage of a heat pump lies in the fact that more energy is supplied in the form of heat than the electricity required for its. VPORTOR bsorption of heat from the outside 2/3 of energy TRIITY SUPPY 1/3 of energy MINTION VV ONNSR Yielding of heat to the domestic water 3/3 of energy Product Range Styleboiler heat pumps are available in the following versions: - Wall-hung, glass-lined steel (utura models 80/100) - Wall-hung, glass-lined steel with single coil (utura model 100TS) - loor standing glass-lined steel (utura models 200/250/300 and HP 180/300) - loor standing stainless steel (utura models 210/270/315 X) - loor standing glass-lined steel with single coil (utura models 200/250/300 W and HP 180/300 W) - loor standing stainless steel with single coil (utura models 210/270/315 WX) - loor standing glass-lined steel with double coil (utura models 200/250/300 and HP 180/300 ) - loor standing stainless steel with double coil (utura models 210/270/315 X) The wide range allows you to always find the right product for different installation needs. 5

HT PUMPS wall-hung utura SRIS 80-100 ompact system for heating sanitary water by using an air-to-water heat pump. The system utilises renewable energy. It is one of the most interesting products to be used for decreasing the fuel consumption and protecting the environment. Thanks to its small dimensions, equal to a normal water heater, and to its easy installation, the new heat pump (from 80 to 100) is intended or domestic use. Just plug it in, like a normal water heater, and it is ready. Steel tank, glass-lined using the flow-coating method (850 ) orrosion-proof magnesium anode xternal casing made of sheet metal coated with (white) epoxy powder paint and H-free, 37 mm average rigid polyurethane (PU) insulation layer located in the lower part rackets for wall-mounting 1,2 kw 230V~ integrated electric heating element lectronic control panel with display indicating temperature, indicator light for heat pump and electric resistance. Switch to activate the different modes of : Turbo, ath, omfort. unction anti-legionella cological refr rant fluid R134a Rotary compressor for maximum noiseless xial fan Powerful fin type evaporator Packaging100% recyclable Type apacity ode Power supply Type oefficient of performance temperature (heat pump only) Refrigerant fluid/ average load temperature (with electric heating element) verage absorption (Heat pump only) Heating Time * lectric heating element (water) pressure 1 / 2 lectric heating element (air heating) nominal absorption / V~/Hz/ -/kg kw kw kw kw utura 080 80 185673 230/50/16 R134a/0,28 0,30 1,20 0,90 2,40 utura 100 100 185674 230/50/16 R134a/0,28 0,30 1,20 0,90 2,40 OP min MPa Kg. - mm mm utura 080 3 56 65 255 0,6/1,2 50 ½ 1.142 392 utura 100 3 56 65 322 0,6/1,2 56 ½ 1.355 605 * Note: Heating times to reach 56 with the sole use of heat pump, ambient temperature of 20 and water temperature at 15 1 pressure, 2 pressure test according to N 12897 P.4.4.1 480 470 112 431 60 206 544 Same of traditional water heaters asy installation ucting and masonry work not required Save up to 70% of electricity 100 6

wall-hung utura Termo SRIS 100 TS ompact system for heating sanitary water by using an air-to-water heat pump. The system utilises renewable energy. It is one of the most interesting products to be used for decreasing the fuel consumption and protecting the environment. Thanks to its small dimensions, equal to a normal water heater, and to its easy installation, the new heat pump (from 80 to 100) is intended or domestic use. Just plug it in, like a normal water heater, and it is ready. HT PUMPS Steel tank, glass-lined using the flow-coating method (850 ) orrosion-proof magnesium anode xternal casing made of sheet metal coated with (white) epoxy powder paint and H-free, 37 mm average rigid polyurethane (PU) insulation layer located in the lower part rackets for wall-mounting 1,2 kw 230V~ integrated electric heating element lectronic control panel with display indicating temperature, indicator light for heat pump and electric resistance. Switch to activate the different modes of : Turbo, ath, omfort. unction anti-legionella Steel coil for connecting to the heating system cological refr rant fluid R134a Rotary compressor for maximum noiseless xial fan Powerful fin type evaporator Packaging100% recyclable new Type apacity ode Power supply Refrigerant fluid/ average load verage absorption (Heat pump only) lectric heating element (water) lectric heating element (air heating) nominal absorption / V~/Hz/ -/kg kw kw kw kw utura 100 TS 100 185885 230/50/16 R134a/0,28 0,30 1,20 0,90 2,40 Type oefficient of performance Maximum temperature (heat pump only) temperature (with electric heating element) utura 100 TS 3 56 65 320 0,6/1,2 0,45 64 ½ 1.355 605 HP * Note: Heating times to reach 56 with the sole use of heat pump, ambient temperature of 20 and water temperature at 15 1 pressure, 2 pressure test according to N 12897 P.4.4.1 Heating Time * pressure 1 / 2 Heat xchange surface OP min MPa m 2 Kg. --PV-PR mm mm 480 ø 470 112 303 338 431 100 544 60 206 lectronic control panel with display indicating temperature HP T 7

HT PUMPS HP SRIS HP 180-300 omestic water heating system with air-water heat pump. The system envisages the use of renewable energy and the possible integration with other energy sources such as electricity. Recommended for domestic and collective use. Steel tank, glass-lined using the flow-coating method (850 ) Ø 134 mm front inspection hatch integrated with tinned copper condenser orrosion-proof magnesium anode located on the rear and H-free very thick polyurethane (PU) foam insulation layer xternal soft plastic coating (PV) djustable feet for floor standing nvironmentally-friendly gas R 134a 1.5 kw 230V~ electric heating element (INOX Incoloy 800) ontrol panel complete with switch with indicator light for heat pump and heating element, regulation thermostat, thermometer and signal indicators High and low pressure safety devices ompressor for super silent 650 m3/h axial fan stand alone Type w SVW SSI Type apacity ode oefficient of performance Power supply Range of hot water temp. setting Refrigerant fluid/ average load Range of use Maximum noise level verage absorption (Heat pump only) * Temperature anti-legionella cycle nominal absorption pressure 1 / 2 Power output (heat pump only) ** lectric heating element (integration) Recirculation fittings Maximum power output / V~/Hz/ -/kg kw kw kw kw kw HP 180 180 185676 230/50/16 R134a/0,85 0,62 2,12 1,91 1,50 3,41 HP 300 300 185677 230/50/16 R134a/0,85 0,62 2,12 1,91 1,50 3,41 Heat loss N 12897 OP d () MPa kg --PV-PR Z kwh/24h HP 180 3,1 29 56 8 35 61 65 0,6/1,2 95 Rp 1 Rp 1 1,8 HP 300 3,2 29 56 8 35 61 65 0,6/1,2 109 Rp 1 Rp 1 2,3 * ata comliant with N 2553 (WPZ 0020407 Wärmepumpentestzentrum NT WS Huchs) 1 pressure, 2 pressure test according to N 12897 P.4.4.1 ccessories on page 69 650 713 1412 Z 612 922 142 HP 180 HP 180 HP 300 HP 300 8

stand alone HP 1 or 2 oil SRIS HP 180W-300 W/ omestic water heating system with air-water heat pump. The system envisages the use of renewable energy and the possible integration with other energy sources such as electricity, thermal energy and solar power. Recommended for domestic and collective use. Steel tank, glass-lined using the flow-coating method (850 ) Ø 134 mm front inspection hatch integrated with tinned copper condenser orrosion-proof magnesium anode located on the rear Single coil (for W version) and double coil (for version), optimised for maximum heat exchange and minimum limescale build-up Sensor fittings (one for W version) (two for version) and H-free very thick polyurethane (PU) foam insulation layer xternal soft plastic coating (PV) nvironmentally-friendly gas R 134a 1.5 kw 230V~ electric heating element (INOX Incoloy 800) ontrol panel complete with switch with indicator light for heat pump and heating element, regulation thermostat, thermometer and signal indicators High and low pressure safety devices ompressor for super silent 650 m3/h axial fan ccessories on page 69 Type apacity ode Type Range of hot water temp. setting Power supply Range of use Refrigerant fluid/ average load Maximum noise level verage absorption (Heat pump only) * Temperature anti-legionella cycle pressure 1 / 2 nominal absorption HP 300 W Power output (heat pump only) ** oil surface bot. / top Heat output ( T 35 K) ** HT PUMPS HP 300 W/ lectric heating element (integration) oefficient of performance Recirculation fittings Maximum power output / V~/Hz/ /kg kw kw kw kw kw HP 180 W 180 185886 230/50/16 R134a/0,85 0,62 2,12 1,91 1,50 3,41 HP 300 W 300 185678 230/50/16 R134a/0,85 0,62 2,12 1,91 1,50 3,41 HP 300 300 185679 230/50/16 R134a/0,85 0,62 2,12 1,91 1,50 3,41 Heat loss N 12897 OP d () MPa kg m 2 kw -PV-PR Z kwh/24h HP 180 W 3,1 29 56 8 35 61 65 0,6/1,2 106 0,65 22 Rp 1 Rp 1 1,9 HP 300 W 3,2 29 56 8 35 61 65 0,6/1,2 130 1,30 37 Rp 1 Rp 1 2,5 HP 300 3,1 29 56 8 35 61 65 0,6/1,2 145 1,30/0,80 37/26 Rp 1 Rp 1 2,7 * ata comliant with N 2553 (WPZ 0020407 Wärmepumpentestzentrum NT WS Huchs) ** primary circuit temperature 80, Secondary circuit temperature 10/45 1 pressure, 2 pressure test according to N 12897 P.4.4.1 w SVW SSI 650 713 1412 PV Z 922 PR 142 302 632 532 HP 180 W HP 180 W HP 300 W/ HP 300 HP 300 W 9

lass ined Heat Pumps 10

stand alone HT PUMPS utura loor Standing SRIS 200-250-300 Water heating system with air-source heat pump. The system envisages the use of renewable energy. Steel tank, glass-lined using the flow-coating method (850 ) Ø 134 mm frontal inspection hatch orrosion-proof magnesium anode located on the rear and H-free very thick polyurethane (PU) foam insulation layer xternal plastic coating (PV), gray Pantone 403 Heat pump condenser coil wrapped outside the tank to avoid any contact between as and domestic hot water. djustable feet for floor standing nvironmentally-friendly gas R 134a Rotary compressor to limit the sound level 1.5 kw 230V~ electric heating element (INOX Incoloy 800) rgonomic side handles Pressure safety switch ir supply and exhaust ducting allowed lexible programming Type apacity ode Power supply Refrigerant fluid/ average load verage absorption (Heat pump only) * nominal absorption 650 Heating time (only heat pump) 3 lectric heating element (integration) Heat loss N 12897 / V~/Hz/ -/kg kw kw min kw kwh/24h utura 200 200 185792 230/50/16 R134a/0,95 0,90 2,40 218 1,50 1,84 utura 250 250 185794 230/50/16 R134a/0,95 0,90 2,40 270 1,50 2,30 utura 300 300 185797 230/50/16 R134a/0,95 0,90 2,40 324 1,50 2,71 Type oefficient of performance OP Range of hot water temp. heating Range of use noise level Temperature anti-legionella cycle pressure 1 / 2 Recirculation fittings Number of sensors N 255-3 N 16147 d () MPa kg - Z mm mm mm mm utura 200 3,6 2,98 38 60-7 43 48 65 0,6/1,2 105 Rp 1 Rp 1 2 1570 142 532 937 utura 250 3,6 2,98 38 60-7 43 48 65 0,6/1,2 112 Rp 1 Rp 1 2 1790 142 817 1152 utura 300 3,6 2,98 38 60-7 43 48 65 0,6/1,2 119 Rp 1 Rp 1 2 2000 142 928 1362 * mbient air 15, humidity 71%, inlet water temp. 15, Outlet water temperature 55. 1 pressure, 2 pressure test according to N 12897 P.4.4.1 3 : Heating time (water temperature 60 ), mbient temp. 20, inlet water temp. 15 ccessories on page 69 713 ø ST. 195 ø INT. 186 706 ±2 ~ Z 45 11

HT PUMPS stand alone Type apacity ode Power supply Refrigerant fluid/ average load * mbient air 15, humidity 71%, inlet water temp. 15, Outlet water temperature 55. ** Primary temperature 80 / Secondary temp. 10 45. 1 pressure, 2 pressure test according to N 12897 P.4.4.1 3 Heating time (water temperature 60 ), mbient temp. 20, inlet water temp. 15 verage absorption (Heat pump only) * nominal absorption 650 Heating time (only heat pump) 3 lectric heating element (integration) Heat loss N 12897 / V~/Hz/ -/kg kw kw min kw kwh/24h utura 200 W 200 185793 230/50/16 R134a/0,95 0,90 2,40 215 1,50 1,84 utura 250 W 250 185795 230/50/16 R134a/0,95 0,90 2,40 268 1,50 2,30 utura 300 W 300 185798 230/50/16 R134a/0,95 0,90 2,40 335 1,50 2,71 Type oefficient of performance OP Range of hot water temp. setting Range of use Maximum noise level utura loor Standing 1 oil SRIS 200-250-300 W Water heating system with air-source heat pump, with single coil version for integration with solar collector, fireplace stove or boiler with further advantage in terms of efficiency and comfort. The system envisages the use of renewable energy. Steel tank, glass-lined using the flow-coating method (850 ) Ø 134 mm frontal inspection hatch orrosion-proof magnesium anode located on the rear and H-free very thick polyurethane (PU) foam insulation layer Single coil optimised for maximum heat exchange and minimum limescale build-up Two sensor dry wells xternal plastic coating (PV), gray Pantone 403 Heat pump condenser coil wrapped outside the tank to avoid any contact between as and domestic hot water. djustable feet for floor standing nvironmentally-friendly gas R 134a Rotary compressor to limit the sound level 1.5 kw 230V~ electric heating element (INOX Incoloy 800) Pressure safety switch ir supply and exhaust ducting allowed lexible programming Temperature anti-legionella cycle pressure 1 / 2 oil surface Primary Power ** ccessories on page 69 N 255-3 N 16147 d () MPa kg m 2 kw --PV-PR Z utura 200 W 3,6 2,98 38 60-7 43 48 65 0,6/1,2 117 0,80 25,0 Rp 1 Rp 1 utura 250 W 3,6 2,98 38 60-7 43 48 65 0,6/1,2 128 1,10 31,0 Rp 1 Rp 1 utura 300 W 3,6 2,98 38 60-7 43 48 65 0,6/1,2 140 1,30 37,0 Rp 1 Rp 1 Recirculation fittings Type Number of sensor mm mm mm mm mm mm utura 200 W 2 1570 142 352 532 752 937 utura 250 W 2 1790 142 357 817 952 1152 utura 300 W 2 2000 142 342 882 1086 1362 PV Z PR 12

stand alone HT PUMPS utura loor Standing 2 oils SRIS 250-300 Water heating system with air-source heat pump, with second coil, located over the primary coil, to ensure maximum benefit using other heat sources The system envisages the use of renewable energy. Steel tank, glass-lined using the flow-coating method (850 ) Ø 134 mm frontal inspection hatch orrosion-proof magnesium anode located on the rear and H-free very thick polyurethane (PU) foam insulation layer ouble coil optimised for maximum heat exchange and minimum limescale build-up Two sensor dry wells xternal plastic coating (PV), gray Pantone 403 Heat pump condenser coil wrapped outside the tank to avoid any contact between as and domestic hot water. djustable feet for floor standing nvironmentally-friendly gas R 134a Rotary compressor to limit the sound level 1.5 kw 230V~ electric heating element (INOX Incoloy 800) Pressure safety switch ir supply and exhaust ducting allowed lexible programming Type apacity ode Type Number of sensor Power supply mm mm mm mm utura 250 2 1790 142 332 492 utura 300 2 2000 142 342 1062 Type H mm mm mm mm utura 250 732 832 947 1152 utura 300 882 967 1162 1362 Refrigerant fluid/ average load H verage absorption (Heat pump only) * PV2 PR2 PV1 Z PR1 nominal absorption Heating time (only heat pump) 3 H PV2 Z PR2 PV1 PR1 lectric heating element (integration) 650 Heat loss N 12897 / V~/Hz/ -/kg kw kw min kw kwh/24h utura 250 250 185796 230/50/16 R134a/0,95 0,90 2,40 268 1,50 2,30 utura 300 300 185799 230/50/16 R134a/0,95 0,90 2,40 310 1,50 2,71 Type oefficient of performance OP Range of hot water temp. setting Range of use Maximum noise level Temperature anti-legionella cycle * mbient air 15, humidity 71%, inlet water temp. 15, Outlet water temperature 55. ** Primary temperature 80 / Secondary temp. 10 45. 1 pressure, 2 pressure test according to N 12897 P.4.4.1 3 Heating time (water temperature 60 ), mbient temp. 20, inlet water temp. 15 650 utura 250 pressure 1 / 2 oil surface bot. / top Primary Power ** utura 300 ccessories on page 69 N 255-3 N 16147 d () MPa kg m 2 kw inf/ sup --PV-PR Z utura 250 3,6 2,98 38 60-7 43 48 65 0,6/1,2 130 0,80/0,40 25,0/20,0 Rp 1 Rp 1 utura 300 3,6 2,98 38 60-7 43 48 65 0,6/1,2 155 1,30/0,80 37,0/26,0 Rp 1 Rp 1 Recirculation fittings 13

Stainless Steel Heat Pumps new 14

stand alone Inox HT PUMPS utura loor Standing SRIS 210-270-315 X Water heating system with air-source heat pump. The system envisages the use of renewable energy. ISI 316 stainless stell tank welded with TI and Plasma technology rontal inspection hatch (100x150 mm) orrosion-proof magnesium anode located on the rear and H-free very thick polyurethane (PU) foam insulation layer xternal plastic coating (PV), gray Pantone 403 Heat pump condenser coil wrapped outside the tank to avoid any contact between as and domestic hot water. djustable feet for floor standing nvironmentally-friendly gas R 134a Rotary compressor to limit the sound level 1.5 kw 230V~ electric heating element (INOX Incoloy 800) Pressure safety switch ir supply and exhaust ducting allowed lexible programming Type apacity ode Power supply Refrigerant fluid/ average load verage absorption (Heat pump only) * nominal absorption Heating time (only heat pump) 3 ccessories on page 69 lectric heating element (integration) Heat loss N 12897 / V~/Hz/ -/kg kw kw min kw kwh/24h utura 210 X 210 185807 230/50/16 R134a/0,85 0,90 2,40 227 1,50 1,84 utura 270 X 270 185809 230/50/16 R134a/0,85 0,90 2,40 280 1,50 2,30 utura 315 X 315 185812 230/50/16 R134a/0,85 0,90 2,40 335 1,50 2,71 Type oefficient of performance OP N 255-3 Range of hot water temp. heating Range of use noise level Temperature anti-legionella cycle pressure 1 / 2 Recirculation fittings Number of sensors N 16147 d () MPa kg - Z mm mm mm mm utura 210 X 3,6 2,98 38 60-7 43 48 65 0,6/1,2 97 Rp 1 Rp 1 2 1586 224 574 819 utura 270 X 3,6 2,98 38 60-7 43 48 65 0,6/1,2 107 Rp 1 Rp 1 2 1836 224 721 1069 utura 315 X 3,6 2,98 38 60-7 43 48 65 0,6/1,2 111 Rp 1 Rp 1 2 2046 224 884 1279 * mbient air 15, humidity 71%, inlet water temp. 15, Outlet water temperature 55. 1 pressure, 2 pressure test according to N 12897 P.4.4.1 3 : Heating time (water temperature 60 ), mbient temp. 20, inlet water temp. 15 650 713 K ø ST. 195 ø INT. 186 Z 706 ±2 ~ 45 15

HT PUMPS stand alone Inox Type apacity ode Type oefficient of performance OP Power supply Range of hot water temp. setting Refrigerant fluid/ average load Range of use Maximum noise level verage absorption (Heat pump only) * Temperature anti-legionella cycle pressure 1 / 2 nominal absorption Heating time (only heat pump) 3 oil surface Primary Power ** ccessories on page 69 lectric heating element (integration) N 255-3 N 16147 d () MPa kg m 2 kw --PV-PR Z utura 210 WX 3,6 2,98 38 60-7 43 48 65 0,6/1,2 101 0,60 17,21 Rp 1 Rp 1 utura 270 WX 3,6 2,98 38 60-7 43 48 65 0,6/1,2 106 0,80 18,53 Rp 1 Rp 1 utura 315 WX 3,6 2,98 38 60-7 43 48 65 0,6/1,2 118 1,30 25,22 Rp 1 Rp 1 650 Heat loss N 12897 / V~/Hz/ -/kg kw kw min kw kwh/24h utura 210 WX 210 185808 230/50/16 R134a/0,85 0,90 2,40 225 1,50 1,84 utura 270 WX 270 185810 230/50/16 R134a/0,85 0,90 2,40 280 1,50 2,30 utura 315 WX 315 185813 230/50/16 R134a/0,85 0,90 2,40 343 1,50 2,71 * mbient air 15, humidity 71%, inlet water temp. 15, Outlet water temperature 55. ** Primary temperature 80 / Secondary temp. 10 45. 1 pressure, 2 pressure test according to N 12897 P.4.4.1 3 Heating time (water temperature 60 ), mbient temp. 20, inlet water temp. 15 utura loor Standing 1 oil SRIS 210-270-315 WX Water heating system with air-source heat pump, with single coil version for integration with solar collector, fireplace stove or boiler with further advantage in terms of efficiency and comfort. The system envisages the use of renewable energy. ISI 316 stainless stell tank welded with TI and Plasma technology rontal inspection hatch (100x150 mm) orrosion-proof magnesium anode and H-free very thick polyurethane (PU) foam insulation layer Single coil optimised for maximum heat exchange and minimum limescale build-up Two sensor dry wells xternal plastic coating (PV), gray Pantone 403 Heat pump condenser coil wrapped outside the tank to avoid any contact between as and domestic hot water. nvironmentally-friendly gas R 134a Rotary compressor to limit the sound level 1.5 kw 230V~ electric heating element (INOX Incoloy 800) Pressure safety switch ir supply and exhaust ducting allowed lexible programming Recirculation fittings Type Number of sensor mm mm mm mm mm mm utura 210 WX 2 1586 224 264 574 574 819 utura 270 WX 2 1836 224 264 619 721 1069 utura 315 WX 2 2046 224 264 799 884 1279 Z PV2 K PR2 16

stand alone Inox HT PUMPS utura loor Standing 2 oil SRIS 270-315 X Water heating system with air-source heat pump, with second coil, located over the primary coil, to ensure maximum benefit using other heat sources. The system envisages the use of renewable energy. ISI 316 stainless stell tank welded with TI and Plasma technology rontal inspection hatch (100x150 mm) orrosion-proof magnesium anode located on the rear and H-free very thick polyurethane (PU) foam insulation layer ouble coil optimised for maximum heat exchange and minimum limescale build-up Two sensor dry wells xternal plastic coating (PV), gray Pantone 403 Heat pump condenser coil wrapped outside the tank to avoid any contact between as and domestic hot water. nvironmentally-friendly gas R 134a Rotary compressor to limit the sound level 1.5 kw 230V~ electric heating element (INOX Incoloy 800) Pressure safety switch ir supply and exhaust ducting allowed lexible programming Type apacity ode Type oefficient of performance OP Power supply Range of hot water temp. setting Refrigerant fluid/ average load Range of use Maximum noise level verage absorption (Heat pump only) * Temperature anti-legionella cycle nominal absorption pressure 1 / 2 Heating time (only heat pump) 3 oil surface bot. / top ccessories on page 69 lectric heating element (integration) / V~/Hz/ -/kg kw kw kw kw kw utura 270 X 270 185811 230/50/16 R134a/0,85 0,90 2,40 278 1,50 2,30 utura 315 X 315 185814 230/50/16 R134a/0,85 0,90 2,40 319 1,50 2,71 Primary Power ** Heat loss N 12897 N 255-3 N 16147 d () MPa kg m 2 kw inf/ sup --PV-PR Z utura 270 X 3,6 2,98 38 60-7 43 48 65 0,6/1,2 113 0,80/0,40 17,83/9,74 Rp 1 Rp 1 utura 315 X 3,6 2,98 38 60-7 43 48 65 0,6/1,2 123 1,30/0,60 28,51/13,26 Rp 1 Rp 1 Recirculation fittings 1 pressure, 2 pressure test according to N 12897 P.4.4.1 * mbient air 15, humidity 71%, inlet water temp. 15, Outlet water temperature 55. ** Primary temperature 80 / Secondary temp. 10 45. 3 Heating time (water temperature 60 ), mbient temp. 20, inlet water temp. 15 650 Type Numberof sensor H mm mm mm mm mm mm mm mm utura 270 X 2 1836 224 264 619 721 824 964 1069 K utura 315 X 2 2046 224 264 799 884 969 1141 1279 PV1 PR1 Z PV2 H PR2 17

lass ined Indirect ylinders 18

The STRNTHS of the product range in detail: This range of indirect cylinders performs indirect heating via one or two fixed coils with extensive heat exchange surfaces. They provide an easy and abundant supply of hot water for all uses. They can be connected to both independent and central heating systems, or to remote heating systems or they can be used in forced flow solar-powered systems, providing high heat exchange efficiency levels. The range of capacities covered by this product line is from 80 to 2000 litres with power ratings of between 20 kw and over 250 kw of heat output. The models available include undermount appliances to be fitted below the boiler, which are ideally combined with any wall-hung boiler for the production of large quantities of hot water in a limited amount of space, along with the multi-purpose free standing versions which comprise single and double coil indirect cylinders, designed to integrate several types of energy available, from methane gas via a gas boiler, to electrical installations using the integration kit available, and even solar energy systems with the forced flow solarpowered systems. The line of indirect cylinders is completed with the multiposition which has a distinguishing trait: its versatility, which makes both vertical and horizontal as well as floor-standing installations possible. Thermal Insulation Insulation layer made of very thick high-density polyurethane (PU) foam that guarantees excellent insulation. ess heat loss means lower energy waste. Tank protection against wear Thanks to the flow-coating enamelling process at 850 for guaranteed quality internal protection. Safety The products are insulated using polyurethane foam which has been certified with a fire resistance class 2 according to IN 4102 (self-extinguishing). Magnesium anode eatured in all the models in the range, this anode makes for effective electrochemical tank protection. nvironmentally friendly We strive to optimise our industrial activity while respecting the environment. To minimise the environmental impact of its products, it has abolished the use of chlorofluorocarbon (-H) in the insulation layer and makes continuous efforts to use recyclable components. 19

SS IN INIRT YINRS single coil Undermount SRIS ISSWT 120-160 Vertical single coil storage indirect cylinders are designed to be combined with any wall-hung boiler for the production of large quantities of hot water despite space restrictions. The rectangular shape can be suitably fitted as an undermount indirect cylinder. The coloured PV coating enhances its lines and protects it against possible collisions during assembly s and normal use. In addition, the product has been designed so that it can be completely disassembled at the end of its life cycle, in a way to allow its correct recycling and/or the disposal of its components. It is recommended for domestic use. Steel tank, glass-lined using the flow-coating method (850 ) ø 84 mm top inspection flange complete with counter-flange and probe sheath () orrosion-proof magnesium anode rain cock Streamlined coil for the maximum heat exchange process and to reduce the formation of limescale Outlet and recirculation fittings fittings installed in the upper part to facilitate the connection with a wall-hung boiler Self-extinguishing and very thick high-density (PS) polystyrene shell insulation layer xternal soft plastic coating (PV), white R 9010 djustable feet for floor standing Stored water temperature indicator Type apacity ode Heat exchange surface Power ( T 35 K)*.H.W. production ( T 35 K) * Heating time ( T 50 K) * low resistance Primary flow rate Insulation thickness (PS) / m 2 kw l/h mm mbar m 3 /h mm ISSWT 120 120 185682 1,15 32 780 10 170 2,0 > 30 ISSWT 160 160 185683 1,20 32 780 13 172 2,0 > 30 Type temperature temperature 1 / 2 fittings xchanger fittings Recirculation fittings Outlet fitting MPa kg - PV-PR Z mm ISSWT 120 95 0,6/1,2 54 R ¾ R ¾ R ¾ Rp ½ 845 ISSWT 160 95 0,6/1,2 64 R ¾ R ¾ R ¾ Rp ½ 1045 * Primary temperature 80 / Secondary temperature 10/45 / Primary capacity specified in the table /.H.W = Production of domestic hot water 1 pressure, 2 pressure test according to N 12897 P.4.4.1 120 Z PR 200 100 100 576 40 Power kw low resistance mbar 450 35 kw 30 25 120 160 ISSWT 120 ISSWT 160 mbar 300 120 160 20 150 15 10 1,0 1,5 2,0 2,5 3,0 0,10 1,5 2,0 2,5 3,0 low rate m³ /h low rate m³ /h 20

PV PV S PR R S PR R H H R R S single coil Vertical Wall-hung SRIS V/TS 80 200 lectric water heaters with increased heat exchanger suitable for solar application, are the basic product range devised to cater the most varied market requirements. Recommended for domestic and collective use. Steel tank, glass-lined using the flow-coating method (850 ) orrosion-proof magnesium anode High performance coil Regulation and safety rod thermostat Indicator light xternal casing made of steel shee metal coated with epoxy powderpaint and H-free very thick polyurethane (PU) foam insulation layer IPX4 protective cover over electrical parts. Stored water temperature indicator vailable with left or right hydraulic rmored copper heating element fitted on a Ø 88 mm flange with solar sensor sheath included SS IN INIRT YINRS Solar Thermal ready Type apacity ode Power Power supply Heating time ( T 50 ) temperature pressure Primary flow rate Heat exchange surface / kw V~ min MPa kg m 3 /h m 2 /kw V/TS 80 X SX 80 185947 1,5 230 23 00 95 0,8 28,5 2,0 0,6/20 V/TS 100 X SX 100 185948 1,5 230 29 00 95 0,8 33,5 2,0 0,6/20 V/TS 120 X V/TS 120 SX V/TS 150 X V/TS 150 SX V/TS 200 X V/TS 200 SX Type 120 150 200 185715 185716 185717 185718 185719 185720 Note: vailable also without heating element version, upon request 1,5 230 34 00 95 0,8 37,0 2,0 0,6/20 2,0 230 30 00 95 0,8 56,0 3,0 0,9/30 2,0 230 40 00 95 0,8 65,5 3,0 0,9/30 H M R S - PV-PR mm mm mm mm mm mm mm mm mm mm mm mm V/TS 80 X SX ½ Rp ½ 178 340 219 476 450 270 380 100 125 115 338 742 V/TS 100 X SX ½ Rp ½ 178 491 219 476 450 270 380 100 125 115 338 893 V/TS 120 X SX ¾ Rp ½ 594-241 555 540 431 486 230 156 118 248 795 V/TS 150 X SX ¾ Rp ½ 243 500 241 555 540 431 486 230 156 118 450 945 V/TS 200 X SX ¾ Rp ½ 243 800 241 555 540 431 486 230 156 118 450 1205 Version 80/100 Version 120 Version 150/200 H M M S R M 21

SS IN INIRT YINRS increased size single coil I ON SRIS ISSWH 300-400-500 Indirect cylinders with increased size single fixed coil. They are designed for an easy and abundant supply of sanitary hot water by means of heat pumps. They can be connected with central heating systems and equipped with additional integration systems. They are recommended for collective use. Steel tank, glass-lined using the flow-coating method (850 ) Ø 134 mm frontal inspection hatch 2 orrosion-proof magnesium anode HIH IINY lowered coil designed to optimise the thermal exchange and to reduce limestone Sensor sheath () located on the upper part located on the rear djustable feet for floor standing and H-free very thick polyurethane (PU) foam insulation layer Stored water temperature indicator Integration KITS available for use with tinned copper spiral heat exchangers or copper heating elements up to 5 kw and incoloy 800 stainless steel heating elements up to 10 kw with single and three-phase connection. xternal soft plastic coating (PV), white R 9016 Type apacity ode Heat exchange surface Insulation layer thickness Heat loss N 12897 temperature pressure 1 / 2 Primary flow rate * Primary temperature 80 / Secondary temperature 10/45 / Primary flow rate specified in the table /.H.W = Production of domestic hot water ccessories on page 66-67-68 Power ( T35k) *.H.W. production ( T35k) * low resistance / m 2 mm kwh/24h MPa kg m 3 /h kw l/h mbar ISSWH 300 300 185684 3,8 50 2,4 95 0,6/1,2 113 2,0 84,0 1950 425 ISSWH 400 400 185685 4,5 50 2,8 95 0,6/1,2 147 2,0 87,5 2050 461 ISSWH 500 500 185686 5,5 50 3,3 95 0,6/1,2 178 2,0 88,7 2090 563 Type w SVW SSI xchanger connection Recirculation connection Vent No. Sensor H M - PV-PR Z S mm mm mm mm mm mm mm mm mm mm ISSWH 300 Rp 1 Rp 1 Rp 1 ¾ 1 650 675 1560 148 338 828 1258 1408 1586 170 ISSWH 400 Rp 1 Rp 1 Rp 1 ¾ 1 750 775 1553 162 388 778 1228 1386 1576 190 ISSWH 500 Rp 1 Rp 1 Rp 1 ¾ 1 750 775 1818 162 391 931 1471 1651 1841 190 1 pressure, 2 pressure test according to N 12897 P.4.4.1 Power kw kw 100 90 80 70 60 50 40 30 20 10 0 0,0 0,5 1,0 1,5 2,0 2,5 300 400 500 low rate m³ /h low resistance mbar mbar 800 700 600 300 500 400 400 500 300 200 100 0 0,0 0,5 1,0 1,5 2,0 2,5 3,0 low rate m³ /h 22

* Primary temperature 80 / Secondary temperature 10/45 / Primary flow rate specified in the table /.H.W = Production of domestic hot water 2 2 1 1 2 2 PV PV 1 1 PV PV 2 2 I I multiposition single coil SS IN INIRT YINRS Multiposition SRIS MS 120 300 Multiposition Single coil heat exchanger are a convenient and cheap solution to your domestic hot water requirements. Their strength lies in the exhaustive nature of the range, from120 to 300 litres, and in the versatility of installation. Recommended for domestic and collective use. Steel tank, glass-lined using the flow-coating method (850 ) orrosion-proof magnesium anode ixed heat exchanger and H-free very thick polyurethane (PU) foam insulation layer xternal soft plastic coating (PV), gray Pantone 430 Primary circuit fittings on both sides for maximum installation flexibility Multiposition installation options: vertical or horizontal, wall-mounted or floor-standing 1 ¼ connection for heating element Type apacity ode Heat exchange surface Power ( T35k) *.H.W. production ( T35k) * Heat time ( T35k) * Primary flow rate Insulation thickness ccessories on page 66-67-68 Heat loss N 12897 temperature / m 2 kw l/h min. m 3 /h mm kwh/24h MS 120 120 185888 0,8 20,0 491,0 21,0 2,0 50 0,9 95 MS 160 160 185889 0,8 27,0 663,0 21,0 2,0 50 1,6 95 MS 200 200 185890 1,0 30,0 737,0 24,0 2,0 50 2,0 95 MS 300 300 185891 1,1 44,0 1081,0 25,0 2,0 50 2,4 95 Type Primary flow rate low resistance pressure fittings xchanger fittings H I m 3 /h mbar Mpa kg - 2 PV-PR mm mm mm mm mm mm mm mm mm MS 120 1,7 135 0,8 41 Rp 1 Rp ¾ Rp 1 550 939 113 231 687 830 231 470 411 MS 160 2,3 182 0,8 50 Rp 1 Rp ¾ Rp 1 550 1189 113 231 687 1080 231 720 411 MS 200 2,6 223 0,8 62 Rp 1 Rp ¾ Rp 1 550 1539 113 231 1287 1430 231 1070 411 MS 300 3,8 165 0,8 90 Rp 1 Rp ¾ Rp 1 650 1535 155 345 1175 1415 301 955 515 Rp 1 ¼ PR Rp 1 ¼ PR H H 440 440 mbar 180 160 140 120 100 80 60 40 20 0 Pressure loss (Heating oil) / 120-160 Heat Output T 35 / 120-160 Pressure loss (Heating oil) / 200-300 Heat Output T 35 / 200-300 0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 Watt 30000 25000 20000 15000 10000 5000 0 0,0 0,5 1,0 1,5 2,0 2,5 mbar 200 180 160 140 120 100 80 60 40 20 0 0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 50000 45000 40000 35000 30000 25000 20000 15000 10000 5000 0 0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 m 3 /h m 3 /h T = 35 m 3 /h m 3 /h T = 35 Watt 23

SS IN INIRT YINRS ree Standing One w SVW SSI Type apacity ode Heat exchange surface Power ( T35k) *.H.W. production ( T35k) * Heating time ( T35k) * low resistance Primary flow rate * Primary temperature 80 / Secondary temperature 10/45 / Primary flow rate specified in the table /.H.W = Production of domestic hot water ccessories on page 66-67-68 Insulation thickness Heat loss N 12897 single coil SRIS ISSW 120 2000 Single coil storage indirect cylinders use indirect heating. They provide an easy and abundant supply of hot water for all uses. They can be connected to central heating systems, forced flow solar-powered systems and can be fitted with further integration systems. Recommended for industrial and collective use. Steel tank, glass-lined using the flow-coating method (850 ) Ø 134 mm frontal inspection hatch (Type120 600) 2 x 134 mm frontal inspection hatch (Type 800-1000) 2 frontal inspection hatch Ø 290 mm (bot.), Ø 180 mm (top) (Type 1500-2000) orrosion-proof magnesium anode owered coil to optimise the heat exchange process and limit the formation of limescale Recirculation fitting ½ threaded fitting for sensor (). located on the rear xternal soft plastic coating (PV), white R 9016 Stored water temperature indicator djustable feet for floor standing and H-free very thick polyurethane (PU) foam insulation layer Hard polyurethane insulation, soft for models more than 1000 liters Integration KITS available for use with tinned copper spiral heat exchangers or copper heating elements of up to 5 kw and incoloy 800 stainless steel heating elements of up to 10 kw with single and three-phase connection. / m 2 kw l/h min. mbar m 3 /h mm kwh/24h ISSW 120 120 185687 0,60 20 491 15 119 2,0 50 1,00 95 ISSW 160 160 185688 0,85 27 663 15 182 2,0 50 1,80 95 ISSW 200 200 185689 1,00 30 737 17 223 2,0 50 2,20 95 ISSW 300 300 185690 1,40 44 1081 18 138 3,0 50 2,60 95 ISSW 400 400 185691 1,70 55 1351 19 180 3,0 50 3,10 95 ISSW 500 500 185692 2,10 63 1543 20 223 3,0 50 3,40 95 ISSW 600 600 185693 2,90 70 1720 22 75 3,0 50 2,90 95 ISSW 800 800 185694 3,00 88 2162 22 364 3,0 50 3,50 95 ISSW 1000 1000 185695 3,50 100 2457 24 424 3,0 50 4,10 95 ISSW 1500 1500 185892 3,90 111 2727 33 234 3,0 100 4,90 95 ISSW 2000 2000 185893 4,10 120 2948 41 246 3,0 100 5,10 95 temperature Potenza kw Perdite di carico mbar kw 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 1,0 2,0 3,0 4,0 5,0 Portata m³ /h 120 160 200 300 400 500 600 800 750 700 650 600 550 500 450 400 350 300 250 200 150 100 50 0 mbar 1,0 2,0 3,0 4,0 5,0 Portata m³ /h 120 160 200 300 400 500 600 24

single coil SS IN INIRT YINRS imensional characteristics Type Note : 1 pressure, 2 pressure test according to N 12897 P.4.4.1 SRIS 120 600 pressure 1 / 2 xchanger fittings Recirculation fittings H M MPa kg - PV-PR Z mm mm mm mm mm mm mm mm mm mm ISSW 120 0,6/1,2 45 Rp ¾ Rp ¾ Rp ¾ 610 620 854 150 311 414 486 571 631 720 ISSW 160 0,6/1,2 57 Rp ¾ Rp ¾ Rp ¾ 610 620 1056 150 311 416 551 701 781 922 ISSW 200 0,6/1,2 66 Rp ¾ Rp ¾ Rp ¾ 610 620 1329 150 311 486 651 801 881 1195 ISSW 300 0,6/1,2 97 Rp 1 Rp 1 Rp 1 650 675 1560 148 338 538 828 978 1058 1408 ISSW 400 0,6/1,2 123 Rp 1 Rp 1 Rp 1 750 775 1553 162 392 560 782 932 1012 1387 ISSW 500 0,6/1,2 144 Rp 1 Rp 1 Rp 1 750 775 1818 162 392 554 932 1082 1162 1652 ISSW 600 0,6/1,2 200 Rp 1 Rp 1 ¼ Rp 1 810 832 1819 124 331 456 871 1161 1241 1659 ISSW 800 0,6/1,2 270 Rp 2 Rp 1 ¼ Rp 1 880 902 1862 175 375 1025 1325 1675 - - ISSW 1000 0,6/1,2 295 Rp 2 Rp 1 ¼ Rp 1 880 902 2242 217 424 1242 1590 2007 - - ISSW 1500 0,6/1,2 343 Rp 2 Rp 1 ¼ Rp 1 1200 1245 2290 295 395 1740 1295 2190 - - ISSW 2000 0,6/1,2 360 Rp 2 Rp 1 ¼ Rp 1 1300 1345 2420 310 420 1710 1260 2110 - - Rp 1 ¼ SRIS 800 2000 asy ntry Systems on 800-1000 Z PV H PR 25

SS IN INIRT YINRS double coil ree Standing Two SRIS ISS 200 2000 ouble coil storage indirect cylinders use indirect heating. They provide an easy and abundant supply of hot water for all uses. They can be connected to central heating systems, forced flow solar-powered systems and can be fitted Steel tank, glass-lined using the flow-coating method (850 ) Ø 134 mm frontal inspection hatch (Type120 600) 2 x 134 mm frontal inspection hatch (Type 800-1000) 2 frontal inspection hatch Ø 290 mm (bot.), Ø 180 mm (top) (Type 1500-2000) orrosion-proof magnesium anode owered coil to optimise the heat exchange process and limit the formation of limescale Recirculation fitting ½ threaded fitting for sensor (). located on the rear xternal soft plastic coating (PV), white R 9016 Stored water temperature indicator djustable feet for floor standing and H-free very thick polyurethane (PU) foam insulation layer Hard polyurethane insulation, soft for models more than 1000 liters Integration KITS available for use with tinned copper spiral heat exchangers or copper heating elements of up to 5 kw and incoloy 800 stainless steel heating elements of up to 10 kw with single and three-phase connection w Type apacity ode ISS 200 200 185696 ISS 300 oil position Heat exchange surface Power ( T35k) *.H.W. production ( T35k) * Heating time ( T35k) * low resistance Primary flow rate * Primary temperature 80 / Secondary temperature 10/45 / Primary flow rate specified in the table /.H.W = Production of domestic hot water ccessories on page 66-67-68 Insulation thickness Heat loss N 12897 temperature / bot./top m 2 kw l/h min. mbar m 3 /h mm kwh/24h 300 185697 ISS 400 400 185698 ISS 500 SVW SSI 500 185699 ISS 600 600 185700 ISS 800 800 185701 ISS 1000 1000 185702 ISS 1500 1500 185894 ISS 2000 2000 185895 top bot. top bot. top bot. top bot. top bot. top bot. top bot. top bot. top bot. 0,50 0,70 0,90 1,40 0,90 1,70 0,90 2,10 1,00 2,50 1,20 3,00 1,60 3,60 2,30 3,90 3,60 4,10 22,0 22,5 31,5 44,0 31,5 55,0 31,5 63,0 34,0 68,0 40,0 88,0 48,0 100,0 78,0 105,0 111,0 120,0 540 533 774 1081 774 1351 774 1548 835 1671 983 2162 1179 2457 1916 2580 2727 2948 9** 22 9** 17 12** 18 16** 19 17** 22 20 ** 22 20** 24 19** 35 18** 41 119 182 100 138 100 180 100 223 64 73 148 364 170 381 230 234 180 246 2,0 50 2,20 95 3,0 50 2,60 95 3,0 50 3,10 95 3,0 50 3,40 95 3,0 50 2,90 95 3,0 50 3,70 95 3,0 50 4,30 95 3,0 100 5,10 95 3,0 100 5,40 95 **Using only the top exchanger volume that is affected will be equal to 40% of the total accumulation 26

double coil SS IN INIRT YINRS imensional characteristics Type pressure 1 / 2 xchanger fittings Recirculation fittings H M N O P MPa kg - PV-PR Z mm mm mm mm mm mm mm mm mm mm mm mm mm ISS 200 0,6/1,2 61 Rp ¾ Rp ¾ Rp ¾ 610 627 1329 150 261 391 621 691 761 841 1041 1108 1195 ISS 300 0,6/1,2 105 Rp 1 Rp 1 Rp 1 650 675 1560 156 336 466 841 912 751 984 1236 1299 1416 ISS 400 0,6/1,2 133 Rp 1 Rp 1 Rp 1 750 775 1553 162 322 437 721 799 878 976 1176 1266 1386 ISS 500 0,6/1,2 154 Rp 1 Rp 1 Rp 1 750 775 1818 161 364 479 914 981 1056 1131 1381 1456 1651 ISS 600 0,6/1,2 234 Rp 1 Rp 1 ¼ Rp 1 808 833 1819 123 330 435 945 1035 1110 1200 1452 1527 1658 ISS 800 0,6/1,2 292 Rp 2 Rp 1 ¼ Rp 1 880 902 1862 175 375 1025 1195 1325 1460 1675 - - - ISS 1000 0,6/1,2 323 Rp 2 Rp 1 ¼ Rp 1 880 925 2242 217 424 1242 1432 1590 1785 2007 - - - ISS 1500 0,6/1,2 381 Rp 2 Rp 1 ¼ Rp 1 1200 1245 2290 295 395 1630 1295 1465 1885 1995 - - - ISS 2000 0,6/1,2 417 Rp 2 Rp 1 ¼ Rp 1 1300 1345 2420 310 420 1710 1260 1400 2000 2110 - - - Note : 1 pressure, 2 pressure test according to N 12897 P.4.4.1 SRIS 200 600 2 Rp 1 ¼ P 2 P P W SRIS 800 2000 ø asy ntry Systems on 800-1000 PV2 Z PR2 PV1 H M PR1 Power kw low resistance mbar kw 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 1,0 600 inf. 500 inf. 400 inf. 300 inf. 200 inf. 600 sup. 300-500 sup. 200 sup. 250 200 150 100 50 0 2,0 3,0 4,0 1,0 2,0 3,0 low rate m³ /h low rate m³ /h mbar 700 650 600 550 500 450 400 350 300 40, 200 sup. 300-500 sup. 200 inf. 300 inf. 400 inf. 500 inf. 600 inf. 600 sup. 27

SS IN INIRT YINRS single coil ree Standing One ouble Wound SRIS ISSWP 300 1000 ouble wound cylinders are equipped with double winding coil, it means high thermic exchange for the best performance with low flow resistance. esigned for an easy and large production of domestic hot water using heat pumps, can also be connected to central heating and provided with further systems integration. Indicated for all types of users. new Steel tank, glass-lined using the flow-coating method (850 ) Ø 134 mm frontal inspection hatch (Type120 600) 2 x 134 mm frontal inspection hatch (Type 800-1000) 2 orrosion-proof magnesium anode High performance coil with lowered loops to optimize the heat exchange ow flow resistance with consequent savings in systems of circulation of the heating fluid Sensor sheath () located on the upper part located on the rear djustable feet for floor standing xternal soft plastic coating (PV), white R 9016 and H-free very thick polyurethane (PU) foam insulation layer Stored water temperature indicator Integration KITS available for use with tinned copper spiral heat exchangers or copper heating elements of up to 5 kw and incoloy 800 stainless steel heating elements of up to 10 kw with single and three-phase connection ccessories on page 66-67-68 Type apacity ode Heat exchange surface Insulation layer thickness Heating time ( T35k) ** temperature pressure 1 / 2 Primary flow rate Power ( T35k) *.H.W. production ( T35k) * low resistance / m 2 mm min MPa kg m 3 /h kw l/h mbar ISSWP 300 300 185896 3,8 50 56 95 0,6/1,2 138 4,0 13,1 322 62,7 ISSWP 400 400 185897 4,5 50 63 95 0,6/1,2 171 4,0 15,6 383 74,2 ISSWP 500 500 185898 5,5 50 64 95 0,6/1,2 201 4,0 19,0 467 90,7 ISSWP 600 600 185899 6,0 50 70 95 0,6/1,2 260 4,0 20,8 511 99,0 ISSWP 800 800 185900 6,0 50 114 95 0,6/1,2 284 1,5 20,8 420 67,0 ISSWP 1000 1000 185901 6,0 50 143 95 0,6/1,2 301 1,5 20,8 420 67,0 Type xchanger fittings Recirculation fittings Heat loss N 12897 H - PV-PR Z kwh/24h mm mm mm mm mm mm mm mm mm ISSWP 300 Rp 1 Rp 1 ¼ Rp 1 2,60 650 675 1583 145 335 825 1200 1405 1560 ISSWP 400 Rp 1 ¼ Rp 1 ¼ Rp 1 ¼ 3,10 750 775 1576 158 361 775 1183 1383 1553 ISSWP 500 Rp 1 ¼ Rp 1 ¼ Rp 1 ¼ 3,40 750 775 1841 158 361 901 1351 1648 1818 ISSWP 600 Rp 1 ¼ Rp 1 ¼ Rp 1 ¼ 2,90 808 833 1842 120 290 865 1235 1590 1819 ISSWP 800 Rp 2 Rp 1 ¼ Rp 1 ¼ 3,50 880 925 1888 191 371 911 1161 1671 1865 ISSWP 1000 Rp 2 Rp 1 ¼ Rp 1 ¼ 4,10 880 925 2268 191 371 911 1161 2050 2245 * Primary temperature 50 / Secondary temperature 10/45 / Primary flow rate specified in the table /.H.W = Production of domestic hot water Note: ** Time to heat domestic water from 10 to 45 Note : 1 pressure, 2 pressure test according to N 12897 P.4.4.1 28

single coil SS IN INIRT YINRS SRIS 300 600 O 2 PV Z 1 PR O 2 PV Z 1 PR H H SRIS 800-1000 asy ntry Systems on 800-1000 ront Rear Section 29

SS IN INIRT YINRS ree Standing Two ouble Wound double coil SRIS ISSP 500 1000 ouble wound cylinders are equipped with double winding coil, it means high thermic exchange for the best performance with low flow resistance. esigned for an easy and large production of domestic hot water using heat pumps, can also be connected to central heating and provided with further systems integration. Indicated for all types of users. new Steel tank, glass-lined using the flow-coating method (850 ) Ø 134 mm frontal inspection hatch (Type120 600) 2 x 134 mm frontal inspection hatch (Type 800-1000) 2 orrosion-proof magnesium anode High performance coil with lowered loops to optimize the heat exchange ow flow resistance with consequent savings in systems of circulation of the heating fluid Sensor sheath () located on the upper part located on the rear djustable feet for floor standing xternal soft plastic coating (PV), white R 9016 and H-free very thick polyurethane (PU) foam insulation layer Stored water temperature indicator Integration KITS available for use with tinned copper spiral heat exchangers or copper heating elements of up to 5 kw and incoloy 800 stainless steel heating elements of up to 10 kw with single and three-phase connection ccessories on page 66-67-68 Type apacity ode ISSP 500 500 185902 ISSP 600 600 185903 ISSP 800 800 185904 ISSP 1000 1000 185905 Type oil position Heat exchange surface Power ( T35k).H.W. production ( T35k) Heating time ( T35k) ** Heating time ( T50k) **** low resistance Note: * Primary temperature 50 / Secondary temperature 10/45 / Primary flow rate specified in the table /.H.W = Production of domestic hot water Primary flow rate Note: ** Time to heat domestic water from 10 to 45 ; using only the top exchanger volume that is affected will be equal to 60% of the total accumulation Note: *** Primary temperature 80 / Secondary temperature 10/45 / Primary flow rate specified in the table /.H.W = Production of domestic hot water Note: **** Time to heat domestic water from 10 to 60 temperature / top/bot. m 2 kw l/h min min mbar m 3 /h kg xchanger fittings top bot. top bot. top bot. top bot. Recirculation fittings 4,2 1,6 5,5 2,0 5,0 2,2 6,0 3,5 Insulation thickness 18,2 * 447 * 40 33,4 *** 821 *** 23,8 * 585 * 37 41,7 *** 1024 *** 22,9 * 563 * 51 45,9 *** 1128 *** 25,1 * 619 * 58 84,1 *** 1434 *** pressure 1 / 2 Heat loss N 12897 52 50 61 41 69,3 26,4 90,7 33,0 82,5 36,3 99,0 57,7 Weight 4,0 95 202 4,0 95 277 1,5 95 340 1,7 95 392 H I M - PV-PR Z mm MPa kwh/24h mm mm mm mm mm mm mm mm mm mm mm ISSP 500 Rp 1 ¼ Rp 1 ¼ Rp 1 ¼ 50 0,6/1,2 3,40 750 775 1841 158 381 681 795 981 1455 1648 1818 ISSP 600 Rp 1 ¼ Rp 1 ¼ Rp 1 ¼ 50 0,6/1,2 2,90 808 833 1842 120 290 640 835 1010 1485 1655 1819 ISSP 800 Rp 2 Rp 1 ¼ Rp 1 ¼ 50 0,6/1,2 3,70 880 925 1888 191 371 696 886 1056 1491 1671 1865 ISSP 1000 Rp 2 Rp 1 ¼ Rp 1 ¼ 50 0,6/1,2 4,30 880 925 2268 191 371 826 1071 1226 1871 2051 2245 30

O PV2 PR2 2 Z PV1 H 1 PR1 I O 3 PV2 Z PR2 M 2 PV1 H 1 PR1 I double coil SS IN INIRT YINRS SRIS 500-600 SRIS 800-1000 asy ntry Systems on 800-1000 3 M ront Rear Section 31

Indirect ylinder Inox The STRNTHS of the product range in detail: The range of stainless steel indirect cylinders is available with one or two fixed coils with large heat exchange surfaces. Provide an easy and large supply of hot water for each type of service. They can be connected to systems of heating, centralized heating or for use in solar heating systems with forced circulation allowing high yields of heat transfer. The range of volumes starts from 120 to 1000 liters with potential exchange of the coils from 20 kw to over 100 kw of power. The use of stainless steel ISI 316 (N 1.4404) ensure excellent corrosion protection and durability for long life, in addition to the top performances. Technology: The production of all stainless steel tanks is performed using the most modern and reliable technologies available as: utomated TI welding systems utomated Plasma welding systems utomated M welding systems 32

Thermal Insulation Insulation layer made of very thick high-density polyurethane (PU) foam that guarantees excellent insulation. ess heat loss means lower energy waste. Protection lasts over time: The ISI 316 Stainless Steel (N 1.4404) leads to products of excellent quality with a highly effective protection against corrosion, our products are also equipped with a magnesium anode for further cathodic protection against galvanic corrosion. Safety The products are insulated using polyurethane foam which has been certified with a fire resistance class 2 according to IN 4102 (self-extinguishing). lectronic anode vailable as an option for all products of the range, this equipment guarantees maximum electrochemical protection of the tank, no substitution need because it is not subjected to wear and tear. nvironmentally friendly We strive to optimise our industrial activity while respecting the environment. To minimise the environmental impact of its products, it has abolished the use of chlorofluorocarbon (-H) in the insulation layer and makes continuous efforts to use recyclable components. 33

INIRT YINR INOX ree Standing One Inox SRIS ISSWX 120 500 single coil Stainless steel coil storage indirect cylinders are made using technologies that guarantee maximum quality and durability owing to the use of special materials and sophisticated technological solutions such as TI and Plasma welding. Recommended for industrial and collective use. ISI 316 stainless stell tank welded with TI and Plasma technology rontal inspection hatch (100x150 mm) orrosion-proof magnesium anode owered coil to optimise the heat exchange process and limit the formation of limescale. xternal soft plastic coating (PV) gray Pantone 403 Recirculation fitting located on the rear and H-free very thick polyurethane (PU) foam insulation layer djustable feet for floor standing 1 ½ connection for heating element Type apacity ode Heat exchange surface Power ( T35k) *.H.W. production ( T35k) * Heating time ( T35k) * low resistance Primary flow rate ccessories on page 66-67-68 Insulation thickness Heat loss N 12897 / m 2 kw l/h min. mbar m 3 /h mm kwh/24h ISSWX 120 120 185871 0,60 27 663 11 115 2,0 50 1,50 95 ISSWX160 160 185872 1,10 36 896 11 117 2,0 50 1,70 95 ISSWX 200 200 185873 1,30 41 1007 12 140 2,0 50 2,00 95 ISSWX 300 300 185874 1,50 65 1597 11 178 2,0 50 2,40 95 ISSWX 400 400 185875 1,70 81 1990 12 183 2,0 50 2,80 95 ISSWX 500 500 185876 2,10 91 2236 13 235 2,0 50 3,30 95 * Primary circuit temperature 80 / Secondary circuit temperature 10/45 / Primary flow rate indicated in the table -.H.W. = Production hot water temperature Power kw low resistance mbar kw 110 100 90 80 70 60 50 40 30 20 10 1,0 2,0 3,0 4,0 5,0 120 160 200 300 400 500 mbar 700 650 600 550 500 450 400 350 300 250 200 150 100 50 0 1,0 2,0 3,0 4,0 5,0 120 160 200 300 400 500 low rate m³ /h low rate m³ /h 34

single coil INIRT YINR INOX imensional characteristics Type pressure 1 / 2 xchanger fittings Recirculation fittings Note : 1 pressure, 2 pressure test according to N 12897 P.4.4.1 Ø sensor H M N MPa kg - PV-PR Z mm mm mm mm mm mm mm mm mm mm mm mm ISSWX 120 1,0/2,0 33 Rp ¾ Rp 1 Rp ¾ 6,5 550 571 924 293 528 648 203 463 728 216 466 ISSWX 160 1,0/2,0 45 Rp ¾ Rp 1 Rp ¾ 6,5 550 571 1174 293 743 898 203 591 978 216 591 ISSWX 200 1,0/2,0 48 Rp ¾ Rp 1 Rp ¾ 6,5 550 571 1524 293 843 1248 203 729 1328 216 776 ISSWX 300 1,0/2,0 69 Rp 1 Rp 1 Rp 1 6,5 650 675 1510 377 914 1234 239 814 1294 279 859 ISSWX 400 1,0/2,0 107 Rp 1 Rp 1 Rp 1 6,5 755 784 1518 402 881 1171 266 766 1251 361 811 ISSWX 500 1,0/2,0 124 Rp 1 Rp 1 Rp 1 6,5 755 784 1782 402 1021 1436 266 891 1516 361 946 NO HZ Z PV PR H M N 35

INIRT YINR INOX ree Standing Two Inox SRIS ISSX 200 500 double coil Stainless steel double coil storage indirect cylinders are made using technologies that guarantee maximum quality and durability owing to the use of special materials and sophisticated technological solutions such as TI and Plasma welding. Recommended for industrial and collective use. ISI 316 stainless stell tank welded with TI and Plasma technology rontal inspection hatch (100x150 mm) orrosion-proof magnesium anode owered coil to optimise the heat exchange process and limit the formation of limescale. xternal soft plastic coating (PV) gray Pantone 403 Recirculation fitting located on the rear and H-free very thick polyurethane (PU) foam insulation layer djustable feet for floor standing 1 ½ connection for heating element Type apacity ode ISSX 200 ISSX 300 ISSX 400 ISSX 500 oil position Heat exchange surface Power ( T35k) *.H.W. production ( T35k) * Heating time ( T35k) * flow resistance Primary flow rate Insulation thickness ccessories on page 66-67-68 Heat loss N 12897 temperature pressure 1 / 2 / bot./sup. m 2 kw l/h min. mbar m 3 /h mm kwh/24h MPa 200 185877 300 185878 400 185879 500 185880 top bot. top bot. top bot. top bot. 0,5 1,3 0,7 1,5 0,7 1,7 1,0 2,1 25 41 32 65 32 81 36 91 614 1007 786 1597 786 1990 884 2236 8** 12 9** 11 12** 12 14** 13 110 140 130 178 130 183 117 235 2,0 50 2,00 95 1,0/2,0 3,0 50 2,40 95 1,0/2,0 3,0 50 2,80 95 1,0/2,0 3,0 50 3,30 95 1,0/2,0 * Primary circuit temperature 80 / Secondary circuit temperature 10/45 / Primary flow rate indicated in the table /.H.W. = production of domestic hot water **Using only the top exchanger volume that is affected will be equal to 40% of the total accumulation kw 015 01 95 90 85 80 75 70 65 60 45 40 55 50 2 20 35 30 0 5 01 51 1, 0 2, 0 Power kw low resistance mbar 3, 0 4, 0 5, 0 200 inf. 300-500 sup. 300 inf. 400 inf. 500 inf. mbar 500 450 400 350 300 250 200 150 100 50 0 1, 0 2, 0 3, 0 4, 0 5, 0 200 inf. 300-500 sup. 300 inf. 400 inf. 500 inf. low rate m³ /h low rate m³ /h 36

double coil INIRT YINR INOX imensional characteristics Type ISSX 200 ISSX 300 ISSX 400 ISSX 500 xchanger fittings Recirculation fittings Ø sensor H M N O P kg - PV-PR Z mm mm mm mm mm mm mm mm mm mm mm mm mm mm 54,5 Rp ¾ Rp 1 Rp ¾ 6,5 550 571 1524 293 843 1248 203 729 1328 216 776 936 1136 77,0 Rp 1 Rp 1 Rp 1 6,5 650 675 1510 377 914 1234 239 814 1294 279 859 989 1189 115,3 Rp 1 Rp 1 Rp 1 6,5 755 784 1518 402 881 1171 266 766 1251 361 811 971 1131 136,0 Rp 1 Rp 1 Rp 1 6,5 755 784 1782 402 1021 1436 266 891 1516 361 946 1106 1346 Note : 1 pressure, 2 pressure test according to N 12897 P.4.4.1 NO PV2 HZ 2 Rp 1/2 Z PR2 PV1 1 PR1 H M N O P 37

INIRT YINR INOX high storage ree Standing High Storage 1or 2 oil SRIS ISSWX e ISSX 800-1000 One and ouble fixed coil floor-standing storage indirect cylinders are designed to meet the new expectations of the market as to durability, exchange power and great storage. To this end, this product line was introduced, providing great capacities, maximum quality and durability owing to the use of special materials and sophisticated technological solutions, such as TI and plasma welding. The insulation layer is manufactured by means of a new system that combines the technology of the injected polyurethane (PU) with the flexibility of NOPOR (PS). This solution allows the installer to have a plug and play product and, in case of need, it is an easy solution for making the product pass through openings whose width equals 800 mm. This system allows a troublefree disassembly and re-assembly of the insulation layer for an easier installation in boiler rooms. The two big front hatchways characterise the line of these products and make them flexible and suitable for several combinations of electrical integrations. They are recommended for collective use. ISI 316 stainless stell tank welded with TI and Plasma technology 2 x 134 mm frontal inspection hatch TRONI TITNIUM NO xternal soft plastic coating (PV) gray R 9006 xchangers with lowered turns to streamline the heat exchange and reduce the formation of limescale. Stored water temperature djustable feet for floor standing indicator They are available in electrical integration kits with the use of Incoloy 800 stainless steel heating elements up to 10 kw with single- and three-phase. and H-free very thick polyurethane (PU)/ (PS) foam insulation layer asy entry systems ree Standing Inox High Storage with 1 oil Type apacity ode Heat exchange surface Power ( T35k) *.H.W. production ( T35k) * Heating time ( T35k) * low resistance Primary flow rate Insulation thickness ccessories on page 66-67-68 Heat loss N 12897 temperature / m 2 kw l/h min. mbar m 3 /h mm kwh/24h ISSWX 800 800 185634 3,05 110 2702 18 364 3,0 50 4,6 95 ISSWX 1000 1000 185635 3,55 130 3194 19 420 3,0 50 5,0 95 Type apacity ode ISSX 800 ISSX 1000 ree Standing Inox High Storage with 2 oils oil Position Heat exchange surface Power ( T35k) *.H.W. production ( T35k) * Heating time ( T35k) * low resistance Primary flow rate Insulation thickness Heat loss N 12897 / bot./sup. m 2 kw l/h min. mbar m 3 /h mm kwh/24h 800 185636 1000 185637 top bot. top bot. 1,30 3,05 1,30 3,55 59 110 59 130 1449 2702 1460 3194 13** 18 17** 19 155 364 155 420 temperature 3,0 50 4,6 95 3,0 50 5,0 95 * Note : Primary circuit temperature 80 / Secondary circuit temperature 10/45 / Primary flow rate indicated in the table /.H.W. = production of domestic hot water **Using only the top exchanger volume that is affected will be equal to 40% of the total accumulation 38

high storage INIRT YINR INOX PV Z H H imensional characteristics ISSWX (1 oil) Type pressure 1 / 2 xchanger fittings Recirculation fittings H MPa kg - PV-PR Z mm mm mm mm mm mm mm mm ISSWX 800 0,6/1,2 195 Rp 1 ¼ Rp 1 ¼ Rp 1 ¼ 880 925 1865 320 425 982 1187 1580 ISSWX 1000 0,6/1,2 226 Rp 1 ¼ Rp 1 ¼ Rp 1 ¼ 880 925 2245 320 425 1165 1303 1960 Note : 1 pressure, 2 pressure test according to N 12897 P.4.4.1 PR imensional characteristics ISSX (2 oils) Type pressure 1 / 2 xchanger fittings Recirculation fittings H M MPa kg - PV-PR Z mm mm mm mm mm mm mm mm mm mm ISSX 800 0,6/1,2 206 Rp 1 ¼ Rp 1 ¼ Rp 1 ¼ 880 925 1865 320 425 985 1090 1178 1475 1580 ISSX 1000 0,6/1,2 237 Rp 1 ¼ Rp 1 ¼ Rp 1 ¼ 880 925 2245 320 425 1187 1340 1578 1855 1960 Note : 1 pressure, 2 pressure test according to N 12897 P.4.4.1 Ø PV2 PR2 Z PV1 M PR1 39

uffer ylinders 40

The STRNTHS of the product range in detail: The range of buffer cilinders is formed by heating water storages with the opportunity to combine a fixed coil exchanger, too. They allow storing heating water generated by discontinuous heating systems; therefore, they allow a considerable recovery and/or exploitation of thermal energy that would be unused or even wasted. rom this point of view, they well integrate into energy saving systems, and become the thermal source of the energy system within heating and domestic hot water generation systems. Owing to their peculiarity, they are usually connected to systems that generate heat in a discontinuous way, such as for example wood-fired boilers, solid-fuel stacks or stoves, or rather installed in low water systems to limit the interventions of the burners. s for the version with fixed exchanger, besides what is said above, it is used for maximum exploitation of thermal solar systems or with heat pump. The capacity field covered by this range is included between 200 and 2,000 litres. Product lines cover the standard, with front hatchway, solar with fixed exchanger and front hatchway up to solar with the production of domestic hot water. ll products are equipped with fittings for electric integrations by means of specific kits from 3.0 kw to 12.0 kw, while the products having the hatchway can install further electric kits from 2.0 to 10.0 kw, or kits with tinned copper spiroid exchangers. Thermal Insulation Insulation layer made of very thick high-density polyurethane (PU) foam that guarantees excellent insulation. ess heat loss means lower energy waste. Safety The products are insulated using polyurethane foam which has been certified with a fire resistance class 2 according to IN 4102 (self-extinguishing). nvironmentally friendly We strive to optimise our industrial activity while respecting the environment. To minimise the environmental impact of its products, it has abolished the use of chlorofluorocarbon (-H) in the insulation layer and makes continuous efforts to use recyclable components. 41

UR YINRS buffer cylinders for heating systems uffer SRIS ISPHSO 200 2000 The inertial accumulators are characterized by the ability to accumulate heating water coming from multiple sources, especially discontinuous ones. Moreover, they are ready for mounting electrical integration, supplied through specific kits up to 9 kw. Raw carbon steel tank located on the rear ½ threaded fitting for sensor () and H-free very thick polyurethane (PU) foam insulation layer asy entry systems plus (PS) for series 800-1000 Hard polyurethane insulation, soft for models more than 1000 liters xternal soft plastic coating (PV), white R 9016 djustable feet for floor standing 1 ½ connection for heating element w SVW SSI Type apacity ode Insulation thickness temperature pressure Heating element fitting ccessories on page 66-67-68 itting on upper bottom No. sensor / Ø Heat loss N 12897 / mm MPa kg Rp M,RI,R,S,Rc Rp Nr/mm kwh/24h ISPHSO 200 200 185860 50 95 0,3 51 Rp 1 ½ Rp 1 ¼ Rp 1 ¼ 4/Rp ½ 1,8 ISPHSO 300 300 185861 50 95 0,3 75 Rp 1 ½ Rp 1 ¼ Rp 1 ¼ 4/Rp ½ 2,0 ISPHSO 400 400 185862 50 95 0,3 97 Rp 1 ½ Rp 1 ¼ Rp 1 ¼ 4/Rp ½ 2,2 ISPHSO 500 500 185863 50 95 0,3 113 Rp 1 ½ Rp 1 ¼ Rp 1 ¼ 4/Rp ½ 2,4 ISPHSO 600 600 185864 50 95 0,3 174 Rp 1 ½ Rp 1 ¼ Rp 1 ¼ 4/Rp ½ 2,6 ISPHSO 800 800 185866 50 95 0,3 140 Rp 1 ½ Rp 1 ½ Rp 1 ¼ 4/Rp ½ 2,8 ISPHSO 1000 1000 185867 50 95 0,3 164 Rp 1 ½ Rp 1 ½ Rp 1 ¼ 4/Rp ½ 3,4 ISPHSO 1500 1500 185257 100 95 0,3 231 Rp 1 ½ Rp 1 ½ Rp 1 ½ 4/Rp ½ 4,9 ISPHSO 2000 2000 185258 100 95 0,3 276 Rp 1 ½ Rp 1 ½ Rp 1 ½ 4/Rp ½ 5,1 Type H M mm mm mm mm mm mm mm mm mm mm ISPHSO 200 610-1310 256 808 1051 448 653 858 1063 ISPHSO 300 650-1541 201 948 1245 475 735 995 1255 ISPHSO 400 750-1534 309 925 1201 522 752 982 1212 ISPHSO 500 750-1799 309 1102 1466 589 885 1181 1477 ISPHSO 600 810-1800 248 1102 1496 550 869 1188 1507 ISPHSO 800 880 1862 310 680 1060 1520 - - - - ISPHSO 1000 880 2242 351 785 1355 1850 - - - - ISPHSO 1500 1200 2198 380 825 1350 1760 - - - - ISPHSO 2000 1300 2420 320 900 1490 2020 - - - - 42

buffer cylinders for heating systems UR YINRS VRSION ISPHSO 200 600 15 30 H M Rp 1 ½ Rp 1 ½ VRSION ISPHSO 800 2000 Ø 43

UR YINRS uffer 1or 2 oils solar buffers cylinders SRIS ISPHSW e 600 2000 The inertial accumulators are characterized by the ability to accumulate heating water coming from multiple sources, especially discontinuous ones. Moreover, they are ready for mounting electrical integration, supplied through specific kits up to 9 kw. Raw carbon steel tank located on the rear ½ threaded fitting for sensor () and H-free very thick polyurethane (PU) foam insulation layer asy entry systems plus (PS) for series 800-1000 Hard polyurethane insulation, soft for models more than 1000 liters xternal soft plastic coating (PV), white R 9016 djustable feet for floor standing 1 ½ connection for heating element uffer cylinders with 1 coil series w ccessories on page 66-67-68 Type apacity ode Insulation thickness temperature pressure Heating element fitting itting on upper bottom No. sensor / Ø Heat loss N 12897 / mm MPa kg Rp M,RI,R,S,Rc Rp Nr/Rp kwh/24h ISPHSW 600 600 185906 50 95 0,3 170 Rp 1 ½ Rp 1 ¼ Rp 1 ¼ 4/Rp ½ 3,0 ISPHSW 750 750 185907 50 95 0,3 205 Rp 1 ½ Rp 1 ½ Rp 1 ¼ 4/Rp ½ 3,5 ISPHSW 950 950 185908 50 95 0,3 241 Rp 1 ½ Rp 1 ½ Rp 1 ¼ 4/Rp ½ 4,1 ISPHSW 1500 1500 185909 100 95 0,3 283 Rp 1 ½ Rp 1 ½ Rp 1 ½ 4/Rp ½ 4,7 ISPHSW 2000 2000 185910 100 95 0,3 334 Rp 1 ½ Rp 1 ½ Rp 1 ½ 4/Rp ½ 5,1 Type Heat exchange surface Power ( T35k) * Production H.W. ( T35k) * Heating time ( T35k) * Primary flow rate xchanger fittings m 2 kw l/h min m 3 /h PV-PR ISPHSW 600 1,80 55,0 1351 27 3,0 Rp 1 ISPHSW 750 2,70 82,5 2027 22 3,0 Rp 1 ISPHSW 950 3,00 92,0 2260 25 3,0 Rp 1 ISPHSW 1500 3,60 110,0 2702 33 3,0 Rp 1 ISPHSW 2000 4,20 129,5 3181 28 3,0 Rp 1 uffer cylinders with 2 coils series ww Type apacity ode Insulation thickness temperature pressure Heating element fitting * Note : Primary circuit temperature 80 / Secondary circuit temperature 10/45 / Primary flow rate indicated in the table / H.W. = Production hot water **Using only the top exchanger volume that is affected will be equal to 40% of the total accumulation itting on upper bottom No. sensor / Ø Heat loss N 12897 / mm MPa kg Rp M,RI,R,S,Rc Rp Nr/Rp kwh/24h ISPHS 600 600 185911 50 95 0,3 180 Rp 1 ½ Rp 1 ¼ Rp 1 ¼ 4/Rp ½ 3,0 ISPHS 750 750 185912 50 95 0,3 220 Rp 1 ½ Rp 1 ½ Rp 1 ¼ 4/Rp ½ 3,5 ISPHS 950 950 185913 50 95 0,3 260 Rp 1 ½ Rp 1 ½ Rp 1 ¼ 4/Rp ½ 4,1 ISPHS 1500 1500 185914 100 95 0,3 308 Rp 1 ½ Rp 1 ½ Rp 1 ½ 4/Rp ½ 4,7 ISPHS 2000 2000 185915 100 95 0,3 369 Rp 1 ½ Rp 1 ½ Rp 1 ½ 4/Rp ½ 5,1 Type Heat exchange surface Power ( T35k) * Production H.W. ( T35k) * Heating time ( T35k) * Primary flow rate xchanger fittings bot./top (m 2) kw l/h min m 3 /h PV-PR ISPHSW 600 1,80/1,20 55,0/40,0 1351 / 983 27 / 15** 3,0/3,0 Rp 1 ISPHSW 750 1,80/2,00 55,0/68,0 1351 / 1671 33 / 11** 3,0/3,0 Rp 1 ISPHSW 950 2,00/2,20 68,0/74,0 1671 / 1818 34 / 13** 3,0/3,0 Rp 1 ISPHS 1500 2,70/2,40 82,5/81,6 2027 / 2005 44 / 18** 3,0/3,0 Rp 1 ISPHS 2000 3,70/2,60 110,0/88,0 2702 / 2162 44 / 22** 3,0/3,0 Rp 1 44

M N H I Ø Ø M N H O P H I Ø Ø H I solar buffers cylinders UR YINRS uffer cylinders with 1 coil series w ISPHSW 600 ISPHSW 800 2000 Type H I M N mm mm mm mm mm mm mm mm mm mm mm mm ISPHSW 600 800 780 1800 248 1035 1496 550 869 1188 1507 305 845 ISPHSW 750 880 1862 310 680 1060 1520 360 720 - - - - ISPHSW 950 880 2242 351 785 1355 1850 400 820 - - - - ISPHSW 1500 1200 2198 380 825 1350 1760 380 1180 - - - - ISPHSW 2000 1300 2240 320 900 1490 2020 320 1120 - - - - uffer cylinders with 2 coils series ww ISPHS 600 ISPHS 800 2000 Type H I M N O P mm mm mm mm mm mm mm mm mm mm mm mm mm mm ISPHS 600 800 780 1800 248 1035 1496 550 869 1188 1507 305 845 1080 1435 ISPHS 750 880 1862 310 680 1060 1520 360 720 1110 1520 - - - - ISPHS 950 880 2242 351 785 1355 1850 400 820 1410 1880 - - - - ISPHS 1500 1200 2220 380 825 1350 1762 390 780 1410 1762 - - - - ISPHS 2000 1300 2420 320 900 1490 2020 320 1120 1420 2020 - - - - 45

UR YINRS buffers solar cylinders whit.h.w. production Pipe in Tank PTS SRIS PTSW e PTS 600 2000 Pipe In Tank solar cylinders main feature is the ability to store energy from multiple heat sources, with temperatures up to 95. Pipe In Tank solar cylinders are available with single or double solar coil and they are equipped with a system of aerators that grant an optimal level of stratification of the storage water at different temperatures. The instantaneous production of domestic hot water is guaranteed by a stainless steel coil: this system provides maximum safety against the formation of bacterial colonies. Raw carbon steel tank Stainless steel 316 finned coil for the instantaneous production of domestic hot water Single or double solar coil xternal soft plastic coating (PV), white R 9016 no. 8 fittings (1 ½ ) to connect other heating sources. 1 ½ connection for heating element located on the rear and H-free very thick polyurethane (PU) foam insulation layer Hard polyurethane insulation, soft for models more than 1000 liters djustable feet for floor standing Type PTS W with 1 coil Tank apacity.h.w. apacity ode Insulation thickness Heat exchange surface.h.w. Heat exchange surface temperature pressure No. sensor ccessories on page 66-67-68 Heat exchange fittings.h.w. fittings / / mm m 2 m 2 Tank/.H.W.(MPa) No/ PV-PR - PTS 600 W 600 30,5 185916 50 6,0 1,8 95 0,3/0,8 3 / ½ Rp 1 ½ Rp 1 ¼ Rp 1 PTS 800 W 800 30,5 185917 50 6,0 2,0 95 0,3/0,8 3 / ½ Rp 1 ½ Rp 1 ¼ Rp 1 PTS 1000 W 1000 30,5 185918 50 6,0 2,5 95 0,3/0,8 3 / ½ Rp 1 ½ Rp 1 ¼ Rp 1 PTS 1500 W 1500 50,5 185919 100 9,8 2,7 95 0,3/0,8 4 / ½ Rp 1 ½ Rp 1 Rp 1 PTS 2000 W 2000 50,5 185920 100 9,8 3,7 95 0,3/0,8 4 / ½ Rp 1 ½ Rp 1 Rp 1 Type PTS with 2 coils Tank apacity.h.w. apacity ode Insulation thickness Heat exchange surface.h.w. Heat exchange surface temperature pressure No. sensor Heat exchange fittings.h.w. fittings / / mm m 2 bot./top (m 2 ) Tank/.H.W.(MPa) No/mm PV-PR - PTS 600 600 30,5 185921 50 6,0 1,8/1,8 95 0,3/0,8 3 / ½ Rp 1 ½ Rp 1 ¼ Rp 1 PTS 800 800 30,5 185922 50 6,0 2,0/2,0 95 0,3/0,8 3 / ½ Rp 1 ½ Rp 1 ¼ Rp 1 PTS 1000 1000 30,5 185923 50 6,0 2,5/2,5 95 0,3/0,8 3 / ½ Rp 1 ½ Rp 1 ¼ Rp 1 PTS 1500 1500 50,5 185924 100 9,8 2,7/2,4 95 0,3/0,8 4 / ½ Rp 1 ½ Rp 1 Rp 1 PTS 2000 2000 50,5 185925 100 9,8 3,7/2,6 95 0,3/0,8 4 / ½ Rp 1 ½ Rp 1 Rp 1 46

I PTS W with 1 coil 600 1000 Ø S 1500-2000 Ø S Rp 1 ½ Rp 1 ½ H PV N M I PV H PRØ S S 1 PTS with 2 coils Type H I M N Ø mm mm mm mm mm mm mm mm mm mm mm mm PTS 600 W 810 1800 253 355 698 785 1048 1473 - - - - PV PTS 800 W 880 1862 301 403 853 853 1133 1521 - - - - PTS 1000 W 880 2242 314 416 866 992 1335 PV1 1888 - - - - PR PTS 1500 W 1200 2020 235 335 380 390 780 825 1350 1350 1762 1835 PTS 2000 W 1300 2420 220 305 320 320 1120 900 1315 1490 2020 1805 Rp 1 ½ O N M PR1 Rp 1 ½ PV2 600 1000 H 1500-2000 PR2 Ø S S 1 PV1 PV 1 PR 1 PV 2 H I I I buffers solar cylinders whit.h.w. production UR YINRS PR Ø S H H PV PR Rp 1 ½ Rp 1 ½ N M S 1 Ø S PR1 Rp 1 ½ O N M PV2 Rp 1 ½ PR 2 H PR2 S 1 Type H I M N O mm mm mm mm mm mm mm mm mm mm mm mm mm PTS 600 810 1800 253 355 698 785 941 1048 1371 1473 - - - PTS 800 880 1862 301 403 853 853 969 1133 1419 1521 - - - PTS 1000 880 2242 314 416 866 992 1210 1335 1786 1888 - - - PTS 1500 1200 2020 235 335 380 390 780 825 1350 1350 1410 1762 1835 PTS 2000 1300 2420 220 305 320 320 1120 900 1315 1490 1420 2020 1805 47

UR YINRS hilled water buffer cylinders SRIS ISSR 200 2000 These buffers are used in refrigeration systems with limited water content, to ensure a constant average temperature and to reduce the need of the compressor Raw carbon steel tank located on the rear and H-free very thick polyurethane (PU) foam insulation layer Hard polyurethane insulation, soft for models more than 1000 liters asy ntry Systems on (PS) for S- RIS 800/1000 xternal soft plastic coating (PV), white R 9016 djustable feet for floor standing Refrigeration from 7 to 12. or temperatures below 0 it is recommended to add the water with ethylene glycol at 15% or at least equivalent coolant new Type apacity ode Insulation thickness temperature pressure itting on upper bottom No. sensor / Ø / mm MPa kg S-S No/Rp ISSR 200 200 185926 50 95 0,8 38 Rp 1 ½ Rp 1 ¼ 3 / Rp ½ ISSR 300 300 185927 50 95 0,8 56 Rp 2 Rp 1 ¼ 3 / Rp ½ ISSR 500 500 185928 50 95 0,8 95 Rp 3 Rp 1 ¼ 3 / Rp ½ ISSR 800 800 185929 50 95 0,8 145 Rp 3 Rp 1 ¼ 3 / Rp ½ ISSR 1000 1000 185930 50 95 0,8 154 Rp 3 Rp 1 ¼ 3 / Rp ½ ISSR 1500/20 1500 185931 20 95 0,8 231 Rp 3 Rp 1 ¼ 3 / Rp ½ ISSR 1500/20-80 1500 185932 20+80 95 0,8 231 Rp 3 Rp 1 ¼ 3 / Rp ½ ISSR 2000/20 2000 185933 20 95 0,8 276 Rp 3 Rp 1 ¼ 3 / Rp ½ ISSR 2000/20-80 2000 185934 20+80 95 0,8 276 Rp 3 Rp 1 ¼ 3 / Rp ½ Type mm mm mm mm mm mm mm ISSR 200 550 1524 98 224 579 934 1289 ISSR 300 650 1524 140 320 620 920 1220 ISSR 500 755 1768 146 354 710 1070 1428 ISSR 800 880 1862 171 351 725 1098 1471 ISSR 1000 880 2242 171 351 851 1351 1851 ISSR 1500/20 1040 2198 380 825 1350 1760 - ISSR 1500/20-80 1200 2198 380 825 1350 1760 - ISSR 2000/20 1140 2420 320 900 1490 2020 - ISSR 2000/20-80 1300 2420 320 900 1490 2020 - VRSION 200 1000 VRSION 1500-2000 Ø S 1" 1/4 1" 1/4 S S 1 ¼ Ø 48

as Water Heaters The range of gas water heaters is the result of detailed research and in-depth experiments related to the efficiency, safety, aesthetic appearance and energy savings in strict compliance with the applicable norms in force. The range of capacities covered by this product line is from 50 to 2000 litres with power ratings of between 4 kw and over 34 kw of heat output. The range meets both the domestic requirements of a typical home as well as those of industrial and collective settings. The product lines include natural draught appliances, which are ideal for the rapid and cheap production both small and large quantities of water, as well as the sophisticated fan flue appliances which also solve installation difficulties when traditional systems cannot be fitted. The STRNTHS of the product range in detail: Thermal insulation Insulation layer made of very thick (range for collective use) high-density polyurethane (PU) foam that guarantees excellent insulation. ess heat loss means lower energy waste. Tank protection against wear Thanks to the flow-coating enamelling process at 850 for guaranteed quality internal protection or via classic hot galvanising process (for series 600-2000 only). Magnesium anode eatured in all the models in the range, this anode makes for effective electrochemical tank protection. Multi-gas burner ll the gas powered appliance models are fitted with multi-gas burners for operation with methane gas or P. Maximum safety iple safety gas valve with thermostat, flame detection thermocouple (ionisation for electronic versions) and maximum temperature thermostat and flue gas sensor (for natural draught versions) to avoid possible malfunctions. nvironmentally friendly We strive to optimise its industrial activity while respecting the environment. To minimise the environmental impact of its products, it has abolished the use of chlorofluorocarbons (-H) in the insulation layer and makes continuous efforts to use recyclable components. 49

S WTR HTRS open-flue Natural raught Wall-hung SRIS N 50 120 Wall-hung storage open-flue and Natural draught gas water heaters are the simplest and cheapest solution for the rapid production of domestic hot water. Steel tank, glass-lined using the flow-coating method (850 ) orrosion-proof magnesium anode and H-free very thick polyurethane (PU) foam insulation layer xternal casing made of sheet metal coated with epoxy powder pain Piezoelectric ignition urner with 3 distributing pipes iple safety gas valve: thermostat, flame detection thermocouple and maximum temperature control lue gas sensor () Stored water temperature indicator esigned to operate on methane gas or P (nozzles included) Operation without electrical Type apacity ode Heat Output Useful Power Heating time T=50 ont. flow rate T= 30 qty. of flue gases lue gas temp. Methane consuption P consumption temperature pressure Ø lue gas discharge / kw kw min l/min g/s m 3 /h g/h MPa kg (mm) N 50 45 169012 4,5 3,8 43 1,8 1,96 308 0,50 300 75 0,8 20 81 N 80 80 169102 6,2 5,3 55 2,5 2,75 292 0,65 395 75 0,8 28 81 N 100 94 169173 6,2 5,3 65 2,5 3,22 284 0,65 395 75 0,8 32 81 N 120 118 169262 6,5 5,6 77 2,7 3,31 275 0,70 425 75 0,8 36 81 Note: Open flue, Natural draught 1185 ategory II 2H3+ Type as fitting - mm mm 348 112 475 N 50 ½ 3/8 654 261 N 80 ½ 3/8 939 546 N 100 ½ 3/8 1024 631 N 120 ½ 3/8 1174 781 100 450 22 View Vista from da sotto above 50

open-flue Natural raught loor Standing SRIS /P 150-200 loor-standing storage open-flue and Natural draught gas water heaters are the best solution for the production and store of large quantities of domestic hot water. These water heaters are ideal for collective use (on campsites, in sport facilities and hotel, for example) and industrial settings. S WTR HTRS Steel tank, glass-lined using the flow-coating method (850 ) orrosion-proof magnesium anode and H-free very thick polyurethane (PU) foam insulation layer xternal casing made of sheet metal coated with epoxy powder pain Piezoelectric ignition Stored water temperature indicator iple safety gas valve: thermostat, flame detection thermocouple and maximum temperature control lue gas sensor () esigned to operate on methane gas or P (nozzles included) Operation without electrical Type apacity ode Heat Output Note: Open flue, Natural draught 1185 ategory II 2H3+ Useful Power Heating time T=50 ont. flow rate T= 30 qty. of flue gases lue gas temp. Methane consuption P consumption temperature pressure Ø lue gas discharge / kw kw min l/min g/s m 3 /h g/h MPa kg (mm) /P 150 150 185643 7,2 6,0 92 2,8 3,80 242 0,76 445 75 0,8 50 81 /P 200 200 185644 7,6 6,6 111 3,2 3,76 234 0,84 495 75 0,8 71 81 Type Recirculation and discharge as fitting - Z mm mm mm /P 150 R ¾ Rp ¾ R ½ 1511 1573 824 /P 200 R ¾ Rp ¾ R ½ See diagram 470 570 Version 150 Version 200 Z 230 65 1479 1417 Z 230 118 118 374 1479 70 Z 259 669 Z 51

S WTR HTRS open-flue Natural raught loor Standing Medium Sizes SRIS /PR e /PR 300-500 loor-standing storage open-flue and Natural draught gas water heaters are the best solution for the production and store of large quantities of domestic hot water. The version featuring electronic ignition combines economic use with maximum flame control precision. These water heaters are ideal for collective use (on campsites, in sport facilities and hotel, for example) and industrial settings. Steel tank, glass-lined using the flow-coating method (850 ) Ø 134 mm frontal inspection hatch orrosion-proof magnesium anode and H-free very thick polyurethane (PU) foam insulation layer xternal casing made of sheet metal coated with epoxy powder pain Piezoelectric ignition lue gas sensor () Piezoelectric ignition (electronic for /PR version) iple safety gas valve: thermostat, flame detection thermocouple (ionisation for the /PR version) and maximum temperature control. Stored water temperature indicator esigned to operate on methane gas or P (nozzles included) Operation without electrical (/PR version) Type apacity ode Heat Output Useful Power Heating time T=50 ont. flow rate T= 30 qty. of flu gases lue gas temp. Methane consuption P consumption temperature pressure Ø lue gas discharge / kw kw min l/min g/s m 3 /h g/h MPa kg (mm) /PR 300 290 185645 19,5 17,2 62 8,2 9,59 230 2,10 1250 75 0,8 133 122 /PR 300 * 290 185646 19,5 17,2 62 8,2 9,59 230 2,10 1250 75 0,8 133 122 /PR 500 470 185647 24,0 21,0 82 10,0 11,58 214 2,52 1500 75 0,8 178 122 /PR 500 * 470 185648 24,0 21,0 82 10,0 11,58 214 2,52 1500 75 0,8 178 122 Nota: * lectronic version must be connected to the mains supply 230V~ / Open flue, Natural draught 1185 ategory II 2H3+ Type Recirculation and discharge as fitting - Z mm mm mm /PR 300 Rp 1 Rp ¾ R ¾ 1611 821 1084 /PR 300 Rp 1 Rp ¾ R ¾ 1611 821 1084 /PR 500 Rp 1 Rp ¾ R ¾ 2144 1285 1643 /PR 500 Rp 1 Rp ¾ R ¾ 2144 1285 1643 720 Z 499 499 52

open-flue S WTR HTRS Natural raught loor Standing ig Sizes SRIS /P e /P 600 2000 loor-standing storage open-flue and Natural draught gas water heaters are the best solution for the production and store of large quantities of domestic hot water. The version featuring electronic ignition combines economic use with maximum flame control precision. These water heaters are ideal for collective use (on campsites, in sport facilities and hotel, for example) and industrial settings. Hot galvanised steel tank orrosion-proof magnesium anode Very thick mineral wool insulation layer for reduced heat loss Stored water temperature indicator xternal casing made of sheet metal coated with epoxy powder pain Piezoelectric ignition (electronic for /P version) iple safety gas valve: thermostat, flame detection thermocouple and maximum temperature control lue gas sensor () esigned to operate on methane gas or P (nozzles included) Operation without electrical (/P version) Type apacity ode /P 600 /P 600 * 575 /P 800 /P 800 * 800 /P 1000 /P 1000 * 950 /P 1500 /P 1500 * 1450 /P 2000 /P 2000 * 1850 Heat Output Useful Power Heating time T=50 ont. flow rate T= 30 qty. of flue gases lue gas temp. Methane consuption Nota: * lectronic version must be connected to the mains supply 230V~ / Open flue, Natural draught 1185 ategory II 2H3+ P consumption temperature pressure Ø lue gas discharge / kw kw min l/min g/s m 3 /h g/h MPa kg (mm) 185649 185650 185651 185652 185653 185654 185655 185656 185657 185658 26,7 22,9 92 10,9 23,2 136 2,70 1988 75 0,6 194 140 34,8 29,9 98 14,3 31,1 135 3,60 2581 75 0,6 241 160 34,8 30,2 115 14,3 31,1 135 3,60 2581 75 0,6 276 160 34,8 29,6 180 14,1 31,1 135 3,60 2581 75 0,6 377 160 34,8 30,2 225 14,3 31,1 135 3,60 2581 75 0,6 452 160 Type Recirculation and discharge as fitting - Z mm mm mm mm mm mm /P 600 Rp 1 Rp 1 R ½ 780 2165 2000 1730 1010 310 /P 800 Rp 1 ¼ Rp 1 ¼ R ½ 980 1975 1810 1470 900 340 /P 1000 Rp 1 ¼ Rp 1 ¼ R ½ 1080 2025 1860 1470 900 340 /P 1500 Rp 1 ¼ Rp 1 ¼ R ½ 1180 2255 2090 2000 960 340 /P 2000 Rp 1 ¼ Rp 1 ¼ R ½ 1280 2475 2310 2150 960 340 Z 53

S WTR HTRS room-sealed an lue loor Standing SRIS T 220-300-400 loor-standing storage room-sealed and fan flue gas water heaters feature the most advanced technological solutions to solve the most challenging installation problems. Their electronic controls makes them ideal for collective use (on campsites, in sports facilities and hotels, for example) and in industrial settings. Steel tank, glass-lined using the flow-coating method (850 ) orrosion-proof magnesium anode con dispositivo di controllo anodo and H-free very thick polyurethane (PU) foam insulation layer xternal casing made of PV covered zinc plated sheet metal lectronic ignition with flame detection and ionisation flame control lue gas extraction fan with safety pressure switch iple safety gas valve: thermostat, ionisation flame detection and maximum temperature control Safety hydraulic pressure valve Stored water temperature indicator esigned to operate on methane gas or P (nozzles included) oaxial or split flue gas discharge available ccording to uropean standards: 2009/142 2006/95 V 2004/108 M Type apacity ode Heat Output Useful Power Heating time T=50 ont. flow rate T= 30 qty. of flue gases lue gas temp. Methane consuption P consumption temperature ccessories on page 70 pressure Ø lue gas discharge / kw kw min l/min g/s m 3 /h g/h MPa kg (mm) T 220 220 185552 25,0 23,3 32 11,3 12,5 109 2,65 2000 85 0,6 220 100 T 300 300 185553 29,0 27,0 38 13,0 14,0 115 3,07 2300 85 0,6 265 100 T 400 390 185554 29,0 27,0 52 12,6 14,8 97 3,07 2300 85 0,6 309 100 Nota: Room-sealed, fan flue 12 32 42 82 / ategory II 2H3+ / absorbed power : 62W - 230V~ Type Recirculation and discharge as fitting - Z- mm mm mm mm mm mm T 220 Rp ¾ Rp ¾ R ½ 720 1445 405 570 960 1285 T 300 Rp 1 Rp 1 R ½ 720 1795 405 570 960 1640 T 400 Rp 1 Rp 1 R ½ 720 2145 405 570 1135 1985 54

lectric Water Heaters The Styleboiler range of electric storage water heaters offers an extensive array of models for the production of domestic hot water (.H.W.) with a capacity ranging from 10 to 1000 litres and power ratings from 1.2 to 10 kw with single- and three-phase. The range meets both the domestic requirements of a typical home as well as those of industrial and collective settings. The product lines include rapidi models, which are ideal for the rapid and cheap production of small quantities of water, designed for installations where limited space is available, the classic standard models devised to accommodate the essential basic requirements of the market, and also the interline product line, providing a large number of combinations to meet the highest expectations as regards quality in observance of uropean and international standards. The STRNTHS of the product range in detail: Thermal insulation Insulation layer made of very thick (Interlinerange) high-density polyurethane (PU) foam that guarantees excellent insulation. ess heat loss means lower energy waste. Tank protection against wear Thanks to the flow-coating enamelling process at 850 for guaranteed quality internal protection or via classic Tefloncoating. Magnesium anode eatured in all the models in the range, this anode makes for effective electrochemical tank protection. xternal control knob (S) xternal control knob used to facilitate the water heater temperature adjustment, combined with the flange for easy inspection and cleaning. ual safety Thanks to the presence of both an thermostat and a maximum temperature thermostat to avoid possible malfunctions. IP degree of protection Styleboiler water heaters are safe because they are splash-proof and are specially designed for installation close to the water delivery points, even in public and collective settings. nvironmentally friendly We strives to optimise its industrial activity while respecting the environment. To minimise the environmental impact of its products, it has abolished the use of chlorofluorocarbons (-H) in the insulation (PU) layer and makes continuous efforts touse recyclable components. 55

TRI WTR HTRS Rapidi / Rapidi S SRIS PONY 10-15-30 Wall-hung electric storage water heaters are ideal for the rapid and cheap production of small quantities of water. They can be installed above or below the sink (30 itres above only). xternal ontrol Knob Steel tank, glass-lined using the flow-coating method (850 ) orrosion-proof magnesium anode rmoured copper heating element fitted on a 1 ¼ coupling for S version Regulation and safety rod thermostat, with external control knob only for S version IPX5 protective cover over electrical parts Polystyrene insulating shells (PS) for reduced heat loss Shock-resistant polypropylene (PP) casing and back rackets for wall mounting availableupon request indicator light Product with threaded heating element and internal control thermostat Type apacity ode Power Voltage Heating time T=50 temperature pressure / kw V~ min MPa kg - mm mm mm mm mm mm mm Pony 10/2 10 171513 1,2 230 30 75 0,8 6,0 ½ 261 251 450 228 100 62 189 Pony 10/2 s 10 171514 1,2 230 30 75 0,8 6,0 ½ 261 251 450 250 100 62 189 Pony 15/2 15 171515 1,2 230 46 75 0,8 7,5 ½ 296 285 498 248 100 69 216 Pony 15/2 s 15 171516 1,2 230 46 75 0,8 7,5 ½ 296 285 498 270 100 69 216 Pony 30/2 30 171517 1,2 230 92 75 0,8 10,0 ½ 366 355 568 384 100 89 266 Note: s = undersink version. Product with heating element fitted on a inspection flange and external knob Type apacity ode Power Voltage Note: s = undersink version. Heating time T=50 temperature pressure / kw V~ min MPa kg - mm mm mm mm mm mm mm Pony 10 S 10 171557 1,2 230 30 75 0,8 6,0 ½ 261 251 450 228 100 62 189 Pony 10 S s 10 171558 1,2 230 30 75 0,8 6,0 ½ 261 251 450 250 100 62 189 Pony 15 S 15 171559 1,2 230 46 75 0,8 7,5 ½ 296 285 498 248 100 69 216 Pony 15 S s 15 171560 1,2 230 46 75 0,8 7,5 ½ 296 285 498 270 100 69 216 Pony 30/5 S 30 171561 1,2 230 92 75 0,8 10,0 ½ 366 355 568 384 100 89 266 oversink version 10-15-30 undersink version 10-15 K W 56

Standard SRIS V 30 200 and V 30 100 Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. TRI WTR HTRS Steel tank, glass-lined using the flow-coating method (850 ) rmoured copper heating element fitted on a 1 1 4 coupling orrosion-proof magnesium anode Regulation and safety rod thermostat indicator light xternal casing made of sheet metal coated with epoxy powder paint and H- free thick rigid polyurethane (PU) insulation layer IPX4 protective cover over electrical parts Stored water temperature indicator Series V 30 Series V 50-80-100 versione 120 Series V 120 Series versione V 150-200 versione 120 versione 150-200 O 345 366 Ø 450 Ø 450 476 476450 540 450 540 554 476 554 476 540 540 554 5 536 346 295 100 Series V 30 200 Type apacity ode Power Voltage 69 270 100 270 100 125 Heating time T=50 270 431 230 100 125 temperature pressure / kw V~ min MPa kg - mm mm V 30 30 171700 1,2 230 92 75 0,8 12,0 ½ See diagram V 50 50 171701 1,2 230 153 75 0,8 15,1 ½ 511 288 V 80 80 171702 1,2 230 245 75 0,8 21,8 ½ 742 518 V 100 100 171703 1,2 230 306 75 0,8 25,5 ½ 893 670 V 120 120 171521 1,5 230 294 75 0,8 29,0 ½ 795 594 V 150 150 171522 2,0 230 275 75 0,8 42,0 ¾ 945 500 V 200 200 171523 2,0 230 367 75 0,8 51,5 ¾ 1205 800 193 270 431 100 230 193 156 431 112 156 230 112 230 244 431 244 156 240 Series V 30 100 Type apacity ode Power Voltage Heating time T=50 100 temperature pressure / kw V~ min MPa kg - mm mm mm mm mm V 30 30 171748 1,5 230 73 75 0,8 12,0 ½ 475 286 370 396 113 V 50 50 171749 1,5 230 122 75 0,8 15,1 ½ 530 318 450 476 152 V 80 80 171750 1,5 230 196 75 0,8 21,8 ½ 735 515 450 476 152 V 100 100 171751 1,5 230 245 75 0,8 25,5 ½ 880 666 450 476 152 57

TRI WTR HTRS Standard S SRIS V 50 200 S Wall-hung electric storage water heaters are designed to cater for the most varied market requirements. The external control knob (S) makes for easier adjustment of the water temperature. lso recommended for industrial and collective use. Steel tank, glass-lined using the flow-coating method (850 ) 88 mm tank inspection flange orrosion-proof magnesium anode rmoured copper heating element fitted on a flange Regulation and safety rod thermostat with external control knob. and H- free thick rigid polyurethane (PU) insulation layer xternal casing made of sheet metal coated with epoxy powder paint indicator light IPX4 protective cover over electrical parts Stored water temperature indicator Ø 450 Version V 50-80-100 S 476 476 115 125 xternal ontrol Knob 270 Ø 450 100 270 100 125 Type apacity ode Power Voltage Heating time T=50 ^ temperature ^ pressure / kw V~ min MPa kg - mm mm V 50 S 50 185938 1,2 230 153 75 0,8 15,5 ½ 511 288 V 80 S 80 185939 1,2 230 245 75 0,8 20,5 ½ 742 518 V 100 S 100 185940 1,2 230 306 75 0,8 25,5 ½ 893 670 V 120 S 120 171569 1,5 230 294 75 0,8 29,0 ½ 795 594 V 150 S 150 171154 2,0 230 275 75 0,8 42,0 ¾ 945 500 V 200 S 200 171155 2,0 230 367 75 0,8 51,5 ¾ 1205 800 versione Version 120 versione V 120 120 S Version versione V 150-200 S versione 150-200 450 540 450 540 554 476 554 476 540 540 554 554 100 270 431 270 431 230 193 230 100 193 431 156 112 156 230 244 431 112 230 244 156 156 58

Standard Termo SRIS V/T 50 100 and V/T 120 200 Wall-hung electric storage water heaters thermo version are the basic product range devised to cater for the most varied market requirements. The external control knob (S) makes for easier adjustment of the water temperature. Recommended for domestic and collective use. Steel tank, glass-lined using the flow-coating method (850 ) orrosion-proof magnesium anode rmoured copper heating element fitted on a 1 ¼ coupling, on flange only for S version Regulation and safety rod thermostat, with external control knob only for S version indicator light and H- free thick rigid polyurethane (PU) insulation layer IPX4 protective cover over electrical parts Stored water temperature indicator vailable with left or right hydraulic TRI WTR HTRS xternal ontrol Knob Type apacity ode Power Voltage Heating time T=50 Max temperature pressure coil fitting Heat exchange surface / kw V~ min MPa kg - PV-PR m 2 kw l/h m 3 /h V/T 50 X/SX 50 185941 1,2 230 153 75 0,8 17,0 ½ Rp ½ 0,16 6,5 170 1,0 V/T 80 X/SX 80 185942 1,2 230 245 75 0,8 23,5 ½ Rp ½ 0,20 7,7 190 1,0 V/T 100 X/SX 100 185943 1,2 230 306 75 0,8 27,5 ½ Rp ½ 0,20 7,7 190 1,0 V/T 120 S X V/T 120 S SX V/T 150 S X V/T 150 S SX V/T 200 S X V/T 200 S SX 120 150 200 171573 171574 171575 171576 171577 171578 Power ( T 35K) **.H.W. ( T 35K) ** 1,5 230 294 75 0,8 37,0 ½ Rp ½ 0,6 19,0 469 2,0 2,0 230 275 75 0,8 56,5 ¾ Rp ½ 0,9 33,0 810 2,0 2,0 230 367 75 0,8 66,0 ½ Rp ½ 0,9 33,0 810 2,0 ** Note : Primary circuit temperature 80 / Secondary circuit temperature 10/45 / Primary flow rate indicated in the table /.H.W. = production of domestic hot water Primary flow rate Type mm mm mm mm V/T 50 X/SX 511 288 220 107 V/T 80 X/SX 742 518 220 338 V/T 100 X/SX 893 670 220 352 V/T 120 S X V/T 120 S SX V/T 150 S X V/T 150 S SX V/T 200 S X V/T 200 S SX 605 1029 see diagram 945 500 see diagram 1205 800 see diagram PV PV PR PR Version versione 120 Version versione 150/200 540 450 270 431 230 100 554 476 PV PV PR PR 156 Ø 450 Version 50-80-100 476 PV PV 476 115 125 270 PR PR 241 250 231 250 193 241 450 540 PV 431 PR 112 230 244 554 PV PR 156 Ø 450 100 270 100 125 59

TRI WTR HTRS PV PV S PR R S PR R H H R R S Vertical Wall-hung SRIS V/TS 80 200 Solar Thermal ready Type apacity ode Power Power supply lectric water heaters with increased heat exchanger suitable for solar application, are the basic product range devised to cater the most varied market requirements. Suitable for collective use. Steel tank, glass-lined using the flow-coating method (850 ) orrosion-proof magnesium anode High performance coil Regulation and safety rod thermostat Indicator light xternal casing made of steel shee metal coated with epoxy powderpaint and H-free very thick polyurethane (PU) foam insulation layer IPX4 protective cover over electrical parts. Stored water temperature indicator vailable with left or right hydraulic rmored copper heating element fitted on a Ø 88 mm flange with solar sensor sheath included Heating time ( T 50 ) temperature pressure Primary flow rate Heat exchange surface / kw V~ min MPa kg m 3 /h m 2 /kw V/TS 80 X SX 80 185947 1,5 230 23 00 95 0,8 28,5 2,0 0,6/20 V/TS 100 X SX 100 185948 1,5 230 29 00 95 0,8 33,5 2,0 0,6/20 V/TS 120 X V/TS 120 SX V/TS 150 X V/TS 150 SX V/TS 200 X V/TS 200 SX Type 120 150 200 185715 185716 185717 185718 185719 185720 Note: Version without heating element, upon request 1,5 230 34 00 95 0,8 37,0 2,0 0,6/20 2,0 230 30 00 95 0,8 56,0 3,0 0,9/30 2,0 230 40 00 95 0,8 65,5 3,0 0,9/30 H M R S - PV-PR mm mm mm mm mm mm mm mm mm mm mm mm V/TS 80 X SX ½ Rp ½ 178 340 219 476 450 270 380 100 125 115 338 742 V/TS 100 X SX ½ Rp ½ 178 491 219 476 450 270 380 100 125 115 338 893 V/TS 120 X SX ¾ Rp ½ 594-241 555 540 431 486 230 156 118 248 795 V/TS 150 X SX ¾ Rp ½ 243 500 241 555 540 431 486 230 156 118 450 945 V/TS 200 X SX ¾ Rp ½ 243 800 241 555 540 431 486 230 156 118 450 1205 Version 80/100 Version 120 Version 150/200 H M M S R M 60

480 480 50-80-100-120 50-80-100-120 150/200 TRI WTR HTRS Horizontal / Horizontal termo SRIS O 50 200 and O/T 80-100 Wall-hung electric storage water heaters are the basic product range devised to cater for the most varied market requirements. Steel tank, glass-lined using the flow-coating method (850 ) Ø 88 mm tank inspection flange orrosion-proof magnesium anode rmoured copper heating element fitted on a flange Regulation and safety rod thermostat 50-80-100-120 150-200 xternal casing made of sheet metal coated with epoxy powder paint IPX4 protective cover over electrical parts and H- free thick rigid polyurethane (PU) insulation layer indicator light Stored water temperature indicator Ø 450 Ø 450 347 347 450 481 570 120 120 240 240 Horizontal O 50 X O 50 SX O 80 X O 80 SX Type apacity ode Power Voltage O 100 X O 100 SX O 120 X O 120 SX 50 80 100 120 171714 171715 171716 171717 171718 171719 171550 171551 PV Heating time ( T 50 ) 481 temperature pressure kw V~ min MPa kg - mm mm mm mm 1,2 230 153 75 0,8 15,5 ½ 1,2 230 245 75 0,8 20,5 ½ 1,2 230 306 75 0,8 25,5 ½ 1,2 230 367 75 0,8 29,0 ½ O 150 X SX 150 171552 2,0 230 275 75 0,8 65,5 ¾ 1024 530 444 256 O 200 X SX 200 171553 2,0 230 367 75 0,8 71,5 ¾ 1294 800 238 256 80-100 Termo 526 526 757 757 908 908 1005 1005 191 191 258 258 409 409 506 506 178 228 293 344 369 419 467 418 228 178 344 293 419 369 418 467 Ø 450 PR 200 140 362 120 245 Horizontal Termo Type apacity ode Power Voltage O/T 80 X O/T 80 SX O/T 100 X O/T 100 SX Heating time T=50 temperature pressure Heat xchange fitting / kw V~ min MPa kg - PV-PR mm mm mm mm 80 100 171759 171580 171581 171582 1,2 230 245 75 0,8 26,5 ½ Rp ½ 807 370,5 316,5 220 1,2 230 306 75 0,8 31,6 ½ Rp ½ 930 418,5 391,5 370 61

TRI WTR HTRS Interline SRIS ISS 120 1000 loor-standing electric storage water heaters are designed to meet the highest expectations as regards quality in observance of uropean and international standards. The insulation layer is made of very thick high-density polyurethane (PU) foam to minimise heat loss. They are ideal for collective and industrial use. Steel tank, glass-lined using the flow-coating method (850 ) Ø 134 mm frontal inspection hatch (Type120 600) 2 x 134 mm frontal inspection hatch (Type 800-1000) orrosion-proof magnesium anode rmoured copper heating element fitted on the hatch Regulation and safety rod thermostat or 800-1000 version double electrical kit 10 kw each with total power of 20 kw and H-free very thick polyurethane (PU) foam insulation layer asy entry systems plus (PS) for series 800-1000 IPX5 protective cover over electrical parts Stored water temperature indicator. djustable feet for floor standing xternal soft plastic coating (PV), white R 9016 w SVW SSI Type apacity ode Power Voltage Heating time T=50 Heat loss N 12897 Insul. thickness temperature pressure 1 / 2 ccessories on page 66-67-68 / kw V~ min kwh/24h mm MPa kg --Z mm mm mm mm mm mm ISS 120 120 185610 1,5 230 294 1,0 50 95 0,6/1,2 38 Rp ¾ 610 620 854 150 486 720 ISS 160 160 185611 2,0 230 294 1,7 50 95 0,6/1,2 46 Rp ¾ 610 620 1056 150 551 922 ISS 200 200 185612 2,0 230 367 2,0 50 95 0,6/1,2 53 Rp ¾ 610 620 1329 150 651 1195 ISS 300 300 185613 3,0 230 367 2,5 50 95 0,6/1,2 77 Rp 1 650 675 1560 148 828 1408 ISS 300/3 300 185614 3,0 400/3 367 2,5 50 95 0,6/1,2 77 Rp 1 650 675 1560 148 828 1408 ISS 400/3 400 185615 4,0 400/3 367 2,9 50 95 0,6/1,2 99 Rp 1 750 775 1553 162 782 1387 ISS 500/3 500 185616 5,0 400/3 367 3,3 50 95 0,6/1,2 115 Rp 1 750 775 1818 162 932 1652 ISS 600/3 600 185617 5,0 400/3 440 2,9 50 95 0,6/1,2 176 Rp 1 810 832 1819 124 871 1659 ISS 800/3 800 185618 8,0 400/3 367 4,6 50 95 0,6/1,2 220 Rp 1 ¼ 880 925 1865 191 1071 1676 ISS 1000/3 1000 185619 10,0 400/3 367 5,0 50 95 0,6/1,2 250 Rp 1 ¼ 880 925 2245 191 1263 2056 Note : 1 pressure, 2 pressure test according to N 12897 P.4.4.1 asy ntry Systems on 800-1000 Z 62

Interline Inox SRIS ISSX 120 500 and ISSX 800-1000 Stainless steel floor-standing electric storage water heaters are designed to meet the new expectations as to durability and perfection. To this end, the inox (stainless steel) product line was introduced, providing maximum quality and durability owing to the use of special materials such as stainless steel and sophisticated technological solutions such as TI and Plasma welding. The insulation layer is made of very thick high-density polyurethane (PU) foam to minimise heat loss. They are ideal for collective and industrial use. TRI WTR HTRS ISI 316 stainless steel tank welded with TI and Plasma technology Ø 100x150 mm frontal inspectionhatch (Type 120 200) Ø 134 mm frontal inspection hatch (Type 300 600) 2 x 134 mm frontal inspection hatch (Type 800-1000) orrosion-proof magnesium anode series120 500 TRONI TITNIUM NO (800-1000) Stainless steel heating element 230V.~ and 400/3V. Regulation and safety rod thermostat and H-free very thick polyurethane (PU) foam insulation layer asy ntry Systems on800-1000 xternal soft plastic coating (PV), gray R 9006 djustable feet for floor standingstored water temperature indicator or 800-1000 version double electrical kit 10 kw each with total power of 20 kw INOX heating element ccessories on page 66-67-68 Type apacity ode Power Ø SRIS ISSX Voltage Heating time T=50 Heat loss N 12897 Insul. thickness temperature pressure 1 / 2 SRIS ISSX / kw V~ min kwh/24h mm MPa kg --Z mm mm mm mm mm mm ISSX 120 120 185881 1,5 230 294 1,5 50 95 1,0/2,0 26 Rp ¾ 550 571 924 203 463 728 ISSX 160 160 185882 2,0 230 294 1,7 50 95 1,0/2,0 32 Rp ¾ 550 571 1174 203 591 978 ISSX 200 200 185883 2,0 230 367 2,0 50 95 1,0/2,0 35 Rp ¾ 550 571 1524 203 729 1328 ISSX 300/3 300 185779 4,0 400/3 275 2,4 50 95 0,6/1,2 69 Rp 1 650 698 1526 228 803 1283 ISSX 400/3 400 185780 8,0 400/3 184 2,8 50 95 0,6/1,2 74 Rp 1 750 798 1530 263 763 1248 ISSX 500/3 500 185781 10,0 400/3 184 3,3 50 95 0,6/1,2 84 Rp 1 750 798 1796 263 913 1513 ISSX 800/3 800 185548 8,0 400/3 367 4,6 50 95 0,6/1,2 146 Rp 1 ½ 880 925 1865 320 982 1580 ISSX 1000/3 1000 185549 10,0 400/3 367 5,0 50 95 0,6/1,2 170 Rp 1 ½ 880 925 2245 320 1165 1960 Note : 1 pressure, 2 pressure test according to N 12897 P.4.4.1 asy ntry Systems on 800-1000 Z Z 63

Wood ired Water Heaters WOO IR WTR HTRS Wood is a renewable source of energy that may be regenerated continuously. With a rational and sustainable use of forest areas, an immense mass of energy may be supplied which derives indirectly from the sun. We have come up with an appliance that fully exploits the natural energy released by wood, using a water jacket collar on the flue of a fire heater, it is a traditional way of heating water and is extremely effective. Using a wood fired water heaters, alone or combined, means having heat available at a low cost and in an environmentally friendly way, it is an easy and inexpensive possibility to make a noticeable dent in your utility bill, available in both for only wood SRIS, either in version combi wood-electric SRIS or, SRIS /T the only model where solar hot water system and wood fired water heaters can be connected together to provide substantial savings on your annual hot water running costs. The STRNTHS of the product range in detail: Tank protection against wear Thanks to the flow-coating enamelling process at 850 for guaranteed quality. Magnesium anode eatured in all the models in the range, this anode makes for effective electrochemical tank protection. nvironmentally friendly We strive to optimise its industrial activity while respecting the environment. To minimise the environmental impact of its products, it has abolished the use of chlorofluorocarbons (-H) in the insulation layer and makes continuous efforts to use recyclable components. 64

WOO IR WTR HTRS Wood-fired SRIS, and /T Wood-fired storage water heaters are designed to produce water where traditional sources of energy are unavailable or simply to use renewable forms of energy while respecting the environment. lectric or thermo-electric versions are available. Steel tank, glass-lined using the flow-coating method (850 ) orrosion-proof magnesium anode ombustion chamber made of refractory material with pull-out ash collecting device namelled sheet metal external combustion chamber coating Mineral wool insulation layer for reduced heat loss rmoured copper heating element, regulation and safety rod thermostat (wood-electric version only) xternal casing made of sheet metal coated with epoxy powder paint Stored water temperature indicator lectric and thermo-electric versions available /T Type apacity ode Power Voltage Heating time T=50 temperature pressure Heat exchange fitting / kw V~ min MPa kg K PV-PR 80 161170 - - - 90 0,8 46 ½ - 80 161172 1,2 230 245 90 0,8 46 ½ - /T 80 161174 1,2 230 245 90 0,8 49 ½ Rp ¾ Note: = wood-fired version / = wood-electric version / /T = thermo-electric wood version wood-fired version / wood-electric version 360 89 360 100 82 100 thermo-electric wood version 82 89 PV 1468 1468 613 450 PR 65

SSORIS ccessories & kit for electric water heater, indirect and buffer cylinders O SRIPTION SRIS: ISSW 120 600 ISS 200 600 MS 120 300 071037 2,0 kw 230V~ TRI KIT including: 1 ¼ coupling, seal, back up armoured copper heating element and thermostat (safety and regulation), to be installed on the side threaded inlet. 071038 3,0 kw 230V~ TRI KIT including: 1 ¼ coupling, seal, back up armoured copper heating element and thermostat (safety and regulation), to be installed on the side threaded inlet. SRIS: ISSW 120 600 ISS 200 600 ISSWH 300-400-500 ISSWP 300 600 ISSP 500 600 ISS 120 600 070265 2,0 kw 230V~ TRI KIT including: counter flange with 1 ¼ coupling, seal, armoured copper heating element and thermostat (safety and regulation). 070266 3,0 kw 230V~ TRI KIT including: counter flange with 1 ¼ coupling, seal, armoured copper heating element and thermostat (safety and regulation). SRIS: ISSW 120 600 ISS 200 600 ISSWH 300-400-500 ISSWP 300 600 ISSP 500 600 ISS 120 600 070267 3,0 kw 400/3V~ TRI KIT including: counter flange with 2 coupling, seal, armoured copper heating element, complete thermostat (safety and regulation) with brackets and connectors. 070268 4,0 kw 400/3V~ TRI KIT including: counter flange with 2 coupling, seal, armoured copper heating element, complete thermostat (safety and regulation) with brackets and connectors. 070269 5,0 kw 400/3V~ TRI KIT including: counter flange with 2 coupling, seal, armoured copper heating element, complete thermostat (safety and regulation) with brackets and connectors. SRIS: ISSW 1500-2000 ISS 1500-2000 SRIS: ISSWX 120 500 ISSX 200 500 071335 6,0 kw 400/3V~ STINSS ST TRI KIT including: counter flange Ø 180, backup armoured Incoloy 800 stainless and steel heating element, thermostat (safety and external regulation). 071336 12,0 kw 400/3V~ STINSS ST TRI KIT including: counter flange Ø 180, backup armoured Incoloy 800 stainless and steel heating element, thermostat (safety and external regulation). 071337 15,0 kw 400/3V~ STINSS ST TRI KIT including: counter flange Ø 180, backup armoured Incoloy 800 stainless and steel heating element, thermostat (safety and external regulation). 071185 2,0 kw 230 V~ STINSS ST TRI KIT including: ISI 321 stainless steel heating element on 1 ½ coupling, gasket, safety and regulation thermostat (safety and regulation), electric cable and shuko plug, to be installed on the frontal threaded inlet. 071186 3,0 kw 230 V~ STINSS ST TRI KIT including: ISI 321 stainless steel heating element on 1 ½ coupling, gasket, safety and regulation thermostat (safety and regulation), electric cable and shuko plug, to be installed on the frontal threaded inlet. 66

SSORIS ccessories & kit for electric water heater, indirect and buffer cylinders O SRIPTION SRIS: ISSW 120 1000 ISS 200 1000 ISSWH 300-400-500 ISSWP 300 1000 ISSP 500 1000 ISSWX 800-1000 ISSX 800-1000 ISS 120 1000 ISSX 300 1000 070137 3,0 6,0 kw 400/3V ~STINSS ST TRI KIT including: counter flange, seal, incoloy 800 stainless steel three-part heating element, thermostat and supporting bracket. 070138 4,0 8,0 kw 400/3V ~STINSS ST TRI KIT including: counter flange, seal, incoloy 800 stainless steel three-part heating element, thermostat and supporting bracket. 070136 5,0 10,0 kw 400/3V ~ STINSS ST TRI KIT including: counter flange, seal, incoloy 800 stainless steel three-part heating element, thermostat and supporting bracket. SRIS: ISSX 120-160-200 ISSWX 120 500 ISSX 200 500 SRIS: ISPHSO 200 2000 ISPHSW 600 2000 ISPHS 600 2000 PTSW 600 2000 PTS 600 2000 071331 1,5 kw 230V ~ STINSS ST TRI KIT including: counter flange, backup armoured Incoloy 800 stainless and steel heating element, thermostat (safety and external regulation). OR SRIS ISSXW 120 N ISSX 120 071332 2,0 kw 230V ~ STINSS ST TRI KIT including: counter flange, backup armoured Incoloy 800 stainless and steel heating element, thermostat (safety and external regulation). OR SRIS ISSWX 160-200, ISSX 200 N ISSX 160-200 071334 3,0 kw 230V ~STINSS ST TRI KIT including: counter flange, backup armoured Incoloy 800 stainless and steel heating element, thermostat (safety and external regulation). OR SRIS ISSWX 300-400-500 N ISSX 300-400-500 071000 3,0 kw 400/3 V~ STINSS ST TRI KIT including: INOOY 825 stainless steel heating element on 1 ½ coupling, gasket, safety and external regulation thermostat, electric cable, to be installed on the frontal threaded inlet. OR SRIS 071001 6,0 kw 400/3 V~STINSS ST TRI KIT including: INOOY 825 stainless steel heating element on 1 ½ coupling, gasket, safety and external regulation thermostat, electric cable, to be installed on the frontal threaded inlet. OR 400 600 071002 9,0 kw 400/3 V~ STINSS ST TRI KIT including: INOOY 825 stainless steel heating element on 1 ½ coupling, gasket, safety and external regulation thermostat, electric cable, to be installed on the frontal threaded inlet. OR 800 2000 67

SSORIS ccessories & kit for electric water heater, indirect and buffer cylinders O SRIPTION SRIS: ISSW 120 1000 ISS 200 1000 ISSWH 300-400-500 ISSWP 300 1000 ISSP 500 1000 ISS 120 1000 030528 1,0 mq SPIR HT XHNR KIT including: counter flange, 1mq tinned copper finned coil, seal, set of fittings, round cover plate, fastening screws and nuts. OR SRIS 030525 1,8 mq SPIR HT XHNR KIT including: counter flange, 1mq tinned copper finned coil, seal, set of fittings, round cover plate, fastening screws and nuts. OR SRIS SRIS: ISSWX 120 500 ISSX 200 500 ISSX 120 500 080294 TRONI NO KIT including: Titanium rod, 1 ½ threaded plug, O-ring, plastic cover, control box and power cable. ynamic system for the active protection against corrosion SRIS: ISSWX 120 500 ISSX 200 500 071172 THRMOSTT PRIORITY KIT including: plastic printed hatch cover, regulation thermostat (max T 63 ), cables and terminal. 68

SSORIS ccessories & kit for heat pumps O SRIPTION SRIS: HP 180-300 HP 180W-300W-300 145053 IR OUTT KIT The kit includes: black PST air conveyor, conveyor fastening system, aluminium rings for Ø160 mm pipe fastening, instructions, package 145066 IR INT KIT The kit includes: black PST air conveyor, conveyor fastening system, aluminium rings for Ø 160 mm pipe fastening, instructions, package. O SRIPTION SRIS: UTUR 200-250-300 UTUR 200-250-300 W UTUR 250-300 UTUR 210-270-315 X UTUR 210-270-315 WX UTUR 270-315 X 145131 PP dapter Ø 190/210 145132 PP duct extension Ø 180 lenght 500 mm 145133 PP duct extension Ø 180 lenght 1000 mm 145134 lbow 45 PP Ø 180 145135 lbow 90 PP Ø 180 69

SSORIS ccessories & kit for gas water heaters O SRIPTION SRIS: T 220-300-400 140450 Ø 60/100 mm OXI HORIZONT ISHR KIT 140456 Ø 60/100 mm coaxial extension = 500 M/ 140457 Ø 60/100 mm coaxial extension = 1000 M/ 140458 Ø 60/100 mm 45 coaxial elbow 140459 Ø 60/100 mm 90 coaxial elbow 140452 Ø 60/100 mm OXI VR TI ISHR KIT 140456 Ø 60/100 mm coaxial extension = 500 M/ 140457 Ø 60/100 mm coaxial extension = 1000 M/ 140451 Ø 80-80 mm SPIT ISHR KIT 140460 Ø 80 mm extension -= 250 M/ 140461 Ø 80 mm extension -= 500 M/ 140462 Ø 80 mm extension -= 1000 M/ 140463 Ø 80 mm 45 elbow M/ with gasket 140464 Ø 80 mm 90 elbow M/ with gasket 70

eneral remarks ll STYOIR appliances conform to uropean irectives. The gas appliances are devised and specifically approved for the use of standard fuels. ll STYOIR appliances made at the S.Maria di Zevio (VR) plant are designed and built in compliance with international quality standards ISO 9001/2008 and conform to article 3.3 of uropean irective 97/23/ (P). Installation and use These appliances are approved for indoor installation only. Installation must be performed and certified by authorised technicians only, in accordance with the law. hydraulic safety group compliant with N 1487 or the equivalent must be fitted on all appliances. The water temperature adjustment allows the energy consumption to be optimised according to the well-being required. However, it is advisable to prevent the temperature of the water stored from being too low, in order to avoid the proliferation of bacteria that cause egionnaire s disease. To this end, here are a few general precautions to take: Keep the hot water inside the appliance at a temperature of no less than 50 ; In the event of prolonged absences, allow water to run freely from taps and showers for a few minutes; Keep shower heads and taps free of limescale build-ups. The manufacturer cannot be responsible for the damages caused by improper installation or by failure to follow instructions in this pamphlet. omply with the installation instructions before completing electric connection. Technical characteristics s STYOIR constantly strives to improve its products, the company reserves the right to make changes to the technical characteristics and to discontinue models illustrated in this catalogue without prior notice. The details are purely indicative and are included to help you choose the right appliance for your needs. In addition, the manufacturer denies all responsibility in the event of printing or transcription errors. ertification and Quality Marks The company works in cooperation with major certifying bodies to attest the quality of the products and production processes. w uarantee SVW SSI STYOIR guarantees the correct operation of its appliances according to the methods stated on the guarantee certificates included with the appliances and always in compliance with the applicable aws in force. 71