Residential Eligible Improvements and Guidelines FLORIDA To qualify for Ygrene funding, all project improvements must meet or exceed applicable local, state and federal codes and standards, and be installed by Ygrene Certified contractors or participating property owners in accordance with manufacturer recommendations. PRODUCT TYPE REQUIRED CONTRACT DETAIL PRICING GUIDELINES MAX TERMS (YEARS)* Alternative Energy Advanced Energy Storage Systems N/A $1.00/kwh 10 Co-generation System N/A Call Electric Vehicle Charging Station Power supply: 110V, $2,500 10 2, Direct DC Fuel Cell Power System, Stationary PACE Power output < 40 kw $15,000/kW 10 output Standby Generator 1 kw, Fuel Type $1,500/kW Wind Turbine Power output (kw) $45,000/system Building Envelope Air Sealing % Reduction $11,250 Electrical Panel Upgrade TBD $7,500/ea * Electrical Wiring Modernization N/A $15/sf * Energy Efficient Reflective Coating Solar reflectance > 0.5 $12/sf Insulation, Attic R-value > 38 $8.00/sf * Insulating Carpet & Padding R-value > 2 $10 10 Insulation, Hot Water Pipe Linear feet Call * R-value > 3.0 Insulation, Siding R-value >1 $18.75/sf Insulation, Under Floor $8/sf * Insulation, Under Slab $14/sf * Insulation, Wall Type: batts (open wall), blown-in R-value > 13 batts: $10/sf blown-in: $13/sf * 1 Must be attached to the property. 2 Prescriptive (indicate which applies): Solar Reflectance (must be greater than 0.15); Thermal Emittance (must be greater than 0.7); CRRC Product ID. 3 Performance (indicate which applies): Provides min 1" airspace between roof deck and roofing; insulates attic to minimum R-38; seals and insulates attic ducts; provides radiant barrier; provide min R-4 roof deck insulation *Exception of 25 years for Flood Zone X
Radiant Barrier Reflectivity > 0.9 Emittance < 0.1 $8.00/sf Roof Installation (roof) Prescriptive 2 Performance 3 Weather Stripping # Windows # Doors Heating, Ventilation, Air Conditioning (HVAC) Air Conditioner, Central w/zone Control Central HVAC >= 14 Size (ton) Air Conditioner, Mini-Split Cooling capacity (kbtu) built-up: $15/sf * membrane PV: $15/sf modified bitumen:$15/sf metal: $15/sf asphalt shingle: $15/sf applied coating: $15/sf concrete tile: $/sf clay tile: $.65/sf wood shake bare: $10/sf polyurethane (closed cell): $/sf $100/ea $5,000 $28,2 <9 kbtu: $6,000 >9-14 kbtu: $6,300 >14-22 kbtu: $6,500 >22 kbtu: $,0 Air Conditioner, Packaged Terminal (PTAC) N/A $3,000 Biomass/Pellet Wood Stove N/A $15,000 Ceiling Fan # Fans $1,000/ea Duct Replacement # Ducts $2,500/ea * Duct Sealing Linear feet $3.00/lf Energy Efficient Air Purifier (built-in) N/A $5,000 Energy Efficient Gas Boiler System N/A $22,000 * Evaporative Cooler N/A $5,000 Fan, Whole House N/A $6,000 Furnace Type: electric, gas Heating capacity (kbtu) Heat Pump, Condensing Component Heat Pump, Geothermal Energy use (EER) Coefficient of Performance (COP) Hydronic Radiant Heating System Efficiency Size (kbtu) Ventilator, Heat/Energy Recovery Efficiency >.82 Size (CFM) Ventilator Fixture, Exhaust # Zones Size (CFM) $12,000 $12,000 15 $7,765 $37,000 $5,000 * $1,000 * 18 Ygrene Energy Fund. All rights reserved. June 14, 18
Ventilation Fixture, Attic Size (CFM) $2,500 * High-Efficiency Water Heating Hot Water System Controller N/A $1,500 15 Smart Recirculating Hot Water System N/A $4,000 Water Heater, Storage Type: electric, gas Storage size (Gal) Efficiency 30 Gal electric: $8,500 gas: $8,500 >30-50 Gal electric: $8,500 gas: $8,500 >50-75 Gal electric: $8,500 gas: $8,500 >75 Gal electric: $11,500 gas: $11,500 Water Heater, Tankless Energy factor > 0.9 (Energy factor x Btu/hr) x Max Btu/hr 0.08 High-Efficiency Lighting, Appliances Energy Efficient Appliances N/A Call (Affixed to property) LED Lighting Fixture, Indoor # New fixtures New: $900/ea Replacement: # Replacement fixtures $400/ea LED Lighting Fixture, Outdoor # New fixtures $1,000/ea Lighting Control System N/A $4,500 High-Efficiency Pool Equipment Automatic Pool Cover N/A $7,000 Electric Heat Pump Pool Heater N/A $10,500 Gas Pool Heater N/A $10,000 Pool Pump and Motor Pump/motor size (HP) $6,500 Solar Photovoltaic Solar PV System (Must include panel upgrade; roof repairs associated with system) # Solar panels Panel size (W) Inverter type: string, micro, w/optimizers # Inverters Inverter size (W) $4.00/watt Solar Thermal Solar Pool Heating N/A $10,000 Solar Water Heating Type: evacuated tube, $15,000 plastic collector Solar Water Treatment System N/A $8,000 10 Windows, Doors, Skylights Additional building openings to provide natural light Awning, Exterior 18 Ygrene Energy Fund. All rights reserved. June 14, 18 15 * N/A Call * Type: fabric, metal Fabric: $1,000/ea # Awnings Metal: $4,000/ea Awning, Retractable Exterior # Awnings $9,000 10 10 (fabric) (metal) Door, Energy Efficient Exterior # Standard doors Standard: $3,000/ea * # Custom doors Custom: $15,000/ea Glass Doors French # Doors $7,500/ea * Glass Doors Sliding # Standard doors Standard: $4,000/ea * # Custom doors Custom: $15,000/ea Light Tubes N/A $2,500 * Patio Covers $60/sq ft Shutter, Exterior # Shutters $1,500 Skylights # Skylights $3,000 * Windows # Windows $2,500/ea *
Window Film # Windows $285/window 10 Window & Door Blinds, Interior # Interior blinds $1,500 Window & Door Shutters, Interior # Shutters $2,000 Wind Resistant Measures Cable Hold-downs N/A Call Foundation Strengthening N/A Call * Gable-end Bracing N/A Call High-impact Doors # Doors Standard: $5,000/ea * Custom: $15,000/ea Glass Doors - Sliding # Doors $7,500/ea High-impact Windows # Windows $4,000/ea Opening Protections/Garage Doors # openings $10,000/ea Roof Deck Attachment Strengthening N/A Call Roof-to-wall Reinforcement N/A Call Sea Walls N/A Call Secondary Water Barrier N/A Call Sill Plate Attachment Strengthening N/A Call Storm Shutters # Openings Call Type: storm panel, accordion, colonial, bahama, rolldown, hurricane glass Waterproofing - Basement Membrane $/sf Wind Resistant Roofing asphalt shingles: $15/sf modified bitumen:$15/sf membrane/tpo: $15/sf applied coating/foam: $15/sf metal roof: $15/sf clay/concrete tile: $/sf built up roof: $15/sf wood shake: $15/sf polyurethane (closed cell): $/sf * 18 Ygrene Energy Fund. All rights reserved. June 14, 18
Commercial Eligible Commercial Improvements and Guidelines FLORIDA To qualify for Ygrene funding, all project improvements must meet or exceed applicable local, state and federal codes and standards, and be installed by Ygrene Certified contractors or participating property owners in accordance with manufacturer recommendations. PRODUCT TYPE REQUIRED CONTRACT DETAIL MAX TERMS (YEARS) Alternative Energy Advanced Energy Storage Systems N/A 10 Co-generation System N/A Electric Vehicle Charging Station Power supply: 110V, 2, Direct DC 10 Fuel Cell Power System, Stationary PACE Power output < 40 kw output 10 Fuel Cell Power System, Backup Power output (kw) 10 Standby Generator 1 kw, Fuel Type Wind Turbine Power output (kw) Building Envelope Air Sealing % Reduction Building Control Systems N/A Commercial Kitchen Exhaust Air Volume N/A Control Systems Electrical Panel Upgrade TBD * Electrical Wiring Modernization N/A * Elevator Motors and Controls N/A Energy Efficient Reflective Coating Solar reflectance > 0.5 Green Roof (roof) Type: extensive, intensive Industrial Process Equipment Motors and Controls N/A Insulation, Attic R-value > 38 * Insulation, Hot Water Pipe Linear feet * R-value > 3.0 Insulation, Siding R-value >1 Insulation, Under Slab * Insulation, Under Floor * Insulation, Wall Type: batts (open wall), blown-in * R-value > 13 Radiant Barrier Reflectivity > 0.9 Emittance < 0.1 Roof Installation (roof) * Prescriptive 2 Performance 3 SMART Parking Lot Fixtures N/A SMART Parking Garage Fixtures N/A 1 Must be attached to the property. 2 Prescriptive (indicate which applies): Solar Reflectance (must be greater than 0.15); Thermal Emittance (must be greater than 0.7); CRRC Product ID. 3 Performance (indicate which applies): Provides min 1" airspace between roof deck and roofing; insulates attic to minimum R-38; seals and insulates attic ducts; provides radiant barrier; provide min R-4 roof deck insulation. *Exception of 25 years for Flood Zone X
SMART Wall Pack Fixtures N/A Weather Stripping # Windows # Doors Heating, Ventilation, Air Conditioning (HVAC) Central HVAC 14 Air Conditioner, Central w/zone Control Air Conditioner, Mini-Split Cooling capacity (kbtu) Air Conditioner, Packaged Terminal (PTAC) N/A Biomass/Pellet Wood Stove N/A Ceiling Fan # Fans Cooling Condensate Reuse Projects N/A Cooling Towers N/A Cooling Tower Controllers N/A Duct Replacement # Ducts * Duct Sealing Linear feet Energy Efficient Air Purifier (built-in) N/A Energy Efficient Gas Boiler System N/A * Evaporative Cooler N/A Fan, Whole House N/A Furnace Type: electric, gas Heating capacity (kbtu) Heat Pump, Condensing Component 15 Heat Pump, Geothermal Energy use (EER) Coefficient of Performance (COP) HVAC Zoning Control Systems N/A Hydronic Radiant Heating System Efficiency Size (kbtu) Ventilator, Heat/Energy Recovery Efficiency >.82 * Size (CFM) Ventilator Fixture, Exhaust # Zones * Size (CFM) Ventilation Fixture, Attic Size (CFM) * High-Efficiency Water Heating Hot Water System Controller N/A 15 Smart Recirculating Hot Water System N/A Water Heater, Storage Type: electric, gas 15 Storage size (Gal) Efficiency Water Heater, Tankless Energy factor > 0.9 Max Btu/hr High-Efficiency Lighting, Appliances Energy Efficient Appliances N/A (Affixed to property) High Efficiency Lighting N/A LED Lighting Fixture, Indoor # New fixtures # Replacement fixtures LED Lighting Fixture, Outdoor # New fixtures Lighting Control Systems N/A Refrigeration Case Lighting Including Sensors Occupancy N/A 18 Ygrene Energy Fund. All rights reserved. June 14, 18
SMART Project Pathway Lighting N/A Task Ambient Lighting Projects N/A Wireless Lighting Controls N/A High-Efficiency Pool Equipment Automatic Pool Cover N/A Electric Heat Pump Pool Heater N/A Gas Pool Heater N/A Pool Pump and Motor Pump/motor size (HP) Indoor Water Efficiency Deionization Equipment N/A Pre-rinse Spray Valves N/A Outdoor Water Efficiency AG Irrigation Pumps and Controls N/A Industrial Process Water Reuse Projects N/A Recycled Water Source Projects N/A Solar Photovoltaic Solar PV System (Must include panel upgrade; roof repairs associated with system) # Solar panels Panel size (W) Inverter type: string, micro, w/optimizers # Inverters Inverter size (W) Solar Thermal Solar Pool Heating N/A Solar Water Heating Type: evacuated tube, plastic collector Solar Water Treatment System N/A 10 Windows, Doors, Skylights Additional building openings to provide natural light N/A * Awning, Exterior Type: fabric, metal 10 (fabric) # Awnings (metal) Awning, Retractable Exterior # Awnings 10 Door, Energy Efficient Exterior # Standard doors * # Custom doors Glass Doors French # Doors * Glass Doors Sliding # Standard doors * # Custom doors Light Tubes N/A * Patio Covers Shutter, Exterior # Shutters Skylights # Skylights * Windows # Windows * Window Film # Windows 10 Window & Door Blinds, Interior # Interior blinds Window & Door Shutters, Interior # Shutters Wind Resistant Measures Cable Hold-downs N/A Foundation Strengthening N/A * Gable-end Bracing N/A High-impact Doors # Doors * High-impact Sliding Glass Door # Doors High-impact Windows # Windows * 18 Ygrene Energy Fund. All rights reserved. June 14, 18
Opening Protections/Garage Doors # openings Roof Deck Attachment Strengthening N/A Roof-to-wall Reinforcement N/A Sea Walls N/A Secondary Water Barrier N/A Sill Plate Attachment Strengthening N/A Storm Shutters # Openings Type: storm panel, accordion, colonial, bahama, rolldown, hurricane glass Waterproofing - Basement Membrane Wind Resistant Roofing * Green-Energy-Products.com jnovar@green-energy-products.com Cell 305.251.9630 Fax 786.242.8929 18 Ygrene Energy Fund. All rights reserved. June 14, 18