BVERTTURB ITT. Goulds Pumps. Vertical Turbine Pumps. Engineered for life

Similar documents
M-Series Vertical Turbine Pumps. BULLETIN 3A.1 June 2003

Goulds V-Series Vertical Turbine Pumps. Goulds Pumps

Vertical Turbine Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y VTP. Vertical Turbine Pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

Full-line Product Overview

Bulletin B-710A ITT. Bell & Gossett Lineshaft and Submersible Turbine Pumps. Engineered for life

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

470 Series Stamped Stainless Steel Pumps

380 Series Multi-Stage Centrifugal Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

Goulds Trash Hog. Self-Priming Solids Handling Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

Unequaled I Unrivaled I Performance

Industrial. Solutions brands you trust. Product Overview

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Goulds HSU, HSUL & JCU. Submersible Pumps

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

VTP Vertical Turbine, Wet-Pit Pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. ASME/ANSI B73.1 Chemical Process Pump

Selection V 1 INTRODUCTION PAGE V-2 V 2 SUMP/WELL PUMP SELECTION GUIDE PAGE V-3 V 3 CAN PUMP SELECTION GUIDE PAGE V-4

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

380 Series Multi-Stage Centrifugal Pumps

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Goulds 3600 Between-Bearing, Axially-Split, Multi-Stage Pumps. Goulds Pumps

Horizontal Split Case Pumps Type U

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

Dean Pump High Temperature Chemical Process Inline Pumps

FAIRBANKS NIJHUIS SOLIDS HANDLING PUMPS.

MODEL 664A MODEL 662A MODEL 663A MODEL 661A AURORA. 660 Series SINGLE STAGE SOLIDS HANDLING VORTEX PUMPS

Goulds 3600 Between-Bearing, Axially-Split, Multistage Pumps

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

Goulds Large Capacity, Single Stage, Double Suction Pump

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Vertical Heavy Duty Pumps

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

KEENER GRINDER PUMPS

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

Goulds Trash Hog. Self-Priming Solids Handling Pump

VPC Vertical Turbine, Double Case Pump

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y LS BARGE PUMP. Vertical high-flow pump

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SECTION STEAM CONDENSATE PUMPS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

6-30 Vertical Deep Well. Close Coupled Vertical Turbine Submersible Turbine. Pump Type. Application. Description. Materials

TYPE LF/LC/LCV END SUCTION PUMPS

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

EBARA. Submersible Non-clog Pump Model DLFU Model DVFU Model DDLFU

Family Curve. Submersible Grinder Pumps 1¼" and 2" Discharge. Effluent/Grinder Pumps.

Centrifugal Pumps acc. to EN / ISO 2858 with Shaft Sealing Type NCL

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

Experience In Motion. WXH and WXM Utility-Grade Multistage Ring Section Pumps

Centrifugal Pumps acc. to DIN EN ISO 2858 with Shaft Sealing Type NCL

Pumps SELECTION OF A PUMP

HOMA Pump, Ansonia Connecticut

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

References are in agreement with UMRL dated April 2018 **************************************************************************

TECHNICAL. Series 18. Pump Packages

ETP Series - Self Priming Pumps

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y SMF. Vertical Submersible Pump

FEATURES. Other Fed-Flush Arrangements

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

SELF-PRIMING PUMPS CORNELL PUMP COMPANY STX & STL SERIES INDUSTRY LEADING EFFICIENCY WITH CYCLOSEAL SYSTEM EFFICIENT BY DESIGN FIVE-YEAR WARRANTY

swp Self-priming pump for solids handling applications

FLANGE-MOUNT CENTRIFUGAL PUMPS

CombiBloc Close-coupled centrifugal pumps

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

CORNELL PUMP COMPANY REFRIGERATION EFFICIENT BY DESIGN

Corporate Capabilities

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

Vertical Ring-section Pump WKTB. Type Series Booklet

Domestic Pump Condensate Transfer Equipment

- Sewage and Sludge Pumps

Locations Include: Food & Beverage. Chemical. Waste Water Treatment. Pulp & Paper. Energy, Oil & Gas

MANURE PUMPS EFFICIENT BY DESIGN

SERIES ES BASE MOUNTED TURBINE PUMPS

CR A-F-A-E-HQQE 3x400/ HZ

MARLOW PUMPS RECIRCULATION

Pumps Mixers Aeration Controls Services SCANPUMP SPLIT CASING PUMP Z22.

FM 517 San Leon, TX Toll Free: Office: (281) Fax: (281)

Series SR Compact Centrifugal Mag-Drive Pumps. WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

Transcription:

ITT BVERTTURB Goulds Pumps Vertical Turbine Pumps Engineered for life

Short Set Vertical Turbine Pumps Capacities to 20,000 GPM (4545 m 3 /hr) Heads to 1,500 feet (457 m) Bowl sizes from 5 to 30 Design Features Product lube or enclosed lineshaft design. Cast or fabricated discharge head and flanged or threaded column assembly. 416 SS shafting. Other alloys available. Standard cast iron bronze fitted construction. Ductile iron, Ni Al brz, 316 SS or other alloys available. Taperlock or keyed impeller design. Wear rings optional. Packing or mechanical seal design. Built-in alignment and simple piping for less costly installation and ease of maintenance/ reduce downtime. Services Raw Water Intake Pumping Station Cooling Water Commercial/Industrial Municipal Mining 2

Cross Sectional Product Lube VSS Motor Capscrew Motor/Support Motor Support Coupling Guard Stud/Nut Capscrew Support/Head Gasket Bearing By-Pass Line Assembly (Tube & Fittings) Motor Key (Supplied By Motor Vendor) Hub - Motor Ring - Retaining Soc. HD. Capscrew Plate - Adjusting Hex Nut Hub - Pump Pump Key Capscrew Gland/Split Packing Stuffing Box Head Headshaft Mounting Holes By-Pass Return To Sump Capscrew - Col/Head Column - Top Capscrew - Col/Col Hex Nut Column - Intermediate Lineshaft Bearing - Lineshaft Column - Bottom Coupling - Lineshaft Pumpshaft Soc. HD. Capscrew Thrust Ring Key - Impeller Impeller Wear Ring - Bowl Wear Ring - Imp. Sand Collar Bearing - Suction Pipe Plug Capscrew - Col/Bowl Bearing - Bowl Bowl - Top Capscrew - Bowl/Bowl Bowl - INTMD. Capscrew - Bowl/Bell Capscrew - Strainer Strainer (Basket Type) Suction Bell 3

LINESHAFT Cross Sectional Enclosed Lineshaft VSS Motor Motor Key (Supplied By Motor Vendor) Capscrew (Motor/Support) Motor Support Coupling Guard Capscrew Support/Head Tension Plate Oil Lube Water Flush Mounting Holes Hub - Motor Ring - Retaining Soc. HD. Capscrew Plate - Adjusting Hex Nut Hub - Pump Pump Key Pipe Plug Head Tube Nipple Capscrew Col./HD. Headshaft Column - Top Tube - Encl. Bearing - Tube Column - INTMD Capscrew - Col./Col. Hex Nut Lineshaft Column - Bottom Coupling - Lineshaft Adapter - Bearing Capscrew - Col./Bowl Bowl - Disch. Bowl Pumpshaft Soc. HD. Capscrew Thrust Ring Key - Impeller Impeller Wear Ring - Bowl Wear Ring - Imp. Sand Collar Bearing - Suction Pipe Plug Capscrew - Bwl./Disch. Bwl. Bearing - Throttle Bowl - Top Capscrew - Bowl/Bowl Bowl - INTMD Capscrew - Bowl/Bell Capscrew - Strainer Strainer (Basket Type) Suction Bell 4

Pump Bowl Assembly The bowl assembly is the heart of the vertical turbine pump. The impeller and diffuser type casing are designed to deliver the head and capacity that your system requires in the most efficient way possible. The fact that the vertical turbine pump can be multistaged to allow maximum flexibility both in the initial pump selection and in the event that future system modification requires a change in the pump rating. Submerged impellers allow pump to be started without priming. Standard Design Features 1. SUCTION BELL Allow smooth entry of liquid into impeller eye, minimizes vortex formation. 2. SUCTION BELL BEARING Provided for shaft stability. 3. SAND COLLAR Prevents solids from entering suction bearing. 4. IMPELLER Semi-open or enclosed for appropriate service conditions. 5. TAPER LOCK Carbon or alloy steel for fastening impellers on 17 and smaller sizes. 6. KEYED Impeller fastened onto shaft by key and split ring. 7. PUMP SHAFT Heavy duty 416SS standard, available in 316, 17-4 PH, Monel and other alloys for high strength and corrosion resistance. 8. INTERMEDIATE BOWL Available in variety of cast materials. Glass lined cast iron standard 6 through 15 sizes. 9. STAGES Flanged and bolted together for ease of maintenance. Registered fits assure positive alignment. 10. SLEEVE TYPE BEARING Provided at each stage to assure stable operation away from critical speed. In addition to standard features and options shown here, other features are available. A. Hydraulic balancing of impellers to reduce axial downthrust and achieve longer thrust bearing life. B. Independent flushing of bowl bearings and wear rings for abrasive services. C. Hard facing of shaft journals and bearings to protect against abrasion and increase interval between maintenance periods. D. Interior coating on bowls for improved efficiency. E. Dynamic balancing of impellers. F. Strainer to prevent foreign objects from entering the pump. 5

Type U Discharge Located Underground Type L (Can) Suction Inlet Located in the Can Type F Head Type T Suction Inlet Located in the Head 6

Pump Bowl Assembly Options CHOICE OF SEMI-OPEN OR ENCLOSED IMPELLERS Available in alloy construction for a wide range of corrosive/ abrasive services. KEYED IMPELLERS Keyed impellers are standard on 18 and larger sizes, furnished on all pumps for temperatures above 180º F (82º C). Regardless of size, keyed impellers provide ease of maintenance and positive locking under fluctuating load and temperature conditions. WEAR RINGS Available for enclosed impellers and bowls; permts re-establishing initial running clearances and efficiency at lower cost. Hard facing of wear rings can be furnished when solids are present in pumpage. Coupling Arrangements RIGID FLANGED COUPLING (Type AR) To couple pump to vertical hollow shaft driver. Impeller adjustment is performed on adjusting nut located on top of motor. ADJUSTABLE COUPLING (Type A) For vertical solid shaft driver. Impeller adjustment made by using adjustable plate in the coupling. ADJUSTABLE SPACER COUPLING (Type AS) Same function as type A coupling with addition of spacer. Spacer may be removed for mechanical seal maintenance without disturbing driver. 7

Sealing Flexibility PACKED BOX WITH SLEEVE OPEN LINESHAFT Whenever packing, lubrication leakage can be tolerated and the discharge pressure does not exceed 300 psi, a packed box may be used. Optional headshaft sleeve available to protect shaft. WATER FLUSH ENCLOSED LINESHAFT Water flush tube connection is supplied when pressurized water is introduced into the enclosing tube for bearing protection on abrasive services. OIL LUBRICATED ENCLOSED LINESHAFT Oil lubricated option is recommended when water elevation would cause the upper lineshaft bearings to run without lubrication during startup. Oil is fed through tapped opening and allowed to gravitate down enclosing tube lubricating bearings. 8 SINGLE SEAL Most popular method used for low to medium pressures. Cartridge style for ease of installation and maintenance. OUTSIDE MOUNTED SEALS Provides a method of no-leak sealing for low pressure and water application. TANDEM SEALS Two seals mounted in-line. Chamber between seals can be filled with a buffer liquid and may be fitted with a pressure sensitive annunciating device for safety.

SUBMERSIBLE 1 Applications Goulds Pumps combines the hydraulic engineering of turbine pumps matched to the hi-tech design of electric submersible motors. Features 1 Discharge Pipe Properly sized for optimum water velocities to insure peak hydraulic performance. 2 Discharge Bowl Several discharge sizes available for NPT or flanged pipe. 3 Discharge Bearing Extra long top protected bronze bearing insures positive shaft alignment and stabilization for extended life. 4 Intermediate Bowl Glass lined cast iron standard 6 through 15 size for maximum efficiency and abrasion resistance. 5 Impellers Designed for maximum efficiency with wide range hydraulic coverage. Precision balanced for smooth operation. 6 Upthrust Washer Designed for extra margin of safety against possible momentary upthrust occurring at startup. 7 Intermediate Bowl Bearings Reliable long life bronze or rubber bearing. 8 Taper Lock Accurately machined to insure positive locking of impeller to pump shaft. 9 Pump Shaft 100,000 PSI high tensile stainless steel provides strength and excellent corrosion resistance. Ground and polished for smooth bearing surface. 10 Suction Inlet Contoured for smooth flow entrance. Protected by an oversized stainless steel strainer to prevent entrance of damaging solids. 11 Suction Adapter Ductile iron provides for increased strength and positive motor alignment. Open area permits easy access to pump/motor coupling. 12 Pump/Motor Coupling Large stainless steel coupling accurately machined for perfect alignment, balance and power transmission. Submersible pumps and motors provide an extensive list of options versus other deep well pumping equipment systems. Advanced engineering designs and experience assure units for long term pumping service. Water well applications provide the perfect opportunity to evaluate features and benefits of submersible equipment. 6 10 11 2 3 4 5 7 8 9 12 9

Hermetically Sealed Type A Hermetically Sealed Type motor utilizes windings of standard construction and insulation thickness. The windings are encased and Hermetically Sealed within the external shell casing on the outside and an internal tube or liner inside the bore. The Hermetically Sealed enclosure eliminates the possibility of water leakage into the winding. The liquid medium circulates between the rotor and stator liner providing lubrication and cooling to the bearings. Submersible Options Goulds Pumps can provide several options in pump and motor combinations to meet the exacting conditions of your applications: High temperature wells High horsepower, limited well diameters Motor sensing devices Water level indicators Special materials Special voltage motors Consult Goulds Pumps Turbine Customer Service Dept. for details. Wet Winding Type A Wet Winding Type motor is one in which the motor windings are in direct contact with a liquid medium. The medium is clean, clear water. A pressure balancing system prevents exchange of the motor liquid medium and well water due to thermal expansion and contraction when the motor is operating. The liquid medium fills the inside of the motor and surrounds both the stator windings and the rotor. A completely water proof insulation is used on the magnet wire used for the stator windings. The liquid medium inside the motor air gap and coils acts as a heat transfer device by circulating through the windings and transferring heat to the external casing. Dissipation of this heat occurs as the well water flows at a required velocity over the external case. As is the case in all submersible type motors, the internal liquid medium is also used for bearing lubrication. Submersible Accessories: Valves Check Valves Flow Control Gate Valves Ball Valves Electrical Panels Furnas Panels V.F.D. Drivers Pitless Adapters Wire 12 to 0000 Heat Shrinks Splice Kits Tanks Well Heads Submersible Discharge Head Torque Arrestors Gauges Motor Shrouds 10

400 300 13RAH 250 200 3450 RPM 60 Hz 10RAH 11RAH 9BM 13RAL 11CL HEAD PER STAGE (FT.) 150 100 90 80 70 60 6RAH 7RAL 7RAH 8RAL 8RAH 6CL 7WAH 7WAL 9WAH 9WAL 8IH 8IL 7CH 7CL 6CH 6DHH 8RJL 10WAL 8DHL 7TH 7TL 8RJH 9RCH 9RCL 10RJL 9TL 8DHH 9TH 50 5WAH 5CH 40 5WAL 5CL 5TH 30 25 5TL 6DHL 20.2.3.4.6.8 1 1.5 2 3 4 5 6 7 8 9 10 15 20 25 30 40 FLOW (100 U.S. GPM) HEAD PER STAGE (FT.) 250 200 150 100 90 80 70 60 50 40 30 25 20 15 6RAH 1770 RPM 60 Hz 7RAL 7RAH 8RAH 7WAH 7WAL 8RAL 6CH 6CL 10RAH 9WAH 9WAL 8IH 8IL 7CL 7CH 8RJL 7TL 10WAL 13RAH 12WAH 12WAM 11CH 11CM 11WAH 11RAH 11CL 9BM 9RCH 10RJ 8RJH 8DIL 7TH 10RJL 9RCL 8DHH 13CM 13CH 12FRH 12DHH 12RJH 12RJM 12DHL 10LH 10DHH 9TL 9TH 12CHC 20BH 18CH 18BH 18BL 16DHH 18LH 16DM 16BHC 16DHL 15F 16BLC 14F 14RJH 14RJM 14DHL 14RHH 14RHM 14RJL 18HM 18DM 20EH 18DH 16F 16RGH 5WAH 5CH 5WAL 5CL 6DHH 10 9 8 7 0.2 0.3 0.4 0.6 0.8 1 1.5 2 3 4 5 6 7 8 9 10 15 20 25 30 40 50 60 70 80 100 5TL 5TH 6DHL FLOW (100 U.S. GPM) 11

250 200 150 1180 RPM 60 Hz 24CL 24CH 28CH 28CL 30BL 28BH 28BL 30BH HEAD PER STAGE (FT.) 100 90 80 70 60 50 40 30 25 20 15 7WAH 9WAL 9WAH 8IH 8IL 10RAH 13CM 13CH 12CHC 12WAH 11CH 12WAM 11WAH 11CL 11RAH 9BM 9RCH 10RJ 10WAL 10RJL 9RCL 13RAH 11CM 9TH 14RJL 12RJH 12RJM 10DHH 16BLC 24DM 24EH 20CH 24EL 20CL 20BH 18CH 18DM 18BH 16DM 18LH 15F 14F 18BL 16BHC 14RHH 14RJH 14RJM 14DHL 12FRH 12DHH 12DHL 10LH 16DHH 14RHM 20EH 16F 16RGH 20GL 20GH 28TM 24GH 24FH 18DH 18HM 16DHH 26GH 28GH 7WAL 7CH 8RJL 7CL 8RJH 8DHL 7TH 9TL 10 9 8 7 0.4 0.6 0.8 1 1.5 2 3 4 5 6 7 8 9 10 15 20 25 30 40 50 60 70 80 100 7CH 8DHH 150 200 300 FLOW (100 U.S. GPM) 250 200 150 885 RPM 60 Hz HEAD PER STAGE (FT.) 100 90 80 70 60 50 40 30 25 20 15 10 9 8 7 0.4 0.6 0.8 1 1.5 2 3 4 5 6 7 8 9 10 15 20 25 30 40 50 60 70 80 100 9WAL 10RAH 9WAH 8IH 13CH 12CHC 12WAH 11CH 12WAM 11WAH 11CL 11RAH 9BM 9RCH 10RJ 10WAL 9RCL 13CM 13RAH 11CM 9TH 14RJL 12RJH 12RJM 10DHH 16BLC 24CH 24DM 24CL 24EH 20CH 24EL 20CL 20BH 18CH 18DM 18BH 16DM 18LH 15F 14F 18BL 16BHC 14RHH 14RJH 14RJM 14DHL 12FRH 12DHH 12DHL 16DHL 14RHM FLOW (100 U.S. GPM) 20EH 16F 16RGH 20GL 28CH 28CL 30BL 28BH 28BL 20GH 28TM 24GH 24FH 18DH 18HM 16DHH 26GH 30BH 28GH 150 200 300 12

100 90 80 70 60 50 2850 RPM 50 Hz 10WAL 11RAH 12WAH 11WAH 13RAH HEAD PER STAGE (m) 40 30 25 20 15 7RAH 8RAL 8RAH 9WAL 8IL 7WAH 7WAL 7CL 9WAH 8IH 7CH 8RJL 11CL 9BM 9RCH 9TH 10WAL 9RCL 9TL 10RJL 8DHH 8RJH 11CH 12CH 8RAH 7RAL 6CL 6CH 7TL 8DHL 7TH 10 9 8 7 5WAL 5WAH 5CL 5CH 5TL 5TH 6DHH 6DHL.4.6.8 1.0 1.5 2.0 3 4 5 6 7 8 9 10 15 20 25 30 40 50 FLOW (10 Cu. M/Hr) 60 70 HEAD PER STAGE (m) 100 90 80 70 60 50 40 30 25 20 15 10 9 8 7 6 5.6 7RAL.8 7RAH 8RAL 1 1470 RPM 50 Hz 8RAH 1.5 7WAH 7WAL 6CH 2 9WAL 8IL 7CL 10RAH 9WAH 8IH 7CH 8RJL 10WAH 12RAH 13CL 13CHC 13WAH 11CH 13WAM 11WAH 11RAH 11CL 11CM 12RJM 9BN 9RCH 10RJ 10DHH 10RJL 8RJH 8DHL 7TH 9RCL 8DHH 9TL 9TH 14RJM 13CH 12RJH 12DHL 10LH 16BLC 14RJL 20CH 20CL 20BH 18CH 18DM 18BH 18BL 16DM 16DHH 16BHC 16GH 3 4 5 6 7 8 9 10 15 20 25 30 40 50 60 80 100 150 200 300 FLOW (10 Cu. M/Hr) 14RJH 14DHL 12DHH 12FRH 14RHH 16DHL 14F 14RHM 15F 20EH 18LH 16GL 24EH 24EL 20GH 20GL 18HM 18DH 13

NOTES 14

NOTES 15

UK Lubbock, TX Canada USA Belgium France Portugal Netherlands Germany Italy China Mexico Venezuela Philippines Singapore Australia The trusted Goulds Pumps name... Almost 160 years ago in Seneca Falls NY, Seabury S. Gould cast the world s first all metal pump. This was a major step in building a business that would grow into one of the largest pump manufacturers in the world, and a creating a pump brand that is trusted and revered around the globe. Today, the Goulds Pumps brand is an integral part of ITT s Residential & Commercial Water group (ITT R&CW). The trusted Goulds Pumps name can be found on a full range of pump products, including submersible and lineshaft turbine, 4 submersible, jet, sump, effluent, sewage and centrifugal, as well as double suction, multi-stage, slurry and process pumps. ITT R&CW is a global leader in the industrial and water technologies markets, producing the world s leading line of residential water well pumps, circulating pumps, wastewater pumps, controls and accessories. Goulds Pumps...Leading The Way Since 1848. Turbine Distribution Centers: Phone Fax LUBBOCK, TX P.O. Box 5487, Lubbock, TX 79408 1-806-763-7867 1-806-743-5730 MEMPHIS, TN 5815 Shelby Drive, Memphis, TN 38141 1-901-375-9965 1-800-453-4745 ORLANDO, FL 1150 Emma Oaks Trail, Suite 150, Lake Mary, FL 32746 1-407-829-7724 1-407-829-7725 FRESNO, CA 3878 S. Willow Ave., #104, Fresno, CA 93725 1-559-265-4730 1-800-453-7523 1-559-265-4740 Specifications & Special Projects: LUBBOCK CUSTOMER SERVICE CENTER 1-806-763-7867 1-800-453-4749 ITT 2881 East Bayard Street Seneca Falls, NY 13148 Phone: (315) 568-7123 Fax: (315) 568-7973 www.goulds.com Engineered for life Copyright 2010 ITT Corporation BVERTTURB January, 2010 Printed in U.S.A. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.