CLEANROOM MONITOR CR3A Network - Installation Instructions

Similar documents
Analog Room Pressure Monitor RPC Series

Carbon Monoxide Transmitter

Two-Channel Gas Controller

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Carbon Monoxide Transmitter

Temperature Controllers

Combustible Gas Detection and Control System

Oxygen (O2) Single-Point Gas Detection System

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

I/O ZONE 560/583 USERS GUIDE

Product Manual SZ1144

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual

OVEN INDUSTRIES, INC.

Product Manual SZ1145

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Networkable Fan Coil Controller Specification and Installation Instructions

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

RS485 MODBUS Module 8AI

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Process & TeMPerATUre UniversAl input DigiTAl MeTers

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

MO n : 12JMC rév A

Series Temperature Controller Instruction Sheet

RPM1600 Series Room Pressure Monitors

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

PTE0705 Electric Fence Monitor

Installation Manual Tracker 221

CTT8 TEMPERATURE MONITOR DEVICE

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

ARO Series. Description. Features. Modbus CO2 VOC. Networkable* ARO AROB24TGVH AROB24TGH. room controller. (AROB series only) or network

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

Pioneer-R16 Gas Monitor Operator s Manual

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

Danfoss gas detection units

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

B-40/B-41 Modulating Temperature Controller

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Introduction. What is the W2W Open controller?

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

Bacnet Room Setpoint & Temp Display. Descriptions. Specifications

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Table of Contents SECTION PAGE

Series A3 and A4 Differential Pressure Controller

Multiview Monitor / Controller

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Instruction Bulletin

02/11/2015

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

INSTALLATION INSTRUCTIONS

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

JDDT1 - Single Stage Digital Thermostat

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

Danfoss gas detection units

Accuracy by Design Products for the HVAC Professional

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Multi-Gas-Controller MGC2

Lift Station Level Controller

02/11/2015

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Oakton TEMP 9500 Advanced Multiparameter Controller

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Independent Zone Control (I.Z.C.)

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

ExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet

INSTALLATION & USER MANUAL

EXD-HP1/2 Stand-alone Superheat/Economizer Controller

N1540 Process Indicator

ExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

XWA11V. Walk-In Temp / Door /Alarm / Light Module

Beck. The differential pressure transmitter for air

RTD-10 Installation Instructions

Duct and Rough Service Carbon Monoxide Sensor

Series RSM Room Status Monitor. Specifications - Installation and Operating Instructions 5-13/32 [137.16] 8 [203.20] 4-5/8 [117.

Table of Contents. WSHP Open v3

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Series Digital Controller Instruction Sheet

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

P2267 NETWORK INTERFACE

Ammonia Leak Detector Manual

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

DAP III Zone Master User s Guide

Product Manual SZ1009

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide. SE8600 Series Room Controllers

General Specifications

Alarm Output None. Code 5 N Y N R2 R3 A AC/DC100~240V. 2 Relays 3 Relays R4 4 Relays O2 2 Open Collect O3 3 Open Collect O4 4 Open Collect

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers

Pump-Up Controller MODEL 4062

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

Transcription:

CLEANROOM MONITOR CR3A Network - Installation Instructions INTRODUCTION The CR3 Series Cleanroom Monitor, was developed specifically to allow for monitoring of confined spaces with accuracy and reliability. The CR3 allows for either in-room or remote monitoring with three different models; integrated sensors, remote sensors or display only to suit a variety of installation needs. It features a flush fitting stainless-steel front plate that enables the user to wipedown the unit when necessary. BEFORE INSTALLATION Read these instructions carefully before installing and commissioning the cleanroom monitor. Failure to follow these instructions may result in product damage. Do not use in an explosive or hazardous environment, with combustible or flammable gases, as a safety or emergency stop device or in any other application where failure of the product could result in personal injury. Take electrostatic discharge precautions during installation and do not exceed the device ratings. MOUNTING STEP 1 - As illustrated in Figure 1, unscrew four screws from faceplate, set screws aside, and remove faceplate from mounting bracket. Cut hole in wall 21 mm x 167 mm high. Ensure unit can be secured to wall stud or equivalent on at least two sides. 21 mm 167 mm Figure 1 STEP 2 - As illustrated in Figure 2, feed wires through mounting bracket and conduit connector/cable gland and secure. STEP3 - As illustrated in Figure 3, insert mountain bracket into hole in wall. Figure 2 Figure 3 Page 1

Figure 4 Figure 5 Figure 6 Figure 7 STEP 4 - As illustrated in Figure 4, insert screws (not included) to secure mounting bracket to studs. (Minimum #8 screw) STEP 5 - Remove connectors from packaging box. As illustrated in Figure 5, connect wires to wiring terminals. Refer to wiring section for terminal identification. STEP 6 - Match wiring terminals to the labels on the back cover and re-insert the wiring terminals into the unit. As illustrated in figure 6. Figure 8 STEP 7 - As illustrated in Figure 7, run poly tubing onto the pressure port that is mounted on the rear or faceplate. Connect poly tube to customer supplied pressure vent (i.e. Greystone RPV). STEP 8 - As illustrated in Figure 8, secure faceplate to mounting bracket with supplied screws. Route wires and tubing to prevent pinching when installing unit into wall mounting bracket. WIRING Deactivate the 24 Vac/dc power supply until all connections are made to the device to prevent electrical shock or equipment damage. Follow proper electrostatic discharge (ESD) handling procedures when installing the device or equipment damage may occur. Use 22 AWG wiring for all connections and do not locate the device wires in the same conduit with wiring used to supply inductive loads such as motors. Make all connections in accordance with national and local codes. Connect the 24 Vac/dc power supply to the terminals labeled +(power) and - (common) as shown in Figure 9. This device has a half-wave type power supply so use caution when wiring multiple devices so that the circuit ground point is the same on all devices and the controller. Use caution if 24 Vac power is used and one side of the transformer is earth-grounded. In general, the transformer should NOT be connected to earth ground when using devices with RS-485 network connections. The device is reverse voltage protected and will not operate if connected backwards. Figure 11shows network connections. For end of Line (EOL) device place termination resister jumper in ON position, for all other devices, place jumper in OFF position. Page 2

Figure 9 REAR VIEW Common (24Vac) +24Vdc (24Vac) Communications Shield Communications () Communications () Digital Input (-) Digital Input (+) VIN OMMS DIG IN - + S - + COMMS ALARM CONTACTS RH- RH+ TE- TE+ DP - DP+ RH- RHV RHI TE- TEV TEI DP - DPV DPI SENSOR BOARD ALARM CONTACTS ANALOG OUTPUTS Pressure Analog Output (4-2mA) Pressure Analog Output (-5Vdc or -1Vdc) Pressure Analog Output (Ground) Temperature Analog Output (4-2mA) Temperature Analog Output (-5Vdc or -1Vdc) Temperature Analog Output (Ground) Humidity Analog Output (4-2mA) Humidity Analog Output (-5Vdc or -1Vdc) Humidity Analog Output (Ground) Pressure Relay (+) Pressure Relay (-) Temperature Relay (+) Temperature Relay (-) Humidity Relay (+) Humidity Relay (-) Figure 11 COMMUNICATION WIRING Device 1 Device 2 Device 3 Building Controller 24 Vdc Common Shield COM SHLD COM SHLD COM SHLD Jumper Location Connect Shield One End Only ON OFF External 24 Vdc Power Supply or 24 Vac Transformer Set EOL Jumper Building Controller Device 1 Device 2 Device 3 Common COM COM COM Shield SHLD SHLD SHLD Connect Shield One End Only Figure 12 DIG IN COMMS 1 2 1 2 1 2 3 ALARM CONTACTS 1 2 3 4 5 6 ANALOG OUTPUTS 1 2 3 4 5 6 7 8 9 24 VDC / 24 VAC (+) COMMON / 24 VAC (-) DI + DI - A - B + SHIELD (S) Pressure (+) Pressure (-) TEMPERATURE (+) TEMPERATURE (-) HUMIDITY (+) HUMIDITY (-) DP 4-2mA (DPI) DP -5/1VDC (DPV) DP COMMON (DP-) TE 4-2mA (TEI) TE -5/1VDC (TEV) TE COMMON (TE-) RH 4-2mA (RHI) RH -5/1VDC (RHV) ANALOG OUTPUTS RH COMMON (RH-) CONNECTORS (Front view, screw on top) Page 3

ALARM RELAYS The device has three alarm relay outputs. The outputs are Normally Open and will close when an alarm event occurs. The alarm outputs are assigned to TEMP, RH and DP. Each alarm can be set to operate as a low alarm, a high alarm, both low and high alarms or be disabled. For example: The TEMP Alarm output can be configured as a high alarm by setting TEMP Alarm Operation to High Alarm. In this case the alarm condition will be set when the temperature exceeds the TEMP Alarm High Setpoint. Note that alarm hysteresis and alarm on delay will also come into play, described below. The RH Alarm output can be configured as both low and high alarms by setting RH Alarm Operation to Both. In this case the alarm condition will be set when the RH goes above the RH Alarm High Setpoint or below the RH Alarm Low Setpoint. If any ALARM OPERATION is set to Disable, then that alarm will have no function and the setpoints will be hidden on the menu. Each alarm has a hysteresis value and an on delay time associated with it. For high alarms, the alarm condition is set when the input value exceeds the high setpoint and it is reset when the input value goes below the setpoint hysteresis value. For example, if the TEMP ALARM HIGH SETPOINT = 25. C and TEMP ALARM HYSTERESIS =.5 C, then the alarm condition will set at 25. C and reset at 24.5 C. The hysteresis is opposite for TEMP ALARM LOW SETPOINT. The alarm condition will set when the input value falls below TEMP ALARM LOW SETPOINT and will reset when the input goes above TEMP ALARM LOW SETPOINT + HYSTERESIS. Each alarm also has a configurable on delay. When an alarm condition is set a timer is started and the actual alarm will not get set until the ALARM ON DELAY time has expired. If the alarm condition gets reset before the time expires, then no alarm is generated. All three alarm relays operate as self-resetting and non-latching. The input signal must return to nonalarm condition before the alarm relay returns to the NO state. ALARM SETPOINTS Each process variable (TEMP, RH and DP) has both a high and low alarm setpoint. If the alarms are enabled and the setpoint is not locked, then the user can change the setpoint values within a range. ALARM LEDS The TEMP, RH and DP each have a low and high alarm condition. When any alarm condition is set the corresponding front panel LED will flash. The alarm LEDs mimic the alarm relays. If any alarm is disabled, then the LED will be disabled also. BUZZER ALARM The buzzer alarm can be assigned to any of the TEMP, RH or DP alarms specifically, or it can be assigned to all of them. It can be disabled via BUZZER ASSIGNMENT. If assigned, the buzzer will activate whenever the associated alarm(s) are triggered. The buzzer reset can be configured as either manual only or automatic reset with BUZZER RESET. In manual mode the buzzer can only be silenced by: removing the alarm condition or by pressing the front panel <SILENCE> key In automatic reset mode the buzzer can be silenced by: removing the alarm condition or by pressing the front panel <SILENCE> key or automatically when the BUZZER AUTO RESET TIME expires The buzzer is reset or silenced as described above but the alarm condition will continue to be set, this function only silences the buzzer. If the alarm condition is reset and then set again, the buzzer will activate again. The buzzer provides a beeping or chirping sound, not a continuous tone. Page 4

DIGITAL INPUT The digital input signal allows detection of a dry-contact type input change. This input could be connected to a door switch, remote nurse station silence switch, occupancy sensor etc. The actual program function of the DI can be set with DIGITAL INPUT FUNCTION. The input may be disabled to have no internal program function, or it may be used as a remote alarm silence with the same function as the front panel <SILENCE> key, or it may be used as a door freeze function. The door freeze function can be used to prevent alarms and fast ramps of the analog output when a door is opened. In this mode, if a digital input from a door switch is detected, then the operation of the device freezes. This means that no alarms will be generated and the analog outputs are held at the last value before the door open occurred. The device will sit in this state until the door closes again. There is a small delay of 1 seconds to allow the room to stabilize again after the door is closed. RS-485 NETWORK The network connection is a standard feature on the product and is necessary to fully configure the device. The unit will have either BACnet or Modbus protocol implemented. ANALOG OUTPUTS There are three analog output signals to represent TEMP, RH and DP. Select desired output via installer menu for current (4-2 ma) or voltage output signals. If the analog outputs are set for voltage output, then the signal type can be set to either -5 Vdc or -1 Vdc via the Installer Menu. All outputs will set for the same type. The direction of the analog output signals may be reversed by using the TEMP OUT DIRECTION (for example) Installer Menu item. This means that the output signal will be 5- V or 2-4 ma instead of -5 V or 4-2 ma. MIN MAX VALUES The program maintains the minimum and maximum value of each sensor value. The values may be displayed via the User Menu and may also be reset via the User Menu. MISCELLANEOUS The displays (and associated alarm LEDs) for each process variable may be turned off if necessary using the Installer Menu items such as TEMP DISPLAY. Display brightness may be changed from high to low using DISPLAY BRIGHTNESS via the User Menu. Page 5

OPERATION Start up When power is first applied to the device, a specific sequence of events occurs to test the displays plus indicate certain parameters. The sequence is as follows: Test all LEDs all LEDs light for 2 seconds and then turn off Test all display segments all display segments light for 2 seconds and then turn off Display version # - display 1. on one of the displays for 2 seconds Display selected protocol display Prot bac or Prot bus Display address - display Addr 3 Display baud rate - display baud 96 Buzzer beeps 2 times Begin normal operation FRONT PANEL KEYS There are 4 front panel buttons: <UP> <DOWN> Used to increase parameter values within a menu. Used to decrease parameter values within a menu. <MENU> In normal operation, pressing this button accesses the User Menu and then is used to step through the menu items. The button is disabled if USER MENU LOCK is set. <SILENCE> Used to silence the buzzer if it is active. INSTALLER MENU The Installer Menu is accessed by pressing and pushing both the <UP> and <DOWN> buttons together in normal operation at the same time for 5 seconds. This menu is used in the field to configure parameters such as the communication protocol, device address, analog output type, etc. The Installer Menu may be locked so it cannot be accessed in the field, or unlocked via BACnet, Modbus or the Factory menu if necessary using INSTALLER MENU LOCK. If the Installer Menu is unlocked, then the following parameters are available to be changed. Some items will not be available depending on other settings. NOTE : To change a previous setting, return to the initial install menu. 1. Baud Rate b a u d 9 6 9 6, 19 2, 38 4, 57 6, 76 8, 115 2 a d d r 2. Address b a c -127 for BACnet Addr 3 1-255 for Modbus to 255 Page 6

INSTALLER MENU (Continued) Only if Modbus selected 3. Parity (No Parity, Odd or Even) P a r n o n non, odd, E (Default = non) 4. Stop Bits s t o p 1 1 or 2 (Default = 1) 5. CRC a 1 A1, 121, 85, 848 (Default = A1) c r C 6. Delay d e l y, 5, 15, 2, 25, 3, 35 (Default = ) 7. Analog Output Type curr, volt (Default = curr) c u r r (Current or Voltage) o u t 8. Volt Output Scale (Only if voltage selected) V o l t o u t 5 5 or 1 (Default = 5) Only if AO OVERRIDE set via comms 9. AO TEMP Override 1. AO RH Override 11. AO DP Override a o 1 t e a o 2 r h a o 3 d p to 1 (Default = ) to 1 (Default = ) to 1 (Default = ) Page 7

INSTALLER MENU (Continued) 12. DP Auto Zero (Only if DP within 1% range) 13. User Menu (Lock / Unlock) d p C a l U s E R u n l o c cal, lo, hi, pas (Default = cal) unloc, Loc (Default = unloc) USER MENU The User Menu is accessed by pressing the <MENU> key. This menu is used in the field to configure parameters such as alarm setpoints. The User Menu may be locked so it cannot be accessed in the field, but can be unlocked via BACnet, Modbus or the Installer menu if necessary using USER MENU LOCK. If the User Menu is unlocked, then the following parameters are available to be changed. If SETPOINT LOCK is set, then the setpoints can be viewed but not changed. 1. Temperature Units 2. Pressure Units (Pascal or mmwc) 3. Display Brightness u n i t t e c u n i t d p p a d s p y b r t h i C F (Default = C) PA, StA (Default = PA) hi, Lo (Default = hi) 4. TEMP Alarm Low Setpoint t e s p (Resolution is 1 via the menu) l o (-26 C or 32 to 79 F) 5. TEMP Alarm High Setpoint t e s p (Resolution is 1 via the menu) h i 2 2 1 (4-3 C or 39 to 86 F) 6. RH Alarm Low Setpoint r h s p (Resolution is 1 %RH via the menu l o 5 to 6% RH 7. RH Alarm High Setpoint r h s p (Resolution is 1 %RH via the menu) h i 3 6 5 4 to 9% RH Page 8

8. DP Alarm Low Setpoint d p s p (Resolutionis 1 Pa or 1 mmwc via men) When Pa units selected, setpoint value displayed has been divided by 1. -25 to Pa (-25 to mmwc) Pressure Range 1-5 to Pa (-5 to mmwc) Pressure Range 2 9. DP Alarm High Setpoint d p s p (Resolution is 1 Pa or 1 mmwc via menu) When Pa units selected, setpoint value displayed has been divided by 1. l o h i -15 to 2 Pa (-15 to 2 mmwc) Pressure Range 1-4 to 4 Pa (-4 to 4 mmwc) Pressure Range 2 1. TEMP Minimum Value t e l (Resolution is.1 C) (displays minimum recorded temperature) 11. TEMP Maximum Value t e h i (Resolution is.1 C) (displays maximum recorded temperature) 12. RH Minimum Value r h l (Resolution is 1%RH) (displays minimum recorded RH) 13. RH Maximum Value r h h i (Resolution is 1%RH) (displays maximum recorded RH) 2 2 4 9 2 5 2 1 2 7 1 3 1 14. DP Minimum Value d p l o (Resolution is 1 Pa or 1 mmwc) (displays minimum recorded differential pressure) 15. DP Maximum Value d p h i (Resolution is 1 Pa or 1 mmwc) (displays maximum recorded differential pressure) 16. Min Max Reset h i (Pressing <SILENCE> resets the min max values) l o r s t (Press <Menu> to exit menu and retain min/max values) Note that only the setpoints that are configured will be shown. For example, if TEMP ALARM OPERATION is set for High Alarm only, then the TEMP Alarm Low Setpoint will not be shown. Note that the setpoint resolution is limited when setting with the menu, but higher resolution is available via the network. Page 9

SPECIFICATIONS GENERAL Operating Conditions Storage Temperature Power Supply Power Consumption Wiring Connections Pressure Connections - 5 C (32-122 F), - 9 %RH non-condensing -2-6 C (-4-14 F) 24-3 Vdc / 2-26 Vac 2 ma max Pluggable screw terminal block (14 to 22 AWG) Port for 1/8 ID tubing Enclosure - Wall Mount: SS34, suitable for wipe-down. 225mm wide x 182.5mm high x 36mm deep. (8.86 x 7.19 x 1.46 ) Weight 1.3 kg Certification CE, RoHS TEMPERATURE Sensor Type 1KΩ NTC thermistor sensor Temperature Range -5 C, 32-122 F Accuracy ±.2 C (±.4 F) curve matched RELATIVE HUMIDITY Sensor Type Thermoset polymer based capacitive sensor RH Range -1 %RH Accuracy ± 2 %RH Hysteresis ± 1.5 %RH Stability ± 1.2 %RH typical @ 5 %RH in 5 years DIFFERENTIAL PRESSURE INPUT (CRA, CRB MODELS): Sensor Type MEMS piezo resistive differential sensor Pressure Ranges 1 ± 25 Pa or ± 25 mmwc 2 ± 5 Pa or ± 5 mmwc Accuracy ±.5 %FS Stability ±.5 %FS max (1 year) Thermal Effect < ± 1 %FS, - 7 C (32-158 F) Proof Pressure 24.9 kpa (249 mmwc) Burst Pressure 74.7 kpa (747 mmwc) Media Compatibility Dry air or inert gas INDICATION Temperature Display 3 digit LED as.-5. C or 32.-122 F ( C / F is indicated by an LED) Relative Humidity Display 3 digit LED as.-99.9 %RH Differential Pressure Display 3 1/2 digit LED display as -5-5 Pa or -5.-5. mmwc (Pa / mmwc is indicated by an LED) Digit Type 7 segment red LED,.8 (2.32 mm) high Alarm Indication Low/High alarm red LED for each USER INPUT Programming Alarm Silence ANALOG OUTPUTS Signal Type Number of Outputs Output Drive Output Scales Menu / Up / Down front panel tactile keys Silence front panel tactile key 4-2 ma (sourcing) and -5 Vdc / -1 Vdc selectable 3 (Temp, RH, DP) 5 Ω max for 4-2 ma, 1 KΩ min for voltage -5 C, -1 %RH, ± 5 Pa ALARM OUTPUTS Number of Outputs 3 (Temp, RH, DP) can assign condition as low/high/both Output Type NO optically isolated solid state FET switch Contact Rating 1 ma at 28 Vac / 4 Vdc maximum Trip Point Upper and Lower alarms adjustable over a range Alarm Delay to 255 seconds (programmable) Operation Self-resetting, non-latching Alarm Buzzer Internal, operates on any alarm condition Buzzer Delay -255 seconds (programmable) Buzzer DB 7db at 3cm Operation Self-resetting, can be silenced via key or disabled remotely COMMUNICATION Hardware Isolated 2-wire RS-485 MS/TP Software Modbus RTU or BACnet Baud Rate 96, 192, 384, 576, 768 or 1152 Address Range 1-255 for Modbus, -127 for BACnet DIMENSIONS 225 mm 8.86 36mm 1.46 182.5 mm 7.19 Page 1

NETWORK SETUP GUIDE The network set up guide describes the implementation of the BACnet or Modbus protocol. It is intended to assist control system programmers who may need to add support to their systems to communicate with this device. BACnet and Modbus setup guide downloads are available online. BACNET PROTOCOL http://downloads.greystoneenergy.com/sg/sg-cr3-bacnet-1.pdf MODBUS PROTOCOL http://downloads.greystoneenergy.com/sg/sg-cr3-modbus-1.pdf Page 11

Page 12