CHIMNEY RANGE HOODS MODELS VJ603302SS & VJ604302SS

Similar documents
VJ504302SS CHIMNEY RANGE HOOD

CHIMNEY RANGE HOODS MODELS VJ51030SS AND VJ51036SS

BDF SERIES ! INTENDED FOR DOMESTIC COOKING ONLY! READ AND SAVE THESE INSTRUCTIONS

VCS500 AND VCS550 SERIES

CC700 SERIES INTENDED FOR DOMESTIC COOKING ONLY

VCS500 AND VCS550 SERIES

WP29M SERIES INTENDED FOR DOMESTIC COOKING ONLY

Model KER222. BEST BY BROAN P.O. Box 140 Hartford, WI ENGLISH...3 FRANÇAIS...12 ESPAÑOL

PRO VENTILATION HOOD USE AND CARE GUIDE CLEANING, MAINTENANCE, AND MORE

Barcelona Collection. Use and handling instructions Mode d emploi et d entretien Instrucciones de uso y mantenimiento

XOE30 XOE36 READ AND SAVE THE INSTRUCTIONS FOR RESIDENTIAL COOKING ONLY

RM60000 SERIES INTENDED FOR DOMESTIC COOKING ONLY

Model U102I ENGLISH...2 FRANÇAIS...15 ESPAÑOL A. BEST BY BROAN, P. O. Box 140, Hartford, WI 53027

CLEANING & MAINTENANCE For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild d

UNDER CABINET RANGE HOOD

IU600ES SERIES INTENDED FOR DOMESTIC COOKING ONLY READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

64000 SERIES RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS

Imperial. Read Before Starting Installation!

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

EC62 SERIES INTENDED FOR DOMESTIC COOKING ONLY READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

Owner and Maintenance Guide for M Line Range Hoods with M600/M1200 Blowers


Use, Care, and Installation Guide

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

E64000LC SERIES ! INTENDED FOR DOMESTIC COOKING ONLY! READ AND SAVE THESE INSTRUCTIONS

Imperial Cal Products, Inc.

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

Imperial. Cal. Products, Inc. Installation Instructions & Warranty Information. 425 Apollo Street Brea, CA

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

Owner and Maintenance Guide Models Equipped with K250 Blower

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Pro Ventilation Hood Liners

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Section 1 - Safety Information Section 2 - Installation: Wall Mount Hoods Section 3 - Installation: Island Mount Hoods

IVI WARNINGS: Must be followed carefully to avoid personal injury. [VL

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

READ AND SAVE THESE INSTRUCTIONS COOKING ONLY.! WARNING

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

Wall Mounted Hoods. Use & Care Page 6. Installation Instructions Page 4. Warranty & Registration Page 9

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

Use and Care & Installation Guide

APPUZO RANGE HOOD INSTALLATION

User s Manual WS-5830SS WS-5836SS WS-5842SS

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

WS-5530SS WS-5536SS WS-5542SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-68N30SS WS-68N36SS WS-68N42SS

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.

User s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

READ AND SAVE THESE INSTRUCTIONS

Cooktop Low-Profile Ventilation Hoods

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

Surface Is. ASL-E42ASX ASL-E48ASX RANGE HOOD - Installation instructions

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

2 Finding Information

Bosch ventilation use and care manual DPH36652UC - DPH30652UC

Professional Built-In Hoods

Self-Cleaning Range Hoods

! INTENDED FOR DOMESTIC COOKING ONLY!

READ AND SAVE THESE INSTRUCTIONS

RANGE HOOD. Model SEH5636G. FELIX STORCH, INC. 770 Garrison Avenue Bronx, New York

User s Manual HI30SS HI36SS HI42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

USER GUIDE - TOUCH GLASS CONTROLS

Installation Instructions Preference Wall Mount Range Hood

Operating and Installation Instructions

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

INSTALLATION INSTRUCTIONS &USE & CARE GUIDE AL-T7200 Versa BBQ Hood Series

GLASS DECORATIVE COOKER HOOD INSTRUCTION MANUAL READ AND SAVE THE MANUAL BEFORE INSTALLATION AND USE

Operation Manual RANGE HOOD

e Bath Fan with Light User s Guide

Kenmore Elite Range Hood

Tilt ATI-M90ASX ATI-M90ABX RANGE HOOD - Installation instructions

Integrated Hood Liner

RANGE HOODS. USER INSTRUCTIONS Model: Arca 30

Integrated Hood Liner

e Bath Fan with Light User s Guide

Use, Care, and Installation Guide

MH70230AS MH70236AS MH70248AS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind 7200 Series BBQ Hood

Viking Use & Care Manual

Bathroom Exhaust Fan/Fluorescent Light Combination

Model: GVA-I 668IS2 GVA-IS2 688I IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. FOR RESIDENTIAL USE ONLY.

Bathroom Exhaust Fan/Fluorescent Light Combination

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind P7200 Series BBQ Hood

Transcription:

INSTALLATION GUIDE HB0094 HB0095 CHIMNEY RANGE HOODS MODELS VJ603302SS & VJ604302SS INTENDED FOR DOMESTIC COOKING ONLY!! READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. HOMEOWNER: USE AND CARE INFORMATION ON PAGES 7 AND 8. Venmar Ventilation Inc., 550 Lemire Blvd., Drummondville QC J2C 7W9 1-800-567-3855 REGISTER YOUR PRODUCT ON LINE AT: www.bnv.ca For additional information - visit www.venmar.ca 09070 rev. 06

IMPORTANT SAFETY INSTRUCTIONS! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switch on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. Do not use this unit with any other solid-state speed control device. 8. To reduce the risk of fire, use only metal ductwork. 9. This unit must be grounded. 10. To provide protection against electric shock, connect to properly grounded outlets only. 11. When applicable local regulations comprise more restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expenses. TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high heat or when cooking flaming foods (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. d) Use proper pan size. Always use cookware appropriate for the size of the surface element. TO REDUCE THE RISK OF INJURY TO PERSON(S) IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*: 1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels This could cause a violent steam explosion. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher and you know how to operate it. B. The fire is small and contained in the area where it started. C. The fire department has been called. D. You can fight the fire with your back to an exit. * Based on Kitchen Fire Safety Tips published by NFPA. CAUTION 1. For indoor use only. 2. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 3. To avoid motor bearing damage and noisy and/or unbalanced impeller, keep drywall spray, construction dust, etc. off power unit. 4. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it will cool down. If the motor continues to shut off and restart, have the hood serviced. 5. The minimum hood distance above cooktop MUST NOT BE less than 26. For best capture of cooking impurities, the bottom of the hood should be at a maximum of 30 above cooking surface. For a gas range, the bottom of the hood MUST NOT BE LESS than 30 above cooktop. 6. Two installers are recommended because of the size of this hood. 7. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. 8. Because of the high exhausting capacity of this hood, you should make sure enough air is entering the house to replace exhausted air by opening a window close to or in the kitchen. 9. Please read specification label on product for further information and requirements. -2-

1. INSTALL DUCTWORK When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves. To reduce the risk of fire, use only metal ductwork. ROOF CAP Decide where the ductwork will run between the hood and the outside. 6 ROUND DUCT A straight, short duct run will allow the hood to perform most efficiently. Long duct runs, elbows and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs. Install wall cap or roof cap. Connect round metal ductwork to cap and work back towards the hood location. Use metal foil duct tape to seal the joints between ductwork sections. HOOD DECORATIVE FLUE WALL CAP ROUND ELBOW 26 MINIMUM ABOVE COOKING SURFACE (30 FOR GAS RANGE) HH0095A 2. MEASURE INSTALLATION ROOF CAP ROUND ELBOW 6 ROUND DUCT WALL CAP DECORATIVE FLUE HOOD MOUNTING BRACKET The minimum hood distance above cooktop MUST NOT BE less than 26. HOOD A maximum of 30 above cooktop is highly recommended for best capture of cooking impurities. For a gas range, the bottom of the hood MUST NOT BE LESS than 30 above cooking surface. 3¼ 12 5 /8 TO CENTER OF BRACKET HOLES NOTE: For a 9 feet high ceiling, the bottom of the hood MUST BE located at least at 30 above a 36-inch high cooktop. Distances over 30 are at the installer and users discretion; providing that ceiling height permit. 26 MINIMUM ABOVE COOKING SURFACE (30 FOR GAS RANGE) HH0097A -3-

3. PREPARE INSTALLATION NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer. Make sure that the following items are included: 1 - Hood 1 - Decorative Flue Assembly (lower and upper flues) 1 - Lower Flue Mounting Bracket 1 - Hood Mounting Bracket 1 - Upper Flue Mounting Bracket 1 - Parts Bag containing: 8 - No. 8 x 7/16 Mounting Screws 7 - No. 8 x 1½ Mounting Screws 9 - Drywall Anchors 2 - Washers 2 - No. 8 x 1¼ Mounting Screws 4 - Aesthetic Washers 4 - M4 x 0.7 Mechanical Flat Head Screws NOTE: If need be, discard extra screws. 2 - Aluminum Grease Filters 1-6 Round Adapter/Damper 4. WIRING INSTALLATION DECORATIVE FLUE UPPER FLUE MOUNTING BRACKET HR0031A 1 - Curved glass (VJ603302SS only) or stainless steel plate (VJ604302SS only) 1 - Installation Manual 6 ROUND ADAPTER/DAMPER LOWER FLUE MOUNTING BRACKET HOOD MOUNTING BRACKET Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. This range hood must be properly grounded. Turn off electrical power at service entrance before wiring. GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance. Set the electrical power supply within the space covered by the decorative flue. Position the outlet offset so that the power cord will not interfere with the round duct. Place the outlet at a maximum distance of 33 7 /16 from where the cord exits from the hood (see illustration alongside). Make sure this does not interfere with a mounting bracket fastening area or with the decorative flue (where the flue touches the wall). 33 7 16 MAX. -4- HE0086

5. INSTALL HOOD MOUNTING BRACKET Make sure power is switched off at service panel before starting installation. WALL STUDS FRAMING BEHIND DRYWALL When cutting or drilling into wall, do not damage electrical wiring and other hidden utilities. 1. Construct wood wall framing that is flush with surface of wall studs. Make sure: a) the framing is centered over installation location b) the height of the framing will allow the mounting bracket to be secured to the framing within the dimensions shown. 2. After wall surface is finished, carefully center and level the hood mounting bracket, secure it to wall framing with 3 no. 8 x 1½ mounting screws. Tight the screws completely. HD0254A 38 5/8 = BOTTOM OF HOOD 26 ABOVE COOKTOP 42 5/8 = BOTTOM OF HOOD 30 ABOVE COOKTOP 6. INSTALL UPPER FLUE MOUNTING BRACKET Center the bracket over the hood location and place it flush with the ceiling. Make sure that the slots of the upper flue bracket point down. Use the upper flue mounting bracket as a template to mark the position of its screws. Drill both screw holes using a 5/16 drill bit. Insert the included drywall anchors into the drilled holes (one per hole). Secure the upper flue bracket to the wall using 2 no. 8 x 1½ mounting screws. Make sure that the bracket is tight against the wall. CEILING CENTER OF INSTALLATION UPPER FLUE MOUNTING BRACKET SLOTS HD0247 C L MOUNTING BRACKET FLUSH WITH CEILING -5-

7. INSTALL HOOD BE CAREFUL when installing the decorative flue and hood, they may have sharp edges. CAUTION DO NOT REMOVE the protective plastic film covering the decorative flue (upper and lower) and the hood yet. 1. Lay the back side of the hood flat on a table. Use a piece of cardboard to avoid Fig. 1 damaging the table or the hood. 2. Remove the grease filters by pulling down the metal latch tab and tilting filters downward to remove. 3. Align the hood and center it above the hood mounting bracket. Gently lower the hood until it securely engages the bracket. 4. With the hood hanging in place, drill through both holes located in the inside lower back of hood (Fig. 1) using a 5/16 drill bit. Insert the included drywall anchors into the drilled holes (one for each hole). Insert 2 no. 8 x 1¼ mounting screws in 2 washers (one per washer), then insert into the drywall anchors. Verify that the hood is centered and leveled. Tighten all screws completely. 5. Reinstall grease filters by aligning rear filter tabs with slots in the hood. Pull down the metal latch tab, push filter into position and release. Make sure filters are securely engaged after installation. HD0255A 6. Install 6 round adapter/damper on top of the hood using 4 no. 8 x 7/16 mounting screws. 7. Remove protective plastic film covering the lower flue only. 8. Install the lower flue bracket to its flue using 2 no. 8 x 7/16 mounting screws, make Fig. 2 sure that the slots point up (Fig. 2). 9. Carefully place both flues into the recessed area of hood top. Slightly slide up the upper flue to avoid any damage while placing the lower flue to the hood top. 10. Slide a 6 metal round duct over the adapter/damper (Fig. 3). Use metal foil duct tape to seal the joint. 11. Plug hood power cord into the outlet. 12. Slide up the upper flue until it is aligned with its mounting bracket. The bracket should be inside the flue. Secure the upper flue to its bracket using 2 no. 8 x 7/16 mounting screws (Fig. 4). 13. Remove protective plastic film covering the upper flue and the hood. 14. Mount the glass plate or the stainless steel plate on the top of hood base with 4 mechanical flat head screws (M4 x 0.7 ) and 4 aesthetic washers. Screw from top of hood base. SIDE VIEW LOWER FLUE HO0114 INSIDE BACK OF THE HOOD 14¼ HOLES LOCATION MOTOR/BLOWER ASSEMBLY Ø 5/16 TYP. LOWER FLUE MOUNTING BRACKET BACK VIEW SLOTS UP Fig. 3 Fig. 4 UPPER FLUE MOUNTING BRACKET FRONT VIEW 6 ROUND DUCT UPPER FLUE HO0104 HJ0012A -6-

8. GREASE FILTERS 1. To remove the grease filters, pull down on the metal latch tab and tilt each filter downward to remove. 2. To install the grease filters, align rear filter tabs with slots in the hood. Pull down the metal latch tab, push each filter into position and release. Make sure filters are securely engaged after installation. HD0256 9. LIGHT BULBS Always switch off the electrical supply before carrying out any operation on the appliance. This range hood requires two UL approved halogen bulbs (Type JC, 12 V, 20 W Maximum, G-4 Base). In order to prevent the risk of personal injury, the halogen lamps must be cooled down before removing them. LIGHT BULB COVER To change bulbs: 1. Gently push the rim upward and turn counterclockwise to disengage the light bulb cover. HD0257 CAUTION Do not touch replacement bulb with bare hands! 2. Replace with Type JC, 12V, 20 W Maximum, G-4 Base halogen bulb. 3. Replace the light bulb cover by pushing the rim upward and rotating the light bulb cover clockwise. 10.OPERATION 1 HC0048 Lamp Speed Timer Power 2 3 4 1) Time/Delay push button 3) Blower push button 2) Lighting push button 4) ON/OFF push button The hood is operated using the push buttons located on the front panel. -7-

10.OPERATION (continued) 1. TIME/DELAY (2 Functions): - Time Setting: This button is used to set time when lighting and blower are not in use. Time is displayed in 24 hour cycle. To set time, press the push button (1) for 3 seconds. The first two digits will flash. Use the blower push button (3) to increase and the lighting push button (2) to decrease. Press the time/delay push button (1) again, the last two digits will flash. Use the blower push button (3) to increase and the lighting push button (2) to decrease. Press the time/delay button (1) again to confirm and exit time setting mode. - Delay Setting: When blower is in use, this button is the delay setting button. To set delay, press the push button (1). The delay is factory set at 5 minutes, but can be set from 1 up to 60 minutes. Use blower push button (3) to increase and lighting push button (2) to decrease. Countdown will be displayed on the LCD screen and blower symbol will be activated. Blower will continue to operate for the programmed minutes and then will stop automatically (delay setting mode does not affect lighting as it works independently). The last time used will be memorized. To cancel delay function, press time/delay push button (1) again, the blower will continue to operate and won t stop until ON/OFF push button (4) is pressed. To turn delay function and blower OFF at once, press ON/OFF push button (4). NOTE: Delay will be reset if blower speed is modified during delay setting mode. 2. LIGHTING: Pressing the lighting push button (2) once will turn the LCD screen on. To turn the lights on, press the lighting push button (2) once more. Press it again to turn the lights OFF. The LCD screen will turn automatically off after 15 seconds of inactivity (blower and/or lights). 3. BLOWER: The blower push button (3) turns the blower on to three speed settings: LOW, MEDIUM or HIGH. Press the blower (3) or ON/OFF (4) push button once to turn the LCD screen on. Pressing the blower (3) or ON/OFF (4) push button once more will turn the blower on at the last selected speed and blower symbol will be activated. To change the blower speed, press the blower push button (3) until the desired speed is obtained. Press the ON/OFF push button (4) to turn the blower OFF. The last speed used will be memorized. NOTE: When blower is turned on, 100% of power level is activated during 1 to 2 seconds acting as a kick-start. It will then operate at the previous setting. 11.CARE Before servicing or cleaning the unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Grease Filters Grease filters should be cleaned monthly. Remove grease filters by pulling down on the metal latch tab. This will disengage the filter from the hood. Tilt the filter downward and remove. Use a warm detergent solution to clean the filters. Let them dry and reinstall them. Grease filters are dishwasher safe. Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filters may occur if using phosphate detergent or as a result of local water conditions but this will not affect filters performance. This discoloration is not covered by the warranty. Hood Cleaning Stainless Steel Cleaning: How to maintain its BRIGHT LOOK and help prevent corrosion. Dos: - Regularly wash surfaces with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent. - Always clean in the direction of original polish lines. - Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely. - You may also use a specialized household stainless steel cleaner. Don ts: - Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt. - Use any harsh or abrasive cleansers. - Allow dirt to accumulate. - Let plaster dust or any other construction residues reach the hood. During construction or renovation, cover the hood to make sure no dust sticks to stainless steel surface. Avoid when choosing a detergent: - Any cleaners that contain bleach will attack stainless steel. - Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly. - Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should never be used close to a range. Curved Glass Plate Cleaning: Hot water with mild soap or glass cleaner is all that is usually needed. When using mild soap, rinse with clear water. Wipe dry with a clean, soft cloth to avoid water marks. -8-

12.REPLACEMENT PARTS 1 7 6 REPLACEMENT PARTS AND REPAIRS: In order to ensure your ventilation unit remains in good working condition, you must use Venmar Ventilation Inc. genuine replacement parts only. Venmar Ventilation Inc. genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing. Venmar Ventilation Inc. also recommends to contact a Venmar certified service depot for all replacement parts and repairs. HL0128 2 3 4 3 5 KEY NO. PART NO. DESCRIPTION QUANTITY 1 07250 Decorative upper and lower flues 1 2 07243 Motor and Blower assembly 1 3 07244 Light assembly (set of 2) 1 4 09071 LCD Control interface 1 5 07759 Aluminum grease filters (set of 2) 1 6 09072 Transformer for LCD Control interface 1 7 07251 30 Curved glass plate 1 * 09074 36 Curved glass plate 1 * 07252 Curved stainless steel plate with rail 1 * 08486 Bracket kit (set of 3) 1 * 09073 PC Board and plastic enclosure 1 * SV20601 Halogen bulbs JC type, 12 V, 20 W, G4 base (set of 2) 1 * 07241 Parts bag including: 8 no. 8 x 7/16 mounting screws, 7 no. 8 x 1½ mounting screws, 9 drywall anchors, 2 washers, 2 no. 8 x 1¼ mounting screws, 4 aesthetic washers, 4 M4 x 0.7 mechanical flat head screws. 1 *Not illustrated. -9-

WARRANTY VENMAR JAZZ RANGE HOOD 1-YEAR LIMITED WARRANTY Venmar Ventilation Inc. warrants to the original consumer purchaser of its products, that such products will be free from defects in materials or workmanship for a period of one (1) year from date of original purchase. This warranty includes in-home service. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. VENMAR VENTILATION INC. WILL NOT BE HELD RESPONSIBLE FOR ANY CLAIMS OVER THE ORIGINAL PURCHASE PRICE OF A VENMAR JAZZ RANGE HOOD, NOR HELD RESPONSIBLE FOR SUBSEQUENT DAMAGE OR INCIDENT. During this one-year period, Venmar Ventilation Inc. will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO BULBS, FUSE, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover a) normal maintenance and service b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repairs made by other than Venmar Ventilation Inc., or c) a faulty installation or installation contrary to recommended installation instructions. Warranty service is to be completed by an authorized Service Center designated by Venmar Ventilation Inc. Where applicable, in-home service will be made available only in areas where a contracted service provider offers service. If in-home service is not available, the product will be repaired or replaced, at Venmar Ventilation Inc. s discretion, by the nearest authorized service provider. The unit removal and reinstallation works are under the customer responsibility, and Venmar Ventilation Inc. cannot be charged for them. The duration of any implied warranty is limited to the 1-year period as specified for the express warranty. Some provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. VENMAR VENTILATION INC. OBLIGATION TO REPAIR OR REPLACE AT VENMAR VENTILATION INC. OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. VENMAR VENTILATION INC. SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. SOME PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. This warranty gives you specific legal rights and you may also have other rights, which vary from one province to another. This warranty supersedes all prior warranties. To contact Venmar Ventilation Inc. Warranty Service call 1-800-567-3855 (in Canada). In order to qualify for a warranty claim, the owner of a Venmar Jazz range hood must have the model and serial number along with a proof of the original purchase date. At the time of requesting service, describe the nature of any defect in the product or part. Venmar Ventilation Inc., 550 Lemire Blvd., Drummondville, Quebec CANADA J2C 7W9 Tel.: 1-800-567-3855 Fax: 819-475-2660 www.venmar.ca -10-