MLTXD16 Temperature Datalogger with Internal and External Sensor. Accuracy & Resolution ±0.3 C avg res. 0.5 C Storage Temperature -40/85 C

Similar documents
EL-USB-1-LCD Temperature Data Logger with LCD

EL-USB-1-LCD Temperature Data Logger with LCD

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

EasyLog Data Logger Series

EL-OEM-3 OEM Packaged Voltage Data Logger

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Specifications Minimum Typical Maximum Unit

EasyLog Data Logger Series

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

EL-USB-TC Thermocouple Data Logger with USB Interface

ELMTEC. Kattreppeln Königslutter / /

DataSheet. Thermocouple Logger


EL-OEM-3 OEM Packaged Voltage Data Logger

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

DataSheet. Thermocouple Logger

Sirius Technologies, Inc.

portable gas analyser

User Manual. Humidity-Temperature Chart Recorder. Model RH520

USER MANUAL USB Multi-Function Datalogger Model RHT35

THERMOMETERS Dataloggers/Refrigerator

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

Introduction. OM-THA2

THX-DL Data Logger USER & INSTALLATION MANUAL V

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2

MR SERIES CARD LOGGERS

Constant climate chambers

iminiplus PDF User Guide Version 2.0

Temperature/Humidity Monitor. User s Manual

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

portable gas analyser

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

FLOW CONTROLLER TYPE S/601

Remote. control unit. accessories. Leak detector SmartTest. Remote control unit for SmartTest. Remote. Vacuum analysis and measurement

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Constant climate chambers

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

Laboratory Refrigerator/Deep Freezer TC 802

Cold chain monitoring technologies. Facility monitoring

OPERATION MANUAL TEMPERATURE. HUMIDITY MONITOR / ON-LINE LOGGER. Monitor. On-line Logger AMT208 AMT207

HRX Technical Manual. Version 1.2

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Microtherm Heat Stress WBGT

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

ECOLOG Datalogger Series

data logger DL200H DL200D DL200L

Multi-Lab REFRIGERATORS Frigidere medicale

Air & Water Heat Pump R832

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Software Version 2.01 LEVEL MONITOR MODEL 220

HRX3000. Technical Manual

Constant climate chamber with humidity

Data Logging Solutions

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

Constant climate chambers

WeatherLink for Alarm Output Addendum

Chromatographic Air circulated Refrigerator, two-door TC 603

Blood bank refrigerators and freezers. BBR & Mini - Platinum & Iridium - Plasmafrost Series

Ethernet General Purpose

D3 Wireless temperature alarm & monitoring system family. tek-troniks

ECOLOG-NET LA8 and WA8 (wireless), 8 x 4..20mA signals

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Constant climate chambers

Registered address: 7 Drakes Drive, Crendon Business Park Long Crendon, HP18 9FE

VM-3000 Mercury Vapor Monitor

The EN54 Part 2 & 4 Fire System

DGC-500 DIGITAL GENSET CONTROLLER

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

Long Term Storage Cabinet

XSD Dry Cabinet

Batt-Safe Battery String Monitoring System

APPLICATION DATA SHEET

LogTag TICT - is0 Tag

2014, TempSen Electronics Company

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

AS950 REFRIGERATED SAMPLERS

Chromatographic Air circulated Refrigerator, two-door TC 603

AS950 PORTABLE SAMPLERS

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

THX-DL Data Logger USER & INSTALLATION MANUAL V Refrigeration

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C


ECOLOG Data logger series we prove it.

DGC-1000 DIGITAL GENSET CONTROLLER

R.I.S. (Remote Intelligent Sensor)

APPLICATION DATA SHEET

AirTest Technologies Inc.

Access Control (card access)

Omniguard 4: Features

Transcription:

Dataloggers Monolog 2 offers a comprehensive range of portable self-powered datalogging devices for numerous sensor types that utilise the latest electronics and software. A range of common software and interface platforms will cater for the variety of applications requiring critical condition measurementt MLTD16 Temperature Datalogger with Internal Sensor Battery Type & Life IP rating -40 C to +70 C 16,000 Readings ±0.3 C Avg. Res. 0.5 C User Replaceable Lithium Battery, 1-2 years battery life depending on use IP67 70g Ø75mm (excluding lug), Ht 18mm 12 month (excluding batteries) Windows MLSWARE Windows software MLTXD16 Temperature Datalogger with Internal and External Sensor -40 C to +70 C ±0.3 C avg res. 0.5 C Temperature response time Internal sensor T90 of 12min s/s tipped external sensor T90 of 4 min. in moving air Real time clock, accuracy better than 40 secs. Per month at ambient 1 to 2 years (dependant of PC communication) Data recover y MSWARE, console STD, console PRO operating Windows 95 onwards MLSWARE Monolog 2 software disc for windows

Dataloggers MLTXXD16 - Temperature Datalogger with 2 External Temperature Sensors -40 C to +70 C ±0.3 C avg. res. 0.5 C LED's Green LED = Active/ Red LED = Alarm (plastic case only) Temperature response s/s tipped external sensors T90 of 4 min. in moving air time Real time clock, accuracy better than 40 secs. Per month at ambient 1 to 2 years (dependant of PC communication) Windows for 3.1, 95, 98, NT onwards Windows MLSWARE Windows software MLTHB16 - Datalogger Temperature and Humidity Sensors Temperature Measuring Range -20 C to +60 C Humidity Measuring Range 0 to 100% Accuracy and Resolution Temperature ±0.3 C avg. res 0.3 C Humidity ±0.3% at ambient, res 0.5% d an response time of T90 in 10 seconds moving air 100 grams Elongated Temperature probe T90 of less than 1 minute for external sensor in moving air response time LED s Humidity measuring range Green LED = Active/ Red LED = Alarm 0 to 100%, accuracy ±3% at ambient, resolution 0.5% and response time in 10 seconds in moving air Real time clock, accuracy better than 40 secs. per month at ambien t Tractability Temperature/Humidity Calibration can be provided to ISO 9002 Sampling Frequency 1 to 255 minutes 1 to 2 years (dependant on frequency of PC communication) Dia. (excluding lug) 75mm, Ht. 50mm Via ChartReader, or interface and IBM compatible PC Windows 3.1, 95, 98, NT onwards MLSWARE Monolog 2 software disc for windows

Monolog 2 offers a comprehensive range of portable self-powered datalogging devices for numerous sensor types that utilise the latest electronics and software. A range of common software and interface platforms will cater for the variety of applications requiring critical condition measurementt ML-IE-DN-16/L - Temperature Datalogger with Internal and External Sensor Internal - 40 C to +70 C External - 100 C to +40 C Internal ±0.3 C avg res. 0.5 C External ±0.3 C avg res. 0.5 C - 40 to 85 C LED's Green LED = Active/ Red LED = Alarm (plastic case only) Temperature response time Internal sensor T90 of 12min s/s tipped external sensor T90 of 4 min. in moving air Real time clock, accuracy better than 40 secs. Per month at am bient Multiple time zones supported 1 to 2 years (dependant of PC communication ) MLSWARE, console STD, console pro operating Windows 95 onwards Programm ed time and date or magnet swipe LCD Optional ML - IE - DN - 16L Windows MLSWARE Windows software ML-OE-KJ-16L - Temperature Datalogger with External Thermocouple input Connection Type Battery Type & Life IP rating Data Recovery Recorder Start - up LCD Optional 0 C to +500 C 2 pin miniature 16,000 readings ±4 C, Res. 2 C over range User Replaceable Lithium Battery, 1-2 years bat tery life depending on use Download via PC interface and IBM compatible PC or print out through Chart Reader MLSWARE, console STD, console pro operating Windows 95 onwards Programmed time & date o r magnet swipe Real Time clock, accuracy better than 40 seconds per month at ambient. Multiple time zones supported - 40 to +80 C 70g Ø 75 mm, Ht 18mm 12 months (excluding batteries) Inclusive MLSWARE Monolog 2 software disc for windows

Monolog 2 offers a comprehensive range of portable self-powered datalogging devices for numerous sensor types that utilise the latest electronics and software. A range of common software and interface platforms will cater for the variety of applications requiring critical condition measurementt ML-IE-DC-16/ EJ-IE-DC-16L - Temperature Datalogger with Internal and External Sensor Internal -40 C to +70 C External -20 C to +100 C Internal ±0.3 C avg res. 0.5 C External ±0.3 C avg res. 0.5 C LED's Green LED = Active/ Red LED = Alarm (plastic case only) Temperature response time Internal sensor T90 of 12min s/s tipped external sensor T90 of 4 min. in moving air Real time clock, accuracy better than 40 secs. Per month at ambient 1 to 2 years (dependant of PC communication) MSWARE, console STD, console PRO operating Windows 95 onwards LCD Optional EJ-IE-DC-16L Windows MLSWARE Windows software MLTV8 - High Temperature Datalogger with Internal Temperature Sensor Temperature Measuring Range Accuracy and Resolution Temperature response time Sampling frequency Time & Date 0to +125 C ±0.5 C avg. res 0.5 C -40 to +85 C T90 of 12 min. in moving air 1 to 2 years depending on frequency of PC communication Polysulfone IP68 Real time clock, accuracy better than 40 seconds per month at ambient. Multiple time zones supported. Download via PC interface and IBM compatible PC pr printout through Chartreader Windows 95 onwards MLSWARE Monolog 2 software disc for windows

MLTACXZY2 - High Temperature Autoclave Logger The Autoclave logger is a special product that can withstand high temperature and pressure environments to +150 C/5 Bar for 30 minutes, 150 C for 60 minutes in dry heat and indefinite operation at +125 C. Primary intended use is the qualification of Autoclaves used for sterilisation but is also suitable for measuring any high temperature applications not exceeding the specifications below. The product is supplied with a stub probe that registers the environment temperature from +25 C to +150 C, and an internal temperature sensor for monitoring of logger internal temperature conditions and prohibiting reprogramming of logger until internal temperature has returned to 40 C. Battery is user replaceable.. Endurance Ratings Sensors Elongated Temperature probe sensor time Time & Date Battery Type & Life IP rating -25 C to +150 C Rated autoclave @ 150 Cm 5bar:30 minutes Typical oven (dry heat) @ 150 C:60 minutes Oven (dry heat) @ 125 C@ indefinite (depending on battery life) provided temperature never exceeds 125 C 2000 Readings for temperatures > 22 o C±0.5 C Avg. Res. 0.5 C External sensor used for sampling environment under test Internal sensor measuring range of 1/150 C used for diagnostic purposes only 0/125 C T90 of less than 4 minutes for temperature probe in moving air Real time clock, accuracy better than 40secs per month at ambient User Replaceable high temperature Lithium Battery, 1 year battery life depending on use Interface and IBM compatible PC IP68 tested to 5 bar 316 Stainless steel & PEEK high temperature resin 345g Ø65mm, Ht 43mm, probe height 50mm and probe Ø4.5mm MSWARE, console STD, console PRO operating Windows 3.1, 95,98 and NT onwards Programmed time & date or magnet swipe 12 months (excluding batteries) MLSWARE Monolog 2 disk for windows MLSWARE Monolog 2 software disc for windows

Monolog 2 Alarm Link An alarm link interface that allows the alarm status in the logger to control an external device (i.e siren). Dia. 80mm, Ht 35mm 50 grams -40 to +85 C Earliest firmware revisions of Junior required for support of Alarm link The earliest firmware versions which support the Alarm Link are 1.1c (for 1.XX loggers), 2.3c (for 2.XX loggers) and 3.2c (for 3.XX loggers). Also, your logger must have the ability to indicate an alarm status, either through LED s, an LCD or through an audible alarm, which is denoted by Alarm Compatibility Symbol Power Requirements 9-24 Volts DC, 100mA, External Source Alarm Output NC or NO, 0.5A @ 24VDC. maximum switched power 30W. 12 Months Chart Reader The Chartreader allows download and printout of logged readings without the use of a computer. Printout can be either in a list of out of specification readings or a graph. Muliple sets of downloaded logged readings can be stored in the ChartReader s non-volatile memory for later transfer to a PC 1MB non-volatile memory, storage sufficient for download of 300 typical logger data sets. Printer Mechanism Impact printer (accepts duplication printing paper) Printer Speed 3.5 lines per second (equivalent to1333 logs per minute) IP50 Data Recovery Download via PC interface and IBM compatible PC or printout Length 225mm, width 120mm, height 100mm 0/80 C (32/176 F) 1.125 kilograms Rechargeable NiCad battery Battery Life Before Typically one hour continuous printing Recharge Battery Recharge Time Typically 90% in one hour Recharge Adaptor Rating 12 volts @ 1 Amp or vehicle cigarette lighter (Adaptor not supplied) Configuration Console for Windows 98 or later, available free on www.digitron.co.uk Operating Temperature 0/50 C (32/122 F) 12 months, excluding batteries Interface Holder The Alarm Link Interface Holder is designed to hold the Alarm Link Interface together with a Monolog 2 Logger secure in position. Its four screw holes make it easy to fix wherever you need it to be. 62gms 100 x 96 x 43mm