Lifting Station Type ABS Sanimax

Similar documents
ABS lifting station Sanimax

Submersible Grinder Pump Type ABS Piranha S10 - PE125

Submersible Grinder Pump Type ABS Piranha S10 - PE125

Installation, Operating and Maintenance Instructions

Submersible Sewage Pump Type ABS XFP 80C - 201G

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

Trusted Expertise in Domestic and Commercial Wastewater

INSTRUCTIONS AND WARRANTY

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

Manual / Handbuch Spare parts list / Ersatzteilliste

INSTRUCTIONS AND WARRANTY

FAVORIT34502VIO. EN User Manual

Waste water ejection unit

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

TTB582PMP Barcode: Ref. No.: 55753

GUH90 90 cm Canopy Hood

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

INSTRUCTIONS AND WARRANTY

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

INSTALLATION AND OPERATING INSTRUCTIONS

KESSEL Grease separator EasyClean free Standard, Direct - oval in NS 2, 4, 7, 10, 15, 20, 25, 30 for set-up in frost-free rooms

BLOW DRY & GO HAIR KIT

ABS submersible sewage pump XFP 80C - 201G

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

GETTING STARTED? EASY.

Lifting Plants Product Overview

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

500 SERIES FOOD WASTE DISPOSERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR 523 SERIES SERIES SERIES 17

MW401 Integrated Dishwasher

EN Bagged Vacuum Cleaner

2 IN 1 JUICER AND BLENDER

Sanipack is a compact pump/macerator specially designed to take the waste from a wall hung or back to wall WC pan.

1.5L Fryer v1.0. Model: SD6060N. Helpline. SD6060N_IM.indd 1 07/10/ :58

Lo-Carbon Quadra Centrifugal Fan

Manual for installation, use and maintenance MW200. Integrated Slimline Dishwasher. year. parts + 1 year labour guarantee.

SP-RANGE INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR SP12 & SP25 SERIES 4

Kettle User Manual WKD6306W WKD6306B EN 01M M

INSTRUCTIONS AND WARRANTY

AEM EASY DRUM M A N U A L

SUBMERSIBLE DIRTY WATER PUMP

Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers

INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS

Zen Boiling Tap Range

MW402 Integrated Dishwasher

Designed in the UK. Rapide. User Guide V-024E. Performance is everything. vax.co.uk

GUH52SD 52 cm GUH75 75 cm Canopy Hood

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

SAFETY AND OPERATING MANUAL. Original Instructions 5.0

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

V80-H Multistage Pump Instruction Manual

CE Unit is suitable for material transport. The transported gas may be up to 80 C.

Kettle User Manual WKM6306W WKM6306B EN 01M M

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR CARE GIFT SET MODEL C85003

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

2 KW OIL FILLED RADIATOR

INSTRUCTIONS AND WARRANTY

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

Designed in the UK. Rapide Ultimate. User Guide Vax Rapide Ultimate

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

FHA 1100 A1 Domestic Water Pump

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

T550i power shower pump Installation and operating instructions

CTA15-2 warming drawer. operating and installation instructions

ESL 5201LO EN DISHWASHER USER MANUAL

Safety and Instruction Manual

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

User Manual Dishwasher FAVORIT 56302MO FAVORIT 56302WO

Rapide Deluxe PT. User Guide V-026PTS. Performance is everything. vax.co.uk

User Manual. 600mm, 700mm & 900mm Gas Cooktops Model No. CF6GS, CF6GW, CF7GS, CF9GS

Instructions for Operation and Maintenance of Containers

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

Contents. Dryer description, 4 The front The back Control panel

AQUA PREMIER ELECTRONIC ELECTRIC SHOWER. Installation and User Guide

1. Description. 2. List of Accessories included

WC600 Integrated Dishwasher Installation, Use and Maintenance

Bar Fridge USER MANUAL MB46W

Greenleaf 600 Macerator Toilet Waste Pump

How to get the most from your Integrated Tumble Dryer HJA 8800

Instructions for Use Warming Drawer. Bedienungsanweisung Wärmeschublade. Notice d'utilisation Chauffe-vaisselle. Gebruiksaanwijzing Servieswarmer

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

GETTING STARTED? EASY.

Operating Instructions

INSTRUCTIONS AND WARRANTY

Instruction Manual for Electric Warming Drawer BWD14B

BarAid 400. Installation and. Starting from Serial No.:

HX-30/40 and HX-30/40 S Glass and Dishwashers

Autotrol Performa FA Valve

Domestic Hot Water Tank

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

Glue Gun 25W TTB580HTL. Barcode: WARNING: Read the instructions before using the product!

Singulier Spout Tube Basin Mixer Installation and User Guide

Your Blast Vac Pro. Your Blast Vac Pro

CoCo LoCo BLOW & GO NUTS DRYER. LSHD24 Instruction Manual

CONTENTS SAFETY INFORMATION. Electrical connection 6. Safety information 1. Environmental concerns. Customer service and spare parts

Rise. Digital. Bath with overflow filler. Rise Digital Bath installation instuctions page 1

ASSEMBLY & OPERATING INSTRUCTIONS

MIX Boiler & Font Range Service Manual

User Manual. Spend a little Live a lot. TABLE TOP COOLER

Transcription:

1051-00 15970278EN (11/2015) EN Installation and Operating Instructions www.sulzer.com

2 Installation and Operating Instructions (Original Instructions) : R 202 MF 154 R 202/C MF 154HW MF 324 Contents 1 General... 3 1.1 Application areas... 3 1.2 Nameplate... 4 1.3 Summary of the legal regulations covering the use of lifting stations for the pumping of faecal-free effluent... 4 2 Safety... 4 3 Transport... 4 4 Description... 5 4.1 Design of the lifting unit... 5 5 Installation... 6 5.1 Cable inlet... 6 5.2 Discharge Line... 6 5.2.1 Installation example Sanimax R202 and R202/C... 7 5.3 Electrical connection... 7 5.4 Washing machine connection... 8 5.5 Hand wash basin connection... 8 5.6 Shower connection (only used with Sanimax R202 & R202/C)...8 6 Maintenance... 9 6.1 General maintenance hints... 9 6.2 Cleaning the lifting unit... 9 Sulzer reserves the right to alter specifications due to technical developments

Installation and Operating Instructions (Original Instructions) 3 1 General 1.1 Application areas ATTENTION The maximum allowable temperature of the medium pumped: Sanimax R 202 & R 202C, Sanimax MF 154 & 324 = 40 C Sanimax MF 154HW = 80 C The Sanimax with Sulzer submersible pump has been designed for the dewatering of buildings below the sewer level. It is suitable for faecal-free effluent in accordance with EN 12056/DIN 1986-100. The Sanimax is a compact wastewater lifting unit which can be installed under or beside the wastewater source at floor level. m In accordance with the regulations for effluent lifting stations, pumping of effluent containing faecal matter, or the pumping of flammable or explosive fluids, is not allowed with these lifting stations. Examples of substances that should not be allowed into the tank: Aggressive fluids such as acids, lyes (caustic soda) or salts. Flammable liquids such as petrol, oil or phenols. Commercial and agricultural waste. Solid substances such as ash, rubbish, glass, sand, fibrous material, cardboard, paper towels, textiles, diapers, kitchen waste, coffee grounds, shredder waste. Liquid substances that can harden, such as bitumen, cement, lime, lime milk (whitewash), mortar, potato starch, grease (edible oils and fats), synthetic resin, synthetic resin emulsion, tar, paint residues. Cleaning agents, disinfectants. Abrasive material. ATTENTION As with all electrical devices, this product may fail due to operating errors, absence of mains voltage, or even a technical defect. Such a failure may result in medium or water escaping. If damage may occur due to the specific usage, measures are required to avoid such damage arising. In this respect, taking account of the conditions in question, particularly use of an off-grid alarm system, use of an emergency generator, and provision of an additional and appropriately connected second unit are to be considered. Sanimax R 202 & R 202C, Sanimax MF 154 & 324 m This product is only suitable for removing clear and dirty water up to a water temperature of 40 C or up to a maximum of 60 C during short-term operation. If the system is fed water from units such as washing machines, then the maximum water temperature could be exceeded if the device is not equipped with discharge cooling or if this is not switched on, e.g. in order to save energy. This may cause damage to the pump or the pumping system. In such case Sulzer will not accept any guarantee or warranty claim. If necessary, contact the manufacturer of the device or devices provided for connection (e.g. washing machines) to obtain information on how to switch on discharge cooling. If not possible then we recommend installation of the Sanimax MF 154HW model (see below). Our systems are checked in accordance with EN 12050 LGA and conform to the current standards. Also note that the maximum inlet temperature to the public sewer system is 35 C and that you must ensure that the water is cooled accordingly. Sanimax MF 154HW Sanimax MF 154HW is designed for the pumping of high temperature liquids up to a maximum of 80 C. m All inflow and discharge pipework to the unit must be temperature resistant accordingly and is the responsibility of the customer.

4 Installation and Operating Instructions (Original Instructions) 1.2 Nameplate We recommend that you record the data from the nameplate on the pump in the form below, and maintain it as a source of reference for the ordering of spare parts, repeat orders and general queries. Always state the pump type, item number and serial number in the field Nr/SN in all communications. Made in Ireland Figure 1: Nameplate Sulzer Pump Solutions Ireland Ltd. Wexford, Ireland www.sulzer.com 68 Legend Type Pump type Nr Item number SN Serial number xx/xxxx Production date (Week/Year) U Rated voltage V Rated current A Hz Frequency Hz P1 Rated input power kw 1/min Speed r/min Qmax Max. flow m 3 /h Hmax Max. head m Max. submersible depth m 1.3 Summary of the legal regulations covering the use of lifting stations for the pumping of faecal-free effluent. Automatically operated lifting units are prescribed if: the water level in the odour lock lies below the sewer backwash level. rainwater gullies from areas below the sewer backwash level are present. The sewer backwash level is the maximum possible water level in the public sewer network. Information on this can be obtained from your Local Authority. If the backwash level has not been fixed by the Local Authority, then the surface level of the roadway at the connection point is taken to be the level. If the effluent does not give rise to foul odours, then a water-tight connection tank fitted with a lid is acceptable. 1052-02 ATTENTION! The Regulations of DIN 1986 as well as your own local by-laws should be observed. 2 Safety The general and specific health and safety guidelines are described in detail in the Safety Instructions for Sulzer Products Type ABS booklet. If anything is not clear or you have any questions as to safety make certain to contact the manufacturer Sulzer. This unit can be used by children aged 8 years and above, and persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, when they have been given supervision or instruction concerning the safe use of the device and understand the hazards involved. Children must not play with the appliance. Cleaning and user maintenance should not be performed by children without supervision. 3 Transport ATTENTION! The lifting unit should not be thrown or dropped during transport. c The Sanimax unit should not be lifted by the cable! m All relevant safety regulations as well as good general technical practice must be complied with.

Installation and Operating Instructions (Original Instructions) 5 4 Description Five optional connections for inflow line or cable already prepared for installation, as well as two discharge connections for PVC pipe. Hose connection nozzle ¾. Odour-tight cover containing vent with odour filter and overflow protection. Non-return valve fitted as standard. A supplementary checkvalve is required above 5 m head (MF 154HW = 3 m). 4.1 Design of the lifting unit 1 2 5 6 1053-01 1 2 5 6 1054-01 7 7 3 4 3 4 Figure 2: Sanimax R202 & R202/C Figure 3: Sanimax MF 1 Discharge line 5 Vertical inflow in tank cover 2 Non-return valve 6 Tank venting with integral odour filter and overflow protection 3 Synthetic tank (triangular shape) 7 Sealed cable entry 4 Wastewater pump with level control Supplied as standard: Sanimax R202 & R202/C Sanimax MF Washing machine connection adapter Washing machine connection adapter Hose clamps Hose clamps Discharge line connection adapter with non-return valve fitted Discharge line connection adapter with non-return valve fitted Rubber elbow Flexible discharge pipe PVC discharge pipe PVC discharge pipe with elbow (stainless steel when fitted with MF 154HW pump)

6 Installation and Operating Instructions (Original Instructions) 5 Installation NOTE: EN, DIN, and VDE regulations should be observed 5.1 Cable inlet Remove cable ties and select tank opening. Remove external stopper (5) from the tank opening while leaving the tank seal (2) in place. Feed cable (3), with cable stopper (1) and cable seal (4), to the outside of the tank. Lubricate tank seal. Insert cable stopper fully into seal. Internal External 1 2 3 1055-01 Tie up the residual cable in the tank with the aid of a cable tie and place securely between pump and tank wall at the opposite side to the level control system. The cable should not hinder the movement of the float. 4 5 Figure 4: Cable inlet (1) Cable stopper (2) Tank seal (3) Cable (4) Cable seal (5) External stopper 5.2 Discharge Line As shown in the installation example below, the discharge line outer diameter 40 mm should be brought above the backwash loop (180 bend) and then allowed to flow by gravity into the collection sewer or channel (regulations EN 12056 and DIN 1986/100). The discharge line should be laid so that it is not affected by frost. The discharge line should not be connected to a downpipe. No other discharge lines or inflows should be connected to the discharge line. Select a suitable tank port for the discharge line and remove the plug. If necessary, rotate the rubber bend to suit. The discharge line inside the tank should be inserted (at least 30 mm) into the rubber bend. Tighten the hose clamps thoroughly. For further details see pump installation sheet (MF 15975136 and Robusta 15975137) supplied with the unit. All other tank openings can be used in a similar manner. The non-return valve fitted into the rubber discharge line connection adapter, must be installed in such a manner that the non-return valve opens in the flow direction. Ensure that the flap is orientated so that the hinge is at the highest point.

Installation and Operating Instructions (Original Instructions) 7 5.2.1 Installation example Sanimax R202 and R202/C 10 1) 7 9 2 3 1 11 4 8 6 5 12 Figure 5: Installation example 1 Synthetic tank 2 Wastewater pump Robusta 202 with TS level control system 3 Bend 4 Cover with integral odour lock 5 Variable inlet possibiiities. Pipes Ø 40/50 mm 6 Discharge line connection with seal and non-return valve 7 Earthed socket 8 Discharge line 40 mm 9 Sealed cable entry 10 Hose connection for washing machine 11 Shut-off valve (accessory) 12 Backwash loop 1) Install backwash loop so that the lower edge is above the backwash level. 1056-01 5.3 Electrical connection c Before operating, have a qualified person check that all required electrical protective measures are present. Earthing, neutral line, earth leakage circuit breakers, etc. must correspond to the regulations of your local Electricity Supply Provider and must function perfectly. ATTENTION! Cross-section and voltage drop of the power line must correspond with the local Electricity Supply Board regulations. ATTENTION! Check that the voltage on the nameplate of the pump is the same as the mains voltage. The unit is fitted with a float switch, which automatically switches on and off the pump at the pre-set switching heights. c The earthed socket should, depending on type fitted, be installed at the prescribed distance from the lifting station and water source.

8 Installation and Operating Instructions (Original Instructions) 5.4 Washing machine connection The washing machine nozzle should be installed together with seal from the inside and pushed into the washing machine hose. 1057-00 ATTENTION! Clamp the washing machine hose with a hose clamp. 5.5 Hand wash basin connection Figure 6: Washing machine connection For hand wash basin connection, remove the plug in the cover and push the S-bend tube downward into the unit. Connect the S-bend to the hand wash basin. Do not fully tighten the plastic nuts. Determine the tube length (allow approximately 20 mm of the tube to enter the unit), cut to size and carry out final assembly. 1058-00 Figure 7: Hand wash basin connection 5.6 Shower connection (only used with Sanimax R202 & R202/C) When connecting a shower, one of the lower tank ports should be used. The height difference between the floor of the shower and the floor of the tank of the lifting unit should be to EN/DIN in accordance with the illustration. In the case of a greater distance between the Sanimax R202 & R202/C and the shower basin, it is necessary to make an addition to allow for the recommended fall for gravity flow. The shower basin must then be located at a higher level. 1059-00 Figure 8: Shower connection Before closing the tank lid, carry out a test run. This is done by allowing water to flow into the tank and observing the functioning of the pump switching heights. Sanimax R202 & R202/C: ON = 85 mm; OFF = 55 mm approx. Sanimax MF: ON = 225 mm; OFF = 50 mm approx. In order to ensure that it is correctly sealed, the tank cover, with the pipe inlet to the back, is placed in position and pressed until all four moulded securing clips are fully engaged.

Installation and Operating Instructions (Original Instructions) 9 6 Maintenance c Before carrying out any maintenance work on the unit, all power lines should be disconnected from the mains, and care should be taken that the unit cannot be inadvertently switched back on. c To avoid danger if the power cable is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualifed person. Servicing must only be carried out by qualified personnel. ATTENTION! The maintenance hints given here have not been provided for DIY repair work as special technical knowledge is required. The Sulzer warranty is only valid if original Sulzer spare parts have been used for all repair work. 6.1 General maintenance hints Sulzer lifting units are reliable products of proven quality and are subject to careful testing before leaving the factory. Lubricated-for-life ball bearings together with monitoring devices ensure optimum reliability of the pump, provided that installation and usage is in accordance with our operating instructions. Should a problem arise, do not improvise but ask your Sulzer Service Centre for assistance. In order to ensure a long running life, regular checks and care are recommended. The Sulzer Service Organisation will be glad to advise you on any special applications you have, and is always ready to assist you with your pumping problems. 6.2 Cleaning the lifting unit The lifting unit should be cleaned at least once a year. If the unit is lightly soiled, it should be rinsed out a number of times with clean water. If the unit is heavily soiled, then it is necessary to remove the submersible pump for cleaning. ATTENTION! This work should only be carried out by a Sulzer Service Centre or Contract Workshop. A maintenance contract with one of our factory authorised Service Centres will ensure the best possible professional maintenance for all events.

10 Installation and Operating Instructions (Original Instructions)

Installation and Operating Instructions (Original Instructions) 11

Sulzer Pump Solutions Ireland Ltd. Clonard Road, Wexford, Ireland Tel. +353 53 91 63 200 Fax +353 53 91 42335. www.sulzer.com