User Operation Manual

Similar documents
Application, Installation, Operation & Maintenance Manual

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

Installation, Operating and Maintenance Manual

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Fire Alarm Control Panel. System Maintenance and Log Book

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Intelligent Security & Fire Ltd

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Intelligent Security & Fire Ltd

ZSC100 Gas Detection and Alarm System Controller

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell. doc. MIE-MN-570I rev.008

SFC-200 SERIES LED FIRE ALARM PANEL

SERIES 3000 INTELLIGENT FIRE ALARM CONTROL PANEL ENGINEERING PROGRAMING MANUAL TABLE OF CONTENTS.. 1 INTRODUCTION.. 3 SYSTEM POWER UP.

OPERATION AND INSTALLATION MANUAL

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

909e Series 2/4 Zone Panel. Operating and Configuration. Manual Version V01

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

ID2000. operating manual

CHECKFIRE 110 DETECTION AND ACTUATION SYSTEM

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

Doc. No.: OMPII.DOC Rev. 2 Written By: Raj Patel Checked By: AJC Approved By: JBJ Date: 03/05/05

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Sigma XT. Extinguishant Control Panel. User Manual Man-1091 Issue 03 October 2009 (K11031M2, K11031F2)

Excel-EN Conventional Fire Control Panel

EX8. Instruction Manual: COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 AND EN54 PARTS 2 & 4

TABLE OF CONTENTS TABLE OF CONTENTS 1

SECURIT 700L PLUS ENGINEERING MANUAL

SYSTEM 5000 USER MANUAL

CSP-204 CSP-208 CSP-104 CSP-108

FIRE BRIGADE RESPONSE GUIDE. LoopSense. Fire Alarm Control Panel (AS4428 & AS & 4) Operation & Onsite Programming MAN

Conventional Fire Alarm System 2014 V1.2

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

SECURIT 700L USER MANUAL

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

PREMIER EX8 INSTALLATION MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4 INSTALLATION MANUAL

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Installation Manual Premier 412/816/832. Issue 10

GAS SUPRESSION CONTROL PANEL:

NetworX Series NX-1500E LED Keypad

user manual Document No , Revision 03 November 2015

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax:

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

SECURITY SYSTEM NOTES

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

SECURIT 703 USER MANUAL

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Control/Communicator Installation Manual

Intelligent Security & Fire Ltd

HILLS Series LED Code Pad User Manual

FA-300 Series. LED Fire Alarm Control Panel. User Guide. FA-300 SERIES Fire Alarm Control Panel. FA-300 SERIES Fire Alarm Control Panel

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Fire detection and alarm system Operating instructions

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

Security System. User s Guide for the Text Command Center

USER MANUAL & MAINTENANCE GUIDE OG OO

Fire Alarm Control Panel EN54 2 & Operation & Programming MAN

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

SALES SUPPORT DOCUMENT

NETWORX TM. User manual NX-4

Solution Ultima Series Operators Manual ISSUE 1.00

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

NX-148 LCD CODE PAD TABLE OF CONTENTS

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

Control Panel Engineering and Commissioning Instructions

FIRE ALARM CONTROL PANEL FVC01-08

NetworX NX-8V2. LED Keypad User Manual

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

ORION Mini-Rep INSTALLATION MANUAL

Intelligent Security & Fire Ltd

RP1r-Supra / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel User Manual. HLSI-MN-103I v.06 September 2017

USER MANUAL CEF AP28 CONTROL PANEL

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

Technical Data Sheet

MR-2602 Two Zone Fire Alarm Control Panel

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

SOLO Single Loop Addressable Fire Control Panel

Operating instructions Vigilon panel and Network node Fire detection and alarm system

Precept Marine Control Panel Application Guide

Operation and Maintenance Manual

Control Panel User Guide

Control Panel User Guide

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

EP203. User Manual and. Approved Document No. DFU Rev 1

Menvier Fire System MF9300

Conventional & Twin-wire Fire System

Transcription:

APPROVED BY: JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL User Operation Manual PAGE 1 of 6 1

CONTENTS 1. FIRE - GENERAL... 3 2. FIRE - ZONES 1 OR 2 - AUTOMATIC MODE... 3 3. FIRE - ZONES 1 OR 2 - MANUAL MODE... 3 4. AUTOMATIC OR MANUAL MODE - MANUAL RELEASE... 3 5. EMERGENCY ABORT... 3 6. FAULT INDICATION... 3 7. CIRCUIT DISABLEMENT... 3 8. DISPLAY TEST... 3 9. ROUTINE SYSTEM TEST... 3 10. VISUAL INDICATIONS & USER CONTROLS... 4 10.1 FIRE STATUS INDICATIONS... 4 10.2 COMMON STATUS INDICATIONS... 4 10.3 EXTINGUISHING STATUS INDICATIONS... 5 10.4 USER CONTROLS... 5 Danger This equipment contains hazardous voltages that can cause death, serious personal injury, or equipment damage. This equipment contains no user serviceable parts. Refer all maintenance to suitably qualified personnel. PAGE 2 of 6

NOTE: Rotate the ACCESS CONTROLS key to the ON position in order to operate any of the USER CONTROLS. Remove the Key when the panel is to be left unattended. 1. Fire - General The RED zonal fire LEDs will pulse, the alarms will sound and the internal buzzer will pulse once every second. Locate the source of the fire (an LED will be visible on the detector which has been activated). To silence the alarms, press SILENCE ALARMS. The alarms will silence and the red fire LEDs will change to a steady illumination. If necessary, the alarms can be reactivated by pressing RESOUND ALARMS. When the fire has been extinguished, press FIRE RESET. Should the system have activated for no apparent reason, please note which detector has been activated before pressing the FIRE RESET button; then contact your service engineer. 2. Fire - Zones 1 or 2 - Automatic Mode If a fire is detected on either zone 1 or zone 2, the relevant red zone LEDs will pulse, the alarms will sound and the System Activated LED will pulse. If a fire is detected on both zones 1 & 2, both zone LEDs will pulse, the alarms will sound and the System Activated LED will illuminate steady. In addition: the extinguishing Sounders will pulse and the Seconds to Discharge will show the Extinguishant Release Timer countdown. The Extinguishant Release Timer may be stopped manually by pressing the Timer Hold button on a Status Lamp Unit (the Timer will be reset to the start of the countdown). The extinguishing Sounders will change to a longer pulse period. When the button is released the timer will start running again and the extinguishing Sounders will return to the short pulse. When the Timer ends the Seconds To Discharge display will clear and the Extinguishant will be released. Once the extinguishant has been released the extinguishing sounders will change to a continuous operation. 3. Fire - Zones 1 or 2 - Manual Mode this case the Extinguishant can only be released by operation of manual release. 4. Automatic or Manual Mode - Manual Release If a Manual Release switch is operated, the Manual Release LEDs will pulse, the alarms will sound, and the Seconds to Discharge display will show the Extinguishant Release Timer countdown. The timer can be suspended as described above. The extinguishant will be released after timer ends. 5. Emergency Abort The Extinguishant Release may be aborted at any time by operating the Emergency Abort switch on a Status Lamp Unit. Once aborted, the system must be fully reset by sequential operation of the FIRE RESET & EXTINGUISHING SYSTEM RESET buttons. The latched Abort switch must also be returned to the OFF position. 6. Fault Indication The internal buzzer will pulse once every 3 seconds and the appropriate fault LED(s) will pulse. Call your service engineer immediately. Press SILENCE BUZZER to silence the buzzer. WARNING: This equipment contains dangerous voltages. To prevent electric shock, do not open the panel door. There are no user-serviceable parts inside - for servicing, contact suitably qualified personnel. 7. Circuit Disablement To disable a circuit, press the SELECT ON/OFF button. The SELECT cursor will flash on the FIRE SIGNAL fault LED. Press the SCROLL button to move the cursor to the required circuit fault LED and then press the DISABLE button. To enable a circuit, repeat the above procedure to select the required circuit and press the ENABLE button. Press the SELECT ON/OFF button to cancel the SELECT cursor. 8. Display Test The TEST button should be operated every week as part of the system test routine for checking correct operation of the panel buzzer and all LEDs. Press and release the button to sound the buzzer and illuminate all the LEDs for 5 seconds. The system will behave as outlined for automatic mode with the exception that the System Activated LED will not be illuminated steady and the extinguishant release timer will not be initiated. In 9. Routine System Test This should be carried out in accordance with the recommendations of the local Fire Prevention Officer. Refer to the Logbook. PAGE 3 of 6

10. Visual Indications & User Controls FIRE STATUS FIRE FIRE SIGNAL ZONE 1 ZONE 2 AUX ZONE REMOTE SOUND ALARMS REMOTE CONTROLS FAULT FIRE SOUNDER FAULT/DISABLED USER CONTROLS SILENCE ALARMS FIRE RESET SILENCE BUZZER RESOUND ALARMS EXTINGUISHING SYSTEM RESET (INHIBITED) AUTO & MAN/ MANUAL ONLY EXTINGUISHING STATUS AUTO & MANUAL MANUAL ONLY MANUAL RELEASE ACTIVE SYSTEM ACTIVATED GAS RELEASED GAS RELEASED SIGNAL ACTIVE EMERGENCY ABORT ACTIVE EMERGENCY HOLD ACTIVE CIRCUIT FAULT COMMON STATUS POWER SUPPLY ON GENERAL FAULT POWER SUPPLY FAULT SELECT ON/OFF ENABLE GAS LOW GAS TRAPPED IN MANIFOLD ISOLATION VALVE ABNORMAL ISOLATION VALVE CLOSED MANUAL RELEASE FAULT/DISABLED SYSTEM FAULT SCROLL DISABLE EXTINGUISHING DISABLED EARTH FAULT GAS RELEASED SIGNAL DISABLED FUSE FAILED OFF SHUTDOWN OUTPUTS DISABLED FAULT SIGNAL FAULT/DISABLED SOUNDER TEST ACCESS CONTROLS ON TEST SECONDS TO DISCHARGE 10.1 Fire Status Indications FIRE Two Red LEDs: normally off, pulsing for a fire alarm on zones 1, 2, or Aux Zone. The LEDs are illuminated steady if the general sounders are silenced during the fire alarm. FIRE SIGNAL Red LED: normally off, illuminating steady when the Fire Signal output is active. circuit fault on the Fire Signal output, illuminating steady if the Fire Signal output is disabled. ZONE 1 Red LED: normally off, pulsing if a fire condition is detected on zone 1, illuminating steady when the alarm is accepted (by operation of the Silence Alarms button). circuit fault on Zone 1, illuminating steady if Zone 1 is disabled. ZONE 2 Red LED: normally off, pulsing if a fire condition is detected on zone 2, illuminating steady when the alarm is accepted (by operation of the Silence Alarms button). circuit fault on Zone 2, illuminating steady if Zone 2 is disabled. AUX ZONE Red LED: normally off, pulsing if a fire condition is detected on the Aux Zone, illuminating steady when the alarm is accepted (by operation of the Silence Alarms button). circuit fault on the Aux Zone, illuminated steady if the Aux Zone is disabled. REMOTE SOUND ALARMS Red LED: normally off, illuminating steady when the Remote Controls input registers a Sound Alarms. circuit fault on the Remote Controls input. FIRE SOUNDER FAULT/DISABLED circuit on either of the general sounder circuits, illuminating steady when the general sounder circuits are disabled. 10.2 Common Status Indications POWER SUPPLY ON Green LED: illuminated steady as long as there is a supply of power to the panel. GENERAL FAULT Yellow LED: normally OFF, pulsing for any fault on the panel. POWER SUPPLY FAULT Yellow LED: normally OFF, pulsing if there is a mains or battery failure. SYSTEM FAULT Yellow LED: normally OFF, steady if the microprocessor fails to execute the software correctly or an internal memory corruption is detected. Note: The system is completely non-functional when in system fault. Alternative arrangements for fire detection must be made. EARTH FAULT Yellow LED: normally OFF, pulsing if there is a low impedance to earth on any of the field cables. PAGE 4 of 6

FUSE FAILED Yellow LED: normally OFF, pulsing if either of the electronic fuses on the two auxiliary 24V supply outputs activate due to excessive loading. FAULT SIGNAL FAULT/DISABLED circuit fault on the Fault Signal output, illuminating steady if the Fault Signal output is disabled. SOUNDER TEST Yellow LED: normally off, illuminating steady when the three sounder circuits are in the TEST mode. 10.3 Extinguishing Status Indications AUTO & MANUAL Yellow LED: illuminated steady if the actuators can be operated both automatically (via a fire alarm on zones 1 & 2) and manually (via manual release). MANUAL ONLY Yellow LED: illuminated steady if the actuators can only be operated manually (via manual release), pulsing if an AUTO/MANUAL switch in the field is set to Manual MANUAL RELEASE ACTIVE Red LED: normally off, pulsing if manual release is activated, illuminating steady when the alarm is accepted (by operation of the Silence Alarms button when not inhibited). SYSTEM ACTIVATED Red LED: normally OFF, pulsing during the preactivated condition, illuminating steady during the activated condition. GAS RELEASED Red LED: normally OFF, illuminating steady when the extinguishing gas is released. GAS RELEASED SIGNAL ACTIVE Red LED: normally off, illuminating steady when the Gas Released output is active. EMERGENCY ABORT ACTIVE Yellow LED: normally OFF, pulsing if a fault occurs on the Abort input while the Extinguishing System is not in the pre-activated or activated state, illuminating steady if the emergency Abort switch on a Status Lamp Unit is activated, or a fault occurs on the input during the preactivated or activated state. EMERGENCY HOLD ACTIVE Yellow LED: normally OFF, pulsing if the Hold button on a Status Lamp Unit is pressed when the pre-discharge delay timer is not running, illuminating steady If the Hold button is pressed or a fault occurs on the input while the pre-discharge delay timer is running. CIRCUIT FAULT Yellow LED: normally OFF, pulsing when any of the circuits related to the Extinguishing system has a fault. GAS LOW Yellow LED: normally OFF, pulsing when the quantity of extinguishing gas in the bottles is too low. GAS TRAPPED IN MANIFOLD Yellow LED: normally OFF, pulsing when the gas fails to exit from the manifold. ISOLATION VALVE ABNORMAL Yellow LED: normally OFF, pulsing when the Isolation valve is stuck between open & closed positions. ISOLATION VALVE CLOSED Yellow LED: normally OFF, pulsing when the Isolation Valve is fully closed. MANUAL RELEASE FAULT/DISABLED Yellow LED: normally OFF, pulsing if the Manual Release zone input is in fault or the internal circuit to the door mounted Manual Release is in fault, illuminating steady when the Manual Release facility is disabled. EXTINGUISHING DISABLED Yellow LED: normally OFF, illuminating steady when the extinguishing gas release facility is disabled. GAS RELEASED SIGNAL DISABLED Yellow LED: normally OFF, illuminating steady when the Gas Released Signal output is disabled. SHUTDOWN OUTPUTS DISABLED Yellow LED: normally OFF, illuminating steady when the 1 st Stage, 2 nd Stage & 3 rd Stage shutdown outputs are disabled. SECONDS TO DISCHARGE Red 2-digit numeric display: normally off. When the predischarge timer is running, the remaining seconds left to discharge are shown. 10.4 User Controls All buttons except for TEST (for Test Display) are disabled until the ACCESS CONTROLS key-switch is rotated to the ON position. SILENCE ALARMS Silences the general sounders and/or the extinguishing sounders (unless inhibited). Yellow LED: normally OFF, pulsing when it is possible to silence any of the sounder circuits, illuminating steady when sounder circuits have been silenced. RESOUND ALARMS Causes previously silenced sounders to be resounded. FIRE RESET Resets fault and fire indications on the Fire Alarm section of the panel. Faults common to the Fire section & the Extinguishing section are also reset. EXTINGUISHING RESET When not inhibited, resets fault and active indications on the Extinguishing section of the panel. Faults common to the Fire section & the Extinguishing section are also reset. Yellow LED: normally off, illuminating steady when the Extinguishing System Reset is inhibited. SILENCE BUZZER Silences the internal buzzer during any fault or alarm condition. Yellow LED: normally off, illuminating steady when the buzzer has been silenced. AUTO & MANUAL / MANUAL ONLY Toggles the panel status between Automatic & Manual and Manual Only modes. SELECT ON/OFF Toggles the Circuit Select Cursor ON and OFF. ENABLE Valid only while the Circuit Select Cursor is ON. Restores the selected circuit to normal operation (cancels test & disabled states). DISABLE PAGE 5 of 6

Valid only while the Circuit Select Cursor is ON. Disables the selected circuit. TEST Circuit Select Cursor OFF: Operates the Test Display feature, sounding the internal buzzer and illuminating all the LEDs on the Display for five seconds. Circuit Select Cursor ON: Places the selected circuit into test mode. SCROLL Valid only while the Circuit Select Cursor is ON. Moves the Circuit Select cursor through the available circuit LEDs. Note: All zone disable/enable operations result in the zone power supply being disconnected for 10 seconds. PAGE 6 of 6