MODEL MP-1S OVERSPEED UNIT

Similar documents
VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

VM-5 SERIES MONITOR INSTRUCTION MANUAL

VM-5 SERIES MONITOR. MODEL VM-5P3 Phase Marker Unit INSTRUCTION MANUAL

VM-15 SERIES MONITOR. Model VM-15U1 VELOCITY MONITOR INSTRUCTION MANUAL

VM-5 SERIES MONITOR MODEL VM-55 VIBRATION MONITOR INSTRUCTION MANUAL

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

VM-15 SERIES MONITOR INSTRUCTION MANUAL

4TEMPERATURE CONTROLLER

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

DTM Distributed Transmitter-Monitor

Sentry G3 Machinery Protection Monitor

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

Sentry G3 Machinery Protection Monitor

AUR300C. Advanced Ultraviolet Burner Controller

SHIMADEN DIGITAL INDICATORS

Temperature Controllers

02/11/2015

3. Compatible Sensor Wiring 4. Batch Contact Wiring See section 9 for simple and advanced mode configuration options.

Advanced Ultraviolet Burner Controller

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

02/11/2015

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

7EF/7HF/7EC/7ES Temperature Controllers

Speed and Frequency Seite 1 von 7

TEMPERATURE CONTROLLER

Ramsey Motion Monitoring Systems

INSTALLATION INSTRUCTIONS EA SERIES DOOR PROP/EXIT ALARM

AO Annunciator Module

PS914 Power Supply. 900-KL Keylock (optional) Page BB Battery Backup (optional) Page 3

- Data Brochure Boiler Control 274

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

CLEANROOM MONITOR CR3A Network - Installation Instructions

DB5 Intrinsically Safe Sounder Type DB-5

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

MICRO CONTROLLER S Z SERIES

Installation Manual Tracker 221

FUNCTIONAL SAFETY MANUAL

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller

DIGITAL METERS Large Display Temperature Meters Instruction Manual

c0094 form 2. Project Identification Year: 2001 Project nº: 910

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA

condition monitoring WP4086 Condition Monitoring System The WP4086 CMS System surveys vibrations with up to 8 external accelerometers

General Specifications

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller

Code 2. A AC/DC 100~240V N None

SAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .

WP4086 Condition Monitoring System

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

Z24 Wireless Zone Controller Professional Installation Guide

R Air flows from high pressure side to low pressure side. This principle can be applied to keep clean-air in the room or, alternatively, not to leak p

ELECTRONIC HUMIDISTAT: H270

Power Controller THV-A1 Series

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Digital Heater Element Burnout Detector K8AC-H

ELECTRONIC HUMIDISTAT: H200

I/A Series 716C 1/16 DIN Temperature Controller

STANDARD. Customer : DC FAN. Description : Customer P/N : rev. : N/A X01. Sample issue date : DEC Quantity :

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

M2500 Engine Controller Installation Manual

Danfoss gas detection unit Type GD Heavy Duty

3500/61E & 3500/67E Temperature Monitor

Universal controller for panel mounting Models CS6S, CS6H, CS6L

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

Technical Data. Dimensions

D5100 Industrial Differential Pressure Transducer

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Refrigerant Leak Detector Manual

ANEMOMETER 4403-RF-BAT

M5800 Pressure Transducer with Rotatable Display

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

DSD-3 DIFFERENTIAL SPEED DETECTOR

Part 3 Troubleshooting

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Process Alarm Module RTA 421

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER

M7100 Pressure Transducer

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Laser Collimated Beam Sensor

Analog Room Pressure Monitor RPC Series

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Tachometer/Hourmeter/Trip. Installation and Operation Manual

REFRIGERATED BATH CIRCULATOR. Instruction Manual. Covers model : LRBC-13C / LRBC-22C. Please read this manual carefully before using the instrument

Nov 08 PRODUCT SPECIFICATION SHEET

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

MODEL: 47NLVT. Digital Panel Meters 47NL Series. POWER INPUT DC Power R: 24 V DC

Gas leak detection system. for heating rooms and similar environments. Description. Sensor for methane gas IP44. Sensor for LPG gas IP44

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Installation & Operation Manual

User s Manual YTA610 and YTA710 NEPSI Certification

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

INSTALLATION/OPERATING INSTRUCTIONS SEQUENCING PANELS

Transcription:

MODEL MP-S OVERSPEED UNIT SPEIFIATIONS Model Spec. ode upon delivery/add l Spec. ode( not requested, leave blank ) MP-S- - - - Hysteresis Set up Monitor Range Input Signal No. of Input Pulse Trigger Mode (Shaped Waveform circuit) 2 to 2,000 rpm RD, FK Series 0 4 to 20m AD to 255 pulse / no. of revolutions Auto 0.5V 0 Not provided 3 to 4,000 rpm 2 MS Series to 5 VD Ex.) =00 2 Manual 2.0V Provided 4 to 5,000 rpm H5 Series 3 2.0V 3 Note: In case MS is input, Short-circuited Detection is not possible. 5 to 0,000 rpm (AIRPAX o.) In case H5 Series is input, Input Abnormality detection is not possible. 6 to 5,000 rpm 7 to 20,000 rpm - - - Alarm Reset Alarm Reset Alarm Reset START-UP TIMER Function System Group* (TRP) (ALT) (NOT-OK) (TRP) (ALT) (NOT-OK) 0 Not provided 0 Auto-Reset 0 Auto-Reset 0 Auto-Reset 0 Normally De-energized 0 Normally De-energized 0 Normally De-energized A Provided Self-Hold Self-Hold Self-Hold Normally Energized Normally Energized Normally Energized 2 B 3! Warning Note) * hose the same group code on each unit used for a system as This unit should not be used for the purpose of controlling the system, because the response of "2 out of 3" or "2 out of 2" in a same rack. the is slow. should be used for the purpose of data recording.! Danger In case the Overspeed Protection System is designed to be used with this unit, use the redundant system consisting of three units (corresponding to 2 out of 3). For highest reliability, use other meters or machinery protection equipment to design the system. In case the machine protection is performed using a single meter, and that meter is experiencing a problem, it may cause severe injury or damage to the equipment. Input No. of Revolutions In case the Indicated No. of Revolutions differs from the Input Overspeed Set Point 2 points (TRP, ALT) / Indicated No. of No. of Revolutions, fill in the numbers below. Overspeed Set Range an be setup in rpm increments up to 000rpm to 00% of Revolutions When the Input No. of Revolutions is rpm, monitor range. Ratio hange rpm. Overspeed Set Accuracy ± rpm or less (Not Standard In case the magnification is or more, the accuracy resolution ABNOR. Alarm Output point (NOT-OK) Specifications) becomes worse in proportion to the magnification number. Rotation Measured LED Digital meter with 5 digits (7 segments) hangeable Range: 0.00 (Indicated No. of Revolutions / Input No. of Revolutions) 9.999 Value Overspeed Setup Value TRP : ALT : Trigger Indicator TRG. : (Red LED) However, TRP ALT. If unspecified, 50% of delivered monitor range. Shift Key Select Indicator SHIFT : (Red LED) Overspeed Relay Hysteresis an be setup within the range 0 to 50 rpm ( rpm Increments) TRP : Input RD, FK Series, MS Series, H5 Series (AIRPAX o.) ALT : Input Impedance About 5 kω If unspecified, 0 rpm when delivered. Input Voltage Range 300 Vpk-pk or less an be setup within the range 5 to 50% of F.S.(5% Increments) Min. Input Pulse Width 5 µs Setup value : Min. Indicated frequency 0 Hz Dimension(Model RD,FK) No. of Input Pulses to 255 pulse D B A D A D B External ontact Input ontact Type : Dry contact ontact for External Reset ontact for Lamp Test ontact for START-UP Timer ontact for TRP Alarm BYPASS Note: A should not be flat. Make the curve along a concentric circle. A= mm B= mm = mm D= mm Input RD-05A FK-202F A 6 B 7 2.5 (mm) D 6 Dimension of Target Recommended Set Gap Setup Value(mm).0 to.5 Digital Indicated Accuracy onversion Accuracy Pulse Output ±(0.003% of rdg. + digit) at 25 ±(0.03% of rdg. + digit) at 0 to 60 Voltage or current output proportional to monitor range. to 5VD (Output Impedance : 250Ω) 4 to 20mAD (Max. Load Resistance : 600Ω) Number of Output Point : point ±0.5% of F.S. at 25 ±2.0% of F.S. at 0 to 60 Pulse Output : Shaped pulse signal is output via a buffer amplifier. Signal Level : - to +V(P L ), +4 to 6V(P H ) Output Impedance : About 00Ω -24VD±V, 20mA (RD,FK specified) +2VD±V, 50mA (H5 specified) (Provided 9V to 27 VD s from the bass-line in the Alarm ontact Output Output Point : TRP : 2 points Instrument Rack) : ALT : 2 point Temperature Range Operating Temperature : 0 to 60 : NOT-OK : point Storage Temperature : -30 to +85 ontact apacity : Resistance Load : 250VA, 5 A Relative Humidity : 20 to 95%RH (noncondensing) : 30VD, 5A Face Plate Finish Munsell N-.0 (equiv.) ontact Type : ontact, Dry ontact Mass Max. 2.0kg Response Time : 30 ms at 300Hz or more E Marking onform to E requirements when MP-P2 is used for power supply unit. ondition TRP ontact ALT ontact Not-OK ontact Indication After PU Abnormality Detection 0 V (0mA) Input abnormal Detection Input Abnormal Indication 0 V (0mA) TRP Information Sent TRP Indication Measured Value ALT Information Sent ALT Indication Measured Value On-line Test (ontact Output Mode) On-line Test Indication Test Value On-line Test (ontact ontrol Mode) On-line Test Indication Test Value Unit Removal All ontacts Open All ontacts Open All ontacts Open 0 V (0mA) : Information Sent : Output ontrol : No relation ship 39803E.9 Revised : Dec.2009

MP- Series Monitor Specifications MODEL MP-Z ZEROSPEED UNIT Model Spec. ode upon delivery / Add l Spec. ode ( not requested, leave blank ) MP-Z- - - Hysteresis Set up Input Signal No. of Input Pulse* (shaped Waveform circuit) RD, FK Series 0 4 to 20mAD to 20 pulse / no. of revolutions 0.5V 0 Not Provided H5 Series to 5VD Ex.)=00 2.0V 3 Periods of Zerospeed setup value 2 (AIRPAX o.) 3 2.0V 2 5 Periods of Zerospeed setup value Note: In case H5Serise is input, Input Abnormality detection is not possible. - - Note) * 20 P/R or more is recommended. *2 hose the same group code on each unit used for a system as "2 out of 3" or "2 out of 2" in a same rack. Alarm Reset Alarm Reset Alarm Reset (Z) (Z2) (NOT-OK) (Z) (Z2) (NOT-OK) System Group*2 0 Auto-Reset 0 Auto-Reset 0 Auto-Reset 0 Normally De-energized 0 Normally De-energized 0 Normally De-energized A Self-Hold Self-Hold Self-Hold Normally Energized Normally Energized Normally Energized 2 B 3! Warning This unit should not be used for the purpose of controlling the system, because the response of the is slow. should be used for the purpose of data recording. In case the Zerospeed system is designed to be used with this unit, for the safety and reliability of the turning gear apparatus, use s redundant system consisting of 3 units (corresponding to 2 out of 3). For the highest reliability, it is recommended to design the system with other fast shut-down conditions. Input No. of Revolutions In case the Indicated No. of Revolutions differs from the Input Zerospeed Set Point 2 points (Z, Z2) / Indicated No. of No. of Revolutions, fill in the numbers below. Zerospeed Set Range an be setup in 0. rpm increments within the range 0.0rpm Revolutions When the Input No. of Revolutions is rpm, to 99.99rpm. Ratio hange rpm. Zerospeed Set Accuracy ± 0.0rpm or less (Not Standard In case the magnification is or more, the accuracy resolution ABNOR. Alarm Output point (NOT-OK) Specifications) becomes worse in proportion to the magnification number. Rotation Measured LED Digital meter with 5 digits (7 segments) hangeable Range: 0.00 (Indicated No. of Revolutions / Input No. of Revolutions) 9.999 Value Zerospeed Setup Value Z : Z2 : Trigger Indicator TRG. : (Red LED) However, the following conditions must be satisfied. Z Z2 Shift Key Select Indicator SHIFT : (Red LED) 0.0rpm Z,Z2 99.99rpm 0.6/Nrpm Z,Z2 N: No.of Input Pulses(pulse / revolution) If unspecified, rpm when delivered. Input Input Impedance RD, FK Series, H5 Series (AIRPAX o.) About 5 kω Zerospeed Relay Input Voltage Range 300 Vpk-pk or less Hysteresis an be setup within the range 0 to 50 rpm ( rpm Increments) Min. Input Pulse Width 5 µs Z : Min. Indicated frequency 0.0 Hz Z2 : If unspecified, rpm when delivered. No. of Input Pulses to 20 pulse Trigger Mode Manual Trigger Dimension(Model RD,FK) D B A D A D B External ontact Input ontact Type : Dry contact ontact for External Reset ontact for Lamp Test ontact for Zerospeed BYPASS Digital Indicated Accuracy ±(0.003% of rdg. + digit) at 25 ±(0.03% of rdg. + digit) at 0 to 60 Note: A should not be flat. Make the curve along a concentric circle. Input A= mm B= mm = mm D= mm Dimension of Target Recommended RD-05A FK-202F A 6 B 7 2.5 (mm) D 6 Set Gap Setup Value(mm).0 to.5 onversion Accuracy Pulse Output Voltage or current output proportional to the range 0 to 00rpm. to 5VD (Output Impedance : 250Ω) 4 to 20mAD (Max. Load Resistance : 600Ω) Output Point : point ±0.5% of F.S. at 25 ±2.0% of F.S. at 0 to 60 Pulse Output : Shaped pulse signal is output via a buffer amplifier. Signal Level : - to +V(P L ), +4 to 6V(P H ) Output Impedance : About 00Ω -24VD±V, 20mA (RD, FK specified) +2VD±V, 50mA (H5 specified) (Provided 9V to 27 VD from the bass-line in the s Instrument Rack) Zerospeed ontact Output Point : Z : 2 points Temperature Range Operating Temperature : 0 to 60 Output : Z2 : 2 points Storage Temperature : -30 to +85 : NOT-OK : point Relative Humidity : 20 to 95%RH (noncondensing) ontact apacity : Resistance Load : 250VA, 5 A Face Plate Finish Munsell N-.0 (equiv.) : 30VD, 5A Mass max. 2.0kg ontact Type : ontact, Dry ontact E Marking onform to E requierements when MP-P2 is used for power unit. ondition Z ontact Z2 ontact Not-OK ontact Indication After PU Abnormality Detection 0 V (0mA) Input Abnormal Detection Input Abnormal Indication 0 V (0mA) Zerospeed Detection Zerospeed Detection Indication Measured Value On-line Test (ontact Output Mode) On-line Test Indication Test Value On-line Test (ontact ontrol Mode) On-line Test Indication Test Value Unit Removal All ontacts Open All ontacts Open All ontacts Open 0 V (0mA) : Information Sent : Output ontrol : No relation ship 39804E2.0 Revised : Jan. 202

MODEL MP-T THRUST UNIT SPEIFIATIONS Model Spec. ode upon delivery/add l Spec. ode ( not requested, leave blank ) MP-T- 0 - Monitor Range Input Signal Frequency Response Polality* -0.5mm to 0 to +0.5mm VK-202A,FK-202F 0 D to 0.5Hz(-3dB) Direct 4 to 20mAD 0 Not Provided 2 -mm to 0 to +mm 2 VK-452A,FK-452F 2 Reverse 2 to 5VD Provided 3-2mm to 0 to +2mm 3 VK-302P Note) * 4-25mils to 0 to +25mils 4 VK-602P 5-40mils to 0 to +40mils 6-80mils to 0 to +80mils Note) When using Monitor Range 2 (-.0 to 0 to +.0mm) or 5 (-40 to 0 to +40mils), combined with input signal and Intrinsically Safe Explosion Proof onstruction, the OK Alarm Setup Point falls within the range. Therefore, use the monitor within 90% of the range. - - - /EX Polality Indication and Recorder output Toward sendor Away from sensor Direct Increase Decrease Reverse Decrease Increase Alarm Reset Alarm Reset Alarm Reset Alarm Delay Time Alarm Delay Time Sensitivity System Group*2 (TRP) (ALT) (NOT-OK) (TRP) (ALT) (NOT-OK) (TRP) (ALT) correction 0 Auto-Reset 0 Auto-Reset 0 Auto-Reset Normally 0.sec. 0. sec. A TIIS 0 Self-Hold Self-Hold Self-Hold De-energized 0 Normally De-energized 0 Normally De-energized 2 sec. 2 sec. 2 B 2 FM Normally Normally Normally 3 2 sec. 3 2 sec. 3 4 SA Energized Energized! Danger In case the Machine Protection System is designed to be used with this unit, use the redundant system consisting of three units (corresponding to 2 out of 3). For highest reliability, use other meters or machinery protection equipment to design the system. In case the machine protection is performed using a single meter, and that meter is experiencing a problem, it may cause severe injury or damage to the equipment. Alarm Set Point HH : H : L : LL : If unspecified, H-DANGER : 00% of delivered monitor range. H-ALERT : 90% of delivered monitor range. L-ALERT : 0% of delivered monitor range. L-DANGER : 0% of delivered monitor range. s an be setup within the range 0 to 50% of F.S. (0% Increments) Setup value : Alarm ontact Output Output Point : TRP : 2 points : ALT : 2 points Energized 4 3 sec. 4 3 sec. 5 ATEX 5 5 sec. 5 5 sec. 7 NEPSI Measured Value LED Digital meter with 5 digits (7 segnents) Shift Key Select Indicator SHIFT : (Red LED) Input VK-202A, FK-202F, VK-302P, VK-452A, FK-452F, VK-602P Input Impedance About 50kΩ External contact Input ontact Type : Dry ontac t ontact for External reset ontact for Lamp Test ontact for TRP Alarm BYPASS Zero Shift Adjustable within 0 to 00% of monitor range Digital Meter ±.0% of F.S. at 25 ±0.5% of F.S. at 25 onversion Accuracy ±2.0% of F.S. at 0 to 60 Note) *2 hose the same group code on each unit used for a system as "2 out of 3" or "2 out of 2" in a same rack. Voltage or current output proportional to monitor range. to 5VD (Output Impedance : 250Ω) 4 to 20mAD (Max. Load Resistance : 600Ω) Output Point : point -24VD±V, 20mA : NOT-OK : points (Provided 9V to 27 VD ontact apacity : Resistance Load : 250VA, 5A from the bass-line in the : 30VD, 5A Instrument Rack) ontact Type : ontact Dry ontact Temperature Range Operating Temperature : 0 to 60 Alarm Set Point 4 points (HH, H, L, LL) Storage Temperature : -30 to +85 Alarm Set Range -0 to +0% of monitor range Rslative Humidity : 20 to 95%RH (noncondensing) Alarm Set Accuracy ±.0% of F.S. or less Face Plate Finish Munsell N-.0 (equiv.) Alarm Set Repeatability ±0.% of F.S. or less Mass max.2.0kg Alarm Output point (NOT-OK) E Marking onform to E requirements when MP-P2 is used for power supply unit. ondition TRP ontact ALT ontact Not-OK ontact Indication After PU Abnormality Detection 0 V (0mA) Input abnormal Detection Input Abnormal Indication Measured Value TRP Information Sent TRP Indication Measured Value ALT Information Sent ALT Indication Measured Value On-line Test (ontact Output Mode) On-line Test Indication Test Value On-line Test (ontact ontrol Mode) On-line Test Indication Test Value Unit Removal All ontacts Open All ontacts Open All ontacts Open 0 V (0mA) : Information Sent : Output ontrol : No relation ship 309805E.9 Revised : Dec.2009

SPEIFIATIONS MODEL MP-P POWER SUPPLY UNIT Voltage Regular, Backup 85 to 264VA Regular 2 24VD 2 Backup 3 48VD 4 0VD Indicator OK Indicator : Green LED Output Alarm ontact Output ontact Type : P-OK (to supply power to bassline ontact apacity : 250VA, 5A in Instrument Rack) : 30VD, 5A Insulation Resistance ontact Type : contact Dry contact Normally energized Alarm Reset ontact Life Protective onstruction Model Spec. ode upon delivery / Add l Spec. ode ( not requested, leave blank ) Auto-reset 00,000 times or more (rated load) Plastic seal MP-P Regular : 26V± VD Backup : 24V±VD Between power supply & GND : 00M or more at 500VD Between power supply & alarm contact : 00MΩ or more at 500VD Between GND & alarm contact : 00MΩ or more at 500VD Dielectric Strength Between power supply & GND MP-P : 2,000VA, min. MP-P2 : 2,000VA, min. MP-P3 : 2,000VA, min. MP-P4 :,500VA, min. Power onsumption MP-P : 20VA or less MP-P2 : 00W or less MP-P3 : 00W or less MP-P4 : 00W or less Temperature Range Operating Temperature : 0 to 60 Storage Temperature : -30 to +85 Relative Humidity : 20 to 95%RH (non-condensing) Finish Panel : Munsell N-.0 (equiv.) Mass Max. 2.0kg E Marking Only as for MP-P2. 39806E.3 Revised : Apr.2004

SPEIFIATIONS MODEL MP-W INSTRUMENT RAK Model Spec. ode upon delivery/add l Spec. ode( not requested, leave blank ) MP-W - No. of Mounted Units * ombination Max. 3 Units 0 D A 2 Max. 6 Units D D 2 A A * Unit is not included. Input for Operation External Reset (normally open) Lamp Test (normally open) Start-up Timer (short circuit between terminals: START; open between terminals: STOP) TRP / Zerospeed Bypass (normally open) ontact Type : Dry contact Temperature Range Operating Temperature: 0 to 60 Storage Temperature: -30 to +85 Relative Humidity: 20 to 95%RH (non-condensing) Finish Rack: Munsell N-.0 (equiv.) Weight MP-W: max.7kg MP-W2: max.0kg E Marking onform to E requierements when MP-P2 is used for power unit. 39807E.4 Revised : Dec.202