Residential Fire Fighting Booster Systems

Similar documents
Residential & Commercial Water Booster Systems Frequency Controlled Water Booster Systems

Fire Pump Systems In Accordance With TS EN A2 Standard

HORIZONTAL SINGLE-LEVEL CENTRIFUGAL PUMPS INSTALLATION GUIDE

Parts Washers, Water Pumps, special applications

PRESSURE ASSEMBLIES WITH ONE PUMP

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

SSA Serie. Features. Model code. Applications. Performance Curves. Operation Conditions. Materials

1 of 68. Thong Fatt Jaya Machinery Hardware Sdn. Bhd. DOUBLE-STAGE LIQUID RING VACUUM PUMP. Air- Operated Double Diaphragm Pump TW Series

MARINE. High efficiency pumps you can rely on

ENGINE DRIVEN PUMPS PRODUCTS

CLIMATE AND WATER MAKERS. Chap. Desalination Purifiers Self contained units Split units. -

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

TECHNICAL DATA - STANDARD CONFIGURATION. Stainless steel, exchangeable and washable. Compressor

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

MCV - MCH - MCHZ Multistage pumps

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

Sierra Europe Srlu Technical Specification AL5000 mobile baler

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

Technical Parameter: Suction Diameter: 40~250 mm Discharge Diameter: 25~200 mm

All rights reserved! P/N REV 01 P1

B.K. Machinery (M) Sdn. Bhd. Submersible Pumps. Flexible Vibrator Poker. 1 of 6. Other Construction Machinery

PUMPS AND PROP AGITATORS

Air cooled industrial chillers

These reasons speak for the pumps from Wacker Neuson. Pump expertise in detail. Overview of all pumps.

1600 Series Rotating Suction Screen

CLOSED COUPLED CENTRIFUGAL PUMPS

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Ruhrpumpen Fire Systems

IMMERSIBLE PUMPS FOR INDUSTRY


HD 5/12 C Plus. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle.

MARLOW PUMPS RECIRCULATION

HD Kompakt Service Manual

HD 5/12 C + Mobility. Accessory storage

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

CombiPrime Self-priming centrifugal pumps

V80-H Multistage Pump Instruction Manual

dp pumps the dynamics of water HVAC centrifugal (norm) pumps

6-30 Vertical Deep Well. Close Coupled Vertical Turbine Submersible Turbine. Pump Type. Application. Description. Materials

teambrite Supply Steambrite Supply Created on: : Thursday 18 April, 2019

Roto-Jet I & II Tube Cleaning Systems

MACHINES ACR SERIES ACR RAMMER

Cold water HD 9/18-4 ST

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

Cleaning Equipment. Table of Contents. Fuel Injection Pump Cleaning Pressure Washers Blasting Equipment Miscellaneous...

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

FLANGE-MOUNT CENTRIFUGAL PUMPS

Submersible Supply Pump Packages

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

Cold water compact class HD 5/12 C

Hand pump JP-02. Hand pump JP-02 for acids, alkalies and water-based chemicals. depending on lever position. The telescopic suction tube is adjustable

Machine Tool Coolant Units

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Hot water super class HDS 12/18 4S *AU

GFT-060/40/H2. Designed and built According AD-2000 regulation Homologation and branded CE According to the European Directive CE

DRY BULK HANDLING SYSTEM

Portable Petrol Powered

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

With combustion engine HD 801 B. Equipment: Trigger gun Extended highpressure. Technical data

dp pumps the dynamics of water HVAC centrifugal (norm) pumps

- Sewage and Sludge Pumps

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

TECHNICAL DESCRIPTION

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

PORTABLE HYDRANT PN10 1A; 2A; 1B; 2B; 1C; 2C TYPES

INDUSTRIAL AND MARINE PUMPING SOLUTIONS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

Direct Fired Heater Model AD Specification

Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 10, 16, 25, 43 kw

MODERN TECHNOLOGIES AND LONG - TERM EXPERIENCE

ERGONOMIC TECHNOLOGY. 1

POULTRY MARKET CATALOG

Hakki Pilke Raven spare parts manual

SPRINKLER SYSTEM SOLUTIONS. Water-based Fire-Fighting Sprinkler System PROVEN TECHNOLOGY

HOT WATER HIGH PRESSURE WASHER ON TRAILER COLORADO 350 (Mounted in a Waterkracht double-axe-trailer)

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

HD 7/11-4 Cage Classic

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

MODEL CMA-130VL PARTS MANUAL Rev 1.00

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

PRO JET RANGE FOR A PRODUCTIVE, CLEAN & HEALTHY WORK ENVIRONMENT

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

CODE DESCRIPTION QUANTITY UNIT OF MEASURE

FANERGY Far more than just a fan.

PDF # GRUNDFOS END SUCTION PUMP EBOOK

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U )

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

PolyRex polymer make-up unit, vacuum conveyor support Technical specification

HD 6/13 C. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 3 Accessory storage

Granule Gastro/Combi

Pumps SELECTION OF A PUMP

Transcription:

Residential Fire Fighting Booster Systems

Experience With our R&D, production, and installation experience of more than 35 years in the pump technologies field, we protect you and your investments without compromising from quality with our expert sales and after-sales services. Green Engineering By blending advanced pump specifications with innovative technologies, we offer highquality, high-performance, energy-efficient, environmentally-friendly, and low-cost products to the end users. We offer complete solutions for building infrastructures with our wide product range including in-line dry rotor circulating pumps, endsuction norm pumps, horizontal-vertical multistage centrifuge pumps, waste water drainage pumps, booster systems for residential and commercial buildings, fire pumps, and booster systems in line with TSE EN 12845 and NFPA 20 norms under the brand of ETNA. ETNA, which set off with the vision of offering sustainable products, is preferred in prestigious projects in both Turkey and the world, and is used reliably. 2

ETNA Residential Fire-Fighting Boosters Reliable pressure water supply in fire-fighting systems In case of fire, reliable pressure water supply is the most important and crucial thing. The fire-fighting system that will be activated automatically while the file is only at its initial phase is expected to create a wet zone (an escape corridor) and to begin running immediately and flawlessly as a precaution against the spread of fire instead of extinguishing it. Only a system that can deliver water to the fire zone or floor of the building in a sufficient amount and required pressure would be effective in the fight against fire. We always consider this while designing and manufacturing Exact Answer to Your Needs ETNA residential fire-fighting booster systems feature a protection control panel with audio - light warning (alarm kit) and a weekly test system in their double pump design with 100% back-ups or triple pump design each fulfilling 50% capacity in line with the regulations. Thanks to the wide product range in terms of hydraulic performance (12-43 m 3 /h flow & 80-90 mss pressure) and package system (chassis, suctiondelivery collectors, pressure switches, floaters etc.), there is definitely an ETNA solution that will fulfill your need. our products in order to protect you and your investments. 3 www.etna.com.tr

Residential Fire-Fighting Boosters Y2 KO Series Applicable for fire-fighting systems of residential buildings such as houses and blocks of apartments etc. The general practice in Turkey according to the fire regulation requires storage of water sufficient for minimum 1 (one) hour until the fire brigade accesses the location of fire; and minimum 2 (two) fire cabinets in the building are required to be active and functional. According to the provisions of the "Regulation on Protecting Buildings from Fire", each fire cabinet is required to have 100 L/min. flow rate, and the last fire hose nozzle is to have 40 mss (4bar) pressure. The fire water booster systems, which satisfy this quality, are chosen in general to satisfy the hydraulic levels of 2x12 m³/h & 80-90 mss. Product Specifications Pump Body and Shaft : Stainless Steel (AISI 304) Fan and Diffusers : Norly Mechanical Seal : Carbon / Ceramic / NBR Inlet-Outlet Body : Cast Iron (GG25) / Bronze (Optional) Special bronze bushing resistant to operation without water Fully automatic electrical panel (sound and light alarm) 5m level floater that prevents the device running without water Suction and delivery collector Spring-type stainless steel check valve Manometer and pressure switch Steel frame with anti-vibration rubber chock and oven-dye Weekly test system NOTE: Jokey (pilot) pump is optionally added to the EPH B/C series water booster system in a compatible flow rate and pressure. CAUTION: The use of recommended balance tank volume (100L) is only suitable when the system is used for fire-fighting. Flex hose is not recommended for pressures equal to or higher than 16 bars. There is no thermal protection in the electrical engines of fire-fighting boosters as required by the fire regulation and the respective norms. Thus, the fire pressure boosters should not be used to pressurize utility water. In case of use other than its intended purpose, the fire-fighting boosters will be out of warranty. Y2 KO 10 / 7-30 Motor Engine Gücü Power (kw) / / Değer Value x 10 Pompa Pump Stage Kademe Count Sayısı Pompa Pump Series Serisi (m 3 ) 3 ) Pompa Pump Modeli Çift Double Pompalı Pump Yangın Fire-fighting Hidroforu Booster 4

Diesel / Engine Pump Fire-Fighting Boosters YKO + D10 Series Residential water booster system for fire with alternative power supply (diesel) in case of power cut. Applicable for fire-fighting systems of commercial buildings such as houses and blocks of apartments etc. Product Specifications The set is composed of a diesel and an electrical engine pump (Pilot (jokey) pump is optional). It is provided as a set on a powder-coated chassis with pumps connected to each other with manifold, a compensator, ball valves, check valves, individual pressure switches and a control panel with weekly test cycle. Operating Principles The pump is activated when there is a pressure drop in the system. And the diesel engine pump is automatically activated when the power is cut or the water demand increases. Suitable for systems containing fire cabinets. Automatic test system is available. Connection flex and balancing tank excluded. Diesel Pump Specifications Electrical Pump Specifications Multi-level, vertical-type pump Pump Inlet-Outlet Body: Cast Pig Iron Pump Body: Stainless Steel (AISI 304) Pump shaft: Stainless Steel (AISI 304) Mechanical seal Pump Fan: Hardened Norly Capacity: 8 bar x 12 m 3 /h Voltage: 380 V 50 Hz STREAM 10 HP, 3600 rpm, air cooled engine Manual operation Electrical start/stop 14L independent fuel tank 12V DC battery Oil pressure safety Monoblock, single-level, centrifugal pump Pump body: Cast Iron Pump fan: Aluminum Mechanical seal Self-priming pump Inlet-Outlet Diameters: 2 Pump capacity: 12 m 3 /h - 6.5 Bar NOTE: Jokey (pilot) pump is optional and should be added to the system as T 1 EPH B/12 model water booster. CAUTION: The use of recommended balance tank volume (100L) is only suitable when the system is used for fire-fighting. Flex hose is not recommended for pressures equal to or higher than 16 bars. There is no thermal protection in the electrical engines of fire-fighting boosters as required by the fire regulation and the respective norms. Thus, the fire pressure boosters should not be used to pressurize utility water. In case of use other than its intended purpose, the fire-fighting boosters will be out of warranty. Y KO 10 / 7 30 / D10 + T 1 EPH B /12 Jokey Pompa Pump Modeli Dizel Diesel Pompa Pump Modeli Motor Engine Gücü Power (kw) (kw) / / Değer Value x 10 Pompa Pump Stage Kademe Count Sayısı Pompa Pump Series Serisi (m 3 ) 3 ) Pompa Pump Modeli Yangın Fire Pressure Hidroforu Booster 5 www.etna.com.tr

Oil / Electrical Engine Fire-Fighting Boosters YKO + B10 Series Residential water booster system for fire with alternative power supply (oil) in case of power cut. Applicable for fire-fighting systems of commercial buildings such as houses and blocks of apartments etc. Product Specifications The set is composed of an oil and an electrical engine pump (Pilot (jokey) pump is optional). It is provided as a set on a powder-coated chassis with pumps connected to each other with manifold, a compensator, ball valves, check valves, individual pressure switches and a control panel with weekly test cycle. Operating Principles The pilot pump is activated when there is a pressure drop in the system. If the targeted pressure cannot be reached, the electrical pump is activated. And the oil engine pump is automatically activated when the power is cut or the water demand increases. Suitable for systems containing fire cabinets. Automatic test system is available. Connection flex and balancing tank excluded. Electrically Driven Pump Specifications 4 HP, 3000 rpm, electrical engine Multi-level KO 15/5 horizontal pump Pump Inlet-Outlet Body: Cast Pig Iron Pump Body: Stainless Steel (AISI 304) Pump shaft: Stainless Steel (AISI 304) Mechanical seal Pump levels reinforced noryl Capacity: 6.5 bar x 12 m 3 /h Voltage: 380V-50 Hz Pilot Pump Pilot pump offsets the water leaks and the pressure drops in the system. Oil Pump Specifications HONDA 10 HP, 3600 rpm, air cooled engine 4 cycle, single cylinder, oil engine Manual operation Start and stop with electrical starter 5L independent fuel tank 12VDC battery Low oil pressure protection Overheating protection Automatic choke for easy operation Multi-level KO 15/5 horizontal pump Pump Inlet and Outlet Bodies: Painted Cast Pig Iron Pump Body: Stainless Steel (AISI 304) Pump Shaft: Stainless Steel (AISI 304) Mechanical Seal Pump levels reinforced noryl Capacity: 6.5 bar x 12 m 3 /h NOTE: Pilot (jokey) pump is provided with the product. CAUTION: The use of recommended balance tank volume (100L) is only suitable when the system is used for fire-fighting. Flex hose is not recommended for pressures equal to or higher than 16 bars. There are no "Thermal Magnetic Switches on the control panels of fire pressure boosters. Thus, the fire pressure boosters should not be used to pressurize utility water. In case of use other than its intended purpose, the fire-fighting boosters will be out of warranty. Y KO 15 / 5 30 / B10 + PM 90 Jokey Pompa Pump Modeli Benzin Oil Pump Pompa Model Modeli Motor Engine Gücü Power (kw) (kw) / Değer / Value x 10 Pompa Pump Stage Kademe Count Sayısı Pompa Pump Series Serisi (m 3 ) 3 ) Pompa Pump Modeli 6 Yangın Fire Pressure Hidroforu Booster

Diesel Engine Mobile Fire Pump YPO-D10 Series Fully-equipped mobile fire-fighting system for local and residential use until the fire-fighting department reaches the site. Offered as a full set with a STREAM high-performing 10HP diesel engine, monoblock and single-level fire pump that delivers to 30-35m vertical distance with a pressure higher than 7 bars, manually controlled professional lens for easy handling of the fire hose, and 20m hose suitable for forest fire. This fire set may be used to easily draw water from pools, water tanks, lakes, lagoons, rivers, sea and other water sources. It has a wide area of use including residential fire-fighting, water discharge during floods etc. Accessories 2" 4m suction hose with 2" brass filtered vertical check-valve 20m, double-layer fire hose that is resistant to 12bar pressure and couplings at both ends Fire lens with flow and pressure control, and 30-35m spraying distance All connectors and couplings are in line with the industry and forest legislation. 2 wheeled carrier chassis Product Specifications STREAM 10 HP, 3600 rpm, air cooled engine 4 cycle, single cylinder, diesel engine Manual operation Electrical start/stop 14L independent fuel tank 12VDC battery Oil pressure safety Monoblock, single-level, centrifugal pump Pump Body: Cast Iron Pump Fan: Aluminum Mechanical seal Self-priming pump Inlet-Outlet Diameters: 2" Pump capacity: 12 m 3 /h - 7 Bar 7

After-Sales Services We are here for you with our more than 35 years of sector experience, 92 service points all around Turkey, and customer-oriented after-sales service approach (commissioning, maintenance and repair, spare part supply). Dudullu Organized Industrial Zone Street 2 No. 14 34775 Ümraniye - Istanbul / Turkey Tel. +90 216 561 47 74 (Pbx) Fax. +90 (216) 561 47 50 www.etna.com.tr info@etna.com.tr customer service