Acoustic door holder fitting instructions

Similar documents
Salamander User Guide

Operating Guide. English Version 3.3

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Fitting and Operating Guide. plus. Maintenance Test Record

Fitting and Operating Guide. plus. Maintenance Test Record

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

Control Panel User Guide

Keep this guide in a safe place. Contents

SECURIT 700L USER MANUAL

CPVan Home Alarm Starter Kit

Digital Room Thermostat

DISABLED TOILET / EMERGENCY ASSISTANCE ALARMS

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

USER GUIDE. Security Control Panels INS046-7

Fitting and Operating Guide plus Maintenance Test Record

Smoke Detector and Siren. Manual

Fire Alarm Control Panel. System Maintenance and Log Book

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

U S E R M A N U A L UBH1RF HEAT ALARM

THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels

EMERGENCY ASSISTANCE ALARMS

Operating Instructions Version 1.2

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Public Address and Voice Alarm. Version 1 DESIGN & INSTALLATION GUIDE

CSP-204 CSP-208 CSP-104 CSP-108

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.

FIRE ALARMS EMERGENCY LIGHTS NURSE CALL ACCESS CONTROL GK FIRE & SECURITY LTD, UNIT 1 GREBE RD, PRIORSWOOD IND EST, TAUNTON, TA2 8PZ

Conventional Fire Detection

abode Web app Functionality

LS800S Intruder Alarm System. Engineering Manual

Installation and user guide

SECURIT 703 USER MANUAL

Scantronic Leading the way in security

Using Your. Security System With LED Keypad S5030, S5031, S5032

USER GUIDE HARDWIRED CONTROL PANELS

HARDWIRED CONTROL PANELS

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

C-Stat 17-ZW User Instructions

USER GUIDE HARDWIRED CONTROL PANELS

Galaxy Flex V3. User Guide. Honeywell Security. This user manual is located at

HARDWIRED CONTROL PANELS

PiSector GSM Cellular Wireless Alarm System

DXL ALA Settings Guide

Fitting and Operating Guide plus Maintenance Test Record

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

Danfoss ECO. The easy way to Smart Heating

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

User Operation Guide Document: VI49.2

USER MANUAL CEF AP28 CONTROL PANEL

OWNER S GUIDE TYPE A TYPE C TYPE B TYPE E TYPE F TYPE D COOL FAN OFF. CA Series << FAN SPEED COOL FAN AUTO SLEEP TIMER FAN SPEED

LIFETONE HL TM. Bedside Fire Alarm & Clock. User s Manual MODEL HLAC XI. RECOMMENDED LOCATIONS FOR SMOKE ALARMS ENGLISH SPANISH

RF Programmable Room Thermostat User Instructions

CS027 User Instructions

ADE Gen4. Speech Dialler Engineering Information. Description. Features

3 ZONE WIREFREE BURGLAR ALARM INSTALLATION & OPERATING INSTRUCTIONS

XP95 Sounder VAD Base

Alarm System SECURE AS 302

ZP3 Operator & Maintenance Manual Version 1

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Digital Electronic Thermostat With RF

AXS Strikemaster Engineering Manual

SCS311 / SCS317 Installation Instructions

SOUNDER CONTROL MODULE SCM-AS4

Lifeline 400 user guide q6 18/2/04 10:56 am Page 2. Lifeline 400. installation and user guide. Part Number D B

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

Intelligent Security & Fire Ltd

USER GUIDE HARDWIRED CONTROL PANELS

POP_ Smoke Detector

M800, M800iD Plus, M1000 and M3000. User's Guide

Maintenance Guide EMS Security Group Ltd. All rights reserved. MK154 Iss5 18/11/15 AJM

Deaf & Hearing Impaired RadioLINK Alarm System

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Security System. User Guide for the LED Command Center

POP_ Smoke Detector

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Pool Protector OPERATING INSTRUCTIONS MANUAL

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

Xenex Conventional Fire Detection & Alarm System

Control Panel User Guide (TO BE RETAINED BY THE USER)

2200 and 2200L ALARM CONTROL SYSTEMS

External Wireless Sounder

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

WIRELESS DOOR/WINDOW CONTACT ACCESSORY (WHA3)

HSA % wirefree security alarm system. Installation Programming Operating. Helpline Intelligent Security & Fire Ltd

INSTALLATION MANUAL SOUNDER MODELS RIALTO L LS X LSX TRIADE L LS QL QLS LIDO L X LS LSX

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

Digital Electronic Thermostat With RF

Movement Detector GJD 300

Premium 8 Zone Wireless Alarm Kit

PRODUCTS. Operating Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL

Transcription:

Acoustic door holder fitting instructions Fitting the holder Decide where the door holder will be mounted (at least 650 mm from the door hinge). For doors fitted with overhead closers, a position towards the top of the door is best. Mark the position for the keeper plate on the door. Use the paper template supplied to drill holes in the wall. Remove the lid and fit the holder securely to the wall using three screws. Check the rubber ring is fitted before screwing the keeper plate to the door. Screw the keeper plate onto the door. Fit the supplied batteries (2 x C cells). Note, the correct orientation is marked in the battery compartment. The motor will turn for around five seconds. Fit the lid. The red dot will illuminate and after 10 seconds the magnet will turn on, providing the background noise is low. You must now teach the holder the alarm sound as explained in the Learning the Alarm section (see page 2). Align the keeper plate with the magnet face. If the holder is fitted to a left hand door, command option 2 may be selected to make the display easier to read (see page 3). Do not put the door holder into use without performing a fire test to check that the door releases. Refer to the testing section. 1-11-9486 Issue H 1

Sounder locations When fitting an Agrippa door holder, take note of where the nearest sounder is. If there is a door between this unit and the nearest sounder, before following the Learning the Alarm section, make sure the door between the unit and the sounder is closed so that the unit is learnt in the worst case ensuring it releases in a fire. Learning the alarm Remove the lid and press ENT. The display will show 0. The display changes to show that it is recording. This takes around 15 seconds. The door will release once the recording has finished. You can now switch off the alarm. The holder takes another two minutes to process the sound. This is indicated by the rotating pattern on the display. Once the red dot lights, the door holder is ready to use. Press INC and the display will show 1. Press ENT to select option 1. Three flashing lines show that it is ready to learn. Put the lid on the holder. Open the door until it is held by the magnet (the lid must be fitted before the magnet will turn on). The unit is ready to learn. Sound the fire alarm and press the red release button to start recording. There must be no background noise while the alarm is recording. N.B. If the unit is left for more than 20 minutes in option 1 without starting the learn cycle, the learn mode will time out. Bells as alarms If the alarm sound is generated by a bell, you may find that the Agrippa is sensitive to general background noise after the learning process. The red dot will often stay lit and the door may not hold or release. This can be improved by removing the lid and selecting command option 9 (see page 3). This can be done any time after completing the learning process as long as the Agrippa has not been returned to default settings. Once selected, the display will show a rotating pattern for around 10 seconds. Replace the lid. If the holder has already been returned to default settings, you will have to repeat the learning process before selecting option 9. Noisy doors and keepers When doors are near to each other, note whether any of the doors make a noise when closing whether due to the closing mechanism, the door slamming shut, or a chain keeper knocking against 2

the door surface. If this is the case, doors need to be put through the learn cycle separately to stop a unit hearing this noise and having the noise skew its sound processing. Daily timed release You can set a daily time when the door holder will release. It will then stay released until another set time when it will reactivate. Times are entered in 24 hour format. The current time, release time and a resume-hold time must be set before this function will work. If the batteries are removed, the current time must be reset. To set the current time, remove the lid then press the ENT button. 0 is displayed. Press the INC button until 4 is displayed. Press ENT and 4 will flash. This example shows how to enter a time of 3:20 pm or 15:20. Press the INC button until 1 is displayed. Press ENT. The tens of hours is now set. Press the INC button until 5 is displayed. Press ENT. The hour is now set. Press the INC button until 2 is displayed. Press ENT. The tens of minutes is now set. Press the INC button until 0 is displayed. Press ENT. The time is now set and the display is blank. Now set the release time using command option 5 and the resume-hold time using command option 6. Enter the time in the same way as shown above. Command option 7 can be used to check the times that have been set. Select this option to display the current time, the release time and the resume-hold time. The 12 digits are displayed sequentially. Refit the lid when complete. Release/reset button If the magnet is holding normally, pressing the red button will release the door. The display will show the battery level. If the holder is not magnetised, press the red button to reset. The display will show why the magnet is off. If, after 10 seconds of listening, no alarm is detected (and the holder is not in timed release or low battery) the magnet will turn on. Command options Remove the lid and press the ENT button to enter command mode. Press the INC button until the number for the required option is displayed then press ENT to select that option. Option 1. Learn - see over page. Option 2. Use this option if the numbers on the display are upside down. Option 3. Restore default settings with a level of approximately 70dB. This will replace any settings previously entered. Option 4. Set time - enter the current time in 24 hour format. Note that this must be re-set if the batteries are removed. Option 5. Release time - enter the time at which the magnet will release. Enter 0000 to cancel. Option 6. Resume-hold time - enter the time at which the magnet will turn back on. Option 7. Display time - display the current time, the release time and the resume-hold time. Option 8. Set release setting to approximately 65dB. This will replace any previous settings. Note that at this low sound level, the unit is susceptible to false releases from background noise. Option 9. Alarm bell setting. Use if the alarm sound is produced by a bell and the holder is too sensitive to background noise. Only select after the learning process has been completed (see page 2). For a step by step video fitting tutorial, visit our vimeo account at: www.vimeo.com/geofire 3

Display messages The messages shown when the red button is pressed are below. You may need to select option 2 to turn the display the right way up. New batteries will display b9. If b0 is shown, fit new batteries. A flashing bl indicates the batteries are critically low. The door will not hold until the batteries are replaced. Flashing A. The door is released because of an alarm. Flashing F. The door is released due to a timed release. Flashing E followed by 1. The batteries are too low to learn the the alarm sound. Flashing E followed by 2. The lid has not been fitted for recording the alarm sound. Flashing E followed by 3. The red button has not been pressed to start the learn process within 20 minutes. Flashing E followed by 4. The sound level detected in the learn process is below 65dB and the default parameters of 70dB have been used. Flashing E followed by 5. The sound level detected in the learn process was found to be intermittent but its timing could not be identified. The sound levels detected are set but the holder may be slow in waking up. It is recommended a different alarm pattern is used on the sounder. Flashing E followed by 6. The intermittent sound level detected during the learn process is below 65dB and the default parameters of 70dB have been used. Flashing E followed by 7. The unit has not been put through the learn cycle or has been set back to default settings. Perform a learn process before choosing option 9 (see learning the alarm). Testing 1. Open the door so that it is held by the door holder. 2. Check that any doors between the holder and the nearest fire sounder are closed. 3. Sound the fire alarm. 4. The holder will release within 20 seconds. 5. Check that the door closes fully. 6. Press the red button to reset the magnet. If the button is not pressed, the holder will reset automatically after 30 minutes. 7. If the door does not release, follow the instructions in the learning process section. The test can be accelerated by holding the red release button for four seconds. After 10 seconds, the red dot will flash every second. In this mode the holder will respond to a typical alarm sound in about five seconds. The holder will return to normal operation after it has detected an alarm or five minutes after the button is pressed. Maintenance Check all fire doors release and close as part of a weekly fire test routine. In normal operation, the holder will release within 20 seconds of the alarm sounding. Replace the batteries annually or when indicated by a low battery warning. Simply remove the cover, remove the old batteries, and replace with new batteries. The unit will hold automatically when the cover is replaced and the unit has detected a quiet state. There is no need to put the unit through the learn cycle again. If a release time has been programmed, the current time will need to be entered as per the Daily Timed Release section. Keep the faces of the magnet and keeper plate clean and free from damage. Specification Holding force 200N Power 2 x alkaline C Cells Typical battery life 12 months + Default Release Volume 70 db Patented in the United Kingdom under patent number 2507582 Stephenson Stephenson Gobin Gobin Ltd L td Bishop Auckland Bishop Auckland DL14 6XB England DL14 0HY England 5 5 1121 -CPD-AE0019. EN1155:1997 EN115:1997+A1:2002 + 3 1 1 0 13 4

INNOVATORS OF FIRE TECHNOLOGY AGRIPPA ACOUSTIC DIGITAL DOOR HOLDER DIGITAL ACOUSTICALLY TRIGGERED DOOR HOLDER LEARNS THE SOUND OF YOUR FIRE ALARM EASY, WIRE FREE INSTALLATION AND PROGRAMMING DAILY TIMED RELEASE OPTION 200 N HOLDING FORCE TWO ALKALINE C CELL BATTERIES listens & learns APPROVED TO EN1155 AND CE MARKED The Agrippa door holder learns the sound of your specific fire alarm, releasing the door in the event of a fire. This new innovation in the industry is also wire free, so it can easily be retrofitted to any door. The releasing trigger reacts to a particular sound rather than simply a loud noise, significantly reducing false activations. The holder is easy to install, only requires C cell batteries (which last for 12 months) and can be programmed for daily release. Suitable for installation to BS 7273-4 Standard Actuation (Category B). Other features include a seven segment LED display, manual release button and a low battery warning display. Ideally suited to environments such as care homes, schools and hospitals where it is essential to have doors in an open position at certain times of the day to aid access, but equally as important to ensure the doors are closed in the event of a fire. The holder is part of the Agrippa suite of products, which also includes an acoustically triggered fire door closer. Part Number : 3-80-0060 INNOVATORS OF FIRE TECHNOLOGY Holding force TECHNICAL INFORMATION Power size 5 Default setting 200 N 70dBA, 1.2-3.0 khz Preferred sounder Continuous tone * Dimensions L-118 x W-102 x D-66 Standard finish Finish White Part number Standard white 3-80-0060 Polished brass 3-80-0062 Black 3-80-0066 * Not suitable for voice alarm systems Patented in the United Kingdom under patent number 2507582 Keeper Plate Stephenson Gobin 20 Longfield Road, South Church Enterprise Park, Bishop Auckland, County Durham, UK, DL14 6XB Tel: +44 (0)1388 770 360 Fax: +44 (0)1388 779 197 Email: enquiries@geofire.co.uk Web: www.geofire.co.uk Geofire reserve the right to change the specifications in this data sheet without prior notification