SUPREMATouch. Modular Fire & Gas Detection System

Similar documents
SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch Modular Fire & Gas Detection System

Touchpoint Pro Flexible Gas Control System

IGD.CO.UK

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

MSA Fixed Gas & Flame Detection for the Automotive Industry

APPLICATION DATA SHEET

Industrial Grade Gas Detection Detecting The Difference

APPLICATION DATA SHEET

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

On the job around the clock 24/7: Fire detection systems

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Advanced FireAlarm Panel 1-4Loop

System 57. An advanced World of intelligent gas detection system management

Fire and Gas Monitoring Panel ST7-HV

Dräger Polytron 7000 Fixed gas detector

Dräger REGARD 3900 Series Control System

Products and performance

SAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.

The Next Generation Machine Protection System

YOUR PARTNER IN FIRE & GAS DETECTION

Dependable Solutions for Gas Detection

For Complete Fire and Gas Solutions

MODEL 9010/9020 LCD CONTROL UNIT

P R O D U C T D ATA S H E E T

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Touchpoint Plus. A whole new control experience

System 57. An advanced world of intelligent gas detection system management

Zareba System Overview

P R O D U C T D ATA S H E E T

Model D12-IR. Digital Gas Transmitter...

P R O D U C T D ATA S H E E T

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

GasGard 100 Control System

Dräger Polytron 8000 Stationary gas detector (EC)

P R O D U C T D ATA S H E E T

Bionics Instrument. Alarm Handling. Gas Alarm Systems

RAYCHEM NGC-30 COMPONENTS

Gas Controller Module GC-06

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Vigilant MX4428 Fire Alarm System

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Fire control panel detect 3004 plus and accessories

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Intelligent addressable fire alarm control panel

APPLICATION DATA SHEET

Gas Detection. Touchpoint Plus. A whole new control experience

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

Industrial Grade Gas Detection

P R O D U C T D ATA S H E E T

Danfoss gas detection Controller unit

RS485 MODBUS Module 8AI

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Process Alarm Solutions

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

P R O D U C T D ATA S H E E T

Dräger Polytron 8100 EC Detection of toxic gases and vapors

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Fire Detection Systems Product Catalogue (Version )

GMA200-MW4. User Manual. Gas detection controller for wall mounting

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

Danfoss gas detection unit Type GD Heavy Duty

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

IQ8Control C Fire Alarm Panel

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

The EN54 Part 2 & 4 Fire System

CATALOGUE Controls/Networks STRACK LIFT AUTOMATION. MULTiBUS -Coupler

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Touchpoint Plus. A whole new control experience

Fixed Gas & Flame Detection International Product Range Overview

Honeywell SLATE ICM Platform

Instrumentation Products and Applications

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Process & TeMPerATUre UniversAl input DigiTAl MeTers

DTM Distributed Transmitter-Monitor

Operating Instructions

Reliably Advanced Extinguishing Control

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger PointGard 2100 Detection of toxic gases and vapours

Intelligent Single Loop Fire Alarm Control Panel

Detection, Protection, Innovation

System 9000TS Sequence of Events Recorder

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Toxic Gas Detection. Model F12. Toxic Gas Detection

Transcription:

SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@

Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in a wide range of industries from simple applications to large systems including complete fire & gas systems. SUPREMATouch modular design meets the requirements of this diverse range of industries and applications and complies with all relevant global safety standards. It builds on the success of the original innovative SUPREMA design and includes a large colour touch screen display, enhanced processing power and addressable fire and detector capability. It can be used with a wide range of detectors including flammable and toxic gas, oxygen, smoke, fire and heat and manual call points. A range of outputs are provided including relay, analogue and digital for communication between racks and which allows inter facing to external systems using Modbus or Profibus. The modular SUPREMATouch design provides a fire & gas detection system that can be configured to meet the requirements of virtually any application including redundant systems with up to Safety Integrity Level SIL 3 rating (IEC 6508). Whatever the application our long experience in fire and gas detection allows us to recommend the best combination of detectors, field devices, components and systems that will ensure reliable and secure protection of your personnel and facilities. Tel: +44 (0)8 9388 Email: info@

Modular Design for Individual Solutions SUPREMATouch is compatible with all MSA fire and gas detectors and can accommodate a variety of third party devices such as 4 0 ma transmitters and heat and smoke sensors. Open-collector driver outputs (4 V, 0.3 A) provide direct control of relays or other circuit elements such as contactors, switches or solenoid valves. With SUPREMATouch digital signal transmission is possible via Modbus and Profibus and there is also the option for analogue outputs. Designed around standard industrial 9 racks, SUPREMATouch provides signal processing for up to 56 inputs and 5 outputs and the ability to distribute the system over up to 8 racks using satellites to minimise installation cost. The modular design allows input and output connections to be mounted on the backplane or DIN rail mounted. System Flexibility Innovative modular assembly Easy checkbox selection to link measurement input with appropriate output Simple alarm configuration by checkbox selection including voting and grouping Variable and customised system layout SUPREMATouch Block Diagram MRO MRO MODULES Field devices MRC MRC MCP Central Processor MDA Digital Acquisition MAT MLE MLE MAI Analogue Input MGO General Output MAT Analogue Terminal MLE Logic Extension MAR MRO Relay Output MRC Relay Control MCP MCP MDA MDA MAI (... 8) MAO MGO MGO MDO Display & Operation CAN Bridge CAN A CAN Bridge CAN B + Non-redundant system Redundant system Gateway Gateway Optional modules MDO AC Power RS3 DC Power Battery USB PC Tel: +44 (0)8 9388 Email: info@ 3

Simple Operation The user friendly touch screen user interface makes installation, configuration, commissioning and operation of the SUPREMATouch extremely simple. No programming skills are necessary. The status signals of up to 56 sensors can be linked and grouped with up to 5 outputs, by selecting a checkbox with a simple touch of the display or a mouse click at a connected PC. Colour LCD touch screen with LED back light Menu driven graphical user interface Detailed diagnostics and event logging No programming required Simple parameter configuration and calibration Comprehensive measurement input information Optional user defined sensor parameters Simple alarm assignment and configuration Digital output inhibit functions 3 level password security SUPREMA Manager MSA software is available for a USB connected PC which is especially useful during commissioning and regular sensor calibration of larger systems. This provides all the functions available at the SUPREMATouch display such as configuration and calibration, offline use and the storing and printing of reports as PDF documents. This provides a user friendly environment for configuration (screen view shown), parameter setting and sensor calibration of large systems to minimise the cost of maintaining SUPREMATouch. Tel: +44 (0)8 9388 Email: info@ 4

Made-to-Measure Safety SUPREMATouch provides a control system that meets the user s safety requirements. The modular system allows I/O (Input/Output) connections to be rail or back plane mounted and be configured as desired and adapted to meet each specific monitoring task. SUPREMATouch is capable of controlling all system functions, including inhibiting I/O, alarm activation, analogue output signals, handling I/O faults, managing voting allocation of status signals and switched outputs, control of annunciation panels and devices such as fans and dampers as well as interfacing to other systems (HVAC, ESD, etc.) through digital bus communications. The SUPREMATouch digital bus technology ensures reliable communication between racks and provides the flexibility of being able to have up to 8 satellite racks per system located at distances up to 5000 m apart. This ensures system wiring is minimized and overall system costs are as low as possible. The SUPREMATouch system also interfaces to external bus systems such as Modbus and Profibus. Features Compact modular design requires fewer cabinets Decentralised configuration Plug-in ribbon cables Future oriented technology Digital bus technology System configuration by checkbox selection Connections for 3 system power supplies Benefits Space saving Use of satellites minimizes wiring Easy installation and system extension Reduces upgrade costs Reliable communication to external bus systems No programming skills required Automatic switchover to backup supply SUPREMATouch is certified to all relevant standards in the field of fire and gas hazard detection: ATEX (EN 5004, EN 507, EN 60079-9-; EXAM) CSA, ccsaus SIL 3 (EN 5040, EN 6508; TÜV) CCCF (GB6808-008) GOST-R Tel: +44 (0)8 9388 Email: info@ 5

Technical Specifications Enclosure System Inputs Outputs Power supply Display Controls and indicators Sensors Approvals Interfaces Standard 9 rack 3U high (up to 8 racks per system) Satellites for decentralised input and outputs up to a distance of 5000 m Optional redundant configuration Event and fault diagnosis logging Up to 56 per system Up to 64 per rack Up to 5 per system Up to 80 per rack Switched open-collector driver (4 V, 300 ma) Relays SPCO or SPST redundant (30 V, 3A) Optional solid state relays for low current applications Software-control of switched outputs/relays creation of groups n out of m alarms alarm multiplication Operating voltage range 8 to 3 VDC Optional rack power supply 85 to 65 VAC, 50 W, 50/60 Hz Power supply connections for internal, external and battery backup (4 VDC) with automatic switch-over Colour LCD touch screen with backlight 5.7 TFT with 30 x 40 resolution Alarm reset and acknowledge keys Front panel LED s for alarms,, 3 and 4, signal fail, inhibit, power and system fail 3 level password or keyswitch for secure access control Catalytic or IR for combustible 4 0 ma transmitters Electrochemical for toxic and oxygen Conventional smoke, heat and fire detectors Addressable smoke, heat and fire detectors via external fire panel ATEX (EN 5004, EN 507, EN 60079-9-; EXAM) CSA, ccsaus SIL 3 (EN 5040, EN 6508; TÜV) CCCF (GB6808-008) GOST-R Optional interfaces to external bus systems (Modbus RTU and TCP, Profibus) x RS-3 and x USB electrically isolated interfaces for data transfer Printer report of system events (standard ASCII, 80 CHR) Detailed ordering information available upon request. Tel: +44 (0)8 9388 Email: info@ 6