Instruction Cum User Manual For EUROLITE

Similar documents
MODEL 7000 SUCTION UNIT

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

Instructions. Portable Absorb Phlegm. Apparatus

ASPIRE Laboratory Aspirator

CONSTANT SUCTION UNIT

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

BIOVAC 500 SMOKE EVACUATOR

ELITE (110V) (220V)

HERCULES (110V) (220V) USER S MANUAL

Instructions for use Vacuum regulation valve with water trap

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

Dyna-Form Air. Alternating Pressure Relief Overlay System

SUCTION UNIT SUCTION UNIT

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

V80-H Multistage Pump Instruction Manual

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

INSTRUCTIONS FOR OPERATION AND CARE OF

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

USER MANUAL UN-200V / UN-200VH

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

ANTIBACTERIAL HAND VAC WITH UV LIGHT

Operating Instructions

Manual Page 1 of 8. Manual. Laboratory autoclave

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

Xaact Spot. Xaact Hot Spot

INSTANT WATER HEATER INSTANO 1L / 3L (Litre)

Suction Pump F-30.xx

5. Instrument and accessories discharging must be done following current law regulations in every country of use.

PRO 2000i LOW LEVEL DEPOSITOR

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

INSTRUCTIONS SUCTION PUMP. CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician.

OPERATION MANUAL. LED Coupling OM-TR355E. Please read this operation manual carefully and file for future reference.

THE BLACK PROVAC BACK PACK VACUUM CLEANER

Installation and Operating Instructions for Davey BF Series Pressure Booster Systems with Flow Switch Control

INSTRUCTION MANUAL FOR MINI SUCTION UNIT

ANTIBACTERIAL HAND VAC

BEFORE OPERATING THE MACHINE: WARNING

USER MANUAL AND TECHNICAL MANUAL

INSTRUCTIONS AND WARRANTY

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

SEPTIC FLUID ASPIRATOR MEDAP-VENTA SP 26 N MEDAP-VENTA SP 26 A

ATMOS Surgical Suction

INSTRUCTION MANUAL Model: SU3022

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

LEC L6014W/S User Manual

CRISTAL Built-in Dish Sterilizer Instruction Manual

UL U TR LTRASONIC S ONIC SCALE ALER PIEZO MINI

User Guide. Please read carefully before use. Your Hoover Guarantee. Your Hoover Guarantee. Contents. IMPORTANT Safety Reminders

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

Installation and Operating Instructions

Suction unit Victoria

*smith&nephew VERSAJET HYDROSURGERY SYSTEM

SUCTION PUMPS CareLinc Home Medical Equipment and Supply, LLC SS170CE00101

Operating and Maintenance Manual. Scout and Sentinel Vacuum Regulators

EL400 OPERATION MANUAL

Commercial backpack vacuum cleaner

Instructions For Use ENG. LED Magnifier Lamp

X99 Series. Dental Handpiece. Instruction For Use

Light oil / kerosene burner

Basic SURGICAL SUCTION PUMP. EN Instructions for use

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

SIMPLY UNCOMPLICATED TANNING SYSTEMS Training Manual

This symbol indicates an insulation class I device. This Symbol indicates a type B applied part. This symbol indicates alternate current

SUBMERSIBLE WATER PUMPS

100 Series Maxi Internal Filters

Emergency Systems Bolzano - Italy SUCTION UNIT CATALOGUE

INSTRUCTION MANUAL DRY IRON

VADA - Rain2Main Automatic Rainwater Controller

TEMPLATE Standard Operational Guideline RX Air 3000 Air Purifier

Gas Fire Patio Heater Q9

Surgical Suction: Silent and powerful!

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12 Task Force Pneumatic Portable Dental System

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

DELUXE ALTERNATING PRESSURE SYSTEM USER GUIDE

Tempest TP420/180 Electric Pressure Washer

Dear Valued Customer:

RVTM3 SUCTION VACUUM REGULATORS

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

Table of Contents. English

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

User Manual standard for Medical Electrical. Control Number 95CG. Classified by. Underwriter s Laboratory Inc. for UL

Power 4. User Guide. HC85-P4-ZA hoover.za.com

RVTM3 SUCTION VACUUM REGULATORS

APW-VAP-150P High Pressure Cleaner Operator Manual

I N S T R U C T I O N S

INSTRUCTION MANUAL STEAM IRON NT14O123P-CS. Please read these instructions before using the appliance 1 / 7

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

Med-Aire Assure 5 Air + 3 Foam Base Alternating Pressure and Low Air Loss Mattress System

INSTRUCTION MANUAL. Instruction Manual High Throughput Homogenizer

INSTALLATION AND OPERATING INSTRUCTIONS

Rice Cooker GL 3056 GL User s Guide

OMNIVAC secretion aspiration system Description of device and instructions for use

OWNER'S MANUAL Model VPW46H 120V., 60 Hz., 13 Amps. PRESSURE WASHER. FANTOM 94 Main Mill Street, Door 16 Plattsburgh, NY Tel.

SOLUS-500 EXTRACTOR 120V

Instruction Manual. Oil Filled Radiator. Model No.: OFR 3211F PTC

Transcription:

An ISO 9001:2008, 13485: 2012 Certified Company Instruction Cum User Manual Bacterial Filter Vacuum Gauge Connector for Patient use Float Valve Hi/Low Switch On/Off Switch Vacuum Control Knob 1 Ltr PC Jar ABS Enclosure Dear Customer, Congratulations on your purchase of this versatile and need oriented suction unit. It will serve you well for years, if properly looked after. The medical professions have long felt the need for a lightweight, easy-to-move, safe, dependable and easy-to-regulate suction unit. EUROLITE fills this healthcare need to a degree unmatched by any other unit. It is designed for light use in hospitals, nursing homes doctor's offices, pediatric care, ICU's and home care. Non corrosive and shockproof enclosure is pressure moulded in engineering plastic ABS giving smooth and easy-to-clean surface. ASSEMBLY The pump is housed in the enclosure. The second nozzle is marked 'patient' and the tubing from this goes to the patient. The release valve for adjusting the negative pressure and the vacuum gauge are on the panel. An on/off switch cum pilot lamp, fuse and the removable main lead connector are on the side. Before the unit is put on please see that : 1. Jar is checked for possible crack or flawed spots. Any defect can result in implosion under vacuum. w w w w. a. an na an nd di ni nd d. c. co om m Page - 1

2. Check the bacterial filter, and change the filter element if necessary. The housing must be flip tightened. 3. The lid and tube are tightly placed on the jar. To avoid leakage the push-in and angular connectors must be inserted as far as the stop. While unplugging, twist and pull. 4. The main power supply is well earthed. In case of fluctuation, use voltage stabilizer/corrector. 5. The vacuum control knob is not loose. It must be fully tightened clockwise. TECHNICAL Housing: Engineering moulded ABS plastic cabinet with built-in handle Capacity: 0-575 mm Hg ± 10 regulable at 14 ltrs/min. Hi/Low switch provides full or half vacuum with one flick Pump type: Oil-free piston pump Jar: One 1 ltr collection jar (Polycarbonate) with mechanical overflow shut-off system. Tubing: 8 mm ID x 2 mtr (PVC/Silicon) Vacuum Gauge: Bourden type 5 cms. 0-760mm Hg calibration Filter: Bacterial filter Power: 230V AC, 50 Hz, 60 watts. (110V on request) Dimension & Weight: 33 x 14 x 29 cms. 3.5 kg. Ideal for homecare, clinics, labour rooms and minor OTs VACUUM AT ALTITUDES The specified maximum vacuum refers to sea level. According to local conditions, and barometric pressure, slight deviations in vacuum reading may be noted. As a reference, the table below shows several factors by which the indicated maximum vacuum value must be multiplied, according to the altitude of location where the measurement is carried out. Location/Maximum Vacuum Location Sea level 1000m 2000m 4000m Factor 1.00 0.88 0.78 0.60 GUIDELINES FOR USE Negative Pressure: Before the unit is put to use, required vacuum must be set by occluding the nozzle and controlling the release valve. Fully tightened (clockwise) vacuum control knob means full vacuum. Jars/Tubings: The material of the jars polycarbonate (PC) is superior to glass. It is less fragile when subjected to impact and less sensitive to temperature shock. PC is resistant upto 120 C provided it is not subjected to any physical loading. As the flow rate is high 3/4 filling of the jar is recommended. The lid has a built-in antifrothing device. The jar is easier to clean if a little water or disinfectant is put into it prior to suction operation. The safety jar must, however, remain dry. Tubing after repeated use can be brittle and must be changed. 1 Ltr PC Jar Page - 2

Cleaning and Disinfecting: After each use, jars, lids, overflow cut off valve, catheters, etc. should be cleaned thoroughly. When cleaning is necessary after infective fluid has been evacuated, the jars, lids, cut off valve and tubing can be sterilized by autoclaving upto 120 C for 20 minutes. Alkaline cleaning agents and disinfectants based on phenyel may not be used. Adherence to hospital directives on hygiene is of prime importance. The instructions provided by the suppliers of cleaning agents as well as by the manufactures of sterilization and/or disinfection units must also be followed, where application, temperature, process duration and airing, etc. are concerned. PUMP The unit is fitted with Piston type oil-free pump, provides reduced maintenance cost. a) Open the unit with the aid of an allen key provided and disconnect the tube from the inlet point on the pump housing. b) Take out the motorized pump fitted on (and together with) the platform. c) The fly valves sheet is placed in the top the four screws of which can be opened-one for vacuum and the other for outlet. The piston is fitted below the top and over the eccentrically rotated came. Just wipe clean these parts and set the unit again. d) There are two openings (small and U type large) in both the top portions. While fitting see that large U of the one face towards the small round of the other and small of the first face the large of the screws can be put back and tightened in their positions. e) Please run the unit and see its satisfactory functioning before housing is screwed up. Bacterial Filter Pump Unlike the rotary design, NO LUBRICATION IS REQUIRED IN THIS PUMP. The unit has not to be tampered with by any mechanic other than our factory engineer, or the person authorized. Patient Sencer Filter Safety Jar Gauge Release Valve L Motor N Inlet Outlet E MOTORIZED PUMP Page - 3

TROUBLE SHOOTING: Problem Possible source of trouble Check/Action to be taken Motor does Not Run Power Supply Voltage, power socket Main switch Set at "ON" Electrical cord Plug type, plug connections, damaged cord The blood has entered the pump. The remedy is given above under pump cleaning Leak within the pump or in the external suction circuit Isolate the source of trouble by carrying out the checks outlined in. Inadequate Suction Performance External cause: Push-in connector O-rings/Lid gasket Push-in angular connectors Release Valve Tubing Lid Jar Bacteria filter housing Filter paper Condition No Leaks at tube ends Push in as far as stop. The Knob should be tightly placed Cracks, brittle areas Airtight fit jar Condition/Possible cracked edges/hairline cracks Condition/absence of leaks Condition/position of housing Blockage or kink in tubing within the Isolate source of trouble as follows: Vacuum gauge indicates a vacuum Pump does not suck, however pump or in the external suction circuit External cause: Bacteria filter overflow valve in the lid, (float valve) push-in connectors, tubing etc. Remove the tube from the inlet (vac) point on panel and leave the suction connection open. If the vacuum gauge now indicates zero vacuum, the cause is external Investigate the whole external suction circuit for blockage (s), float valve sticking, kinked tubing and rectify. If the vacuum gauge still indicates a vacuum, the cause is internal Page - 4

TERMS OF WARRANTY Anand Medicaids Private Limited warranty the high quality and workmanship of each Anand's HI-VAC for a period of one year subsequent to the date of delivery by the company. During this period, faulty material will be replaced free of charge. This warranty does not extend to components that are subject to wear and tear in the course of normal operation or due to improper treatment/maintenance as per instructions. Further conditions in accordance with international standard IEC 601.1 item 6.8.2b. The manufacturer is only responsible for effects on the safety, the reliability and the performance of the appliance if Installation, additions, adjustments, modifications or repairs are carried out by personnel authorized by the manufacturer The electrical installations within the room concerned satisfy the requirements laid down by IEC. The appliance is used in full accordance with the instruction manual which is solely a guide and no substitute for professional training. The safe and effective use of this product largely depends on the skill of the operator. We are not liable for any damages due to mishandling or improper and unauthorised use. The company reserve the right to change technical specifications, designations and catalogue numbers without prior notice. Note Ensure that your electrical wirings are well earthed with 1 line and 1 neutral phase and your voltage is between 220V 240V. 50 Hz. Ensure that the suction unit should not be lifted above human body level. Dispose of used product/packaging in safe manner so as not to harm stray cattle, children and environment. WARRANTEE WARRANTY CARD Model No. SN Date of Purchase: Dealer Name: Stamp : EC REP ANAND MEDICAIDS PRIVATE LIMITED (Regd. Office) 33/16, Punjabi Bagh (Extn.) New Delhi - 110026 [ India ] Tel : +(91)-(11)-25225225/25229206/42464264 Fax : +(91)-(11)-25225062, E mail: sales@anandind.com (Works) 1460 M.I.E., Bahadurgarh, Haryana -124507 [ India ] KALEIDOS SH. VIA PONTIOA, 4 2012, MILANO, ITALY. Page - 5