mith Mills 4500A Smith Mills 4500A 4500A-3R OIL, GAS OR COMBINATION GAS/OIL COMMERCIAL BOILER/BURNER CAST IRON

Similar documents
mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON

mith Mills 3500A Smith Mills 3500A 3500A-3 OIL, GAS OR COMBINATION GAS/LIGHT OIL COMMERCIAL BOILER/BURNER CAST IRON

SERIES 19A. mith PRESSURIZED WET BASE

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

650A/6500A MILLS BOILER

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Proven Heritage RTS STANDARD EQUIPMENT. (413) FAX: (413) You can rely on Smith Cast Iron

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

G315/5 Cast Iron Boiler

G315/6 Cast Iron Boiler

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

Replacement parts EG/PEG

G515/7 Cast Iron Boiler

G615/11 Cast Iron Boiler

SECTION HEATING BOILERS

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

SECTION WATER-TUBE BOILERS

JE Series Cast Iron Commercial Natural Gas Steam Boiler Submittal/Specifications

Peerless Boilers. Series MI. Residential Gas Boilers

Section B1. Flexible Watertube Boilers TABLE OF CONTENTS

FXLF-9. High Efficiency Water Heaters and Boilers

Columbia Boiler Company

Series 300 VTB. Installation Instructions

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

MX 200. MX-200 Technical Specifications FEATURES:

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS

Series 8H. Cast Iron Gas Fired Commercial Water Boiler

Williams & Davis Boilers

Unmatched high efficiency product selection

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

MX 200. MX-200 Technical Specifications FEATURES:

Boiler & Water Heater

JD Series Cast Iron Commercial Hot Water or Steam Boiler

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

Counterflo CF BASIC COUNTERFLO HEATER RCF CURB MOUNTED ROOFTOP HEATER CFDF COUNTERFLO DUCT FURNACE INDIRECT-FIRED INDUSTRIAL HEATERS

Williams & Davis Boilers

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Quantity X Section Assembly (Intermittent and Continuous Circulation Only)

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

Series. Gas/Oil Boilers Water. Oil, Gas & Installation, Operation & Maintenance Manual

.2 Section Waste Management and Disposal..4 Section Vibration Isolation and Seismic Control Measures.

ECLIPSE INFORMATION GUIDE

GB Condensing Gas Boiler

DOM-5. Domestic Hot Water Heaters & Boilers

GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.

CSD-1 COMMERCIAL BOILER CONTROLS

SAMPLE SPECIFICATIONS

COMMERCIAL HYDRONIC HEAT PRESSURE FIRED, WET BASE, OIL, GAS OR COMBINATION. Heating Capacities 667 to 4551 MBH Output V11 SERIES

FTIIIC-10. Domestic Hot Water Heaters and Boilers

Domestic Hot Water Heaters and Boilers FTIIIC-6

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

GB Condensing Gas Boiler

BUDERUS. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. BUDERUS. G Cast Iron Commercial Boilers

Rental Boiler Specifications (Nebraska Boiler)

ALDRICH COMPANY THREE PASS FIRETUBE BOILER CLASSIC SERIES OPERATING & MAINTENANCE MANUAL

High efficiency, cast-iron gas boiler

MODEL CEW OHIO SPECIAL

SERVICE TECHNICIAN ONLY read and follow completely.

PB HEAT, LLC TRADE PRICE LIST EFFECTIVE JUNE 1, 2018 P-18

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

Series EC/ECT Residential - Packaged or Knockdown Natural Draft Venting Flame Retention Burner Steam or Hot Water Boilers Optional Tankless Coils

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY.

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

PACKAGED COMMERCIAL WATERTUBE BOILERS

Standard Equipment: Water. 30 PSI Safety Relief Valve Temperature-Pressure Gage BOILER RATINGS. Series WBV. Steam, MBH 3

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Design and Construction Standards SECTION PLUMBING EQUIPMENT

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications

Suggested Specifications Prestige Excellence 110

SECTION PLUMBING EQUIPMENT

Copyright 2009 Power Flame Incorporated

FXLF-4. High Efficiency Water Heaters and Boilers

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Burner Comparisons. Typical Competitor s Burner

DIVISION FINNED WATER-TUBE WATER HEATERS

Boiler Manual. Oil-Fired Steam Boilers. Maintenance Parts. Installation Startup

HHA Lyerly Apartments 75 Lyerly Houston, Texas J. Allen Management Managing Agent

Pump or Manifold Pressure. Nozzle or Gas Orifice Size. Air Setting

DIVISION FINNED WATER-TUBE BOILERS

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

ADF/ADFH 300 and 500

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Transcription:

Mills 00A mith Mills 00A Smith CAST IRON OIL, GAS OR COMBITION GAS/OIL COMMERCIAL BOILER/BURNER 00AR

STEAM GAUGE OPERATING CONTROL MODULATING CONTROL HI LIMIT PRESSURE CONTROL 0" STEAM DRUM TEST COCK /" TEE " x /" NIPPLE /" SIPHON " HYDRONIC CROSS " PLUG " x " LOCKNUT NIPPLE " x " NIPPLE WATER LINE No. 7RLS PUMP CONTROL AND LOW WATER CUTOFF " x /" NIPPLE FRONT VIEW WITH INDUST. COMB.BURNER STEAM BOILER S M " HYDRONIC CROSS " BALL VALVE 9 /" TO GROUND FRONT VIEW WITH STEAM TRIM FRONT VIEW POWERFLAME OR WEBSTER " " WATER SUPPLY DRUM JACKET 7" " PLUG FOR DRAFT SAMPLE TUBE JACKET WATER LINE /" 8 /" 9 " 9 /" 7/8" 7" 9 " 8 /" CLEAN OUT COVERS 8" x 8" ACCESS OPENING AND COVER " " " 8" " " " 88 /" STEAM 8 /" WATER 9 /" C L BURNER " " CAP 9 /" 7" " " DRAIN /" " DRAIN 8" /" " 8" FRONT VIEW WITH PREF. UTIL. BURNER WATER TRIM RETURN 7/8" FOUNDATION BACK YOKE 0 /" " TURAL DRAFT WATER " " /" " " " /" INTERMEDIATE SECTION I=B=R Ratings, Capacities, and Chimney Data BOILER MODEL NUMBER Horsepower I = B= R Gross Output () Sq. Ft. NET I= B=R RATINGS Steam (Note ) Water (Note ) I=B=R Capacity GPH (Note ) Gas I=B=R Combustion Efficiency (%) Gas Requirements (Inches, W.C.) Over Fire Loss Total Natural Chimney Size Height (Feet) Outlet Adapters Nat. N O P Induced Fan Capacity CFM (Auburn Axial & Auburn) (Note 7) 00A 0 00A 00A 00A 00A 00A 00A 00A 7 00A 8 00A 9 00A 0 00A 00A 9.0 0...7 8. 9.8. 7.9 8. 9.0 07. 9. 0. 080 7 8 0 7 0 00 787 7 0 97 7 770 99 7 77 97 77 87 997 7 7 97 9 9 99 9 9 89 9 9 79 09 9 9 99 78 0 0 87 0 0 9 0 9 70 0 77 7 7.0 0..0 7.0 0..0 7..0.0 7.0.0.0 7.0 90 0 888 7 8 8 709 779 877 87 9 970 8. 8. 8. 8.9 8.8 8.7 8. 8. 8. 8. 8. 8. 8. 8. 8.8 8. 8. 8. 8. 8.0 80.9 80.9 80.8 80.7 80.7 80..0.0.0.0.0.0.0.0.0.0.0.0.0.8...0..8...0..8..7.8...0..8...0..8.7.77 0x x x x8 x8 x8 8x8 8x8 8x8 0x0 0x0 0x 0x 7 7 8 9 98 0 0 9 9 9 9 9 9 0 8 97 9 78 878 08 7 Insert "LO" for Light, "G" for Gas, "GLO" for GasLight Combination, GHO for GasHeavy Combination. Insert "S" for Steam, "W" for Water. Example: HO00AS0 is a 0 section Mills boiler for steam, using heavy oil. Note Net I=B=R Steam ratings shown are based on piping and pickup allowances of.88 Note Net I=B=R Water Ratings shown are based on an allowance of.. Note Light having a heat content of 0,000 Btu/Gal.

MILLS 00A BOILERBURNER UNIT T L F E D FRONT PED C UP TO " ON B ORDER # # # A /" S() # " /" /8" /8" 0" DIA. NO SHELF ON AND SECTIONS WATER SUPPLY DRUM # " " " PIPE /" PIPE /" x /" TEE PLAN VIEW " x /" ELL SEAL AROUND PIPE WITH FURCE CEMENT FLOOR W S 7 /" TOP VERTICAL DISCHARGE Clockwise Rotation View from back of boiler (Opposite hand from view above for counter clockwise rotation) OPTIOL DISCHARGE POSI TIONS AUBURN FAN WITH INDUST. COMBUSTION BURNER WEBSTER BURNER P/F BURNER / / /8 / / 0 / FRONT VIEW L G F E D A B C TYP. / BOSS, BOTH SIDES / BOSS, BOTH SIDES ( OPTIOL, ONLY) LEFT SIDE ONLY LOCKNUT THREAD FRONT OF DRUM 0" X " OVAL STEAM SUPPLY DRUM PITCH UPWARDS AUXILIARY FLUE GAS VENT FOR GAS FIRED BOILERS Dimensions in Inches No. J L M S T W EE 00A0 /8 0 7/8 7 00A / / 7 8 /8 8 TURAL DRAFTWATER WITH PREF. UTIL. BURNER AUBURN AXIAL FAN AUBURN AXIAL FAN AUBURN FANSTEAM AUBURN FAN Designed and tested according to the A.S.M.E. boiler and pressure vessel code. Section IV for maximum allowable working pressure. Steam lbs. Water 0 lbs.for 80 psi working pressure consult Smith. Induced Fan Catalog Number (Note ) Auburn Axial Fan to Fit Smokehood B7 B00 B00 B0 B0 B00 B00 B00 Auburn Fan and Smokehood to Fit B0 B7 B7 B7 8B.0 8B.0 8B.0 8B. 8B. 8B.0 8B.0 8B.0 8B.0 Induced Chimney, Inside Dimensions Round (I.D.) 70 8 9 9 0 7 8 8 9 Metal Flue Pipe or Smooth Lined Masonry (In.) Rectangular Minimum Optimum x 7x 7x7 8x7 9x8 9x9 0x9 x9 x9 x0 x x x 8x8 9x9 0x0 x0 x x x x x x 8x 8x 0x Heating Surface (Sq. Ft.).. 97.0 0. 8.9. 8.7 7.0 7. 797. 89.8 88. 9. Note The induced draft fan selections listed are based on a chimney capable of offsetting the friction in the fan discharge connection. Note Including combustion chamber. For other conditions, consult your Smith representative. Note 7 Light figures shown based on multiplier of. CFM/GPH. For Heavy, use a multiplier of 0x firing rate. For natural gas firing use a multiplier of.7 CFM/ input. Furnace Volume (Cu. Ft.) (Note )..87 7..8 9. 7.89 80. 8. 9.7 97.9 0.8 09..9 Water Content (Gallons) Steam 9 7 88 0 7 0 79 9 0 Water 8 0 7 8 88 08 9 9 9 Furnace Lgth. (In.) Foundation Lgth. (In.) Tapping Size Water Supply Drum Tapping Location B C A B C D E F L 0 7 78 8 90 9 0 08 0 0 7 78 8 90 9 0 08 0 0 8 0 0 8 8 0 I=B=R Ratings: Gross Output,080 to 7,70 8 0 0 8 8 7 7 80 80 9 7 77 80 8 9 97 0 7 80 8 9 98 0 09 8 7 80 89 9 0 07 8 9 7 77 8 89 9 0 07 9 Tapping Size Steam Supply Drum Tapping Location A B C D E F G L Dimensions, Electrical Requirements 00A 8 8 8 8 8 0 8 0 7 7 79 8 79 8 9 97 7 7 79 8 9 97 0 09 7 9 D D D D D D D8 D8 D8 D8 D8 D0 D0 I.C.Electrical Requirements Perf. Electrical Requirements Power Flame Webster Electrical Requirements Horsepower (kw) Horsepower (kw) Elect. Require. Horsepower (kw) Blower 7 7 Metering Pump Air Comp. Aux. Heater X* X*9 X* X* X*8 X* X* X*7 X*0 X* X* X*9 X* Second. Air Fan Aux. Heater C C C C C C C C C C C C C Net H.P. JB JB0 JB0 JB0 JB0 JB0 JB0 JB0 JB0 JB0 JB7 JB7 JB7 The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping, etc. With modern fast steaming boilers, careful consideration of the provisions for makeup water must be given to insure successful operation. Consult factory representative for details. / H.P. for remote pump set for oil and gas/oil burners only. * Insert H for Heavy oil. Example: XH ** Compressor motor and oil heater used for, or oil units only. Note: Dimensions are approximate and should not be used to roughin equipment. Blower..0.0.0.0.0.0.0.0.0 7. 7. 7. Pump ** Comp. ** Auburn Heater Axial Induced Fan (HP) Auburn

STANDARD EQUIPMENT 00A Mills headertype cast iron sectional boiler Foundation front plate, with observation ports, ready to receive burner. Insulated metal jacket. Choice of Preferred Utilities Injectaire, Industrial Combustion D or Webster JB forced draft burners for all grades of fuel oil, gas or combination gas/ oil, or Powerflame C pressure atomizing burners for light oil, gas or combination gas/light oil. Water s 80 psi working pressure Manual reset high limit temperature control. Operating temperature control. Firing rate control. Pressure altitude gauge. / remote reading dialthermometer. A.S.M.E. relief valve set at 0 psi. Dip tube, air removal fittings and manual vent valve. Low water cutoff with precut ferrous pipe and necessary fittings. Precast combustion chamber, precut block insulation, vent tile, and refractory pellets. Flexible return yoke. Two / brass balltype drain valves. Programmingtype flame safeguard control,motor starters, low fire start relay (oil) service switch, two pilot lights (power and main fuel), and terminal strip for easy field wiring. Control panel location and type varies with burner selected and components chosen. Steam s Manual reset high limit pressure control. Operating pressure control. Firing rate control. Pipe tree with syphon for controls. Pressure gauge with syphon (0 psi). A.S.M.E. side outlet safety valve ( psi). Combination water columntype pump controller and low water cutoff with precut ferrous piping and necessary fittings. OPTIOL EQUIPMENT Induced Fans Auburn or Auburn Axial. Shutter dampers for sequence draft control. Field Barometric draft control. Comply with insurance code requirements, F.M., I.R.I., etc.,state and utility codes. (See back page for details.) Alarm bell ( ) with silencing button and relay. Cabinet latch with lock and key. Control transformer. Additional alarm relays.. Flame failure.. Low water. High pressure.. High temperature.. Excess smoke (with test switch). Protruding circuit breakers. Lead/lag for up to boiler operation. Automatic fuel changeover (Gas/). Second solenoid oil valve. Water s A.S.M.E. relief valve with other than 0 psi setting. Low water cutoff for over 0 Lbs. operation. Low water cutoff with line voltage alarm switch. Low water cutoff with manual reset. tapping in supply header with flange for tankless heater Flow switch. Steam s Combination low water cutoff and feeder. Cast iron water column in lieu of combination water columntype pump controller and low water cutoff. High water level cutoff with precut pipe and fittings. 8 pressure gauge. 8 compound gauge.

THESE FEATURES ASSURE TOP PERFORMANCE Scientifically Matched Unit Every detail of the 00A unit for oil and gas is the result of years of research and development. The boiler, the burner, the draft system, the control system, and the combustion chamber are completely compatible. The 00A offers a choice of four burners from top manufactures, each tailored for maximum efficiency and tested and listed by I.B.R. Single source responsibility can be assured, whether your fuel choice be # thru # oil or gas. Each unit is backed by factory service technicians from a factory service force formed in 90. A wide variety of control panel options, draft systems and I.D. fans can be tailored for most any need, no other cast iron boiler company can offer you all these features. Header Type Construction Standard Electrical Characteristics s phase, 08 volt, 0 Hz; phase, 0 volt, 0 Hz; phase,0 volt, 0 Hz. Control Circuit phase, volt, 0 Hz Heater (when used) phase, 0 volt, 0 Hz. Mills boilers are independent header type sectional boilers. Each section is, in reality, an individual boiler connected to supply and return headers. Should some accident, such as low water, cause a section to break, it may be disconnected in a few minutes time without interruption of service and may be replaced when convenient. I.C. MODEL D # #, Gas, or Combination POWERFLAME MODEL C #, Gas, or Combination In the interest of product improvement, Smith reserves the right to make changes without notice. Smith CAST IRON Westcast, Inc. 0 North Elm Street Westfield, MA 008 Tel: () 9 FAX () 799 www.smithboiler.com Printed in U.S.A.