DIVISION 22: PLUMBING DESIGN STANDARDS TABLE OF CONTENTS

Similar documents
BSD Technical Standard. Division 22: Plumbing

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

DOMESTIC WATER PACKAGED BOOSTER PUMPS

PLUMBING DESIGN GUIDELINES SECTION DESIGN GUIDELINES DUVAL COUNTY PUBLIC SCHOOLS

Mechanical Inspection Plumbing

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

SECTION PLUMBING

GARCIA GALUSKA DESOUSA Consulting Engineers

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Union County Vocational - Technical Schools Scotch Plains, New Jersey

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

2. All necessary storm and sanitary pumps shall be tied into emergency power, and sump levels shall be monitored electronically through the B.A.S.

A. This Section includes the following domestic water piping specialties:

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

DESIGN GUIDELINES AND TECHNICAL STANDARDS

2016 Plumbing Supplemental Plan Review List

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

GENERAL PLUMBING REQUIREMENTS

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015

HWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

SECTION DOMESTIC WATER PIPING SPECIALTIES

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

WARRANTY POLICY & RECOMMENDED MAINTENANCE

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

University of Rochester October 17, 2008 Brooks Landing Business Center

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

SECTION PLUMBING FIXTURES AND TRIM. A. Types of plumbing fixtures required for the project include the following:

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance

GENERAL PLUMBING REQUIREMENTS

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

AIRPORT PLUMBING DESIGN STANDARDS REV. 3 3/18/2016

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

DIVISION 21 - FIRE SUPPRESSION

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

A. General: comply with appropriate standards. 1. International Association of Plumbing and Mechanical Officials: IAPMO. 2. California State AB 1953.

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

Read Only Document Not For Distribution

A. Section Joint Sealants: Seal fixtures to walls and floors.

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

State College Area School District High School North Building EXISTING CONDITIONS ASSESSMENT

B. Provide unique numbers for all applicable equipment, valves, and similar.

1. Division 22 Section "Emergency Plumbing Fixtures." 2. Division 22 Section "Drinking Fountains and Water Coolers."

2). Crane Co. 4). Kohler Co. 5). Universal-Rundle Corp. Revised September 29, 2017 Commercial Plumbing Fixtures

TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

Test Code: 8117 / Version 1

plumbing for greywater

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

University of New Hampshire Scholars' Repository

Special Requirements For Health Care Facilities

Read Only Document Not For Distribution

Design & Construction Standards, Revised January

FIRE SUPPRESSION SPRINKLER SYSTEM

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01

SECTION WET-PIPE SPRINKLER SYSTEMS

PLUMBING INSTALLATIONS

Yale University Design Standards

Level I Chapter 1 Worksheet

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Plumbing Standards

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

Plumbing Technology/Plumber CIP Task Grid

B. Related Sections: The following Sections contain requirements that relate to this Section.

2. Welding Materials and Procedures shall conform to the ASME Code.

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010

SPRINKLERS TABLE OF CONTENTS

ADDENDUM NO. 3 March 19, 2018

DIVISION 21 - FIRE SUPPRESSION

1 Exam Prep Plumbing State Contractors Practice Exam 2

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION WATER TREATMENT

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

Building Utilities 1 Plumbing and Sanitary Systems

A. This Section includes the following emergency plumbing fixtures:

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

SCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

Plumbing and Drainage

Mechanical System Description

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

SECTION HYDRONIC PIPING AND SPECIALTIES

PLUMBING REQUIREMENTS

SECTION PLUMBING FIXTURES

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

Read Only Document Not For Distribution

MATERIALS Traps TRAPS. No. IPC IRC Description

DESIGN CRITERIA See Part II for additional information regarding Energy and Water Efficiency, etc.

CHAPTER 10 TRAPS AND INTERCEPTORS

NATURAL GAS PIPING

Denotes a new question! Denotes a revised/revisited question. September 2009 General:

Transcription:

DIVISION 22: PLUMBING DESIGN STANDARDS TABLE OF CONTENTS I. PURPOSE II. III. IV. GENERAL A. DESIGN DOCUMENTS B. INSPECTIONS C. CLOSE-OUT Project Record Documentation Training D. ENERGY USE E. LABELING F. QUALITY OF MATERIAL G. PIPING DEMO, REMODELS, AND RE-PIPES PIPING SYSTEMS A. FITTINGS B. SUPPORTS C. VACUMM BREAKERS D. DISSIMILAR METALS E. COPPER F. GALVANIZED STEEL G. BLACK IRON H. EXPANSION JOINTS I. WIRSBO AND PEX J. DRAIN AND WASTE PIPING Clean Outs Trap Primers Laboratory Piping Grease Traps and Interceptors K. PIPING SCHEDULE VALVES A. SPECIFIC VALVE TYPES Gate Valves Globe Valves Ball Valves Butterfly Valves Backflow/Check Pressure Reducing Valve (PRV) Backwater Valve (Backflow Preventer) Emergency Gas Shut-Off B. VALVE SCHEDULE BSD Division 22: Plumbing Design Standards Revised: 12/10/2009 Page 1 of 11

DIVISION 22: PLUMBING DESIGN STANDARDS TABLE OF CONTENTS V. FIXTURES/CHROME, VITREOUS CHINA A. FAUCETS AND FLUSH-O-METERS Electronics Flush-o-meters Faucets and Shower Valves Faucet Schedule B. VITREOUS CHINA Lavatories Classroom Sinks Water Closets and Urinals VI. VII. VIII. DOMESTIC HOT WATER SYSTEM KITCHEN A. KITCHEN SPRAYERS AND HOSES B. GARBAGE DISPOSALS C. HANDWASHING SINKS D. FOOD PREPARATION SINKS E. FLOOR SINKS F. STEAM OVENS AND STEAM KETTLES G. DISHWASHERS H. DISHWASHER BOOSTER HEATERS MISCELLANEOUS A. DRINKING FOUNTAINS B. EYE WASH C. CAN WASH BSD Division 22: Plumbing Design Standards Revised: 12/10/2009 Page 2 of 11

DIVISION 22: PLUMBING DESIGN STANDARDS I. PURPOSE This document is a narrative describing Beaverton School District s (BSD) Basis of Design for mechanical plumbing systems. The information contained herein shall be used by the Project Design Team to develop a sustainable, integrated mechanical system that is economical to maintain and operate and that enhances learning by providing a suitable work environment for staff and students. This document shall be used as part of the District s Construction Design Standards. II. GENERAL A. DESIGN DOCUMENTS The Project Design Team shall provide to the BSD, as part of all Design Document Submittals, a narrative with detailed descriptions of system features, functionality, limitations, design assumptions, and parameters. The narrative shall be provided as a deliverable with the Schematic Design, and be updated with each subsequent design delivery including Design Development (DD) and Construction Document (CD) Phases. The narrative shall be detailed enough to provide necessary and beneficial information to future design teams, and be written in a manner that is informative and useful to building operations personnel. In its final form, this document shall be incorporated into the Construction Documents and placed on the first sheet of the Plumbing Drawings. Drawings shall contain all equipment schedules. As-built drawings shall include valve and pipe schedules. The Design Team is responsible for obtaining room numbering assignments from the District. If room numbers other than Districtassigned numbers are initially used on the drawings, final as-built documentation must cross-reference these room number assignments on the drawings. Design assumptions that define the capabilities of the building shall be documented on the drawings. These include, but are not limited to, natural gas calculations, water service calculations, sewer and storm sewer calculations, maximum occupancy, provisions for future expansion (if any). This will ensure that the information is retrievable years later when only the drawings are available to facility operations. The Design Team shall review plumbing designs with District personnel at the completion of Schematic Design, Design Development, and at 95% Construction Documents. B. INSPECTIONS The Owner s Representative and BSD s Maintenance Administrator shall be notified at all under floor, framing, and top out inspections, so that piping routes, valves, connections, and any other pertinent plumbing applications can be verified and documented. C. CLOSE-OUT Project Record Documentation Prior to Owner Acceptance, provide three hard copies and one set of PDF files of operation and maintenance (O&M) manuals to Owner. Submit three hard copies, PDF files, and AutoCAD files of all as-built drawings. BSD Division 22: Plumbing Design Standards Revised: 12/10/2009 Page 3 of 11

The Contractor s red-line drawings will be copied (full scale, color copy) and provided to the Owner at Temporary Occupancy. The copied drawings shall include all approved change order drawings and details. At Project Close-out, the Contractor s red-line drawings, including all approved change order drawings and details, shall be copied and turned over to the Owner. The Contractor will then release the drawings to the Architect for preparation of the Record Set. The Architect will prepare and submit as-built drawings in PDF and in AutoCAD format per Division 1 of BSD s Construction Design Standards which shall include the following to reflect actual constructed conditions: Identify actual location and routing of buried pipes Include additional sheets with all approved change order drawings and details as well as the change order log for reference As-built documentation shall include the following as a minimum: Documentation of all deviations from the shop drawing submittals, including equipment that was changed and the reason for the change Copies of final test reports and any deficiency lists Documentation of all deviations in O&M information from that provided with original equipment submittals Training Provide for training of maintenance and school personnel as detailed below. Video tape complete training session for future use by school personnel. Training shall include a review of the O&M manual, including but not limited to: How to monitor status readouts and history logs of systems Required maintenance Troubleshooting, including contact names and phone numbers for factory support Products making use of technology or materials that are new to the District shall require additional specialized training. D. ENERGY USE All piping and mechanical systems shall meet and/or exceed current Oregon Energy Code. Insulate all hot water, cold water, heating water, and chilled water pipes and unconditioned spaces. Design goals should provide building energy use that would allow easy qualification as an Energy Star rated building. Fixtures that are chosen on the basis of energy saving should provide a 10 years or less payback with anticipated maintenance costs included. The Design Team shall provide Oregon Energy Code Compliance documentation to the owner concurrently with submittal to the building department. Oregon Energy Code Compliance documentation shall be included as a section in the O&M Manual. E. LABELING All piping systems shall be permanently labeled identifying type of fluid and direction of flow. All valves shall be labeled identifying function and valve number as set out in BSD Division 22: Plumbing Design Standards Revised: 12/10/2009 Page 4 of 11

the posted valve schedules. All valves located above the drop ceiling shall be clearly marked on the grid with printed labels. F. QUALITY OF MATERIAL All piping systems shall be designed and installed in a manner that provides the best possible long-term value for the District. Take special care to minimize the effects of electrolysis and corrosion. G. PIPING DEMO, REMODELS, AND RE-PIPES All piping being demolished or abandoned must be removed, along with all resulting construction debris, with the following exceptions: Piping 1 Ø or less may be abandoned in place. Under special circumstances, piping larger than 1 Ø may be abandoned in walls (requires Owner approval). Underground piping and piping in slabs may be capped and abandoned in place. Piping in tunnels: If tunnel is being sealed off and abandoned, then piping may be abandoned in place. However, if tunnel is being reused or still being used (contains active pipes, conduit, or duct work), then demolished piping larger than 1 Ø must be removed from tunnel and all construction debris removed. III. PIPING SYSTEMS A. FITTINGS No field manufactured. No Tee pulling. B. SUPPORTS All piping must be supported per code. Double nut required on all threaded hangers. C. VACUUM BREAKERS Vacuum breakers shall not be installed in walls or in recessed cabinets. Overflow from vacuum breakers located inside the building must flow directly to a drain. D. DISSIMILAR METALS Minimum of 6 long, brass fitting shall be used between dissimilar metals. Use of dielectric unions is not acceptable in domestic water systems, with the following exceptions: Use 3/4"Ø dielectric copper flex connector for water heater connections Use 6 long, brass fitting, brass valve, or dielectric where necessary in hydronic piping systems. E. COPPER Type L or better. Use sweat or brazed. Grooved with BSD approval on a case-by-case basis. F. GALVANIZED STEEL Galvanized pipe and are unacceptable for domestic water use on District Projects. Acceptable for dry pipe systems, waste connections, or for use as sleeves. BSD Division 22: Plumbing Design Standards Revised: 12/10/2009 Page 5 of 11

G. Black Iron Use of black iron pipe is acceptable for the following two applications: Natural Gas piping Fire Protection Sprinkler : Groove-lock or Victaulic-type connectors are acceptable for use in wet fire sprinkler systems. This is the only allowed use of steel or iron groove-type on District Projects. H. EXPANSION JOINTS Use where vibration or expansion is a concern. Braided stainless steel only. I. WIRSBO AND PEX WIRSBO and PEX piping systems require written permission from BSD s Maintenance Department Administrator prior to 100% Design Development phase of Project. Use of PEX up to 1 Ø is allowable for branch lines. Any use of PEX greater than 1 Ø must be approved by BSD prior to release of Construction Documents (bid set). Use of PEX requires connection details to be included in the Construction Documents. Details shall be provided showing transitions, manifolds, hangers, supports, connections, and attachments. PEX piping in locations not shown in Construction Drawings (Bid Set) shall not be allowed. J. Drain and Waste Piping Use ABS for all buried waste lines and all vent pipes. Cast iron pipe is to be used above ground only. Cast iron applications include noise suppression on waste piping stacks between floors and for upper floors. Fittings for each are as follows: ABS: Glued only Cast iron: Hubless (no-hub) only Clean outs: Drain lines under 3"Ø, including floor sinks and floor drains, must have an accessible clean out. Trap Primers: For single trap application, use Precision Plumbing Products P-1 or P-2 primers connected to flush-o-meters. For a bank of traps, exceeding four traps, use electronic trap primer. Connection of trap primer to DDC system will not be accepted. Laboratory Piping : Acid resistant piping and neutralization basins as required by code. Tank opening must be located outside of the building and be easily accessible for clean out. Grease Traps and Interceptors: Only as required by code. Tank opening must be located outside of the building and be easily accessible for clean out. BSD Division 22: Plumbing Design Standards Revised: 12/10/2009 Page 6 of 11

K. PIPING SCHEDULE Service Size Location Material Hydronic and Chilled Water Potable Water (Hot and Cold Water) Through 2 Ø All copper-type L or better, soldered 2-1/2 Ø All copper-type L or better, brazed 3 Ø and All black steel w/ welded or flanged larger Through 2 Ø All copper-type L or better, soldered 2-1/2 Ø and All copper-type L or better, brazed larger 1" Ø or smaller Requires written case by case approval PEX or WIRSBO, brass or copper manifolds and Drain and Waste Natural Gas Fire Sprinkler Joining Dissimilar Metals All All no galvanized for potable All, except waste ABS, glued stacks between floors Above ground only: between floors for noise suppression cast iron, hubless, no Bell & Spigot 1-1/4 to 3 Waste connection galvanized is permissible Through 2 Ø No threaded gas pipe greater than 2 psi inside of building 2-1/2 Ø and larger All Wet systems only black steel w/ threaded or welded black steel w/ welded or flanged copper type L or better, soldered, or black steel w/ threaded or welded copper type L or better, or black steel w/ grooved or Victaulic galvanized steel w/ threaded or black steel w/ welded Dry systems: case by case approval All potable All potable NO dielectric unions ¾ Water heaters water heater connections use ¾ Ø dielectric copper flex connector FIP nut x FIP nut. All All other Use 6 minimum length brass nipple or fitting for dielectric protection when joining dissimilar metals. Hydronic Hydronic Use 6 minimum length brass nipple or dielectric fitting for dielectric protection when joining dissimilar metals. BSD Division 22: Plumbing Design Standards Revised: 12/10/2009 Page 7 of 11

IV. VALVES Provide adequate shut-off valves for service isolation. Isolation valves will be available for each plumbing branch and on both sides of any equipment. A. SPECIFIC VALVE TYPES Gate Valves: For steam systems only. No gate valves for potable water or hydronic systems (unless required by state boiler code). Globe Valves: No globe valves in domestic water systems. Ball Valves: Full-port bronze. Use for isolation, shut-off, drains, and throttling. Butterfly Valves: 3"Ø and larger, shut-off and throttling. Backflow/Check: Must be able to be disassembled for maintenance without breaking the line. Below 2 Ø, FEBCO only; 2-1/2 Ø and larger, FEBCO or Watts. Pressure Reducing Valve (PRV): Watts, or equal. Backwater Valve (Backflow Preventer): For sanitary and storm sewer, when needed. Emergency Gas Shut-Off: NFPA rated. B. VALVE SCHEDULE System Service Valve Type Size Material Hydronic and shut-off, throttling, ball, full-port All bronze Chilled Water drain shut-off, throttling butterfly 3 Ø or cast iron or bronze larger throttling globe All bronze Potable Water (Hot and Cold Water) Steam Drain and Waste Natural Gas Fire Sprinkler shut-off, throttling, ball, full-port All bronze drain shut-off, throttling butterfly 3 Ø or cast iron or bronze larger backflow double check FEBCO only PRV Watts or equal backflow preventer when needed shut-off emergency shut-off shut-off, drain Gate or other steam rated valve ball ball BSD Division 22: Plumbing Design Standards Revised: 12/10/2009 Page 8 of 11

V. FIXTURES/CHROME, VITREOUS CHINA A. FAUCETS AND FLUSH-O-METERS Electronics No electronic fixtures, faucets, or flush-o-meters. Under special circumstances, electronic fixtures may be approved on a case-by-case basis. On installations where electronic fixtures are approved, shut-off valves and strainers are mandatory. Hardwire only. No battery operated fixtures will be accepted. As an option to electronics, consider the use of the Chicago 802-VE2805-665CP. This is a pushbutton automatic shut-off faucet. It can also be ordered with quarter turn springloaded automatic shut-off stems. Flush-o-Meters Sloan Royal mechanical type flush-o-meters only. No Delaney or Zurn. No electronics. No air operated flush-o-meters or valves. Faucets and Shower Valves Chicago only. No Acorn, Delta, Powers, or Symmons FAUCET SCHEDULE Application Manufacturer Model Description Lavatory Chicago 802-VCP 2-hole, 4 center-set Lavatory Chicago 802-VE2805-665CP 2-hole, 4 center-set, metered shut off, low flow Kitchen Sink Chicago 1100-GN2AE3-317CP 2-hole, 8 center-set or 895-317CP Kitchen Pre-rinse Chicago 919-LCP Single hole, deck mount Kitchen Pre-rinse Chicago 923-HCLCP wall mount, integral checks Kitchen Pot Filler Chicago 512-GCCP vacuum breaker Kitchen Handwashing Chicago 802-317CP 2-hole, 4 center-set, paddle handles Pantry Chicago 350-CP single hole, cold only Science Lab Sinks Chicago 930-369 CP single hole Science Lab Sinks Chicago 928-369 CP single hole, cold only Science Lab Gas Chicago 909-GASCP ball valve Valve Classroom Sinks Chicago 1100-CP or 1100- GN2AE3VPAXKCP 2-hole, 8 center-set, swing or gooseneck spout Classroom Sinks Chicago 50-CP Single hole, gooseneck spt Classroom Sinks Chicago 748-665CP bubbler drinking fountain Restroom Hose Bib Chicago 952-CP loose key handle Service Sinks Chicago 445-897SRCXKCP wall mount, vacuum breaker, integral checks Shower Valve Chicago 1762-ISVOCCP integral service stops BSD Division 22: Plumbing Design Standards Revised: 12/10/2009 Page 9 of 11

B. VITREOUS CHINA Lavatories Use wall hung, cast iron wall bracket, 4 center-set. Assure proper backing is provided in the wall to support sink. Stamped steel wall brackets are not acceptable. No concealed arms on sinks. No single hole sinks. Standard ADA compliant lavatory Kohler 2032 porcelain sink mounted with cast iron wall bracket. Classroom Sinks Stainless Steel, Elkay #DRKR2517 Water Closets and Urinals Kohler or American Standard VI. DOMESTIC HOT WATER SYSTEM Provide at least two independent hot water systems at all schools. One system is for general use delivering water at 120 F. The second is a dedicated system for kitchen use delivering water at 140 F. A booster will be required to provide 180 F water to dishwasher final rinse. Do not use single tank system with mixing valves to provide dual temperature system. Preferred: Commercial, 199,000 Btu, high efficiency (condensing 92%+) natural gas water heaters, at least one water heater per domestic hot water system. Electric water heaters should not exceed 4.5 kw. Dual element water heaters with two non-simultaneous 4.5 kw elements are acceptable. Electric water heaters may be used in distributed point-of-use systems where natural gas piping is not readily available. Electric, tankless, instantaneous water heaters (e.g., Insta-Hot) will not be allowed. Use six gallon local water heater to serve remote restrooms and other small applications. Use multiple point-of-use mixing valves at the sink or fixture rather than one large valve. Beaverton School District has found central station mixing valves to be unreliable. Point-of-use mixing valves allow greater flexibility in delivery temperatures and minimize disruption of service in surrounding areas should a malfunction occur. VII. KITCHEN Install all equipment per code and per manufacturer s installation instructions. Design for ease of operation and maintenance. Design, service, and outlets per manufacturer s recommendations. Shut-offs shall be protected from accidental damage or shut-off, but be readily accessible from the front side without requiring movement of any equipment. After exiting wall cavity, run piping exposed, tight to wall behind equipment. Stub out 3-0 to shut-off, then transition to flexible hose. All equipment drops on gas lines shall be provided with a pressure tap (test tee). The test tee shall be located after the shut-off and prior to transitioning to flex. Pressure at equipment shall meet manufacturer s requirements. Pressure drop calculations and appliance installation details shall account for pressure drop through flex and connectors. Design documents shall include maximum equivalent pipe length. BSD Division 22: Plumbing Design Standards Revised: 12/10/2009 Page 10 of 11

A. KITCHEN SPRAYERS AND HOSES T & S only B. GARBAGE DISPOSALS Kitchen: Use Red Goat only. Staff room and other applications: 1/2 HP minimum ISE Badger 5, or equal C. HANDWASHING SINKS Equip with 4 paddle handles. D. FOOD PREPARATION SINKS Indirect drains with air-gap as required by code E. FLOOR SINKS Cover portion of floor sinks exposed to foot traffic with grate. Design and locate floor sinks to minimize potential trip hazards but still allow access for maintenance. F. STEAM OVENS AND STEAM KETTLES Provide quick disconnect hoses for ease of maintenance. G. DISHWASHERS Design and plumb for high temperature machines. Along with ease of operation and maintenance, minimizing water use is a prime consideration when selecting and evaluating new dishwashing equipment. H. DISHWASHER BOOSTER HEATERS To minimize electric demand charges, gas-fired booster heaters are preferred. Gasfired boosters must have independent venting and adequate provision for combustion air to prevent odors in the building. Booster must be sized to provide 180 F water to dishwasher final rinse. Booster sizing must take into account all other hot water use at the site. VIII. MISCELLANEOUS A. DRINKING FOUNTAINS One chilled unit per school, ADA compliant (Elkay EZSTL8LC or equal). Others (nonchilled) use standard wall-mounted drinking fountain. Outside drinking fountains are discouraged. Elkay and Sunroc are the preferred manufacturers for both interior and exterior drinking fountains. Install Aqua Pure AP101T water filter on all chilled units and for any other units requiring filtration. B. EYE WASH Eye wash required in all science labs and auto shops. HAWS #H8904 Deck-mount or equal for new construction. HAWS #7610 tower-mount or equal for retro-fits. C. CAN WASH Provide frost-proof valves for all exposed assemblies. Jay R. Smith 3370/3371 Sani-ceptor Can Washing Floor Drain with 3380 valve box or equal. BSD Division 22: Plumbing Design Standards Revised: 12/10/2009 Page 11 of 11