For Service Only. Installation Instructions EXD-3/WH97. Express Deck Lavatory System EXD Series

Similar documents
For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

Installation Instructions OBSOLETE

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Terreon Lav Decks WARNING

Installation LD3060. OmniDeck Series. Table of Contents Rev. R; ECM Bradley Corporation Page 1 of 10 3/30/11

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

Installation LC800. Patient Care Unit, 47", Fixed Water Closet. Table of Contents

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

Installation LC840. Patient Care Unit, 40", Fixed Water Closet. Table of Contents

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

Installation Instructions

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

LA90 DISCONTINUED IMPORTANT!

LA45 DISCONTINUED IMPORTANT!

LA60 DISCONTINUED IMPORTANT!

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

Installation WARNING SXWS9561. Stainless Steel Panel Shower

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation Instructions

Express Lavatory System SS-Series

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation. S Series Navigator Thermostatic Mixing Valve

Models: FM FM WARNING

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation IMPORTANT! Bradley Multi-Station Wall Sink

SS-1N Express Lavatory System SS-Series

Installation LVQD2. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

Installation Instructions

Installation Instructions

Installation LVQD1. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

PAT BASIN MODEL 9121, 9131, & 9141

Installation S

Installation S

Installation S

Installation S

1/7 SPOUT INSTALLATION

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

Installation S

Installation Instructions

Installation Instructions

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

ACRYLIC PEDESTAL TUB

MERIDIAN MODEL# 3793

Installation Instructions

Installation Instructions

ACRYLIC CLAWFOOT TUB

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

STOP RESIN TUB WITH INTEGRAL DRAIN PLANNING BEFORE YOU BEGIN TOOLS AND MATERIALS: GETTING STARTED INSTALLATION INSTRUCTIONS.

Installation Instructions

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS

Installation Instructions

AV30 Advocate Lavatory System AV-Series

? Teflon Tape? 9/16 Fixture Wall Anchors and. ? 9/32 Fixture Wall Anchors and

OWNER S MANUAL WISTERIA

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Basin Set INSTALLATION INSTRUCTIONS

STOP ACRYLIC TUB WITH INTEGRAL DRAIN PLANNING BEFORE YOU BEGIN TOOLS AND MATERIALS: GETTING STARTED INSTALLATION INSTRUCTIONS.

FL-2H, FL-2L Frequency Lavatory System FL-Series

owner s manual produitsneptune.com Do not discard. Save these instructions for further use.

CAST IRON CLAWFOOT TUB

INSTALLATION AND CARE GUIDE MARCO VANITY FRAME BASE & SINKTOP E E E E052463

STAINLESS STEEL TUB INSTALLATION

Acrylic Claw Foot Tub

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

GRANITE COMPOSITE SINK

Installation & Operation Manual

ROHL Modern Bath Lombardia/Architectural ROHL Transitional Bath Avanti COLORS/FINISHES. Polished Chrome Polished Nickel Satin Nickel

Installation S IMPORTANT! Bradley Thermostatic Mixing Valve for Individual Showers. Table of Contents

Oahu Showerspa Model #1035 Owner's Manual

AV90 Advocate Lavatory System AV-Series

Installation & Operation Manual

3/4 HP Model Trimmer Operating Instructions

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

AV60 Advocate Lavatory System AV-Series

RIO. Rio ShowerSpa Model #1049B-BN Owner s Manual

WAIMEA. Waimea Showerspa Model #1034 Owner's Manual

SS-3N Express Lavatory System SS-Series

INSTALLATION INSTRUCTIONS

R7521SS COLORS/FINISHES. Stainless Steel 21 15/16" 1 3/16" 8 5/64" 1 25/32" 2 1/8" 23 5/8" Max. 1 3/8" G1/2" Female

Installation Instructions

NIAGARA. Niagara ShowerSpa Model #1048B-BN Owner s Manual

INSTALLATION AND OPERATION INSTRUCTIONS LC-D SERIES COFFEE CONCENTRATE BREWER WITH DIGITAL ELECTRONIC CONTROL CENTER

Syrup Server. Thank You MODEL: SY MODEL: SY for purchasing this Syrup Server to heat and neatly dispense sticky syrups and sauces.

R7520SS COLORS/FINISHES. Stainless Steel 16 9/16" 7 15/16"

Single Handle Lavatory Faucet

Installation. S19-320A (6' cable) S19-320D (12' cable) Flow Switch Alarm System. Table of Contents

DISCONTINUED. Installation. S19-320A (6' cable) S19-320D (12' cable) Flow Switch Alarm System. Table of Contents

Transcription:

Installation Instructions For Service Only Express Deck Lavatory System EXD Series Express Decks are ADA compliant. Table of Contents Dimensions.............................2 Installation Instructions................. 3-8 Cleaning and Maintenance.................8 Assembly of Components..................9 Vernatherm Valve......................10 IMPORTANT Read this entire installation manual to ensure proper installation, then file these instructions with the owner or maintenance department. Flush all the water supply lines before making connections. Debris in supply lines will cause the valves to malfunction. Turn OFF electrical power to the outlet when installing the Express Deck. Wall anchors used must have a minimum pull-out rating of 1,000 lbs. Darker-colored solid surface materials require more maintenance and are susceptible to blushing in applications where water temperature exceeds 110 F. For these applications we recommend mixing valve/tempered water (mixing valves are available through your Bradley representative). Product warranties may be found under "Product Information" on our web site at www.bradleycorp.com. 215-1278 Rev. C; EN 03-817 2004 Bradley Corporation Page 1 of 10 6/8/04 P.O. Box 309, Menomonee Falls, WI 53052-0309 Phone: 1-800-BRADLEY Fax: (262) 251-5817 http:\\www.bradleycorp.com

Express Deck Lavatory System EXD Series Installation Instructions - For Service Only Express Deck Dimensions (Standard Height Mounting) 2 6/8/04 Bradley Corporation 215-1278 Rev. C; EN 03-817

Installation Instructions - For Service Only Express Deck Lavatory System EXD Series Installation Instructions Supplies required for installation: (10) 3/8" wall anchors, bolts and washers to mount frame and bowl to wall (minimum pull-out rating of 1,000 lbs.) 1/2" NPT tempered supply piping 1-1/2" NPT drain piping 110 volt electrical outlet for optional 110/24 VAC plug-in transformer for infrared faucet option Step 1: Rough in IMPORTANT: Dimensions in Figure 1a are for a Standard Height Express Deck only. See Figure 1b on page 4 for Juvenile Height Express Deck. 1. Rough in 1/2" NPT hot and cold supply lines through wall at dimensions shown. 2. Rough in 1-1/2" NPT drain waste connection through wall at dimensions shown. 3. Install ten 3/8" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by installer) at the locations shown in Figure 1a below or Figure 1b on page 4. 4. INFRARED FAUCET OPTION ONLY: Install the 110 volt GFCI electrical outlet per local code at the location shown in Figure 1a below or 1b on page 4. Standard Height Mounting - Figure 1a Bradley Corporation 215-1278 Rev. C; EN 03-817 6/8/04 3

Express Deck Lavatory System EXD Series Installation Instructions - For Service Only Juvenile Height Mounting - Figure 1b Figure 2 4 6/8/04 Bradley Corporation 215-1278 Rev. C; EN 03-817

Installation Instructions - For Service Only Express Deck Lavatory System EXD Series Installation Instructions continued... Step 2: Mount frame to wall 1. Remove the nine Torx-head screws securing the panel to the frame and remove the panel (see Figure 3). 2. Position the frame against the wall, ensuring that it is level. IMPORTANT: Anchoring the frame to a wall that is not flat may cause the frame to bend. If necessary, install shims to compensate for any wall distortion. 3. Ensure that the back of the frame is flat against the wall. If wall is not flat, insert shims behind the frame to ensure that it will not bend when anchored. 4. Once you have positioned the frame such that it is level and flat against the wall or shimmed, use the 3/8" bolts and washers to mount the frame to the wall (see Figure 3 below and Figure 4 on page 6). FRAME (10) 3/8" BOLTS AND WASHERS (9) TORX-HEAD SCREW PANEL Figure 3 Bradley Corporation 215-1278 Rev. C; EN 03-817 6/8/04 5

Express Deck Lavatory System EXD Series Installation Instructions - For Service Only Installation Instructions continued... Step 3: Installing bowl assembly NOTE: Refer to Figure 4 below when installing the bowl assembly. IMPORTANT: Moving and positioning the bowl requires more than one person. 1. With someone to assist you, place the bowl assembly squarely onto the frame. 2. Attach the front of the bowl assembly to the frame using the four 1/4"-20 x 3/8" pan-head screws and washers provided. Do not tighten screws at this time. IMPORTANT: When bolting the bowl assembly to the frame and wall, do not overtighten bolts. Overtightening bolts can damage the Terreon material. 3. After the bowl assembly is attached to the frame, use two 3/8" bolts and washers (supplied by the installer) to bolt the bowl to the wall anchors. 4. Tighten the screws installed in procedure #2 above to secure the bowl assembly to the frame. Do not overtighten. Figure 4 6 6/8/04 Bradley Corporation 215-1278 Rev. C; EN 03-817

Installation Instructions - For Service Only Express Deck Lavatory System EXD Series Installation Instructions continued... Step 4: Connecting supply and drain 1. FOR HOT AND COLD SUPPLY: Connect the Vernatherm Thermostatic Mixing Valve as shown in Figure 5a. NOTE: The red marking on Vernatherm Mixing Valve indicates hot water supply inlet. FOR SINGLE TEMPERED SUPPLY: Attach the stop/check/strainer to the 1/2" tempered supply line. Connect the stop/check/strainer to the flexible supply hose (see Figure 5b). FOR INFRARED FAUCET OPTION ONLY: Attach the stop/check/strainer to the 1/2" tempered supply line. Connect the stop/check/strainer to the solenoid valves with the flexible supply hose (see Figure 5b). 2. Install the two drain plugs in the two holes in the bottom of the bowl (see Figure 6). 3. Beneath the bowl, install the 1/4" rubber washers onto the drain plugs, and thread the waste tee to the drain plugs. 4. Assemble the P-trap by connecting the 1-1/2" tubular pipe to the waste tee and to the 1-1/2" drain pipe stubbed out of the wall. 5. Install the strainer on the drain plug opening inside the bowl, and push the strainer firmly into place. TAILPIECE (129-007) NUT (110-005) WASHER (124-001AF) SUPPLIED BY INSTALLER HOT SUPPLY COLD SUPPLY 1/2"-14 NPT Figure 5a 7-5/8" (194mm) STOP/STRAINER CHECK VALVE (S60-003) THERMOSTATIC MIXING VALVE (S01-116) Figure 5b PLUG #8 SCREW BOWL DRAIN PLUG RUBBER WASHER Figure 6 WASTE SHOE WASTE TEE Bradley Corporation 215-1278 Rev. C; EN 03-817 6/8/04 7

Express Deck Lavatory System EXD Series Installation Instructions - For Service Only Installation Instructions continued... Step 5: Completing installation 1. Install the faucets according to the installation instructions that came with your faucets. 2. Turn on the water supply to the Express Deck and check for leaks. 3. FOR DECKS WITH INFRARED FAUCETS ONLY: Turn on the electrical power to the electrical outlet and pass your hand in front of each faucet s sensor until all the air is purged from the lines and water is flowing smoothly. 4. After testing is complete, reinstall panel to frame. Fasten panel with eight Torx-head screws provided (see Figure 3 on page 5). Cleaning and Maintenance Instructions IMPORTANT: Strong alkaline or acid-based chemicals and cleansers should not be used to clean Terreon. If these chemicals come in contact with the Terreon surface, wipe off the surface immediately and flush with soapy water. Terreon and panel maintenance The bowl is constructed of Terreon, a densified solid surface material composed of an acrylic modified polyester resin. Terreon is resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleaners or fine grit abrasives. The panel is made of an acrylic/abs laminate, and will not chip, peel or flake. With regular cleaning, your Terreon fixture will provide years of dependable service. Cleaning Daily Cleaning: Wipe the surface with a damp cloth and wipe dry. Weekly Cleaning: Wipe the surface with a damp cloth and a household liquid detergent. Stubborn stains can be removed as follows: 1. Using a #7448 Scotch-Brite pad, scrub with an abrasive cleanser such as Ajax, Comet or Soft Scrub and water. 2. Clean thoroughly with soapy water and allow to dry. Scorch Marks: Although Terreon will not burn, a lit cigarette in contact with Terreon could leave a scorch mark. Scorch marks can be removed by buffing with a #7448 Scotch-Brite pad or with an abrasive cleaner. Repair kit: In the unlikely event your Terreon surface becomes damaged, it can easily and expensively be repaired. Contact your Bradley representative to order a repair kit and be sure to specify color when ordering. Panel cleaning IMPORTANT: Do not use abrasive cleansers to clean the panel. Abrasive cleaners can mar the surface. Graffiti/Vandalism: If vandals create markings on the panel, Bradley recommends using Motsenbocker s LIFT OFF to remove ink and spray paint. Remover #3 is for ink and markers, and Remover #4 is for spray paint. Motsenbocker s LIFT OFF can be ordered through Sanitary Maintenance Service Inc. (call 1-800-451-5523 x 425 or visit www.santitarymaintenance.com/product.htm for ordering information). After cleaning with LIFT OFF, give the panel a final thorough cleaning with a liquid tub and tile cleaner to remove soil and maintain the glossy finish. NOTE: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an endorsement, nor does the omission of any brand name cleaner imply its inadequacy. Many products named are regional in distribution and can be found in local supermarkets, department and hardware stores or through your cleaning service. It is emphasized that all products should be used in strict accordance with package instructions. 8 6/8/04 Bradley Corporation 215-1278 Rev. C; EN 03-817

Installation Instructions - For Service Only Express Deck Lavatory System EXD Series Assembly of Components Frame and Panel 90 ELBOW 169-639 STOP/STRAINER CHECK VALVE S60-003 BRASS PIPE NIPPLE 113-006DJ Vernatherm Thermostatic Mixing Valve Assembly TAILPIECE (129-007) NUT (110-005) WASHER (124-001AF) SUPPLIED BY INSTALLER HOT SUPPLY COLD SUPPLY 1/2"-14 NPT 7-5/8" (194mm) STOP/STRAINER CHECK VALVE (S60-003) THERMOSTATIC MIXING VALVE (S01-116) Bradley Corporation 215-1278 Rev. C; EN 03-817 6/8/04 9

Express Deck Lavatory System EXD Series Installation Instructions - For Service Only Vernatherm Mixing Valve Maintenance and Service *Repair kit S45-049 is pre-packaged and includes O-Ring, Flip Ring, Power Element and Spring. Maintenance Instructions 1. Disassemble the Vernatherm Valve as shown, being careful not to damage the power element. Replace the element, if necessary. 2. If necessary, remove the old flip ring and replace with a new ring. NOTE: An old or worn flip ring may cause temperature fluctuation and/or water chatter. 3. Reassemble the power element and valve body. Apply grease to the main valve slide and gently ease into position, rotating so that grease is applied to the flip ring. Do not force the slide as this may push the flip ring from its position. To test, rotate the slide; a slight drag should be felt when correctly installed. 4. Reassemble the valve. Body S73-027 Body (chrome) S73-028 Flip Ring* 125-015 Spring* 135-008 O-Ring* 125-001CH Screw 160-175 Power Element* S27-019 Valve Slide S01-039 Cover 107-261B Service Suggestions When servicing the valve, make sure it is installed in the correct position. The most common error occurs when the valve is installed in the reversed position, that is, the hot line is connected to the cold line and the cold is connected to the hot. NOTE: A red marking indicates the hot side of the valve. The table below lists conditions that occur when the valve is installed correctly, and when it is in the reversed position. IF THEN Valve Position is Hot Supply Cold Supply Valve Delivers Correct Hot Cold Mixed 107 Correct Hot No Water Valve shuts off or drips Correct No Water Cold Valve shuts off or drips Correct Hot Hot Hot Correct Cold Cold Cold Reversed Hot Cold Cold/below 107 Hot/above 107 Reversed Hot No Water Hot Reversed No Water Cold Cold Reversed Hot Hot Hot Reversed Cold Cold Cold 10 6/8/04 Bradley Corporation 215-1278 Rev. C; EN 03-817