BSR/ASHRAE Addendum b to ANSI/ASHRAE Standard FORWORD

Similar documents
Safety Standard for Refrigeration Systems

1. PURPOSE This standard specifies safe design, construction, installation, and operation of refrigeration systems.

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement


First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

ICC CODE CORNER 2015 International Fire Code

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

First Revision No. 20-NFPA [ Section No ]

Ammonia Refrigeration RAGAGEP

CHAPTER 17 STANDARDS STANDARDS Broadway, New York, NY 10018,

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ]

ARTICLE 25. FUEL GAS CODE

GASEOUS HYDROGEN SYSTEMS

RAGAGEP: Codes, Standards, and Good Engineering Practice PETER THOMAS, P.E. PRESIDENT AND ENGINEER RESOURCE COMPLIANCE

Second Revision No. 3-NFPA [ Section No. 2.3 ]

CHAPTER 45 REFERENCED STANDARDS

CHAPTER 5 REFERENCED STANDARDS. American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Change all instances of "flame resistant (hypobaric)" to "Limited-Combustible (material)" in all instances in the document.

ACKNOWLEDGEMENT. IIAR expresses its deepest appreciation to these authors for their contributions for the betterment of the industry.

CHAPTER 15 REFERENCED STANDARDS SECTION MC 1502 STANDARDS. Number Title section number Manual D 95 Residential Duct Systems

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

CHAPTER 6 [CE] REFERENCED STANDARDS

ASHRAE WILL GIVE YOU THE WORLD

Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference

Flammable Liquid: A liquid whose flashpoint is greaterless than 100 F when tested by closed-cup test methods.

CHAPTER 6 REFERENCED STANDARDS. American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL

Ammonia Refrigeration RAGAGEP

RAGAGEP UPDATE. Douglas Reindl, Director, IRC 2016 IRC R&T Forum

Providing Solutions. Simplifying Regulation. IIAR Standards. Peter Thomas, P.E., CSP Resource Compliance, Inc.

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

REFRIGERATION CHAPTER 11

SECTION (15530) - REFRIGERANT PIPING

The Electronic Newsletter of The Industrial Refrigeration Consortium Vol. 11 No. 1, 2011

Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

Above Ground Fuel Tank Requirements

Understanding Recognized and Generally Accepted Good Engineering Practices (RAGAGEP) for the Ammonia Industry

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

REFRIGERATION CHAPTER 11

Specifications for Refrigerants

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

analysis ASHRAE : Implications for Mechanical Room Design

CARBON DIOXIDE SYSTEMS FOR BEVERAGE DISPENSING PERMIT REQUIREMENTS

Ammonia Refrigeration RAGAGEP

BETACURE 100 CO-REACTANT

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

Update on ASHRAE 15 Safety Standard for Refrigeration Systems Karim Amrane Air Conditioning, Heating & Refrigeration Institute (AHRI)

CUMULATIVE ANALYSIS OF UNIFORM MECHANICAL CODE CHANGES to 2003

CHAPTER 45 REFERENCED STANDARDS

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

SECTION (15530) - REFRIGERANT PIPING

Committee on NFPA 51A

Report on First Revision November 2013 NFPA 750

Specifications for Fluorocarbon Refrigerants

Standard Compared 2012 Changes of the International Building Code and National Fire Protection Association- 101

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

REFRIGERATION CHAPTER 11

A NATIONAL SET OF HYDROGEN CODES AND STANDARDS FOR THE US

REFRIGERATION CHAPTER 11

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

4/18/2017. *2012 edition of NFPA 99 has gone through a major overhaul. *This document is now a Code.

Description of the European standard EN 378: Refrigerating systems and heat pumps Safety and environmental requirements

Specifications for Fluorocarbon Refrigerants

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

6/9/ :58 PM. First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2000 EDITION

Page 1 of Relevant Provincial Jurisdictional legislation.

Performance Rating of Refrigerant Pressure Regulating Valves

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

CHAPTER 15 REFERENCED STANDARDS

CHAPTER 11 REFRIGERATION

National Fire Protection Association M E M O R A N D U M. NFPA Technical Committee on Construction and Demolition

Air Moving Systems. Fire Safety Inspection and Testing of. NBSIR jan «1933. Washington, DC General Services Administration

Specifications for Refrigerants

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X

CHAPTER 45 REFERENCED STANDARDS. number Title section number HB Specification for Highway Bridges, 17th Edition

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

Understanding. Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations

NFPA 96, 2017 REVIEW SUMMARY

First Revision No. 22-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

This standard applies to new installations and to those portions of existing equipment and installations that are modified

SEMICONDUCTOR FABRICATION FACILITIES

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

First Revision No. 1-NFPA 30A-2015 [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

1 Exam Prep Florida Building Code-Mechanical Tabs and Highlights

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

Meeting NFPA standards for

AHRI Guideline N Guideline for Assignment of Refrigerant Container Colors. ARI Standard 1200

Hot Surface Ignition Testing of Low GWP 2L Refrigerants

CHAPTER 15 REFERENCED STANDARDS. Air-Conditioning, Heating and Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

First Revision No. 1-NFPA [ Chapter 2 ]

MEMORANDUM. NFPA 51 First Draft Technical Committee FINAL Ballot Results (A2017 Cycle)

R-407A R-448A R-449A

Transcription:

(This foreword is for information only and is not part of this addendum) FORWORD Changes in this addendum to ANSI/ASHRAE 15-1994 are made to add water as a refrigerant, include absorption refrigeration machines in the standard and clarification of wording in selected sections as a result of Continuous Maintenance submissions. This addendum eliminates several of the unnecessary references (informative and normative). When reviewing this addendum it is important that the reviewer have access to approved addenda 15a, 15c and 15d to ASHRAE 15-1994 (available on ASHRAE web page at www.ashrae.org). The changes in this addendum include: Change in the title and scope to include absorption refrigeration machines and water as a refrigerant. Two new definitions in Section 3 and changes to 4 existing definitions. Change in the title of Table 2. revise the wording of 8.3 and delete 8.4 and 8.6. Addition of Exception (b) to 8.13.2.1, Exception (1) in 8.13.6, an the addition of an Exception in 8.16. Add a maximum temperature to 8.13.5(b). Clarification of the refrigerant detector wording in 8.13.6 and 8.14. Adding the requirement for refrigerating equipment to be designed for a vacuum and a design pressure for absorption machines in 9.2.1. Adding requirements to 9.5.1 for relief valves discharging into other parts of the system Clarification of the wording in 9.12.1 and 9.12.3 along with the deletion of 9.12.2. Adding 9.14.1.1 Test Procedure for factory tests. Adding 9.13 Listed Equipment to section 9 to replace 2.4 deleted from the Scope. Adding R-718 (water) to Table 1. Delete unnecessary references in Appendix D. Delete unnecessary references in Appendix E. Note to reviewers: Portions deleted are shown with a line through the text; added text is underlined. 1

Title: Safety CodeStandard for Mechanical Refrigeration Systems 1. PURPOSE The purpose of thisthis standard is to specifyspecifies safe design, construction, installation, and operation of refrigeratingrefrigeration systems. 2. SCOPE 2.1 This codestandard establishes safeguards for life, limb, health, and property, and prescribes safety standardsrequirements. 2.2 This codestandard applies (a) to the design, construction, test, installation, operation and inspection of mechanical and absorption refrigerationing systems including and heat pump systems used in stationary applications, the occupancies defined in Section 4 and installed subsequently to adoption of this code; and (b) to modifications including replacement of parts or components if they are not identical in function and capacity,added after adoption of this code, or a change to a refrigerant of a different number designation (per ANSI/ASHRAE Standard 34-1992 4 ) after adoption of this code; and (c) to substitutions of refrigerant having a different designationparts or components replaced after adoption of this code only if they are not identical in function. 2.3 This code does not apply where water is the primary refrigerant. 2.4 Equipment listed by an approved, nationally recognized testing laboratory is deemed to meet the design, manufacture, and factory test requirements section of this code for the refrigerant or refrigerants for which the equipment was designed. 2.5 The authority having jurisdiction has the authority to grant exceptions from the requirements of this code or allow, for local jurisdictional purposes, the use of other devices, materials, or methods when evidence is provided to demonstrate equivalent protection and performance. 3 DEFINITIONS: accessible: easy to approach for service or use (also see readily accessible). readily accessible: capable of being reached safely and quickly for operation, repair and inspection without requiring those to whom ready access is required to climb over or remove obstacles or to resort to the use of portable access equipment. refrigerant detector: a device that is capable of sensing the presence of refrigerant vapor. sealed ammonia/water absorption system: an absorption system where ammonia (R-717) is the refrigerant and water is the absorbent and all refrigerantcontaining parts are made permanently tight by welding or brazing. 2

Lithium Bromide/water absorption system: an absorption system where water (R- 718) is the refrigerant and lithium bromide (LiBr) is the absorbent. secondary coolant: any liquid used for the transmission of heat, without a change of state vaporization., and having no flash point or a flash point above 150 F (65.5 C) as determined by the ASTM D93. 2 TABLE 2 Special Quantity Limits for Sealed Ammonia/Water Absorption and Self-Contained Systems Maximum Pounds (kg) for Various Occupancies Type of Refrigeration System Institutional Pub/Large Mercantile Residential Commercial Sealed Ammonia/Water Absorption System In public hallways or lobbies 0(0) 0(0) 3.3(1.5) 3.3(1.5) In adjacent outdoor locations 0(0) 0(0) 22(10) 22(10) In other than public hallways or lobbies 0(0) 6.6(3) 6.6(3) 22(10) Unit Systems In other than public hallways or lobbies 0(0) 0(0) 6.6(3) 22(10) 8.3 Safe Access. A clear and unobstructed approach and space shall be provided for inspection, service and emergency shutdown of condensing units, compressor units, condensers, stop valves and other serviceable components of refrigerating machinery. Access, including ladders, platforms, and clear space for inspection and servicing of condensing units, compressors, condensers, and other machinery, Permanent ladder, platforms or portable access equipment shall be provided in accordance with the requirements of the authority having jurisdiction. 8.4 Enclosures. Condensing units or compressor units with enclosures shall be readily accessible for servicing and inspection. 8.6 Illumination. Illumination adequate for inspection and servicing of condensing units or compressor units shall be provided. 8 8.13.2.1 Exceptions: (a) For ammonia refer to 8.14(g). 8.13.5 (b) Detectors not required when only systems using R-718 (water) are located in the refrigerating machinery room. (b) operable, when occupied if necessary for operator comfort, at a volume required to not exceed the higher of a maintain a maximum temperature rise of 18 F (10 C) above inlet air temperature or a maximum temperature of 122 o F (50 o C) based on all of the heat-producing machinery in the room. 3

8.13.6 No open flames that use combustion air from the machinery room shall be installed where any refrigerant is used. The use of matches, lighters, halide leak detectors, and similar devices shall not be considered a violation of 8.13.6. Combustion equipment shall not be installed in the same machinery room with refrigerant-containing equipment except under one of the following conditions: (a) combustion air is ducted from outside the machinery room and sealed in such a manner as to prevent any refrigerant leakage from entering the combustion chamber, or (b) a refrigerant vapor detector, conforming to 8.13.2.1, is employed to automatically shut down the combustion process in the event of refrigerant leakage. Exceptions: (1)Machinery rooms where only R-744 (carbon dioxide) or R- 718 (water) is the refrigerant. (2) Machinery rooms where only R-717 (ammonia) is the refrigerant and internal combustion engines are used as the prime mover for the compressors. 8.14 Machinery Room, Special Requirements. (h) When ammonia is used, the machinery room is not required to meet Class 1, Division 2, of the National Electric Code providing (1) the mechanical ventilation system in the machinery room is run continuously and failure of the mechanical ventilation system actuates an alarm or (2) the machinery room is equipped with a vapor detector, conforming to 8.13.2.1, except that will automatically start the mechanical ventilation system and actuate an alarm at a detection level not to exceed the detector shall alarm at 1000 ppm. 8.16 Purge Discharge. The discharge offrom purge systems shall be governed by the same rules as pressure-relief devices and fusible plugs (see 9.7.8) and shall be piped in conjunction with these devices. Exception: When R-718 (water) is the refrigerant 9.2.1 Design pressures shall not be less than pressure arising under maximum operating, standby, or shipping conditions. When selecting the design pressure, allowance shall be provided for setting pressurelimiting devices and pressure-relief devices to avoid nuisance shutdowns and loss of refrigerant. The ASME Boiler and Pressure Vessel Code 14 Section VIII, Division I, Appendix M, contains information on the appropriate allowances for design pressure. Refrigerating equipment shall be designed for a vacuum of 29.0 in Hg (3.12 kpa). Design pressure for lithium bromide absorption systems shall not be less than 5 psig (34.7 kpa gage). Design pressure for mechanical refrigeration systems shall not be less than 15 psig (103.4 kpa gage) and, except as noted in 9.2.2, 9.2.3, 9.2.4, and 9.2.5, shall 4

not be less than the saturation pressure (gage) corresponding to the following temperatures: (a) Lowsides of all systems: 80 F (26.7 C). (b) Highsides of all water-cooled or evaporatively cooled systems: 30 F (16.7 C) higher than the summer 1% wet-bulb for the location as applicable or 15 F (8.3 C) higher than the highest design leaving condensing water temperature for which the equipment is designed or 104 F (40 C), whichever is greatest. (c) Highsides of all air-cooled systems: 30 F (16.7 C) higher than the highest summer 1% design dry-bulb for the location but not lower than 122 F (50 C). 9.5.1 Pressure-Relief Valve Setting. Pressure-relief valves shall start to function at a pressure not to exceed the design pressure of the parts of the system protected. Exception: See 9.7.8.1 for relief valves that discharge into other parts of the system. 9.7.8.1 Pressure-relief devices required in 9.4 and 9.7 shall not discharge into the lowside of the system unless the pressure-relief device is a type not affected by back pressure and the lowside is equipped with pressure-relief devices capable of relieving any increased refrigerant quantity. Such a lowside pressure-relief device shall be set in accordance with 9.5.1 and vented to the outside of the building in accordance with 9.7.8. The application of pressure relief valves which discharge from a higher pressure vessel into a lower pressure vessel of the system shall comply with (a) and (b) below: (a)the sum of the set pressure of the pressure relief valve discharging into a lower pressure vessel within the system and the set pressure of the system relief valve, required by 9.7.8.1(b), shall not exceed the design pressure of the system protected with a relief valve in accordance with 9.7.1. (b)the capacity of the pressure relief valve protecting the part of the system receiving a discharge from a pressure relief valve protecting a higher pressure vessel shall be at least the sum of the capacity required in 9.7.5 plus the capacity of the pressure relief valve discharging into that part of the system. Exception: Hydrostatic relief valves 9.12 Service Provisions 9.12.1 All serviceable components of refrigerating systems shall be provided with safe access safely accessible. 9.12.2 Access, including ladders, platforms, and clear space for inspection and servicing of condensing units, compressors, condensers, 5

and other machinery, shall be provided in accordance with approved safety standards 5 and the requirements of the authority having jurisdiction. 9.12.3 Condensing units or compressor units with enclosures shall be provided with safe access without the need to climb over or remove any obstacles, or the use of portable access equipmentreadily accessible for servicing and inspection. 9.14.1 All refrigerant-containing parts or unit systems shall be tested and proved tight by the manufacturer at not less than the design pressure for which they are rated. Pressure vessels shall be tested in accordance with 9.3. 9.14.1.1 Testing Procedure. Tests shall be performed with dry nitrogen or another nonflammable nonreactive, dried gas. Oxygen, air, or mixtures containing them shall not be used. The means used to build up the test pressure shall have either a pressure-limiting device or a pressure reducing device and a gage on the outlet side. The pressure relief device shall be set above the test pressure but low enough to prevent permanent deformation of the system s components. Exceptions: (a) Mixtures of dry nitrogen, inert gases, nonflammable refrigerants allowed for factory tests. (b) Mixtures of dry nitrogen, inert gases, or a combination of them with flammable refrigerants in concentrations not exceeding the lesser of a refrigerant weight fraction (mass fraction) of 5% or 25% of the LFL are allowed for factory tests. (c) Compressed air without added refrigerant is allowed for factory tests provided the system is subsequently evacuated to less than 1,000 microns (132 Pa) before charging with refrigerant. The required evacuation level is atmospheric pressure for systems using R-718 (water) or R-744 (carbon dioxide) as the refrigerant 13 Listed Equipment Equipment listed by an approved nationally recognized testing laboratory and identified, as part of the listing, as being in conformance with this standard, is deemed to meet the design, construction of equipment, and factory test requirement sections of this standard for the refrigerants or refrigerants for which the equipment was designed. Add Water and footnote f to Table 1 as follows: TABLE 1 Refrigerant a, and Amounts b,e Quantity of Refrigerant per Occupied Space Refrigerant Chemical Lb per PPM 6

Number Name Chemical Formula 1000 ft 3 a,c by vol g/m 3 a,c Group A1 R-718 Water H 2 O f f f f The quantity is unlimited when R-718 (water) is used as the refrigerant APPENDIX D (This appendix is not part of this standard but is included for information purposes only.) INFORMATIVE REFERENCES This appendix contains full citations for informative references only. Full citations for normative references are listed in Appendix E. References in this standard are numbered in the order in which they appear in the document, and so the numbers for the normative references are shown for the convenience of the user. 1. NIOSH Pocket Guide to Chemical Hazards (1985), U.S. Department of Health and Human Services, Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402. (IDLH definition) 2. Not an informative reference. 3. ACGIH Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices (1990-1991), American Conference of Governmental and Industrial Hygienists, Cincinnati, OH. 4. Not an informative reference 5. ANSI/NFPA 101-1988, Code for Safety to Life from Fire in Buildings and Structures, National Fire Protection Association (NFPA), Quincy, MA 02269. 6. ANSI/ASME B15.1-1984, Safety Code for Mechanical Power Transmission Apparatus and Addendum B15.1-A-1986, American Society of Mechanical Engineers (ASME), New York, NY 10017. 7. ANSI/UL 303-1987,UL 1995-95 Heating and Cooling Equipment Refrigeration and Air-Conditioning Condensing and Compressor Units, Underwriters Laboratoryies Inc. Northbrook, IL 60062 8. ANSI/IES RP-7-1983, Practice for Industrial Lighting, Illuminating Engineering Society of North America (IES), New York, NY 10017. 9. Not an informative reference. 10. NFPA Standard 54-1988 (ANSI Z223.1-1988), National Fuel Gas Code, National Fire Protection Association (NFPA), Quincy, MA 02269. 7

11. ANSI/NFPA 37-1990, Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines, National Fire Protection Association (NFPA), Quincy, MA 02269. 12. ANSI/NFPA 90A-1989, Standard for the Installation of Air Conditioning and Ventilating Systems, National Fire Protection Association (NFPA), Quincy, MA 02269. 13. ANSI/NFPA 90B-1989, Standard for the Installation of Warm Air Heating and Air Conditioning Systems, National Fire Protection Association (NFPA), Quincy, MA 02269. 14. Not an informative reference. ASME Boiler and Pressure Vessel Code, Section VIII, Rules for Construction of (Pressure Vessels, Division 1, 1992, American Society of Mechanical Engineers (ASME), New York, NY 10017. 15. Not an informative reference. ASME/ANSI B31.5-1987, Refrigeration Piping and Addendum B31.5A-1989, American Society of Mechanical Engineers (ASME), New York, NY 10017. 16. Not an informative reference. 17. Not an informative reference. 18. Not an informative reference. 19. Not an informative reference. 20. Not an informative reference. 21. U.S. Department of Transportation Code of Federal Regulations 49, TRANSPORTATION, Parts 100-199, "Regulations for Transportation of Explosive and other Dangerous Articles by Land and Water in Rail Freight Service and by Motor Vehicle (Highway) and Water, Including Specifications for Shipping Containers." Revised at least once each calendar year and issued as of October 1. U.S. Department of Transportation (DOT), Office of Hazardous Materials, Transportation, Washington, DC 20590. 22. NFPA 68-1988, Guide for Venting of Deflagrations, National Fire Protection Association (NFPA), Quincy, MA 02269. 23. USAF Facility Design and Planning Engineering Weather Data, AFM 88-29, Department of the Air Force, the Army, and the Navy, Washington, DC. 24. ASHRAE Handbook of Fundamentals, 1989 8

25. IIAR Bulletin 114, 9/91, Guidelines for Identification of Ammonia Refrigeration Piping and System Components, International Institute of Ammonia Refrigeration, 1101 Connecticut Ave, N.W. Washington, DC 20036. 26. Not an informative reference APPENDIX E (This appendix is part of this standard, and is required for its use.) NORMATIVE REFERENCES This appendix contains full citations for normative references. Full citations for references that are solely informative are included in Appendix D. Note that in some locations within the standard, normative references are also used as informative references. References in this standard are numbered in the order in which they appear in the document, and so the numbers for the informative references are shown for the convenience of the user. 1. Not a normative reference. 2. ASTM D93-85, Standard Test Methods for Flash Point by Pensky- Martens Closed Tester, American Society for Testing and Materials (ASTM), Philadelphia, PA 19103. 3. Not a normative reference. 4. ANSI/ASHRAE 34-1997 with addenda a-f, Designation and Safety Classification of Refrigerants, American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc., Atlanta, GA, 30329., 5. Not a normative reference. 6. ANSI/ASME B15.1-1984, Safety Code for Mechanical Power Transmission Apparatus and Addendum B15 1-A 1986, American Society of Mechanical Engineers (ASME), New York, NY 10017., 7. ANSI/UL 303-1987, UL 1995-95 Heating and Cooling Equipment Refrigeration and Air-Conditioning Condensing and Compressor Units, Underwriters Laboratoryies Inc. Northbrook, IL 60062, 8. ANSI/IES RP-7-1983, Practice for Industrial Lighting, Illuminating Engineering Society of North America (IESNA), New York, NY 10017., 9. ANSI/NFPA 70-1999, National Electrical Code, National Fire Protection Association (NFPA), Quincy, MA 02269. 10. NFPA Standard 54-1988 (ANSI Z223.1-1988), National Fuel Gas Code, National Fire Protection Association (NFPA), Quincy, MA 02269. 9

, 11. ANSI/NFPA 37-1990, Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines, National Fire Protection Association (NFPA), Quincy, MA 02269., 12. ANSI/NFPA 90A-1989, Standard for the Installation of Air Conditioning and Ventilating Systems, National Fire Protection Association (NFPA), Quincy, MA 02269., 13. ANSI/NFPA 90B-1989, Standard for the Installation of Warm Air Heating and Air Conditioning Systems, National Fire Protection Association (NFPA), Quincy, MA 02269., 14. ASME Boiler and Pressure Vessel Code, Section VIII, Rules for Construction of Pressure Vessels, Division 1, 1992, American Society of Mechanical Engineers (ASME), New York, NY 10017., 15. ASME/ANSI B31.5-1987, Refrigeration Piping and Addendum B31.5A- 1989, American Society of Mechanical Engineers (ASME), New York, NY 10017. and producers of refrigerating equipment. For all other users, 16. ANSI/ASTM B88-89 96, Standard Specification for Seamless Copper Water Tube, American Society for Testing and Materials (ASTM), Philadelphia, PA 19103 100 Barr Harbor Drive, West Conshohocken, PA 19428. 17. ANSI/ASTM B280-88 94A, Standard Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service, American Society for Testing and Materials (ASTM), Philadelphia, PA 19103 100 Barr Harbor Drive, West Conshohocken, PA 19428. 18. ASTM B68-86 95, Standard Specification for Seamless Copper Tube, Bright Annealed, American Society for Testing and Materials (ASTM), Philadelphia, PA 19103 100 Barr Harbor Drive, West Conshohocken, PA 19428. 19. ASTM B75-86 95A, Standard Specification for Seamless Copper Tube, American Society for Testing and Materials (ASTM), Philadelphia, PA 19103 100 Barr Harbor Drive, West Conshohocken, PA 19428. 20. ANSI A13.1-1981 (R1985), Scheme for the Identification of Piping Systems, American Society of Mechanical Engineers (ASME), New York, NY 10017. 21. U.S. Department of Transportation Code of Federal Regulations 49, TRANSPORTATION, Parts 100-199, "Regulations for Transportation of Explosive and other Dangerous Articles by Land and Water in Rail Freight Service and by Motor Vehicle (Highway) and Water, Including Specifications for Shipping Containers." Revised at least once each calendar year and issued as of October 1. U.S. Department of Transpor- 10

tation (DOT), Office of Hazardous Materials, Transportation, Washington, DC 20590., 22. Not a normative reference. 23. Not a normative reference. 24. Not a normative reference. 25. Not a normative reference. 26 ANSI/ARI 700-1995, Specifications for Fluorocarbon and Other Refrigerants, Air-Conditioning & Refrigeration Institute, 4301 North Fairfax Drive, Arlington, VA 22203. Note: The references remaining will have to be renumbered and the superscript in the text changed to reflect the new numbers of the references. 11