Prevents condensation

Similar documents
Prevents! Moisture Control Tube. Diffuses water vapor in the piping to the outside! Series IDK

Prevents condensation

Moisture Control Tube

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

Refrigerated Air Dryer

Refrigerated Air Dryers

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

Refrigerated Air Dryers

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Pressure Switches Precautions 1 Be sure to read this before handling.

Multistage Ejector MODEL / Series / Product Number

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Refrigerated Air Dryer

Refrigerated Air Dryers

TUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS

Refrigerated Air Dryers

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.

Hollow Fiber Membrane Filter Type Air Drier Unit Type

Complex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator VN Series

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).

External Vacuum Controller with compact and lightweight body, achieving shorter blow-off time. External Vacuum Controller Series

Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.

Discrete type for different piping conditions VSH/VSU/VSB/VSC. Features

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification

Module 7: Air Supply System

Ultrasonic Aroma Diffuser AD-SD1-CE

ULTRA LOW TEMPERATURE FREEZER. User Manual

Space Saving Vacuum Ejector Vacuum Pump System MODEL / Series / Product Number

Model Selection. Data. Selection Graph. Selection Graph (2) Piping Capacity by Tube I.D.

SYNRAD Technical Bulletin # 0015d

13-1. Temperature Regulator

IDU22C, 22C1, 37C, 37C1, 55C, 75C

Refrigerated Air Dryer

Residential Piping and Long Line Guideline

Main Characteristics of Appliances for Transport and Compression of Air

Sullair Drains for Compressed Air Systems Zero Air Loss and Timed Solenoid

Refrigerated Air Dryer

Homework Chapter2. Homework Chapter3

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

Condensate Management Solutions

PNEUMATIC & HYDRAULIC SYSTEMS

Ozomax Ltd Ozone generators

KINNEY OIL MIST ELIMINATORS

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

BITUMINOUS DIGITRAC AUTO STABILITY PRESS MARSHALL AUTOMATIC DIGITAL TESTER MARSHALL TESTING MACHINE W/ RECORDER MODELS

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

Model DH-10 Dehumidifier

Refrigerated Air Dryer Large Size Series

% by up ctoond re-heater and

Instruction Manual. Portable Air Conditioner

Refrigerated Air Dryer

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Psychrometrics. Outline. Psychrometrics. What is psychrometrics? Psychrometrics in daily life and food industry Psychrometric chart

USER S MANUAL AND INSTALLATION INSTRUCTIONS IMPORTANT

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Refrigeration air dryer

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

Valve timing. Atmospheric air

PRO 2000i LOW LEVEL DEPOSITOR

B.Tech. First Semester Examination Basics of Mechanical Engineering (ME-101F)

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Installation Guide & Owner s Manual

Industrial Refrigeration. Brochure R/S CB 02/10

Chapter 9. Refrigeration and Liquefaction

Pressure Enthalpy Charts

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

OPERATION & MAINTENANCE MANUAL TX600

Vacuum Generators. Ejector for Various Piping Conditions

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

Evaporative Cooling products

HEATLESS REGENERATIVE DRYERS

Inta City Concealed Shower Mixing Valve CT80010CP

DBF 4XL Dryer Booster Fans

Permission granted to reproduce for educational use only. Describe the problems caused by excess

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252

LONG LINE SET APPLICATION R-410A

Owner s Information Manual

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

INSTRUCTIONS REHAU SILENT DIAL THERMOSTAT #

P3X Series Membrane dryers

Refrigerated Air Dryer

OIL/WATER SEPARATORS. Compressed Air & Process Filtration

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS

Insty-Pac Steam Humidifiers

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Chapter B-2. Chapter 2. Air generation and distribution. Festo Didactic TP101

Semi Auto Bottle-blowing Machine Mode: JND-880

Cost reduced by up to /year! Purge air flow rate (rated conditions) Running cost [ /year] Model IDG50A

AIR FILTER + REGULATOR + LUBRICATOR AIR FILTER. Series : V050, V100, V200, V250, V300

microjet LINK GmbH Minimum-quantity lubricating systems a solution to every application! microjet Nozzle technology Modular system Sawing technique

CKD refrigerating type dryer

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

Instruction Manual, Rotary Spray Heads

Application note. LCD Module. Precautions for LCM handling. LCM handling V 1.1

[FLARE CONNECTION TYPE] ATTENTION

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

Instructions manual DEHUMID HP50

Transcription:

Moisture Control Tube Series Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! Water vapor dditional power supply and works are not necessary! ll you have to do is install the moisture control tube!! No condensation Water vapor Moisture control tube Linear shape Suitable for applications where cylinders do not rotate. Current piping Water vapor General tube Coil shape Reduces tube buckling of moving part. Condensation generated Operating a small cylinder, air gripper, or air operated valve, etc. which has a small volume may cause condensation of water in the near the actuator due to the volume ratio of the actuator volume and the operating piping volume. H HW T U FS B G MG FF M MD MH ME MF D D 191

Moisture Control Tube Series Prevents condensation issue with pneumatic equipment. If condensation occurs... Grease deteriorates or is washed away. Operation failure Supply Shorter life ir quality affects the operation and the life of the equipment in a pneumatic system, so dehumidified air is necessary. In particular, if small actuators are continuously operated at high frequency, condensation may be generated even with dehumidified air, due to the characteristics of the system. The moisture control tube prevents condensation from being formed by diffusing water vapor generated in the piping to the outside before the water vapor is condensed. The mechanism of condensation in small actuators Exhaust Supply q The temperature in the piping rapidly drops due to adiabatic expansion. w If the temperature in the piping becomes lower than the dew point of the compressed air, vapor will be generated. e The vapor cannot be exhausted (cannot be pushed out) as the volume of the actuator is small. Residual vapor is pressed by compressed air and accumulates in the near the actuator. Vapor builds up on the cylinder side. Vapor is generated. Piping (Tube) Solenoid Exhaust valve Piping (Tube) New compressed air Solenoid Supply valve Equipment in which condensation is a possibility Small diameter cylinders/air grippers 192 ir operated valves (Pilot port)

Moisture Control Tube Series dditional power supply and works are not necessary! Just by installing the moisture control tube prevents condensation. Linear shape Coil shape Suitable for applications where cylinders do not rotate. Since other tubes with a small bending radius are used on moving parts, the buckling trouble of the moisture control tubes can be reduced. Moisture control tube Linear shape Moisture control tube Coil shape Polyurethane tube H HW T U FS Polyurethane tube Reduces tube buckling! B Rotational movement Tube O.D. Model 2 Tube effective length 2 ø2 4 ø4 6 ø6 Tube O.D. Model 4 Tube effective length 2 ø4 mm MG ø6 mm G 2 mm 6 FF 2 mm M MD MH The accumulated vapor is liquefied (condensed) due to repeated supply/exhaust. ME MF Condensation Piping (Tube) Condensed water Supply Solenoid Exhaust valve D Water droplets Grease deteriorates or is washed away. D Operating principle of moisture control tube This moisture control tube has characteristics to balance the humidity inside the tube with that outside the tube. If the humidity inside the tube differs from that outside the tube, the moisture control tube penetrates the water vapor from the higher humidity side to the lower humidity side. The moisture control tube penetrates only the water vapor and rarely penetrates the air. The humidity inside the tube is put in the high humidity status due to the mist generated every exhaust, causing dew condensation. The moisture control tube penetrates the generated mist from the inside of the tube with a high humidity to its outside with a low humidity to prevent accumulation of water vapor and dew condensation inside the tube. Low humidity Mist is generated due to rapid temperature decrease during exhaust. ir Water vapor High humidity Outside of tube Inside of tube The water vapor is generated and it moves from the inside of the tube with a high humidity to its outside with a low humidity. 193

Moisture Control Tube Series Specifications (Linear Shape) Model 2 4 6 Fluid Note 1) Compressed air Max. operating pressure.7 MPa Operating temperature to 6 C (No freezing) Operating environment Note 2) Indoors, where product is not exposed to water ( to 4 C, to 75%RH) Min. bending radius *2 [mm] 1 2 4 Quantity of moisture control tubes 2 pcs. Color Transparent Color will change to brown over time, but the functions are not affected. pplicable fittings Note 4) KQ2 Material Fluoropolymer Note 1) Use the moisture control tube in a compressed air line with a refrigerated air dryer and a mist separator installed upstream. The condensation prevention performance may be lowered depending on the quality of the supply compressed air (oil, dew point). Note 2) Use in a low-humidity environment. If the ambient humidity is higher, condensation prevention may not occur. Note 3) The minimum bending radius is the radius at which the tube breaks or flattens at a temperature of 2 C. In actual applications, the tube and inner sleeve should be used in a manner in which breakage, flattening, etc., does not occur. Note 4) The inner sleeve is already mounted and cannot be removed. 2 Inner sleeve If the inner sleeve happens to come off, re-insert it before mounting the fitting. Note 5) Do not cut the tube. R Dimensions Tube O.D. Symbol O.D. 2 2 mm 4 4 mm 6 6 mm How to Order 2 Tube nominal length Symbol Nominal length mm 2 2 mm D L X Inner sleeve Model O.D. x I.D. D Nominal length X Unit: mm Full length L 2-12 2 x 1.2 2-2 2 22 4-14 4 x 2.5 4-2 2 24 6-14 6 x 4 6-2 2 24 Note) Dimensions at 4% relative humidity. Dimensions may change if the relative humidity changes. B Made to Order If you require the moisture control tube with a nominal length not listed in the above table, please contact SMC. 194

Moisture Control Tube Series Specifications (Coil Shape) Dimensions (per tube) 4--C1 () (ø2) 6--C1 Width: Min.(12) Max.(2) øcoil O.D.: (ø24) (24) Section B Width: Min.(14) Max.(2) Model 4- -C1 6- -C1 Fluid Note 1) Compressed air Max. operating pressure.7 MPa Fluid temperature to 6 C (No freezing) Operating environment Note 2) Indoors, where product is not exposed to water ( to 4 C, to 75%RH) Quantity of moisture control tubes 2 pcs. Color øcoil O.D.: (ø15) øcoil O.D.: (ø3) Transparent Width: Min.(3) Max.(4) Section B Width: Min.(2) Max.(3) Color will change to brown over time, but the functions are not affected. pplicable fittings Note 3) KQ2 Material Fluoropolymer Note 1) Use the moisture control tube in a compressed air line with a refrigerated air dryer and a mist separator installed upstream. The condensation prevention performance may be lowered depending on the quality of the supply compressed air (oil, dew point). Note 2) Use in a low-humidity environment. If the ambient humidity is higher, condensation prevention may not occur. Note 3) The inner sleeve is already mounted and cannot be removed. If the inner sleeve happens to come off, re-insert it before mounting the fitting. 4-2-C1 6-2-C1 How to Order (26) 4 C1 Tube O.D. Symbol O.D. 4 4 mm 6 6 mm Note) Part number for a set of 2 tubes Coil shape Tube nominal length Symbol Nominal length mm 2 2 mm Section B details Inner sleeve (Stainless steel) Tube O.D. 4: ø4 6: ø6 H HW T U FS B G MG FF M MD MH ME (4) (42) MF D D Section B Section B * Due to the material, the above dimensions may vary depending on the environment (temperature, humidity) including the spread of dimension. 195

Series Table for Quick Selection Refer to pages 198 and 199 for details of Model Selection. Basic conditions for selection Supply air pressure:.5 MPa Supply air dew point: 2 C (tmospheric pressure dew point) mbient environment: mbient temperature 25 C, mbient humidity 4% * If your operating conditions are different from these basic conditions, correct them based on Model Selection. Single Piston ctuator size Piping condition Recommended model Bore size [mm] Stroke [mm] 2.5 ll strokes 4 ll strokes 6 8 1 16 (15) 2 Less than 1 1 or more Less than 1 1 or more Less than 1 1 or more Less than 1 1 or more Less than 1 1 or more Tube length Tube O.D. 2 mm Tube O.D. 4 mm Tube O.D. 6 mm [m] 2-2-2 4- (-C1) 4-2 (-C1) 6- (-C1) 6-2 (-C1) 5 V V V 5 V V V 5 V V V 5 V V V 5 V V V Dual Piston Series CXWM, CXWL (CXWl-25 or less) MXQ ctuator size Piping condition Recommended model Bore size Stroke Tube length Tube O.D. 2 mm Tube O.D. 4 mm Tube O.D. 6 mm [mm] [mm] [m] 2-2-2 4- (-C1) 4-2 (-C1) 6- (-C1) 6-2 (-C1) 1 25 5 1 V 6 1 Size larger than those above 6 1 CXS, CXSJ Size larger than those above Note) If the piping is longer than the above tube length, the l-2 may be necessary. 196

Table for Quick Selection Series Basic conditions for selection Supply air pressure:.5 MPa Supply air dew point: 2 C (tmospheric pressure dew point) mbient environment: mbient temperature 25 C, mbient humidity 4% * If your operating conditions are different from these basic conditions, correct them based on Model Selection. ir Gripper Series Piping condition Recommended model Bore size Tube length Tube O.D. 2 mm Tube O.D. 4 mm Tube O.D. 6 mm [mm] [m] 2-2-2 4- (-C1) 4-2 (-C1) 6- (-C1) 6-2 (-C1) MHZ2, MHZJ2 6 5 V V V MHZ2, MHZJ2 6 MHC2 6 5 V V V MHC2 6 5 V V V MHCM2 7 5 V V V ir gripper with bore size larger than those above V V V Rotary ctuator Series CRBl CRBU2 MSUl Vane type Single Size 1 Double 1 Single Rotating angle 18 27 15 1 18 3 Double 1 CRQ2 1 MSQl 1 2 3 18 Note) If the piping is longer than the above tube length, the l-2 may be necessary. Piping condition Recommended model Tube length Tube O.D. 2 mm Tube O.D. 4 mm Tube O.D. 6 mm [m] 2-2-2 4- (-C1) 4-2 (-C1) 6- (-C1) 6-2 (-C1) 197 H HW T U FS B G MG FF M MD MH ME MF D D

Series Model Selection Selection Procedure 1 Check the presence of condensation. 2 Select the length of moisture control tube for the condensation. (1) The presence of condensation can be verified by the dew point and (1) Find L1, the necessary length to prevent condensation at basic conditions corresponding Kv value (the volume ratio of tube and actuator) of the supply air. to the Kv value, from the length selection chart at basic conditions. Fig.1 Verification Chart of Condensation Supply air dew point (tmospheric pressure dew point) [ C] 1 2 3 4 5 Noncondensation Condensation.4 MPa.5 MPa.6 MPa.7 MPa Fig. 3 Length Selection Chart at Basic Conditions 3 Necessary length to prevent condensation at basic conditions L1 [mm] 25 2 15 5 O.D. 2 mm tube O.D. 6 mm tube O.D. 4 mm tube Basic conditions Supply air dew point: 2 C (tmospheric pressure dew point) Supply air pressure:.5 MPa Solenoid valve operating intervals: 1 s (ON) 1 s (OFF) mbient mbient temperature: 25 C environment mbient humidity: 4% 6 2 4 6 8 2 4 6 8 Supply air dew point (tmospheric pressure dew point) [ C] Piping volume [mm 3 ] 1 2 3 4 Volume ratio [Kv] Enlarged View of Portion Within Dotted Lines Condensation.4 MPa.5 MPa.6 MPa.7 MPa Noncondensation 5 6 2 4 6 8 12 14 16 18 2 Volume ratio [Kv] Calculation method of volume ratio (Kv value) Calculate the piping volume Vt and the actuator volume Vc and substitute them into equation q below. Vt Kv = q Vc Vt = pd2 l 4 Vc = pd2 s 4 Fig. 2 Piping Volume Chart 198 Kv : Volume ratio Vt : Piping volume [mm 3 ] Vc : ctuator volume [mm 3 ] Vt : Piping volume [mm 3 ] [can be selected from piping volume chart in Fig. 2.] d : Tube I.D. [mm] l : Tube length [mm] * Tube length means the tube piping length from the switch valve (e.g. solenoid valve) to the actuator. Vc : ctuator volume [mm 3 ] D : Bore size [mm] s : Stroke [mm] 14 12 ø6 tube 8 6 ø4 tube 4 2 2 4 6 ø2 tube 8 12 Tube piping length from the switch valve to the actuator [mm] Necessary length to prevent condensation at basic conditions L1 [mm] 8 7 6 5 4 3 2 1 Kv value Enlarged View of Portion Within Dotted Lines O.D. 6 mm tube O.D. 4 mm tube O.D. 2 mm tube Basic conditions Supply air dew point: 2 C (tmospheric pressure dew point) Supply air pressure:.5 MPa Solenoid valve operating intervals: 1 s (ON) 1 s (OFF) mbient environment mbient temperature: 25 C mbient humidity: 4% 2 4 6 8 12 14 16 18 2 Kv value (2) If your operating conditions are different from these basic conditions, apply a correction factor. Necessary length to prevent condensation L = Necessary length to prevent condensation at basic conditions L1 x C1 x C2 x C3 Correction Factor C1 for Supply ir Dew Point Supply air dew point Correction factor [ C] C1 1 2 2 1 3.5 4.25 Correction Factor C2 for mbient Environment Temperature Correction factor C2 Relative humidity 1 C 25 C 4 C 6 C 2%.2.4.6.8 4%.5 1. 1.3 1.8 6% 1. 1.7 2.8 3.7 75% 2.1 4. 5.9 7.8 Correction Factor C3 for Supply ir Pressure Supply pressure Correction factor [MPa] C3.3.4.4.7.5 1.6 1.25.7 1.6 (3) Based on the calculated L value, select the m- or m-2. * If the L value is 2 or larger, a fitting should be connected to the m- and m-2 before use.

Model Selection Series Selection Example Circuit conditions ctuator : CUJB4-6D Bore size D : 4 mm Stroke s : 6 mm Tube size : O.D. 6 mm x I.D. (Tube I.D. d) 4 mm Tube piping length l : 5 m Supply air pressure :.3 MPa Supply air dew point : 2 C (tmospheric pressure dew point) mbient environment : mbient temperature 25 C, mbient humidity 6% 1 Check the presence of condensation. Check the presence of condensation. (1) Calculation method of volume ratio (Kv value) pd Vt = 2 l p x 4 2 x 5 = = 628 mm 3 4 4 pd Vc = 2 s p x 4 2 x 6 = = 75 mm 3 4 4 Vt Kv = = 837 Vc Fig.1 Verification Chart of Condensation Supply air dew point (tmospheric pressure dew point) [ C] Note) For dual piston cylinder, the volume ratio will be 1/2 of the volume ratio calculated above. Verify the presence of condensation. (2) Refer to the verification chart of condensation. Check whether the volume ratio [Kv] and the supply air dew point intersect in the condensation. With the conditions above, they intersect in the condensation, meaning condensation will occur. 1 2 3 4 5 Confirmed that the intersection is in the condensation Noncondensation.4 MPa Condensation.5 MPa.6 MPa.7 MPa 6 2 4 6 8 Volume ratio [Kv] 2 Select the length of moisture control tube. (1) Find L1, the necessary length to prevent condensation at basic conditions, from the length selection chart at basic conditions and Kv value. Fig. 2 Length Selection Chart at Basic Conditions Necessary length to prevent condensation at basic conditions L1 [mm] 3 25 2 15 5 L1 at basic conditions is 18 mm. O.D. 6 mm tube O.D. 4 mm tube O.D. 2 mm tube Basic conditions Supply air dew point: 2 C (tmospheric pressure dew point) Supply air pressure:.5 MPa Solenoid valve operating intervals: 1 s (ON) 1 s (OFF) mbient environment mbient temperature: 25 C mbient humidity: 4% 2 4 6 8 Kv value (2) If your operating conditions are different from these basic conditions, apply a correction factor. Necessary length to prevent condensation L = Necessary length to prevent condensation at basic conditions L1 x C1 x C2 x C3 In the example circuit, the conditions which are different from the basic conditions are: * Basic conditions Supply air dew point: 2 C Supply air dew point: 2 C (tmospheric pressure dew point) (tmospheric pressure dew point) Supply air pressure:.3 MPa Supply air pressure:.5 MPa mbient environment: 25 C, 6% mbient environment: 25 C, 4% (a) Find the correction factors. Supply air dew point correction factor C1 = 1 mbient environment correction factor C2 = 1.7 Supply air pressure correction factor C3 =.4 (b) Find the necessary effective length after correction. Necessary length to prevent condensation L = 18 x 1 x 1.7 x.4 12 mm (3) Therefore, the moisture control tube 6-2 with effective length 2 cm should be used. H HW T U FS B G MG FF M MD MH ME MF D D 199

Series Specific Product Precautions 1 Be sure to read this before handling the products. Refer to back page 5 for Safety Instructions and pages 6 to 8 for ir Preparation Equipment Precautions. Design 1. Use the moisture control tube without lubrication. 2. Do not cover the moisture control tube or use in an enclosed space. Water vapor escapes outside of the moisture control tube. Covering the moisture control tube will reduce the performance and condensation cannot be prevented. 3. The exterior dimensions will change depending on the temperature and humidity. If the product is left in an environment which exceeds the specifications of 4 C and 75% RH relative humidity, the outer diameter will increase and it will become difficult to insert and remove it from the One-touch fitting. In such cases, please refrain from inserting and removing the product with force. Perform insertion and removal in a location with a lower temperature and lower humidity. 4. s the product is used to prevent condensation during use, the outer diameter of the tubing will increase and it may become difficult to remove it from the One-touch fitting. In such cases, wait for a short while after operation has been stopped before removing the tubing. 5. The color of the moisture control tube will turn to brown over time due to reaction with organic substances in the air. This does not affect the performance or strength. 6. Do not wipe or clean the product with alcohol. Only air blow should be performed. 7. The moisture control tube is assumed to be used for static piping. If the tube moves, for example in a flexible moving tube, it may become worn, elongated or torn due to tensile forces, or disconnected from the fitting. Ensure the tube is in a static condition at all times before using. Operating Environment 1. The moisture control tube is for indoor use. It cannot be used under water or where it is exposed to water. 2. Do not use this product in locations where there are problems with static electricity. 3. Do not use this product in locations where spatter is generated. 4. Do not use in an environment where the product is directly exposed to cutting oil, lubricant, coolant oil, etc. 2 Operating Environment 5. Do not use in environments where foreign matter may stick to the product or get mixed in the product s interior. 6. void high temperature and humidity in the operating environment. They will reduce the performance of the tube and condensation may be generated. Mounting/Piping 1. Do not use the moisture control tubes bundled together. Otherwise, the performance may be decreased. 2. Connect the tube directly to the fitting of the actuator or air operated valve. If the tube is connected to other places, condensation will not be prevented and vapor will be gener ated. Mounting position Moisture control tube Solenoid valve Supply air Moisture control tube Supply air Switch air for air operated valve ir operated valve 3. Clean the tube and actuator by air blowing to eliminate moisture before connecting them to the circuit with condensation. When condensation is being generated in the tubing of an actuator, it is possible that all the required grease has been washed away. Make sure to mount the moisture control tube after adding grease to the actuator. 4. Mount the tube with minimum bending radius or more. Be careful not to bend or flatten the tube even if the bending radius is more than the minimum value. The moisture control tube is not suit able for the place where the product slides in high frequency. Do not stretch or shake this product when using. 5. When connecting this product to a fitting, hold the tube and slowly push the tube straight ( to 5 ) into the fitting until it stops. Pull the tube back gently to make sure that it is connected firmly. If the tube is not installed correctly, it may cause air leaks, or the tube may be disconnected. s a guide, connect the tube to the fitting until the inner sleeve is not visible from the fitting.

Series Specific Product Precautions 2 Be sure to read this before handling the products. Refer to back page 5 for Safety Instructions and pages 6 to 8 for ir Preparation Equipment Precautions. TU64 Mounting/Piping 6. Install a refrigerated air dryer and a mist separator in the upstream compressed air line. The condensation prevention performance may be lowered depending on the quality of the supply compressed air (oil, dew point). Recommended Model Description Refrigerated air dryer Mist separator Model /U M/FM 7. Select the moisture control tube with the same diameter as the tube connected. Example) TU64 6 l TU64 6 KQ2H6- * One-touch fitting (KQ2H6-) is not included. 8. Do not cut this product or use it without the inner sleeve. The inner sleeve cannot be removed. If the inner sleeve comes off, re insert the inner sleeve into the tube again before mounting it to the fitting. 9. The only fittings this product can be used with are the KQ2 and KJ series One touch fittings and their corresponding equipment (speed controllers, rotary One touch fittings, etc.) Other fittings cannot be used. Others 1. The moisture control tube is a product to prevent condensation of actuating parts such as small actuators and air operated valves. If you wish to use the product for any other application, please contact SMC. 2. Store the moisture control tube without unpacking. fter unpacking the product, store it at a temperature of 4 C or less and relative humidity of 75% or less. 3. When the moisture control tube (coil shape) is stored or used for long periods, the dimensions and shape may change. Note that the shape of this product tends to change easily, particularly in high temperature and humidity environments. H HW T U FS B G MG FF M MD MH ME MF D D 21